Tender For Supply Installation Testing and Commissioning of New, Latest-Technology Precision Air Conditioning Units, Replacing The Old Pcpa Units Installed At The Saif And The Data Center Of Csir-Cdri, Lucknow.
Tender Value
97.31 Lakhs
Estimated cost
Bid Submission
05 Nov 2026
20 days left
EMD
1.94 Lakhs
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Lucknow → Uttar Pradesh
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Supply Installation Testing and Commissioning of New, Latest-Technology Precision Air Conditioning Units, Replacing The Old Pcpa Units Installed At The Saif And The Data Center Of Csir-Cdri, Lucknow.
BOQ
| Sl. No. | Item Description |
| 1 | Supply, installation, testing and commissioning including lifting and shifting of energy efficient floor mounted, bottom discharge, air cooled DX type Microprocessor based precision package airconditioning refrigerant charged indoor and out door unit , equiped with advanced technology to precise control of tempreture and relative humidity.The Indoor unit shall comprise of digital/Inverter scroll compressor, corrossion resistant fans with EC motors, Evaporator DX copper cooling coil with hydrophilic coating, microprocessor controllers, electronic expansion valve, driers, EU4/G4(with 90% efficiency down to 10 micron size particle)air filter, suction and discharge piping, liquid receiver, internal power and control wiring, humidifier, BMS compatible, air reheating heaters for dehumidification, HP/LP cutouts, power and control contactors, water leak detectors and other electrical accessories complete in all respect.The unit should suitable for operation on 415 Volts, 50 Hz, 3 Phase, AC supply.Each unit should be having individual display panel, which shall display date, time, actual & set values, operating conditions, signal faults, collective faults and machine service alarm to reduce the down time and unit memory shall hold the recent events with ID number, time and date for each event.The outdoor condenser unit shall comprise of condenser fans,condenser cooling coil (copper coil with aluminium fins),EC motor/ motor with fan speed controller, isolater switch. The units shall be selected (computerized selection sheet must be enclosed) on the basis of following parameters:i) Not Less then 8.5 TR Cooling Capacity @ 7944 CMH or moreii) Return Air Selection at : ≤ 25°C / 50 % RH of return air@ ≥ 48°C ambient temp.iii) Temp/RH Control : Set point for temp. ± 1°C & Set point for RH ± 5%(maximum). . |
| 2 | Supply and fixing of interconnecting discharge line with18 SWG copper piping between indoor & outdoor unit. The copper piping will be duly sleeves insulated inside the room. |
| 3 | Supply and fixing of interconnecting liquid line with18 SWG copper piping duly sleeves insulated between indoor & outdoor unit. The copper piping will be duly sleeves insulated inside the room. |
| 4 | Supply and fixing of MS outdoor stand duly painted with anti-corrosive paint along with vibration isolation pad, bolts, fittings & accessories complete in all respect. |
| 5 | Supply and fixing of MS indoor stand duly painted with anti-corrosive paint along with vibration, bolts, fittings & accessories. |
| 6 | Supply and laying of interconnecting 3 core x 2.5 sqm PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade armered copper cable between indoor & outdoor unit. |
| 7 | Supply and fixing of motorized air damper with actuator and wiring complete in all respect. |
| 8 | Supply and fixing of drain water connection pipe having size of 40mm with insulation, fittings & accessories complete in all respect.. |
| 9 | Dismantling of old PAC and shitting at respective locations in premises suggested by the Engineer In cahrge. |
| 10 | Supplying and installating following size of perforated hot dipped galvanised Iron cable tary (Galvanisation thickness not less than 50 micron) with perforation of not more than 17.5%, in convenient section s, joined with connectors on surface with GI angle, GI bolts& nuts, fastener etc as required. |
| 11 | 300 mm width x 50 mm depth x 1.6 mm thickness |
| 12 | Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required. |
| 13 | Supply and laying of humdifier piping inlet connection with 25 m.m. UPVC pipe and isolation ball valve etc. complete in all respect.. |
| 14 | Modification in existing supply and reurn air ducting connections with new duct with 0.80 mm thick GSS sheet of required size complete in all respect. |
| 15 | Supplying and fixing of 19 m.m. thickness duly laminated aluminium foil of mat finish closed cell nitrile rubber (Class O) insulation on existing duct after applying suitable adhesive for nitrile rubber.The joints shall be sealed with 50 mm wide and 3 mm thick self adhesive nitrile rubbe tape insulation complete as per specification and as requried. |
| 16 | Sequencing of PAC units with all required material. |
| 17 | Comprehensive annual maintenance charges for the item no. 1.11 after comletion of defect liability period of one year . |
| 18 | For Ist Year |
| 19 | For IInd year |
| 20 | For IIIrd Year Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Oct 15, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedNov 05, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 20 daysNov 06, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 21 daysTender Documents
Download All (ZIP) ↓
Disclaimer