Tender For Repair / Maintenance Of Lt Panels, Mccbs And Connected Works At Lichubari And Mariani And Repair / Maintenance Of High Mast Light, Street Light, Led Flood Light Nd Connected Works At Different Location Under Ge Jorhat.
Tender Overview
Project Description
Tender for Repair / Maintenance Of Lt Panels, Mccbs And Connected Works At Lichubari And Mariani And Repair / Maintenance Of High Mast Light, Street Light, Led Flood Light Nd Connected Works At Different Location Under Ge Jorhat.
BOQ
| Sl. No. | Item Description |
| 1 | NOTE:-(i) The bidders/contractors are advised to read tender document & all corrigendum / amendments and General conditions of contracts before entrying/quoting the rates.(ii) It is highlighted that the certain condition of General Condition of Contracts (IAFW-2249) has been modified as per direction of MoD i.e. inclusssion of Performance Security, deletion of Risk & Cost Provisions and increase in defect liability period all as per tender documents. The tenderers should keep in mind while quoting their offer. (iii) (Applicable for all items/parts):- The bidders/contractors are advised to refer Notes on BOQ/SCH'A' before entry/quoting the rates. |
| 2 | Supply and fixing as in replacement PVC insulated multicore FR PVC sheathed 1.5 sqmm 3 core multi strand copper conductor for connection of security light from Junction Box to security light complete all as specified and as directed. |
| 3 | Supply and laying PVC insulated (Heavy duty) armoured 1100 volts grade aluminium conductor cable of size 4 Sqmm 2 core including connection cable glands, aluminium lugs etc. and replaement of old unserviceable cable complete all as specified and as directed. |
| 4 | Supply and laying under ground XLPE insulated PVC sheathed (Heavy duty) armoured 1100 volts grade aluminium conductor cable of size 10 Sqmm 2 core laid in trenches as per IS 7098 (Part I) including connection cable glands, aluminium lugs etc. and replaement of old unserviceable cable complete all as specified and as directed. |
| 5 | Supply and laying under ground XLPE insulated PVC sheathed (Heavy duty) armoured 1100 volts grade aluminium conductor cable of size 16 Sqmm 4 core laid in trenches as per IS 7098 (Part I) including connection cable glands, aluminium lugs etc. and replaement of old unserviceable cable complete all as specified and as directed. |
| 6 | Supply and laying under ground XLPE insulated PVC sheathed (Heavy duty) armoured 1100 volts grade aluminium conductor cable of size 25 Sqmm 4 core laid in trenches as per IS 7098 (Part I) including connection cable glands, aluminium lugs etc.and replaement of old unserviceable cable complete all as specified and as directed. |
| 7 | Supply and laying under ground XLPE insulated PVC sheathed (Heavy duty) armoured 1100 volts grade aluminium conductor cable of size 35 Sqmm 3.5 core laid in trenches as per IS 7098 (Part I) including connection cable glands, aluminium lugs etc. and replaement of old unserviceable cable complete all as specified and as directed. |
| 8 | Supply and laying under ground XLPE insulated PVC sheathed (Heavy duty) armoured 1100 volts grade aluminium conductor cable of size 50 Sqmm 3.5 core laid in trenches as per IS 7098 (Part I) including connection cable glands, aluminium lugs etc. and replaement of old unserviceable cable complete all as specified and as directed. |
| 9 | Supply and laying under ground XLPE insulated PVC sheathed (Heavy duty) armoured 1100 volts grade aluminium conductor cable of size 70 Sqmm 3.5 core laid in trenches as per IS 7098 (Part I) including connection cable glands, aluminium lugs etc. and replaement of old unserviceable cable complete all as specified and as directed. |
| 10 | Supply and laying under ground XLPE insulated PVC sheathed (Heavy duty) armoured 1100 volts grade aluminium conductor cable of size 120 Sqmm 3.5 core laid in trenches as per IS 7098 (Part I) including connection cable glands, aluminium lugs etc. and replaement of old unserviceable cable complete all as specified and as directed. |
| 11 | Supply and fixing as in replacement for LT 1.1 KV (Earthed) grade heat shrinkable end termination jointing kit straight through type complete with jointing material and accessories suitable for 4 core XLPE armoured aluminium conductor cable of size 10 to 16 sqmm complete all as specified and as directed. |
| 12 | Supply and fixing as in replacement for LT 1.1 KV (Earthed) grade heat shrinkable end termination jointing kit straight through type complete with jointing material and accessories suitable for 3.5 core XLPE armoured aluminium conductor cable of size 25 to 50 sqmm complete all as specified and as directed. |
| 13 | Supply and fixing as in replacement for LT 1.1 KV (Earthed) grade heat shrinkable end termination jointing kit straight through type complete with jointing material and accessories suitable for 3.5 core XLPE armoured aluminium conductor cable of size 70 to 150 sqmm complete all as specified and as directed. |
| 14 | Material and labour for HDPE pipe of pressure rating 10 kgf/cm² and dia 75 mm for passing of cable through PCC foundation from trench to distribution board with necessary clamp nuts and bolts complete all as specified and as directed. |
| 15 | Material and labour for HDPE pipe of pressure rating 10 kgf/cm² and dia 32 mm for passing of cable through PCC foundation from trench to distribution board with necessary clamp nuts and bolts complete all as specified and as directed. |
| 16 | Material and labour for HDPE pipe of pressure rating 10 kgf/cm² and dia 25 mm for passing of cable through PCC foundation from trench to distribution board with necessary clamp nuts and bolts complete all as specified and as directed. |
| 17 | Supply and laying GI tubing 40mm bore light grade with fittings laid in trenches or for road crossing for protection of LT underground cables including taking up old unserviceable pipe complete all as specified and as directed. |
| 18 | Supply and laying GI tubing 80mm bore light grade with fittings laid in trenches or for road crossing for protection of LT underground cables including taking up old unserviceable pipe complete all as specified and as directed. |
| 19 | Labour only for boring of hole under roads with mechanical arrangement upto 80 mm dia without disturbing the top surface of the road for passing the cable across the road complete all as specified and as directed. |
| 20 | Supply and fixing as in replacement MCCB triple pole and neutral (Four pole) 400 Amp, 415 volts, 50 Hz, having thermal setting range 70% to 100% and fixed magnetic setting and breaking capacity 36 KA including making incoming and outgoing connections complete all as specified and as directed. |
| 21 | Supply and fixing as in replacement MCCB triple pole and neutral (Four pole) 350 Amp, 415 volts, 50 Hz, having thermal setting range 70% to 100% and fixed magnetic setting and breaking capacity 36 KA including making incoming and outgoing connections complete all as specified and as directed. |
| 22 | Supply and fixing as in replacement MCCB triple pole and neutral (Four pole) 250 Amp, 415 volts, 50 Hz, having thermal setting range 70% to 100% and fixed magnetic setting and breaking capacity 25 KA including making incoming and outgoing connections complete all as specified and as directed. |
| 23 | Supply and fixing as in replacement MCCB triple pole and neutral (Four pole) 200 Amp, 415 volts, 50 Hz, having thermal setting range 70% to 100% and fixed magnetic setting and breaking capacity 25 KA including making incoming and outgoing connections complete all as specified and as directed. |
| 24 | Supply and fixing as in replacement MCCB triple pole and neutral (Four pole) 160 Amp, 415 volts, 50 Hz, having thermal setting range 70% to 100% and fixed magnetic setting and breaking capacity 18 KA including making incoming and outgoing connections complete all as specified and as directed. |
| 25 | Supply and fixing as in replacement MCCB triple pole and neutral (Four pole) 125 Amp, 415 volts, 50 Hz, having thermal setting range 70% to 100% and fixed magnetic setting and breaking capacity 16 KA including making incoming and outgoing connections complete all as specified and as directed. |
| 26 | Supply and fixing as in replacement MCCB triple pole and neutral (Four pole) 100 Amp, 415 volts, 50 Hz, having thermal setting range 70% to 100% and fixed magnetic setting and breaking capacity 16 KA including making incoming and outgoing connections complete all as specified and as directed. |
| 27 | Supply and fixing as in replacement MCCB triple pole and neutral (Four pole) 63 Amp, 415 volts, 50 Hz, having thermal setting range 70% to 100% and fixed magnetic setting and breaking capacity 16 KA including making incoming and outgoing connections complete all as specified and as directed. |
| 28 | Supply and fixing as in replacement steel tubular swaged poles, type 410 SP-31 (Overall length 9.00 meter) conforming to IS-2713 (Part 1 to 3) 1980 complete with cast iron base plate, finial taper plug, bolts, nuts and washers, screws. Pole shall be painted with two coat of black bituminous throughout internally and externally upto planting depth and the remaining external portion shall be painted with two coats of aluminum paints over a coat of red oxide primer, painting black & white alternate strips of 30cm each externally from ground level upto 1.2m with synthetic enamel paint, numbering of poles complete all as specified and as directed.Note: Excavation and earth work and PCC shall be measured and paid separately under respective items. |
| 29 | Supply and fixing as in replacement 10W cool day light white LED bollard light made of pressure die-cast aluminium housing with inverted tripod type diffuser with 360° soft light distribution, IP65 protection, high power LEDs and system efficacy should be greater than 100 lumen per watt complete all as specified and as directed. |
| 30 | Supply and fixing as in replacement 40 Watt LED post top (white colour), 230 volt, 360 degree made in cast aluminium spigot housing with decorative opal acrylic diffuser and IP65 protection including fixing with LED driver and lamp complete all as specified and as directed. |
| 31 | Supply and fixing as in replacement asymmetrical LED flood light luminaires, 50 watt, 230 Volt, 50 Hz, LED 5000K, IP66 Metal Halide, grey powder coated die-cast aluminium lamp housing, bult-in control gear, faceted anodised aluminium reflector heat resistant toughened clear glass cover complete including connecting and testing all as specified and as directed. |
| 32 | Supply and fixing as in replacement asymmetrical LED flood light luminaires, 200 watt, 230 Volt, 50 Hz, LED 5000K, IP66 Metal Halide, grey powder coated die-cast aluminium lamp housing, bult-in control gear, faceted anodised aluminium reflector heat resistant toughened clear glass cover complete including connecting and testing all as specified and as directed. |
| 33 | Supply and fixing as in replacement Compact street lighting luminaires with deep drawn housing for single 30 Watt LED, 5700K with toughened glass protection, pressure die cast aluminium housing IP66,with epoxy white powder coated and fixing bracket made of 32mm bore galvanised iron light grade pipe made to shape having overall length 1.2 mtr,fixed over the vertical wall through two numbers mild steel clamp of 25mm width, 3mm thick MS flat strip and four Nos nuts, bolts & washers of 12mm dia, 150mm long grouted into wall complete all as specified and as directed. |
| 34 | Supply and fixing as in replacement Compact street lighting luminaires with deep drawn housing for single 45 Watt LED, 5700K with toughened glass protection, pressure die cast aluminium housing IP66,with epoxy white powder coated and fixing bracket made of 32mm bore galvanised iron light grade pipe made to shape having overall length 1.2 mtr,fixed over the vertical wall through two numbers mild steel clamp of 25mm width, 3mm thick MS flat strip and four Nos nuts, bolts & washers of 12mm dia, 150mm long grouted into wall complete all as specified and as directed. |
| 35 | Supply and fixing as in replacement Compact street lighting luminaires with deep drawn housing for single 60 Watt LED, 5700K with toughened glass protection, pressure die cast aluminium housing IP66,with epoxy white powder coated and fixing bracket made of 32mm bore galvanised iron light grade pipe made to shape having overall length 1.2 mtr,fixed over the vertical wall through two numbers mild steel clamp of 25mm width, 3mm thick MS flat strip and four Nos nuts, bolts & washers of 12mm dia, 150mm long grouted into wall complete all as specified and as directed. |
| 36 | Supply and fixing as in replacement Compact street lighting luminaires with deep drawn housing for single 70 Watt LED, 5700K with toughened glass protection, pressure die cast aluminium housing IP66,with epoxy white powder coated and fixing bracket made of 32mm bore galvanised iron light grade pipe made to shape having overall length 1.2 mtr,fixed over the vertical wall through two numbers mild steel clamp of 25mm width, 3mm thick MS flat strip and four Nos nuts, bolts & washers of 12mm dia, 150mm long grouted into wall complete all as specified and as directed. |
| 37 | Supply and fixing as in replacement Compact street lighting luminaires with deep drawn housing for single 90 Watt LED, 5700K with toughened glass protection, pressure die cast aluminium housing IP66,with epoxy white powder coated and fixing bracket made of 32mm bore galvanised iron light grade pipe made to shape having overall length 1.2 mtr,fixed over the vertical wall through two numbers mild steel clamp of 25mm width, 3mm thick MS flat strip and four Nos nuts, bolts & washers of 12mm dia, 150mm long grouted into wall complete all as specified and as directed. |
| 38 | Supply and fixing as in replacement street light bracket fabricated from 40 mm bore GI light-grade steel tube, bent to the required shape and having overall length of 1.5 m, complete with suitable MS mounting clamps fabricated from 40 × 5 mm flat iron of required length, fixed with two pairs of suitable size bolts, nuts and washers, including necessary cutting, bending, drilling, welding, painting/finishing and fixing accessories, complete all as specified and as directed |
| 39 | Materials and labour as in replacement for earthing complete with galvanised iron earth plate electrode 600 mm x 600 mm x 6 mm thick, burried directly and preferably vertically in ground, earth pit not less than 2.25 Mtr deep below ground level with top edge of the plate not less than 1.5 m below ground level connetced with galvanised strip 32x6mm by means of nuts, bolts, check nuts and washers made of galvanised iron or steel earthing lead to be protected by galvanised iron pipe of 40mm bore (light grade) and other end connected to earthing test point or lightening arrestor or main controlling switch as directed including providing funnel with 20mm bore galvanised iron pipe (medium grade), wire mesh, charcoal or coke and common salt in alternate layer of 15cm (compacted thickness) all round the earth electrode, concrete earth pit in PCC (1:3:6) type C-1 (with 20mm graded aggregate), 50mm thick precast RCC (1:2:4) cover slab (re-inforced with 8mm dia TMT bar @ 15 cm C/C bothways and suitable handle made of 10mm dia) including necessary earth work in excavation, returning filling and removal of surplus earth upto a distance not exceeding 50 m etc all as shown on electrical plate No. 3 of MES Schedule Part-I(2009) complete including testing on completion all as specified and as directed. |
| 40 | Supply and fixing as in replacement of LED driver suitable for 45W LED street light fitting, constant-current type, suitable for the existing LED luminaire, with input voltage 230V AC ±10%, power factor ≥0.95, THD ≤10%, efficiency ≥90%, with necessary surge protection and suitable IP-rated housing/enclosure, including removal of defective driver, reconnection of input/output wiring with suitable terminals/connectors, complete all as specified and as directed. |
| 41 | Supply and fixing as in replacement of LED driver suitable for 60W LED street light fitting, constant-current type, suitable for the existing LED luminaire, with input voltage 230V AC ±10%, power factor ≥0.95, THD ≤10%, efficiency ≥90%, with necessary surge protection and suitable IP-rated housing/enclosure, including removal of defective driver, reconnection of input/output wiring with suitable terminals/connectors, complete all as specified and as directed. |
| 42 | Supply and fixing as in replacement of LED driver suitable for 150/200W LED flood fitting, constant-current type, suitable for the existing LED luminaire, with input voltage 230V AC ±10%, power factor ≥0.95, THD ≤10%, efficiency ≥90%, with necessary surge protection and suitable IP-rated housing/enclosure, including removal of defective driver, reconnection of input/output wiring with suitable terminals/connectors, complete all as specified and as directed |
| 43 | Supply and fixing as in replacement of Surge Protection Device (SPD) suitable for LED flood light and street light fittings of different wattages, rated for minimum 10 kV surge protection, suitable for 230 V AC system, complete with necessary mounting arrangement, terminal connections, wiring/accessories and enclosure wherever required, including removal of existing defective SPD, reconnection, complete all as specified and as directed. |
| 44 | Supply and fixing as in replacement of analogue daily programmable time switch/timer, 24-hour type, 240 V AC, suitable for automatic control of street lighting, DIN-rail/base mounting type, complete with necessary mounting arrangement, terminals and accessories, reconnection of wiring, setting/programming, testing complete all as specified and directed. |
| 45 | Supply and fixing as in replacement MCB FP, 240 Volts, of 63 amps current rating, 10 KA breaking capacity ‘C' series complete all as specified and as directed. |
| 46 | Supply and fixing in replacement of 3 pole power contactors, type MCX21, suitable for 65 Amps AC rating complete all as specified and as directed. |
| 47 | Taking down and refixing the existing high-mast raising/lowering gear mechanism for 15 m high mast light, comprising gear box, stainless steel wire rope, jubilee clamps, lifting/lowering lever, rope guide/pulleys and all associated fixtures/accessories, including lowering of the existing raising/lowering carriage, careful dismantling, inspection, cleaning, servicing/adjustment and replacement of minor fixing accessories as required, and thereafter refixing, aligning, tensioning and testing the complete mechanism for proper raising and lowering of the carriage carrying 6/9 Nos. LED flood light fittings, including all labour, tools, tackles, consumables and incidental works, complete all as specified and as directed. Please Enable Macros to View BoQ information |
| 48 | Taking down and refixing the existing high-mast raising/lowering gear mechanism for 15 m high mast light, comprising gear box, stainless steel wire rope, jubilee clamps, lifting/lowering lever, rope guide/pulleys and all associated fixtures/accessories, including lowering of the existing raising/lowering carriage, careful dismantling, inspection, cleaning, servicing/adjustment and replacement of minor fixing accessories as required, and thereafter refixing, aligning, tensioning and testing the complete mechanism for proper raising and lowering of the carriage carrying 6/9 Nos. LED flood light fittings, including all labour, tools, tackles, consumables and incidental works, complete all as specified and as directed. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 8 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 9 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender