Bids Are invited for Operation And Maintenance Of Electrical Systems/Electrical Installations - Complete System - Providing Operation And Maintenance Services For Internal And External E&M Installations Of Terminal Building, I/C Operation & Day To Da
Tender Overview
Project Description
Bids Are invited for Operation And Maintenance Of Electrical Systems/Electrical Installations - Complete System - Providing Operation And Maintenance Services For Internal And External E&M Installations Of Terminal Building, I/C Operation & Day To Day Check Of Lift Installed In Sha, Ups Etc. By Deploying Adequate Manpower As Per The Conditions Of Contract Involving Operation, Repairs & Maintenance, Rectification Of Faults / Breakdowns Ensuring Serviceability / Satisfactory Working Condition Of The Systems, Preventive Maintenance On Daily/ Weekly/ Monthly/ Quarterly/ Half Yearly/Yearly Basis, Maintenance Of Records/Documentation Etc. As Per Scope Of Work Given In Special Conditions And Technical Specifications Of Contract On All Day Including Sundays & Holidays. , Providing Operation And Maintenance Services Of E&M Installation In Operational Area Viz. Glf Systems, Navigational Aids Electrical Installations, Apron Flood Light, Other Electrical Installations , Internal & External E.I. Of Atc Tower Technical Block Cum Of Fire Station & Operation Of Lift, Ccr, Alcms & Ups (2 X 120 Kva) Etc. By Deploying Adequate Manpower As Per The Conditions Of Contract Involving Operation, Repairs & Maintenance, Rectification Of Faults/ Breakdowns Ensuring Serviceability/ Satisfactory Working Condition Of The Systems, Preventive Maintenance On Daily/ Weekly/ Monthly/ Quarterly/ Yearly Basis, Maintenance Of Records/ Documentation Etc. As Per Scope Of Work Given In Special Conditions And Technical Specification Of Contract On All Day Including Sundays & Holidays. , Supply Of 6 Sqmm, 5 Kv Grade Plug And Receptacle Of Type I, Class B Connector And Suitable Field Attachment With 5 Kv Grade Xlpe Insulated, Pe Sheathed, Single Core Copper Conductor Screened Cable As Required. , Supply Of 16 Sqmm, 5 Kv Grade Plug And Receptacle Of Type I, Class B Connector And Suitable Field Attachment With 5 Kv Grade Xlpe Insulated, Pe Sheathed, Single Core Copper Conductor Screened Cable As Required. , Supply Of Mandatory & Information Signages Fascia Boards Confirming To The Requirement Laid Down In Icao Annex-14 Volume-I & Aerodrome Design Manual Part Iv & V Made Out Of 4Mm Thick Poly Carbonate Sheet With Letters & Symbols Screen Printed On Inside Of Sign Face Made Of Self Adhesive 3M Film Applied On The Inside Face With Required Colouring. All Legends, Width & Height Of Each Letter Shall Be In Accordance To The Concerned Icao Annex-14 & Aerodrome Design Manual Part Iv & V. Details / Type Of Signages Fascia Shall Be As Per Site Requirement & Suitable For Replacement Of The Fascia In The Existing Sign Boards & Shall Be Got Approved From Eic Before Manufacturing Etc As Required. , Supply Of Electronic Led Convertor Suitable For Operation On 2.8- 6.6A Ac Constant Current As Incoming Supply Of The Isolating Transformers Of The Agl Series Ckt. & Suitable For Existing Airfield Led Signages. , Supply Of Following Rating Completely Enclosed Rubber Covered Isolating Transformer For Use In Series Airport Lighting Circuits Having Nominal Voltage Rating Of 5Kv And All Rated For Operation On 50 Hz. The Transformer Shall Be Water Tight And Shall Be Designed For Direct Burial In The Earth Or Installation In A Base Confirming To The Specifications, Complete As Required. , Supply Of Papi L Holder Suitable For 200 W, 6.6/6.6 A Ama Make, Mk- Iii Papi Light Fittings. , Supply Of Elevated Type Led Taxiway Edge Light Fitting (Mirl Fitting) For Use As Taxiway / Apron Edge /Turning Pad Lights Suitable For Operation At 2.8 S To 6.6 S Series Circuit Supply Current Complete With Suitable Leds, Omni-Directional Blue Lens (Glass), Lens Cl Ing Mechanism, Breakable Coupling, Rings /Gaskets, Base Plate With 06 Nos. M-10 Stainless Steel Bolts And Including An Integrated Encapsulated Suitable Electronic Converter With Standard Secondary Lead Etc. Complete Fitting Confirming To Latest Icao Standards /Requirement As Required. , Supply Of 105 Watt. Halogen L , 6.6 Halogen L Having Minimum Rated Life Of 1000 Hours Burning At Full Brilliancy. (For Inset Type Light Suitable For Ocem Make Slre - Runway Edge Light Fitting). Make: Narva, Model No. 6108, Make: Osram Model No: 64339 Or Equivalent. , Supply Of 200W, 6.6 A Halogen L - Lead Type Osram 64382 Hlx-C Or Equivalents Make Suitable For Ocem Make, Model: Fau-200 Approach Light Fitting. , Supply Of 150W, 6.6 A Ewr Halogen L Suitable For Elevated Type Runway Edge Light Fittings Of Astronics Dme Make (Model L-862) Of Halogen L Type 64354 Ewr, 150W, 6.6A Gy9.5 Of Osram Make Or Equivalent. , Supply Of 250 Rk 160 Ruttonsha Thyristor / Scr Suitable For Nasu Make, 30 Kw Constant Current Regulator (Ccr). , Supply Of 150 Rk 160 Ruttonsha Thyristor / Scr Suitable For Nasu Make, 20 Kw Constant Current Regulator (Ccr). , Supply Of 85 Rk 160 Ruttonsha Thyristor / Scr Suitable For Nasu Make, 7.5 Kw Constant Current Regulator (Ccr). , Supply Of 65 Rk 160 Ruttonsha Thyristor / Scr Suitable For Nasu Make, 4 Kw Constant Current Regulator (Ccr). , Calibration Of Papi Clinometer From Govt. Approved /Nabl Certified Lab. The Items Should Be Picked Up From The Airport Site And Bring Back In Good Position After Calibration. , Calibration Of Lux Meter From Govt. Approved /Nabl Certified Lab. The Items Should Be Picked Up From The Airport Site And Bring Back In Good Position After Calibration. , Carrying Out /Making In-Field Measurement Of Intensity, Beam Spread And Orientation (4Cs I.E.- Configuration, Colour, Candelas And Coverage) Chromaticity, Luminous Factor, One Time Field Alignment Setting For Inset/ Elevated Type Approach, Inset/Elevated Type Runway Edge, Elevated Runway End, Inset/Elevated Type Threshold, Papi Airfields Ground Lights, Replacement Of Burnt Out L , Lens, Filters, Any Corrective Action Etc. As Required (Spares To Be Provided By Aal) By Using Vehicle Mounted Mobile Testing Equipment System And Testing Of Individual Fitting.By Frame Reader, Submission Of Test Reports Etc As Per Requirement Of Icao/Civil Aviation Requirement (Car) Section-4 Aerodrome Standard & Licensing Series B Part-I, Technical Specification Etc. Complete As Required As Per The Detail Inventory Of Airfield Ground Lighting(Agl) Fixtures At The Airport.As Per Below Details: -A) Runway Edge Light - 179 Nos. B) Approach Light - 136 Nos.C) Sapl Lights - 17 Nos.D) Papi Lights - 02 Units.E) Threshold & End Lights - 48 Nos.F) Turnpad Lights - 60 Nos. , Supply Of 4 Head Led Airport Rotating Beacon Set Of Type L-802A Complying To Icao Annex-14 Para 5.3.3 & Faa : Ac 150 / 5345-12 Suitable For Operation On 220/240V, 50 Hz, Single Phase Ac Supply Having 04 Head, On/Off Control Panel & Compatible For On/Off Of Beacon From Remote Control Desk Of Atc Tower, Minimum Flash 20 - 30 Per Minute I/C All The Accessories Complete As Required. , Decorative Lighting Of Terminal Building And Garden Area With 100 Pcs Par Lights And 500 Pcs Fairy/ Rise Lights With All Accessories, Men And Materials, Wiring And Connections Etc. Complete As Required [Occasion Up To 3 Days = 1 Job].The Quantity And Colour Of Leds Will Be Decided By Engineer- In - Charge On Every Occasion. , Supply Of Wind Sock Cloth Of Color Red & White In The Form Of A Truncated Cone Made Of Fabric And Should Have A Length Of Not Less Than 3.6M And Diameter At Larger End Of Not Less Than 0.9M Confirming To Icao Annex 14 And Aerodrome Design Manual Part-6/Faa.
BOQ
| Sl. No. | Item Title | Item Description |
| 1 | Providing operation and maintenance services for Internal and External E&M Installations of Terminal Building, i/c Operation & day to day check of Lift installed in SHA, UPS etc. by deploying adequate manpower as per the conditions of contract involving operation, repairs & maintenance, rectification of faults / breakdowns ensuring serviceability / satisfactory working condition of the systems, preventive maintenance on daily/ weekly/ monthly/ quarterly/ half yearly/yearly basis, maintenance of records/documentation etc. as per scope of work given in special conditions and technical specifications of contract on all day including Sundays & Holidays. | Providing operation and maintenance services for Internal and External E&M Installations of Terminal Building, i/c Operation & day to day check of Lift installed in SHA, UPS etc. by deploying adequate manpower as per the conditions of contract involving operation, repairs & maintenance, rectification of faults / breakdowns ensuring serviceability / satisfactory working condition of the systems, preventive maintenance on daily/ weekly/ monthly/ quarterly/ half yearly/yearly basis, maintenance of records/documentation etc. as per scope of work given in special conditions and technical specifications of contract on all day including Sundays & Holidays. |
| 2 | Providing Operation and Maintenance Services of E&M Installation in Operational area viz. GLF Systems, Navigational Aids Electrical installations, Apron Flood Light, other Electrical installations , Internal & External E.I. of ATC tower Technical Block cum of fire station & operation of lift, CCR, ALCMS & UPS (2 x 120 KVA) etc. by deploying adequate manpower as per the conditions of contract involving operation, repairs & maintenance, rectification of faults/ breakdowns ensuring serviceability/ satisfactory working condition of the systems, preventive maintenance on daily/ weekly/ monthly/ quarterly/ yearly basis, maintenance of records/ documentation etc. as per scope of work given in special conditions and technical specification of contract on all day including Sundays & Holidays. | Providing Operation and Maintenance Services of E&M Installation in Operational area viz. GLF Systems, Navigational Aids Electrical installations, Apron Flood Light, other Electrical installations , Internal & External E.I. of ATC tower Technical Block cum of fire station & operation of lift, CCR, ALCMS & UPS (2 x 120 KVA) etc. by deploying adequate manpower as per the conditions of contract involving operation, repairs & maintenance, rectification of faults/ breakdowns ensuring serviceability/ satisfactory working condition of the systems, preventive maintenance on daily/ weekly/ monthly/ quarterly/ yearly basis, maintenance of records/ documentation etc. as per scope of work given in special conditions and technical specification of contract on all day including Sundays & Holidays. |
| 3 | Supply of 6 sqmm, 5 KV grade plug and receptacle of type I, class 'B' connector and suitable field attachment with 5 KV grade XLPE insulated, PE sheathed, single core copper conductor screened cable as required. | Supply of 6 sqmm, 5 KV grade plug and receptacle of type I, class 'B' connector and suitable field attachment with 5 KV grade XLPE insulated, PE sheathed, single core copper conductor screened cable as required. |
| 4 | Supply of 16 sqmm, 5 KV grade plug and receptacle of type I, class 'B' connector and suitable field attachment with 5 KV grade XLPE insulated, PE sheathed, single core copper conductor screened cable as required. | Supply of 16 sqmm, 5 KV grade plug and receptacle of type I, class 'B' connector and suitable field attachment with 5 KV grade XLPE insulated, PE sheathed, single core copper conductor screened cable as required. |
| 5 | Supply of mandatory & information signages fascia boards confirming to the requirement laid down in ICAO Annex-14 volume-I & Aerodrome Design manual part IV & V made out of 4mm thick poly carbonate sheet with letters & symbols screen printed on inside of sign face made of self adhesive 3M film applied on the inside face with required colouring. All legends, width & height of each letter shall be in accordance to the concerned ICAO Annex-14 & Aerodrome design manual part IV & V. Details / Type of signages fascia shall be as per site requirement & suitable for replacement of the fascia in the existing sign boards & shall be got approved from EIC before manufacturing etc as required. | Supply of mandatory & information signages fascia boards confirming to the requirement laid down in ICAO Annex-14 volume-I & Aerodrome Design manual part IV & V made out of 4mm thick poly carbonate sheet with letters & symbols screen printed on inside of sign face made of self adhesive 3M film applied on the inside face with required colouring. All legends, width & height of each letter shall be in accordance to the concerned ICAO Annex-14 & Aerodrome design manual part IV & V. Details / Type of signages fascia shall be as per site requirement & suitable for replacement of the fascia in the existing sign boards & shall be got approved from EIC before manufacturing etc as required. |
| 6 | Supply of electronic LED convertor suitable for operation on 2.8- 6.6A AC constant current as incoming supply of the isolating transformers of the AGL series ckt. & suitable for existing Airfield LED signages. | Supply of electronic LED convertor suitable for operation on 2.8- 6.6A AC constant current as incoming supply of the isolating transformers of the AGL series ckt. & suitable for existing Airfield LED signages. |
| 7 | Supply of following rating completely enclosed rubber covered isolating transformer for use in series airport lighting circuits having nominal voltage rating of 5KV and all rated for operation on 50 Hz. The transformer shall be water tight and shall be designed for direct burial in the earth or installation in a base confirming to the specifications, complete as required. | Supply of following rating completely enclosed rubber covered isolating transformer for use in series airport lighting circuits having nominal voltage rating of 5KV and all rated for operation on 50 Hz. The transformer shall be water tight and shall be designed for direct burial in the earth or installation in a base confirming to the specifications, complete as required. |
| 8 | Supply of PAPI lamp holder suitable for 200 W, 6.6/6.6 A AMA make, MK- III PAPI light fittings. | Supply of PAPI lamp holder suitable for 200 W, 6.6/6.6 A AMA make, MK- III PAPI light fittings. |
| 9 | Supply of elevated type LED Taxiway Edge light fitting (MIRL fitting) for use as Taxiway / Apron Edge /Turning Pad lights suitable for operation at 2.8 Amps to 6.6 Amps series circuit supply current complete with suitable LEDs, Omni-directional Blue lens (glass), Lens clamping mechanism, breakable coupling, rings /gaskets, base plate with 06 nos. M-10 stainless steel bolts and including an integrated encapsulated suitable electronic converter with standard secondary lead etc. complete fitting confirming to latest ICAO standards /requirement as required. | Supply of elevated type LED Taxiway Edge light fitting (MIRL fitting) for use as Taxiway / Apron Edge /Turning Pad lights suitable for operation at 2.8 Amps to 6.6 Amps series circuit supply current complete with suitable LEDs, Omni-directional Blue lens (glass), Lens clamping mechanism, breakable coupling, rings /gaskets, base plate with 06 nos. M-10 stainless steel bolts and including an integrated encapsulated suitable electronic converter with standard secondary lead etc. complete fitting confirming to latest ICAO standards /requirement as required. |
| 10 | Supply of 105 Watt. Halogen lamp, 6.6Amp Halogen lamp having minimum rated life of 1000 hours burning at full brilliancy. (For Inset type light suitable for OCEM make SLRE - Runway edge light fitting). Make: Narva, Model No. 6108, Make: OSRAM Model No: 64339 or equivalent. | Supply of 105 Watt. Halogen lamp, 6.6Amp Halogen lamp having minimum rated life of 1000 hours burning at full brilliancy. (For Inset type light suitable for OCEM make SLRE - Runway edge light fitting). Make: Narva, Model No. 6108, Make: OSRAM Model No: 64339 or equivalent. |
| 11 | Supply of 200W, 6.6 A Halogen Lamp - Lead type OSRAM 64382 HLX-C or equivalents Make suitable for OCEM Make, Model: FAU-200 Approach Light Fitting. | Supply of 200W, 6.6 A Halogen Lamp - Lead type OSRAM 64382 HLX-C or equivalents Make suitable for OCEM Make, Model: FAU-200 Approach Light Fitting. |
| 12 | Supply of 150W, 6.6 A EWR Halogen Lamp suitable for elevated type runway edge light fittings of Astronics DME make (Model L-862) of Halogen lamp type 64354 EWR, 150W, 6.6A GY9.5 of OSRAM Make or equivalent. | Supply of 150W, 6.6 A EWR Halogen Lamp suitable for elevated type runway edge light fittings of Astronics DME make (Model L-862) of Halogen lamp type 64354 EWR, 150W, 6.6A GY9.5 of OSRAM Make or equivalent. |
| 13 | Supply of 250 RK 160 RUTTONSHA Thyristor / SCR suitable for Nasu make, 30 KW Constant Current Regulator (CCR). | Supply of 250 RK 160 RUTTONSHA Thyristor / SCR suitable for Nasu make, 30 KW Constant Current Regulator (CCR). |
| 14 | Supply of 150 RK 160 RUTTONSHA Thyristor / SCR suitable for Nasu make, 20 KW Constant Current Regulator (CCR). | Supply of 150 RK 160 RUTTONSHA Thyristor / SCR suitable for Nasu make, 20 KW Constant Current Regulator (CCR). |
| 15 | Supply of 85 RK 160 RUTTONSHA Thyristor / SCR suitable for Nasu make, 7.5 KW Constant Current Regulator (CCR). | Supply of 85 RK 160 RUTTONSHA Thyristor / SCR suitable for Nasu make, 7.5 KW Constant Current Regulator (CCR). |
| 16 | Supply of 65 RK 160 RUTTONSHA Thyristor / SCR suitable for Nasu make, 4 KW Constant Current Regulator (CCR). | Supply of 65 RK 160 RUTTONSHA Thyristor / SCR suitable for Nasu make, 4 KW Constant Current Regulator (CCR). |
| 17 | Calibration of PAPI Clinometer from Govt. approved /NABL certified lab. The items should be Picked up from the airport site and bring back in good position after calibration. | Calibration of PAPI Clinometer from Govt. approved /NABL certified lab. The items should be Picked up from the airport site and bring back in good position after calibration. |
| 18 | Calibration of Lux Meter from Govt. approved /NABL certified lab. The items should be Picked up from the airport site and bring back in good position after calibration. | Calibration of Lux Meter from Govt. approved /NABL certified lab. The items should be Picked up from the airport site and bring back in good position after calibration. |
| 19 | Carrying out /Making in-field measurement of intensity, beam spread and orientation (4C's i.e.- Configuration, Colour, candelas and Coverage) chromaticity, luminous factor, one time field alignment setting for inset/ elevated type approach, inset/elevated type runway edge, elevated runway end, inset/elevated type threshold, PAPI airfields ground lights, replacement of burnt out lamp, lens, filters, any corrective action etc. as required (spares to be provided by AAl) by using vehicle mounted Mobile Testing Equipment system and testing of individual fitting.by frame Reader, submission of test reports etc as per requirement of ICAO/Civil Aviation Requirement (CAR) Section-4 Aerodrome standard & licensing series 'B' Part-I, Technical specification etc. complete as required as per the detail inventory of airfield ground lighting(AGL) fixtures at the Airport.As Per below details: -a) Runway Edge light - 179 Nos. b) Approach light - 136 Nos.c) SAPL lights - 17 Nos.d) PAPI lights - 02 Units.e) Threshold & End lights - 48 Nos.f) Turnpad lights - 60 Nos. | Carrying out /Making in-field measurement of intensity, beam spread and orientation (4C's i.e.- Configuration, Colour, candelas and Coverage) chromaticity, luminous factor, one time field alignment setting for inset/ elevated type approach, inset/elevated type runway edge, elevated runway end, inset/elevated type threshold, PAPI airfields ground lights, replacement of burnt out lamp, lens, filters, any corrective action etc. as required (spares to be provided by AAl) by using vehicle mounted Mobile Testing Equipment system and testing of individual fitting.by frame Reader, submission of test reports etc as per requirement of ICAO/Civil Aviation Requirement (CAR) Section-4 Aerodrome standard & licensing series 'B' Part-I, Technical specification etc. complete as required as per the detail inventory of airfield ground lighting(AGL) fixtures at the Airport.As Per below details: -a) Runway Edge light - 179 Nos. b) Approach light - 136 Nos.c) SAPL lights - 17 Nos.d) PAPI lights - 02 Units.e) Threshold & End lights - 48 Nos.f) Turnpad lights - 60 Nos. |
| 20 | Supply of 4 Head LED Airport rotating beacon set of type L-802A complying to ICAO Annex-14 Para 5.3.3 & FAA : AC 150 / 5345-12 suitable for operation on 220/240V, 50 Hz, single phase AC supply having 04 head, ON/OFF control panel & compatible for ON/OFF of beacon from remote control desk of ATC tower, minimum flash 20 - 30 per minute i/c all the accessories complete as required. | Supply of 4 Head LED Airport rotating beacon set of type L-802A complying to ICAO Annex-14 Para 5.3.3 & FAA : AC 150 / 5345-12 suitable for operation on 220/240V, 50 Hz, single phase AC supply having 04 head, ON/OFF control panel & compatible for ON/OFF of beacon from remote control desk of ATC tower, minimum flash 20 - 30 per minute i/c all the accessories complete as required. |
| 21 | Decorative lighting of Terminal Building and Garden area with 100 pcs PAR lights and 500 pcs fairy/ Rise lights with all accessories, men and materials, wiring and connections etc. complete as required [Occasion up to 3 days = 1 Job].The quantity and colour of LEDs will be decided by Engineer- In - Charge on every occasion. | Decorative lighting of Terminal Building and Garden area with 100 pcs PAR lights and 500 pcs fairy/ Rise lights with all accessories, men and materials, wiring and connections etc. complete as required [Occasion up to 3 days = 1 Job].The quantity and colour of LEDs will be decided by Engineer- In - Charge on every occasion. |
| 22 | Supply of Wind Sock Cloth of color Red & White in the form of a truncated cone made of fabric and should have a length of not less than 3.6m and diameter at larger end of not less than 0.9m confirming to ICAO Annex 14 and Aerodrome Design Manual part-6/FAA. | Supply of Wind Sock Cloth of color Red & White in the form of a truncated cone made of fabric and should have a length of not less than 3.6m and diameter at larger end of not less than 0.9m confirming to ICAO Annex 14 and Aerodrome Design Manual part-6/FAA. |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 19 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 20 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender