Defence Statutory Bodies & Commissions/Committees Closing in 6 days TDR #58061098

Tender For Repair/Maintenance Of Lt Distribution Cables, Lt Panels, Lt Cable Joints & Switch Gears Connected Misc Works At repair renovation 3, Sub Stations Los,Santacruz ,765 Su & Hq Mao Under Afs Mumbai Under Ge Af Thane

Issued by Statutory Bodies & Commissions/Committees · Thane, Maharashtra
Tender Value
32 Lakhs
Estimated cost
Bid Submission
03 Nov 2026
6 days left
EMD
64000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Thane → Maharashtra
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Repair/Maintenance Of Lt Distribution Cables, Lt Panels, Lt Cable Joints & Switch Gears Connected Misc Works At repair renovation 3, Sub Stations Los,Santacruz ,765 Su & Hq Mao Under Afs Mumbai Under Ge Af Thane

BOQ

Name of Work:- Repair/Maintenance of LT distribution Cables, LT panels, LT cable joints & Switch Gears connected misc works at RR 3, Sub stations Los,Santacruz ,765 SU & HQ MAO under AFS Mumbai under GE AF Thane
Sl. No. Item Description
1Excavation in trenches not exceeding 1.5 m wide and not exe 1.5 M in depth and getting out in soft/loose soil complete all as specified and directed by Engr-in-Charge.
2Returning filling in including spreading leveling, watering and well ramming in layers not exe 25 cm each layer complete all as specified and directed by Engr-in-Charge.
3Removing excavated material to a distance not exe 50 M and depositing where directed not exceeding 1.50 M above the starting point complete all as specified and directed by Engr-in-Charge.
4Supply spreading in trenches dry crushed Stone sand for cable protection and punning down gently by hand complete all as specified and directed by Engr-in-Charge.
5Supply and laying unreinforced precast concrete cable cover factory made embossed the mark “LT CABLE” class LV type1 flat size 250x150x40 mm laid in trenches complete all as specified and directed by Engr-in-Charge.
6Supply and fix Galvanized iron steel tubing Light grade of 80mm bore with all fittings as required at site and laid in floors/trenches as in cable protection complete all as specified and as directed by Engr-in-charge
7All As per Item Sr No -8 but of size of size 50mm dia bore complete all as specified and directed by Engr-in-Charge.
8Dismantling and Taking down L.T. under ground armored PVC insulated and PVC sheeted heavy duty 1100 Volts grade under ground cable of any size complete all as specified and directed by Engr-in-Charge.
9Supply and laying in the ground/ saddling through the wall/trenches of cable XLPE Insulated armoured, heavy duty electric power cables (heavy duty) 1100 Volts grade, cross sectional area with stranded aluminium conductor of size 10 sq mm 2 Core complete all as specified and directed by Engr-in-Charge.
10All As per Item Sr No -9 but of size of size 10 sq mm 4 Core complete all as specified and directed by Engr-in-Charge.
11S&F in repair 25mm Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe or for unions and fixed complete all as specified and directed by Engr-in-Charge.
12Disconnecting existing tanks, of capacity exc 500 ltr but n. exc 1000 ltrs setting aside (or lowering if required) for repairs, cleaning, etc. and hoisting if required reconnecting and re-fixing in position. (Cleaning repairing, etc. measured separately) complete all as specified and directed by Engr-in-Charge.
13All As per Item Sr No -9 but of size of size 25 sq mm 3.5 Core complete all as specified and directed by Engr-in-Charge.
14All As per Item Sr No -8 but of size of size 35 sq mm 3.5 Core complete all as specified and directed by Engr-in-Charge.
15All As per Item Sr No -9 but of size of size 50 sq mm 3.5 Core complete all as specified and directed by Engr-in-Charge.
16All As per Item Sr No -9 but of size of size 70 sq mm 3.5 Core complete all as specified and directed by Engr-in-Charge.
17M&L Earthing complete with galvanised steel earth plate electrode60 60cm. 6mm thick, buried directly in ground (earth pit not lessthan 2.25 metres deep below groundlevel) with top edge of the plate not less'than 1.5 metres below normal ground level, connected to galvanised iron strip 32 x 6 mm as a earthing lead by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electricalplate No. 3 connected to earthing test point all as specified or indicated including testing on completion Note : Amount Includes all Earth work PCC ,earth, Pit, CI CoverFunnel ,wire mesh, Copper Lugs, GI Protection pipe etc completed all as specified and directed by Engr-in-Charge.
18M & L Earth continuity conductor or mainearthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as 32x6mm galvanised iron strip completed all as specified and directed by Engr-in-Charge.
19M & L Earth continuity conductor or mainearthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as 20x3mm copper strip complete all as specified and directed by Engr-in-Charge.
20Material and Labour scrapping to existing LT Panels/ Feeder pillar boxes of out side surfaces and applying two coats of synthetic enamelled paint on out side/ exposed surfaces of LT panels and LT feeder pillar boxes and including cleaning of Metering equipement system,Indication lamps,selector switches etc complete all as specified and directed by Engr-in-Charge.
21Material and Labour for repairing of LT Panel of not exc of sizes 2.5 Mtr x 2 Mtr x 0.80 Mtr doors/shuttering to welding and bracing of hinges, tinkering, and replace worn out rusted unserviceable doors/compartment shutters front sides and back side lock system including replace worn out rubber gaskets/feeding of compartment doors/shutters, decorbonising of all cable terminals, Busbars (R,Y,B &N) aluminium/copper cleaning inside of panel housing with help of air belower heavy duty complete all as specified and directed by Engr-in-Charge.
22Material and Labour for repairing of LT Panel of not exc of sizes 2 Mtr x 1.5 Mtr x 0.80 Mtr doors/shuttering to welding and bracing of hinges, tinkering, and replace worn out rusted unserviceable doors/compartment shutters front sides and back side lock system including replace worn out rubber gaskets/feeding of compartment doors/shutters, decorbonising of all cable terminals, Busbars (R,Y,B &N) aluminium/copper cleaning inside of panel housing with help of air belower heavy duty complete all as specified and directed by Engr-in-Charge.
23Material and Labour for repairing of feeder pillar box of not exc of sizes 2 Mtr x 1.5 Mtr x 0.80 Mtr doors/shuttering to welding and bracing of hinges, tinkering, and replace worn out rusted unserviceable doors/compartment shutters front sides and back side lock system including replace worn out rubber gaskets/feeding of compartment doors/shutters, decorbonising of all cable terminals, Busbars (R,Y,B &N) aluminium/copper cleaning inside of panel housing with help of air belower heavy duty complete all as specified and directed by Engr-in-Charge.
24S&F in repair LED indication lamp for indication of (R,Y,B) 230 Volts including connections and taking out unserviceable indication Lamp complete all as specified and directed by Engr-in-Charge.
25S&F in repair Volt meter 0-500 Volt digital type including connections and taking out unserviceable Volt meter complete all as specified and directed by Engr-in-Charge.
26S&F in repair Ampere meter 0-400Amps digital type including connections and taking out unserviceable Ampere meter complete all as specified and directed by Engr-in-Charge.
27S&F in repair Selector switch for Volt meter 4 way Knob type (0FF, RB,RY,BY) including connections and taking out unserviceable selector switch complete all as specified and directed by Engr-in-Charge.
28S&F in repair Selector switch for Amp meter 4 way (0FF,R,Y,B) Knob type including connections and taking out unserviceable selector switch complete all as specified and directed by Engr-in-Charge.
29Supply and fix in repalcement of standard copper conductor of size 10 Sqmm single core for internal connection inside feeder piller or panel from connector MCCB or MCBS or Contactor all as per existing including copper lugs for cable termination at both ends complete all as specified and directed by Engr-in-Charge.
30Supply and fix cable jointing kit heat shinkable straight through outdoor type suitable for LT cable 1100 volt grade cables of size up to size 4 core 25 Sqmm / 3.5 core 25 sqmm cable size all as per site requirement complete all as specified and directed by Engr-in-Charge.
31All As per item no 30 above but of size 3.5 core 35 Sqmm to 3.5 core 70 Sqmm complete all as specified and directed by Engr-in-Charge.
32All As per item no 30 above but of size 3.5 core 95 Sqmm to 3.5 core 120 Sqmm complete all as specified and directed by Engr-in-Charge.
33All As per item no 30 above but of size 3.5 core 150 Sqmm to 3.5 core 180 Sqmm complete all as specified and directed by Engr-in-Charge.
34Supply and fix aluminum cable lugs suitable for LT cable 1100 volt grade cables of size up to size 4 core 25 Sqmm / 3.5 core 25 sqmm cable size all as per site requirement complete all as specified and directed by Engr-in-Charge.
35All As per item no 34 above but of size 3.5 core 35 Sqmm to 3.5 core 70 Sqmm complete all as specified and directed by Engr-in-Charge.
36All As per item no 34 above but of size 3.5 core 95 Sqmm to 3.5 core 120 Sqmm complete all as specified and directed by Engr-in-Charge.
37All As per item no 34 above but of size 3.5 core 150 Sqmm to 3.5 core 180 Sqmm complete all as specified and directed by Engr-in-Charge.
38Supply and fix cable double compression cable glands suitable for LT cable 1100 volt grade cables of size up to size 4 core 25 Sqmm / 3.5 core 25 sqmm cable size all as per site requirement complete all connnected accessories all as specified and directed by Engr-in-Charge.
39Supply and fix in repalcement of in replacement 4 core 10sqmm copper flexible cable for connection of high bay light fittings inside the hanger with saddles spacers and screw for securing flexible cable including connection complete all as per site requirement with Necessary scaffolding should be arrange by contactor for fixing of cable and fittings at height upto 30 meters including arrangement of Airport Passes for labour and material from Air Port Authority of India complete all as specified and directed by Engr-in-Charge.
40Supply and fix in repalcement of LED flood light fitting 120 Watts Pressure die cast aluminium housing with surge protection, heat resistant toughened glass with frame, IP66 protection better optics for uniform distribution make or equivalent of complete all as specified and directed by Engr-in-Charge.
41Supply and fix in repalcement of LED flood light fitting 70 Watts Pressure die cast aluminium housing with surge protection, heat resistant toughened glass with frame, IP66 protection better optics for uniform distribution make or equivalent of complete all as specified and directed by Engr-in-Charge.
42All As per item no 39 above but of size 3.5 core 35 Sqmm to 3.5 core 70 Sqmm complete all as specified and directed by Engr-in-Charge.
43All As per item no 40 above but of size 3.5 core 95 Sqmm to 3.5 core 120 Sqmm complete all as specified and directed by Engr-in-Charge.
44All As per item no 41 above but of size 3.5 core 150 Sqmm to 3.5 core 180 Sqmm complete all as specified and directed by Engr-in-Charge.
45S& F in repalcement of MCCB 3 Pole, 415 V, fixed type, 25 to 100 Amps with breaking capacity 16 KA complete all as specified and directed by Engr-in-Charge.
46S& F in repalcement of MCCB 4 Pole, 415 V, fixed type, 160 Amps with breaking capacity 36 KA complete all as specified and directed by Engr-in-Charge.
47All As per item no 43 above but of size Adjustable type, 200 Amps with breaking capacity 36 KA complete all as specified and directed by Engr-in-Charge.
48All As per item no 43 above but of size Adjustable type, 250 Amps with breaking capacity 36 KA complete all as specified and directed by Engr-in-Charge.
49M&L Earthing complete with copper plate electrode 60×60cm ×3.15mm size & copper strip 20 x 3 mm brazed with copper plate buried in ground not less than 1.5 Mtrs deep with PCC chamber complete all as specified and as directed means of bolts, nuts, check nuts and washers of brass check nuts and washers of brass including necessary earth work, PCC chamber , CI cover with frame, funnel, mesh, Earth lead protection pipe, 7.5 Meter Earth Lead etc all as shown in electrical plate No 3 in SSR Part-I and connected to earth test point/LT Panel/Transformer including testing on completion all as directed by Engr in-Charge Note : Amount Includes all Earth work PCC ,earth, Pit, CI CoverFunnel ,wire mesh, Copper Lugs, GI Protection pipe etc complete all as specified and directed by Engr-in-Charge. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 58061098
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 32 Lakhs
LAST DATE 03-11-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Repair/Maintenance Of Lt Distribution Cables, Lt Panels, Lt Cable Joints & Switch Gears Connected Misc Works At repair renovation 3, Sub Stations Los,Santacruz ,765 Su & Hq Mao Under Afs Mumbai Under Ge Af Thane
Basic Detail
Tender No GE (AF) T-61 OF 2026-27 (8678)
Bidding Type Tender
Location
City Thane
State Maharashtra
Key Dates
Publish Date 15 Oct 2026
Submission Date 03 Nov 2026
Open Date 10 Nov 2026
Finance
Tender Value 32 Lakhs
Tender Fee 500
EMD 64000
Exemption Available
Document List
697eed38-803a-4a4c-a073-587bcc014778.html
BOQ_890421.xls
TD8678.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Oct 15, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Nov 03, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 6 days
Nov 10, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 13 days

Tender Documents

Download All (ZIP) ↓
html

697eed38-803a-4a4c-a073-587bcc014778.html

xls

BOQ_890421.xls

pdf

TD8678.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender