Petroleum and Natural Gas Boards / Undertakings / PSU Closing in 1 days TDR #58054993

Tender For Provision Of Linear Led Lights Including Replacement Of Existing False Ceiling And Allied Works For A Site Retail Outlets Of Tinsukia Divisional Office Under Indianoil Aod State Office.Lot 1 Ros:20. Hill Service Station (8X16 M)30. Ladulal

Issued by Boards / Undertakings / PSU · Tinsukia, Assam
Tender Value
Ref. Documents
Estimated cost
Bid Submission
22 Oct 2026
1 days left
EMD
Ref. Documents
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Tinsukia → Assam
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Provision Of Linear Led Lights Including Replacement Of Existing False Ceiling And Allied Works For A Site Retail Outlets Of Tinsukia Divisional Office Under Indianoil Aod State Office.Lot 1 Ros:20. Hill Service Station (8X16 M)30. Ladulal Jain & Sons(Numaligarh) (17X21 M)40. Ladulal Jain & Sons(Silonijan) (12X29 M)50. Noklak Filling Station (12X8 M)60. Bohana Kisan Sewa Kendra (8X16 M)70. Sonowal & Sons Pol - Agro Serv (16X8 M)80. Northern Highway Gas Station (12X16 M)90. Skv Enterprise (11X20 M)120. Mebo Automobiles (Adhoc) (12X19 M)130. Patchup Filling Station (15X8 M)160. Leinak Pump Agency (16X8 M)190. Universal Agencies(Badulipar) (17X7)210. G. B. Filling Station (8X17)Lot 2 Ros:10. Nirada Fuel Service Station (12X27 M)100. Machkhowa Kisan Seva Kendra (16X8 M)110. repair renovation & Co. Pvt. Ltd. (N. Lakhimpur) (14X8 M)140. Pasighat Service Station (16X8 M)150. Wangnao Fuel Station (11X14 M)170. Saligram Bridhichand & Co.- Hansara (18X8 M)180. Wakro Service Station (17X8 M)200. Maa Service Station (12X17)

BOQ

Name of Work:- Provision of Linear LED lights including replacement of existing False Ceiling and allied works for A site retail outlets of Tinsukia Divisional office under IndianOil AOD state office.LOT 1 ROs:20. HILL SERVICE STATION (8X16 M)30. LADULAL JAIN & SONS(Numaligarh) (17X21 M)40. LADULAL JAIN & SONS(SILONIJAN) (12X29 M)50. NOKLAK FILLING STATION (12X8 M)60. BOHANA KISAN SEWA KENDRA (8X16 M)70. SONOWAL & SONS POL - AGRO SERV (16X8 M)80. NORTHERN HIGHWAY GAS STATION (12X16 M)90. SKV ENTERPRISE (11X20 M)120. Mebo Automobiles (Adhoc) (12X19 M)130. PATCHUP FILLING STATION (15X8 M)160. LEINAK PUMP AGENCY (16X8 M)190. UNIVERSAL AGENCIES(BADULIPAR) (17x7)210. G. B. FILLING STATION (8x17)LOT 2 ROs:10. NIRADA FUEL SERVICE STATION (12X27 M)100. MACHKHOWA KISAN SEVA KENDRA (16X8 M)110. R.R & CO. PVT. LTD. (N. LAKHIMPUR) (14X8 M)140. PASIGHAT SERVICE STATION (16X8 M)150. WANGNAO FUEL STATION (11X14 M)170. SALIGRAM BRIDHICHAND & CO.- HANSARA (18X8 M)180. WAKRO SERVICE STATION (17X8 M)200. MAA SERVICE STATION (12x17)
Sl. No. Item Description
1NIRADA FUEL SERVICE STATION (12X27 M)
2Providing and fixing 150F/200F flush panel,(pre-coated steel) False Ceiling made of Cold rolled steel sheet conforming to IS 513, having minimum yield stress and tensile stress as 240 Mpa and 300 Mpa respectively. Base metal thickness for ceiling panel and Carriers shall be 0.45mm and 0.55mm respectively. The steel surface shall have hot dip metallic coated with Zinc coating (galvanizing) as per IS277, with total mass of coating on both sides shall be 120 gms/sqm. The steel shall have organic coating with Regular Modified Polyester (RMP) paint on continues coil coating line. The thickness of coating on top side shall be 20-25 Microns (i.e. 15-18 microns RMP paint, over 5-7 microns epoxy primer) and back side 8-10 Microns RMP paint over epoxy primer. Total Coated Thickness (TCT) shall be 0.50 MM for Ceiling panel and 0.60 MM for Carrier. Sheet shall have protective Sheet shall have protective guard film of thickness of 25 microns minimum to avoid scratches while transportation and should be supplied in single length up to 6m (for panel) and up to 5m (for carrier) or as desired by Engineer-in-charge. The ceiling panel shall be clipped into carriers which are suspended from steel trusses/purlins with the help of GI suspension angle of size 25x25x0.5mm thick by means of rigid suspension system meant for exterior. The longitudinal joints of two panels shall be butt joined with a special type of panel splice to be fixed from inner side. The carrier will be joined with carrier splices maintaining a module of 150 mm. The spans shall not exceed as recommended and manufacturer recommendations shall be followed on installation procedure.
3Supply and fixing of Linear Recessed mounted LED (Light Emitting Diode) Light fittings of size 2400mm and 80 Watt, having IP 65 protection class with Pressure Die Cast Aluminium housing and with Polycarbonate diffuser of approved make or equivalent as per direction of Engineer-in-charge. High Efficiency Translucence(HET) diffuser. Colour Rendering Index CRI>80, Temp-0 to 45 Deg C, Driver efficiency>85%, THD < 10%, CCT- 6500 K Powerfactor>0.95, Surge protection-2 kV, Multistage Isolated Constant Current-Constant Voltage operated driver with range 140-270V AC and Safety Extra Low Voltage Safe level < 60V DC as per IEC standard, Luminaire lumen ≥ 2100lm. Each lot of Fittings shall have serial numbers & accompany LM79 / IS 16106 test reports and reference/batch nos of LEDs and fittings for verification at site. The supply of LED lighting shall be covered by a warranty of at least 72 months from the date of supply of the lighting and the LED light fitting shall be complete in all respects including LED, LED Driver, Electronic circuitory, Luminarie etc
4CABLING AND ALLIED WORKS - ARMOURED CABLES Supply & laying of XLPE insulated PVC sheathed aluminium/copper conductor, 1.1 kV grade armoured cable conforming to IS:7098, as per approved make in ground/ trench/surface/pipe, etc. whereever required as per direction of Engineer In-charge. Note: The rate of Installation should be inclusive of Cable clamps, tags Saddles, Consumables etc. Trays/pipes, trenches, fabricated tray supports etc will be covered & paid in Separate Items
5iii) 3 Core x 1.5 sq. mm. (copper)
6iv) 3 Core x 2.5 sq. mm Copper Cable FRLS
7CABLE TERMINATION GLANDS NON-FLP HEAVY DUTY DOUBLE COMPRESSION Cable Termination (NON FLP): Providing termination of 1.1 kV grade armoured cable for the following sizes including supply of NON FLP heavy duty Double Compresson cable glands, crimping type lugs and allied jointing materials, etc. all complete as per specification and direction of Engineer In-charge. Glands and lugs shall be of approved make. Copper lugs for copper cables and aluminium lugs for aluminium cables shall be used.
8vi) 3 Core x 1.5 sq. mm.
9vii) 3 Core x 2.5 sq. mm
10Dismantling roofing including ridges, hips valleys & gutters, False ceiling of any type and stacking the material within premises, of:
11i) G.S. Sheet/ Klippon galvalume sheet/ False ceiling panels
12HILL SERVICE STATION (8X16 M)
13Providing and fixing 150F/200F flush panel,(pre-coated steel) False Ceiling made of Cold rolled steel sheet conforming to IS 513, having minimum yield stress and tensile stress as 240 Mpa and 300 Mpa respectively. Base metal thickness for ceiling panel and Carriers shall be 0.45mm and 0.55mm respectively. The steel surface shall have hot dip metallic coated with Zinc coating (galvanizing) as per IS277, with total mass of coating on both sides shall be 120 gms/sqm. The steel shall have organic coating with Regular Modified Polyester (RMP) paint on continues coil coating line. The thickness of coating on top side shall be 20-25 Microns (i.e. 15-18 microns RMP paint, over 5-7 microns epoxy primer) and back side 8-10 Microns RMP paint over epoxy primer. Total Coated Thickness (TCT) shall be 0.50 MM for Ceiling panel and 0.60 MM for Carrier. Sheet shall have protective Sheet shall have protective guard film of thickness of 25 microns minimum to avoid scratches while transportation and should be supplied in single length up to 6m (for panel) and up to 5m (for carrier) or as desired by Engineer-in-charge. The ceiling panel shall be clipped into carriers which are suspended from steel trusses/purlins with the help of GI suspension angle of size 25x25x0.5mm thick by means of rigid suspension system meant for exterior. The longitudinal joints of two panels shall be butt joined with a special type of panel splice to be fixed from inner side. The carrier will be joined with carrier splices maintaining a module of 150 mm. The spans shall not exceed as recommended and manufacturer recommendations shall be followed on installation procedure.
14Supply and fixing of Linear Recessed mounted LED (Light Emitting Diode) Light fittings of size 2400mm and 80 Watt, having IP 65 protection class with Pressure Die Cast Aluminium housing and with Polycarbonate diffuser of approved make or equivalent as per direction of Engineer-in-charge. High Efficiency Translucence(HET) diffuser. Colour Rendering Index CRI>80, Temp-0 to 45 Deg C, Driver efficiency>85%, THD < 10%, CCT- 6500 K Powerfactor>0.95, Surge protection-2 kV, Multistage Isolated Constant Current-Constant Voltage operated driver with range 140-270V AC and Safety Extra Low Voltage Safe level < 60V DC as per IEC standard, Luminaire lumen ≥ 2100lm. Each lot of Fittings shall have serial numbers & accompany LM79 / IS 16106 test reports and reference/batch nos of LEDs and fittings for verification at site. The supply of LED lighting shall be covered by a warranty of at least 72 months from the date of supply of the lighting and the LED light fitting shall be complete in all respects including LED, LED Driver, Electronic circuitory, Luminarie etc
15CABLING AND ALLIED WORKS - ARMOURED CABLES Supply & laying of XLPE insulated PVC sheathed aluminium/copper conductor, 1.1 kV grade armoured cable conforming to IS:7098, as per approved make in ground/ trench/surface/pipe, etc. whereever required as per direction of Engineer In-charge. Note: The rate of Installation should be inclusive of Cable clamps, tags Saddles, Consumables etc. Trays/pipes, trenches, fabricated tray supports etc will be covered & paid in Separate Items
16iii) 3 Core x 1.5 sq. mm. (copper)
17iv) 3 Core x 2.5 sq. mm Copper Cable FRLS
18CABLE TERMINATION GLANDS NON-FLP HEAVY DUTY DOUBLE COMPRESSION Cable Termination (NON FLP): Providing termination of 1.1 kV grade armoured cable for the following sizes including supply of NON FLP heavy duty Double Compresson cable glands, crimping type lugs and allied jointing materials, etc. all complete as per specification and direction of Engineer In-charge. Glands and lugs shall be of approved make. Copper lugs for copper cables and aluminium lugs for aluminium cables shall be used.
19vi) 3 Core x 1.5 sq. mm.
20vii) 3 Core x 2.5 sq. mm
21Dismantling roofing including ridges, hips valleys & gutters, False ceiling of any type and stacking the material within premises, of:
22i) G.S. Sheet/ Klippon galvalume sheet/ False ceiling panels
23LADULAL JAIN & SONS (Numaligarh) (17X21 M)
24Providing and fixing 150F/200F flush panel,(pre-coated steel) False Ceiling made of Cold rolled steel sheet conforming to IS 513, having minimum yield stress and tensile stress as 240 Mpa and 300 Mpa respectively. Base metal thickness for ceiling panel and Carriers shall be 0.45mm and 0.55mm respectively. The steel surface shall have hot dip metallic coated with Zinc coating (galvanizing) as per IS277, with total mass of coating on both sides shall be 120 gms/sqm. The steel shall have organic coating with Regular Modified Polyester (RMP) paint on continues coil coating line. The thickness of coating on top side shall be 20-25 Microns (i.e. 15-18 microns RMP paint, over 5-7 microns epoxy primer) and back side 8-10 Microns RMP paint over epoxy primer. Total Coated Thickness (TCT) shall be 0.50 MM for Ceiling panel and 0.60 MM for Carrier. Sheet shall have protective Sheet shall have protective guard film of thickness of 25 microns minimum to avoid scratches while transportation and should be supplied in single length up to 6m (for panel) and up to 5m (for carrier) or as desired by Engineer-in-charge. The ceiling panel shall be clipped into carriers which are suspended from steel trusses/purlins with the help of GI suspension angle of size 25x25x0.5mm thick by means of rigid suspension system meant for exterior. The longitudinal joints of two panels shall be butt joined with a special type of panel splice to be fixed from inner side. The carrier will be joined with carrier splices maintaining a module of 150 mm. The spans shall not exceed as recommended and manufacturer recommendations shall be followed on installation procedure.
25Supply and fixing of Linear Recessed mounted LED (Light Emitting Diode) Light fittings of size 2400mm and 80 Watt, having IP 65 protection class with Pressure Die Cast Aluminium housing and with Polycarbonate diffuser of approved make or equivalent as per direction of Engineer-in-charge. High Efficiency Translucence(HET) diffuser. Colour Rendering Index CRI>80, Temp-0 to 45 Deg C, Driver efficiency>85%, THD < 10%, CCT- 6500 K Powerfactor>0.95, Surge protection-2 kV, Multistage Isolated Constant Current-Constant Voltage operated driver with range 140-270V AC and Safety Extra Low Voltage Safe level < 60V DC as per IEC standard, Luminaire lumen ≥ 2100lm. Each lot of Fittings shall have serial numbers & accompany LM79 / IS 16106 test reports and reference/batch nos of LEDs and fittings for verification at site. The supply of LED lighting shall be covered by a warranty of at least 72 months from the date of supply of the lighting and the LED light fitting shall be complete in all respects including LED, LED Driver, Electronic circuitory, Luminarie etc
26CABLING AND ALLIED WORKS - ARMOURED CABLES Supply & laying of XLPE insulated PVC sheathed aluminium/copper conductor, 1.1 kV grade armoured cable conforming to IS:7098, as per approved make in ground/ trench/surface/pipe, etc. whereever required as per direction of Engineer In-charge. Note: The rate of Installation should be inclusive of Cable clamps, tags Saddles, Consumables etc. Trays/pipes, trenches, fabricated tray supports etc will be covered & paid in Separate Items
27iii) 3 Core x 1.5 sq. mm. (copper)
28iv) 3 Core x 2.5 sq. mm Copper Cable FRLS
29CABLE TERMINATION GLANDS NON-FLP HEAVY DUTY DOUBLE COMPRESSION Cable Termination (NON FLP): Providing termination of 1.1 kV grade armoured cable for the following sizes including supply of NON FLP heavy duty Double Compresson cable glands, crimping type lugs and allied jointing materials, etc. all complete as per specification and direction of Engineer In-charge. Glands and lugs shall be of approved make. Copper lugs for copper cables and aluminium lugs for aluminium cables shall be used.
30vi) 3 Core x 1.5 sq. mm.
31vii) 3 Core x 2.5 sq. mm
32Dismantling roofing including ridges, hips valleys & gutters, False ceiling of any type and stacking the material within premises, of:
33i) G.S. Sheet/ Klippon galvalume sheet/ False ceiling panels
34LADULAL JAIN & SONS (SILONIJAN) (12X29 M)
35Providing and fixing 150F/200F flush panel,(pre-coated steel) False Ceiling made of Cold rolled steel sheet conforming to IS 513, having minimum yield stress and tensile stress as 240 Mpa and 300 Mpa respectively. Base metal thickness for ceiling panel and Carriers shall be 0.45mm and 0.55mm respectively. The steel surface shall have hot dip metallic coated with Zinc coating (galvanizing) as per IS277, with total mass of coating on both sides shall be 120 gms/sqm. The steel shall have organic coating with Regular Modified Polyester (RMP) paint on continues coil coating line. The thickness of coating on top side shall be 20-25 Microns (i.e. 15-18 microns RMP paint, over 5-7 microns epoxy primer) and back side 8-10 Microns RMP paint over epoxy primer. Total Coated Thickness (TCT) shall be 0.50 MM for Ceiling panel and 0.60 MM for Carrier. Sheet shall have protective Sheet shall have protective guard film of thickness of 25 microns minimum to avoid scratches while transportation and should be supplied in single length up to 6m (for panel) and up to 5m (for carrier) or as desired by Engineer-in-charge. The ceiling panel shall be clipped into carriers which are suspended from steel trusses/purlins with the help of GI suspension angle of size 25x25x0.5mm thick by means of rigid suspension system meant for exterior. The longitudinal joints of two panels shall be butt joined with a special type of panel splice to be fixed from inner side. The carrier will be joined with carrier splices maintaining a module of 150 mm. The spans shall not exceed as recommended and manufacturer recommendations shall be followed on installation procedure.
36Supply and fixing of Linear Recessed mounted LED (Light Emitting Diode) Light fittings of size 2400mm and 80 Watt, having IP 65 protection class with Pressure Die Cast Aluminium housing and with Polycarbonate diffuser of approved make or equivalent as per direction of Engineer-in-charge. High Efficiency Translucence(HET) diffuser. Colour Rendering Index CRI>80, Temp-0 to 45 Deg C, Driver efficiency>85%, THD < 10%, CCT- 6500 K Powerfactor>0.95, Surge protection-2 kV, Multistage Isolated Constant Current-Constant Voltage operated driver with range 140-270V AC and Safety Extra Low Voltage Safe level < 60V DC as per IEC standard, Luminaire lumen ≥ 2100lm. Each lot of Fittings shall have serial numbers & accompany LM79 / IS 16106 test reports and reference/batch nos of LEDs and fittings for verification at site. The supply of LED lighting shall be covered by a warranty of at least 72 months from the date of supply of the lighting and the LED light fitting shall be complete in all respects including LED, LED Driver, Electronic circuitory, Luminarie etc
37CABLING AND ALLIED WORKS - ARMOURED CABLES Supply & laying of XLPE insulated PVC sheathed aluminium/copper conductor, 1.1 kV grade armoured cable conforming to IS:7098, as per approved make in ground/ trench/surface/pipe, etc. whereever required as per direction of Engineer In-charge. Note: The rate of Installation should be inclusive of Cable clamps, tags Saddles, Consumables etc. Trays/pipes, trenches, fabricated tray supports etc will be covered & paid in Separate Items
38iii) 3 Core x 1.5 sq. mm. (copper)
39iv) 3 Core x 2.5 sq. mm Copper Cable FRLS
40CABLE TERMINATION GLANDS NON-FLP HEAVY DUTY DOUBLE COMPRESSION Cable Termination (NON FLP): Providing termination of 1.1 kV grade armoured cable for the following sizes including supply of NON FLP heavy duty Double Compresson cable glands, crimping type lugs and allied jointing materials, etc. all complete as per specification and direction of Engineer In-charge. Glands and lugs shall be of approved make. Copper lugs for copper cables and aluminium lugs for aluminium cables shall be used.
41vi) 3 Core x 1.5 sq. mm.
42vii) 3 Core x 2.5 sq. mm
43Dismantling roofing including ridges, hips valleys & gutters, False ceiling of any type and stacking the material within premises, of:
44i) G.S. Sheet/ Klippon galvalume sheet/ False ceiling panels
45NOKLAK FILLING STATION (12X8 M)
46Providing and fixing 150F/200F flush panel,(pre-coated steel) False Ceiling made of Cold rolled steel sheet conforming to IS 513, having minimum yield stress and tensile stress as 240 Mpa and 300 Mpa respectively. Base metal thickness for ceiling panel and Carriers shall be 0.45mm and 0.55mm respectively. The steel surface shall have hot dip metallic coated with Zinc coating (galvanizing) as per IS277, with total mass of coating on both sides shall be 120 gms/sqm. The steel shall have organic coating with Regular Modified Polyester (RMP) paint on continues coil coating line. The thickness of coating on top side shall be 20-25 Microns (i.e. 15-18 microns RMP paint, over 5-7 microns epoxy primer) and back side 8-10 Microns RMP paint over epoxy primer. Total Coated Thickness (TCT) shall be 0.50 MM for Ceiling panel and 0.60 MM for Carrier. Sheet shall have protective Sheet shall have protective guard film of thickness of 25 microns minimum to avoid scratches while transportation and should be supplied in single length up to 6m (for panel) and up to 5m (for carrier) or as desired by Engineer-in-charge. The ceiling panel shall be clipped into carriers which are suspended from steel trusses/purlins with the help of GI suspension angle of size 25x25x0.5mm thick by means of rigid suspension system meant for exterior. The longitudinal joints of two panels shall be butt joined with a special type of panel splice to be fixed from inner side. The carrier will be joined with carrier splices maintaining a module of 150 mm. The spans shall not exceed as recommended and manufacturer recommendations shall be followed on installation procedure.
47Supply and fixing of Linear Recessed mounted LED (Light Emitting Diode) Light fittings of size 2400mm and 80 Watt, having IP 65 protection class with Pressure Die Cast Aluminium housing and with Polycarbonate diffuser of approved make or equivalent as per direction of Engineer-in-charge. High Efficiency Translucence(HET) diffuser. Colour Rendering Index CRI>80, Temp-0 to 45 Deg C, Driver efficiency>85%, THD < 10%, CCT- 6500 K Powerfactor>0.95, Surge protection-2 kV, Multistage Isolated Constant Current-Constant Voltage operated driver with range 140-270V AC and Safety Extra Low Voltage Safe level < 60V DC as per IEC standard, Luminaire lumen ≥ 2100lm. Each lot of Fittings shall have serial numbers & accompany LM79 / IS 16106 test reports and reference/batch nos of LEDs and fittings for verification at site. The supply of LED lighting shall be covered by a warranty of at least 72 months from the date of supply of the lighting and the LED light fitting shall be complete in all respects including LED, LED Driver, Electronic circuitory, Luminarie etc
48CABLING AND ALLIED WORKS - ARMOURED CABLES Supply & laying of XLPE insulated PVC sheathed aluminium/copper conductor, 1.1 kV grade armoured cable conforming to IS:7098, as per approved make in ground/ trench/surface/pipe, etc. whereever required as per direction of Engineer In-charge. Note: The rate of Installation should be inclusive of Cable clamps, tags Saddles, Consumables etc. Trays/pipes, trenches, fabricated tray supports etc will be covered & paid in Separate Items
49iii) 3 Core x 1.5 sq. mm. (copper)
50iv) 3 Core x 2.5 sq. mm Copper Cable FRLS
51CABLE TERMINATION GLANDS NON-FLP HEAVY DUTY DOUBLE COMPRESSION Cable Termination (NON FLP): Providing termination of 1.1 kV grade armoured cable for the following sizes including supply of NON FLP heavy duty Double Compresson cable glands, crimping type lugs and allied jointing materials, etc. all complete as per specification and direction of Engineer In-charge. Glands and lugs shall be of approved make. Copper lugs for copper cables and aluminium lugs for aluminium cables shall be used.
52vi) 3 Core x 1.5 sq. mm.
53vii) 3 Core x 2.5 sq. mm
54Dismantling roofing including ridges, hips valleys & gutters, False ceiling of any type and stacking the material within premises, of:
55i) G.S. Sheet/ Klippon galvalume sheet/ False ceiling panels
56BOHANA KISAN SEWA KENDRA (8X16 M)
57Providing and fixing 150F/200F flush panel,(pre-coated steel) False Ceiling made of Cold rolled steel sheet conforming to IS 513, having minimum yield stress and tensile stress as 240 Mpa and 300 Mpa respectively. Base metal thickness for ceiling panel and Carriers shall be 0.45mm and 0.55mm respectively. The steel surface shall have hot dip metallic coated with Zinc coating (galvanizing) as per IS277, with total mass of coating on both sides shall be 120 gms/sqm. The steel shall have organic coating with Regular Modified Polyester (RMP) paint on continues coil coating line. The thickness of coating on top side shall be 20-25 Microns (i.e. 15-18 microns RMP paint, over 5-7 microns epoxy primer) and back side 8-10 Microns RMP paint over epoxy primer. Total Coated Thickness (TCT) shall be 0.50 MM for Ceiling panel and 0.60 MM for Carrier. Sheet shall have protective Sheet shall have protective guard film of thickness of 25 microns minimum to avoid scratches while transportation and should be supplied in single length up to 6m (for panel) and up to 5m (for carrier) or as desired by Engineer-in-charge. The ceiling panel shall be clipped into carriers which are suspended from steel trusses/purlins with the help of GI suspension angle of size 25x25x0.5mm thick by means of rigid suspension system meant for exterior. The longitudinal joints of two panels shall be butt joined with a special type of panel splice to be fixed from inner side. The carrier will be joined with carrier splices maintaining a module of 150 mm. The spans shall not exceed as recommended and manufacturer recommendations shall be followed on installation procedure.
58Supply and fixing of Linear Recessed mounted LED (Light Emitting Diode) Light fittings of size 2400mm and 80 Watt, having IP 65 protection class with Pressure Die Cast Aluminium housing and with Polycarbonate diffuser of approved make or equivalent as per direction of Engineer-in-charge. High Efficiency Translucence(HET) diffuser. Colour Rendering Index CRI>80, Temp-0 to 45 Deg C, Driver efficiency>85%, THD < 10%, CCT- 6500 K Powerfactor>0.95, Surge protection-2 kV, Multistage Isolated Constant Current-Constant Voltage operated driver with range 140-270V AC and Safety Extra Low Voltage Safe level < 60V DC as per IEC standard, Luminaire lumen ≥ 2100lm. Each lot of Fittings shall have serial numbers & accompany LM79 / IS 16106 test reports and reference/batch nos of LEDs and fittings for verification at site. The supply of LED lighting shall be covered by a warranty of at least 72 months from the date of supply of the lighting and the LED light fitting shall be complete in all respects including LED, LED Driver, Electronic circuitory, Luminarie etc
59CABLING AND ALLIED WORKS - ARMOURED CABLES Supply & laying of XLPE insulated PVC sheathed aluminium/copper conductor, 1.1 kV grade armoured cable conforming to IS:7098, as per approved make in ground/ trench/surface/pipe, etc. whereever required as per direction of Engineer In-charge. Note: The rate of Installation should be inclusive of Cable clamps, tags Saddles, Consumables etc. Trays/pipes, trenches, fabricated tray supports etc will be covered & paid in Separate Items
60iii) 3 Core x 1.5 sq. mm. (copper)
61iv) 3 Core x 2.5 sq. mm Copper Cable FRLS
62CABLE TERMINATION GLANDS NON-FLP HEAVY DUTY DOUBLE COMPRESSION Cable Termination (NON FLP): Providing termination of 1.1 kV grade armoured cable for the following sizes including supply of NON FLP heavy duty Double Compresson cable glands, crimping type lugs and allied jointing materials, etc. all complete as per specification and direction of Engineer In-charge. Glands and lugs shall be of approved make. Copper lugs for copper cables and aluminium lugs for aluminium cables shall be used.
63vi) 3 Core x 1.5 sq. mm.
64vii) 3 Core x 2.5 sq. mm
65Dismantling roofing including ridges, hips valleys & gutters, False ceiling of any type and stacking the material within premises, of:
66i) G.S. Sheet/ Klippon galvalume sheet/ False ceiling panels
67SONOWAL & SONS POL - AGRO SERV (16X8 M)
68Providing and fixing 150F/200F flush panel,(pre-coated steel) False Ceiling made of Cold rolled steel sheet conforming to IS 513, having minimum yield stress and tensile stress as 240 Mpa and 300 Mpa respectively. Base metal thickness for ceiling panel and Carriers shall be 0.45mm and 0.55mm respectively. The steel surface shall have hot dip metallic coated with Zinc coating (galvanizing) as per IS277, with total mass of coating on both sides shall be 120 gms/sqm. The steel shall have organic coating with Regular Modified Polyester (RMP) paint on continues coil coating line. The thickness of coating on top side shall be 20-25 Microns (i.e. 15-18 microns RMP paint, over 5-7 microns epoxy primer) and back side 8-10 Microns RMP paint over epoxy primer. Total Coated Thickness (TCT) shall be 0.50 MM for Ceiling panel and 0.60 MM for Carrier. Sheet shall have protective Sheet shall have protective guard film of thickness of 25 microns minimum to avoid scratches while transportation and should be supplied in single length up to 6m (for panel) and up to 5m (for carrier) or as desired by Engineer-in-charge. The ceiling panel shall be clipped into carriers which are suspended from steel trusses/purlins with the help of GI suspension angle of size 25x25x0.5mm thick by means of rigid suspension system meant for exterior. The longitudinal joints of two panels shall be butt joined with a special type of panel splice to be fixed from inner side. The carrier will be joined with carrier splices maintaining a module of 150 mm. The spans shall not exceed as recommended and manufacturer recommendations shall be followed on installation procedure.
69Supply and fixing of Linear Recessed mounted LED (Light Emitting Diode) Light fittings of size 2400mm and 80 Watt, having IP 65 protection class with Pressure Die Cast Aluminium housing and with Polycarbonate diffuser of approved make or equivalent as per direction of Engineer-in-charge. High Efficiency Translucence(HET) diffuser. Colour Rendering Index CRI>80, Temp-0 to 45 Deg C, Driver efficiency>85%, THD < 10%, CCT- 6500 K Powerfactor>0.95, Surge protection-2 kV, Multistage Isolated Constant Current-Constant Voltage operated driver with range 140-270V AC and Safety Extra Low Voltage Safe level < 60V DC as per IEC standard, Luminaire lumen ≥ 2100lm. Each lot of Fittings shall have serial numbers & accompany LM79 / IS 16106 test reports and reference/batch nos of LEDs and fittings for verification at site. The supply of LED lighting shall be covered by a warranty of at least 72 months from the date of supply of the lighting and the LED light fitting shall be complete in all respects including LED, LED Driver, Electronic circuitory, Luminarie etc
70CABLING AND ALLIED WORKS - ARMOURED CABLES Supply & laying of XLPE insulated PVC sheathed aluminium/copper conductor, 1.1 kV grade armoured cable conforming to IS:7098, as per approved make in ground/ trench/surface/pipe, etc. whereever required as per direction of Engineer In-charge. Note: The rate of Installation should be inclusive of Cable clamps, tags Saddles, Consumables etc. Trays/pipes, trenches, fabricated tray supports etc will be covered & paid in Separate Items
71iii) 3 Core x 1.5 sq. mm. (copper)
72iv) 3 Core x 2.5 sq. mm Copper Cable FRLS
73CABLE TERMINATION GLANDS NON-FLP HEAVY DUTY DOUBLE COMPRESSION Cable Termination (NON FLP): Providing termination of 1.1 kV grade armoured cable for the following sizes including supply of NON FLP heavy duty Double Compresson cable glands, crimping type lugs and allied jointing materials, etc. all complete as per specification and direction of Engineer In-charge. Glands and lugs shall be of approved make. Copper lugs for copper cables and aluminium lugs for aluminium cables shall be used.
74vi) 3 Core x 1.5 sq. mm.
75vii) 3 Core x 2.5 sq. mm
76Dismantling roofing including ridges, hips valleys & gutters, False ceiling of any type and stacking the material within premises, of:
77i) G.S. Sheet/ Klippon galvalume sheet/ False ceiling panels
78NORTHERN HIGHWAY GAS STATION (12X16 M)
79Providing and fixing 150F/200F flush panel,(pre-coated steel) False Ceiling made of Cold rolled steel sheet conforming to IS 513, having minimum yield stress and tensile stress as 240 Mpa and 300 Mpa respectively. Base metal thickness for ceiling panel and Carriers shall be 0.45mm and 0.55mm respectively. The steel surface shall have hot dip metallic coated with Zinc coating (galvanizing) as per IS277, with total mass of coating on both sides shall be 120 gms/sqm. The steel shall have organic coating with Regular Modified Polyester (RMP) paint on continues coil coating line. The thickness of coating on top side shall be 20-25 Microns (i.e. 15-18 microns RMP paint, over 5-7 microns epoxy primer) and back side 8-10 Microns RMP paint over epoxy primer. Total Coated Thickness (TCT) shall be 0.50 MM for Ceiling panel and 0.60 MM for Carrier. Sheet shall have protective Sheet shall have protective guard film of thickness of 25 microns minimum to avoid scratches while transportation and should be supplied in single length up to 6m (for panel) and up to 5m (for carrier) or as desired by Engineer-in-charge. The ceiling panel shall be clipped into carriers which are suspended from steel trusses/purlins with the help of GI suspension angle of size 25x25x0.5mm thick by means of rigid suspension system meant for exterior. The longitudinal joints of two panels shall be butt joined with a special type of panel splice to be fixed from inner side. The carrier will be joined with carrier splices maintaining a module of 150 mm. The spans shall not exceed as recommended and manufacturer recommendations shall be followed on installation procedure.
80Supply and fixing of Linear Recessed mounted LED (Light Emitting Diode) Light fittings of size 2400mm and 80 Watt, having IP 65 protection class with Pressure Die Cast Aluminium housing and with Polycarbonate diffuser of approved make or equivalent as per direction of Engineer-in-charge. High Efficiency Translucence(HET) diffuser. Colour Rendering Index CRI>80, Temp-0 to 45 Deg C, Driver efficiency>85%, THD < 10%, CCT- 6500 K Powerfactor>0.95, Surge protection-2 kV, Multistage Isolated Constant Current-Constant Voltage operated driver with range 140-270V AC and Safety Extra Low Voltage Safe level < 60V DC as per IEC standard, Luminaire lumen ≥ 2100lm. Each lot of Fittings shall have serial numbers & accompany LM79 / IS 16106 test reports and reference/batch nos of LEDs and fittings for verification at site. The supply of LED lighting shall be covered by a warranty of at least 72 months from the date of supply of the lighting and the LED light fitting shall be complete in all respects including LED, LED Driver, Electronic circuitory, Luminarie etc
81CABLING AND ALLIED WORKS - ARMOURED CABLES Supply & laying of XLPE insulated PVC sheathed aluminium/copper conductor, 1.1 kV grade armoured cable conforming to IS:7098, as per approved make in ground/ trench/surface/pipe, etc. whereever required as per direction of Engineer In-charge. Note: The rate of Installation should be inclusive of Cable clamps, tags Saddles, Consumables etc. Trays/pipes, trenches, fabricated tray supports etc will be covered & paid in Separate Items
82iii) 3 Core x 1.5 sq. mm. (copper)
83iv) 3 Core x 2.5 sq. mm Copper Cable FRLS
84CABLE TERMINATION GLANDS NON-FLP HEAVY DUTY DOUBLE COMPRESSION Cable Termination (NON FLP): Providing termination of 1.1 kV grade armoured cable for the following sizes including supply of NON FLP heavy duty Double Compresson cable glands, crimping type lugs and allied jointing materials, etc. all complete as per specification and direction of Engineer In-charge. Glands and lugs shall be of approved make. Copper lugs for copper cables and aluminium lugs for aluminium cables shall be used.
85vi) 3 Core x 1.5 sq. mm.
86vii) 3 Core x 2.5 sq. mm
87Dismantling roofing including ridges, hips valleys & gutters, False ceiling of any type and stacking the material within premises, of:
88i) G.S. Sheet/ Klippon galvalume sheet/ False ceiling panels
89SKV ENTERPRISE (11X20 M)
90Providing and fixing 150F/200F flush panel,(pre-coated steel) False Ceiling made of Cold rolled steel sheet conforming to IS 513, having minimum yield stress and tensile stress as 240 Mpa and 300 Mpa respectively. Base metal thickness for ceiling panel and Carriers shall be 0.45mm and 0.55mm respectively. The steel surface shall have hot dip metallic coated with Zinc coating (galvanizing) as per IS277, with total mass of coating on both sides shall be 120 gms/sqm. The steel shall have organic coating with Regular Modified Polyester (RMP) paint on continues coil coating line. The thickness of coating on top side shall be 20-25 Microns (i.e. 15-18 microns RMP paint, over 5-7 microns epoxy primer) and back side 8-10 Microns RMP paint over epoxy primer. Total Coated Thickness (TCT) shall be 0.50 MM for Ceiling panel and 0.60 MM for Carrier. Sheet shall have protective Sheet shall have protective guard film of thickness of 25 microns minimum to avoid scratches while transportation and should be supplied in single length up to 6m (for panel) and up to 5m (for carrier) or as desired by Engineer-in-charge. The ceiling panel shall be clipped into carriers which are suspended from steel trusses/purlins with the help of GI suspension angle of size 25x25x0.5mm thick by means of rigid suspension system meant for exterior. The longitudinal joints of two panels shall be butt joined with a special type of panel splice to be fixed from inner side. The carrier will be joined with carrier splices maintaining a module of 150 mm. The spans shall not exceed as recommended and manufacturer recommendations shall be followed on installation procedure.
91Supply and fixing of Linear Recessed mounted LED (Light Emitting Diode) Light fittings of size 2400mm and 80 Watt, having IP 65 protection class with Pressure Die Cast Aluminium housing and with Polycarbonate diffuser of approved make or equivalent as per direction of Engineer-in-charge. High Efficiency Translucence(HET) diffuser. Colour Rendering Index CRI>80, Temp-0 to 45 Deg C, Driver efficiency>85%, THD < 10%, CCT- 6500 K Powerfactor>0.95, Surge protection-2 kV, Multistage Isolated Constant Current-Constant Voltage operated driver with range 140-270V AC and Safety Extra Low Voltage Safe level < 60V DC as per IEC standard, Luminaire lumen ≥ 2100lm. Each lot of Fittings shall have serial numbers & accompany LM79 / IS 16106 test reports and reference/batch nos of LEDs and fittings for verification at site. The supply of LED lighting shall be covered by a warranty of at least 72 months from the date of supply of the lighting and the LED light fitting shall be complete in all respects including LED, LED Driver, Electronic circuitory, Luminarie etc
92CABLING AND ALLIED WORKS - ARMOURED CABLES Supply & laying of XLPE insulated PVC sheathed aluminium/copper conductor, 1.1 kV grade armoured cable conforming to IS:7098, as per approved make in ground/ trench/surface/pipe, etc. whereever required as per direction of Engineer In-charge. Note: The rate of Installation should be inclusive of Cable clamps, tags Saddles, Consumables etc. Trays/pipes, trenches, fabricated tray supports etc will be covered & paid in Separate Items
93iii) 3 Core x 1.5 sq. mm. (copper)
94iv) 3 Core x 2.5 sq. mm Copper Cable FRLS
95CABLE TERMINATION GLANDS NON-FLP HEAVY DUTY DOUBLE COMPRESSION Cable Termination (NON FLP): Providing termination of 1.1 kV grade armoured cable for the following sizes including supply of NON FLP heavy duty Double Compresson cable glands, crimping type lugs and allied jointing materials, etc. all complete as per specification and direction of Engineer In-charge. Glands and lugs shall be of approved make. Copper lugs for copper cables and aluminium lugs for aluminium cables shall be used.
96vi) 3 Core x 1.5 sq. mm.
97vii) 3 Core x 2.5 sq. mm
98Dismantling roofing including ridges, hips valleys & gutters, False ceiling of any type and stacking the material within premises, of:
99i) G.S. Sheet/ Klippon galvalume sheet/ False ceiling panels
100MACHKHOWA KISAN SEVA KENDRA (16X8 M)
101Providing and fixing 150F/200F flush panel,(pre-coated steel) False Ceiling made of Cold rolled steel sheet conforming to IS 513, having minimum yield stress and tensile stress as 240 Mpa and 300 Mpa respectively. Base metal thickness for ceiling panel and Carriers shall be 0.45mm and 0.55mm respectively. The steel surface shall have hot dip metallic coated with Zinc coating (galvanizing) as per IS277, with total mass of coating on both sides shall be 120 gms/sqm. The steel shall have organic coating with Regular Modified Polyester (RMP) paint on continues coil coating line. The thickness of coating on top side shall be 20-25 Microns (i.e. 15-18 microns RMP paint, over 5-7 microns epoxy primer) and back side 8-10 Microns RMP paint over epoxy primer. Total Coated Thickness (TCT) shall be 0.50 MM for Ceiling panel and 0.60 MM for Carrier. Sheet shall have protective Sheet shall have protective guard film of thickness of 25 microns minimum to avoid scratches while transportation and should be supplied in single length up to 6m (for panel) and up to 5m (for carrier) or as desired by Engineer-in-charge. The ceiling panel shall be clipped into carriers which are suspended from steel trusses/purlins with the help of GI suspension angle of size 25x25x0.5mm thick by means of rigid suspension system meant for exterior. The longitudinal joints of two panels shall be butt joined with a special type of panel splice to be fixed from inner side. The carrier will be joined with carrier splices maintaining a module of 150 mm. The spans shall not exceed as recommended and manufacturer recommendations shall be followed on installation procedure.
102Supply and fixing of Linear Recessed mounted LED (Light Emitting Diode) Light fittings of size 2400mm and 80 Watt, having IP 65 protection class with Pressure Die Cast Aluminium housing and with Polycarbonate diffuser of approved make or equivalent as per direction of Engineer-in-charge. High Efficiency Translucence(HET) diffuser. Colour Rendering Index CRI>80, Temp-0 to 45 Deg C, Driver efficiency>85%, THD < 10%, CCT- 6500 K Powerfactor>0.95, Surge protection-2 kV, Multistage Isolated Constant Current-Constant Voltage operated driver with range 140-270V AC and Safety Extra Low Voltage Safe level < 60V DC as per IEC standard, Luminaire lumen ≥ 2100lm. Each lot of Fittings shall have serial numbers & accompany LM79 / IS 16106 test reports and reference/batch nos of LEDs and fittings for verification at site. The supply of LED lighting shall be covered by a warranty of at least 72 months from the date of supply of the lighting and the LED light fitting shall be complete in all respects including LED, LED Driver, Electronic circuitory, Luminarie etc
103CABLING AND ALLIED WORKS - ARMOURED CABLES Supply & laying of XLPE insulated PVC sheathed aluminium/copper conductor, 1.1 kV grade armoured cable conforming to IS:7098, as per approved make in ground/ trench/surface/pipe, etc. whereever required as per direction of Engineer In-charge. Note: The rate of Installation should be inclusive of Cable clamps, tags Saddles, Consumables etc. Trays/pipes, trenches, fabricated tray supports etc will be covered & paid in Separate Items
104iii) 3 Core x 1.5 sq. mm. (copper)
105iv) 3 Core x 2.5 sq. mm Copper Cable FRLS
106CABLE TERMINATION GLANDS NON-FLP HEAVY DUTY DOUBLE COMPRESSION Cable Termination (NON FLP): Providing termination of 1.1 kV grade armoured cable for the following sizes including supply of NON FLP heavy duty Double Compresson cable glands, crimping type lugs and allied jointing materials, etc. all complete as per specification and direction of Engineer In-charge. Glands and lugs shall be of approved make. Copper lugs for copper cables and aluminium lugs for aluminium cables shall be used.
107vi) 3 Core x 1.5 sq. mm.
108vii) 3 Core x 2.5 sq. mm
109Dismantling roofing including ridges, hips valleys & gutters, False ceiling of any type and stacking the material within premises, of:
110i) G.S. Sheet/ Klippon galvalume sheet/ False ceiling panels
111R.R & CO. PVT. LTD. (N. LAKHIMPUR) (14X8 M)
112Providing and fixing 150F/200F flush panel,(pre-coated steel) False Ceiling made of Cold rolled steel sheet conforming to IS 513, having minimum yield stress and tensile stress as 240 Mpa and 300 Mpa respectively. Base metal thickness for ceiling panel and Carriers shall be 0.45mm and 0.55mm respectively. The steel surface shall have hot dip metallic coated with Zinc coating (galvanizing) as per IS277, with total mass of coating on both sides shall be 120 gms/sqm. The steel shall have organic coating with Regular Modified Polyester (RMP) paint on continues coil coating line. The thickness of coating on top side shall be 20-25 Microns (i.e. 15-18 microns RMP paint, over 5-7 microns epoxy primer) and back side 8-10 Microns RMP paint over epoxy primer. Total Coated Thickness (TCT) shall be 0.50 MM for Ceiling panel and 0.60 MM for Carrier. Sheet shall have protective Sheet shall have protective guard film of thickness of 25 microns minimum to avoid scratches while transportation and should be supplied in single length up to 6m (for panel) and up to 5m (for carrier) or as desired by Engineer-in-charge. The ceiling panel shall be clipped into carriers which are suspended from steel trusses/purlins with the help of GI suspension angle of size 25x25x0.5mm thick by means of rigid suspension system meant for exterior. The longitudinal joints of two panels shall be butt joined with a special type of panel splice to be fixed from inner side. The carrier will be joined with carrier splices maintaining a module of 150 mm. The spans shall not exceed as recommended and manufacturer recommendations shall be followed on installation procedure.
113Supply and fixing of Linear Recessed mounted LED (Light Emitting Diode) Light fittings of size 2400mm and 80 Watt, having IP 65 protection class with Pressure Die Cast Aluminium housing and with Polycarbonate diffuser of approved make or equivalent as per direction of Engineer-in-charge. High Efficiency Translucence(HET) diffuser. Colour Rendering Index CRI>80, Temp-0 to 45 Deg C, Driver efficiency>85%, THD < 10%, CCT- 6500 K Powerfactor>0.95, Surge protection-2 kV, Multistage Isolated Constant Current-Constant Voltage operated driver with range 140-270V AC and Safety Extra Low Voltage Safe level < 60V DC as per IEC standard, Luminaire lumen ≥ 2100lm. Each lot of Fittings shall have serial numbers & accompany LM79 / IS 16106 test reports and reference/batch nos of LEDs and fittings for verification at site. The supply of LED lighting shall be covered by a warranty of at least 72 months from the date of supply of the lighting and the LED light fitting shall be complete in all respects including LED, LED Driver, Electronic circuitory, Luminarie etc
114CABLING AND ALLIED WORKS - ARMOURED CABLES Supply & laying of XLPE insulated PVC sheathed aluminium/copper conductor, 1.1 kV grade armoured cable conforming to IS:7098, as per approved make in ground/ trench/surface/pipe, etc. whereever required as per direction of Engineer In-charge. Note: The rate of Installation should be inclusive of Cable clamps, tags Saddles, Consumables etc. Trays/pipes, trenches, fabricated tray supports etc will be covered & paid in Separate Items
115iii) 3 Core x 1.5 sq. mm. (copper)
116iv) 3 Core x 2.5 sq. mm Copper Cable FRLS
117CABLE TERMINATION GLANDS NON-FLP HEAVY DUTY DOUBLE COMPRESSION Cable Termination (NON FLP): Providing termination of 1.1 kV grade armoured cable for the following sizes including supply of NON FLP heavy duty Double Compresson cable glands, crimping type lugs and allied jointing materials, etc. all complete as per specification and direction of Engineer In-charge. Glands and lugs shall be of approved make. Copper lugs for copper cables and aluminium lugs for aluminium cables shall be used.
118vi) 3 Core x 1.5 sq. mm.
119vii) 3 Core x 2.5 sq. mm
120Dismantling roofing including ridges, hips valleys & gutters, False ceiling of any type and stacking the material within premises, of:
121i) G.S. Sheet/ Klippon galvalume sheet/ False ceiling panels
122Mebo Automobiles (Adhoc) (12X19 M)
123Providing and fixing 150F/200F flush panel,(pre-coated steel) False Ceiling made of Cold rolled steel sheet conforming to IS 513, having minimum yield stress and tensile stress as 240 Mpa and 300 Mpa respectively. Base metal thickness for ceiling panel and Carriers shall be 0.45mm and 0.55mm respectively. The steel surface shall have hot dip metallic coated with Zinc coating (galvanizing) as per IS277, with total mass of coating on both sides shall be 120 gms/sqm. The steel shall have organic coating with Regular Modified Polyester (RMP) paint on continues coil coating line. The thickness of coating on top side shall be 20-25 Microns (i.e. 15-18 microns RMP paint, over 5-7 microns epoxy primer) and back side 8-10 Microns RMP paint over epoxy primer. Total Coated Thickness (TCT) shall be 0.50 MM for Ceiling panel and 0.60 MM for Carrier. Sheet shall have protective Sheet shall have protective guard film of thickness of 25 microns minimum to avoid scratches while transportation and should be supplied in single length up to 6m (for panel) and up to 5m (for carrier) or as desired by Engineer-in-charge. The ceiling panel shall be clipped into carriers which are suspended from steel trusses/purlins with the help of GI suspension angle of size 25x25x0.5mm thick by means of rigid suspension system meant for exterior. The longitudinal joints of two panels shall be butt joined with a special type of panel splice to be fixed from inner side. The carrier will be joined with carrier splices maintaining a module of 150 mm. The spans shall not exceed as recommended and manufacturer recommendations shall be followed on installation procedure.
124Supply and fixing of Linear Recessed mounted LED (Light Emitting Diode) Light fittings of size 2400mm and 80 Watt, having IP 65 protection class with Pressure Die Cast Aluminium housing and with Polycarbonate diffuser of approved make or equivalent as per direction of Engineer-in-charge. High Efficiency Translucence(HET) diffuser. Colour Rendering Index CRI>80, Temp-0 to 45 Deg C, Driver efficiency>85%, THD < 10%, CCT- 6500 K Powerfactor>0.95, Surge protection-2 kV, Multistage Isolated Constant Current-Constant Voltage operated driver with range 140-270V AC and Safety Extra Low Voltage Safe level < 60V DC as per IEC standard, Luminaire lumen ≥ 2100lm. Each lot of Fittings shall have serial numbers & accompany LM79 / IS 16106 test reports and reference/batch nos of LEDs and fittings for verification at site. The supply of LED lighting shall be covered by a warranty of at least 72 months from the date of supply of the lighting and the LED light fitting shall be complete in all respects including LED, LED Driver, Electronic circuitory, Luminarie etc
125CABLING AND ALLIED WORKS - ARMOURED CABLES Supply & laying of XLPE insulated PVC sheathed aluminium/copper conductor, 1.1 kV grade armoured cable conforming to IS:7098, as per approved make in ground/ trench/surface/pipe, etc. whereever required as per direction of Engineer In-charge. Note: The rate of Installation should be inclusive of Cable clamps, tags Saddles, Consumables etc. Trays/pipes, trenches, fabricated tray supports etc will be covered & paid in Separate Items
126iii) 3 Core x 1.5 sq. mm. (copper)
127iv) 3 Core x 2.5 sq. mm Copper Cable FRLS
128CABLE TERMINATION GLANDS NON-FLP HEAVY DUTY DOUBLE COMPRESSION Cable Termination (NON FLP): Providing termination of 1.1 kV grade armoured cable for the following sizes including supply of NON FLP heavy duty Double Compresson cable glands, crimping type lugs and allied jointing materials, etc. all complete as per specification and direction of Engineer In-charge. Glands and lugs shall be of approved make. Copper lugs for copper cables and aluminium lugs for aluminium cables shall be used.
129vi) 3 Core x 1.5 sq. mm.
130vii) 3 Core x 2.5 sq. mm
131Dismantling roofing including ridges, hips valleys & gutters, False ceiling of any type and stacking the material within premises, of:
132i) G.S. Sheet/ Klippon galvalume sheet/ False ceiling panels
133PATCHUP FILLING STATION (15X8 M)
134Providing and fixing 150F/200F flush panel,(pre-coated steel) False Ceiling made of Cold rolled steel sheet conforming to IS 513, having minimum yield stress and tensile stress as 240 Mpa and 300 Mpa respectively. Base metal thickness for ceiling panel and Carriers shall be 0.45mm and 0.55mm respectively. The steel surface shall have hot dip metallic coated with Zinc coating (galvanizing) as per IS277, with total mass of coating on both sides shall be 120 gms/sqm. The steel shall have organic coating with Regular Modified Polyester (RMP) paint on continues coil coating line. The thickness of coating on top side shall be 20-25 Microns (i.e. 15-18 microns RMP paint, over 5-7 microns epoxy primer) and back side 8-10 Microns RMP paint over epoxy primer. Total Coated Thickness (TCT) shall be 0.50 MM for Ceiling panel and 0.60 MM for Carrier. Sheet shall have protective Sheet shall have protective guard film of thickness of 25 microns minimum to avoid scratches while transportation and should be supplied in single length up to 6m (for panel) and up to 5m (for carrier) or as desired by Engineer-in-charge. The ceiling panel shall be clipped into carriers which are suspended from steel trusses/purlins with the help of GI suspension angle of size 25x25x0.5mm thick by means of rigid suspension system meant for exterior. The longitudinal joints of two panels shall be butt joined with a special type of panel splice to be fixed from inner side. The carrier will be joined with carrier splices maintaining a module of 150 mm. The spans shall not exceed as recommended and manufacturer recommendations shall be followed on installation procedure.
135Supply and fixing of Linear Recessed mounted LED (Light Emitting Diode) Light fittings of size 2400mm and 80 Watt, having IP 65 protection class with Pressure Die Cast Aluminium housing and with Polycarbonate diffuser of approved make or equivalent as per direction of Engineer-in-charge. High Efficiency Translucence(HET) diffuser. Colour Rendering Index CRI>80, Temp-0 to 45 Deg C, Driver efficiency>85%, THD < 10%, CCT- 6500 K Powerfactor>0.95, Surge protection-2 kV, Multistage Isolated Constant Current-Constant Voltage operated driver with range 140-270V AC and Safety Extra Low Voltage Safe level < 60V DC as per IEC standard, Luminaire lumen ≥ 2100lm. Each lot of Fittings shall have serial numbers & accompany LM79 / IS 16106 test reports and reference/batch nos of LEDs and fittings for verification at site. The supply of LED lighting shall be covered by a warranty of at least 72 months from the date of supply of the lighting and the LED light fitting shall be complete in all respects including LED, LED Driver, Electronic circuitory, Luminarie etc
136CABLING AND ALLIED WORKS - ARMOURED CABLES Supply & laying of XLPE insulated PVC sheathed aluminium/copper conductor, 1.1 kV grade armoured cable conforming to IS:7098, as per approved make in ground/ trench/surface/pipe, etc. whereever required as per direction of Engineer In-charge. Note: The rate of Installation should be inclusive of Cable clamps, tags Saddles, Consumables etc. Trays/pipes, trenches, fabricated tray supports etc will be covered & paid in Separate Items
137iii) 3 Core x 1.5 sq. mm. (copper)
138iv) 3 Core x 2.5 sq. mm Copper Cable FRLS
139CABLE TERMINATION GLANDS NON-FLP HEAVY DUTY DOUBLE COMPRESSION Cable Termination (NON FLP): Providing termination of 1.1 kV grade armoured cable for the following sizes including supply of NON FLP heavy duty Double Compresson cable glands, crimping type lugs and allied jointing materials, etc. all complete as per specification and direction of Engineer In-charge. Glands and lugs shall be of approved make. Copper lugs for copper cables and aluminium lugs for aluminium cables shall be used.
140vi) 3 Core x 1.5 sq. mm.
141vii) 3 Core x 2.5 sq. mm
142Dismantling roofing including ridges, hips valleys & gutters, False ceiling of any type and stacking the material within premises, of:
143i) G.S. Sheet/ Klippon galvalume sheet/ False ceiling panels
144PASIGHAT SERVICE STATION (16X8 M)
145Providing and fixing 150F/200F flush panel,(pre-coated steel) False Ceiling made of Cold rolled steel sheet conforming to IS 513, having minimum yield stress and tensile stress as 240 Mpa and 300 Mpa respectively. Base metal thickness for ceiling panel and Carriers shall be 0.45mm and 0.55mm respectively. The steel surface shall have hot dip metallic coated with Zinc coating (galvanizing) as per IS277, with total mass of coating on both sides shall be 120 gms/sqm. The steel shall have organic coating with Regular Modified Polyester (RMP) paint on continues coil coating line. The thickness of coating on top side shall be 20-25 Microns (i.e. 15-18 microns RMP paint, over 5-7 microns epoxy primer) and back side 8-10 Microns RMP paint over epoxy primer. Total Coated Thickness (TCT) shall be 0.50 MM for Ceiling panel and 0.60 MM for Carrier. Sheet shall have protective Sheet shall have protective guard film of thickness of 25 microns minimum to avoid scratches while transportation and should be supplied in single length up to 6m (for panel) and up to 5m (for carrier) or as desired by Engineer-in-charge. The ceiling panel shall be clipped into carriers which are suspended from steel trusses/purlins with the help of GI suspension angle of size 25x25x0.5mm thick by means of rigid suspension system meant for exterior. The longitudinal joints of two panels shall be butt joined with a special type of panel splice to be fixed from inner side. The carrier will be joined with carrier splices maintaining a module of 150 mm. The spans shall not exceed as recommended and manufacturer recommendations shall be followed on installation procedure.
146Supply and fixing of Linear Recessed mounted LED (Light Emitting Diode) Light fittings of size 2400mm and 80 Watt, having IP 65 protection class with Pressure Die Cast Aluminium housing and with Polycarbonate diffuser of approved make or equivalent as per direction of Engineer-in-charge. High Efficiency Translucence(HET) diffuser. Colour Rendering Index CRI>80, Temp-0 to 45 Deg C, Driver efficiency>85%, THD < 10%, CCT- 6500 K Powerfactor>0.95, Surge protection-2 kV, Multistage Isolated Constant Current-Constant Voltage operated driver with range 140-270V AC and Safety Extra Low Voltage Safe level < 60V DC as per IEC standard, Luminaire lumen ≥ 2100lm. Each lot of Fittings shall have serial numbers & accompany LM79 / IS 16106 test reports and reference/batch nos of LEDs and fittings for verification at site. The supply of LED lighting shall be covered by a warranty of at least 72 months from the date of supply of the lighting and the LED light fitting shall be complete in all respects including LED, LED Driver, Electronic circuitory, Luminarie etc
147CABLING AND ALLIED WORKS - ARMOURED CABLES Supply & laying of XLPE insulated PVC sheathed aluminium/copper conductor, 1.1 kV grade armoured cable conforming to IS:7098, as per approved make in ground/ trench/surface/pipe, etc. whereever required as per direction of Engineer In-charge. Note: The rate of Installation should be inclusive of Cable clamps, tags Saddles, Consumables etc. Trays/pipes, trenches, fabricated tray supports etc will be covered & paid in Separate Items
148iii) 3 Core x 1.5 sq. mm. (copper)
149iv) 3 Core x 2.5 sq. mm Copper Cable FRLS
150CABLE TERMINATION GLANDS NON-FLP HEAVY DUTY DOUBLE COMPRESSION Cable Termination (NON FLP): Providing termination of 1.1 kV grade armoured cable for the following sizes including supply of NON FLP heavy duty Double Compresson cable glands, crimping type lugs and allied jointing materials, etc. all complete as per specification and direction of Engineer In-charge. Glands and lugs shall be of approved make. Copper lugs for copper cables and aluminium lugs for aluminium cables shall be used.
151vi) 3 Core x 1.5 sq. mm.
152vii) 3 Core x 2.5 sq. mm
153Dismantling roofing including ridges, hips valleys & gutters, False ceiling of any type and stacking the material within premises, of:
154i) G.S. Sheet/ Klippon galvalume sheet/ False ceiling panels
155WANGNAO FUEL STATION (11X14 M)
156Providing and fixing 150F/200F flush panel,(pre-coated steel) False Ceiling made of Cold rolled steel sheet conforming to IS 513, having minimum yield stress and tensile stress as 240 Mpa and 300 Mpa respectively. Base metal thickness for ceiling panel and Carriers shall be 0.45mm and 0.55mm respectively. The steel surface shall have hot dip metallic coated with Zinc coating (galvanizing) as per IS277, with total mass of coating on both sides shall be 120 gms/sqm. The steel shall have organic coating with Regular Modified Polyester (RMP) paint on continues coil coating line. The thickness of coating on top side shall be 20-25 Microns (i.e. 15-18 microns RMP paint, over 5-7 microns epoxy primer) and back side 8-10 Microns RMP paint over epoxy primer. Total Coated Thickness (TCT) shall be 0.50 MM for Ceiling panel and 0.60 MM for Carrier. Sheet shall have protective Sheet shall have protective guard film of thickness of 25 microns minimum to avoid scratches while transportation and should be supplied in single length up to 6m (for panel) and up to 5m (for carrier) or as desired by Engineer-in-charge. The ceiling panel shall be clipped into carriers which are suspended from steel trusses/purlins with the help of GI suspension angle of size 25x25x0.5mm thick by means of rigid suspension system meant for exterior. The longitudinal joints of two panels shall be butt joined with a special type of panel splice to be fixed from inner side. The carrier will be joined with carrier splices maintaining a module of 150 mm. The spans shall not exceed as recommended and manufacturer recommendations shall be followed on installation procedure.
157Supply and fixing of Linear Recessed mounted LED (Light Emitting Diode) Light fittings of size 2400mm and 80 Watt, having IP 65 protection class with Pressure Die Cast Aluminium housing and with Polycarbonate diffuser of approved make or equivalent as per direction of Engineer-in-charge. High Efficiency Translucence(HET) diffuser. Colour Rendering Index CRI>80, Temp-0 to 45 Deg C, Driver efficiency>85%, THD < 10%, CCT- 6500 K Powerfactor>0.95, Surge protection-2 kV, Multistage Isolated Constant Current-Constant Voltage operated driver with range 140-270V AC and Safety Extra Low Voltage Safe level < 60V DC as per IEC standard, Luminaire lumen ≥ 2100lm. Each lot of Fittings shall have serial numbers & accompany LM79 / IS 16106 test reports and reference/batch nos of LEDs and fittings for verification at site. The supply of LED lighting shall be covered by a warranty of at least 72 months from the date of supply of the lighting and the LED light fitting shall be complete in all respects including LED, LED Driver, Electronic circuitory, Luminarie etc
158CABLING AND ALLIED WORKS - ARMOURED CABLES Supply & laying of XLPE insulated PVC sheathed aluminium/copper conductor, 1.1 kV grade armoured cable conforming to IS:7098, as per approved make in ground/ trench/surface/pipe, etc. whereever required as per direction of Engineer In-charge. Note: The rate of Installation should be inclusive of Cable clamps, tags Saddles, Consumables etc. Trays/pipes, trenches, fabricated tray supports etc will be covered & paid in Separate Items
159iii) 3 Core x 1.5 sq. mm. (copper)
160iv) 3 Core x 2.5 sq. mm Copper Cable FRLS
161CABLE TERMINATION GLANDS NON-FLP HEAVY DUTY DOUBLE COMPRESSION Cable Termination (NON FLP): Providing termination of 1.1 kV grade armoured cable for the following sizes including supply of NON FLP heavy duty Double Compresson cable glands, crimping type lugs and allied jointing materials, etc. all complete as per specification and direction of Engineer In-charge. Glands and lugs shall be of approved make. Copper lugs for copper cables and aluminium lugs for aluminium cables shall be used.
162vi) 3 Core x 1.5 sq. mm.
163vii) 3 Core x 2.5 sq. mm
164Dismantling roofing including ridges, hips valleys & gutters, False ceiling of any type and stacking the material within premises, of:
165i) G.S. Sheet/ Klippon galvalume sheet/ False ceiling panels
166LEINAK PUMP AGENCY (16X8 M)
167Providing and fixing 150F/200F flush panel,(pre-coated steel) False Ceiling made of Cold rolled steel sheet conforming to IS 513, having minimum yield stress and tensile stress as 240 Mpa and 300 Mpa respectively. Base metal thickness for ceiling panel and Carriers shall be 0.45mm and 0.55mm respectively. The steel surface shall have hot dip metallic coated with Zinc coating (galvanizing) as per IS277, with total mass of coating on both sides shall be 120 gms/sqm. The steel shall have organic coating with Regular Modified Polyester (RMP) paint on continues coil coating line. The thickness of coating on top side shall be 20-25 Microns (i.e. 15-18 microns RMP paint, over 5-7 microns epoxy primer) and back side 8-10 Microns RMP paint over epoxy primer. Total Coated Thickness (TCT) shall be 0.50 MM for Ceiling panel and 0.60 MM for Carrier. Sheet shall have protective Sheet shall have protective guard film of thickness of 25 microns minimum to avoid scratches while transportation and should be supplied in single length up to 6m (for panel) and up to 5m (for carrier) or as desired by Engineer-in-charge. The ceiling panel shall be clipped into carriers which are suspended from steel trusses/purlins with the help of GI suspension angle of size 25x25x0.5mm thick by means of rigid suspension system meant for exterior. The longitudinal joints of two panels shall be butt joined with a special type of panel splice to be fixed from inner side. The carrier will be joined with carrier splices maintaining a module of 150 mm. The spans shall not exceed as recommended and manufacturer recommendations shall be followed on installation procedure.
168Supply and fixing of Linear Recessed mounted LED (Light Emitting Diode) Light fittings of size 2400mm and 80 Watt, having IP 65 protection class with Pressure Die Cast Aluminium housing and with Polycarbonate diffuser of approved make or equivalent as per direction of Engineer-in-charge. High Efficiency Translucence(HET) diffuser. Colour Rendering Index CRI>80, Temp-0 to 45 Deg C, Driver efficiency>85%, THD < 10%, CCT- 6500 K Powerfactor>0.95, Surge protection-2 kV, Multistage Isolated Constant Current-Constant Voltage operated driver with range 140-270V AC and Safety Extra Low Voltage Safe level < 60V DC as per IEC standard, Luminaire lumen ≥ 2100lm. Each lot of Fittings shall have serial numbers & accompany LM79 / IS 16106 test reports and reference/batch nos of LEDs and fittings for verification at site. The supply of LED lighting shall be covered by a warranty of at least 72 months from the date of supply of the lighting and the LED light fitting shall be complete in all respects including LED, LED Driver, Electronic circuitory, Luminarie etc
169CABLING AND ALLIED WORKS - ARMOURED CABLES Supply & laying of XLPE insulated PVC sheathed aluminium/copper conductor, 1.1 kV grade armoured cable conforming to IS:7098, as per approved make in ground/ trench/surface/pipe, etc. whereever required as per direction of Engineer In-charge. Note: The rate of Installation should be inclusive of Cable clamps, tags Saddles, Consumables etc. Trays/pipes, trenches, fabricated tray supports etc will be covered & paid in Separate Items
170iii) 3 Core x 1.5 sq. mm. (copper)
171iv) 3 Core x 2.5 sq. mm Copper Cable FRLS
172CABLE TERMINATION GLANDS NON-FLP HEAVY DUTY DOUBLE COMPRESSION Cable Termination (NON FLP): Providing termination of 1.1 kV grade armoured cable for the following sizes including supply of NON FLP heavy duty Double Compresson cable glands, crimping type lugs and allied jointing materials, etc. all complete as per specification and direction of Engineer In-charge. Glands and lugs shall be of approved make. Copper lugs for copper cables and aluminium lugs for aluminium cables shall be used.
173vi) 3 Core x 1.5 sq. mm.
174vii) 3 Core x 2.5 sq. mm
175Dismantling roofing including ridges, hips valleys & gutters, False ceiling of any type and stacking the material within premises, of:
176i) G.S. Sheet/ Klippon galvalume sheet/ False ceiling panels
177SALIGRAM BRIDHICHAND & CO.- HANSARA (18X8 M)
178Providing and fixing 150F/200F flush panel,(pre-coated steel) False Ceiling made of Cold rolled steel sheet conforming to IS 513, having minimum yield stress and tensile stress as 240 Mpa and 300 Mpa respectively. Base metal thickness for ceiling panel and Carriers shall be 0.45mm and 0.55mm respectively. The steel surface shall have hot dip metallic coated with Zinc coating (galvanizing) as per IS277, with total mass of coating on both sides shall be 120 gms/sqm. The steel shall have organic coating with Regular Modified Polyester (RMP) paint on continues coil coating line. The thickness of coating on top side shall be 20-25 Microns (i.e. 15-18 microns RMP paint, over 5-7 microns epoxy primer) and back side 8-10 Microns RMP paint over epoxy primer. Total Coated Thickness (TCT) shall be 0.50 MM for Ceiling panel and 0.60 MM for Carrier. Sheet shall have protective Sheet shall have protective guard film of thickness of 25 microns minimum to avoid scratches while transportation and should be supplied in single length up to 6m (for panel) and up to 5m (for carrier) or as desired by Engineer-in-charge. The ceiling panel shall be clipped into carriers which are suspended from steel trusses/purlins with the help of GI suspension angle of size 25x25x0.5mm thick by means of rigid suspension system meant for exterior. The longitudinal joints of two panels shall be butt joined with a special type of panel splice to be fixed from inner side. The carrier will be joined with carrier splices maintaining a module of 150 mm. The spans shall not exceed as recommended and manufacturer recommendations shall be followed on installation procedure.
179Supply and fixing of Linear Recessed mounted LED (Light Emitting Diode) Light fittings of size 2400mm and 80 Watt, having IP 65 protection class with Pressure Die Cast Aluminium housing and with Polycarbonate diffuser of approved make or equivalent as per direction of Engineer-in-charge. High Efficiency Translucence(HET) diffuser. Colour Rendering Index CRI>80, Temp-0 to 45 Deg C, Driver efficiency>85%, THD < 10%, CCT- 6500 K Powerfactor>0.95, Surge protection-2 kV, Multistage Isolated Constant Current-Constant Voltage operated driver with range 140-270V AC and Safety Extra Low Voltage Safe level < 60V DC as per IEC standard, Luminaire lumen ≥ 2100lm. Each lot of Fittings shall have serial numbers & accompany LM79 / IS 16106 test reports and reference/batch nos of LEDs and fittings for verification at site. The supply of LED lighting shall be covered by a warranty of at least 72 months from the date of supply of the lighting and the LED light fitting shall be complete in all respects including LED, LED Driver, Electronic circuitory, Luminarie etc
180CABLING AND ALLIED WORKS - ARMOURED CABLES Supply & laying of XLPE insulated PVC sheathed aluminium/copper conductor, 1.1 kV grade armoured cable conforming to IS:7098, as per approved make in ground/ trench/surface/pipe, etc. whereever required as per direction of Engineer In-charge. Note: The rate of Installation should be inclusive of Cable clamps, tags Saddles, Consumables etc. Trays/pipes, trenches, fabricated tray supports etc will be covered & paid in Separate Items
181iii) 3 Core x 1.5 sq. mm. (copper)
182iv) 3 Core x 2.5 sq. mm Copper Cable FRLS
183CABLE TERMINATION GLANDS NON-FLP HEAVY DUTY DOUBLE COMPRESSION Cable Termination (NON FLP): Providing termination of 1.1 kV grade armoured cable for the following sizes including supply of NON FLP heavy duty Double Compresson cable glands, crimping type lugs and allied jointing materials, etc. all complete as per specification and direction of Engineer In-charge. Glands and lugs shall be of approved make. Copper lugs for copper cables and aluminium lugs for aluminium cables shall be used.
184vi) 3 Core x 1.5 sq. mm.
185vii) 3 Core x 2.5 sq. mm
186Dismantling roofing including ridges, hips valleys & gutters, False ceiling of any type and stacking the material within premises, of:
187i) G.S. Sheet/ Klippon galvalume sheet/ False ceiling panels
188WAKRO SERVICE STATION (17X8 M)
189Providing and fixing 150F/200F flush panel,(pre-coated steel) False Ceiling made of Cold rolled steel sheet conforming to IS 513, having minimum yield stress and tensile stress as 240 Mpa and 300 Mpa respectively. Base metal thickness for ceiling panel and Carriers shall be 0.45mm and 0.55mm respectively. The steel surface shall have hot dip metallic coated with Zinc coating (galvanizing) as per IS277, with total mass of coating on both sides shall be 120 gms/sqm. The steel shall have organic coating with Regular Modified Polyester (RMP) paint on continues coil coating line. The thickness of coating on top side shall be 20-25 Microns (i.e. 15-18 microns RMP paint, over 5-7 microns epoxy primer) and back side 8-10 Microns RMP paint over epoxy primer. Total Coated Thickness (TCT) shall be 0.50 MM for Ceiling panel and 0.60 MM for Carrier. Sheet shall have protective Sheet shall have protective guard film of thickness of 25 microns minimum to avoid scratches while transportation and should be supplied in single length up to 6m (for panel) and up to 5m (for carrier) or as desired by Engineer-in-charge. The ceiling panel shall be clipped into carriers which are suspended from steel trusses/purlins with the help of GI suspension angle of size 25x25x0.5mm thick by means of rigid suspension system meant for exterior. The longitudinal joints of two panels shall be butt joined with a special type of panel splice to be fixed from inner side. The carrier will be joined with carrier splices maintaining a module of 150 mm. The spans shall not exceed as recommended and manufacturer recommendations shall be followed on installation procedure.
190Supply and fixing of Linear Recessed mounted LED (Light Emitting Diode) Light fittings of size 2400mm and 80 Watt, having IP 65 protection class with Pressure Die Cast Aluminium housing and with Polycarbonate diffuser of approved make or equivalent as per direction of Engineer-in-charge. High Efficiency Translucence(HET) diffuser. Colour Rendering Index CRI>80, Temp-0 to 45 Deg C, Driver efficiency>85%, THD < 10%, CCT- 6500 K Powerfactor>0.95, Surge protection-2 kV, Multistage Isolated Constant Current-Constant Voltage operated driver with range 140-270V AC and Safety Extra Low Voltage Safe level < 60V DC as per IEC standard, Luminaire lumen ≥ 2100lm. Each lot of Fittings shall have serial numbers & accompany LM79 / IS 16106 test reports and reference/batch nos of LEDs and fittings for verification at site. The supply of LED lighting shall be covered by a warranty of at least 72 months from the date of supply of the lighting and the LED light fitting shall be complete in all respects including LED, LED Driver, Electronic circuitory, Luminarie etc
191CABLING AND ALLIED WORKS - ARMOURED CABLES Supply & laying of XLPE insulated PVC sheathed aluminium/copper conductor, 1.1 kV grade armoured cable conforming to IS:7098, as per approved make in ground/ trench/surface/pipe, etc. whereever required as per direction of Engineer In-charge. Note: The rate of Installation should be inclusive of Cable clamps, tags Saddles, Consumables etc. Trays/pipes, trenches, fabricated tray supports etc will be covered & paid in Separate Items
192iii) 3 Core x 1.5 sq. mm. (copper)
193iv) 3 Core x 2.5 sq. mm Copper Cable FRLS
194CABLE TERMINATION GLANDS NON-FLP HEAVY DUTY DOUBLE COMPRESSION Cable Termination (NON FLP): Providing termination of 1.1 kV grade armoured cable for the following sizes including supply of NON FLP heavy duty Double Compresson cable glands, crimping type lugs and allied jointing materials, etc. all complete as per specification and direction of Engineer In-charge. Glands and lugs shall be of approved make. Copper lugs for copper cables and aluminium lugs for aluminium cables shall be used.
195vi) 3 Core x 1.5 sq. mm.
196vii) 3 Core x 2.5 sq. mm
197Dismantling roofing including ridges, hips valleys & gutters, False ceiling of any type and stacking the material within premises, of:
198i) G.S. Sheet/ Klippon galvalume sheet/ False ceiling panels
199UNIVERSAL AGENCIES(BADULIPAR) (17 x 8)
200Providing and fixing 150F/200F flush panel,(pre-coated steel) False Ceiling made of Cold rolled steel sheet conforming to IS 513, having minimum yield stress and tensile stress as 240 Mpa and 300 Mpa respectively. Base metal thickness for ceiling panel and Carriers shall be 0.45mm and 0.55mm respectively. The steel surface shall have hot dip metallic coated with Zinc coating (galvanizing) as per IS277, with total mass of coating on both sides shall be 120 gms/sqm. The steel shall have organic coating with Regular Modified Polyester (RMP) paint on continues coil coating line. The thickness of coating on top side shall be 20-25 Microns (i.e. 15-18 microns RMP paint, over 5-7 microns epoxy primer) and back side 8-10 Microns RMP paint over epoxy primer. Total Coated Thickness (TCT) shall be 0.50 MM for Ceiling panel and 0.60 MM for Carrier. Sheet shall have protective Sheet shall have protective guard film of thickness of 25 microns minimum to avoid scratches while transportation and should be supplied in single length up to 6m (for panel) and up to 5m (for carrier) or as desired by Engineer-in-charge. The ceiling panel shall be clipped into carriers which are suspended from steel trusses/purlins with the help of GI suspension angle of size 25x25x0.5mm thick by means of rigid suspension system meant for exterior. The longitudinal joints of two panels shall be butt joined with a special type of panel splice to be fixed from inner side. The carrier will be joined with carrier splices maintaining a module of 150 mm. The spans shall not exceed as recommended and manufacturer recommendations shall be followed on installation procedure.
201Supply and fixing of Linear Recessed mounted LED (Light Emitting Diode) Light fittings of size 2400mm and 80 Watt, having IP 65 protection class with Pressure Die Cast Aluminium housing and with Polycarbonate diffuser of approved make or equivalent as per direction of Engineer-in-charge. High Efficiency Translucence(HET) diffuser. Colour Rendering Index CRI>80, Temp-0 to 45 Deg C, Driver efficiency>85%, THD < 10%, CCT- 6500 K Powerfactor>0.95, Surge protection-2 kV, Multistage Isolated Constant Current-Constant Voltage operated driver with range 140-270V AC and Safety Extra Low Voltage Safe level < 60V DC as per IEC standard, Luminaire lumen ≥ 2100lm. Each lot of Fittings shall have serial numbers & accompany LM79 / IS 16106 test reports and reference/batch nos of LEDs and fittings for verification at site. The supply of LED lighting shall be covered by a warranty of at least 72 months from the date of supply of the lighting and the LED light fitting shall be complete in all respects including LED, LED Driver, Electronic circuitory, Luminarie etc
202CABLING AND ALLIED WORKS - ARMOURED CABLES Supply & laying of XLPE insulated PVC sheathed aluminium/copper conductor, 1.1 kV grade armoured cable conforming to IS:7098, as per approved make in ground/ trench/surface/pipe, etc. whereever required as per direction of Engineer In-charge. Note: The rate of Installation should be inclusive of Cable clamps, tags Saddles, Consumables etc. Trays/pipes, trenches, fabricated tray supports etc will be covered & paid in Separate Items
203iii) 3 Core x 1.5 sq. mm. (copper)
204iv) 3 Core x 2.5 sq. mm Copper Cable FRLS
205CABLE TERMINATION GLANDS NON-FLP HEAVY DUTY DOUBLE COMPRESSION Cable Termination (NON FLP): Providing termination of 1.1 kV grade armoured cable for the following sizes including supply of NON FLP heavy duty Double Compresson cable glands, crimping type lugs and allied jointing materials, etc. all complete as per specification and direction of Engineer In-charge. Glands and lugs shall be of approved make. Copper lugs for copper cables and aluminium lugs for aluminium cables shall be used.
206vi) 3 Core x 1.5 sq. mm.
207vii) 3 Core x 2.5 sq. mm
208Dismantling roofing including ridges, hips valleys & gutters, False ceiling of any type and stacking the material within premises, of:
209i) G.S. Sheet/ Klippon galvalume sheet/ False ceiling panels
210MAA SERVICE STATION (12 x 17)
211Providing and fixing 150F/200F flush panel,(pre-coated steel) False Ceiling made of Cold rolled steel sheet conforming to IS 513, having minimum yield stress and tensile stress as 240 Mpa and 300 Mpa respectively. Base metal thickness for ceiling panel and Carriers shall be 0.45mm and 0.55mm respectively. The steel surface shall have hot dip metallic coated with Zinc coating (galvanizing) as per IS277, with total mass of coating on both sides shall be 120 gms/sqm. The steel shall have organic coating with Regular Modified Polyester (RMP) paint on continues coil coating line. The thickness of coating on top side shall be 20-25 Microns (i.e. 15-18 microns RMP paint, over 5-7 microns epoxy primer) and back side 8-10 Microns RMP paint over epoxy primer. Total Coated Thickness (TCT) shall be 0.50 MM for Ceiling panel and 0.60 MM for Carrier. Sheet shall have protective Sheet shall have protective guard film of thickness of 25 microns minimum to avoid scratches while transportation and should be supplied in single length up to 6m (for panel) and up to 5m (for carrier) or as desired by Engineer-in-charge. The ceiling panel shall be clipped into carriers which are suspended from steel trusses/purlins with the help of GI suspension angle of size 25x25x0.5mm thick by means of rigid suspension system meant for exterior. The longitudinal joints of two panels shall be butt joined with a special type of panel splice to be fixed from inner side. The carrier will be joined with carrier splices maintaining a module of 150 mm. The spans shall not exceed as recommended and manufacturer recommendations shall be followed on installation procedure.
212Supply and fixing of Linear Recessed mounted LED (Light Emitting Diode) Light fittings of size 2400mm and 80 Watt, having IP 65 protection class with Pressure Die Cast Aluminium housing and with Polycarbonate diffuser of approved make or equivalent as per direction of Engineer-in-charge. High Efficiency Translucence(HET) diffuser. Colour Rendering Index CRI>80, Temp-0 to 45 Deg C, Driver efficiency>85%, THD < 10%, CCT- 6500 K Powerfactor>0.95, Surge protection-2 kV, Multistage Isolated Constant Current-Constant Voltage operated driver with range 140-270V AC and Safety Extra Low Voltage Safe level < 60V DC as per IEC standard, Luminaire lumen ≥ 2100lm. Each lot of Fittings shall have serial numbers & accompany LM79 / IS 16106 test reports and reference/batch nos of LEDs and fittings for verification at site. The supply of LED lighting shall be covered by a warranty of at least 72 months from the date of supply of the lighting and the LED light fitting shall be complete in all respects including LED, LED Driver, Electronic circuitory, Luminarie etc
213CABLING AND ALLIED WORKS - ARMOURED CABLES Supply & laying of XLPE insulated PVC sheathed aluminium/copper conductor, 1.1 kV grade armoured cable conforming to IS:7098, as per approved make in ground/ trench/surface/pipe, etc. whereever required as per direction of Engineer In-charge. Note: The rate of Installation should be inclusive of Cable clamps, tags Saddles, Consumables etc. Trays/pipes, trenches, fabricated tray supports etc will be covered & paid in Separate Items
214iii) 3 Core x 1.5 sq. mm. (copper)
215iv) 3 Core x 2.5 sq. mm Copper Cable FRLS
216CABLE TERMINATION GLANDS NON-FLP HEAVY DUTY DOUBLE COMPRESSION Cable Termination (NON FLP): Providing termination of 1.1 kV grade armoured cable for the following sizes including supply of NON FLP heavy duty Double Compresson cable glands, crimping type lugs and allied jointing materials, etc. all complete as per specification and direction of Engineer In-charge. Glands and lugs shall be of approved make. Copper lugs for copper cables and aluminium lugs for aluminium cables shall be used.
217vi) 3 Core x 1.5 sq. mm.
218vii) 3 Core x 2.5 sq. mm
219Dismantling roofing including ridges, hips valleys & gutters, False ceiling of any type and stacking the material within premises, of:
220i) G.S. Sheet/ Klippon galvalume sheet/ False ceiling panels
221G. B. FILLING STATION (8 x17)
222Providing and fixing 150F/200F flush panel,(pre-coated steel) False Ceiling made of Cold rolled steel sheet conforming to IS 513, having minimum yield stress and tensile stress as 240 Mpa and 300 Mpa respectively. Base metal thickness for ceiling panel and Carriers shall be 0.45mm and 0.55mm respectively. The steel surface shall have hot dip metallic coated with Zinc coating (galvanizing) as per IS277, with total mass of coating on both sides shall be 120 gms/sqm. The steel shall have organic coating with Regular Modified Polyester (RMP) paint on continues coil coating line. The thickness of coating on top side shall be 20-25 Microns (i.e. 15-18 microns RMP paint, over 5-7 microns epoxy primer) and back side 8-10 Microns RMP paint over epoxy primer. Total Coated Thickness (TCT) shall be 0.50 MM for Ceiling panel and 0.60 MM for Carrier. Sheet shall have protective Sheet shall have protective guard film of thickness of 25 microns minimum to avoid scratches while transportation and should be supplied in single length up to 6m (for panel) and up to 5m (for carrier) or as desired by Engineer-in-charge. The ceiling panel shall be clipped into carriers which are suspended from steel trusses/purlins with the help of GI suspension angle of size 25x25x0.5mm thick by means of rigid suspension system meant for exterior. The longitudinal joints of two panels shall be butt joined with a special type of panel splice to be fixed from inner side. The carrier will be joined with carrier splices maintaining a module of 150 mm. The spans shall not exceed as recommended and manufacturer recommendations shall be followed on installation procedure.
223Supply and fixing of Linear Recessed mounted LED (Light Emitting Diode) Light fittings of size 2400mm and 80 Watt, having IP 65 protection class with Pressure Die Cast Aluminium housing and with Polycarbonate diffuser of approved make or equivalent as per direction of Engineer-in-charge. High Efficiency Translucence(HET) diffuser. Colour Rendering Index CRI>80, Temp-0 to 45 Deg C, Driver efficiency>85%, THD < 10%, CCT- 6500 K Powerfactor>0.95, Surge protection-2 kV, Multistage Isolated Constant Current-Constant Voltage operated driver with range 140-270V AC and Safety Extra Low Voltage Safe level < 60V DC as per IEC standard, Luminaire lumen ≥ 2100lm. Each lot of Fittings shall have serial numbers & accompany LM79 / IS 16106 test reports and reference/batch nos of LEDs and fittings for verification at site. The supply of LED lighting shall be covered by a warranty of at least 72 months from the date of supply of the lighting and the LED light fitting shall be complete in all respects including LED, LED Driver, Electronic circuitory, Luminarie etc
224CABLING AND ALLIED WORKS - ARMOURED CABLES Supply & laying of XLPE insulated PVC sheathed aluminium/copper conductor, 1.1 kV grade armoured cable conforming to IS:7098, as per approved make in ground/ trench/surface/pipe, etc. whereever required as per direction of Engineer In-charge. Note: The rate of Installation should be inclusive of Cable clamps, tags Saddles, Consumables etc. Trays/pipes, trenches, fabricated tray supports etc will be covered & paid in Separate Items
225iii) 3 Core x 1.5 sq. mm. (copper)
226iv) 3 Core x 2.5 sq. mm Copper Cable FRLS
227CABLE TERMINATION GLANDS NON-FLP HEAVY DUTY DOUBLE COMPRESSION Cable Termination (NON FLP): Providing termination of 1.1 kV grade armoured cable for the following sizes including supply of NON FLP heavy duty Double Compresson cable glands, crimping type lugs and allied jointing materials, etc. all complete as per specification and direction of Engineer In-charge. Glands and lugs shall be of approved make. Copper lugs for copper cables and aluminium lugs for aluminium cables shall be used.
228vi) 3 Core x 1.5 sq. mm.
229vii) 3 Core x 2.5 sq. mm
230Dismantling roofing including ridges, hips valleys & gutters, False ceiling of any type and stacking the material within premises, of:
231i) G.S. Sheet/ Klippon galvalume sheet/ False ceiling panels Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 58054993
AUTHORITY Boards / Undertakings / PSU
TENDER VALUE Ref. Documents
LAST DATE 22-10-2026
Authority
Authority Name Indian Oil Corporation Limited
Work Description Tender for Provision Of Linear Led Lights Including Replacement Of Existing False Ceiling And Allied Works For A Site Retail Outlets Of Tinsukia Divisional Office Under Indianoil Aod State Office.Lot 1 Ros:20. Hill Service Station (8X16 M)30. Ladulal Jain & Sons(Numaligarh) (17X21 M)40. Ladulal Jain & Sons(Silonijan) (12X29 M)50. Noklak Filling Station (12X8 M)60. Bohana Kisan Sewa Kendra (8X16 M)70. Sonowal & Sons Pol - Agro Serv (16X8 M)80. Northern Highway Gas Station (12X16 M)90. Skv Enterprise (11X20 M)120. Mebo Automobiles (Adhoc) (12X19 M)130. Patchup Filling Station (15X8 M)160. Leinak Pump Agency (16X8 M)190. Universal Agencies(Badulipar) (17X7)210. G. B. Filling Station (8X17)Lot 2 Ros:10. Nirada Fuel Service Station (12X27 M)100. Machkhowa Kisan Seva Kendra (16X8 M)110. repair renovation & Co. Pvt. Ltd. (N. Lakhimpur) (14X8 M)140. Pasighat Service Station (16X8 M)150. Wangnao Fuel Station (11X14 M)170. Saligram Bridhichand & Co.- Hansara (18X8 M)180. Wakro Service Station (17X8 M)200. Maa Service Station (12X17)
Basic Detail
Tender No ER-MnC/2026-27/LT/360
Bidding Type Tender
Location
City Tinsukia
State Assam
Key Dates
Publish Date 15 Oct 2026
Submission Date 22 Oct 2026
Open Date 23 Oct 2026
Finance
Tender Value Ref. Documents
Tender Fee Ref. Documents
EMD Ref. Documents
Exemption Not Available
Document List
a7715fc1-43db-4bb9-8f0b-71fc2fe7f99e.html
Bidders_help_Document_for_1.pdf
BOQ_202105.xls
DRAWINGS-I.rar
DRAWINGS-II.rar
DRAWINGS-III.rar
FAQs-IOCL-Online-EMD.pdf
GCC_HOSOR2021_PPE_ISB_SAF_2.rar
Part-B_Version-2.pdf
PR_LINEAR_LED_LIGHTS.pdf
Special_Instructions_to_t_3.pdf
TECHBIDLT360.pdf
Technicalspecification__L_4.rar
Tender-Acceptance-Format.pdf
Tendernotice_1.pdf
Undertakings_and_Declarat_5.xls

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Oct 15, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Oct 22, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 1 day
Oct 23, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 2 days

Tender Documents

Download All (ZIP) ↓
html

a7715fc1-43db-4bb9-8f0b-71fc2fe7f99e.html

pdf

Bidders_help_Document_for_1.pdf

xls

BOQ_202105.xls

rar

DRAWINGS-I.rar

rar

DRAWINGS-II.rar

rar

DRAWINGS-III.rar

pdf

FAQs-IOCL-Online-EMD.pdf

rar

GCC_HOSOR2021_PPE_ISB_SAF_2.rar

pdf

Part-B_Version-2.pdf

pdf

PR_LINEAR_LED_LIGHTS.pdf

pdf

Special_Instructions_to_t_3.pdf

pdf

TECHBIDLT360.pdf

rar

Technicalspecification__L_4.rar

pdf

Tender-Acceptance-Format.pdf

pdf

Tendernotice_1.pdf

xls

Undertakings_and_Declarat_5.xls

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender