Tender For Special Repairs By Rewiring And Renewal Of Fittings Fans And Air Conditioners In The Wornout Portions In Rdo Office At Sivagangai In Sivagangai District
Tender Value
6.15 Lakhs
Estimated cost
Bid Submission
29 Oct 2026
12 days left
EMD
6200
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Sivaganga → Tamil Nadu
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Special Repairs By Rewiring And Renewal Of Fittings Fans And Air Conditioners In The Wornout Portions In Rdo Office At Sivagangai In Sivagangai District
BOQ
| Sl. No. | Item Description |
| 1 | Rewiring with 2x1.5 sq.mm.PVC insulated unsheathed FRLS SC copper conductor of 1100V grade insuitable PVC rigid pipe on wall and ceiling with PVC accessories with TW switch box with 5A FT switch in flush with wall covered with hylum sheet of 3mm thick with painting of suitable colour for open PVC light/fan point (for electronic regulator) (5pointspercoil) |
| 2 | Renewal by supply and fixing of 4Feet LED 20W Fitting with LED 20W tube (HigherEnd) complete with TW round blocks on wall or ceiling with PVC unsheathed FRLS Copper leads from terminals to the fitting. |
| 3 | Renewal by supply and fixing of 1200mm (48\\") sweep AC ceiling fan High speed complete with 300W stepped electronic regulator (Higher end) with 300 mm down rod on the existing fan clamp. |
| 4 | Renewal by supply and fixing of 3Nos. 5A(3pinand2pin)combined flush type wall socket with control switches concealed insuitable TW box covered with hylem sheet in flush with wall with earth connection (for computer plug socket) |
| 5 | Renewal by supply and Run of 2 of 2.5 sq.mm. PVC insulated SC unsheathed FRLS copper conductor of 1100 V grade in suitable PVC rigid pipe on wall and ceiling with continuous earth wire connection of 2.5 sq.mm copper wire with painting of suitable colour.(For set plug) |
| 6 | Supply and fixing of 25A Flushtype Wall Socket 25A DP MCB complete set for AC Plug inflush with wall with earth connection (For AC Plug) |
| 7 | Supply and fixing of 6 way Horizontal Triple pole and neutral MCB sheet steel enclosure distribution board with double door (metal) with 1 No 63A 4P MCB as incoming and 18 Nos 6A to 32A SP MCB as outgoing on suitable angle iron frame on wall with Earth connection only. Higher End ( Total Control DB) |
| 8 | Supply, erection and commissioning of 2.0TR (6000 K Cal / Hr) ABS Plastic Split type Airconditioner conforming to IS : 1391 (Part 2) 1992 with Amdt. No. 1 to 2 fitted with rotary compressor operating refrigerant R - 22 / Non- CFC suitable for wall mounting for operation on 230 Volt, 50 HZ Single Phase operating refrigerant R - 22 / Non- CFC suitable for wall mounting for operation on 230 Volt, 50 HZ Single Phase AC supply with Star rating of 5 as per BEE specification and capable of performing the functions of |
| 9 | 1) Cooling, 2) Dehumidifying, 3) Air circulating, 4) Filtering The installation works for the above split type |
| 10 | AC units includes the following : 1) Mounting / Fitting indoor and outdoor units at the respective locations. |
| 11 | 2) Laying refrigerant pipeline of required length not |
| 12 | exceeding 4 metres distance and connecting both units after drilling hole / holes in the wall, if required. Thickness of copper tubing shall not be less than 0.7mm. |
| 13 | 3) Insulating the suction pipe with expanded polyethylene foam 5mm tubing. |
| 14 | 4)Laying 15mmout the condensate water being formed within indoor unit. |
| 15 | 5) Leakage testing the entire system. 6) Charging refrigerant gas in the unit. |
| 16 | 7)Suitable electric wiring to be provided with 2.5 sqmm PVC insulated copper wire between indoor and outdoor units upto 6 mtrs length and upto switch within 3 mtrs of location of indoor unit. |
| 17 | Supply and installation of 5.0 KVA Electronic Automatic Voltage Stabilizer V Guard Make VGS 400 model with input voltage Range of 170 volt to 270 volt and output voltage range 200 volts to 240 volts with High and low voltage cut off and 3 minutes time delay relay with demonstration. |
| 18 | Supply and fixing of MS stand for fixing outdoor unit. |
| 19 | Supply and laying of 5/8\\" and 3/8\\" copper pipe (Extra beyond 3 metres supplied with AC unit) |
| 20 | Supply and run of 2 of 4 sq.mm.PVC insulated SC unsheathed FRLS copper conductor of 1100V grade insuitable PVC rigid pipe on wall and ceiling with continuous earth wire connection of 4 sq.mm copper wire with painting of suitable colour. |
| 21 | Renewal by supply and fixing of 300mm (12\\") sweep (light duty) AC exhaust fan complete without provision of hole in the wall. |
| 22 | Renewal by supply and fixing of louvers shutters arrangements for 300mm (12\\") sweep (light duty) AC exhaust fan. |
| 23 | Supply and fixing of 400mm sweep (16\\") wall mounting fan complete with special type clamping arrangements. |
| 24 | Supply and fixing of5A/15A3pin combined flush type wall socket with 15A flush types witch concealed insuitable TW box in flush with wall and covered with 3mm thick hylem sheet. |
| 25 | Supply and fixing of 24W LED 2x2 square type Recessed fitting with LED (Higher end) on false Ceiling with suitable hanging support from ceiling with PVC unsheathed copper leads from terminals to the fitting. |
| 26 | Supply and fixing of 3 kVA single phase in & single phase out online UPS of microcontroller based high frequency and double conversion online technology with inbuilt isolation transformer system, LCD/ LED Display with suitable SMF battery to provide minimum 1 hour backup along with powder coated MS Rack and interlink cables with following specifications: |
| 27 | 1. Output Voltage Range : 208V/220V/230V/240V AC2. Voltage THD (Linear Load) : ≤2%3. Voltage THD (Non-Linear Load) : ≤4%4. Current THD : < 10%5. Overload : >110%, 30s turn to Bypass mode; >150% instant turn to Bypass mode6. Short Circuit protection : 5 cycles turn off inverter, no transfer to Bypass, provide Alarm (AC mode) ; 5cycles turn off inverter, provide Alarm (Battery mode), Input fuse blown or breaker action7. Waveform : Pure sinewave |
| 28 | 8. Transfer time : (AC mode to Battery mode - Zero) (Inverter to bypass - <4ms)9. Efficiency : 85% to 92%10. Noise Level : less than 50dBA @ 1meter (with fan speed control)11. Warranty : Two years on Electronics & one year on battery.(UPS make: Microtek / Numeric make), (Battery make : Exide) The make and model should be approved by the departmental officers before execution. |
| 29 | supply and run 1 of 1.5 sq mm PVC insulated SC Unsheathed FRLS copper conductor of 11001V grade in excisting PVC rigid pipe. |
| 30 | Earthing as per the ISI specification with an earth electrode of 2.10metre Class'B' GI pipe of dia not less than 40mm with copper earth plate of size 125mmx50mmx6mm with necessary funneling arrangements with necessary masonry work and with 38mm RCC cover slab for the brick masonry. |
| 31 | Supply and Run of 1 of No.8 SWG copper wire in suitable PVC rigid pipe on wall / floor / ground for earth connection. |
| 32 | Supply and fixing of 8 way single pole and neutral MCB sheet steel enclosure distribution board with double door (metal) with 1 no. 32A DP MCB as incoming and 6 nos. 6A to 32A SP MCB as outgoing on wall with earth connection only. Lower End (For UPS) |
| 33 | Supply and fixing 32A,10KA double pole MCB in sheet steel enclosure in flush with wall and making good of the concealed portion with necessary earth connection (The MCB and metal enclosure should be of higher end) |
| 34 | GST @ 18 % Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Oct 15, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedOct 29, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 12 daysOct 29, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 12 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender