Housing Urban and Rular Development Government Departments Closing in 11 days TDR #58072456

Tender For Special Repairs To Leaky Roof, Doors, Windows, Flooring, Water Supply And Sanitary Arrangements In Health Sub Centre Building At Alanda In Thoothukudi District.

Issued by Government Departments · Tuticorin, Tamil Nadu
Tender Value
7.60 Lakhs
Estimated cost
Bid Submission
29 Oct 2026
11 days left
EMD
7600
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Tuticorin → Tamil Nadu
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Special Repairs To Leaky Roof, Doors, Windows, Flooring, Water Supply And Sanitary Arrangements In Health Sub Centre Building At Alanda In Thoothukudi District.

BOQ

Name of Work:- Special repairs to leaky roof, doors, windows, flooring, water supply and sanitary arrangements in Health Sub Centre building at Alanda in Thoothukudi District.
Sl. No. Item Description
1Dismantling and clearing away and carefully stacking the materials useful for reuse for any thickness of walls
2Weathering course with Machine pressed tiles
3Clean remoc\val of cement plaster
4Renewal of weathering course in brick jelly lime concrete using broken brick jelly of size 20mm uniform gauge in pure slaked lime (no crushed stone sand to be used) to the proportion of brick jelly to lime being 32:12.5 by volume and laid over the RCC roof slab in a single layer of required slope and finished by beating the concrete with wooden beaters of approved pattern, keeping the surface constantly wet by sprinkling lime jaggery water, etc., complete as per standard specification and as directed by the deparmental officers.
5Refinishing the top of roof with one course of machine pressed tiles of size 230mm x 230mm x 20 mm to 18mm of approved quality set in Cement Mortar 1:3 (One Cement and Three Crushed stone Sand) 12mm thick mixed with water proofing compound conforming to ISS at 2% by weight of cement used and the joints pointed neatly to full depth of tiles with the same cement mortar mixed with red oxide and water proofing compound including curing etc., complete complying with standard specification and as directed by the departmental officers
6Renewal and refixing in position best approved of BIS quality of PVC rain water down fall pipes having a working pressure of 4 kg/cm2 including cost of necessary PVC shoe, PVC bend, cast iron gratings of required diameter and special clamps, brass screws, nails etc., and fixing of cast iron gratings at junction of parapet and the RCC roof slab including finishing neatly etc., complete. The rate shall be inclusive of cost of removable of iron grating. The PVC pipe shall be fixed in wall with Special type of 'U' clamp at the centre of the pipe line in addition to those for more than 3m pipe length etc., complete complying with standard specification.
7110mm dia PVC rain water down fall pipe
8Renewal of special ceiling plastering and finishing the exposed surface of all RCC items of work such as slabs, beams, sunshades, facia, canopy slab, staircase waist slab, landing slab etc., with Cement Mortar 1:3 (One Cement and Three Plastering Sand) 10mm thick including mortar plasticizer at 200ml per 50Kg of cement used , hacking the surfaces and curing, etc., in all floors complying with standard specification and as directed by the departmental officers
9Renewal of Brick work in Cement Mortar 1:5 (One cement and Five crushed stone sand) using best quality Fly ash Brick of size 230x110x70mm with class designation of 7.5 conforming to IS 13757-1993 or IS 12894-2002 for foundation and basement including Cost of Mortar Plasticizer, curing, etc., complete complying with standard specification and as directed by the departmental officers. Brickwork shall be done as per IS 2212-1991 adopting English Bond generally.other type of bond shall be done as directed by the Executive Engineer in charge.
10In Groound floor
11Replastering with Cement Mortar 1:5 (One cement and Five Plastering sand),12mm thick in all floors including mortar plasticizer at 200ml per 50Kg of cement used curing etc. complete complying with standard specification and as directed by the departmental officers.
12Renewal and refixing Solid PVC door shutters using 19 Gauge 19mm MS square tubes for styles and outer frames, 15mm MS square tubes for top, lock and bottom rails. The steel tubes shall be covered with 5mm thick solid PVC sheets. Shutter using 5mm thick solid PVC sheets for panelling shall rigidly fixed in position including necessary furniture and fittings. The over all size of styles shall be 50mm x 30mm. The over all size of top rail, Lock rail and bottom rail shall be 75mm x 30mm. The over all size of frames shall be 50mm x 45mm, with suitable rebate for housing the shutter with frame.
13Renewal and refixing in positon Indian Water Closet (Oriya type) of size 580 x 440mm white glazed earthern ware of approved quality and brand with \\"P\\" or \\"S\\" trap conforming to BIS with crushed stone sandcushion and forming flooring alround the closet using 40mm broken brick jelly in lime concrete 1:2:5 (One lime, Two crushed stone sandand Five brick jelly) 100mm thick and finishing the top to the required slope and including giving necessary connection to PVC pipes (including the cost of 110mm dia PVC pipe for a length of 600mm) by dismantling brick masonry wall / reinforced cement concrete roof / floor slab and making good the dismantled portion to the original condition with leakages etc., complete complying with standard specifications and as directed by the departmental officers. (The water closet should be got approved by the Executive Engineer before use on works).
14Renewal and refixing in position white glazed European Water Closet of best quality and approved make with 100 mm “P” or “S” trap connecting with PVC pipe of 110mm dia, double flapped rigid PVC black seat and seat cover with CP brass hinges including cost of white cement, cement for packing, spun yarn,teak wood plugs, brass screws, etc., including supplying and fixing 10 litres capacity PVC low level flushing tank with a pair of CI brackets, etc., complete with all fittings such as 15mm brass ball valve with polythene float with brass handle, union, coupling connected by means of 40mm white PVC flush hand using Indian adopter joint including all internal fittings such as 15mm brass connections, 15mm GM wheel valve, 15mm brass nipple (2 Nos.), 15mm nylon connection, TW plugs, screws and also giving necessary connection to the PVC pipe including cost of 600mm length of 110mm dia PVC pipe and painting the CI brackets with 2 coats of approved paint over one coat of red oxide primer, dismantling the masonry and re-doing the dismantled masonry to original condition etc. complete complying with standard specifications. (The EWC and flushing tank with all accessories should be got approved by the Executive Enginer before use on works)
15Renewal and refixing in position 15mm dia brass CP screw down tap (heavy duty) of approved make conforming to BIS specifications and quality including cost of shellac, thread, etc., complete complying with standard specification and including cutting and threading wherever necessary. (Taps should be got approved by the Executive Engineer before use on the works)
16Renewal and refixing fine polished cuddapah slab of 20/30mm thickness for cup-board arrangements including laying to correct alignment with necessary cement mortar and black powder etc, complete complying with standard specification and as directed by the departmental officers
17Providing Cup-board Shutter with frame using termite / water proof plywood of 19mm thick over which laminated sheet of 0.8mm thick fixed inside the shutter and 1mm thick fixed in the outside of the shutter using fevicol along with necessary furniture fittings, such as, hydralic hinges, tower bolt, handles, multi purpose locks etc., as directed by the Departmental Officers. The design pattern, water proof plywood, laminate sheet and other materials should be got approved from the Executive Engineer befoe use on work.
18Renewal and refixing best quality PVC soil pipes of various dia having 6 kg / sq.cm. pressure BIS mark and providing leak proof joints using PVC adhesives including fixing to the wall with special PVC / MS clamp, teak wood plugs, brass screws, etc., and making connection to all sanitary fittings, dismantling masonry / RCC works wherever found necessary and making the good dismantled portion to the original condition, including testing for any leakages, etc., complete complying with standard specifications. (The PVC pipes should be got approved by the Executive Engineer before use on works). Below Ground Level
19110mm dia PVC soil pipe
2075mm dia PVC soil pipe
21Renewal and refixing best quality PVC soil pipes of various dia having 6 kg / sq.cm. pressure BIS mark and providing leak proof joints using PVC adhesives including fixing to the wall with special PVC / MS clamp, teak wood plugs, brass screws, etc., and making connection to all sanitary fittings, dismantling masonry / RCC works wherever found necessary and making the good dismantled portion to the original condition, including testing for any leakages, etc., complete complying with standard specifications. (The PVC pipes should be got approved by the Executive Engineer before use on works). Below Ground Level
2225mm dia PVC pipe
2320mm dia PVC pipe
24Renewal of flooring with Antiskid Self Designed Colour Ceramic tiles of size 305 x 305 x 6mm and variety conforming to IS 15622 laid over cement mortar bed of 20 mm thick in cement mortar 1:3 (One Cement and Three crushed stone Sand) with required Cement Slurry and Mortar Plasticizer including cutting the tiles to the required size with special cutter wherever necessary, laying in position and pointing with Water Resistant Tile Epoxy Grout at the rate of 0.27 Kg. / sq.m. etc., complete complying with standard specification and as directed by the departmental officers. (The make and brand of the tiles should be got approved by Executive Engineer before use on works)
25Renewal of the floor with best quality Double charged Vitrified Tiles of size 600 x 600 x 8 mm and variety conforming IS 15622 with water absorbtion less than 0.08% of approved colour and shade laid over cement mortar bed of 20mm thick in cement mortar 1:3 (one cement and three crushed stone sand) with required Cement Slurry and Mortar Plasticizer in all floors and the top pointed with Water Resistant Tile Epoxy Grout etc., complete complying with standard specification and as directed by the departmental officers. (The make and brand of the tiles should be got approved by Executive Engineer before use on works)
26Redadooing walls with 300mm x 450mm x 8mm best approved quality, colour glazed tiles conforming to IS 15622 of following sizes in Cement Mortar 1:2 (One Cement and Two crushed stone sand),10 thick with Mortar Plasticizer and pointing the joints with Water Resistant Tile Epoxy Grout at the rate of 0.27 Kg. / sq.m. neatly in all floors, curing, etc., complete complying with standard specification and as directed by the departmental officers.(The make and brand of the tiles should be got approved by Executive Engineer before use on works)
27Painting two coats of newly plastered wall surface with ready mixed plastic Interior emulsion paint of first class quality and of approved colour over a priming coat including thorough scrapping, clean removal of dirt, and including necessary plaster of paris putty, wherever required etc., complete complying with standard specification.
28Repainting Old Plastered Wall Surface with Two finishing coats of ready mixed (Interior Emulsion) of approved quality and colour over the existing wall in all floors etc., complete complying with standard specification and as directed by the departmental officers. (The make, quality and colour of paint should be got approved by the Executive Engineer before use on works.)
29Repainting Old Plastered Wall Surface with Two finishing coats of ready mixed (Exterior Emulsion) of approved quality and colour over the existing wall in all floors etc., complete complying with standard specification and as directed by the departmental officers. (The make, quality and colour of paint should be got approved by the Executive Engineer before use on works.)
30Repainting Old iron works such as steel doors, windows, ventilators, window bars, balustrades etc., with one coat of best approved first quality and colour of synthetic enamel paint in all floors etc., complete complying with standard specification and as directed by the departmental officers. (The make, quality and colour of paint should be got approved by the Executive Engineer before use on works.)
31Repainting Old wood work with One coat of synthetic enamel ready mixed paint of approved quality and colour in all floors etc., complete complying with standard specification and as directed by the departmental officers.(The make, quality and colour of paint should be got approved by the Executive Engineer before use on works.)
32Drilling of 6\\" dia vertical bores in hard rock areas to any required depth as directed by the departmental officers. The rate is inclusive of assembling the equipment in the point as selected, drilling bore, labour charges for inserting the casing pipe if necessary and also transportation charges of the rig and supporting vehicle to the bore point etc., complete complying with standard specification.
33Supplying and erecting of 160 mm C.S dia heavy duty PVC casing pipe as per I.S. 12818 / 1992 with collars including provision of guides for every 15 m. interval for bore well in the drilled hole etc., complete as directed by the Executive Engineer including cost of materials and labour. The rate is exclusive of erection charges of casing pipes in to borewell. (Plain)
34Supplying and fixing of suitable PVC End cap 160mm dia etc., complete complying with standard specifications. PVC End cap should be got approved by the departmental officers before use on work.
35Supplying laying and jointing HDPE pipes class - V-1MP a with working pressure of 10 kg./cm2 of approved quality and best quality conforming to ISS and with ISI mark of following sizes including cutting threading and fixing GI specials but including cost of such specials and fixing into Bore well for suction line, air pipe etc., complete complying with standard specification.
3625 mm dia HDPE pipe
37Renewal and erecting and commissioning 1.00 HP Monoblock motor with accessories conforming to ISI Std., assembling over the clamp in dismantling brick masonry fixing bed clamp with angle purline etc, in to the wall redoing dismantling portion neatly including labour for fixing the motor with proper alignment to the suction, delivery pipe etc., complete complying with standard specification and as directed by the departmental officers.
38Renewal and refixing in position of white coloured P.V.C water storage tank-of best approved quality and brand ofsuper thick with the capacity of 500 Litres with accessories including giving necessory connections etc., complete as directed by the departmental officers. ( The P.V.C. water storage tank should be got approved by the Executive Engineer before use on works.)
39Renewal and refixing in position best quality and approved make Indian made white glazed earthernware wash hand basin of size 550 x 400mm (without pedestal) with a pair of cast iron brackets, including cost 15mm dia brass CP pillar tap, 32mm dia \\"B\\" class GI waste pipe with rubber plug and chain, 15mm dia GM wheel valve, 15mm brass nipple, 15mm dia nylone connection, 32mm dia CP brass waste coupling including fixing of wash basin using CI brackets on to the wall in position with TW plugs and screws, rubber washers, white lead and giving necessary water supply connection and painting the brackets with two coat of painting over a priming coat of anti-corrosive paint including testing for leakages etc., complete complying with standard specification and as directed by the departmental officers. (The wash hand basin and specials should be got approved by the Executive Engineer before use on works).
40GST Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 58072456
AUTHORITY Government Departments
TENDER VALUE 7.60 Lakhs
LAST DATE 29-10-2026
Authority
Authority Name Public Works Department
Work Description Tender for Special Repairs To Leaky Roof, Doors, Windows, Flooring, Water Supply And Sanitary Arrangements In Health Sub Centre Building At Alanda In Thoothukudi District.
Basic Detail
Tender No ETender 5(2)/EE 2026 27 Dated 08.10.2026
Bidding Type Tender
Location
City Tuticorin
State Tamil Nadu
Key Dates
Publish Date 15 Oct 2026
Submission Date 29 Oct 2026
Open Date 30 Oct 2026
Finance
Tender Value 7.60 Lakhs
Tender Fee Ref. Documents
EMD 7600
Exemption Not Available
Document List
BOQ_858705.xls
fc0c9a7e-09a4-490c-9539-517999683534.html
TdAlanda.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Oct 15, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Oct 29, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 11 days
Oct 30, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 12 days

Tender Documents

Download All (ZIP) ↓
xls

BOQ_858705.xls

html

fc0c9a7e-09a4-490c-9539-517999683534.html

pdf

TdAlanda.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender