Housing Urban and Rular Development Government Departments Closing in 8 days TDR #58055015

Tender For Construction Of Manipuri Youth Hostel At Silchar(Rcc G+1 Storied Building With Provision For Future Extension Along Horizontal And Vertical Direction Upto G+2 Storied)

Issued by Government Departments · Cachar, Assam
Tender Value
1.41 Crore
Estimated cost
Bid Submission
05 Nov 2026
8 days left
EMD
2.83 Lakhs
Bank guarantee accepted
Document Fee
2850
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Cachar → Assam
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Construction Of Manipuri Youth Hostel At Silchar(Rcc G+1 Storied Building With Provision For Future Extension Along Horizontal And Vertical Direction Upto G+2 Storied)

BOQ

Name of Work:- Construction of Manipuri Youth Hostel at Silchar(RCC G+1 Storied building with provision for future extension along horizontal and vertical direction upto G+2 storied)
Sl. No. Item Description
1Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil
2Excavating, supplying and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc. complete.
3Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete.
4Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:3:6 (1 Cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources)
5Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level :1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources)
6Reinforced cement concrete work in walls (any thickness),including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement :1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources)
7Centering and shuttering including strutting, propping etc. and removal of form forFoundations, footings, bases of columns, etc. for mass concrete
8Centering and shuttering including strutting, propping etc. and removal of form for Suspended floors, roofs, landings, balconies and access platform
9Centering and shuttering including strutting, propping etc. and removal of form forLintels, beams, plinth beams, girders, bressumers and cantilevers
10Centering and shuttering including strutting, propping etc. and removal of form forColumns, Pillars, Piers, Abutments, Posts and Struts
11Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level.Thermo-Mechanically Treated bars of grade Fe-500D or more.
12Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level.Thermo-Mechanically Treated bars of grade Fe-500D or more. (ii)Super Ductile (SD) TMT reinforcement bars
13Flat brick Soling
14Brick work with common burnt clay F.P.S. (non modular) bricks of classdesignation 7.5 in foundation and plinth in:Cement mortar 1:4 (1 cement : 4 coarse sand)
15Brick work with common burnt clay F.P.S. (non modular) bricks of classdesignation 7.5 in foundation and plinth in:Cement mortar 1:6 (1 cement : 6 coarse sand)
16Brick work with common burnt clay F.P.S. (non modular) bricks of classdesignation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in :
17Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level.Cement mortar 1:3 (1 cement :3 coarse sand)
18Half brick masonry with common burnt clay F.P.S. (non modular) bricksof class designation 7.5 in superstructure above plinth level up to floorV level.Cement mortar 1:4 (1 cement :4 coarse sand)
19Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete.
20Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters.30 mm thick including ISI marked Stainless Steel butt hinges with necessary screws
21Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete.Fixed to openings /wooden frames with rawl plugs screws etc.
22Providing and fixing bright finished brass butt hinges with necessar screws etc. complete :125x85x5.5 mm (heavy type)
23Providing and fixing bright finished brass butt hinges with necessar screws etc. complete :100x85x5.5 mm (heavy type)
24Providing and fixing bright finished brass butt hinges with necessar screws etc. complete :75x65x4 mm (heavy type)
25Providing and fixing bright finished brass tower bolts (barrel type) with necessary screws etc. complete :200x10 mm
26Providing and fixing bright finished brass tower bolts (barrel type) with necessary screws etc. complete :150x10 mm
27Providing and fixing bright finished brass tower bolts (barrel type) with necessary screws etc. complete :100x10 mm
28Providing and fixing bright finished brass door latch with necessary screws etc. complete :300x16x5 mm
29Providing and fixing bright finished brass door latch with necessary screws etc. complete :250x16x5 mm
30Providing and fixing M.S. Tubular frames for doors, windows, ventilatorsand cupboard with rectangular/ L-Type sections, made of 1.60 mm thickM.S. Sheet, joints mitred, welded and grinded finish, with profiles ofrequired size, including fixing of necessary butt hinges and screws andapplying a priming coat of approved steel primer.Fixing with 15x3 mm lugs 10 cm long embedded in cementconcrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarsesand : 6 graded stone aggregate 20 mm nominal size)
31Providing and fixing 1st quality ceramic glazed floor tiles conforming to IS : 15622 (thickness to be specified by the manufacturer ) of approved make in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:3 (1 cement: 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with pigment of matching shade complete.
32Glazed Vitrified tiles Matt/Antiskid finish of sizeSize of Tile 600 x 600 mm
33Providing and laying flamed finish Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge :Flamed finish granite stone slab Jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent.
34Cement plaster skirting up to 30 cm height, with cement mortar 1:3(1 cement : 3 coarse sand), finished with a floating coat of neat cement.18 mm thick
35CEMENT PLASTER (IN FINE SAND)12 mm cement plaster of mix :1:6 (1 cement: 6 fine sand)
3615 mm cement plaster on rough side of single or half brick wall of mix:1:4 (1 cement: 4 fine sand)
3715 mm cement plaster on the rough side of single or half brick wall of mix :1:6 (1 cement: 6 fine sand)
3820 mm cement plaster on the rough side of single or half brick wall of mix :1:6 (1 cement: 6 fine sand)
39Providing and applying plaster of paris putty of 2 mm thickness overplastered surface to prepare the surface even and smooth complete.
40Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade :New work (two or more coats) over and including water thinnable priming coat with cement primer
41Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two or more coat applied @ 1.67 ltr/10 sqmover and including priming coat of exterior primer applied@ 2.20 kg/10 sqm)
42Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications : Two or more coats applied on walls @ 1.25 ltr/10 sqm over and including one coat of Special primer applied @ 0.75 ltr /10 sqm
43Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer's specifications including appropriate priming coat, preparation of surface, etc. complete.On concrete work
44Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
45Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free,straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) :For fixed portionPowder coated aluminium (minimumthickness of powder coating 50 micron)
46For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately)Powder coated aluminium (minimumthickness of powder coating 50 micron)
47Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 5 mm thickness (weight not less than 12.50 kg/sqm)
48Providing and laying water proofing treatment on roofs of slabs by applying cement slurry mixed with water proofing cement compound consisting of applying:a) after surface preparation, first layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/sqm.(b) laying second layer of Fibre glass cloth when the first layer is still green. Overlaps of joints of fibre cloth should not be lessthan 10 cm. (c) third layer of 1.5 mm thickness consisting of slurry of cement@ 1.289 kg/sqm mixed with water proofing cement compound @ 0.670 kg/sqm and coarse sand @ 1.289 kg/sqm. This will be allowed to air cure for 4 hours followed by water curing for48 hours. The entire treatment will be taken upto 30 cm on parapet wall and tucked into groove in parapet all around.(d) fourth and final layer of brick tiling with cement mortar (which will be paid for separately.For the purpose of measurement the entire treated surface will be measured.
49Supplying at site :R.C.C. Standards post/ struts/rails/ pales of mix 1:1.5:3(1 cement : 1.5 coarsesand : 3 graded stone aggregate12.5 mm nominal size) with wooden plugs or 6mm barnibs wherever required as per direction of Engineer-incharge(cost of earth works in excavation, concrete worksin foundation to be paid separately).
50Fencing with R.C.C. post placed at required distance, embedded incement concrete blocks, every 15th post, last but one end post andcorner post shall be strutted on both sides and end post one sideonly, provided with horizontal lines and two diagonals of barbed wireweighing 9.38 kg per 100 metres (minimum), between the two postsfitted and fixed with G.I. staples on wooden plugs or G.I. binding wiretied to 6 mm bar nibs fixed while casting the post (cost of R.C.C.posts, struts, earth work and concrete to be paid for separately) :-Payment to be made per metre cost of total length of barbed wireused.With G.I. barbed wire
51Supplying at site Angle iron post & strut of required size includingbottom to be split and bent at right angle in opposite direction for 10cm length and drilling holes upto 10 mm dia. etc. complete.
52Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever requiredW.C. pan with ISI marked white solid plastic seat and lid
53Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require:White Vitreous China Flat back wash basin size 550x400 mm with single 15 mm C.P. brass pillar tap
54Providing and fixing CP Brass 32mm size Bottle Trap of approved quality & make and as per the direction of Engineer-in-charge.
55Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete.
56Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:893115 mm nominal bore
57Providing and fixing toilet paper holder.C.P. brass
58Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required :Kitchen sink with drain board510x1040 mm bowl depth 250 mm
59Providing and fixing PTMT liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour, weighing not less than 105 gms.
60Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm or 340x410x265 mm sizes respectively.
61Providing and fixing soil, waste and vent pipes :100 mm diaSand cast iron S&S pipe as per IS: 1729
6275mm ODSand cast iron S&S pipe as per IS: 1729
63Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete.Semi Rigid Pipe40 mm od PVC pipe
64Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge.Concealed work, including cutting chases and making good the walls20 mm dia nominal bore
65Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge.Concealed work, including cutting chases and making good the walls25 mm dia nominal bore
66Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge.Concealed work, including cutting chases and making good the walls32 mm dia nominal bore
67Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.Internal Work - Exposed on wall25 mm dia nominal bore
68Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.Internal Work - Exposed on wall40 mm dia nominal bore
69Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.Internal Work - Exposed on wall50 mm dia nominal bore
70Providing and fixing gun metal gate valve with C.I wheel of approved quality25 mm nominal bore
71Providing and fixing gun metal gate valve with C.I wheel of approved quality32 mm nominal bore
72Providing and fixing G.I. pipes complete with G.I. fittings and clamps, i/c cutting and making good the walls etc.Internal Work - Exposed on wall32 mm dia nominal bore
73Painting G.I. pipes and fittings with synthetic enamel white paint with two coats over a ready mixed priming coat, both of approved quality for new work :32 mm diameter pipe
74Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.
75Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931 : 15 mm nominal bore
76Providing and fixing C.P. brass long nose bib cock of approved quality conforming to IS standards and weighing not less than 810 gms.15 mm nominal bore
77Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms.15 mm nominal bore
78Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931.15 mm nominal bore
79Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:893115mm nominal bore
80Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer-in-charge, upto 90 metre depth below ground level. All types of soil 300 mm dia
81Supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized PVC medium well casing (CM) pipe of required dia, conforming to IS: 12818, including required hire and labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer -in-charge. 100 mm nominal size dia
82Supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized PVC medium well casing (CM) pipe of required dia, conforming to IS: 12818, including required hire and labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer -in-charge. 150 mm nominal size dia
83Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. (SUCTION PIPE) External work 40 mm nominal outer dia Pipes
84Providing and placing in position filters of 40 mm diameter G.I./ PVC pipe with brass strainer of approved quality.
85Providing and fixing gun metal non- return valve of approved quality (screwed end) :40 mm nominal bore Horizontal
86Providing and fixing gun metal non- return valve of approved quality (screwed end) :40 mm nominal bore Vertical
87Development of tube well in accordance with IS : 2800 (part I) and IS: 11189, to establish maximum rate of usable water yield without sand content (beyond permissible limit), with required capacity air compressor, running the compressor for required time till well is fully developed, measuring yield of well by “V” notch method or any other approved method, measuring static level & draw down etc. by step draw down method, collecting water samples & getting tested in approved laboratory, i/c disinfection of tubewell, all complete, including hire & labour charges of air compressor, tools & accessories etc., all as per requirement and direction of Engineer-in-charge.
88Gravel packing in tubewell construction in accordance with IS: 4097, including providing gravel fine/ medium/ coarse, in required grading & sizes as per actual requirement, all complete as per direction of Engineer-in-charge.
89Providing and fixing suitable size threaded mild steel cap or spot welded plate to the top of bore well housing/ casing pipe, removable as per requirement, all complete for borewell of:100 mm dia
90Providing and fixing suitable size threaded mild steel cap or spot welded plate to the top of bore well housing/ casing pipe, removable as per requirement, all complete for borewell of:150 mm dia
91Providing and fixing M.S. clamp of required dia to the top of casing/ housing pipe of tubewell as per IS: 2800 (part I), including necessary bolts & nuts of required size complete.150 mm clamp
92Providing and fixing Bail plug/ Bottom plug of required dia to the bottom of pipe assembly of tubewell as per IS:2800 (part I).100 mm dia
93Providing and fixing Bail plug/ Bottom plug of required dia to the bottom of pipe assembly of tubewell as per IS:2800 (part I).150 mm dia.
94Supplying including installation, connection as approved by the Deptt., testing and commissioning of SUBMERSIBLE PUMP SET 3 (Three Phase) with submersible cable complete as directed and specified by the deptt.Three phase Submersible motor pump set (Texmo / Crompton Greaves/ Aquatic/ CRI/ V-Guar suitable for 100 mm bore well and above. 1 HP STAGE 5 to 18 with MCB controlled Submersible motor pump set control panel.
95Brick work with common burnt clay F.P.S. (non modular) bricks of classdesignation 7.5 in superstructure above plinth level up to floor V level inall shapes and sizes in :
96Supply, Installation, Fixing of DRY CHEMICAL POWDER Fire Extinguisher confirming to IS: 15683 : 2006 with ISI mark and 120 gm CO2 cartridge will be confirming to IS: 4947 with ISI mark Sodium base dry chemical Powder will be confirming to IS: 4308 withISI Mark, Fire rating class 2A,55B. (4 KG)
97Supply, Installation, Fixing of Carbon Dioxide Fire Extinguisher confirming to IS : 15683 with ISI Mark (Extinguishers will be TROLLEY MOUNTED) 6.5 KG capacity complete in all respect.
981.10 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required 1.10.3 Group C
997.1 Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. 7.1.1 Upto 35 sq. Mm
1007.1 Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. 7.1.3 Above 95 sq. mm and upto 185 sq. Mm
1019.1 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 9.1.33 4 X 16 sq. mm (28mm)
1029.1 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 9.1.34 4 X 25sq. mm (28mm)
1039.1 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 9.1.35 4 X 35 sq. mm (32mm)
10414.13 Providing,laying and fixing following dia G.I pipe(medium class)in ground complete with G.I fitting including trenching(75 cm deep )and refilling as required. 14.13.4 150 mm dia
1051.12 Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.
1061.13 Wiring for light/ power plug with 4X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 2 Nos 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.
1071.14 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 1.14.2 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
1081.14 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.1.14.3 2 X 4 sq. mm + 1 X 4 sq. mm earth wire
1091.14 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.1.14.10 4 X 6 sq. mm + 2 X 6 sq. mm earth wire
1101.25 Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required
1111.26 Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required
1121.31 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required
1131.32 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required.
1141.45 Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable, including providing and fixing phenolic laminated sheet cover on the fan box etc. as required.
1151.50 Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required. 1.50.1 Upto 450 mm sweep
1161.55 Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point (without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required. 1.55.3 Group C
1172.2 Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. 2.2.1 100 A, 16 kA,TPMCCB
1182.2 Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. 2.2.2 125 A, 16 kA,TPMCCB
1192.3 Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 2.3.2 8 way , Double door
1202.3 Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)2.3.3 12 way, Double door
1212.14 Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. 25 amps
1222.5 Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A, tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer) as required. (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.) 2.5.1 4 way (4 + 12), Double door
1232.10 Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. 2.10.1 Single pole
1242.10 Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. 2.10.3Double Pole
1252.15 Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. 2.15.3 63A
1262.16 Supplying and fixing DP sheet steel enclosure on surface/ recess along with 25/32 A, 240 V “C” curve DP MCB complete with connections, testing and commissioning etc. as required.
1272.21 Providing and fixing M.V. danger notice plate of 200 mm X 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required.
1281.18 Supplying and drawing following pair 0.5 sq mm FR PVC insulated annealed copper conductor, unarmored telephone cable in the existing surface/ recessed steel/ PVC conduit as required. 1.18.2 2 Pair
1291.21 Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 1.21.2 25 mm
1305.2 Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required.
1315.6 Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
1325.7 Supplying and laying 6 SWG G.I. wire at 0.50 metre below ground level for conductor earth electrode, including connection/ termination with GI thimble etc. as required.
1335.12 Providing and laying earth connection from earth electrode with 6 SWG dia G.I. Wire in 15 mm dia G.I. pipe from earth electrode including connection with G.I. thimble excavation and re-filling as required.
1345.16 Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required.
1356.7 Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or on surface of wall for lightning conductor complete as required.(For horizontal run)
1366.8 Providing and fixing GI tape 20 mm x 3 mm thick on parapet or surface of wall for lighting conductor complete as required. ( For vertical run )
1376.2 Providing and fixing of lightning conductor finials made of 25 mm dia 300 mm long, GI tube, having single point at the top with 85 mm dia 6 mm thick GI base plate including holes etc complete as required.
1386.12 Providing and fixing testing joint, made of 20 mm x 3 mm thick GI strip, 125 mm long with 4 nos. of GI bolts, nuts, and spring washers etc as required.
1391.41 Installation ,testing commissioning of prewired fluorescent/compact fitting of all types complete with all accessories and tube etc.directly on ceiling/wall including connection with 1.5 sq.mm FRLS PVC insulated copper conductor ,single core cable and earthing etc.as required
1402.5 Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 volts, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 amps tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCB's (but without MCB's and incomer ) as required . (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required. 2.5.3 12 way (4 + 36), Double door
141Wall bracket (N/S)
142Batten and Tube LED 20W (N/S)
143e Supplying including fitting fixing of following A.C. Ceiling fan complete with all accessories like down rod, canopy etc. of following sweeps with making necessary connection as approved by the Deptt.)as required complete and as directed by the Department [Without regulator]. Premium model 1200 mm Sweep (N/S)
144High Speed 225 mm sweep (ORIENT make), Trans Air 225 mm sweep (Crompton make), Ventil Air DX 250 mm sweep Louver type (Havells make)
145Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required.Upto 35 sq. Mm
146Supplying and drawing following sizes of FRLS PVC insulated copper conductor single core cable in PVC conduit2x2.5 sq.mm
147Supplying and drawing following sizes of FRLS PVC insulated copper conductor single core cable in PVC conduit4x6 sq.mm
148Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required.
149Supplying and laying 6 SWG G.I. wire at 0.50 metre below ground level for conductor earth electrode, including connection/ termination with GI thimble etc. as required.
150Providing and laying earth connection from earth electrode with 6 SWG dia G.I. Wire in 15 mm dia G.I. pipe from earth electrode including connection with G.I. thimble excavation and re-filling as required.
151Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required.
152Supply of 45 W LED(NEXUS NEO LED) street light made of pressure die cast Aluminium Housing with toughened glass and high power LEDs and secondary lenses with IP66 .System efficiency>=110LPW. Option for 3000K 10KV SPD included. Crompton or equivalent make. Please Enable Macros to View BoQ information
153Supply of 45 W LED(NEXUS NEO LED) street light made of pressure die cast Aluminium Housing with toughened glass and high power LEDs and secondary lenses with IP66 .System efficiency>=110LPW. Option for 3000K 10KV SPD included. Crompton or equivalent make. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 58055015
AUTHORITY Government Departments
TENDER VALUE 1.41 Crore
LAST DATE 05-11-2026
Authority
Authority Name Public Works Building And Nh Department
Work Description Tender for Construction Of Manipuri Youth Hostel At Silchar(Rcc G+1 Storied Building With Provision For Future Extension Along Horizontal And Vertical Direction Upto G+2 Storied)
Basic Detail
Tender No SBC/CS/2026-27/13
Bidding Type Tender
Location
City Cachar
State Assam
Key Dates
Publish Date 15 Oct 2026
Submission Date 05 Nov 2026
Open Date 05 Nov 2026
Finance
Tender Value 1.41 Crore
Tender Fee 2850
EMD 2.83 Lakhs
Exemption Available
Document List
10540e66-fac4-4bed-915e-9f1d3cf921e1.html
BOQ_85494.xls
FOB.pdf
OFFICEMEMORANDUMFORONLINE_1.pdf
SBDManipuriBoysHostel.pdf
Tendernotice_1.pdf
Tendernotice_2.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Oct 15, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Nov 05, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 8 days
Nov 05, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 8 days

Tender Documents

Download All (ZIP) ↓
html

10540e66-fac4-4bed-915e-9f1d3cf921e1.html

xls

BOQ_85494.xls

pdf

FOB.pdf

pdf

OFFICEMEMORANDUMFORONLINE_1.pdf

pdf

SBDManipuriBoysHostel.pdf

pdf

Tendernotice_1.pdf

pdf

Tendernotice_2.pdf