Housing Urban and Rular Development Government Departments Closing in 6 days TDR #58060157

Tender For repair maintenance Various E&M Services In Various Delhi Govt. Staff Qtrs. Under Ae (E) Emsd-Iii, Sunlight Colony, New Delhi. (Sh:- Electrical Upgradation And Repair Work At Various Pwd Staff Qtrs.)

Issued by Government Departments · Delhi, Delhi
Tender Value
27.32 Lakhs
Estimated cost
Bid Submission
22 Oct 2026
6 days left
EMD
54652
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Delhi → Delhi
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for repair maintenance Various E&M Services In Various Delhi Govt. Staff Qtrs. Under Ae (E) Emsd-Iii, Sunlight Colony, New Delhi. (Sh:- Electrical Upgradation And Repair Work At Various Pwd Staff Qtrs.)

BOQ

Name of Work:- RMO Various E&M Services in various Delhi Govt. Staff Qtrs. under AE (E) EMSD-III, Sunlight Colony, New Delhi. (SH:- Electrical upgradation and repair work at various PWD staff qtrs.)
Sl. No. Item Description
1Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mmFRLS/HFFR PVC insulated copper conductor single core cable in surface/ recessed steel conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable etc. as required.
2a) Group A
3a) Group B
4Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable and 1.5 sq.mm. FRLS/HFFR PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel conduit including dismantling as required.
5a) Group A
6a) Group B
7Supplying and fixing of following sizes of steel conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required.
820 mm
925 mm
10Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required.
11a) 3 x 1.5 sq.mm
12b) 6 x 1.5 sq.mm
13c) 3 x 4 sq.mm
14d) 6 x 4 sq.mm
15e) 3 x 6 sq.mm
16Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in existing surface/ recessed medium class PVC/MS conduit as required
17a) 2 X 10 sq. mm + 1 X 6 sq. mm earth wire
18Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc as required.
19a) 1 or 2 Module (75mmX75mm)
20b) 3 Module (100mmX75mm)
21c) 6 Module (200mmX75mm)
22d) 8 Module (125mmX125mm)
23e) 12 Module (200mmX150mm)
24Supplying and fixing following modular switch / socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.
25a) 5/6 amp switch
26b) 3 pin 5/6 amp socket outlet
27c) 15/16 amp switch
28d) 6 pin 15/16 amp socket outlet
29E) Bell Push
30Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required.
31a) 1 or 2 Module
32b) 3 Module
33c) 6 Module
34d) 8 Module
35e) 12 Module
36Supplying and fixing of two module stepped type electronic fan regulator on the existing modular plate switch box i/c connections but excluding modular plate etc as reqd.
37Supplying and fixing call bell/ buzzer suitable for single phase, 230 V, complete as required.
38Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required.
39Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.
40Supplying and fixing following way, single pole and neutral, sheet, steel, MCB distributions board, 240 volts, on surface/recess, complete with tinned copper busbar, neutral busbar, earth bar, din bar, detachable gland plate, interconnections, phosphatized and powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
41a) 16way Double door
42Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
43a) Single pole
44Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.
45a) 63 amp
46Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual currentcircuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.
47a) 63 A
48Supplying, installation, Testing & Commissioning of LED surface mounted Batten light of following body material and construction as per IS : 10322 with driver (Replaceable) as per the requirement with Driver efficiency >85% ,Operating voltage AC 140-270 Volt, freq 50/60 hz, Operating temp range -5 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80, Flicker free, (flicker should be below 5 %), life time (LED,Driver & electrical circuitary), of minimum 50000 Burning Hours with , 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard and trade mark certificate (T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). Powder Coated CRCA Sheet Body (Thickness >0.50 mm)
49a) 18- 22 watt
50b) 36 watt
51Supplying, installation, Testing & Commissioning of LEDRecessed / surface Down lighter (Round/ square/ Rectangular) SMD type of following body material with PMMA and prismatic diffuser and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range -5 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80 , UGR (Unified Glare Rating) < 19, Flicker free (flicker should be below 5%), life time (LED,Driver & electrical circuitary), of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends , CCT 3000°K / 4000°K / 5700°K / 6500°K (As per ANSI Bin), SDCM (Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be confirming to relevant BIS standards and trade mark certificate (T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing Complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 and <120 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted..
52Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C) Powder coated die cast /Extruded aluminium Body including trim
53a) 18 Watt
54Supplying. Installation, testing and commissioning of 300 mm sweep metallic heavy duty 900 rpm exhaust fan suitable for operation on 230V, 50 Hz single phase AC supply complete with louvers / shutters in the existing opening including making the hole to suit the size of the above fan making good the damage and connections etc. as reqd.
55Supplying & Intallation of fresh air fan 250 mm sweep with shutter and louver in the existing opeining , including making the hole to suit the size of the above fan, making good the damage, connection, testing, commissioning etc. as required.
56Supply, Installation, Testing and Commissioning of ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. metal( Aluminium alloy) blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, steel/Al body Power Factor not less than 0.9, Service Value (CM/M/W) minimum as below, 350 RPM (tolerance as per IS : 374-2019), THD (Total Harmonic Distortion) less than 10%, suitable for operation with regulator for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 0C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC supply, Ceiling Fan compliant to IS 374:2019 fan i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required.
57a) 1200mm, service value ≥ 6.0 CM/Min/Watt, air delivery 210 CM/Min (Minimum)
58Supplying, installation & testing & commissioning of 10W Edge Lite Linear LED Mirror Light (6000K) luminarie having i integrated LED Driver with high transitivity opal diffuser for direct lighting i/c wiring and making connections with 1.5sq.mm. PVC insulated FRLS, copper conductor, single core cable complete etc. as required, suitable for conduit/surface/suspended mounting etc. complete with all accessories/attachments etc as reqd.
59SITC of 10watt integrated LED bulk head IP 65 protectin luminiare comprises of pressure die cast housing acrylic disffuser and frame directly on wall i/c connection etc as reqd.
60Supplying, installation & testing & commissioning of decorative wall mounting Light with opal glass diffuser suitable for upto 10 W LED filament candle lamp B-22 base direct on wall including connection with 1.5sqmm FRLS copper conductor cable etc. as required.
61Supply, Installation, Testing and Commissioning of 25 litre Water Storage Heater/Geyser BEE 5 star rated ISI Marked, Rated power input 2000 W, Energy saving PUF insulation, powerful heating element rust proof suitable with 230V 50 Hz AC supply, temperature control feature minimum 2 Years warranty, power cord with 3 pin plug, 1 mannual, Wall Mounting accessory & 2 flexi pipe and with all other accessories i/c connection etc. as required
62Supply, installation, testing and commissioning of panel board with dust & vermin proof IP-42 protection compartmentalized indoor type cubical panel board made out of not less than 1.6 mm thick CRCA sheet, the sheet steel member shall be stiffened by angle iron framed. The depth of cubical panel shall not be less than 300 mm and suitable sizes earth strip shall be provided around the cubical panel. The cubical panel shall be of suitable size to incorporate following switchgear i/c connections, powder coating of approved colour and shades complete etc. as reqd. Panel should be fixed on CC foundation/ angle iron frame work. 100A, 25KA, 4P incomer MCCB-1 No.63A DP 10KA MCB- 6 NosR,Y,B Phase Indicating Lamp-03Nos150A TPN, Aluminium Bus BarExtended Rotating Handle & Spreader -01NoSingle Phase Energy Meter housing of space Provision for= 06Nos.
63Credit for dismantle materials
64Assorted : Ceiling Fan
65Assorted : Exhaust Fans
66Assorted : Switch/socket/regulator/ (Piano/Modular)
67Assorted : SP /DP MCB upto 63 A
68Assorted : SP MCB DB
69Assorted : Al. Wire with insulation
70Assorted : GI Box with modular plate/phenolic sheet
71Assorted : LED batten/Downlighter/fl. Fitting
72Assorted : Fresh Air Fan Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 58060157
AUTHORITY Government Departments
TENDER VALUE 27.32 Lakhs
LAST DATE 22-10-2026
Authority
Authority Name Public Works Department
Work Description Tender for repair maintenance Various E&M Services In Various Delhi Govt. Staff Qtrs. Under Ae (E) Emsd-Iii, Sunlight Colony, New Delhi. (Sh:- Electrical Upgradation And Repair Work At Various Pwd Staff Qtrs.)
Basic Detail
Tender No 133/EE(E)/EMD South East/PWD/2026-27
Bidding Type Tender
Location
City Delhi
State Delhi
Key Dates
Publish Date 15 Oct 2026
Submission Date 22 Oct 2026
Open Date 22 Oct 2026
Finance
Tender Value 27.32 Lakhs
Tender Fee Ref. Documents
EMD 54652
Exemption Not Available
Document List
47045486-eb43-4523-9716-e5f8be4385a1.html
BOQ_400442.xls
tender.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Oct 15, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Oct 22, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 6 days
Oct 22, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 6 days

Tender Documents

Download All (ZIP) ↓
html

47045486-eb43-4523-9716-e5f8be4385a1.html

xls

BOQ_400442.xls

pdf

tender.pdf

pdf

Tendernotice_1.pdf

Disclaimer