Tender For Construction Of Godabarish Mishra Adarsh Prathamik Vidyalaya At Ughs Kongra, Jharigam Block, Chaklapadar(Gp), Nabarangpur District (Phase-Ii)
Tender Value
11.53 Crore
Estimated cost
Bid Submission
29 Oct 2026
2 days left
EMD
21.53 Lakhs
Bank guarantee accepted
Document Fee
23600
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Nabarangpur → Odisha
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Construction Of Godabarish Mishra Adarsh Prathamik Vidyalaya At Ughs Kongra, Jharigam Block, Chaklapadar(Gp), Nabarangpur District (Phase-Ii)
BOQ
| Sl. No. | Item Description |
| 1 | ABSTRACT SL.NO. Name Of Work Amount |
| 2 | Construction of GMAPV at Govt. UGHS Ichhapur, Ichhapur GP, Jharigram Block, Nabarangpur, Odisha |
| 3 | Construction of GMAPV at UGHS Kongra, Chakla Padar GP, Jharigram Block, Nabarangpur, Odisha Total 97724808.0 GST 18 % 17590465.439999998 Grand Total 115315274.0 BOQ ABSTRACT Name of the work- Construction Of Godabarish Mishra Adarsh Prathamik Vidyalaya At UGHS Kongra, Jharigam Block, Chaklapadar(GP), Nabarangpur District (Phase-II) Sl.No Description Amount |
| 4 | All Civil Work (Civil Work+Solar+Fire+Landscaping) |
| 5 | P.H. & Sanitary Work |
| 6 | Electrical Work TOTAL 48862404.0 48862404.0 8795232.719999999 8795232.719999999 57657637.0 57657637.0 115315274.0 Name of the work- Construction Of Godabarish Mishra Adarsh Prathamik Vidyalaya At UGHS Kongra, Jharigam Block, Chaklapadar(GP), Nabarangpur District (Phase-II) BILL OF QUANTITIES (CIVIL WORK) Sl.No. Description of items GROUND FLOOR TERRACE C.WALL & FENCING APP ROAD FENCING RainWater Harvesting Paver -Road Quantity Unit Rate (Rs,) Amount (Rs.) DISMANTLING WORKS Removing white or colour wash by scrapping and sand papering and preparing the surface smooth including necessary repairs to scratches etc.complete 0.0 0.0 (a) Ground Floor 0.0 Sqm 10.5 0.0 (b) First Floor 0.0 Sqm 10.5 0.0 Dismantling brick or stone masonry in lime or cement mortar above 3m. height including stacking the useful materials for reuse and removing the debris within 50m. Lead 0.0 0.0 (a) Ground Floor 0.0 Cum 1743.4812720848058 0.0 (b) First Floor 0.0 Cum 1830.7 0.0 Removing old lime or cement plaster from walls including raking out joints 12 mm deep and removing the debris within 50m lead 0.0 0.0 (a) Ground Floor 0.0 Sqm 58.9537 0.0 (b) First Floor 0.0 Sqm 61.9 0.0 (c) Second Floor 0.0 Sqm 65.0 0.0 Dismantling and removing old tiled flooring including removing the base coarse and stacking the useful materials for reuse and removing the debris within 50m lead 0.0 0.0 (a) Ground Floor 0.0 Sqm 147.3691 0.0 (b) First Floor 0.0 Sqm 154.7 0.0 Dismantling and removing old tiled cladding from walls including racking out joints 12mm deep stacking the useful materials for reuse and removing the debris within 50m lead 0.0 0.0 (a) Ground Floor 0.0 Sqm 76.63879999999999 0.0 (b) First Floor 0.0 Sqm 80.5 0.0 Dismantling and removing doors, windows and ventilators including removal of frame, hinges, fastening and stacking the same for reuse and removing the debris within 50m lead 0.0 0.0 (a) Ground Floor 0.0 Sqm 465.1353 0.0 (b) First Floor 0.0 Sqm 488.4 0.0 Dismantling and removing cement concrete including stacking the useful materials for reuse and removing the debris within 50m lead 0.0 0.0 (a) Ground Floor 0.0 Cum 877.1648 0.0 (b) First Floor 0.0 Cum 921.0 0.0 Dismantling and removing R.C.C. columns beams slab staircase landing, lintels including stacking the useful materials for reuse and removing the debris within 50m lead. 0.0 0.0 (a) Ground Floor 0.0 Cum 1731.81 0.0 (b) First Floor 0.0 Cum 1818.4 0.0 Dismantling G.C.I. or A.C. sheet roofing after carefully removing the bolts and nuts including stacking of the materials for reuse and removing the debris within 50m lead 0.0 0.0 (a) Terace Floor 0.0 Sqm 106.28 0.0 Dismantling wrought and framed timber in roof frame work of floors after careful removal of nail, bolts etc. and stacking of the materials for reuse and removing the debris within 50m lead 0.0 0.0 (a) Terace Floor 0.0 cum 1478.9531 0.0 Dismantling and removing 2.5 cm thick grading concrete from roof slab cleaning the surface lowering and removing the debris within 50m lead 0.0 0.0 (a) Ground Floor 0.0 Sqm 132.6332 0.0 (b) First Floor 0.0 Sqm 139.3 0.0 (a) Terace Floor 0.0 Sqm 146.2 0.0 Disposal of moorum/building rubbish/ malba/ similar unserviceable, dismantled or waste material by mechanical transport including loading, transporting, unloading to approved municipal dumping ground for lead upto 10 km for all lifts, complete as per directions of Engineer-in-charge. 0.0 0.0 (a) Ground Floor 0.0 Cum 330.8 0.0 (b) First Floor 0.0 Cum 330.8 0.0 (c) Second Floor 0.0 Cum 330.8 0.0 0.0 0.0 0.0 0.0 0.0 0.0 Cutting of trees, including cutting of trunks, branches and removal of stumps, roots, stacking of serviceable material with all lifts and up to a lead of 1000 metres and earth filling in the depression/pit. 0.0 0.0 Girth from 300mm to 600mm 0.0 Each 385.0 0.0 SUB-STRUCTURE CIVIL WORK 0.0 Clearing and grubbing roads and land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300 mm, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, up to a lead of 1000 metres including removal and disposal of top organic soil not exceeding 150 mm in thickness. 10.58 10.58 Sqm 8.63 91.3054 EARTH WORK |
| 7 | Excavation, loading, unloading and carriage by mechanical means of all kinds of soil, including stoney earth, gravel and moorum etc interspread with boulders upto 1/2 cum size with all lifts and delifts including trimming of slopes and bed to design section and depositing the the excavated materials away from work site as per the specification and as directed by the Engineer- in-charge within an initial lead of 1km from the place of excavation complete. 1732.49 142.2 32.24 50.0 1891.63 Cum 146.7 277502.121 20860.739999999998 0.0 254156.283 Earth work in excavation in foundation trenches, column foundation, pit, etc in all kind of soil including moorum stony earth and earth mixed with boulders except sheet rock and boulders not requiring blasting including dressing of sides and levelling the bed up to the required depth and depositing the excavated materials away from the work site with initial lead of 50 mtr and all lifts, including shoring, shuttering & dewatering (if required) with cost of labour, labour cess, hire & running charges of all machineries, sundries & T&P required for the work complete as directed by the Engineer in charge. 0.0 0.0 0.0 0.0 0.0 Upto 1.5mtr Depth 0.0 Cum 282.9 0.0 0.0 0.0 0.0 From 1.5mtr Depth to 3.0mtr Depth 0.0 Cum 305.36 0.0 0.0 0.0 0.0 |
| 8 | Filling the Plinth with excavated materials (excluding rock), in layers not exceeding 0.225 m in depth including cost of watering, ramming, dressing and levelling the top to proper level & gradient, cost of labour, conveyance, loading, unloading, T&P, etc, all complete as per the direction of Engineer-in-Charge. 1154.99 94.8 1249.79 Cum 157.2 196466.98799999998 14902.559999999998 0.0 181564.42799999999 |
| 9 | Filling the Foundation, Sides of Foundation, etc. in mechanical means with excavated materials (excluding rock), in layers not exceeding 0.225 m in depth including cost of watering, ramming, dressing and levelling the top to proper level & gradient, cost of machinary, conveyance, loading, unloading, T&P, etc, all complete as per the direction of Engineer-in-Charge. 0.0 0.0 Cum 146.7 0.0 0.0 0.0 0.0 Disposal of surplus/ excavated materials by mechanical means within 5km. Lead away from the site including cost of all labour , T&P complete as per the direction of the Engineer-in-charge. 0.0 0.0 0.0 0.0 0.0 (a)Ground Floor 0.0 Cum 278.8 0.0 0.0 0.0 0.0 |
| 10 | Supplying, diluting and preparing chemical emulsion like Imidacloprid 30.5 % SC or other chemicals approved by Central Insecticides Board or as directed by the manufacturer and spraying the mixture uniformly by sprayer as Pre/Post-Constructional Anti-termite Treatment confirming to IS 6313 (Part-II) including the cost of all materials, cost of all labour, conveyance, loading, unloading, T&P, etc. all complete as per the direction of Engineer-in-Charge. 1818.06 1818.06 sqm 104.5 189987.27 0.0 0.0 189987.27 |
| 11 | Supplying and Filling with Sand in Foundation and Plinth in layers not exceeding 20 cm in depth, well watered and compact , top surface dressed and levelled to proper level and gradient including cost of all materials , conveyance, royalties, loading, unloading, cost of all labour, T&P, etc.All compelete as per the dirrection of Engineer-in-charge. 1045.4785000000002 11.79 3.18 30.0 1090.4485000000002 Cum 817.6 891550.6936000002 9639.503999999999 0.0 854783.2216000002 |
| 12 | Providing and lying Plain Cement Concrete of proportion (1:3:6) in foundation & floor using 40 mm & down grade black hard crusher broken granite stone metal, washed and screened sharp sand of approved quality from approved quarry including hoisting, lowering, laying the concrete, ramming, watering and curing etc. complete to required thickness including cost of all materials, conveyance, loading, unloading, royalties, cost of labours, T&P, hire & running charges of concrete mixer, etc. all complete as per the direction of the Engineer -in -charge. 327.74 11.79 339.53000000000003 Cum 6220.7 2112114.271 73342.05299999999 0.0 2038772.218 Depth 1.5 to 4.5mtr lvl 0.0 Cum 6559.4 0.0 0.0 0.0 0.0 |
| 13 | Providing and lying Plain Cement Concrete of proportion (1:4:8) in foundation & floor using 40 mm & down grade black hard crusher broken granite stone metal, washed and screened sharp sand of approved quality from approved quarry including hoisting, lowering, laying the concrete, ramming, watering and curing etc. complete to required thickness including cost of all materials, conveyance, loading, unloading, royalties, taxes, cost of labours, T&P, hire & running charges of concrete mixer, etc. all complete as per the direction of the Engineer -in -charge. Ground Floor 30.0 30.0 Cum 5826.3 174789.0 0.0 0.0 0.0 Depth 1.5 to 4.5mtr lvl 1.28 1.28 Cum 6164.9 7891.072 0.0 0.0 0.0 |
| 14 | Providing and laying in position of plain cement concrete 1:2:4 (1 Cement :2 Sand :4 Coarse Agreegate) in floors using 12mm size hard broken crusher broken granite stone metal, washed and screened sharp sand of approved quality from approved quarry including hoisting, lowering, laying the concrete, ramming, watering and curing etc. complete to required thickness including cost of all materials, conveyance, loading, unloading, royalties, cost of labours, T&P, hire & running charges of concrete mixer, etc. all complete as per the direction of the Engineer -in -charge. Ground Floor 13.089374999999999 13.089374999999999 Cum 7841.5 102640.33406249998 0.0 0.0 102640.33406249998 RCC WORK 0.0 0.0 0.0 0.0 Providing, lifting, hoisting and laying in position machine batched , machine mixed and machine vibrated design mix cement concrete of M-25(minimum cement content not less than 403 Kg/Cum) grade in reinforced cement concrete structural elements using black hard crusher broken granite chips of approved quality from approved quarry including mixing and compacting to proper shape and size, level and plumbs and finishing the exposed surfaces smooth including the cost of all materials, cost of labour, conveyance,loading, unloading, royalties, watering and curing for the required period, T&P , hire & running charges of concrete mixer and vibrator, cost of Admixtures in recommended proportions ( as per IS 9103 ) to accelerate, retard setting of concrete, improve workability without impairing strength and durability etc. complete as per the direction of the Engineer-in-charge but excluding the cost of steel reinforcement & centring shuttering. 0.0 0.0 0.0 0.0 0.0 Ground Floor 0.0 Cum 6685.3 0.0 0.0 0.0 0.0 First Floor 0.0 Cum 6810.1 0.0 0.0 0.0 0.0 |
| 15 | Providing, lifting, hoisting and laying in position machine batched , machine mixed and machine vibrated design mix cement concrete of M-25 Including the cost of Centering and Shuttering (minimum cement content not less than 403 Kg/Cum) grade in reinforced cement concrete structural elements using black hard crusher broken granite chips of approved quality from approved quarry including mixing and compacting to proper shape and size, level and plumbs and finishing the exposed surfaces smooth including the cost of all materials, cost of labour, conveyance,loading, unloading, royalties, watering and curing for the required period, T&P , hire & running charges of concrete mixer and vibrator, cost of Admixtures in recommended proportions ( as per IS 9103 ) to accelerate, retard setting of concrete, improve workability without impairing strength and durability etc. complete as per the direction of the Engineer-in-charge but excluding the cost of steel reinforcement. (A)R.C.C. foundation and footing bases of columns mass concrete pre-cast slab etc. 0.0 0.0 0.0 0.0 (a)Ground Floor 355.45 12.0 367.45 Cum 7060.1 2594233.745 84721.20000000001 0.0 2509512.545 (B)R.C.C. Column uto plinth 0.0 0.0 0.0 0.0 Ground Floor 28.03 1.91 29.94 Cum 16442.9 492300.42600000004 31405.939000000002 0.0 460894.4870000001 |
| 16 | Providing & fixing TOR Fe-500 HYSD Reinforcement bars of required diameter and approved quality for Reinforced Cement Concrete work including straightening, cutting, bending, binding, welding(if approved) , joining (if necessary), tying the grills, hoisting, lowering and placing in position as per the approved design & drawings (BBS) with provision of standard fan hooks including the cost of all materials, cost of all labour, conveyance, loading, unloading, cost of binding wires of 18 to 20 gauge, T&P, etc, all complete as per the direction of Engineer-in-Charge.Note: (Linear measurements will be taken & quantity will be calculated on standard weight. Lap length of bars & Weight of binding wire will not be considered for measurement and payment). 0.0 0.0 0.0 GROUND FLOOR SUB STRUCTURE 334.81 13.04 347.85 Qntl 9294.3 3233022.255 121197.67199999998 0.0 3111824.5829999996 0.0 0.0 0.0 MASSONARY WORKS 0.0 0.0 0.0 0.0 |
| 17 | Providing and laying Brick Masonry work in Foundation & Plinth using Fly ash bricks of 25 Cm. x 12 Cm. x 8 Cm. size having crushing strength not less than 75 Kg./Cm2 with dimensional tolerance + 2 % confirming to IS 12894 and IS 2212 in cement mortar (1:6) affter immersing the bricks for minimum 6 hours in water before use, with all necessary projections, splays cutting, circular moulding, corbelling, etc. as per the drawings including the cost of all materials, cost of all labour, conveyance, royalties, loading, unloading, scaffolding, staging, watering and curing, sundries, T&P, etc. complete as per the direction of the Engineer-in-charge. (a)Ground Floor 125.31 13.27 13.22 151.8 Cum 5815.7 882823.26 77174.33899999999 0.0 728765.367 0.0 0.0 0.0 |
| 18 | Supplying and fixing of 80mm thick cement concrete interlocking paver block of M-40 grade of approved make, design, colour and size made by Block making machine with proper compaction laid in required pattern etc. complete in all respect conforming to IRC SP - 63:2018. |
| 19 | Supplying and fixing of Pre cast kerb stone of size 300mm x 300mm x 150mm of M-30 grade of approved make, design, colour and size made by Block making machine with proper compaction fixed in required pattern etc. complete in all respect conforming to IS 5758:1984. |
| 20 | Painting two coats of synthetic enamel paint on road work over Plaster or RCC Works like (kerb wall,bridge rcc barrier) as per approved shade of approved quality , sand papering, polishing the surface including cost, conveyance,labour, T&P, scaffolding etc. as required for the work complete as per direction of Engineer-in-charge. (The paints are to be approved before procurement and use) KERB PAINTING 48.6 48.6 Sqm 84.5 4106.7 0.0 0.0 0.0 0.0 0.0 0.0 TOTAL 11339883.601062499 0.0 0.0 0.0 0.0 0.0 0.0 SUPER-STRUCTURE 0.0 0.0 0.0 RCC WORK 0.0 0.0 0.0 |
| 21 | Providing, lifting, hoisting and laying in position machine batched , machine mixed and machine vibrated design mix cement concrete of M-25 Including the cost of Centering and Shuttering (minimum cement content not less than 403 Kg/Cum) grade in reinforced cement concrete structural elements using black hard crusher broken granite chips of approved quality from approved quarry including mixing and compacting to proper shape and size, level and plumbs and finishing the exposed surfaces smooth including the cost of all materials, cost of labour, conveyance,loading, unloading, royalties, watering and curing for the required period, T&P , hire & running charges of concrete mixer and vibrator, cost of Admixtures in recommended proportions ( as per IS 9103 ) to accelerate, retard setting of concrete, improve workability without impairing strength and durability etc. complete as per the direction of the Engineer-in-charge but excluding the cost of steel reinforcement. a R.C.C. Plinth Beam 0.0 0.0 0.0 0.0 (a)Ground Floor 102.43 6.68 1.0 110.11000000000001 Cum 7934.5 873667.7950000002 53002.46 0.0 812730.8350000001 b (B)R.C.C. Column & Roof Beam 0.0 0.0 0.0 0.0 Ground Floor 192.67000000000002 1.75 194.42000000000002 Cum 16442.9 3196828.6180000007 28775.075000000004 0.0 3168053.5430000005 Terrace 12.91 12.91 Cum 18519.2 239082.872 0.0 239082.872 0.0 Second Floor 0.0 Cum 21004.6 0.0 0.0 0.0 0.0 Third Floor 0.0 Cum 23979.8 0.0 0.0 0.0 0.0 Fourth Floor 0.0 Cum 27541.8 0.0 0.0 0.0 0.0 Fifth Floor 0.0 Cum 31806.8 0.0 0.0 0.0 0.0 SiXth Floor 0.0 Cum 36913.8 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 c (C) R.C.C. Slab & RCC Chajja 0.0 0.0 0.0 0.0 Ground Floor 269.96999999999997 0.44 270.40999999999997 Cum 12838.9 3471766.9489999996 5649.116 0.0 3466117.8329999996 Terrace 19.290000000000003 19.290000000000003 Cum 14194.4 273809.976 0.0 273809.976 0.0 Second Floor 0.0 Cum 15814.9 0.0 0.0 0.0 0.0 Third Floor 0.0 Cum 17752.2 0.0 0.0 0.0 0.0 Fourth Floor 0.0 Cum 20068.7 0.0 0.0 0.0 0.0 Fifth Floor 0.0 Cum 22839.0 0.0 0.0 0.0 0.0 SiXth Floor 0.0 Cum 26152.5 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 d (D)R.C.C. Staircase 0.0 0.0 0.0 0.0 Ground Floor 9.78 9.78 Cum 16305.1 159463.878 0.0 0.0 159463.878 Terrace 0.0 Cum 18353.9 0.0 0.0 0.0 0.0 Second Floor 0.0 Cum 20806.2 0.0 0.0 0.0 0.0 Third Floor 0.0 Cum 23741.8 0.0 0.0 0.0 0.0 Fourth Floor 0.0 Cum 27256.3 0.0 0.0 0.0 0.0 Fifth Floor 0.0 Cum 31464.1 0.0 0.0 0.0 0.0 SiXth Floor 0.0 Cum 36502.6 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 e (E)R.C.C. lintel 0.0 0.0 0.0 0.0 Ground Floor 34.64 34.64 Cum 14773.8 511764.432 0.0 0.0 511764.432 Terrace 0.58 0.58 Cum 16516.4 9579.512 0.0 9579.512 0.0 Second Floor 0.0 Cum 18601.2 0.0 0.0 0.0 0.0 Third Floor 0.0 Cum 21095.9 0.0 0.0 0.0 0.0 Fourth Floor 0.0 Cum 24081.2 0.0 0.0 0.0 0.0 Fifth Floor 0.0 Cum 27654.1 0.0 0.0 0.0 0.0 SiXth Floor 0.0 Cum 31930.5 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 f (F)R.C.C. Fins 0.0 0.0 0.0 0.0 Ground Floor 1.66 1.66 Cum 12123.1 20124.346 0.0 0.0 20124.346 First Floor 0.0 Cum 13335.5 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 R.C.C. Grade Slab 0.0 0.0 0.0 0.0 0.0 Ground Floor 0.0 Cum 7060.1 0.0 0.0 0.0 0.0 Double under reamed pile foundation with R.C.C. M25 using 12mm size black hard granite (crusher broken)stone chips including cost of boreholes but excluding cost of M.S. rod/Tor steel and labour chrages for cutting, bending and binding of steel. 0.0 0.0 0.0 0.0 0.0 450mm Dia & 6.00Mtr Long Per One Pile 0.0 Nos 16667.33 0.0 0.0 0.0 0.0 For Each Addl. Depth of 0.50Mtr Beyond Initial Depth of 6.0Mtr add Extra to Rate 0.0 Nos 793.57 0.0 0.0 0.0 0.0 |
| 22 | Providing and lying plain cement concrete of proportion (1:6:12) in false column with 40 mm. Size black hard crusher broken granite stone metal and screened and washed sharp sand for mortar of approved quality from approved quarry, washed and cleaned including hoisting, lowering, laying concrete, ramming, watering and curing etc. complete to required levels laid in layers not exceeding 15 cm thick in each layer including cost, conveyance, loading, unloading, royalties and taxes all materials and cost all labours, sundries, T & P required for the work including shoring, shuttering and dewatering if required including hire & running charges of water pump complete as per the instruction of the Engineer-in-Charge. |
| 23 | Providing & fixing TOR Fe-500 HYSD Reinforcement bars of required diameter and approved quality for Reinforced Cement Concrete work including straightening, cutting, bending, binding, welding(if approved) , joining (if necessary), tying the grills, hoisting, lowering and placing in position as per the approved design & drawings (BBS) with provision of standard fan hooks including the cost of all materials, cost of all labour, conveyance, loading, unloading, cost of binding wires of 18 to 20 gauge, T&P, etc, all complete as per the direction of Engineer-in-Charge.Note: (Linear measurements will be taken & quantity will be calculated on standard weight. Lap length of bars & Weight of binding wire will not be considered for measurement and payment). Ground Floor 819.21 12.9 1.1 833.21 Qntl 9294.3 7744103.703 119896.47 0.0 7613983.503 Terrace 56.63 56.63 Qntl 9328.38 528266.1594 0.0 528266.1594 0.0 Second Floor 0.0 Qntl 9364.18 0.0 0.0 0.0 0.0 Third Floor 0.0 Qntl 9401.8 0.0 0.0 0.0 0.0 Fourth Floor 0.0 Qntl 9441.3 0.0 0.0 0.0 0.0 Fifth Floor 0.0 Qntl 9482.7 0.0 0.0 0.0 0.0 SiXth Floor 0.0 Qntl 9526.2 0.0 0.0 0.0 0.0 0.0 0.0 0.0 MASSONARY WORKS 0.0 0.0 0.0 |
| 24 | Providing and laying Brick masonry work in Superstructure using Fly ash bricks of 25 Cm. x 12 Cm. x 8 Cm. size having crushing strength not less than 75 Kg./Cm2 with dimensional tolerance + 2 % confirming to IS 12894 and IS 2212 in cement mortar (1:4) for Half Brick Masonry Wall with provisions for 2 nos 6mm dia MS bar at each 4th layer after immersing the bricks for minimum 6 hours in water before use, with all necessary projections, splays cutting, circular moulding, corbelling, etc. as per the drawings including the cost of all materials, cost of all labour, conveyance, royalties, loading, unloading, scaffolding, staging, watering and curing, sundries, T&P, etc. complete as per the direction of the Engineer-in-charge. ( Excluding Cost Of Steel Reinforcement ). Ground Floor 20.37 20.37 Cum 6072.7 123700.899 0.0 0.0 123700.899 Terrace 0.0 Cum 6458.6 0.0 0.0 0.0 0.0 Second Floor 0.0 Cum 6902.5 0.0 0.0 0.0 0.0 Third Floor 0.0 Cum 7413.0 0.0 0.0 0.0 0.0 Fourth Floor 0.0 Cum 8000.0 0.0 0.0 0.0 0.0 Fifth Floor 0.0 Cum 8675.1 0.0 0.0 0.0 0.0 SiXth Floor 0.0 Cum 9451.4 0.0 0.0 0.0 0.0 |
| 25 | Providing and laying of Full Brick Masonry work in Superstructure using Fly ash bricks of 25 Cm. x 12 Cm. x 8 Cm. size having crushing strength not less than 75 Kg./Cm2 with dimensional tolerance + 2 % confirming to IS 12894 and IS 2212 in cement mortar (1:6) affter immersing the bricks for minimum 6 hours in water before use, with all necessary projections, splays cutting, circular moulding, corbelling, etc. as per the drawings including the cost of all materials, cost of all labour, conveyance, royalties, loading, unloading, scaffolding, staging, watering and curing, sundries, T&P, etc. complete as per the direction of the Engineer-in-charge. Ground Floor 452.95 20.79 473.74 Cum 5849.1 2770952.634 121602.789 0.0 2649349.845 Terrace 129.38 129.38 Cum 6235.0 806684.2999999999 0.0 806684.2999999999 0.0 Second Floor 0.0 Cum 6678.9 0.0 0.0 0.0 0.0 Third Floor 0.0 Cum 7189.4 0.0 0.0 0.0 0.0 Fourth Floor 0.0 Cum 7776.4 0.0 0.0 0.0 0.0 Fifth Floor 0.0 Cum 8451.5 0.0 0.0 0.0 0.0 SiXth Floor 0.0 Cum 9227.8 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 FINISHING WORK 0.0 0.0 0.0 0.0 |
| 26 | Providing 6 mm thick Cement Plaster in Cement Mortar of (1:4) to Ceilings of Roof Slabs, Stairs, Landings, Chajja, Shelves, Columns, Beams and Lofts etc. including roughening, scraping and cleaning and finishing the plastered surface smooth using wooden floats only to proper plumbs and level, making grooves, beads and drip coarse to give required ornamental finish as per drawings including cost of all materials, conveyance, loading and unloading and royalties, all labour, scaffolding, watering and curing , sundries, T&P etc. complete as per direction of the Engineer-in-charge Ground Floor 0.0 63.68 63.68 Sqm 217.2 13831.295999999998 13831.295999999998 0.0 0.0 Terrace 0.0 0.0 Sqm 222.8 0.0 0.0 0.0 0.0 Second Floor 0.0 Sqm 228.6 0.0 0.0 0.0 0.0 Third Floor 0.0 Sqm 234.5 0.0 0.0 0.0 0.0 Fourth Floor 0.0 240.6 0.0 0.0 0.0 0.0 Fifth Floor 0.0 246.9 0.0 0.0 0.0 0.0 SiXth Floor 0.0 253.4 0.0 0.0 0.0 0.0 Providing 12mm thick cement plaster in cement mortar (1:4) to the surface of half brick masonry wall including racking out joints, scraping and cleaning the surface and finishing the plaster surface smooth using wooden floats, bars, etc only to proper plumbs and level and making grooves, beads and drip coarse to give required ornamental finish as per drawings including cost of all materials, conveyance, loading and unloading, royalties, cost of all labour, scaffolding, staging, watering before plastering and curing, sundries and T&P, etc. complete as per direction of the Engineer-in-charge. 0.0 0.0 0.0 0.0 Ground Floor 0.0 Sqm 207.1 0.0 0.0 0.0 0.0 Terrace 0.0 Sqm 211.9 0.0 0.0 0.0 0.0 Second Floor 0.0 Sqm 216.8 0.0 0.0 0.0 0.0 Third Floor 0.0 Sqm 221.9 0.0 0.0 0.0 0.0 Fourth Floor 0.0 Sqm 227.1 0.0 0.0 0.0 0.0 Fifth Floor 0.0 Sqm 232.5 0.0 0.0 0.0 0.0 SiXth Floor 0.0 Sqm 238.0 0.0 0.0 0.0 0.0 |
| 27 | Providing 16mm thick cement plaster in cement mortar (1:6) to the surfaces of brick masonry wall including racking out joints, scraping and cleaning the surface and finishing the plaster surface smooth using wooden floats, bars, etc only to proper plumbs and level and making grooves, beads and drip coarse to give required ornamental finish as per drawings including cost of all materials, conveyance, loading and unloading, royalties, cost of labour, scaffolding, staging, watering before plastering and curing, sundries and T&P, etc. complete as per direction of the Engineer-in-charge.(inner side) Ground Floor 2382.24 239.25 2621.49 Sqm 280.8 736114.392 67181.40000000001 0.0 668932.992 Terrace 750.14 750.14 Sqm 287.9 215965.30599999998 0.0 215965.30599999998 0.0 Second Floor 0.0 Sqm 295.3 0.0 0.0 0.0 0.0 Third Floor 0.0 Sqm 302.8 0.0 0.0 0.0 0.0 Fourth Floor 0.0 310.6 0.0 0.0 0.0 0.0 Fifth Floor 0.0 318.7 0.0 0.0 0.0 0.0 SiXth Floor 0.0 326.9 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 |
| 28 | Providing 12mm thick cement plaster in cement mortar (1:6) to the surface of brick masonry wall including racking out joints, scraping and cleaning the surface and finishing the plaster surface smooth using wooden floats, bars, etc only to proper plumbs and level and making grooves, beads and drip coarse to give required ornamental finish as per drawings including cost of all materials, conveyance, loading and unloading,royalties, cost of labour, scaffolding, staging, watering before plastering and curing, sundries and T&P, etc. complete as per direction of the Engineer-in-charge.(Outer side) Ground Floor 3122.28 3122.28 Sqm 194.5 607283.4600000001 0.0 0.0 607283.4600000001 Terrace 517.53 517.53 Sqm 202.5 104799.825 0.0 104799.825 0.0 Second Floor 0.0 Sqm 210.8 0.0 0.0 0.0 0.0 Third Floor 0.0 Sqm 219.6 0.0 0.0 0.0 0.0 Fourth Floor 0.0 Sqm 228.8 0.0 0.0 0.0 0.0 Fifth Floor 0.0 Sqm 238.4 0.0 0.0 0.0 0.0 SiXth Floor 0.0 Sqm 248.6 0.0 0.0 0.0 0.0 Providing 12mm thick cement plaster in cement mortar (1:4) with neat cement punning including racking out joints, scraping and cleaning the surface and finishing the plaster surface smooth using wooden floats, bars, etc only to proper plumbs and level and making grooves, beads and drip coarse to give required ornamental finish as per drawings including cost of all materials, conveyance, loading and unloading, taxes, royalties, cost of all labour, scaffolding, staging, watering before plastering and curing, sundries and T&P, etc. complete as per direction of the Engineer-in-charge. 0.0 0.0 0.0 0.0 Ground Floor 20.24 20.24 Sqm 215.2 4355.647999999999 0.0 0.0 0.0 Extra for plastering done on moulding, cornices or architraves including neat finish to lineand level: 0.0 0.0 0.0 0.0 0.0 Ground Floor 0.0 Sqm 659.0 0.0 0.0 0.0 0.0 Terrace 0.0 Sqm 659.0 0.0 0.0 0.0 0.0 Second Floor 0.0 Sqm 659.0 0.0 0.0 0.0 0.0 Third Floor 0.0 Sqm 659.0 0.0 0.0 0.0 0.0 Fourth Floor 0.0 Sqm 659.0 0.0 0.0 0.0 0.0 Fifth Floor 0.0 Sqm 659.0 0.0 0.0 0.0 0.0 SiXth Floor 0.0 Sqm 659.0 0.0 0.0 0.0 0.0 PLINTH PROTECTION 0.0 0.0 0.0 0.0 0.0 Making plinth protection 100 mm thick using of M20 grade cement concrete necessary excavation, levelling & dressing & finishing the top smooth. 0.0 0.0 0.0 0.0 0.0 (a)Ground Floor 0.0 cum 6678.26 0.0 0.0 0.0 0.0 0.0 0.0 0.0 |
| 29 | Providing average 25mm thick grading Concrete in C.C ( 1:2:2 ) using 6mm size crusher broken black hard granite chips using 2% water proofing cement compound of approved make after scraping and cleaning the roof surface and finishing smooth to proper slope and gradient including cost of all materials, conveyance, sundries,T&P watering and curing by ponding water over terrace slab etc. complete as per the direction of the Engineer-in-charge. Terrace 1770.98 1770.98 Sqm 427.3 756739.7540000001 0.0 756739.7540000001 Second Floor 0.0 Sqm 514.2 0.0 0.0 0.0 0.0 Third Floor 0.0 Sqm 567.7 0.0 0.0 0.0 0.0 Fourth Floor 0.0 Sqm 629.2 0.0 0.0 0.0 0.0 Fifth Floor 0.0 Sqm 699.9 0.0 0.0 0.0 0.0 SiXth Floor 0.0 Sqm 781.3 0.0 0.0 0.0 0.0 Providing and Laying of 2.5 cm. Damp proof course with C.C. (1:2:4) using 12mm. Size hard broken granite Chips including cost of all materials, conveyance, loading, unloading, royalties, taxes, cost of labours, T&P, hire & running charges for all leads as per direction of the engineer-in-charge. 0.0 0.0 0.0 0.0 0.0 Ground Floor 0.0 Sqm 391.7 0.0 0.0 0.0 0.0 Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. 0.0 0.0 0.0 0.0 0.0 Ground Floor 0.0 Kg 96.2 0.0 0.0 0.0 0.0 Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. (Mild steel tubes hot finished seamless type) 0.0 0.0 0.0 0.0 0.0 Ground Floor 0.0 KG 146.82 0.0 0.0 0.0 0.0 Supplying, filling, spreading & leveling stone boulders of size range 40 mm in recharge pit of required thickness including cost of material, labour, carriage, royalty, etc complete as directed by the Engineer-in-charge. 0.0 0.0 0.0 0.0 0.0 Ground Floor 0.6749999999999997 0.6749999999999997 Cum 2261.6 1526.5799999999992 0.0 0.0 0.0 Supplying, filling, spreading & leveling stone boulders of size range 20 mm in recharge pit of required thickness including cost of material, labour, carriage, royalty, etc complete as directed by the Engineer-in-charge. 0.0 0.0 0.0 0.0 0.0 Ground Floor 0.6749999999999997 0.6749999999999997 Cum 2711.1 1829.9924999999992 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 FINISHING WORK 0.0 0.0 0.0 0.0 0.0 0.0 0.0 |
| 30 | Supplying and finishing the plastered surface of wall using 2 Coats of Cement Based Wall Putty (Water Based) of approved make and quality and finished smooth and even surface to receive the paint including the cost of all materials, cost of all labour, conveyance, taxes, loading, unloading, scaffolding, T&P, etc, all complete as per the direction of Engineer-in-Charge. Interior Wall Putty 0.0 0.0 0.0 0.0 Ground Floor 4897.4 4897.4 Sqm 88.1 431460.93999999994 0.0 0.0 431460.93999999994 Terrace 0.0 0.0 Sqm 90.0 0.0 0.0 0.0 0.0 Second Floor 0.0 Sqm 92.0 0.0 0.0 0.0 0.0 Third Floor 0.0 Sqm 94.1 0.0 0.0 0.0 0.0 Fourth Floor 0.0 Sqm 96.2 0.0 0.0 0.0 0.0 Fifth Floor 0.0 Sqm 98.4 0.0 0.0 0.0 0.0 SiXth Floor 0.0 Sqm 100.6 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 Outer Wall Putty 0.0 0.0 0.0 0.0 0.0 Ground Floor 0.0 Sqm 0.0 0.0 0.0 0.0 0.0 Terrace 0.0 Sqm 0.0 0.0 0.0 0.0 0.0 Second Floor 0.0 Sqm 0.0 0.0 0.0 0.0 0.0 Third Floor 0.0 Sqm 0.0 0.0 0.0 0.0 0.0 Fourth Floor 0.0 Sqm 0.0 0.0 0.0 0.0 0.0 Fifth Floor 0.0 Sqm 0.0 0.0 0.0 0.0 0.0 SiXth Floor 0.0 Sqm 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 |
| 31 | Providing and applying 2 coats plastic emulsion paint of approved quality and shade over a coat of wall primer of approved quality to surfaces (interior) including throughly brushing the surface free from foreign materials, sand papering smooth the intermediate coats, providing necessary putty & primer including of all materials, labour, conveyance,royalties, scaffolding, watering, curing, sundries, tools and plants etc as per the direction of Engineer-in-charge. (colour & shade to be approved before procurment & use) Ground Floor 4919.97 4919.97 Sqm 194.1 954966.177 0.0 0.0 954966.177 First Floor 847.92 847.92 Sqm 198.4 168227.328 0.0 168227.328 0.0 Second Floor 0.0 Sqm 202.81 0.0 0.0 0.0 0.0 Third Floor 0.0 Sqm 207.3 0.0 0.0 0.0 0.0 Fourth Floor 0.0 Sqm 212.0 0.0 0.0 0.0 0.0 Fifth Floor 0.0 Sqm 216.8 0.0 0.0 0.0 0.0 SiXth Floor 0.0 Sqm 221.8 0.0 0.0 0.0 0.0 |
| 32 | Providing and Painting with Two Coats Weather Coat Paint (exterior grade) of approved make & shade manufactured by reputed manufacturer make an even finished surface over a coat of water bound cement primer in all heights with all scaffolding and staging charges including cost, conveyance, cost of all labours, T & P, sundries etc. as required for the work complete. Ground Floor 2473.17 302.93 2776.1 Sqm 186.2 516909.81999999995 56405.566 0.0 460504.25399999996 First Floor 532.8 532.8 Sqm 193.3 102990.23999999999 0.0 102990.23999999999 0.0 Second Floor 0.0 Sqm 200.8 0.0 0.0 0.0 0.0 Third Floor 0.0 Sqm 208.7 0.0 0.0 0.0 0.0 Fourth Floor 0.0 Sqm 216.9 0.0 0.0 0.0 0.0 Fifth Floor 0.0 Sqm 225.6 0.0 0.0 0.0 0.0 SiXth Floor 0.0 Sqm 234.7 0.0 0.0 0.0 0.0 |
| 33 | Painting two coats of synthetic enamel paint over Iron Works as per approved shade of approved quality over a coat of primer, sand papering, polishing the surface including cost, conveyance,labour, T&P, scaffolding etc. as required for the work complete as per direction of Engineer-in-charge. (The paints and primer are to be approved before procurement and use) Ground Floor 118.38 33.38 1.62 153.38 Sqm 268.7 41213.206 8969.206 0.0 31808.706 First Floor 17.22 17.22 Sqm 273.6 4711.392 0.0 4711.392 0.0 Second Floor 0.0 Sqm 278.6 0.0 0.0 0.0 0.0 Third Floor 0.0 Sqm 283.7 0.0 0.0 0.0 0.0 Fourth Floor 0.0 Sqm 289.0 0.0 0.0 0.0 0.0 Fifth Floor 0.0 Sqm 294.5 0.0 0.0 0.0 0.0 SiXth Floor 0.0 Sqm 300.1 0.0 0.0 0.0 0.0 Painting two coats of synthetic enamel paint on road work over Plaster or RCC Works like (kerb wall,bridge rcc barrier) as per approved shade of approved quality , sand papering, polishing the surface including cost, conveyance,labour, T&P, scaffolding etc. as required for the work complete as per direction of Engineer-in-charge. (The paints are to be approved before procurement and use) 0.0 0.0 0.0 0.0 0.0 Ground Floor 0.0 Sqm 84.5 0.0 0.0 0.0 0.0 Wall painting with Textured Paint of approved quality of pattern as specified in drawing including cost of all materials, labours ,T&P, carriage, royalty, taxes etc. required for the work all complete as per direction of Engineer-in-charge. 0.0 0.0 0.0 0.0 0.0 Ground Floor 0.0 Sqm 799.1 0.0 0.0 0.0 0.0 First Floor 0.0 Sqm 799.1 0.0 0.0 0.0 0.0 Second Floor 0.0 Sqm 799.1 0.0 0.0 0.0 0.0 Third Floor 0.0 Sqm 799.1 0.0 0.0 0.0 0.0 Fourth Floor 0.0 Sqm 799.1 0.0 0.0 0.0 0.0 Fifth Floor 0.0 Sqm 799.1 0.0 0.0 0.0 0.0 SiXth Floor 0.0 Sqm 799.1 0.0 0.0 0.0 0.0 FLOORING WORK 0.0 0.0 0.0 0.0 |
| 34 | Providing and laying of 600 mm x 600 mm Polished Vitrified floor tiles of premium grade having thickness 8 mm to 10mm conforming to IS 15622:2006 (GrPlain (Ivory) oup-B la) of following sizes. of approved make, quality and colour without any warpage laid over an under layer of 20 mm thick base of cement mortar (1:4) (1 cement: 4 coarse sand) including cutting to size, laying and filling the joints with white cement slurry mixed with colouring pigment to match the shade and colour, cleaning the surfaces including the cost of all materials, cost of all labour, conveyance, royalties, loading, unloading, sundries, watering and curing, T&P, etc. complete as per the direction of the Engineer-in-Charge.(Note- Sample of tiles shall be approved before procurement and use.) Ground Floor 1313.905625 1313.905625 Sqm 1152.5 1514276.2328125 0.0 0.0 1514276.2328125 First Floor 0.0 Sqm 1166.3 0.0 0.0 0.0 0.0 Second Floor 0.0 Sqm 1180.7 0.0 0.0 0.0 0.0 Third Floor 0.0 Sqm 1195.8 0.0 0.0 0.0 0.0 Fourth Floor 0.0 1211.7 0.0 0.0 0.0 0.0 Fifth Floor 0.0 1228.4 0.0 0.0 0.0 0.0 SiXth Floor 0.0 1245.9 0.0 0.0 0.0 0.0 0.0 0.0 0.0 |
| 35 | Providing and laying of 600 mm x 600 mm Anti skid matt finish Vitrified floor tiles of premium grade having thickness 8 mm to 10mm conforming to IS 15622:2006 (Group-B la) of following sizes. of approved make, quality and colour without any warpage laid over an under layer of 20 mm thick base of cement mortar (1:4) (1 cement: 4 coarse sand) including cutting to size, laying and filling the joints with white cement slurry mixed with colouring pigment to match the shade and colour, cleaning the surfaces including the cost of all materials, cost of all labour, conveyance, royalties, loading, unloading, sundries, watering and curing, T&P, etc. complete as per the direction of the Engineer-in-Charge.(Note- Sample of tiles shall be approved before procurement and use.) 0.0 0.0 0.0 |
| 36 | Providing and laying 300mmx300mm printed series ceramic floor tiles of premium grade having thickness 7mm to 8mm conforming to IS 13755 of approved make, quality and colour without any warpage laid over an under layer of 20 mm thick base of cement mortar (1:4) (1 cement: 4 coarse sand) including cutting to size, laying and spacer of 4mm for grouting the joints of tiles using epoxy grout mix of 0.70 kg of organic coated filler of desired shade (0.10 kg of hardener and 0.20 kg of resin per kg) to match the shade and colour, cleaning the surfaces with acid including the cost of all materials, cost of all labour, conveyance, royalties, loading, unloading, sundries, watering and curing, T&P, etc. complete as per the direction of the Engineer-in-Charge.(Note- Sample of tiles shall be approved before procurement and use.) Ground Floor 80.91 80.91 Sqm 1106.2 89502.642 0.0 0.0 89502.642 First Floor 0.0 Sqm 1119.9 0.0 0.0 0.0 0.0 Second Floor 0.0 Sqm 1134.3 0.0 0.0 0.0 0.0 Third Floor 0.0 Sqm 1149.5 0.0 0.0 0.0 0.0 Fourth Floor 0.0 Sqm 1165.4 0.0 0.0 0.0 0.0 Fifth Floor 0.0 Sqm 1182.1 0.0 0.0 0.0 0.0 SiXth Floor 0.0 Sqm 1199.6 0.0 0.0 0.0 0.0 0.0 0.0 0.0 |
| 37 | Providing & laying Heavy Duty Industrial Vetrified Tile having thickness 8 mm to 10mm in floor/dado/skirting confirming to IS : 15622 of size 300mmx300mm of approved make, quality and colour without any warpage laid over an under layer of 12mm thick cement mortar (1:3) (1 cement: 3 coarse sand) confirming to IS-1443 including cutting to size, laying and filling the joints with white cement slurry mixed with colouring pigment to match the shade and colour, cleaning the surfaces including the cost of all materials, cost of all labour, conveyance, taxes, royalties, loading, unloading, sundries, watering and curing, T&P, etc. complete as per the direction of the Engineer-in-Charge.(Note- Sample of tiles shall be approved before procurement and use.) Ground Floor 54.13 54.13 Sqm 1204.4 65194.172000000006 0.0 0.0 65194.172000000006 Providing and laying Chequred Tiles. tiles confirming to IS : 15622 of approved make, quality and colour without any warpage laid over 20 mm thick base of cement mortar (1:4) (1 cement: 4 coarse sand) including cutting to size, laying and filling the joints with white cement slurry mixed with colouring pigment to match the shade and colour, cleaning the surfaces including the cost of all materials, cost of all labour, conveyance, taxes, royalties, loading, unloading, sundries, watering and curing, T&P, etc. complete as per the direction of the Engineer-in-Charge.(Note- Sample of tiles shall be approved before procurement and use.) 0.0 0.0 0.0 0.0 Ground Floor 0.0 Sqm 665.2 0.0 0.0 0.0 0.0 First Floor 0.0 Sqm 678.9 0.0 0.0 0.0 0.0 Providing & laying granite stone flooring using 19-20 mm thick granite stone slab of approved quality, colour and size above 0.4 Sqm as per IS 14223 in Stair Treads and Risers over an under layer of 20 mm thick cement mortar (1:4) (1 cement: 4 coarse sand) confirming to IS-1443 including cutting to size, laying and joining with white cement slurry and colouring pigment to match the shade with typical half nosing and cutting grooves etc including cost of all labour, materials, royalties, loading and unloading, conveyance, sundries, watering and curing, etc. complete as per the direction of the Engineer-in-Charge. (Note- Sample of granite tiles shall be approved before procurement and use.) 0.0 0.0 0.0 0.0 Ground Floor 0.0 Sqm 3210.9 0.0 0.0 0.0 0.0 First Floor 0.0 Sqm 3244.1 0.0 0.0 0.0 0.0 Second Floor 0.0 Sqm 3279.0 0.0 0.0 0.0 0.0 Third Floor 0.0 Sqm 3315.6 0.0 0.0 0.0 0.0 Fourth Floor 0.0 Sqm 3354.0 0.0 0.0 0.0 0.0 Fifth Floor 0.0 Sqm 3394.4 0.0 0.0 0.0 0.0 SiXth Floor 0.0 Sqm 3436.8 0.0 0.0 0.0 0.0 |
| 38 | Providing & laying granite stone flooring in Floors and landing using 19-20 mm thick granite stone slab of approved quality, colour and size above 0.4 Sqm as per IS 14223 laid over an under layer of 20 mm thick cement mortar (1:4) (1 cement: 4 coarse sand) confirming to IS-1443 including cutting to size, laying and filling the joints with white cement slurry mixed with colouring pigment to match the shade and colour, cleaning the surfaces including the cost of all materials, cost of all labour, conveyance, royalties, loading, unloading, sundries, watering and curing, T&P, etc. complete as per the direction of the Engineer-in-Charge.(Note- Sample of granite tiles shall be approved before procurement and use.) Ground Floor 14.35 14.35 Sqm 3154.6 45268.509999999995 0.0 0.0 45268.509999999995 First Floor 0.0 Sqm 3185.0 0.0 0.0 0.0 0.0 Second Floor 0.0 Sqm 3216.9 0.0 0.0 0.0 0.0 Third Floor 0.0 Sqm 3250.4 0.0 0.0 0.0 0.0 Fourth Floor 0.0 3285.6 0.0 0.0 0.0 0.0 Fifth Floor 0.0 3322.6 0.0 0.0 0.0 0.0 SiXth Floor 0.0 3361.4 0.0 0.0 0.0 0.0 Providing & laying granite stone tiles in dado/skirting using 10mm thick granite stone slab of approved quality, colour and size upto 0.4 Sqm as per IS 14223 to proper line, level and slope laid over 12mm thick cement mortar (1: 3) confirming to IS IS-1443 including cutting to size, laying and filling the joints with white cement slurry mixed with colouring pigment to match the shade and colour, cleaning the surfaces including the cost of all materials, cost of all labour, conveyance, royalties, loading, unloading, sundries, watering and curing, T&P, etc. complete as per the direction of the Engineer-in-Charge.(Note- Sample of granite tiles shall be approved before procurement and use.) 0.0 0.0 0.0 0.0 0.0 Ground Floor 0.0 Sqm 2536.0 0.0 0.0 0.0 0.0 First Floor 0.0 Sqm 2579.7 0.0 0.0 0.0 0.0 Second Floor 0.0 Sqm 2625.6 0.0 0.0 0.0 0.0 Third Floor 0.0 Sqm 2673.7 0.0 0.0 0.0 0.0 Fourth Floor 0.0 Sqm 2724.3 0.0 0.0 0.0 0.0 Fifth Floor 0.0 Sqm 2777.4 0.0 0.0 0.0 0.0 SiXth Floor 0.0 Sqm 2833.2 0.0 0.0 0.0 0.0 0.0 0.0 0.0 |
| 39 | Providing & laying kota stone slabs in floors using 16 mm thick kota stone slab of approved quality, colour and size above 0.10 Sqm laid over an under layer of 20 mm thick cement mortar (1:4) (1 cement : 4 coarse sand) confirming to IS-1443 including cutting to size, laying and filling the joints with white cement slurry mixed with colouring pigment to match the shade and colour, cleaning the surfaces including the cost of all materials, cost of all labour, conveyance, taxes, royalties, loading, unloading, sundries, watering and curing, T&P, etc. complete as per the direction of the Engineer-in-Charge.(Note- Sample of tiles shall be approved before procurement and use.) Ground Floor 184.63625000000002 184.63625000000002 Sqm 1297.8 239620.92525000003 0.0 0.0 239620.92525000003 First Floor 0.0 Sqm 1328.2 0.0 0.0 0.0 0.0 Second Floor 0.0 Sqm 1360.1 0.0 0.0 0.0 0.0 Mumty Floor 0.0 Sqm 1393.6 0.0 0.0 0.0 0.0 0.0 0.0 0.0 DADO/SKIRTING WORK 0.0 0.0 0.0 |
| 40 | Providing and laying of Polished Vitrified floor tiles of premium grade having thickness 8 mm to 10mm conforming to IS 15622:2006 (GrPlain (Ivory) oup-B la) in dado/skirting confirming to IS : 15622 of approved make, quality, colour and size 600mm x600mm upto required height from floor level fixed over an under layer of 12mm thick bed of cement mortar (1:3) (1 Cement : 3 Coarse sand) including cutting to size, laying and filling the joints with white cement slurry mixed with colouring pigment to match the shade and colour, cleaning the surfaces including the cost of all materials, cost of all labour, conveyance, taxes, royalties, loading, unloading, sundries, watering and curing, T&P, etc. complete as per the direction of the Engineer-in-Charge.(Note- Sample of tiles shall be approved before procurement and use.) Ground Floor 136.8465 136.8465 Sqm 1288.9 176381.45385 0.0 0.0 176381.45385 First Floor 0.0 Sqm 1309.6 0.0 0.0 0.0 0.0 Second Floor 0.0 Sqm 1331.2 0.0 0.0 0.0 0.0 Third Floor 0.0 Sqm 1354.0 0.0 0.0 0.0 0.0 Fourth Floor 0.0 1377.9 0.0 0.0 0.0 0.0 Fifth Floor 0.0 1403.0 0.0 0.0 0.0 0.0 SiXth Floor 0.0 1429.4 0.0 0.0 0.0 0.0 0.0 0.0 0.0 |
| 41 | Ceramic wall tile With Epoxy Grout For ToiletProviding and laying of printed series ceramic floor tiles of premium grade having thickness 7mm to 8mm conforming to IS 13755 in dado/skirting confirming to IS : 15622 of approved make, quality, colour and size 300mm x 300mm upto required height from floor level fixed over an under layer of 12mm thick bed of cement mortar (1:3) (1 Cement : 3 Coarse sand) including cutting to size, laying and spacer of 4mm for grouting the joints of tiles using epoxy grout mix of 0.70 kg of organic coated filler of desired shade (0.10 kg of hardener and 0.20 kg of resin per kg) to match the shade and colour, cleaning the surfaces with acid including the cost of all materials, cost of all labour, conveyance, taxes, royalties, loading, unloading, sundries, watering and curing, T&P, etc. complete as per the direction of the Engineer-in-Charge.(Note- Sample of tiles shall be approved before procurement and use.) Ground Floor 319.18 319.18 Sqm 1131.6 361184.088 0.0 0.0 361184.088 First Floor 0.0 Sqm 1152.2 0.0 0.0 0.0 0.0 Second Floor 0.0 Sqm 1173.9 0.0 0.0 0.0 0.0 Third Floor 0.0 Sqm 1196.7 0.0 0.0 0.0 0.0 Fourth Floor 0.0 Sqm 1220.6 0.0 0.0 0.0 0.0 Fifth Floor 0.0 Sqm 1245.7 0.0 0.0 0.0 0.0 SiXth Floor 0.0 Sqm 1272.0 0.0 0.0 0.0 0.0 Ceramic wall tile Without Epoxy GroutProviding and laying of Glazed Ceramic Wall Tiles in dado/skirting confirming to IS : 15622 of approved make, quality, colour and size 400mm x 300mm upto required height from floor level fixed over an under layer of 12mm thick bed of cement mortar (1:3) (1 Cement : 3 Coarse sand) including cutting to size, laying and filling the joints with white cement slurry mixed with colouring pigment to match the shade and colour, cleaning the surfaces including the cost of all materials, cost of all labour, conveyance, taxes, royalties, loading, unloading, sundries, watering and curing, T&P, etc. complete as per the direction of the Engineer-in-Charge.(Note- Sample of tiles shall be approved before procurement and use.) 0.0 0.0 0.0 0.0 0.0 Ground Floor 0.0 Sqm 1007.6 0.0 0.0 0.0 0.0 First Floor 0.0 Sqm 1028.2 0.0 0.0 0.0 0.0 Second Floor 0.0 Sqm 1049.9 0.0 0.0 0.0 0.0 Mumty Floor 0.0 Sqm 1072.7 0.0 0.0 0.0 0.0 0.0 0.0 0.0 |
| 42 | Providing & laying kota stone slabs in dado/Skirting using 16 mm thick Kota stone of approved quality, colour and size above 0.10 Sqm laid over an under layer of 12mm thick cement mortar (1:3) (1 cement: 3 coarse sand) confirming to IS-1443 including cutting to size, laying and filling the joints with white cement slurry mixed with colouring pigment to match the shade and colour, cleaning the surfaces including the cost of all materials, cost of all labour, conveyance, taxes, royalties, loading, unloading, sundries, watering and curing, T&P, etc. complete as per the direction of the Engineer-in-Charge.(Note- Sample of tiles shall be approved before procurement and use.) Ground Floor 49.367699999999985 49.367699999999985 Sqm 1574.4 77724.50687999999 0.0 0.0 77724.50687999999 First Floor 0.0 Sqm 1618.1 0.0 0.0 0.0 0.0 Second Floor 0.0 Sqm 1664.0 0.0 0.0 0.0 0.0 Mumty Floor 0.0 Sqm 1712.2 0.0 0.0 0.0 0.0 BUILT IN JOINERIES 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 |
| 43 | Providing edge moulding and groove cutting in granite tiles as per drawing and design for granite stone counters, steps, Vanities etc., including machine polishing to edge to give high gloss finish etc. complete as per direction of Engineer-in-Charge. 0.0 0.0 0.0 DOOR & CHOUKATH WORKS 0.0 0.0 0.0 |
| 44 | Providing and fixing 65mm X 125mm factory made single extruded WPC (Wood Polymer Composite) solid door/window/Ceosetory windows & other Frames/Chowkhat comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modulus of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with M.S hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-In- Charge.Note: For WPC solid door/window frames, minus 5mm tolerance in dimensions i.e depth and width of profile shall be acceptable. Variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be made. Ground Floor 234.55 234.55 Rmt 1252.4 293750.42000000004 0.0 0.0 293750.42000000004 First Floor 0.0 Rmt 1252.4 0.0 0.0 0.0 0.0 Second Floor 0.0 Rmt 1252.4 0.0 0.0 0.0 0.0 Third Floor 0.0 Rmt 1252.4 0.0 0.0 0.0 0.0 Fourth Floor 0.0 Rmt 1252.4 0.0 0.0 0.0 0.0 Fifth Floor 0.0 Rmt 1252.4 0.0 0.0 0.0 0.0 SiXth Floor 0.0 Rmt 1252.4 0.0 0.0 0.0 0.0 Supplying, fitting and fixing of 32mm thick flush door shutter with approved quality of 30mm thick BWR block board pasted with 1mm thick sunmica on both side of approved design and quality including cost of all door fittings and fixtures etc. complete 0.0 0.0 0.0 0.0 0.0 Ground Floor 0.0 Sqm 10668.61 0.0 0.0 0.0 0.0 First Floor 0.0 Sqm 10668.61 0.0 0.0 0.0 0.0 Second Floor 0.0 Sqm 10668.61 0.0 0.0 0.0 0.0 Third Floor 0.0 Sqm 10668.61 0.0 0.0 0.0 0.0 Fourth Floor 0.0 Sqm 10668.61 0.0 0.0 0.0 0.0 Fifth Floor 0.0 Sqm 10668.61 0.0 0.0 0.0 0.0 SiXth Floor 0.0 Sqm 10668.61 0.0 0.0 0.0 0.0 |
| 45 | Providing and fixing 45mm X 75mm or 90 mm x 50 mm factory made single extruded WPC (Wood Polymer Composite) solid door/window/Ceosetory windows & other Frames/Chowkhat comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modulus of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with M.S hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-In- Charge.Note: For WPC solid door/window frames, minus 5mm tolerance in dimensions i.e depth and width of profile shall be acceptable. Variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be made. Ground Floor 74.25 74.25 Rmt 720.96 53531.280000000006 0.0 0.0 53531.280000000006 First Floor 0.0 Rmt 720.96 0.0 0.0 0.0 0.0 Second Floor 0.0 Rmt 720.96 0.0 0.0 0.0 0.0 Mumty Floor 0.0 Rmt 720.96 0.0 0.0 0.0 0.0 |
| 46 | Providing and fixing factory made single extruded 30 MM THICK WPC (Wood Polymer Composite) solid plain flush door shutter of required size comprising of virgin polymer of K value 58-60(Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheathusk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimumdensity of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge),minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/ moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per directionof Engineer-In- Charge.(Make: WPC: Century / Black Cobra / Rajshri Plastiwood, Hardware Fittings: Godrej / Dorset / Link / Dorma) Ground Floor 23.63 23.63 Sqm 4106.26 97030.9238 0.0 0.0 97030.9238 |
| 47 | Providing and fixing factory made single extruded 35 MM THICK WPC (Wood Polymer Composite) solid plain flush door shutter of required size comprising of virgin polymer of K value 58-60(Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/ moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer-In- Charge. (Make: WPC: Century / Black Cobra / Rajshri Plastiwood, Hardware Fittings: Godrej / Dorset / Link / Dorma) Ground Floor 104.48 104.48 Sqm 4961.3 518356.624 0.0 0.0 518356.624 First Floor 0.0 Sqm 4961.3 0.0 0.0 0.0 0.0 Mumty Floor 0.0 Sqm 4961.3 0.0 0.0 0.0 0.0 Supplying and fitting-fixing of factory made single leaf rigid FRP (alternately called GRP) sandwich composite door shutter of 32mm thick laminated with two GRP skins with wood grain finish fabricated using UV-stabilised Isopthalic Gelcoat and one layer of 450 gsm E-glass Chopped Strand Mat (CSM) impregnated with orthopthalic palyester resin. The thickness of the skins shall not be less than 3.00 mm Expanded Polystyrone(EPS) structural foam panel of 29mm thickness and a density of 20kg/cu.mtr shall be used as core material. Wooden reinforcements made of seasoned sal wood block of cross section not less than 28mmx32mm and also necessary sal wood reinforcements for fitting the metal fittings such as tower bolts, aldrops, handles etc shall be provided. A structural adhesive compatible with (EPS) foam shall be used for bending the core material, the sal wood reiforcements and the skins. The material and process for manufacturing the door shutters shall conform to RV-TIFAC composites Design Centre's standards and specifications and the door shutters tested in conformation to IS: 4020-1998. The finish of door shutter will be plain colour white/ Ivory/ Beige/ Light grey/ Mahogany/ Teak wood or any other colour using high quality pigments. Three heavy whight mild steel butt hinges type-I(ISI marked) size 100mm are to be fitted on one side of shutter. 0.0 0.0 0.0 0.0 0.0 Ground Floor 0.0 Sqm 6172.1 0.0 0.0 0.0 0.0 First Floor 0.0 Sqm 6172.1 0.0 0.0 0.0 0.0 Second Floor 0.0 Sqm 6172.1 0.0 0.0 0.0 0.0 Third Floor 0.0 Sqm 6172.1 0.0 0.0 0.0 0.0 Fourth Floor 0.0 Sqm 6172.1 0.0 0.0 0.0 0.0 Fifth Floor 0.0 Sqm 6172.1 0.0 0.0 0.0 0.0 SiXth Floor 0.0 Sqm 6172.1 0.0 0.0 0.0 0.0 Providing and fixing factory made 2.5 track KOMMERLING UPVC white colour sliding window with SS mesh comprising of uPVC multi-chambered frame having section Frame 88mm x 49mm, Window sash: 37mm x 61mm, Bugmesh sash: 58mm x 32mm made out of lead free green profiles with comers fusion welded, fully reinforced with Galvanized steel 1.5 mm. The windows profile should fulfill the requirements of Viny 2010. The physical properties of the profiles like Vicat softening temperature, density, tensile strength, hardness, weatherability, impact strength and Modulus of Elasticity should be tested in accordance with ASTM/DIN-ISO standards and the thermal conductivity as per IS standards. The window comprising of uPVC extruded glazing beads of appropriate dimension, EPDM gasket, G.I fasteners 100 x 8 mm size for fixing frame to finished wall, plastic packers, plastic caps and necessary stainless steel screws etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of required size. The sash will be fitted with 5mm clear glass 0.0 0.0 0.0 0.0 0.0 Ground Floor 0.0 Sqm 8900.0 0.0 0.0 0.0 0.0 First Floor 0.0 Sqm 8900.0 0.0 0.0 0.0 0.0 Second Floor 0.0 Sqm 8900.0 0.0 0.0 0.0 0.0 Third Floor 0.0 Sqm 8900.0 0.0 0.0 0.0 0.0 Fourth Floor 0.0 Sqm 8900.0 0.0 0.0 0.0 0.0 Fifth Floor 0.0 Sqm 8900.0 0.0 0.0 0.0 0.0 SiXth Floor 0.0 Sqm 8900.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 |
| 48 | Supplying and fixing of Powder coated 50-60 microns approved colour of aluminium 40mm Casement series Door Unit with suitable aluminium extrude profiles. the system is designed to accommodate 12mm clear toughened glass. the rate quoted inclusive of hardwares like antilift, roller, Espag lock cum handle, epdm gaskets, T mullion, Fly Mullion, bottom adopter, mid transom, glazing clip for 12 mm glass felt along with all accessories etc complete. The gap between the wall and window will be filled with silicon weather sealant in the outer side. including the cost of all materials ,hardware fittings,cost of all labour, conveyance, loading, un loading, T&P, etc, complete as per the direction of Engineer-in Charge.(As per Proceeding of C.C.E. Level committee meeting held on dt. 12.02.2024 at 11.30 A.M.) Ground Floor 8.64 8.64 Sqm 12427.8 107376.192 0.0 0.0 107376.192 0.0 0.0 0.0 WINDOW & VENTILATOR WORKS 0.0 0.0 0.0 0.0 0.0 0.0 |
| 49 | Supplying , fitting and fixing of two track UPVC sliding window of approved make with 6mm thick glass of approved quality complete with frame, shutters and all fitting and fixtures.. complete in all respect as per the direction of the Engineer-in-Charge. Ground Floor 149.02 149.02 Sqm 4960.97 739283.7494000001 0.0 0.0 739283.7494000001 First Floor 0.0 Sqm 4960.97 0.0 0.0 0.0 0.0 Second Floor 0.0 Sqm 4960.97 0.0 0.0 0.0 0.0 Third Floor 0.0 Sqm 4960.97 0.0 0.0 0.0 0.0 Fourth Floor 0.0 Sqm 4960.97 0.0 0.0 0.0 0.0 Fifth Floor 0.0 Sqm 4960.97 0.0 0.0 0.0 0.0 SiXth Floor 0.0 Sqm 4960.97 0.0 0.0 0.0 0.0 0.0 0.0 0.0 |
| 50 | Supplying and fitting -fixing of Un-plasticised poly Vinyl Chloride (UPVC) (FENESTA/NCL VECCA LTD) Ventillator/Top Hung-60 Series duly manufactured using UPVC reinforced Profiles of 60mmx 55mmx2.5mm for outer frames ,75mmx60mmx2.25mm for casement window sash profile capable of mounting single glazing system,structurally reinforced with hot dip galvanised upto 50 microns of minimum thickness of 1.5 mm prefabricted and welded through fusion welding the wwindow sash shall be fitted with 6mm thick clear toughened glass of Saint-Gobain make duly fixed with EPDM weathering seal resistant accessories like clipping locking system made of aluminium 1 no per set of sashes and the system to be installed at the site using anchor fasteners,silicon rubber sealant,easy glazing/deglazing at siteetc including cost and conveyance of all accessories labour charges,materials and product confirming to ASTM D 638-14,EN-477-95 and other applicable codes and standards. Ground Floor 6.48 6.48 Sqm 7115.0 46105.200000000004 0.0 0.0 46105.200000000004 Supplying, fitting and fixing of UPVC Partition Wall I60 Casement Series 1-OFF as per drawing and specification: Top member-6mm Tinted/Laminated/Colored/Clear Toughened Glass & Bottom member-PVC Sheet (12-18mm), Weight: 291.36 kg, Colour-White Dimension Type-Frame Size from RO, Frame Depth-60mm, Hinged Series-I60 Casement, Reinforcement-Full, Coupling 180-33mm/2108-3106+56016-10070, Window O/F-55mm/41101-11000+R1, Frame T/M-74mm/41101-12000/12100+56016-10001, T-Joins-Mechanical, Frame Mech-50502-11016, Connector-Shape 1, Bead Shape-Glazing Packer 16.5 x 77 x 5 mm, Cmnt Gl Packer-No, Grill required-Supply & Install, Supply Type-280ml bottle, Silicon Sealant-No, Display Fixings-Face with drainage including scaffolding complete in all respect as per the direction of the Engineer-in-Charge. 0.0 0.0 0.0 0.0 0.0 Ground Floor 0.0 Sqm 4142.68 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 Providing and fixing 12 mm thick frame less toughened glass partition Dorma Premium (911298) PT 90 Side Connector and PT 80 Glass to glass Connector with Silicone,12mm Clear Toughened Glass with Cutout and Hole,including perimeter sealing of glass to glass joints with silicon sealant ,etc.as per drawing and specification including the cost of all materials ,T&P,etc all complete as per the direction of Engineer-in-Charge. 0.0 0.0 0.0 0.0 0.0 Ground Floor 0.0 Sqm 10223.2 0.0 0.0 0.0 0.0 Providing and fixing of 12mm thick Clear Toughened Glass Frameless Door With Dorma Premium Fittings. Dorma Premium (9111198) Unilite Package BTS 75 UL PT 10 with Cover, UL PT 20 with Cover UL US 10 Luck with Cover and PT. 24. Dorma Premium (9137121) H Type Handle 450mm, 12mm Clear Toughened Glass with Cutout and Hole including the cost of ali materials hardware fittings, cost of all labour, conveyance. loading, unloading. T&P, etc, complete as per the direction of Engineer-in-Charge 0.0 0.0 0.0 0.0 0.0 Ground Floor 0.0 Sqm 11343.2 0.0 0.0 0.0 0.0 0.0 0.0 0.0 STRUCTURAL STEEL & GLAZING WORKS 0.0 0.0 0.0 |
| 51 | Supplying, fitting & fixing of M.S grills for (windows, ventilators & grill gates) madeout of M.S angle/M.S flat/M.S solid bar/M.S sections including cost of screws as per approved design & dimensions, electrically welded properly with all locking arrangrments including cost of materials, labour, carriage etc. complete as per the direction of the Engineer-in-Charge. Ground Floor 4640.0 1668.75 32.400000000000006 6341.15 Kg 89.61 568230.4515 149536.6875 0.0 415790.4 Terrace 344.4 344.4 Kg 89.61 30861.683999999997 0.0 30861.683999999997 0.0 Second Floor 0.0 Kg 89.61 0.0 0.0 0.0 0.0 Third Floor 0.0 Kg 89.61 0.0 0.0 0.0 0.0 Fourth Floor 0.0 Kg 89.61 0.0 0.0 0.0 0.0 Fifth Floor 0.0 Kg 89.61 0.0 0.0 0.0 0.0 SiXth Floor 0.0 Kg 89.61 0.0 0.0 0.0 0.0 S.S Railing 0.0 0.0 0.0 0.0 |
| 52 | Supplying, fabricating & fixing of polished stainless steel (304 grade) items made out of pipes, angles, flats, plates, hollow tube, square pipe bracing as per approved design and specification, buffing, polishing etc. with cost, conveyance, labour in railing, parapet, staircase, space frame etc required for the work complete in all respect as per direction of Engineer-in-charge. Ground Floor 403.1 403.1 Kg 343.8 138585.78 0.0 0.0 138585.78 Terrace 0.0 Kg 343.8 0.0 0.0 0.0 0.0 Second Floor 0.0 Kg 343.8 0.0 0.0 0.0 0.0 Third Floor 0.0 Kg 343.8 0.0 0.0 0.0 0.0 Fourth Floor 0.0 Kg 343.8 0.0 0.0 0.0 0.0 Fifth Floor 0.0 Kg 343.8 0.0 0.0 0.0 0.0 SiXth Floor 0.0 Kg 343.8 0.0 0.0 0.0 0.0 G.R.C. JALI :-Providing and fixing Glass Reinforced Concrete (GR.C) Screens in approved size pattern, design, shadeand thickness of 50mm on frame and design element in 30mm thick have weight approximately between 3.5 4 Kg per Sq Ft and color of M/S UniStone make or equivalent. The above weight and thickness is considering dimensions of screens up to 2133mm in height and 1219mm in width and having at least 50% void space. The screens should be made from '53 grade' White Portland Cement manufactured by JK Cement' or equivalent, Quartz, Fine Silica Sand, Alkali Resistant Glass Fiber manufactured by 'N.E.G JAPAN or equivalent, Super Plasticizers manufactured by \\"BASF or equivalent Polymers manufactured by 'BASF or equivalent and UV resistant Synthetic inorganic pigments should be used for pigmentation manufactured by 'BAYFERROX (Germany) or equivalent. The material casting should take place in FRP Molds. The fixing of Screens should be 'Dry fixing' Le to be done with M.S Galvanized Clamps, fixtures and fasteners of Hilti / Fischer. 0.0 0.0 0.0 0.0 0.0 Ground Floor 0.0 Kg 8711.3 0.0 0.0 0.0 0.0 First Floor 0.0 Kg 8711.3 0.0 0.0 0.0 0.0 Second Floor 0.0 Kg 8711.3 0.0 0.0 0.0 0.0 TERACE/TOILET WATERPROOFING WORK 0.0 0.0 0.0 0.0 0.0 modified cementitious waterproofing coating over roof slab/Toilet after carrying out pond test on roof slab/Toilet, filling all defects, saturating the surface, mixing the products and then application in 2.0 mm thickness (1.8 Kg / sqm coverage rate for 1.0 mm thickness) in suitable layers complete in all respect, all materials, tools, plant & labour complete in all respect. Density 1850kg/m³ , Mix ratio (Powder to liquid) 3:1 by weight ,Water penetration Din 1048 1.5 Bar no leakage Potlife @ 25°C 2 hours & @ 40°C 30 minutes,Recoatable: 8-12 hours Elongation >42% (air) & >31% (under water),Tensile strength >20 kg/cm2 ,VOC content (HK prod code P10-17) 0.5 g/L including cost of all materials, conveyance, taxes and sundries,T&P, watering and curing by ponding water over terrace slab etc. complete as per the direction of the Engineer-in-charge. 0.0 0.0 0.0 0.0 0.0 Ground Floor 0.0 Sqm 543.6 0.0 0.0 0.0 0.0 Terrace 0.0 Sqm 543.6 0.0 0.0 0.0 0.0 Second Floor 0.0 Sqm 543.6 0.0 0.0 0.0 0.0 Third Floor 0.0 Sqm 543.6 0.0 0.0 0.0 0.0 Fourth Floor 0.0 Sqm 543.6 0.0 0.0 0.0 0.0 Fifth Floor 0.0 Sqm 543.6 0.0 0.0 0.0 0.0 SiXth Floor 0.0 Sqm 543.6 0.0 0.0 0.0 0.0 Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. 0.0 0.0 0.0 0.0 0.0 Ground Floor 0.0 Sqm 96.1 0.0 0.0 0.0 0.0 Supplying and fixing of Colour coated galvalume metal sheets Zinc aluminum alloy coated, Not less than 150 gms/sq.m, having high tensile steel sheet (Fy 550 Mpa) of 0.5 mm minimum thickness (BMT). The outside face (exposed face) shall be permanently color coated with PVF-2 paint of minimum DFT 20 microns over primer and inner side (internal face) shall be coated with same paint of minimum DFT 12 microns ,Colour Coated Flashing & Ridge board with all fasteners and fixtures, scaffolding etc. complete at all heights as per drawings and specification including preparation of bill of materials & shop drawings. (Galvalume Sheets shall be of any reputed make including Kingspan Jindal/'Tata Blue Scope Steel Limited', 'Laj Color Leaf (P) Limited' Loyd Insulations etc.) 0.0 0.0 0.0 0.0 0.0 Ground Floor 0.0 Sqm 1231.2 0.0 0.0 0.0 0.0 Micro Concreting1. Surface PreparationRemoving all loose and unsound concrete from the damaged area by mechanical means/manual chipping without damaging the parent concrete.Cleaning of reinforcement with rust remover to remove all loose rust and scale.2. Steel ProtectionApplication of zinc-rich primer over cleaned reinforcement steel to prevent further corrosion.3. Bonding CoatApplication of bond coat consisting of cement slurry mixed with SBR Latex (Dr. Fixit Pidicrete URP or equivalent) over the prepared surface to ensure proper bonding between old and new concrete.4. Repair Mortar / Micro ConcreteFilling of repaired pockets with Polymer Modified Mortar (PMM) for small thickness repairs.For larger sections, use Dr. Fixit Micro Concrete to restore the structural profile.5. Waterproofing TestAfter repairs, carry out ponding test on the opposite surface of the roof slab to check for any leakage/seepage.6. Injection GroutingIn case of observed seepage/leakage, carry out pressure injection grouting with suitable grout material (epoxy as specified) to arrest water ingressComplete as per the direction of the Engineer-in-Charge. (Note- Sample of materials shall be approved before procurement and use.) 0.0 0.0 0.0 0.0 0.0 Ground Floor 0.0 Sqm 3891.0 0.0 0.0 0.0 0.0 Groove cut the existing crack on concrete/masonry surface and remove all dust and loose particles, fill the cracks with Renderoc FC and inject the cracks by pressure grouting using Conbextra Cable Grout using PVC nozzles at speed less than 1 kg/cm2, Cut slits of 3 to 5mm width on the joints of crack line to depth of 15mm and 155mm on either side of crack, fill the groove with Renderoc SP40 and insert Nitoplate Crackfix plate having tensile strength >1000 MPA, fiber content 50 - 60% into the filled groove. Item rate is inclusive of materials all labour, tools and tackles, and transportation etc. complete as per specification and as directed by Engg.-in-charge. Payment shall be made as per actual site measurement.(Note- Sample of materials shall be approved before procurement and use.) 0.0 0.0 0.0 0.0 0.0 all Floor 0.0 Rmt 731.7 0.0 0.0 0.0 0.0 Providing and fixing GI chicken wire mesh 24 gauge and 12 mm mesh and required wideth for construction joints and chasing in brick work for electrical conduits or water supply pipes including cement slurry and pegs/nails with nailing machine as required before pastering etc. complete as directed by the Engineer-in-charge.(Note- Sample of materials shall be approved before procurement and use.) 0.0 0.0 0.0 0.0 0.0 all Floor 0.0 Rmt 186.0 0.0 0.0 0.0 0.0 Chequred Tiles 300mmx300mm of approved make, quality and colour without any warpage laid over an under layer of 20 mm thick base of cement mortar (1:4) (1 cement: 4 coarse sand) including cutting to size, laying and filling the joints with white cement slurry mixed with colouring pigment to match the shade and colour, cleaning the surfaces with oxlaic acid, machine grinding, mirror polishing including the cost of all materials, cost of all labour, conveyance, royalties, loading, unloading, sundries, watering and curing, T&P, etc. complete as per the direction of the Engineer-in-Charge.(Note- Sample of tiles shall be approved before procurement and use.) 0.0 0.0 0.0 0.0 0.0 Ground Floor 0.0 Rmt 665.2 0.0 0.0 0.0 0.0 Vetrified industrial floor Tile of premium grade having thickness 15mm to 16mm confirming to IS 4457 of size 600mmx600mm of approved make, quality and colour without any warpage laid over an under layer of 20 mm thick base of cement mortar (1:4) (1 cement: 4 coarse sand) including cutting to size, laying and filling the joints with white cement slurry mixed with colouring pigment to match the shade and colour, cleaning the surfaces with oxlaic acid, machine grinding, mirror polishing including the cost of all materials, cost of all labour, conveyance, royalties, loading, unloading, sundries, watering and curing, T&P, etc. complete as per the direction of the Engineer-in-Charge.(Note- Sample of tiles shall be approved before procurement and use.) (Make:Somany/Jhonson/RAK/kajaria) 0.0 0.0 0.0 0.0 0.0 Ground Floor 0.0 Sqm 2010.1 0.0 0.0 0.0 0.0 Finishing with Epoxy paint (Two or more coats) on steel work at all locations prepared and applied as per manufacturer's ecifications including appropriate priming coat (Red Oxide Zinc Chromate) , preparation of surface, etc. complete as per Direction of E.I.C. 0.0 0.0 0.0 0.0 Ground Floor 0.0 Sqm 272.4 0.0 0.0 0.0 0.0 Pressed Steel Doors With Vision PanelSupply installation of pressed steel doors of the specified dimensions and accessories such as hinges,door,stopper,tower bolt,door handle,door closer,dead lock,consedaled flush bolt,shaft lock,martise lock and vision panel etc.complete as mentioned along with warranty coverrage and after sales service etc.inclusive of all costs,delivery charge,fixing,fitting and any other invidental charges etc.complete excluding GST1. Hinges 2. Tower bolt 3. Door Stopper 4. Mortise Lock 5. Buffer (Make: Tata pravesh,Shaktihormann ETC) 0.0 0.0 0.0 0.0 0.0 Ground Floor 0.0 0.0 0.0 0.0 0.0 General Steeldoor Set 1000X2100 mm Single leaf door with vision panel 0.0 Each 22968.7 0.0 0.0 0.0 0.0 General Steeldoor Set 2,000.00X2,400.00 mm Double leaf door with vision panel 0.0 Each 41558.5 0.0 0.0 0.0 0.0 0.0 0.0 0.0 Providing gola 75x75 mm in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 stone aggregate 10 mm and down gauge), including finishing with cement mortar 1:3 (1 cement : 3 fine sand) as per standard design. 0.0 Rmt 258.60169491525426 0.0 0.0 0.0 0.0 Supplying and fitting-fixing of Un-plasticised Poly Vinyl Chloride (UPVC) Fixed window of approved make with 6mm thick glass of approved quality complete with frame, and all fitting and fixtures etc. complete in all respect as per the direction of the Engineer-in-Charge. 0.0 Sqm 5320.0 0.0 0.0 0.0 0.0 Supplying and fitting-fixing of Un-plasticised Poly Vinyl Chloride (UPVC) Fixed Partition of approved make with 6mm thick glass of approved quality complete with frame, and all fitting and fixtures etc. complete in all respect as per the direction of the Engineer-in-Charge. 0.0 Sqm 8620.0 0.0 0.0 0.0 0.0 Supplying, fitting and fixing of 5.5mm thick hexagonal Aluminium jally in windows as single groove, double groove and tapered clip as horizontal and vertical members for fixing of aluminium jally and joiting angle confirming to standrad Aluminium sections etc. complete as directed by the Engineer-in-charge. 0.0 Sqm 1841.0 0.0 0.0 0.0 0.0 Supplying and fixing of Hospital Glow Letter Type Name Board (Acrylic) including cost of designing, material, machine cutting & labour for mounting complete in all respect as directed by the Engineer-in-Charge.(Rate Per Letter) 0.0 Nos 3750.0 0.0 0.0 0.0 0.0 |
| 53 | Providing and fixing machine moulded aluminium covering of approved pattern & design,made out of machine cut aluminium sheet and machine holed for receiving dash fastener,over expansion joints on vertical surfaces/ceiling floors, the fixing on plate in one row on one side of joint only shall be done with stainless steel dash fasteners of 8 mm dia and 75 mm long bolt including providing aluminium washers 2 mm thick & 15 mm dia , at a staggered pitch of 200mm centre to centre including drilling holes in the receiving surface and providing expandable plastic sleeves in holes etc. complete as per direction of Engineer-in-charge. DAR-AW-Item No. 21.7-2023 Anodised aluminium sheet 2.5mm thick (anodised transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC 15) DAR-AW-Item No. 21.7.1-2023 G.R.C. JALI -Providing and fixing Glass Reinforced Concrete (GR.C) Screens in approved size pattern, design, shadeand thickness of 50mm on frame and design element in 30mm thick have weight approximately between 3.5 4 Kg per Sq Ft and color of M/S UniStone make or equivalent. The above weight and thickness is considering dimensions of screens up to 2133mm in height and 1219mm in width and having at least 50% void space. The screens should be made from '53 grade' White Portland Cement manufactured by JK Cement' or equivalent, Quartz, Fine Silica Sand, Alkali Resistant Glass Fiber manufactured by 'N.E.G JAPAN or equivalent, Super Plasticizers manufactured by \\"BASF or equivalent Polymers manufactured by 'BASF or equivalent and UV resistant Synthetic inorganic pigments should be used for pigmentation manufactured by 'BAYFERROX (Germany) or equivalent. The material casting should take place in FRP Molds. The fixing of Screens should be 'Dry fixing' Le to be done with M.S Galvanized Clamps, fixtures and fasteners of Hilti / Fischer. complete in all respect as per specification & direction of the Engineer-in-Charge. 0.0 Sqm 5928.7 0.0 0.0 0.0 0.0 Gypsum Board False Ceiling - Providing fitting and fixing of gypsum board false ceilling with aluminium anodised T Section No. 3215 with 2'-0\\" center to center, L section No. 1705 upto 15 micron on 4 walls to be fixed by means of steel screw and P.V.C plug and the Aluminium grid 2'-0\\"x2'-0\\" suspended from ceiling etc complete in all respect as per specification & direction of the Engineer-in-Charge. 0.0 Sqm 3017.1 0.0 0.0 0.0 0.0 Providing and fixing false ceiling with Trio/Hexa/Quadra UPVC Soffit Panels of approved make, shade, and finish, manufactured from high-quality virgin uPVC, suitable for interior use and resistant to moisture, termites, rot, and corrosion, including all materials and labour. The panels shall be fixed on a G.I. framework comprising galvanized iron channels, runners, supports, clamps, screws, anchors, and fasteners of adequate gauge, properly aligned, leveled, and securely fixed to the wall/structure. The work shall include supply of panels, G.I. components, trims, corner and edge profiles, joint covers, sealants, cutting, fixing, finishing, scaffolding, tools, and workmanship, ensuring neat joints and a uniform finish, complete in all respects as per manufacturer’s specifications and directions of the Engineer-in-Charge. 0.0 Sqm 4778.3 0.0 0.0 0.0 0.0 Providing and fixing wall panelling using Quadra /Hexa uPVC soffit panels of approved make, shade, and finish, manufactured from high-quality virgin uPVC, suitable for interior use and resistant to moisture, termites, rot, and corrosion, including all materials and labour. The panels shall be fixed on a G.I. framework comprising galvanized iron channels, runners, supports, clamps, screws, anchors, and fasteners of adequate gauge, properly aligned, leveled, and securely fixed to the wall/structure. The work shall include supply of panels, G.I. components, trims, corner and edge profiles, joint covers, sealants, cutting, fixing, finishing, scaffolding, tools, and workmanship, ensuring neat joints and a uniform finish, complete in all respects as per manufacturer’s specifications and directions of the Engineer-in-Charge. 0.0 Sqm 4724.2 0.0 0.0 0.0 0.0 Supply and fixing WPC Louvre of 2440 x 190 x 24mm having 55% wood powder and 30% HDPE: density of 1.425gm/ cm3: tensile strength of 29Mpa: modulous elasticity of 3500 Mpa: coefficient of thermal expansion 6 x 10-5 1/K and having anti-termite properties to be fixed with 25mm x 50mm x 1mm aluminum hollow section on the back of the Louvre with a greed work of 400mm gapcenter to center with all Labor, material, wastage, etc – all complete at site and directions of the Engineer-in-Charge. 0.0 Sqm 7164.1 0.0 0.0 0.0 0.0 Supplying , fitting and fixing of grid mineral fibre ceiling board having size 600 mm x 600 mm x 16mm of approved design and quality complete with frame and all fitting and fixtures. 0.0 0.0 1604.0 0.0 0.0 0.0 0.0 Providing, fitting and fixing of Sikadur Combiflex SG 20P 200 and sealed by Sikadur 31C @ 1.4kg per meter over the expansion joints after cleaning the joints and applying of Sikadur 32 @ 200 gms per meter Epoxy bonding agent and levelled by Sikagrout 214 @ 8kg per meter and covered with 300mm wide 16 gauge Aluminium sheet complete including cost, conveyance, taxes of all materials, labour, transportation charges etc as per specification and direction of the Engineer-in-charge. 0.0 0.0 0.0 0.0 0.0 Providing & fixing G.C.I. Sheet in roof including fixing of ridges wind ties etc. complete but excluding cost of fitting including drilling holes in wind ties etc. complete as per the direction of the Engineer-in-Charge.(Note- Sample shall be approved before procurement and use.) 0.0 Sqm 641.5 0.0 0.0 0.0 0.0 BWP 710 Grade Plywood & Mica Work - Making and fixing plywood work as per drawing and specification (main Str./body 18-19mm, doors 12-15mm, back panel 6-9mm thickness) with mica finishing for cupboard/racks/shelves/wardrobe with all necessary accessories i.e. metal handles, hinges, clamps, locks and screws etc. of approved quality including cost of all materials, labour & T&P etc complete as per direction of the Engineer-in-charge. 0.0 Sqm 11110.7 0.0 0.0 0.0 0.0 Ply Board & Mica Work :- Ply work with mica Finishing including cost of all materials, labour & T&P etc complete as per direction of the Engineer-in-charge. 0.0 Sqm 5456.0 0.0 0.0 0.0 0.0 Providing and applying two coats Unitile’s ‘Rodeo’ make or ‘Asian Paints’ in approved shade on a smooth cement sand plaster. The composition of the texture paint should consist of Acrylic Copolymer Resigns combined with Quartz, Silica, mineral aggregates, synthetic inorganic pigments, bactericide, fungicides and various other additives, giving the product water repellent properties. The first coat to be applied by brush or wool roller as a base coat, diluted with sufficient water and the final coat (Undiluted) to be applied by trowel and finished with acrylic trowel to obtain specified grooves. The thickness of both coats should be 1.0 to 1.5mm. The water repellence of the product is 86 gm/m2 as per test method IS: 5410 ‐1969. required for the work all complete as per direction of Engineer-in-charge. 0.0 Sqm 1159.2 0.0 0.0 0.0 0.0 Providing and executing mural painting work on the specified wall surface using high-quality, weather-resistant acrylic/emulsion paints of approved make and shade, including surface preparation by cleaning, scraping, minor crack filling, smoothing, and application of primer as required. The mural artwork shall be concept-based, aesthetically appealing, and executed by skilled artists as per approved design, theme, color scheme, and drawings, ensuring uniform finish, sharp detailing, and long-lasting color fastness. The work shall include all materials, labour, scaffolding, tools, protection of surrounding areas, and finishing complete in all respects as directed by the Engineer-in-Charge. 0.0 Sqm 1568.0 0.0 0.0 0.0 0.0 Heavy Duty Rope Clothesline Ideal for Drying Heavy Clothes 4 mm Thickness Nylon ClotheslineWhite. 0.0 Sqm 29.0 0.0 0.0 0.0 0.0 Supplying and fixing of Hospital Glow Letter Type Name Board (Acrylic) mentioning \\"VASTALYA SADAN \\" size as per specification including cost of designing, material, machine cutting & labour for mounting complete in all respect as directed by the Engineer-in-Charge. 0.0 Job 70000.0 0.0 0.0 0.0 0.0 Supplying and fixing of Hospital Glow Letter Type Name Board (Acrylic) mentioning \\"REGISTRATION COUNTER\\" size as per specification including cost of designing, material, machine cutting & labour for mounting complete in all respect as directed by the Engineer-in-Charge. 0.0 Job 75000.0 0.0 0.0 0.0 0.0 Supplying and fixing Rain Water Harvesting System including gutters, pipes, filters, and storage tanks, machinaries, as well as installation charges etc complete as directed by the Engineer-in-charge. 0.0 Job 50000.0 0.0 0.0 0.0 0.0 Supplying Master Layout Map in vinyl printing cum pasting colored pictures, text and symbols including fixing, installing and transportation complete as per the direction of the Engineer-in-charge. 0.0 Sqm 1650.0 0.0 0.0 0.0 0.0 Providing and supplying aluminium extruded tubular and other aluminium sections as per the architectural drawings and approved shop drawings , the aluminium quality as per grade 6063 T5 or T6 as per BS 1474,including super durable powder coating of 60-80 microns conforming to AAMA 2604 of required colour and shade as approved by the Engineer-in-Charge. (The item includes cost of material such as cleats, sleeves, screws etc. necessary for fabrication of extruded aluminium frame work. Nothing extra shall be paid on this account). 0.0 Kg 338.25 0.0 0.0 0.0 0.0 Designing, fabricating, testing, protection, installing and fixing in position semi (grid) unitized system of structural glazing (with open joints) for linear as well as curvilinear portions of the building for all heights and all levels, including:(a) Structural analysis & design and preparation of shop drawings for the specified design loads conforming to IS 875 part III (the system must passed the proof test at 1.5 times design wind pressure without any failure), including functional design of the aluminum sections for fixing glazing panels of various thicknesses, aluminium cleats, sleeves and splice plates etc. gaskets, screws, toggles, nuts, bolts, clamps etc., structural and weather silicone sealants, flashings, fire stop (barrier)-cum-smoke seals, microwave cured EPDM gaskets for water tightness, pressure equalisation & drainage and protection against fire hazard including:(b) Fabricating and supplying serrated M.S. hot dip galvanised / Aluminium alloy of 6005 T5 brackets of required sizes, sections and profiles etc. to accommodate 3 Dimentional movement for achieving perfect verticality and fixing structural glazing system rigidly to the RCC/ masonry/structural steel framework of building structure using stainless steel anchor fasteners/ bolts, nylon seperator to prevent bimetallic contacts with nuts and washers etc. of stainless steel grade 316, of the required capacity and in required numbers.(c) Providing and filling, two part pump filled, structural silicone sealant and one part weather silicone sealant compatible with the structural silicone sealant of required bite size in a clean and controlled factory / work shop environment, including double sided spacer tape, setting blocks and backer rod, all of approved grade, brand and manufacture, as per the approved sealant design, within and all around the perimeter for holding glass.(d) Providing and fixing in position flashings of solid aluminium sheet 1 mm thick and of sizes, shapes and profiles, as required as per the site conditions, to seal the gap between the building structure and all its interfaces with curtain glazing to make it watertight. 0.0 Sqm 2866.1 0.0 0.0 0.0 0.0 Extra for openable side / top hung vision glass panels (IGUs) including providing and supplying at site all accessories and hardwares for the openable panels as specified and of the approved make such as heavy duty stainless steel friction hinges, min 4 -point cremone locking sets with stainless steel plates, handles, buffers etc. including necessary stainless steel screws/ fasteners, nuts, bolts, washers etc. all complete as per the Architectural drawings, as per the approved shop drawings, as specified and as directed by the Engineer- in-Charge. 0.0 Sqm 2997.6 0.0 0.0 0.0 0.0 Providing, assembling and supplying vision glass panels (IGUs) comprising of hermetically-sealed 6-12- 6 mm insulated glass (double glazed) vision panel units of size and shape as required and specified, comprising of an outer heat strengthened float glass 6mm thick hard coated low emmissivity glass, of approved colour and shade with reflective soft coating on surface # 2 of approved colour and shade, an inner Heat strengthned clear float glass 6mm thick, spacer tube 12mm wide, dessicants, including primary seal and secondary seal (structural silicone sealant) etc.all complete for the required performances, as per the Architectural drawings, as per the approved shop drawings, as specified and as directed by the Engineer-in-Charge. The IGUs shall be assembled in the factory/ workshop of the glass processor.“(Payment for fixing of IGU Panels in the curtain glazing is included in cost of item No.26.2)“For payment, only the actual area of glass on face # 1 of the glass panels (excluding the areas of the grooves and weather silicone sealant) provided and fixed in position, shall be measured in sqm.“ (i) Coloured tinted float glass 6mm thick substrate with reflective soft coating on face # 2, + 12mm Airgap + 6mm Heat Strengthened clear Glass of approved make having properties as visible Light transmittance (VLT) of 25 to 35 %, Lightreflection internal 10 to 15%, light reflection external 10 to 20 %, shading coefficient (0.25- 0.28) and U value of 3.0 to 3.3 W/m2 degree K etc. The properties of performance glass shall be decided by technical sanctioning authority as per the site requirement. 0.0 Sqm 3036.1 0.0 0.0 0.0 0.0 Providing and fixing ISI Marked insulated fire rated door confirming to IS 3614: 2021, & tested to IS17518, and shall carry a unique label with certification/test report number. The fire rating shall be for 120minutes integrity and 30minutes insulation. Material shall be galvanised steel conforming to IS 277, made out of minimum 1.2 (18 SWG) for both frame and shutter, G.I. sheet (zinc coating 120 gsm). Frame shall be 125 x 75 grooved step profile with built in rebate for fire rated smoke seal. Frame shall be mitered and field assembled. EPDM smoke seal to be provided along with frame as standard. Door shutter shall be double skin of 60mm thick step with required fire rating and insulation with vision panel. The infill material shall be high density mineral wool of minimum 120kg/sq.m3. Intumescent seal shall be provided on all around the door leaf of minimum size 15 x 1.5mm thick. All doorset shall be factory prepped for receiving appropriate hardware and provided with necessary reinforcement for hinges, locks and door closers. The door stiles should be interlocked, for pairs of doors integral astragals has to be provided on the meeting stile for both active and inactive leaf. Vision lite, minimum 5mm clear fire rated glass of size 200 x 300mm (max 0.06sq.mt) on shutter, fixing with clipon arrangement. All frame and door shutter shall be finished polyster powder coated to minimum 50microns, of approved colour as per the direction of the engineer incharge. Cost of doorset shall include following hardware and accessories as a complete assembly. SS ball bearing hinges of SS304 grade of size 100x75x3mm, 1 set Panic device for double leaf doorset and external trim with key cylinder tested as per EN1125 and CE marked. 1no Door closer per leaf with spring size of EN 3-5, as per EN1154 & CE marked,1no door door coordinator also be given in case of double leaf door. Suitable anchor fastners for fixing on different type of wall construction as per manufacturer recommendation.Once frames is installed it shall be filled with fire rated PUF. Manufacturer test certificates shall covers complete door set as a latched assembly with a valid test certificate not exceeding 5 years from the date of issue of report. for more info refer doors details drawing. Approved make : Shakti Hormann, MPP, Godrej, Promat 0.0 Sqm 23880.0 0.0 0.0 0.0 0.0 Providing and fixing of Standard Duty Hollow Metal Door Frame and Flush Door Shutter of approved make such as Shakti Hormann, conforming to IS 4351 for steel door frames and IS 2191 (Part-II) for shutters, manufactured in an ISO 9001:2015 certified facility. The door frame shall be single rebate grooved profile of size 125 x 55 mm fabricated from 1.2 mm (18 gauge) thick galvanized steel sheet confirming to IS 277, suitable for 40 mm thick shutter, with mitered corners, self-tab assembly, inbuilt groove for PVC sealing system, mortised, drilled and tapped for hardware, complete with back plate brackets, anchor fasteners for fixing in finished plastered masonry openings, filled with non-fire rated PUF and gaps sealed with silicone sealant. The door shutter shall be 40 mm thick fully flush type with tubular core chipboard infill, faced on both sides with minimum 3 mm thick calibrated pre-laminated fibre board of minimum density 850 kg/m³ in approved shade, with minimum 40 mm wide LVL rails and stiles, all edges finished with 0.8 mm thick PVC edge banding using PUR hot melt adhesive, factory pre-engineered for hardware fixing, complete with all materials, labour, transportation, fitting and fixing in position including PVC seal, approved hardware provisions and finishing in GRAINTEK texture/wood stain/powder coated finish as specified, complete in all respects as per direction of Engineer-in-Charge. 0.0 Sqm 9285.0 0.0 0.0 0.0 0.0 Providing and fixing of Sliding windows of approved make to be fabricated from roll formed sections made of pre-painted steel (base steel as per IS-513 of 0.6 mm thick \\"D\\" quality, galvanized as per IS-277 with zinc of 120 Gm/Sq.mtr) with total coated thickness of 0.55 mm Slide guide section should be made of 0.5 mm stainless steel of 430 grade. with paint specification being with primer of 5-7 microns thick and finished paint with polyster paint (Black /Pearl white/ Chocolate Brown) of 12-16 microns along with the alkyd backer at the back of 5-7 microns and the Sections for external frame bottom and top should be of 79 x 45 mm. external frame sides should be of 69 x 24 mm, guide for top and bottom should be of 69 x 26 mm (Stainless Steel). Section for shutter should be of 26 x 30 mm, Sash bar should be of 23 57mm.Accessories / gaskets are to be used as per the manufacturer's supply and specification like gasket will be made of EPDM. All corner brackets for internal and external are to be made of glass filled nylon. The sections are to be cut to length joined and assembled by means of corner bracket and frames are fixed to the concrete/masonry walls by means of self expanding screws and glass to be used of 5 mm reflective with all taxes complete. 0.0 0.0 0.0 0.0 0.0 0.0 Ground Floor 0.0 Sqm 6486.1 0.0 0.0 0.0 0.0 First Floor 0.0 Sqm 9810.7 0.0 0.0 0.0 0.0 Second Floor 0.0 Sqm 9810.7 0.0 0.0 0.0 0.0 Third Floor 0.0 Sqm 9810.7 0.0 0.0 0.0 0.0 Fourth Floor 0.0 Sqm 9810.7 0.0 0.0 0.0 0.0 Fifth Floor 0.0 Sqm 9810.7 0.0 0.0 0.0 0.0 SiXth Floor 0.0 Sqm 9810.7 0.0 0.0 0.0 0.0 Add for plaster drip course/ groove in plastered surface or moulding to R.C.C. projections. 0.0 0.0 0.0 0.0 0.0 Ground Floor 0.0 Rmt 43.8 0.0 0.0 0.0 0.0 First Floor 0.0 Rmt 43.8 0.0 0.0 0.0 0.0 Second Floor 0.0 Rmt 43.8 0.0 0.0 0.0 0.0 Third Floor 0.0 Rmt 43.8 0.0 0.0 0.0 0.0 Fourth Floor 0.0 Rmt 43.8 0.0 0.0 0.0 0.0 Fifth Floor 0.0 Rmt 43.8 0.0 0.0 0.0 0.0 SiXth Floor 0.0 Rmt 43.8 0.0 0.0 0.0 0.0 |
| 54 | Providing and fixing barbed wire fencing on R.C.C. (1:2:4) fencing posts with chips 1.68M long, 13cm x 13cm at bottom and 8cm x 8cm at top and 30cm 30cm x 8 cm at base finished smooth at spacing of 2.0m c/c , fixing with G.I. barbed wire both in horizontal and in diagonal by means of staples and staining hooks and tying with G.I wire including cost of barbed wire, staples, hooks, tying wires and labour, post etc complete in all respect as per the direction of the Engineer-in-charge. |
| 55 | Supplying and fixing of Elastomeric Membrane of 200mm x 2mm size for expansion joint sealing from approved manuefacturer, fixing with epoxy adhesive of approved quality complete. |
| 56 | Supplying and fitting -fixing of Un-plasticised poly Vinyl Chloride (UPVC) (FENESTA/NCL VECCA LTD) Ventillator/Top Hung-60 Series duly manufactured using UPVC reinforced Profiles of 60mmx 55mmx2.5mm for outer frames ,75mmx60mmx2.25mm for casement window sash profile capable of mounting single glazing system,structurally reinforced with hot dip galvanised upto 50 microns of minimum thickness of 1.5 mm prefabricted and welded through fusion welding the wwindow sash shall be fitted with 6mm thick clear toughened glass of Saint-Gobain make duly fixed with EPDM weathering seal resistant accessories like clipping locking system made of aluminium 1 no per set of sashes and the system to be installed at the site using anchor fasteners,silicon rubber sealant,easy glazing/deglazing at siteetc including cost and conveyance of all accessories labour charges,materials and product confirming to ASTM D 638-14,EN-477-95 and other applicable codes and standards. Providing and fixing of 12mm thick Clear Toughened Glass Frameless Door WithDorma Premium Fittings.Dorma Premium (9111198) Unilite Package BTS 75,UL PT 10with Cover,UL PT 20 with Cover, UL US 10 Luck with Cover and PT 24,Dorma Premium(9137121) H Type Handle 450mm,12mm Clear Toughened Glass with Cutout and Hole.including the cost of all materials, hardware fittings, cost of all labour, conveyance,loading, unioading, T&P, etc, complete as per the direction of Engineer-in-Charge. 0.0 0.0 Earth Filling foundation and plinth-construction of embankment with earth approved material obtained from borrowpits, transporting to site, spreading, grading to required slope and compacting to meet requirement of table 300-2. 0.0 0.0 Cum 203.9 0.0 Supplying and fixing Rain Water Harvesting System including gutters, pipes, filters, and storage tanks, machinaries, as well as installation charges etc complete as directed by the Engineer-in-charge. 2.0 2.0 Each 50000.0 100000.0 TOTAL SUPER STRUCTURE 31439581.257994555 Total 42779464.859057054 1058094.0725 3241718.3484 37557901.49725704 Solar System 42053795.015157044 Supply Installation Testing and Commissioning of on grid Solar Photovoltaic Power Plant conforming to MNRE specifications as amended, consisting of Mono / Poly Crystalline silicon solar cells, net metering facility ,necessary protections, earthing, mounted on Aluminium / GI structure of suitable strength with following components a complete aas arequired: a) Solar Photovoltaic Module of capacity 330Wp or above, manufactured in India, conforming to IS14286 / IEC61215, IS/IEC61730-Part-1,IS/IEC61730-Part-2. Solar Photovoltaic Module conversion efficiency shall not be less than 16.5%. PV modules used in solar power plants /systems must be warranted for their output peak watt capacity, which should not be less than 90% at the end of 10 years and 80% at the end of 25 years. b) Power Conditioning Unit (PCU) of 350-800 V DC Input voltage range and 400 V AC, three phase , 4 wire, 50Hz +/- 2.5Hz, output voltage suitable to generate AC Power with efficiency not less than 97%, total harmonic distortion less than 3% and suitable for ambient temperature from 0 to 50 degree Celcious. The PCU shall adjust the voltage and frequency level to suit the Grid Voltage,frequency. c) Data Monitoring System complete with accessories.d)Fixing of Array junction box & Main junction box with IP 65 protection and termination arrangement for incoming and outgoing cable along with glands, lugsand other accessories etc. asarequired.e) Lightning and surge voltage protection. f) Connections & Interconnections by supplying & fixing required size XLPE insulated copper conductor 1.1 kV grade armoured power and control cables between solar modules, main power cable to grid supply PCU unit along with supplying & fixing of necessary channel/ conduit lugs and other accessories etc. asrequired. with all required accessories as required as per the direction of Engg-in-charge.Make-Kamal Solar/ EMMVEE/ Venus / Anchor/panasonic or equievalant reputed make & model A catogory, ISI marked as approved . The entire SOLAR system should be Replacement Warranty will be 5 years 5.0 kw 60500.0 302500.0 Total Solar 302500.0 FIRE EXTINGUISHERS Providing and Fixing ISI marked ABC stored pressure type Fire extinguisher of 6 Kgs. Capacity confirming to IS: 15683 with discharge hose, nozzle, Mono Amonium Phosphate base & ABC powder pressurised with nitrogen gas carrying handle and wall mounting bracket etc as required with 5 Years maintenace. 4.0 No 5590.0 22360.0 SAFEGUARD , INTIME , FIRESHIELD 0.0 Providing and Fixing of 4.5 Kgs. Capacity CO2 gas type ISI marked fire extinguisher (IS: 15683) fitted with high pressure 1 mtr. Long discharge hose & horn complete with refill gas, carrying handle and wall mounting bracket etc as required with 5 Years maintenace. 2.0 No 13260.0 26520.0 Providing and Fixing of of 2 kG capacity Eco Friendly, Stored pressure type filled with HFC 134 A ( clean agent fire extinguishant having Zero Ozone depletion potential ) Clean Agent Fire Extinguishers with safety seal, pressure guage, controllable discharge mechanism, helium leak detection tested and conforming to IS 15683 complete with initial charge as required with 5 Years maintenace. 2.0 No 20280.0 40560.0 Fire buckets 3 nos round bottom type enamel painted, white inside & Red out side and Letter \\"FIRE\\" in black out side and handle with mounting bracket and Fire bucket stand fabricated by MS angles with 5 Years maintenace.Make:FABRICATED 1.0 Set 7605.0 7605.0 SIGNAGES 0.0 Floor identification signage (i.e, GROUND FLOOR… ETC.,) at each stair enclosure on every floor, indicating the floor number in words, lettering size shall be 7.5cm with contrasting colour from back ground. Size shall be 15cm * 60cm. 3.0 No 975.0 2925.0 Fire Exit signage at each stair on every floor, indicating the direction of fire exit, lettering size shall be 7.5 cm with contrasting color from back ground. Size shall be 15cm x 60cm. 3.0 No 715.0 2145.0 Total Fire Etinguishers 102115.0 LANDSCAPE (a) Grass |
| 57 | Providing and fixing Neelgiri/Mexican grass turf with earthy 50mm to 60mm thickness of existing ground prepared with proper level and ramming with required tools wooden (Dhurmos) and than rolling the surface with light roller make the surface smoothen and light, watering with sprinkler and maintenance for 30 days or more till the grass establish properly as per direction of officer incharge. B. SITE PREPARATION 0.0 |
| 58 | Supplying and stacking of good earth at site including royalty and carriage upto 5 km complete (earth measured in stacks will be reduced by 20% for payment). |
| 59 | Supplying and stacking sludge at site including royalty and carriage upto 5 km complete (sludge measured in stacks will be reduced by 8% for payment). |
| 60 | Supplying and stacking at site dump manure from approved source, including carriage upto 5 km complete (manure measured in stacks will be reduced by 8% for payment) . Screened through sieve of I.S. designation 20 mm 8.333333333333332 Cum 239.6 1996.6666666666663 Screened through sieve of I.S. designation 16 mm 8.333333333333332 Cum 267.0 2224.9999999999995 Screened through sieve of I.S. designation 4.75 mm 8.333333333333332 Cum 288.9 2407.4999999999995 |
| 61 | Spreading of sludge, dump manure and/or good earth in required thickness as per direction of officer-in-charge (cost of sludge, dump manure and/ or good earth to be paid separately). |
| 62 | Mixing earth and sludge or manure in the required proportion specified or directed by the Officer-in-charge. PLANTATION 0.0 Supply & planting of the tree as per botanical name / common name & specification mentioned here under : 0.0 |
| 63 | Tree Providing and stacking of Tecoma argentea of height 120-135 cm. in big poly bag of size 25 cm as per direction of the officer-in-charge 10.0 Each 121.43100000000001 1214.3100000000002 Providing and stacking of Saraca indica (Sita Ashok) of height 105-120 cm. in big poly bags of size 25 cm as per direction of the officer-in-charge 10.0 Each 121.43100000000001 1214.3100000000002 Providing and stacking of Polyalthia pendula (Ashok Pendula) of height 180-195 cm. in gunny bag of size 30 cm as per direction of the officer-in-charge. 10.0 Each 151.793 1517.93 Providing and stacking of Plumeria alba dwarf dwarf of height 90-105 cm. with 3-4 branches and thick stem in big size HDPE bags as per direction of the officer-in-charge. 10.0 Each 1138.388 11383.88 Providing and stacking of Plumeria rubra of height 120-150 cm. with 3-4 branches and thick stem in big size HDPE bags as per direction of the officer-in-charge 10.0 Each 606.9 6069.0 Providing and stacking of Mimusops elengi (Maulsri) of height 180-195 cm., well developed with thick stem in big in big size HDPE bag as per direction of the officer-in-charge 10.0 Each 189.737 1897.37 Providing and stacking of Foxtail palm of ht. 240-270 cm bottom girth 35- 40 cm well developed in big size HDPE bags as per direction of the officer-in-charge. 10.0 Each 986.612 9866.119999999999 |
| 64 | Ground cover Providing and stacking of Duranta Golden, having ht.15 to 20 cm bushty shape with fresh and healthy leaves in 15 cm size of Earthen Pot/Plastic Pot & as per direction of the officer-in-charge 10.0 Each 30.362 303.62 Providing and stacking of Alternanthera species of height 15 cm to 20 cm, full of branches and foliage in 15 cm size of Earthen Pot/Plastic Pot & as per direction of the officer-in-charge. 10.0 Each 30.362 303.62 Providing and stacking of Daniella variegated, with 3 to 4 variegated leaves in 20 cm size of Earthen Pot/Plastic Pot & as per direction of the officer-in-charge 10.0 Each 30.362 303.62 Providing and stacking of Clerodendrum inerme having ht. 25 cm to 30 cm multi branched in 20 cm size of Earthen Pot/Plastic Pot & as per direction of the officer-in-charge 10.0 Each 15.181 151.81 |
| 65 | Shrurbs Providing and stacking of Ficus reginald well branched, bushy of height 60- 75 cm. in earthen pots of size 25 cm as per direction of the officer-in-charge. 8.0 Each 151.793 1214.344 Providing and stacking of Euphorbia caracasana (bronze colour leaves) of height 90-105 cm., bushy in big size HDPE bag as per direction of the officer-in-charge. 8.0 Each 159.375 1275.0 Providing and stacking of Chandni dwarf of height 15-20 cm., well branched in earthen pots of size 20 cm as per direction of the officer-in-charge. s per direction of the officer-in-charge. 8.0 Each 53.125 425.0 Providing and stacking of Thuja compacta of height 45-60 cm., well branched in earthen pots of size 25 cm as per direction of the officer-in-charge 8.0 Each 98.66799999999999 789.3439999999999 |
| 66 | Medicinal plant Providing and Stacking of Curry leaf of height 75-90 cm in poly bag of size 25 cm as perdirection of the officer-in-cha 10.0 Each 113.83199999999998 1138.3199999999997 Providing and Stacking of Adusha of ht. 30 cm with multi branches in Poly bag of size 20 cm. as per direction of the officer-in-charge. 10.0 Each 45.543 455.43 Providing and Stacking of Aprajita Blue well developed in poly bag of size 20 cm as per direction of the officer-in-charge 10.0 Each 45.543 455.43 Providing and Stacking of Peepli well developed in poly bag of size 20cm as per direction of the officer-in-charge. 10.0 Each 45.543 455.43 Providing and Stacking of Shivnath well developed in poly bag of size 20 cm as per direction of the officer-in-charge. 10.0 Each 60.707 607.07 Providing and Stacking of Marwa Dona of ht. 30cm with multi branches in Poly bag of size 20 cm.as per direction of the officer-in-charge 10.0 Each 45.543 455.43 Providing and Stacking of Nirgundi well developed in poly bag of size 20 cm as per direction of the officer-in-charge 10.0 Each 45.543 455.43 Providing and Stacking of Ficus panda plant of height 90 -105 cm. multibranches, well developed in poly bags of size 25 cm as per direction of the officer-in-charge. 10.0 Each 242.86200000000002 2428.6200000000003 Providing and stacking of Mimusops elengi (Maulsri) of height 180-195 cm., well developed with thick stem in big in big size HDPE bag as per direction of the officer-in-charge 10.0 Each 237.17125 2371.7124999999996 Ornamental 0.0 Providing and Displaying Travelers palm well developed with fresh & healthy foliage 120 to 150 cm ht. in 35 cm Cement Pot as per direction of the officer-in-charge. 5.0 Each 735.93 3679.6499999999996 Providing and Displaying Ficus reginold Topiary well developed with fresh & healthy 6 to 7 big ball specific size 210 to 240 cm ht in 45 cm Cement Pot as per direction of the officer-in-charge 5.0 Each 3102.5 15512.5 Providing and Displaying Mascarena palm well developed with fresh & healthy foliage leaves 150 to 180 cm ht in 35 cm Cement Pot as per direction of the officer-in-charge 5.0 Each 2800.4464285714284 14002.232142857141 Providing and Displaying Cycus cirsnallis well developed with fresh & healthy 35 to 40 lush green leaves in 40 cm Cement Pot as per direction of the officer-in-charge. 5.0 Each 2956.028 14780.14 Holes 90 cm dia, and 90 cm deep 70.0 Nos 119.6 8372.0 Holes 45 cm dia, and 45 cm deep 182.0 Nos 15.8 2875.6 |
| 67 | Nilkamal Plastic Manual-Lift Wheel Garbage Dustbin (Green, Blue, 60 L) Total Landscape- 549572.4393095238 All Civil, Solar, Landscape, Fire Fighting 43733652.29836658 Name of the work- Construction Of Godabarish Mishra Adarsh Prathamik Vidyalaya At UGHS Kongra, Jharigam Block, Chaklapadar(GP), Nabarangpur District (Phase-II) BILL OF QUANTITIES (CIVIL WORK) Sl.No. Description of items GROUND FLOOR TERRACE C.WALL & FENCING APP ROAD FENCING RainWater Harvesting Paver -Road Quantity Unit Rate (Rs,) Amount (Rs.) DISMANTLING WORKS Removing white or colour wash by scrapping and sand papering and preparing the surface smooth including necessary repairs to scratches etc.complete 0.0 0.0 (a) Ground Floor 0.0 Sqm 10.5 0.0 (b) First Floor 0.0 Sqm 10.5 0.0 Dismantling brick or stone masonry in lime or cement mortar above 3m. height including stacking the useful materials for reuse and removing the debris within 50m. Lead 0.0 0.0 (a) Ground Floor 0.0 Cum 1743.4812720848058 0.0 (b) First Floor 0.0 Cum 1830.7 0.0 Removing old lime or cement plaster from walls including raking out joints 12 mm deep and removing the debris within 50m lead 0.0 0.0 (a) Ground Floor 0.0 Sqm 58.9537 0.0 (b) First Floor 0.0 Sqm 61.9 0.0 (c) Second Floor 0.0 Sqm 65.0 0.0 Dismantling and removing old tiled flooring including removing the base coarse and stacking the useful materials for reuse and removing the debris within 50m lead 0.0 0.0 (a) Ground Floor 0.0 Sqm 147.3691 0.0 (b) First Floor 0.0 Sqm 154.7 0.0 Dismantling and removing old tiled cladding from walls including racking out joints 12mm deep stacking the useful materials for reuse and removing the debris within 50m lead 0.0 0.0 (a) Ground Floor 0.0 Sqm 76.63879999999999 0.0 (b) First Floor 0.0 Sqm 80.5 0.0 Dismantling and removing doors, windows and ventilators including removal of frame, hinges, fastening and stacking the same for reuse and removing the debris within 50m lead 0.0 0.0 (a) Ground Floor 0.0 Sqm 465.1353 0.0 (b) First Floor 0.0 Sqm 488.4 0.0 Dismantling and removing cement concrete including stacking the useful materials for reuse and removing the debris within 50m lead 0.0 0.0 (a) Ground Floor 0.0 Cum 877.1648 0.0 (b) First Floor 0.0 Cum 921.0 0.0 Dismantling and removing R.C.C. columns beams slab staircase landing, lintels including stacking the useful materials for reuse and removing the debris within 50m lead. 0.0 0.0 (a) Ground Floor 0.0 Cum 1731.81 0.0 (b) First Floor 0.0 Cum 1818.4 0.0 Dismantling G.C.I. or A.C. sheet roofing after carefully removing the bolts and nuts including stacking of the materials for reuse and removing the debris within 50m lead 0.0 0.0 (a) Terace Floor 0.0 Sqm 106.28 0.0 Dismantling wrought and framed timber in roof frame work of floors after careful removal of nail, bolts etc. and stacking of the materials for reuse and removing the debris within 50m lead 0.0 0.0 (a) Terace Floor 0.0 cum 1478.9531 0.0 Dismantling and removing 2.5 cm thick grading concrete from roof slab cleaning the surface lowering and removing the debris within 50m lead 0.0 0.0 (a) Ground Floor 0.0 Sqm 132.6332 0.0 (b) First Floor 0.0 Sqm 139.3 0.0 (a) Terace Floor 0.0 Sqm 146.2 0.0 Disposal of moorum/building rubbish/ malba/ similar unserviceable, dismantled or waste material by mechanical transport including loading, transporting, unloading to approved municipal dumping ground for lead upto 10 km for all lifts, complete as per directions of Engineer-in-charge. 0.0 0.0 (a) Ground Floor 0.0 Cum 330.8 0.0 (b) First Floor 0.0 Cum 330.8 0.0 (c) Second Floor 0.0 Cum 330.8 0.0 0.0 0.0 0.0 0.0 0.0 0.0 Cutting of trees, including cutting of trunks, branches and removal of stumps, roots, stacking of serviceable material with all lifts and up to a lead of 1000 metres and earth filling in the depression/pit. 0.0 0.0 Girth from 300mm to 600mm 0.0 Each 385.0 0.0 A CIVIL WORK SUB-STRUCTURE CIVIL WORK 0.0 Clearing and grubbing roads and land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300 mm, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, up to a lead of 1000 metres including removal and disposal of top organic soil not exceeding 150 mm in thickness. 10.58 10.58 Sqm 8.63 91.3054 EARTH WORK |
| 68 | Excavation, loading, unloading and carriage by mechanical means of all kinds of soil, including stoney earth, gravel and moorum etc interspread with boulders upto 1/2 cum size with all lifts and delifts including trimming of slopes and bed to design section and depositing the the excavated materials away from work site as per the specification and as directed by the Engineer- in-charge within an initial lead of 1km from the place of excavation complete. 1732.49 142.2 32.24 50.0 1891.63 Cum 146.7 277502.121 20860.739999999998 0.0 254156.283 Earth work in excavation in foundation trenches, column foundation, pit, etc in all kind of soil including moorum stony earth and earth mixed with boulders except sheet rock and boulders not requiring blasting including dressing of sides and levelling the bed up to the required depth and depositing the excavated materials away from the work site with initial lead of 50 mtr and all lifts, including shoring, shuttering & dewatering (if required) with cost of labour, labour cess, hire & running charges of all machineries, sundries & T&P required for the work complete as directed by the Engineer in charge. 0.0 0.0 0.0 0.0 0.0 Upto 1.5mtr Depth 0.0 Cum 282.9 0.0 0.0 0.0 0.0 From 1.5mtr Depth to 3.0mtr Depth 0.0 Cum 305.36 0.0 0.0 0.0 0.0 |
| 69 | Filling the Plinth with excavated materials (excluding rock), in layers not exceeding 0.225 m in depth including cost of watering, ramming, dressing and levelling the top to proper level & gradient, cost of labour, conveyance, loading, unloading, T&P, etc, all complete as per the direction of Engineer-in-Charge. 1154.99 94.8 1249.79 Cum 157.2 196466.98799999998 14902.559999999998 0.0 181564.42799999999 |
| 70 | Filling the Foundation, Sides of Foundation, etc. in mechanical means with excavated materials (excluding rock), in layers not exceeding 0.225 m in depth including cost of watering, ramming, dressing and levelling the top to proper level & gradient, cost of machinary, conveyance, loading, unloading, T&P, etc, all complete as per the direction of Engineer-in-Charge. 0.0 0.0 Cum 146.7 0.0 0.0 0.0 0.0 Disposal of surplus/ excavated materials by mechanical means within 5km. Lead away from the site including cost of all labour , T&P complete as per the direction of the Engineer-in-charge. 0.0 0.0 0.0 0.0 0.0 (a)Ground Floor 0.0 Cum 278.8 0.0 0.0 0.0 0.0 |
| 71 | Supplying, diluting and preparing chemical emulsion like Imidacloprid 30.5 % SC or other chemicals approved by Central Insecticides Board or as directed by the manufacturer and spraying the mixture uniformly by sprayer as Pre/Post-Constructional Anti-termite Treatment confirming to IS 6313 (Part-II) including the cost of all materials, cost of all labour, conveyance, loading, unloading, T&P, etc. all complete as per the direction of Engineer-in-Charge. 1818.06 1818.06 sqm 104.5 189987.27 0.0 0.0 189987.27 |
| 72 | Supplying and Filling with Sand in Foundation and Plinth in layers not exceeding 20 cm in depth, well watered and compact , top surface dressed and levelled to proper level and gradient including cost of all materials , conveyance, royalties, loading, unloading, cost of all labour, T&P, etc.All compelete as per the dirrection of Engineer-in-charge. 1045.4785000000002 11.79 3.18 30.0 1090.4485000000002 Cum 817.6 891550.6936000002 9639.503999999999 0.0 854783.2216000002 |
| 73 | Providing and lying Plain Cement Concrete of proportion (1:3:6) in foundation & floor using 40 mm & down grade black hard crusher broken granite stone metal, washed and screened sharp sand of approved quality from approved quarry including hoisting, lowering, laying the concrete, ramming, watering and curing etc. complete to required thickness including cost of all materials, conveyance, loading, unloading, royalties, cost of labours, T&P, hire & running charges of concrete mixer, etc. all complete as per the direction of the Engineer -in -charge. 327.74 11.79 339.53000000000003 Cum 6220.7 2112114.271 73342.05299999999 0.0 2038772.218 Depth 1.5 to 4.5mtr lvl 0.0 Cum 6559.4 0.0 0.0 0.0 0.0 |
| 74 | Providing and lying Plain Cement Concrete of proportion (1:4:8) in foundation & floor using 40 mm & down grade black hard crusher broken granite stone metal, washed and screened sharp sand of approved quality from approved quarry including hoisting, lowering, laying the concrete, ramming, watering and curing etc. complete to required thickness including cost of all materials, conveyance, loading, unloading, royalties, taxes, cost of labours, T&P, hire & running charges of concrete mixer, etc. all complete as per the direction of the Engineer -in -charge. Ground Floor 30.0 30.0 Cum 5826.3 174789.0 0.0 0.0 0.0 Depth 1.5 to 4.5mtr lvl 1.28 1.28 Cum 6164.9 7891.072 0.0 0.0 0.0 |
| 75 | Providing and laying in position of plain cement concrete 1:2:4 (1 Cement :2 Sand :4 Coarse Agreegate) in floors using 12mm size hard broken crusher broken granite stone metal, washed and screened sharp sand of approved quality from approved quarry including hoisting, lowering, laying the concrete, ramming, watering and curing etc. complete to required thickness including cost of all materials, conveyance, loading, unloading, royalties, cost of labours, T&P, hire & running charges of concrete mixer, etc. all complete as per the direction of the Engineer -in -charge. Ground Floor 13.089374999999999 13.089374999999999 Cum 7841.5 102640.33406249998 0.0 0.0 102640.33406249998 RCC WORK 0.0 0.0 0.0 0.0 Providing, lifting, hoisting and laying in position machine batched , machine mixed and machine vibrated design mix cement concrete of M-25(minimum cement content not less than 403 Kg/Cum) grade in reinforced cement concrete structural elements using black hard crusher broken granite chips of approved quality from approved quarry including mixing and compacting to proper shape and size, level and plumbs and finishing the exposed surfaces smooth including the cost of all materials, cost of labour, conveyance,loading, unloading, royalties, watering and curing for the required period, T&P , hire & running charges of concrete mixer and vibrator, cost of Admixtures in recommended proportions ( as per IS 9103 ) to accelerate, retard setting of concrete, improve workability without impairing strength and durability etc. complete as per the direction of the Engineer-in-charge but excluding the cost of steel reinforcement & centring shuttering. 0.0 0.0 0.0 0.0 0.0 Ground Floor 0.0 Cum 6685.3 0.0 0.0 0.0 0.0 First Floor 0.0 Cum 6810.1 0.0 0.0 0.0 0.0 |
| 76 | Providing, lifting, hoisting and laying in position machine batched , machine mixed and machine vibrated design mix cement concrete of M-25 Including the cost of Centering and Shuttering (minimum cement content not less than 403 Kg/Cum) grade in reinforced cement concrete structural elements using black hard crusher broken granite chips of approved quality from approved quarry including mixing and compacting to proper shape and size, level and plumbs and finishing the exposed surfaces smooth including the cost of all materials, cost of labour, conveyance,loading, unloading, royalties, watering and curing for the required period, T&P , hire & running charges of concrete mixer and vibrator, cost of Admixtures in recommended proportions ( as per IS 9103 ) to accelerate, retard setting of concrete, improve workability without impairing strength and durability etc. complete as per the direction of the Engineer-in-charge but excluding the cost of steel reinforcement. (A)R.C.C. foundation and footing bases of columns mass concrete pre-cast slab etc. 0.0 0.0 0.0 0.0 (a)Ground Floor 355.45 12.0 367.45 Cum 7060.1 2594233.745 84721.20000000001 0.0 2509512.545 (B)R.C.C. Column uto plinth 0.0 0.0 0.0 0.0 Ground Floor 28.03 1.91 29.94 Cum 16442.9 492300.42600000004 31405.939000000002 0.0 460894.4870000001 |
| 77 | Providing & fixing TOR Fe-500 HYSD Reinforcement bars of required diameter and approved quality for Reinforced Cement Concrete work including straightening, cutting, bending, binding, welding(if approved) , joining (if necessary), tying the grills, hoisting, lowering and placing in position as per the approved design & drawings (BBS) with provision of standard fan hooks including the cost of all materials, cost of all labour, conveyance, loading, unloading, cost of binding wires of 18 to 20 gauge, T&P, etc, all complete as per the direction of Engineer-in-Charge.Note: (Linear measurements will be taken & quantity will be calculated on standard weight. Lap length of bars & Weight of binding wire will not be considered for measurement and payment). 0.0 0.0 0.0 GROUND FLOOR SUB STRUCTURE 332.01 13.04 345.05 Qntl 9294.3 3206998.215 121197.67199999998 0.0 3085800.5429999996 0.0 0.0 0.0 MASSONARY WORKS 0.0 0.0 0.0 0.0 |
| 78 | Providing and laying Brick Masonry work in Foundation & Plinth using Fly ash bricks of 25 Cm. x 12 Cm. x 8 Cm. size having crushing strength not less than 75 Kg./Cm2 with dimensional tolerance + 2 % confirming to IS 12894 and IS 2212 in cement mortar (1:6) affter immersing the bricks for minimum 6 hours in water before use, with all necessary projections, splays cutting, circular moulding, corbelling, etc. as per the drawings including the cost of all materials, cost of all labour, conveyance, royalties, loading, unloading, scaffolding, staging, watering and curing, sundries, T&P, etc. complete as per the direction of the Engineer-in-charge. (a)Ground Floor 125.31 13.27 13.22 151.8 Cum 5815.7 882823.26 77174.33899999999 0.0 728765.367 0.0 0.0 0.0 |
| 79 | Supplying and fixing of 80mm thick cement concrete interlocking paver block of M-40 grade of approved make, design, colour and size made by Block making machine with proper compaction laid in required pattern etc. complete in all respect conforming to IRC SP - 63:2018. |
| 80 | Supplying and fixing of Pre cast kerb stone of size 300mm x 300mm x 150mm of M-30 grade of approved make, design, colour and size made by Block making machine with proper compaction fixed in required pattern etc. complete in all respect conforming to IS 5758:1984. |
| 81 | Painting two coats of synthetic enamel paint on road work over Plaster or RCC Works like (kerb wall,bridge rcc barrier) as per approved shade of approved quality , sand papering, polishing the surface including cost, conveyance,labour, T&P, scaffolding etc. as required for the work complete as per direction of Engineer-in-charge. (The paints are to be approved before procurement and use) KERB PAINTING 48.6 48.6 Sqm 84.5 4106.7 0.0 0.0 0.0 0.0 0.0 0.0 TOTAL 11313859.561062498 0.0 0.0 0.0 0.0 0.0 0.0 SUPER-STRUCTURE 0.0 0.0 0.0 RCC WORK 0.0 0.0 0.0 |
| 82 | Providing, lifting, hoisting and laying in position machine batched , machine mixed and machine vibrated design mix cement concrete of M-25 Including the cost of Centering and Shuttering (minimum cement content not less than 403 Kg/Cum) grade in reinforced cement concrete structural elements using black hard crusher broken granite chips of approved quality from approved quarry including mixing and compacting to proper shape and size, level and plumbs and finishing the exposed surfaces smooth including the cost of all materials, cost of labour, conveyance,loading, unloading, royalties, watering and curing for the required period, T&P , hire & running charges of concrete mixer and vibrator, cost of Admixtures in recommended proportions ( as per IS 9103 ) to accelerate, retard setting of concrete, improve workability without impairing strength and durability etc. complete as per the direction of the Engineer-in-charge but excluding the cost of steel reinforcement. a R.C.C. Plinth Beam 0.0 0.0 0.0 0.0 (a)Ground Floor 102.43 6.68 1.0 110.11000000000001 Cum 7934.5 873667.7950000002 53002.46 0.0 812730.8350000001 b (B)R.C.C. Column & Roof Beam 0.0 0.0 0.0 0.0 Ground Floor 192.67000000000002 1.75 194.42000000000002 Cum 16442.9 3196828.6180000007 28775.075000000004 0.0 3168053.5430000005 Terrace 12.91 12.91 Cum 18519.2 239082.872 0.0 239082.872 0.0 Second Floor 0.0 Cum 21004.6 0.0 0.0 0.0 0.0 Third Floor 0.0 Cum 23979.8 0.0 0.0 0.0 0.0 Fourth Floor 0.0 Cum 27541.8 0.0 0.0 0.0 0.0 Fifth Floor 0.0 Cum 31806.8 0.0 0.0 0.0 0.0 SiXth Floor 0.0 Cum 36913.8 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 c (C) R.C.C. Slab & RCC Chajja 0.0 0.0 0.0 0.0 Ground Floor 269.96999999999997 0.44 270.40999999999997 Cum 12838.9 3471766.9489999996 5649.116 0.0 3466117.8329999996 Terrace 19.290000000000003 19.290000000000003 Cum 14194.4 273809.976 0.0 273809.976 0.0 Second Floor 0.0 Cum 15814.9 0.0 0.0 0.0 0.0 Third Floor 0.0 Cum 17752.2 0.0 0.0 0.0 0.0 Fourth Floor 0.0 Cum 20068.7 0.0 0.0 0.0 0.0 Fifth Floor 0.0 Cum 22839.0 0.0 0.0 0.0 0.0 SiXth Floor 0.0 Cum 26152.5 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 d (D)R.C.C. Staircase 0.0 0.0 0.0 0.0 Ground Floor 9.78 9.78 Cum 16305.1 159463.878 0.0 0.0 159463.878 Terrace 0.0 Cum 18353.9 0.0 0.0 0.0 0.0 Second Floor 0.0 Cum 20806.2 0.0 0.0 0.0 0.0 Third Floor 0.0 Cum 23741.8 0.0 0.0 0.0 0.0 Fourth Floor 0.0 Cum 27256.3 0.0 0.0 0.0 0.0 Fifth Floor 0.0 Cum 31464.1 0.0 0.0 0.0 0.0 SiXth Floor 0.0 Cum 36502.6 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 e (E)R.C.C. lintel 0.0 0.0 0.0 0.0 Ground Floor 34.64 34.64 Cum 14773.8 511764.432 0.0 0.0 511764.432 Terrace 0.58 0.58 Cum 16516.4 9579.512 0.0 9579.512 0.0 Second Floor 0.0 Cum 18601.2 0.0 0.0 0.0 0.0 Third Floor 0.0 Cum 21095.9 0.0 0.0 0.0 0.0 Fourth Floor 0.0 Cum 24081.2 0.0 0.0 0.0 0.0 Fifth Floor 0.0 Cum 27654.1 0.0 0.0 0.0 0.0 SiXth Floor 0.0 Cum 31930.5 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 f (F)R.C.C. Fins 0.0 0.0 0.0 0.0 Ground Floor 1.66 1.66 Cum 12123.1 20124.346 0.0 0.0 20124.346 First Floor 0.0 Cum 13335.5 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 R.C.C. Grade Slab 0.0 0.0 0.0 0.0 0.0 Ground Floor 0.0 Cum 7060.1 0.0 0.0 0.0 0.0 Double under reamed pile foundation with R.C.C. M25 using 12mm size black hard granite (crusher broken)stone chips including cost of boreholes but excluding cost of M.S. rod/Tor steel and labour chrages for cutting, bending and binding of steel. 0.0 0.0 0.0 0.0 0.0 450mm Dia & 6.00Mtr Long Per One Pile 0.0 Nos 16667.33 0.0 0.0 0.0 0.0 For Each Addl. Depth of 0.50Mtr Beyond Initial Depth of 6.0Mtr add Extra to Rate 0.0 Nos 793.57 0.0 0.0 0.0 0.0 |
| 83 | Providing and lying plain cement concrete of proportion (1:6:12) in false column with 40 mm. Size black hard crusher broken granite stone metal and screened and washed sharp sand for mortar of approved quality from approved quarry, washed and cleaned including hoisting, lowering, laying concrete, ramming, watering and curing etc. complete to required levels laid in layers not exceeding 15 cm thick in each layer including cost, conveyance, loading, unloading, royalties and taxes all materials and cost all labours, sundries, T & P required for the work including shoring, shuttering and dewatering if required including hire & running charges of water pump complete as per the instruction of the Engineer-in-Charge. |
| 84 | Providing & fixing TOR Fe-500 HYSD Reinforcement bars of required diameter and approved quality for Reinforced Cement Concrete work including straightening, cutting, bending, binding, welding(if approved) , joining (if necessary), tying the grills, hoisting, lowering and placing in position as per the approved design & drawings (BBS) with provision of standard fan hooks including the cost of all materials, cost of all labour, conveyance, loading, unloading, cost of binding wires of 18 to 20 gauge, T&P, etc, all complete as per the direction of Engineer-in-Charge.Note: (Linear measurements will be taken & quantity will be calculated on standard weight. Lap length of bars & Weight of binding wire will not be considered for measurement and payment). Ground Floor 783.13 12.9 1.1 797.13 Qntl 9294.3 7408765.358999999 119896.47 0.0 7278645.158999999 Terrace 56.23 56.23 Qntl 9328.38 524534.8073999999 0.0 524534.8073999999 0.0 Second Floor 0.0 Qntl 9364.18 0.0 0.0 0.0 0.0 Third Floor 0.0 Qntl 9401.8 0.0 0.0 0.0 0.0 Fourth Floor 0.0 Qntl 9441.3 0.0 0.0 0.0 0.0 Fifth Floor 0.0 Qntl 9482.7 0.0 0.0 0.0 0.0 SiXth Floor 0.0 Qntl 9526.2 0.0 0.0 0.0 0.0 0.0 0.0 0.0 MASSONARY WORKS 0.0 0.0 0.0 |
| 85 | Providing and laying Brick masonry work in Superstructure using Fly ash bricks of 25 Cm. x 12 Cm. x 8 Cm. size having crushing strength not less than 75 Kg./Cm2 with dimensional tolerance + 2 % confirming to IS 12894 and IS 2212 in cement mortar (1:4) for Half Brick Masonry Wall with provisions for 2 nos 6mm dia MS bar at each 4th layer after immersing the bricks for minimum 6 hours in water before use, with all necessary projections, splays cutting, circular moulding, corbelling, etc. as per the drawings including the cost of all materials, cost of all labour, conveyance, royalties, loading, unloading, scaffolding, staging, watering and curing, sundries, T&P, etc. complete as per the direction of the Engineer-in-charge. ( Excluding Cost Of Steel Reinforcement ). Ground Floor 20.37 20.37 Cum 6072.7 123700.899 0.0 0.0 123700.899 Terrace 0.0 Cum 6458.6 0.0 0.0 0.0 0.0 Second Floor 0.0 Cum 6902.5 0.0 0.0 0.0 0.0 Third Floor 0.0 Cum 7413.0 0.0 0.0 0.0 0.0 Fourth Floor 0.0 Cum 8000.0 0.0 0.0 0.0 0.0 Fifth Floor 0.0 Cum 8675.1 0.0 0.0 0.0 0.0 SiXth Floor 0.0 Cum 9451.4 0.0 0.0 0.0 0.0 |
| 86 | Providing and laying of Full Brick Masonry work in Superstructure using Fly ash bricks of 25 Cm. x 12 Cm. x 8 Cm. size having crushing strength not less than 75 Kg./Cm2 with dimensional tolerance + 2 % confirming to IS 12894 and IS 2212 in cement mortar (1:6) affter immersing the bricks for minimum 6 hours in water before use, with all necessary projections, splays cutting, circular moulding, corbelling, etc. as per the drawings including the cost of all materials, cost of all labour, conveyance, royalties, loading, unloading, scaffolding, staging, watering and curing, sundries, T&P, etc. complete as per the direction of the Engineer-in-charge. Ground Floor 452.95 20.79 473.74 Cum 5849.1 2770952.634 121602.789 0.0 2649349.845 Terrace 129.38 129.38 Cum 6235.0 806684.2999999999 0.0 806684.2999999999 0.0 Second Floor 0.0 Cum 6678.9 0.0 0.0 0.0 0.0 Third Floor 0.0 Cum 7189.4 0.0 0.0 0.0 0.0 Fourth Floor 0.0 Cum 7776.4 0.0 0.0 0.0 0.0 Fifth Floor 0.0 Cum 8451.5 0.0 0.0 0.0 0.0 SiXth Floor 0.0 Cum 9227.8 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 FINISHING WORK 0.0 0.0 0.0 0.0 |
| 87 | Providing 6 mm thick Cement Plaster in Cement Mortar of (1:4) to Ceilings of Roof Slabs, Stairs, Landings, Chajja, Shelves, Columns, Beams and Lofts etc. including roughening, scraping and cleaning and finishing the plastered surface smooth using wooden floats only to proper plumbs and level, making grooves, beads and drip coarse to give required ornamental finish as per drawings including cost of all materials, conveyance, loading and unloading and royalties, all labour, scaffolding, watering and curing , sundries, T&P etc. complete as per direction of the Engineer-in-charge Ground Floor 0.0 63.68 63.68 Sqm 217.2 13831.295999999998 13831.295999999998 0.0 0.0 Terrace 0.0 0.0 Sqm 222.8 0.0 0.0 0.0 0.0 Second Floor 0.0 Sqm 228.6 0.0 0.0 0.0 0.0 Third Floor 0.0 Sqm 234.5 0.0 0.0 0.0 0.0 Fourth Floor 0.0 240.6 0.0 0.0 0.0 0.0 Fifth Floor 0.0 246.9 0.0 0.0 0.0 0.0 SiXth Floor 0.0 253.4 0.0 0.0 0.0 0.0 Providing 12mm thick cement plaster in cement mortar (1:4) to the surface of half brick masonry wall including racking out joints, scraping and cleaning the surface and finishing the plaster surface smooth using wooden floats, bars, etc only to proper plumbs and level and making grooves, beads and drip coarse to give required ornamental finish as per drawings including cost of all materials, conveyance, loading and unloading, royalties, cost of all labour, scaffolding, staging, watering before plastering and curing, sundries and T&P, etc. complete as per direction of the Engineer-in-charge. 0.0 0.0 0.0 0.0 Ground Floor 0.0 Sqm 207.1 0.0 0.0 0.0 0.0 Terrace 0.0 Sqm 211.9 0.0 0.0 0.0 0.0 Second Floor 0.0 Sqm 216.8 0.0 0.0 0.0 0.0 Third Floor 0.0 Sqm 221.9 0.0 0.0 0.0 0.0 Fourth Floor 0.0 Sqm 227.1 0.0 0.0 0.0 0.0 Fifth Floor 0.0 Sqm 232.5 0.0 0.0 0.0 0.0 SiXth Floor 0.0 Sqm 238.0 0.0 0.0 0.0 0.0 |
| 88 | Providing 16mm thick cement plaster in cement mortar (1:6) to the surfaces of brick masonry wall including racking out joints, scraping and cleaning the surface and finishing the plaster surface smooth using wooden floats, bars, etc only to proper plumbs and level and making grooves, beads and drip coarse to give required ornamental finish as per drawings including cost of all materials, conveyance, loading and unloading, royalties, cost of labour, scaffolding, staging, watering before plastering and curing, sundries and T&P, etc. complete as per direction of the Engineer-in-charge.(inner side) Ground Floor 2382.24 239.25 2621.49 Sqm 280.8 736114.392 67181.40000000001 0.0 668932.992 Terrace 750.14 750.14 Sqm 287.9 215965.30599999998 0.0 215965.30599999998 0.0 Second Floor 0.0 Sqm 295.3 0.0 0.0 0.0 0.0 Third Floor 0.0 Sqm 302.8 0.0 0.0 0.0 0.0 Fourth Floor 0.0 310.6 0.0 0.0 0.0 0.0 Fifth Floor 0.0 318.7 0.0 0.0 0.0 0.0 SiXth Floor 0.0 326.9 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 |
| 89 | Providing 12mm thick cement plaster in cement mortar (1:6) to the surface of brick masonry wall including racking out joints, scraping and cleaning the surface and finishing the plaster surface smooth using wooden floats, bars, etc only to proper plumbs and level and making grooves, beads and drip coarse to give required ornamental finish as per drawings including cost of all materials, conveyance, loading and unloading,royalties, cost of labour, scaffolding, staging, watering before plastering and curing, sundries and T&P, etc. complete as per direction of the Engineer-in-charge.(Outer side) Ground Floor 3122.11 3122.11 Sqm 194.5 607250.395 0.0 0.0 607250.395 Terrace 517.53 517.53 Sqm 202.5 104799.825 0.0 104799.825 0.0 Second Floor 0.0 Sqm 210.8 0.0 0.0 0.0 0.0 Third Floor 0.0 Sqm 219.6 0.0 0.0 0.0 0.0 Fourth Floor 0.0 Sqm 228.8 0.0 0.0 0.0 0.0 Fifth Floor 0.0 Sqm 238.4 0.0 0.0 0.0 0.0 SiXth Floor 0.0 Sqm 248.6 0.0 0.0 0.0 0.0 Providing 12mm thick cement plaster in cement mortar (1:4) with neat cement punning including racking out joints, scraping and cleaning the surface and finishing the plaster surface smooth using wooden floats, bars, etc only to proper plumbs and level and making grooves, beads and drip coarse to give required ornamental finish as per drawings including cost of all materials, conveyance, loading and unloading, taxes, royalties, cost of all labour, scaffolding, staging, watering before plastering and curing, sundries and T&P, etc. complete as per direction of the Engineer-in-charge. 0.0 0.0 0.0 0.0 Ground Floor 20.24 20.24 Sqm 215.2 4355.647999999999 0.0 0.0 0.0 Extra for plastering done on moulding, cornices or architraves including neat finish to lineand level: 0.0 0.0 0.0 0.0 0.0 Ground Floor 0.0 Sqm 659.0 0.0 0.0 0.0 0.0 Terrace 0.0 Sqm 659.0 0.0 0.0 0.0 0.0 Second Floor 0.0 Sqm 659.0 0.0 0.0 0.0 0.0 Third Floor 0.0 Sqm 659.0 0.0 0.0 0.0 0.0 Fourth Floor 0.0 Sqm 659.0 0.0 0.0 0.0 0.0 Fifth Floor 0.0 Sqm 659.0 0.0 0.0 0.0 0.0 SiXth Floor 0.0 Sqm 659.0 0.0 0.0 0.0 0.0 PLINTH PROTECTION 0.0 0.0 0.0 0.0 0.0 Making plinth protection 100 mm thick using of M20 grade cement concrete necessary excavation, levelling & dressing & finishing the top smooth. 0.0 0.0 0.0 0.0 0.0 (a)Ground Floor 0.0 cum 6678.26 0.0 0.0 0.0 0.0 0.0 0.0 0.0 |
| 90 | Providing average 25mm thick grading Concrete in C.C ( 1:2:2 ) using 6mm size crusher broken black hard granite chips using 2% water proofing cement compound of approved make after scraping and cleaning the roof surface and finishing smooth to proper slope and gradient including cost of all materials, conveyance, sundries,T&P watering and curing by ponding water over terrace slab etc. complete as per the direction of the Engineer-in-charge. Terrace 1770.98 1770.98 Sqm 427.3 756739.7540000001 0.0 756739.7540000001 Second Floor 0.0 Sqm 514.2 0.0 0.0 0.0 0.0 Third Floor 0.0 Sqm 567.7 0.0 0.0 0.0 0.0 Fourth Floor 0.0 Sqm 629.2 0.0 0.0 0.0 0.0 Fifth Floor 0.0 Sqm 699.9 0.0 0.0 0.0 0.0 SiXth Floor 0.0 Sqm 781.3 0.0 0.0 0.0 0.0 Providing and Laying of 2.5 cm. Damp proof course with C.C. (1:2:4) using 12mm. Size hard broken granite Chips including cost of all materials, conveyance, loading, unloading, royalties, taxes, cost of labours, T&P, hire & running charges for all leads as per direction of the engineer-in-charge. 0.0 0.0 0.0 0.0 0.0 Ground Floor 0.0 Sqm 391.7 0.0 0.0 0.0 0.0 Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. 0.0 0.0 0.0 0.0 0.0 Ground Floor 0.0 Kg 96.2 0.0 0.0 0.0 0.0 Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. (Mild steel tubes hot finished seamless type) 0.0 0.0 0.0 0.0 0.0 Ground Floor 0.0 KG 146.82 0.0 0.0 0.0 0.0 Supplying, filling, spreading & leveling stone boulders of size range 40 mm in recharge pit of required thickness including cost of material, labour, carriage, royalty, etc complete as directed by the Engineer-in-charge. 0.0 0.0 0.0 0.0 0.0 Ground Floor 0.6749999999999997 0.6749999999999997 Cum 2261.6 1526.5799999999992 0.0 0.0 0.0 Supplying, filling, spreading & leveling stone boulders of size range 20 mm in recharge pit of required thickness including cost of material, labour, carriage, royalty, etc complete as directed by the Engineer-in-charge. 0.0 0.0 0.0 0.0 0.0 Ground Floor 0.6749999999999997 0.6749999999999997 Cum 2711.1 1829.9924999999992 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 FINISHING WORK 0.0 0.0 0.0 0.0 0.0 0.0 0.0 |
| 91 | Supplying and finishing the plastered surface of wall using 2 Coats of Cement Based Wall Putty (Water Based) of approved make and quality and finished smooth and even surface to receive the paint including the cost of all materials, cost of all labour, conveyance, taxes, loading, unloading, scaffolding, T&P, etc, all complete as per the direction of Engineer-in-Charge. Interior Wall Putty 0.0 0.0 0.0 0.0 Ground Floor 4897.23 4897.23 Sqm 88.1 431445.96299999993 0.0 0.0 431445.96299999993 Terrace 0.0 0.0 Sqm 90.0 0.0 0.0 0.0 0.0 Second Floor 0.0 Sqm 92.0 0.0 0.0 0.0 0.0 Third Floor 0.0 Sqm 94.1 0.0 0.0 0.0 0.0 Fourth Floor 0.0 Sqm 96.2 0.0 0.0 0.0 0.0 Fifth Floor 0.0 Sqm 98.4 0.0 0.0 0.0 0.0 SiXth Floor 0.0 Sqm 100.6 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 Outer Wall Putty 0.0 0.0 0.0 0.0 0.0 Ground Floor 0.0 Sqm 0.0 0.0 0.0 0.0 0.0 Terrace 0.0 Sqm 0.0 0.0 0.0 0.0 0.0 Second Floor 0.0 Sqm 0.0 0.0 0.0 0.0 0.0 Third Floor 0.0 Sqm 0.0 0.0 0.0 0.0 0.0 Fourth Floor 0.0 Sqm 0.0 0.0 0.0 0.0 0.0 Fifth Floor 0.0 Sqm 0.0 0.0 0.0 0.0 0.0 SiXth Floor 0.0 Sqm 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 |
| 92 | Providing and applying 2 coats plastic emulsion paint of approved quality and shade over a coat of wall primer of approved quality to surfaces (interior) including throughly brushing the surface free from foreign materials, sand papering smooth the intermediate coats, providing necessary putty & primer including of all materials, labour, conveyance,royalties, scaffolding, watering, curing, sundries, tools and plants etc as per the direction of Engineer-in-charge. (colour & shade to be approved before procurment & use) Ground Floor 4919.8 4919.8 Sqm 194.1 954933.18 0.0 0.0 954933.18 First Floor 847.92 847.92 Sqm 198.4 168227.328 0.0 168227.328 0.0 Second Floor 0.0 Sqm 202.81 0.0 0.0 0.0 0.0 Third Floor 0.0 Sqm 207.3 0.0 0.0 0.0 0.0 Fourth Floor 0.0 Sqm 212.0 0.0 0.0 0.0 0.0 Fifth Floor 0.0 Sqm 216.8 0.0 0.0 0.0 0.0 SiXth Floor 0.0 Sqm 221.8 0.0 0.0 0.0 0.0 |
| 93 | Providing and Painting with Two Coats Weather Coat Paint (exterior grade) of approved make & shade manufactured by reputed manufacturer make an even finished surface over a coat of water bound cement primer in all heights with all scaffolding and staging charges including cost, conveyance, cost of all labours, T & P, sundries etc. as required for the work complete. Ground Floor 2473.17 302.93 2776.1 Sqm 186.2 516909.81999999995 56405.566 0.0 460504.25399999996 First Floor 532.8 532.8 Sqm 193.3 102990.23999999999 0.0 102990.23999999999 0.0 Second Floor 0.0 Sqm 200.8 0.0 0.0 0.0 0.0 Third Floor 0.0 Sqm 208.7 0.0 0.0 0.0 0.0 Fourth Floor 0.0 Sqm 216.9 0.0 0.0 0.0 0.0 Fifth Floor 0.0 Sqm 225.6 0.0 0.0 0.0 0.0 SiXth Floor 0.0 Sqm 234.7 0.0 0.0 0.0 0.0 |
| 94 | Painting two coats of synthetic enamel paint over Iron Works as per approved shade of approved quality over a coat of primer, sand papering, polishing the surface including cost, conveyance,labour, T&P, scaffolding etc. as required for the work complete as per direction of Engineer-in-charge. (The paints and primer are to be approved before procurement and use) Ground Floor 118.38 33.38 1.62 153.38 Sqm 268.7 41213.206 8969.206 0.0 31808.706 First Floor 17.22 17.22 Sqm 273.6 4711.392 0.0 4711.392 0.0 Second Floor 0.0 Sqm 278.6 0.0 0.0 0.0 0.0 Third Floor 0.0 Sqm 283.7 0.0 0.0 0.0 0.0 Fourth Floor 0.0 Sqm 289.0 0.0 0.0 0.0 0.0 Fifth Floor 0.0 Sqm 294.5 0.0 0.0 0.0 0.0 SiXth Floor 0.0 Sqm 300.1 0.0 0.0 0.0 0.0 Painting two coats of synthetic enamel paint on road work over Plaster or RCC Works like (kerb wall,bridge rcc barrier) as per approved shade of approved quality , sand papering, polishing the surface including cost, conveyance,labour, T&P, scaffolding etc. as required for the work complete as per direction of Engineer-in-charge. (The paints are to be approved before procurement and use) 0.0 0.0 0.0 0.0 0.0 Ground Floor 0.0 Sqm 84.5 0.0 0.0 0.0 0.0 Wall painting with Textured Paint of approved quality of pattern as specified in drawing including cost of all materials, labours ,T&P, carriage, royalty, taxes etc. required for the work all complete as per direction of Engineer-in-charge. 0.0 0.0 0.0 0.0 0.0 Ground Floor 0.0 Sqm 799.1 0.0 0.0 0.0 0.0 First Floor 0.0 Sqm 799.1 0.0 0.0 0.0 0.0 Second Floor 0.0 Sqm 799.1 0.0 0.0 0.0 0.0 Third Floor 0.0 Sqm 799.1 0.0 0.0 0.0 0.0 Fourth Floor 0.0 Sqm 799.1 0.0 0.0 0.0 0.0 Fifth Floor 0.0 Sqm 799.1 0.0 0.0 0.0 0.0 SiXth Floor 0.0 Sqm 799.1 0.0 0.0 0.0 0.0 FLOORING WORK 0.0 0.0 0.0 0.0 |
| 95 | Providing and laying of 600 mm x 600 mm Polished Vitrified floor tiles of premium grade having thickness 8 mm to 10mm conforming to IS 15622:2006 (GrPlain (Ivory) oup-B la) of following sizes. of approved make, quality and colour without any warpage laid over an under layer of 20 mm thick base of cement mortar (1:4) (1 cement: 4 coarse sand) including cutting to size, laying and filling the joints with white cement slurry mixed with colouring pigment to match the shade and colour, cleaning the surfaces including the cost of all materials, cost of all labour, conveyance, royalties, loading, unloading, sundries, watering and curing, T&P, etc. complete as per the direction of the Engineer-in-Charge.(Note- Sample of tiles shall be approved before procurement and use.) Ground Floor 1313.905625 1313.905625 Sqm 1152.5 1514276.2328125 0.0 0.0 1514276.2328125 First Floor 0.0 Sqm 1166.3 0.0 0.0 0.0 0.0 Second Floor 0.0 Sqm 1180.7 0.0 0.0 0.0 0.0 Third Floor 0.0 Sqm 1195.8 0.0 0.0 0.0 0.0 Fourth Floor 0.0 1211.7 0.0 0.0 0.0 0.0 Fifth Floor 0.0 1228.4 0.0 0.0 0.0 0.0 SiXth Floor 0.0 1245.9 0.0 0.0 0.0 0.0 0.0 0.0 0.0 |
| 96 | Providing and laying of 600 mm x 600 mm Anti skid matt finish Vitrified floor tiles of premium grade having thickness 8 mm to 10mm conforming to IS 15622:2006 (Group-B la) of following sizes. of approved make, quality and colour without any warpage laid over an under layer of 20 mm thick base of cement mortar (1:4) (1 cement: 4 coarse sand) including cutting to size, laying and filling the joints with white cement slurry mixed with colouring pigment to match the shade and colour, cleaning the surfaces including the cost of all materials, cost of all labour, conveyance, royalties, loading, unloading, sundries, watering and curing, T&P, etc. complete as per the direction of the Engineer-in-Charge.(Note- Sample of tiles shall be approved before procurement and use.) 0.0 0.0 0.0 |
| 97 | Providing and laying 300mmx300mm printed series ceramic floor tiles of premium grade having thickness 7mm to 8mm conforming to IS 13755 of approved make, quality and colour without any warpage laid over an under layer of 20 mm thick base of cement mortar (1:4) (1 cement: 4 coarse sand) including cutting to size, laying and spacer of 4mm for grouting the joints of tiles using epoxy grout mix of 0.70 kg of organic coated filler of desired shade (0.10 kg of hardener and 0.20 kg of resin per kg) to match the shade and colour, cleaning the surfaces with acid including the cost of all materials, cost of all labour, conveyance, royalties, loading, unloading, sundries, watering and curing, T&P, etc. complete as per the direction of the Engineer-in-Charge.(Note- Sample of tiles shall be approved before procurement and use.) Ground Floor 80.91 80.91 Sqm 1106.2 89502.642 0.0 0.0 89502.642 First Floor 0.0 Sqm 1119.9 0.0 0.0 0.0 0.0 Second Floor 0.0 Sqm 1134.3 0.0 0.0 0.0 0.0 Third Floor 0.0 Sqm 1149.5 0.0 0.0 0.0 0.0 Fourth Floor 0.0 Sqm 1165.4 0.0 0.0 0.0 0.0 Fifth Floor 0.0 Sqm 1182.1 0.0 0.0 0.0 0.0 SiXth Floor 0.0 Sqm 1199.6 0.0 0.0 0.0 0.0 0.0 0.0 0.0 |
| 98 | Providing & laying Heavy Duty Industrial Vetrified Tile having thickness 8 mm to 10mm in floor/dado/skirting confirming to IS : 15622 of size 300mmx300mm of approved make, quality and colour without any warpage laid over an under layer of 12mm thick cement mortar (1:3) (1 cement: 3 coarse sand) confirming to IS-1443 including cutting to size, laying and filling the joints with white cement slurry mixed with colouring pigment to match the shade and colour, cleaning the surfaces including the cost of all materials, cost of all labour, conveyance, taxes, royalties, loading, unloading, sundries, watering and curing, T&P, etc. complete as per the direction of the Engineer-in-Charge.(Note- Sample of tiles shall be approved before procurement and use.) Ground Floor 54.13 54.13 Sqm 1204.4 65194.172000000006 0.0 0.0 65194.172000000006 Providing and laying Chequred Tiles. tiles confirming to IS : 15622 of approved make, quality and colour without any warpage laid over 20 mm thick base of cement mortar (1:4) (1 cement: 4 coarse sand) including cutting to size, laying and filling the joints with white cement slurry mixed with colouring pigment to match the shade and colour, cleaning the surfaces including the cost of all materials, cost of all labour, conveyance, taxes, royalties, loading, unloading, sundries, watering and curing, T&P, etc. complete as per the direction of the Engineer-in-Charge.(Note- Sample of tiles shall be approved before procurement and use.) 0.0 0.0 0.0 0.0 Ground Floor 0.0 Sqm 665.2 0.0 0.0 0.0 0.0 First Floor 0.0 Sqm 678.9 0.0 0.0 0.0 0.0 Providing & laying granite stone flooring using 19-20 mm thick granite stone slab of approved quality, colour and size above 0.4 Sqm as per IS 14223 in Stair Treads and Risers over an under layer of 20 mm thick cement mortar (1:4) (1 cement: 4 coarse sand) confirming to IS-1443 including cutting to size, laying and joining with white cement slurry and colouring pigment to match the shade with typical half nosing and cutting grooves etc including cost of all labour, materials, royalties, loading and unloading, conveyance, sundries, watering and curing, etc. complete as per the direction of the Engineer-in-Charge. (Note- Sample of granite tiles shall be approved before procurement and use.) 0.0 0.0 0.0 0.0 Ground Floor 0.0 Sqm 3210.9 0.0 0.0 0.0 0.0 First Floor 0.0 Sqm 3244.1 0.0 0.0 0.0 0.0 Second Floor 0.0 Sqm 3279.0 0.0 0.0 0.0 0.0 Third Floor 0.0 Sqm 3315.6 0.0 0.0 0.0 0.0 Fourth Floor 0.0 Sqm 3354.0 0.0 0.0 0.0 0.0 Fifth Floor 0.0 Sqm 3394.4 0.0 0.0 0.0 0.0 SiXth Floor 0.0 Sqm 3436.8 0.0 0.0 0.0 0.0 |
| 99 | Providing & laying granite stone flooring in Floors and landing using 19-20 mm thick granite stone slab of approved quality, colour and size above 0.4 Sqm as per IS 14223 laid over an under layer of 20 mm thick cement mortar (1:4) (1 cement: 4 coarse sand) confirming to IS-1443 including cutting to size, laying and filling the joints with white cement slurry mixed with colouring pigment to match the shade and colour, cleaning the surfaces including the cost of all materials, cost of all labour, conveyance, royalties, loading, unloading, sundries, watering and curing, T&P, etc. complete as per the direction of the Engineer-in-Charge.(Note- Sample of granite tiles shall be approved before procurement and use.) Ground Floor 14.35 14.35 Sqm 3154.6 45268.509999999995 0.0 0.0 45268.509999999995 First Floor 0.0 Sqm 3185.0 0.0 0.0 0.0 0.0 Second Floor 0.0 Sqm 3216.9 0.0 0.0 0.0 0.0 Third Floor 0.0 Sqm 3250.4 0.0 0.0 0.0 0.0 Fourth Floor 0.0 3285.6 0.0 0.0 0.0 0.0 Fifth Floor 0.0 3322.6 0.0 0.0 0.0 0.0 SiXth Floor 0.0 3361.4 0.0 0.0 0.0 0.0 Providing & laying granite stone tiles in dado/skirting using 10mm thick granite stone slab of approved quality, colour and size upto 0.4 Sqm as per IS 14223 to proper line, level and slope laid over 12mm thick cement mortar (1: 3) confirming to IS IS-1443 including cutting to size, laying and filling the joints with white cement slurry mixed with colouring pigment to match the shade and colour, cleaning the surfaces including the cost of all materials, cost of all labour, conveyance, royalties, loading, unloading, sundries, watering and curing, T&P, etc. complete as per the direction of the Engineer-in-Charge.(Note- Sample of granite tiles shall be approved before procurement and use.) 0.0 0.0 0.0 0.0 0.0 Ground Floor 0.0 Sqm 2536.0 0.0 0.0 0.0 0.0 First Floor 0.0 Sqm 2579.7 0.0 0.0 0.0 0.0 Second Floor 0.0 Sqm 2625.6 0.0 0.0 0.0 0.0 Third Floor 0.0 Sqm 2673.7 0.0 0.0 0.0 0.0 Fourth Floor 0.0 Sqm 2724.3 0.0 0.0 0.0 0.0 Fifth Floor 0.0 Sqm 2777.4 0.0 0.0 0.0 0.0 SiXth Floor 0.0 Sqm 2833.2 0.0 0.0 0.0 0.0 0.0 0.0 0.0 |
| 100 | Providing & laying kota stone slabs in floors using 16 mm thick kota stone slab of approved quality, colour and size above 0.10 Sqm laid over an under layer of 20 mm thick cement mortar (1:4) (1 cement : 4 coarse sand) confirming to IS-1443 including cutting to size, laying and filling the joints with white cement slurry mixed with colouring pigment to match the shade and colour, cleaning the surfaces including the cost of all materials, cost of all labour, conveyance, taxes, royalties, loading, unloading, sundries, watering and curing, T&P, etc. complete as per the direction of the Engineer-in-Charge.(Note- Sample of tiles shall be approved before procurement and use.) Ground Floor 184.63625000000002 184.63625000000002 Sqm 1297.8 239620.92525000003 0.0 0.0 239620.92525000003 First Floor 0.0 Sqm 1328.2 0.0 0.0 0.0 0.0 Second Floor 0.0 Sqm 1360.1 0.0 0.0 0.0 0.0 Mumty Floor 0.0 Sqm 1393.6 0.0 0.0 0.0 0.0 0.0 0.0 0.0 DADO/SKIRTING WORK 0.0 0.0 0.0 |
| 101 | Providing and laying of Polished Vitrified floor tiles of premium grade having thickness 8 mm to 10mm conforming to IS 15622:2006 (GrPlain (Ivory) oup-B la) in dado/skirting confirming to IS : 15622 of approved make, quality, colour and size 600mm x600mm upto required height from floor level fixed over an under layer of 12mm thick bed of cement mortar (1:3) (1 Cement : 3 Coarse sand) including cutting to size, laying and filling the joints with white cement slurry mixed with colouring pigment to match the shade and colour, cleaning the surfaces including the cost of all materials, cost of all labour, conveyance, taxes, royalties, loading, unloading, sundries, watering and curing, T&P, etc. complete as per the direction of the Engineer-in-Charge.(Note- Sample of tiles shall be approved before procurement and use.) Ground Floor 136.8465 136.8465 Sqm 1288.9 176381.45385 0.0 0.0 176381.45385 First Floor 0.0 Sqm 1309.6 0.0 0.0 0.0 0.0 Second Floor 0.0 Sqm 1331.2 0.0 0.0 0.0 0.0 Third Floor 0.0 Sqm 1354.0 0.0 0.0 0.0 0.0 Fourth Floor 0.0 1377.9 0.0 0.0 0.0 0.0 Fifth Floor 0.0 1403.0 0.0 0.0 0.0 0.0 SiXth Floor 0.0 1429.4 0.0 0.0 0.0 0.0 0.0 0.0 0.0 |
| 102 | Ceramic wall tile With Epoxy Grout For ToiletProviding and laying of printed series ceramic floor tiles of premium grade having thickness 7mm to 8mm conforming to IS 13755 in dado/skirting confirming to IS : 15622 of approved make, quality, colour and size 300mm x 300mm upto required height from floor level fixed over an under layer of 12mm thick bed of cement mortar (1:3) (1 Cement : 3 Coarse sand) including cutting to size, laying and spacer of 4mm for grouting the joints of tiles using epoxy grout mix of 0.70 kg of organic coated filler of desired shade (0.10 kg of hardener and 0.20 kg of resin per kg) to match the shade and colour, cleaning the surfaces with acid including the cost of all materials, cost of all labour, conveyance, taxes, royalties, loading, unloading, sundries, watering and curing, T&P, etc. complete as per the direction of the Engineer-in-Charge.(Note- Sample of tiles shall be approved before procurement and use.) Ground Floor 319.18 319.18 Sqm 1131.6 361184.088 0.0 0.0 361184.088 First Floor 0.0 Sqm 1152.2 0.0 0.0 0.0 0.0 Second Floor 0.0 Sqm 1173.9 0.0 0.0 0.0 0.0 Third Floor 0.0 Sqm 1196.7 0.0 0.0 0.0 0.0 Fourth Floor 0.0 Sqm 1220.6 0.0 0.0 0.0 0.0 Fifth Floor 0.0 Sqm 1245.7 0.0 0.0 0.0 0.0 SiXth Floor 0.0 Sqm 1272.0 0.0 0.0 0.0 0.0 Ceramic wall tile Without Epoxy GroutProviding and laying of Glazed Ceramic Wall Tiles in dado/skirting confirming to IS : 15622 of approved make, quality, colour and size 400mm x 300mm upto required height from floor level fixed over an under layer of 12mm thick bed of cement mortar (1:3) (1 Cement : 3 Coarse sand) including cutting to size, laying and filling the joints with white cement slurry mixed with colouring pigment to match the shade and colour, cleaning the surfaces including the cost of all materials, cost of all labour, conveyance, taxes, royalties, loading, unloading, sundries, watering and curing, T&P, etc. complete as per the direction of the Engineer-in-Charge.(Note- Sample of tiles shall be approved before procurement and use.) 0.0 0.0 0.0 0.0 0.0 Ground Floor 0.0 Sqm 1007.6 0.0 0.0 0.0 0.0 First Floor 0.0 Sqm 1028.2 0.0 0.0 0.0 0.0 Second Floor 0.0 Sqm 1049.9 0.0 0.0 0.0 0.0 Mumty Floor 0.0 Sqm 1072.7 0.0 0.0 0.0 0.0 0.0 0.0 0.0 |
| 103 | Providing & laying kota stone slabs in dado/Skirting using 16 mm thick Kota stone of approved quality, colour and size above 0.10 Sqm laid over an under layer of 12mm thick cement mortar (1:3) (1 cement: 3 coarse sand) confirming to IS-1443 including cutting to size, laying and filling the joints with white cement slurry mixed with colouring pigment to match the shade and colour, cleaning the surfaces including the cost of all materials, cost of all labour, conveyance, taxes, royalties, loading, unloading, sundries, watering and curing, T&P, etc. complete as per the direction of the Engineer-in-Charge.(Note- Sample of tiles shall be approved before procurement and use.) Ground Floor 49.367699999999985 49.367699999999985 Sqm 1574.4 77724.50687999999 0.0 0.0 77724.50687999999 First Floor 0.0 Sqm 1618.1 0.0 0.0 0.0 0.0 Second Floor 0.0 Sqm 1664.0 0.0 0.0 0.0 0.0 Mumty Floor 0.0 Sqm 1712.2 0.0 0.0 0.0 0.0 BUILT IN JOINERIES 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 |
| 104 | Providing edge moulding and groove cutting in granite tiles as per drawing and design for granite stone counters, steps, Vanities etc., including machine polishing to edge to give high gloss finish etc. complete as per direction of Engineer-in-Charge. 0.0 0.0 0.0 DOOR & CHOUKATH WORKS 0.0 0.0 0.0 |
| 105 | Providing and fixing 65mm X 125mm factory made single extruded WPC (Wood Polymer Composite) solid door/window/Ceosetory windows & other Frames/Chowkhat comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modulus of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with M.S hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-In- Charge.Note: For WPC solid door/window frames, minus 5mm tolerance in dimensions i.e depth and width of profile shall be acceptable. Variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be made. Ground Floor 234.55 234.55 Rmt 1252.4 293750.42000000004 0.0 0.0 293750.42000000004 First Floor 0.0 Rmt 1252.4 0.0 0.0 0.0 0.0 Second Floor 0.0 Rmt 1252.4 0.0 0.0 0.0 0.0 Third Floor 0.0 Rmt 1252.4 0.0 0.0 0.0 0.0 Fourth Floor 0.0 Rmt 1252.4 0.0 0.0 0.0 0.0 Fifth Floor 0.0 Rmt 1252.4 0.0 0.0 0.0 0.0 SiXth Floor 0.0 Rmt 1252.4 0.0 0.0 0.0 0.0 Supplying, fitting and fixing of 32mm thick flush door shutter with approved quality of 30mm thick BWR block board pasted with 1mm thick sunmica on both side of approved design and quality including cost of all door fittings and fixtures etc. complete 0.0 0.0 0.0 0.0 0.0 Ground Floor 0.0 Sqm 10668.61 0.0 0.0 0.0 0.0 First Floor 0.0 Sqm 10668.61 0.0 0.0 0.0 0.0 Second Floor 0.0 Sqm 10668.61 0.0 0.0 0.0 0.0 Third Floor 0.0 Sqm 10668.61 0.0 0.0 0.0 0.0 Fourth Floor 0.0 Sqm 10668.61 0.0 0.0 0.0 0.0 Fifth Floor 0.0 Sqm 10668.61 0.0 0.0 0.0 0.0 SiXth Floor 0.0 Sqm 10668.61 0.0 0.0 0.0 0.0 |
| 106 | Providing and fixing 45mm X 75mm or 90 mm x 50 mm factory made single extruded WPC (Wood Polymer Composite) solid door/window/Ceosetory windows & other Frames/Chowkhat comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modulus of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with M.S hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-In- Charge.Note: For WPC solid door/window frames, minus 5mm tolerance in dimensions i.e depth and width of profile shall be acceptable. Variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be made. Ground Floor 74.25 74.25 Rmt 720.96 53531.280000000006 0.0 0.0 53531.280000000006 First Floor 0.0 Rmt 720.96 0.0 0.0 0.0 0.0 Second Floor 0.0 Rmt 720.96 0.0 0.0 0.0 0.0 Mumty Floor 0.0 Rmt 720.96 0.0 0.0 0.0 0.0 |
| 107 | Providing and fixing factory made single extruded 30 MM THICK WPC (Wood Polymer Composite) solid plain flush door shutter of required size comprising of virgin polymer of K value 58-60(Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheathusk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimumdensity of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge),minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/ moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per directionof Engineer-In- Charge.(Make: WPC: Century / Black Cobra / Rajshri Plastiwood, Hardware Fittings: Godrej / Dorset / Link / Dorma) Ground Floor 23.63 23.63 Sqm 4106.26 97030.9238 0.0 0.0 97030.9238 |
| 108 | Providing and fixing factory made single extruded 35 MM THICK WPC (Wood Polymer Composite) solid plain flush door shutter of required size comprising of virgin polymer of K value 58-60(Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/ moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer-In- Charge. (Make: WPC: Century / Black Cobra / Rajshri Plastiwood, Hardware Fittings: Godrej / Dorset / Link / Dorma) Ground Floor 104.48 104.48 Sqm 4961.3 518356.624 0.0 0.0 518356.624 First Floor 0.0 Sqm 4961.3 0.0 0.0 0.0 0.0 Mumty Floor 0.0 Sqm 4961.3 0.0 0.0 0.0 0.0 Supplying and fitting-fixing of factory made single leaf rigid FRP (alternately called GRP) sandwich composite door shutter of 32mm thick laminated with two GRP skins with wood grain finish fabricated using UV-stabilised Isopthalic Gelcoat and one layer of 450 gsm E-glass Chopped Strand Mat (CSM) impregnated with orthopthalic palyester resin. The thickness of the skins shall not be less than 3.00 mm Expanded Polystyrone(EPS) structural foam panel of 29mm thickness and a density of 20kg/cu.mtr shall be used as core material. Wooden reinforcements made of seasoned sal wood block of cross section not less than 28mmx32mm and also necessary sal wood reinforcements for fitting the metal fittings such as tower bolts, aldrops, handles etc shall be provided. A structural adhesive compatible with (EPS) foam shall be used for bending the core material, the sal wood reiforcements and the skins. The material and process for manufacturing the door shutters shall conform to RV-TIFAC composites Design Centre's standards and specifications and the door shutters tested in conformation to IS: 4020-1998. The finish of door shutter will be plain colour white/ Ivory/ Beige/ Light grey/ Mahogany/ Teak wood or any other colour using high quality pigments. Three heavy whight mild steel butt hinges type-I(ISI marked) size 100mm are to be fitted on one side of shutter. 0.0 0.0 0.0 0.0 0.0 Ground Floor 0.0 Sqm 6172.1 0.0 0.0 0.0 0.0 First Floor 0.0 Sqm 6172.1 0.0 0.0 0.0 0.0 Second Floor 0.0 Sqm 6172.1 0.0 0.0 0.0 0.0 Third Floor 0.0 Sqm 6172.1 0.0 0.0 0.0 0.0 Fourth Floor 0.0 Sqm 6172.1 0.0 0.0 0.0 0.0 Fifth Floor 0.0 Sqm 6172.1 0.0 0.0 0.0 0.0 SiXth Floor 0.0 Sqm 6172.1 0.0 0.0 0.0 0.0 Providing and fixing factory made 2.5 track KOMMERLING UPVC white colour sliding window with SS mesh comprising of uPVC multi-chambered frame having section Frame 88mm x 49mm, Window sash: 37mm x 61mm, Bugmesh sash: 58mm x 32mm made out of lead free green profiles with comers fusion welded, fully reinforced with Galvanized steel 1.5 mm. The windows profile should fulfill the requirements of Viny 2010. The physical properties of the profiles like Vicat softening temperature, density, tensile strength, hardness, weatherability, impact strength and Modulus of Elasticity should be tested in accordance with ASTM/DIN-ISO standards and the thermal conductivity as per IS standards. The window comprising of uPVC extruded glazing beads of appropriate dimension, EPDM gasket, G.I fasteners 100 x 8 mm size for fixing frame to finished wall, plastic packers, plastic caps and necessary stainless steel screws etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of required size. The sash will be fitted with 5mm clear glass 0.0 0.0 0.0 0.0 0.0 Ground Floor 0.0 Sqm 8900.0 0.0 0.0 0.0 0.0 First Floor 0.0 Sqm 8900.0 0.0 0.0 0.0 0.0 Second Floor 0.0 Sqm 8900.0 0.0 0.0 0.0 0.0 Third Floor 0.0 Sqm 8900.0 0.0 0.0 0.0 0.0 Fourth Floor 0.0 Sqm 8900.0 0.0 0.0 0.0 0.0 Fifth Floor 0.0 Sqm 8900.0 0.0 0.0 0.0 0.0 SiXth Floor 0.0 Sqm 8900.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 |
| 109 | Supplying and fixing of Powder coated 50-60 microns approved colour of aluminium 40mm Casement series Door Unit with suitable aluminium extrude profiles. the system is designed to accommodate 12mm clear toughened glass. the rate quoted inclusive of hardwares like antilift, roller, Espag lock cum handle, epdm gaskets, T mullion, Fly Mullion, bottom adopter, mid transom, glazing clip for 12 mm glass felt along with all accessories etc complete. The gap between the wall and window will be filled with silicon weather sealant in the outer side. including the cost of all materials ,hardware fittings,cost of all labour, conveyance, loading, un loading, T&P, etc, complete as per the direction of Engineer-in Charge.(As per Proceeding of C.C.E. Level committee meeting held on dt. 12.02.2024 at 11.30 A.M.) Ground Floor 8.64 8.64 Sqm 12427.8 107376.192 0.0 0.0 107376.192 0.0 0.0 0.0 WINDOW & VENTILATOR WORKS 0.0 0.0 0.0 0.0 0.0 0.0 |
| 110 | Supplying , fitting and fixing of two track UPVC sliding window of approved make with 6mm thick glass of approved quality complete with frame, shutters and all fitting and fixtures.. complete in all respect as per the direction of the Engineer-in-Charge. Ground Floor 149.02 149.02 Sqm 4960.97 739283.7494000001 0.0 0.0 739283.7494000001 First Floor 0.0 Sqm 4960.97 0.0 0.0 0.0 0.0 Second Floor 0.0 Sqm 4960.97 0.0 0.0 0.0 0.0 Third Floor 0.0 Sqm 4960.97 0.0 0.0 0.0 0.0 Fourth Floor 0.0 Sqm 4960.97 0.0 0.0 0.0 0.0 Fifth Floor 0.0 Sqm 4960.97 0.0 0.0 0.0 0.0 SiXth Floor 0.0 Sqm 4960.97 0.0 0.0 0.0 0.0 0.0 0.0 0.0 |
| 111 | Supplying and fitting -fixing of Un-plasticised poly Vinyl Chloride (UPVC) (FENESTA/NCL VECCA LTD) Ventillator/Top Hung-60 Series duly manufactured using UPVC reinforced Profiles of 60mmx 55mmx2.5mm for outer frames ,75mmx60mmx2.25mm for casement window sash profile capable of mounting single glazing system,structurally reinforced with hot dip galvanised upto 50 microns of minimum thickness of 1.5 mm prefabricted and welded through fusion welding the wwindow sash shall be fitted with 6mm thick clear toughened glass of Saint-Gobain make duly fixed with EPDM weathering seal resistant accessories like clipping locking system made of aluminium 1 no per set of sashes and the system to be installed at the site using anchor fasteners,silicon rubber sealant,easy glazing/deglazing at siteetc including cost and conveyance of all accessories labour charges,materials and product confirming to ASTM D 638-14,EN-477-95 and other applicable codes and standards. Ground Floor 6.48 6.48 Sqm 7115.0 46105.200000000004 0.0 0.0 46105.200000000004 Supplying, fitting and fixing of UPVC Partition Wall I60 Casement Series 1-OFF as per drawing and specification: Top member-6mm Tinted/Laminated/Colored/Clear Toughened Glass & Bottom member-PVC Sheet (12-18mm), Weight: 291.36 kg, Colour-White Dimension Type-Frame Size from RO, Frame Depth-60mm, Hinged Series-I60 Casement, Reinforcement-Full, Coupling 180-33mm/2108-3106+56016-10070, Window O/F-55mm/41101-11000+R1, Frame T/M-74mm/41101-12000/12100+56016-10001, T-Joins-Mechanical, Frame Mech-50502-11016, Connector-Shape 1, Bead Shape-Glazing Packer 16.5 x 77 x 5 mm, Cmnt Gl Packer-No, Grill required-Supply & Install, Supply Type-280ml bottle, Silicon Sealant-No, Display Fixings-Face with drainage including scaffolding complete in all respect as per the direction of the Engineer-in-Charge. 0.0 0.0 0.0 0.0 0.0 Ground Floor 0.0 Sqm 4142.68 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 Providing and fixing 12 mm thick frame less toughened glass partition Dorma Premium (911298) PT 90 Side Connector and PT 80 Glass to glass Connector with Silicone,12mm Clear Toughened Glass with Cutout and Hole,including perimeter sealing of glass to glass joints with silicon sealant ,etc.as per drawing and specification including the cost of all materials ,T&P,etc all complete as per the direction of Engineer-in-Charge. 0.0 0.0 0.0 0.0 0.0 Ground Floor 0.0 Sqm 10223.2 0.0 0.0 0.0 0.0 Providing and fixing of 12mm thick Clear Toughened Glass Frameless Door With Dorma Premium Fittings. Dorma Premium (9111198) Unilite Package BTS 75 UL PT 10 with Cover, UL PT 20 with Cover UL US 10 Luck with Cover and PT. 24. Dorma Premium (9137121) H Type Handle 450mm, 12mm Clear Toughened Glass with Cutout and Hole including the cost of ali materials hardware fittings, cost of all labour, conveyance. loading, unloading. T&P, etc, complete as per the direction of Engineer-in-Charge 0.0 0.0 0.0 0.0 0.0 Ground Floor 0.0 Sqm 11343.2 0.0 0.0 0.0 0.0 0.0 0.0 0.0 STRUCTURAL STEEL & GLAZING WORKS 0.0 0.0 0.0 |
| 112 | Supplying, fitting & fixing of M.S grills for (windows, ventilators & grill gates) madeout of M.S angle/M.S flat/M.S solid bar/M.S sections including cost of screws as per approved design & dimensions, electrically welded properly with all locking arrangrments including cost of materials, labour, carriage etc. complete as per the direction of the Engineer-in-Charge. Ground Floor 4640.0 1668.75 32.400000000000006 6341.15 Kg 89.61 568230.4515 149536.6875 0.0 415790.4 Terrace 344.4 344.4 Kg 89.61 30861.683999999997 0.0 30861.683999999997 0.0 Second Floor 0.0 Kg 89.61 0.0 0.0 0.0 0.0 Third Floor 0.0 Kg 89.61 0.0 0.0 0.0 0.0 Fourth Floor 0.0 Kg 89.61 0.0 0.0 0.0 0.0 Fifth Floor 0.0 Kg 89.61 0.0 0.0 0.0 0.0 SiXth Floor 0.0 Kg 89.61 0.0 0.0 0.0 0.0 S.S Railing 0.0 0.0 0.0 0.0 |
| 113 | Supplying, fabricating & fixing of polished stainless steel (304 grade) items made out of pipes, angles, flats, plates, hollow tube, square pipe bracing as per approved design and specification, buffing, polishing etc. with cost, conveyance, labour in railing, parapet, staircase, space frame etc required for the work complete in all respect as per direction of Engineer-in-charge. Ground Floor 403.1 403.1 Kg 343.8 138585.78 0.0 0.0 138585.78 Terrace 0.0 Kg 343.8 0.0 0.0 0.0 0.0 Second Floor 0.0 Kg 343.8 0.0 0.0 0.0 0.0 Third Floor 0.0 Kg 343.8 0.0 0.0 0.0 0.0 Fourth Floor 0.0 Kg 343.8 0.0 0.0 0.0 0.0 Fifth Floor 0.0 Kg 343.8 0.0 0.0 0.0 0.0 SiXth Floor 0.0 Kg 343.8 0.0 0.0 0.0 0.0 G.R.C. JALI :-Providing and fixing Glass Reinforced Concrete (GR.C) Screens in approved size pattern, design, shadeand thickness of 50mm on frame and design element in 30mm thick have weight approximately between 3.5 4 Kg per Sq Ft and color of M/S UniStone make or equivalent. The above weight and thickness is considering dimensions of screens up to 2133mm in height and 1219mm in width and having at least 50% void space. The screens should be made from '53 grade' White Portland Cement manufactured by JK Cement' or equivalent, Quartz, Fine Silica Sand, Alkali Resistant Glass Fiber manufactured by 'N.E.G JAPAN or equivalent, Super Plasticizers manufactured by \\"BASF or equivalent Polymers manufactured by 'BASF or equivalent and UV resistant Synthetic inorganic pigments should be used for pigmentation manufactured by 'BAYFERROX (Germany) or equivalent. The material casting should take place in FRP Molds. The fixing of Screens should be 'Dry fixing' Le to be done with M.S Galvanized Clamps, fixtures and fasteners of Hilti / Fischer. 0.0 0.0 0.0 0.0 0.0 Ground Floor 0.0 Kg 8711.3 0.0 0.0 0.0 0.0 First Floor 0.0 Kg 8711.3 0.0 0.0 0.0 0.0 Second Floor 0.0 Kg 8711.3 0.0 0.0 0.0 0.0 TERACE/TOILET WATERPROOFING WORK 0.0 0.0 0.0 0.0 0.0 modified cementitious waterproofing coating over roof slab/Toilet after carrying out pond test on roof slab/Toilet, filling all defects, saturating the surface, mixing the products and then application in 2.0 mm thickness (1.8 Kg / sqm coverage rate for 1.0 mm thickness) in suitable layers complete in all respect, all materials, tools, plant & labour complete in all respect. Density 1850kg/m³ , Mix ratio (Powder to liquid) 3:1 by weight ,Water penetration Din 1048 1.5 Bar no leakage Potlife @ 25°C 2 hours & @ 40°C 30 minutes,Recoatable: 8-12 hours Elongation >42% (air) & >31% (under water),Tensile strength >20 kg/cm2 ,VOC content (HK prod code P10-17) 0.5 g/L including cost of all materials, conveyance, taxes and sundries,T&P, watering and curing by ponding water over terrace slab etc. complete as per the direction of the Engineer-in-charge. 0.0 0.0 0.0 0.0 0.0 Ground Floor 0.0 Sqm 543.6 0.0 0.0 0.0 0.0 Terrace 0.0 Sqm 543.6 0.0 0.0 0.0 0.0 Second Floor 0.0 Sqm 543.6 0.0 0.0 0.0 0.0 Third Floor 0.0 Sqm 543.6 0.0 0.0 0.0 0.0 Fourth Floor 0.0 Sqm 543.6 0.0 0.0 0.0 0.0 Fifth Floor 0.0 Sqm 543.6 0.0 0.0 0.0 0.0 SiXth Floor 0.0 Sqm 543.6 0.0 0.0 0.0 0.0 Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. 0.0 0.0 0.0 0.0 0.0 Ground Floor 0.0 Sqm 96.1 0.0 0.0 0.0 0.0 Supplying and fixing of Colour coated galvalume metal sheets Zinc aluminum alloy coated, Not less than 150 gms/sq.m, having high tensile steel sheet (Fy 550 Mpa) of 0.5 mm minimum thickness (BMT). The outside face (exposed face) shall be permanently color coated with PVF-2 paint of minimum DFT 20 microns over primer and inner side (internal face) shall be coated with same paint of minimum DFT 12 microns ,Colour Coated Flashing & Ridge board with all fasteners and fixtures, scaffolding etc. complete at all heights as per drawings and specification including preparation of bill of materials & shop drawings. (Galvalume Sheets shall be of any reputed make including Kingspan Jindal/'Tata Blue Scope Steel Limited', 'Laj Color Leaf (P) Limited' Loyd Insulations etc.) 0.0 0.0 0.0 0.0 0.0 Ground Floor 0.0 Sqm 1231.2 0.0 0.0 0.0 0.0 Micro Concreting1. Surface PreparationRemoving all loose and unsound concrete from the damaged area by mechanical means/manual chipping without damaging the parent concrete.Cleaning of reinforcement with rust remover to remove all loose rust and scale.2. Steel ProtectionApplication of zinc-rich primer over cleaned reinforcement steel to prevent further corrosion.3. Bonding CoatApplication of bond coat consisting of cement slurry mixed with SBR Latex (Dr. Fixit Pidicrete URP or equivalent) over the prepared surface to ensure proper bonding between old and new concrete.4. Repair Mortar / Micro ConcreteFilling of repaired pockets with Polymer Modified Mortar (PMM) for small thickness repairs.For larger sections, use Dr. Fixit Micro Concrete to restore the structural profile.5. Waterproofing TestAfter repairs, carry out ponding test on the opposite surface of the roof slab to check for any leakage/seepage.6. Injection GroutingIn case of observed seepage/leakage, carry out pressure injection grouting with suitable grout material (epoxy as specified) to arrest water ingressComplete as per the direction of the Engineer-in-Charge. (Note- Sample of materials shall be approved before procurement and use.) 0.0 0.0 0.0 0.0 0.0 Ground Floor 0.0 Sqm 3891.0 0.0 0.0 0.0 0.0 Groove cut the existing crack on concrete/masonry surface and remove all dust and loose particles, fill the cracks with Renderoc FC and inject the cracks by pressure grouting using Conbextra Cable Grout using PVC nozzles at speed less than 1 kg/cm2, Cut slits of 3 to 5mm width on the joints of crack line to depth of 15mm and 155mm on either side of crack, fill the groove with Renderoc SP40 and insert Nitoplate Crackfix plate having tensile strength >1000 MPA, fiber content 50 - 60% into the filled groove. Item rate is inclusive of materials all labour, tools and tackles, and transportation etc. complete as per specification and as directed by Engg.-in-charge. Payment shall be made as per actual site measurement.(Note- Sample of materials shall be approved before procurement and use.) 0.0 0.0 0.0 0.0 0.0 all Floor 0.0 Rmt 731.7 0.0 0.0 0.0 0.0 Providing and fixing GI chicken wire mesh 24 gauge and 12 mm mesh and required wideth for construction joints and chasing in brick work for electrical conduits or water supply pipes including cement slurry and pegs/nails with nailing machine as required before pastering etc. complete as directed by the Engineer-in-charge.(Note- Sample of materials shall be approved before procurement and use.) 0.0 0.0 0.0 0.0 0.0 all Floor 0.0 Rmt 186.0 0.0 0.0 0.0 0.0 Chequred Tiles 300mmx300mm of approved make, quality and colour without any warpage laid over an under layer of 20 mm thick base of cement mortar (1:4) (1 cement: 4 coarse sand) including cutting to size, laying and filling the joints with white cement slurry mixed with colouring pigment to match the shade and colour, cleaning the surfaces with oxlaic acid, machine grinding, mirror polishing including the cost of all materials, cost of all labour, conveyance, royalties, loading, unloading, sundries, watering and curing, T&P, etc. complete as per the direction of the Engineer-in-Charge.(Note- Sample of tiles shall be approved before procurement and use.) 0.0 0.0 0.0 0.0 0.0 Ground Floor 0.0 Rmt 665.2 0.0 0.0 0.0 0.0 Vetrified industrial floor Tile of premium grade having thickness 15mm to 16mm confirming to IS 4457 of size 600mmx600mm of approved make, quality and colour without any warpage laid over an under layer of 20 mm thick base of cement mortar (1:4) (1 cement: 4 coarse sand) including cutting to size, laying and filling the joints with white cement slurry mixed with colouring pigment to match the shade and colour, cleaning the surfaces with oxlaic acid, machine grinding, mirror polishing including the cost of all materials, cost of all labour, conveyance, royalties, loading, unloading, sundries, watering and curing, T&P, etc. complete as per the direction of the Engineer-in-Charge.(Note- Sample of tiles shall be approved before procurement and use.) (Make:Somany/Jhonson/RAK/kajaria) 0.0 0.0 0.0 0.0 0.0 Ground Floor 0.0 Sqm 2010.1 0.0 0.0 0.0 0.0 Finishing with Epoxy paint (Two or more coats) on steel work at all locations prepared and applied as per manufacturer's ecifications including appropriate priming coat (Red Oxide Zinc Chromate) , preparation of surface, etc. complete as per Direction of E.I.C. 0.0 0.0 0.0 0.0 Ground Floor 0.0 Sqm 272.4 0.0 0.0 0.0 0.0 Pressed Steel Doors With Vision PanelSupply installation of pressed steel doors of the specified dimensions and accessories such as hinges,door,stopper,tower bolt,door handle,door closer,dead lock,consedaled flush bolt,shaft lock,martise lock and vision panel etc.complete as mentioned along with warranty coverrage and after sales service etc.inclusive of all costs,delivery charge,fixing,fitting and any other invidental charges etc.complete excluding GST1. Hinges 2. Tower bolt 3. Door Stopper 4. Mortise Lock 5. Buffer (Make: Tata pravesh,Shaktihormann ETC) 0.0 0.0 0.0 0.0 0.0 Ground Floor 0.0 0.0 0.0 0.0 0.0 General Steeldoor Set 1000X2100 mm Single leaf door with vision panel 0.0 Each 22968.7 0.0 0.0 0.0 0.0 General Steeldoor Set 2,000.00X2,400.00 mm Double leaf door with vision panel 0.0 Each 41558.5 0.0 0.0 0.0 0.0 0.0 0.0 0.0 Providing gola 75x75 mm in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 stone aggregate 10 mm and down gauge), including finishing with cement mortar 1:3 (1 cement : 3 fine sand) as per standard design. 0.0 Rmt 258.60169491525426 0.0 0.0 0.0 0.0 Supplying and fitting-fixing of Un-plasticised Poly Vinyl Chloride (UPVC) Fixed window of approved make with 6mm thick glass of approved quality complete with frame, and all fitting and fixtures etc. complete in all respect as per the direction of the Engineer-in-Charge. 0.0 Sqm 5320.0 0.0 0.0 0.0 0.0 Supplying and fitting-fixing of Un-plasticised Poly Vinyl Chloride (UPVC) Fixed Partition of approved make with 6mm thick glass of approved quality complete with frame, and all fitting and fixtures etc. complete in all respect as per the direction of the Engineer-in-Charge. 0.0 Sqm 8620.0 0.0 0.0 0.0 0.0 Supplying, fitting and fixing of 5.5mm thick hexagonal Aluminium jally in windows as single groove, double groove and tapered clip as horizontal and vertical members for fixing of aluminium jally and joiting angle confirming to standrad Aluminium sections etc. complete as directed by the Engineer-in-charge. 0.0 Sqm 1841.0 0.0 0.0 0.0 0.0 Supplying and fixing of Hospital Glow Letter Type Name Board (Acrylic) including cost of designing, material, machine cutting & labour for mounting complete in all respect as directed by the Engineer-in-Charge.(Rate Per Letter) 0.0 Nos 3750.0 0.0 0.0 0.0 0.0 |
| 114 | Providing and fixing machine moulded aluminium covering of approved pattern & design,made out of machine cut aluminium sheet and machine holed for receiving dash fastener,over expansion joints on vertical surfaces/ceiling floors, the fixing on plate in one row on one side of joint only shall be done with stainless steel dash fasteners of 8 mm dia and 75 mm long bolt including providing aluminium washers 2 mm thick & 15 mm dia , at a staggered pitch of 200mm centre to centre including drilling holes in the receiving surface and providing expandable plastic sleeves in holes etc. complete as per direction of Engineer-in-charge. DAR-AW-Item No. 21.7-2023 Anodised aluminium sheet 2.5mm thick (anodised transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC 15) DAR-AW-Item No. 21.7.1-2023 G.R.C. JALI -Providing and fixing Glass Reinforced Concrete (GR.C) Screens in approved size pattern, design, shadeand thickness of 50mm on frame and design element in 30mm thick have weight approximately between 3.5 4 Kg per Sq Ft and color of M/S UniStone make or equivalent. The above weight and thickness is considering dimensions of screens up to 2133mm in height and 1219mm in width and having at least 50% void space. The screens should be made from '53 grade' White Portland Cement manufactured by JK Cement' or equivalent, Quartz, Fine Silica Sand, Alkali Resistant Glass Fiber manufactured by 'N.E.G JAPAN or equivalent, Super Plasticizers manufactured by \\"BASF or equivalent Polymers manufactured by 'BASF or equivalent and UV resistant Synthetic inorganic pigments should be used for pigmentation manufactured by 'BAYFERROX (Germany) or equivalent. The material casting should take place in FRP Molds. The fixing of Screens should be 'Dry fixing' Le to be done with M.S Galvanized Clamps, fixtures and fasteners of Hilti / Fischer. complete in all respect as per specification & direction of the Engineer-in-Charge. 0.0 Sqm 5928.7 0.0 0.0 0.0 0.0 Gypsum Board False Ceiling - Providing fitting and fixing of gypsum board false ceilling with aluminium anodised T Section No. 3215 with 2'-0\\" center to center, L section No. 1705 upto 15 micron on 4 walls to be fixed by means of steel screw and P.V.C plug and the Aluminium grid 2'-0\\"x2'-0\\" suspended from ceiling etc complete in all respect as per specification & direction of the Engineer-in-Charge. 0.0 Sqm 3017.1 0.0 0.0 0.0 0.0 Providing and fixing false ceiling with Trio/Hexa/Quadra UPVC Soffit Panels of approved make, shade, and finish, manufactured from high-quality virgin uPVC, suitable for interior use and resistant to moisture, termites, rot, and corrosion, including all materials and labour. The panels shall be fixed on a G.I. framework comprising galvanized iron channels, runners, supports, clamps, screws, anchors, and fasteners of adequate gauge, properly aligned, leveled, and securely fixed to the wall/structure. The work shall include supply of panels, G.I. components, trims, corner and edge profiles, joint covers, sealants, cutting, fixing, finishing, scaffolding, tools, and workmanship, ensuring neat joints and a uniform finish, complete in all respects as per manufacturer’s specifications and directions of the Engineer-in-Charge. 0.0 Sqm 4778.3 0.0 0.0 0.0 0.0 Providing and fixing wall panelling using Quadra /Hexa uPVC soffit panels of approved make, shade, and finish, manufactured from high-quality virgin uPVC, suitable for interior use and resistant to moisture, termites, rot, and corrosion, including all materials and labour. The panels shall be fixed on a G.I. framework comprising galvanized iron channels, runners, supports, clamps, screws, anchors, and fasteners of adequate gauge, properly aligned, leveled, and securely fixed to the wall/structure. The work shall include supply of panels, G.I. components, trims, corner and edge profiles, joint covers, sealants, cutting, fixing, finishing, scaffolding, tools, and workmanship, ensuring neat joints and a uniform finish, complete in all respects as per manufacturer’s specifications and directions of the Engineer-in-Charge. 0.0 Sqm 4724.2 0.0 0.0 0.0 0.0 Supply and fixing WPC Louvre of 2440 x 190 x 24mm having 55% wood powder and 30% HDPE: density of 1.425gm/ cm3: tensile strength of 29Mpa: modulous elasticity of 3500 Mpa: coefficient of thermal expansion 6 x 10-5 1/K and having anti-termite properties to be fixed with 25mm x 50mm x 1mm aluminum hollow section on the back of the Louvre with a greed work of 400mm gapcenter to center with all Labor, material, wastage, etc – all complete at site and directions of the Engineer-in-Charge. 0.0 Sqm 7164.1 0.0 0.0 0.0 0.0 Supplying , fitting and fixing of grid mineral fibre ceiling board having size 600 mm x 600 mm x 16mm of approved design and quality complete with frame and all fitting and fixtures. 0.0 0.0 1604.0 0.0 0.0 0.0 0.0 Providing, fitting and fixing of Sikadur Combiflex SG 20P 200 and sealed by Sikadur 31C @ 1.4kg per meter over the expansion joints after cleaning the joints and applying of Sikadur 32 @ 200 gms per meter Epoxy bonding agent and levelled by Sikagrout 214 @ 8kg per meter and covered with 300mm wide 16 gauge Aluminium sheet complete including cost, conveyance, taxes of all materials, labour, transportation charges etc as per specification and direction of the Engineer-in-charge. 0.0 0.0 0.0 0.0 0.0 Providing & fixing G.C.I. Sheet in roof including fixing of ridges wind ties etc. complete but excluding cost of fitting including drilling holes in wind ties etc. complete as per the direction of the Engineer-in-Charge.(Note- Sample shall be approved before procurement and use.) 0.0 Sqm 641.5 0.0 0.0 0.0 0.0 BWP 710 Grade Plywood & Mica Work - Making and fixing plywood work as per drawing and specification (main Str./body 18-19mm, doors 12-15mm, back panel 6-9mm thickness) with mica finishing for cupboard/racks/shelves/wardrobe with all necessary accessories i.e. metal handles, hinges, clamps, locks and screws etc. of approved quality including cost of all materials, labour & T&P etc complete as per direction of the Engineer-in-charge. 0.0 Sqm 11110.7 0.0 0.0 0.0 0.0 Ply Board & Mica Work :- Ply work with mica Finishing including cost of all materials, labour & T&P etc complete as per direction of the Engineer-in-charge. 0.0 Sqm 5456.0 0.0 0.0 0.0 0.0 Providing and applying two coats Unitile’s ‘Rodeo’ make or ‘Asian Paints’ in approved shade on a smooth cement sand plaster. The composition of the texture paint should consist of Acrylic Copolymer Resigns combined with Quartz, Silica, mineral aggregates, synthetic inorganic pigments, bactericide, fungicides and various other additives, giving the product water repellent properties. The first coat to be applied by brush or wool roller as a base coat, diluted with sufficient water and the final coat (Undiluted) to be applied by trowel and finished with acrylic trowel to obtain specified grooves. The thickness of both coats should be 1.0 to 1.5mm. The water repellence of the product is 86 gm/m2 as per test method IS: 5410 ‐1969. required for the work all complete as per direction of Engineer-in-charge. 0.0 Sqm 1159.2 0.0 0.0 0.0 0.0 Providing and executing mural painting work on the specified wall surface using high-quality, weather-resistant acrylic/emulsion paints of approved make and shade, including surface preparation by cleaning, scraping, minor crack filling, smoothing, and application of primer as required. The mural artwork shall be concept-based, aesthetically appealing, and executed by skilled artists as per approved design, theme, color scheme, and drawings, ensuring uniform finish, sharp detailing, and long-lasting color fastness. The work shall include all materials, labour, scaffolding, tools, protection of surrounding areas, and finishing complete in all respects as directed by the Engineer-in-Charge. 0.0 Sqm 1568.0 0.0 0.0 0.0 0.0 Heavy Duty Rope Clothesline Ideal for Drying Heavy Clothes 4 mm Thickness Nylon ClotheslineWhite. 0.0 Sqm 29.0 0.0 0.0 0.0 0.0 Supplying and fixing of Hospital Glow Letter Type Name Board (Acrylic) mentioning \\"VASTALYA SADAN \\" size as per specification including cost of designing, material, machine cutting & labour for mounting complete in all respect as directed by the Engineer-in-Charge. 0.0 Job 70000.0 0.0 0.0 0.0 0.0 Supplying and fixing of Hospital Glow Letter Type Name Board (Acrylic) mentioning \\"REGISTRATION COUNTER\\" size as per specification including cost of designing, material, machine cutting & labour for mounting complete in all respect as directed by the Engineer-in-Charge. 0.0 Job 75000.0 0.0 0.0 0.0 0.0 Supplying and fixing Rain Water Harvesting System including gutters, pipes, filters, and storage tanks, machinaries, as well as installation charges etc complete as directed by the Engineer-in-charge. 0.0 Job 50000.0 0.0 0.0 0.0 0.0 Supplying Master Layout Map in vinyl printing cum pasting colored pictures, text and symbols including fixing, installing and transportation complete as per the direction of the Engineer-in-charge. 0.0 Sqm 1650.0 0.0 0.0 0.0 0.0 Providing and supplying aluminium extruded tubular and other aluminium sections as per the architectural drawings and approved shop drawings , the aluminium quality as per grade 6063 T5 or T6 as per BS 1474,including super durable powder coating of 60-80 microns conforming to AAMA 2604 of required colour and shade as approved by the Engineer-in-Charge. (The item includes cost of material such as cleats, sleeves, screws etc. necessary for fabrication of extruded aluminium frame work. Nothing extra shall be paid on this account). 0.0 Kg 338.25 0.0 0.0 0.0 0.0 Designing, fabricating, testing, protection, installing and fixing in position semi (grid) unitized system of structural glazing (with open joints) for linear as well as curvilinear portions of the building for all heights and all levels, including:(a) Structural analysis & design and preparation of shop drawings for the specified design loads conforming to IS 875 part III (the system must passed the proof test at 1.5 times design wind pressure without any failure), including functional design of the aluminum sections for fixing glazing panels of various thicknesses, aluminium cleats, sleeves and splice plates etc. gaskets, screws, toggles, nuts, bolts, clamps etc., structural and weather silicone sealants, flashings, fire stop (barrier)-cum-smoke seals, microwave cured EPDM gaskets for water tightness, pressure equalisation & drainage and protection against fire hazard including:(b) Fabricating and supplying serrated M.S. hot dip galvanised / Aluminium alloy of 6005 T5 brackets of required sizes, sections and profiles etc. to accommodate 3 Dimentional movement for achieving perfect verticality and fixing structural glazing system rigidly to the RCC/ masonry/structural steel framework of building structure using stainless steel anchor fasteners/ bolts, nylon seperator to prevent bimetallic contacts with nuts and washers etc. of stainless steel grade 316, of the required capacity and in required numbers.(c) Providing and filling, two part pump filled, structural silicone sealant and one part weather silicone sealant compatible with the structural silicone sealant of required bite size in a clean and controlled factory / work shop environment, including double sided spacer tape, setting blocks and backer rod, all of approved grade, brand and manufacture, as per the approved sealant design, within and all around the perimeter for holding glass.(d) Providing and fixing in position flashings of solid aluminium sheet 1 mm thick and of sizes, shapes and profiles, as required as per the site conditions, to seal the gap between the building structure and all its interfaces with curtain glazing to make it watertight. 0.0 Sqm 2866.1 0.0 0.0 0.0 0.0 Extra for openable side / top hung vision glass panels (IGUs) including providing and supplying at site all accessories and hardwares for the openable panels as specified and of the approved make such as heavy duty stainless steel friction hinges, min 4 -point cremone locking sets with stainless steel plates, handles, buffers etc. including necessary stainless steel screws/ fasteners, nuts, bolts, washers etc. all complete as per the Architectural drawings, as per the approved shop drawings, as specified and as directed by the Engineer- in-Charge. 0.0 Sqm 2997.6 0.0 0.0 0.0 0.0 Providing, assembling and supplying vision glass panels (IGUs) comprising of hermetically-sealed 6-12- 6 mm insulated glass (double glazed) vision panel units of size and shape as required and specified, comprising of an outer heat strengthened float glass 6mm thick hard coated low emmissivity glass, of approved colour and shade with reflective soft coating on surface # 2 of approved colour and shade, an inner Heat strengthned clear float glass 6mm thick, spacer tube 12mm wide, dessicants, including primary seal and secondary seal (structural silicone sealant) etc.all complete for the required performances, as per the Architectural drawings, as per the approved shop drawings, as specified and as directed by the Engineer-in-Charge. The IGUs shall be assembled in the factory/ workshop of the glass processor.“(Payment for fixing of IGU Panels in the curtain glazing is included in cost of item No.26.2)“For payment, only the actual area of glass on face # 1 of the glass panels (excluding the areas of the grooves and weather silicone sealant) provided and fixed in position, shall be measured in sqm.“ (i) Coloured tinted float glass 6mm thick substrate with reflective soft coating on face # 2, + 12mm Airgap + 6mm Heat Strengthened clear Glass of approved make having properties as visible Light transmittance (VLT) of 25 to 35 %, Lightreflection internal 10 to 15%, light reflection external 10 to 20 %, shading coefficient (0.25- 0.28) and U value of 3.0 to 3.3 W/m2 degree K etc. The properties of performance glass shall be decided by technical sanctioning authority as per the site requirement. 0.0 Sqm 3036.1 0.0 0.0 0.0 0.0 Providing and fixing ISI Marked insulated fire rated door confirming to IS 3614: 2021, & tested to IS17518, and shall carry a unique label with certification/test report number. The fire rating shall be for 120minutes integrity and 30minutes insulation. Material shall be galvanised steel conforming to IS 277, made out of minimum 1.2 (18 SWG) for both frame and shutter, G.I. sheet (zinc coating 120 gsm). Frame shall be 125 x 75 grooved step profile with built in rebate for fire rated smoke seal. Frame shall be mitered and field assembled. EPDM smoke seal to be provided along with frame as standard. Door shutter shall be double skin of 60mm thick step with required fire rating and insulation with vision panel. The infill material shall be high density mineral wool of minimum 120kg/sq.m3. Intumescent seal shall be provided on all around the door leaf of minimum size 15 x 1.5mm thick. All doorset shall be factory prepped for receiving appropriate hardware and provided with necessary reinforcement for hinges, locks and door closers. The door stiles should be interlocked, for pairs of doors integral astragals has to be provided on the meeting stile for both active and inactive leaf. Vision lite, minimum 5mm clear fire rated glass of size 200 x 300mm (max 0.06sq.mt) on shutter, fixing with clipon arrangement. All frame and door shutter shall be finished polyster powder coated to minimum 50microns, of approved colour as per the direction of the engineer incharge. Cost of doorset shall include following hardware and accessories as a complete assembly. SS ball bearing hinges of SS304 grade of size 100x75x3mm, 1 set Panic device for double leaf doorset and external trim with key cylinder tested as per EN1125 and CE marked. 1no Door closer per leaf with spring size of EN 3-5, as per EN1154 & CE marked,1no door door coordinator also be given in case of double leaf door. Suitable anchor fastners for fixing on different type of wall construction as per manufacturer recommendation.Once frames is installed it shall be filled with fire rated PUF. Manufacturer test certificates shall covers complete door set as a latched assembly with a valid test certificate not exceeding 5 years from the date of issue of report. for more info refer doors details drawing. Approved make : Shakti Hormann, MPP, Godrej, Promat 0.0 Sqm 23880.0 0.0 0.0 0.0 0.0 Providing and fixing of Standard Duty Hollow Metal Door Frame and Flush Door Shutter of approved make such as Shakti Hormann, conforming to IS 4351 for steel door frames and IS 2191 (Part-II) for shutters, manufactured in an ISO 9001:2015 certified facility. The door frame shall be single rebate grooved profile of size 125 x 55 mm fabricated from 1.2 mm (18 gauge) thick galvanized steel sheet confirming to IS 277, suitable for 40 mm thick shutter, with mitered corners, self-tab assembly, inbuilt groove for PVC sealing system, mortised, drilled and tapped for hardware, complete with back plate brackets, anchor fasteners for fixing in finished plastered masonry openings, filled with non-fire rated PUF and gaps sealed with silicone sealant. The door shutter shall be 40 mm thick fully flush type with tubular core chipboard infill, faced on both sides with minimum 3 mm thick calibrated pre-laminated fibre board of minimum density 850 kg/m³ in approved shade, with minimum 40 mm wide LVL rails and stiles, all edges finished with 0.8 mm thick PVC edge banding using PUR hot melt adhesive, factory pre-engineered for hardware fixing, complete with all materials, labour, transportation, fitting and fixing in position including PVC seal, approved hardware provisions and finishing in GRAINTEK texture/wood stain/powder coated finish as specified, complete in all respects as per direction of Engineer-in-Charge. 0.0 Sqm 9285.0 0.0 0.0 0.0 0.0 Providing and fixing of Sliding windows of approved make to be fabricated from roll formed sections made of pre-painted steel (base steel as per IS-513 of 0.6 mm thick \\"D\\" quality, galvanized as per IS-277 with zinc of 120 Gm/Sq.mtr) with total coated thickness of 0.55 mm Slide guide section should be made of 0.5 mm stainless steel of 430 grade. with paint specification being with primer of 5-7 microns thick and finished paint with polyster paint (Black /Pearl white/ Chocolate Brown) of 12-16 microns along with the alkyd backer at the back of 5-7 microns and the Sections for external frame bottom and top should be of 79 x 45 mm. external frame sides should be of 69 x 24 mm, guide for top and bottom should be of 69 x 26 mm (Stainless Steel). Section for shutter should be of 26 x 30 mm, Sash bar should be of 23 57mm.Accessories / gaskets are to be used as per the manufacturer's supply and specification like gasket will be made of EPDM. All corner brackets for internal and external are to be made of glass filled nylon. The sections are to be cut to length joined and assembled by means of corner bracket and frames are fixed to the concrete/masonry walls by means of self expanding screws and glass to be used of 5 mm reflective with all taxes complete. 0.0 0.0 0.0 0.0 0.0 0.0 Ground Floor 0.0 Sqm 6486.1 0.0 0.0 0.0 0.0 First Floor 0.0 Sqm 9810.7 0.0 0.0 0.0 0.0 Second Floor 0.0 Sqm 9810.7 0.0 0.0 0.0 0.0 Third Floor 0.0 Sqm 9810.7 0.0 0.0 0.0 0.0 Fourth Floor 0.0 Sqm 9810.7 0.0 0.0 0.0 0.0 Fifth Floor 0.0 Sqm 9810.7 0.0 0.0 0.0 0.0 SiXth Floor 0.0 Sqm 9810.7 0.0 0.0 0.0 0.0 Add for plaster drip course/ groove in plastered surface or moulding to R.C.C. projections. 0.0 0.0 0.0 0.0 0.0 Ground Floor 0.0 Rmt 43.8 0.0 0.0 0.0 0.0 First Floor 0.0 Rmt 43.8 0.0 0.0 0.0 0.0 Second Floor 0.0 Rmt 43.8 0.0 0.0 0.0 0.0 Third Floor 0.0 Rmt 43.8 0.0 0.0 0.0 0.0 Fourth Floor 0.0 Rmt 43.8 0.0 0.0 0.0 0.0 Fifth Floor 0.0 Rmt 43.8 0.0 0.0 0.0 0.0 SiXth Floor 0.0 Rmt 43.8 0.0 0.0 0.0 0.0 |
| 115 | Providing and fixing barbed wire fencing on R.C.C. (1:2:4) fencing posts with chips 1.68M long, 13cm x 13cm at bottom and 8cm x 8cm at top and 30cm 30cm x 8 cm at base finished smooth at spacing of 2.0m c/c , fixing with G.I. barbed wire both in horizontal and in diagonal by means of staples and staining hooks and tying with G.I wire including cost of barbed wire, staples, hooks, tying wires and labour, post etc complete in all respect as per the direction of the Engineer-in-charge. |
| 116 | Supplying and fixing of Elastomeric Membrane of 200mm x 2mm size for expansion joint sealing from approved manuefacturer, fixing with epoxy adhesive of approved quality complete. |
| 117 | Supplying and fitting -fixing of Un-plasticised poly Vinyl Chloride (UPVC) (FENESTA/NCL VECCA LTD) Ventillator/Top Hung-60 Series duly manufactured using UPVC reinforced Profiles of 60mmx 55mmx2.5mm for outer frames ,75mmx60mmx2.25mm for casement window sash profile capable of mounting single glazing system,structurally reinforced with hot dip galvanised upto 50 microns of minimum thickness of 1.5 mm prefabricted and welded through fusion welding the wwindow sash shall be fitted with 6mm thick clear toughened glass of Saint-Gobain make duly fixed with EPDM weathering seal resistant accessories like clipping locking system made of aluminium 1 no per set of sashes and the system to be installed at the site using anchor fasteners,silicon rubber sealant,easy glazing/deglazing at siteetc including cost and conveyance of all accessories labour charges,materials and product confirming to ASTM D 638-14,EN-477-95 and other applicable codes and standards. Providing and fixing of 12mm thick Clear Toughened Glass Frameless Door WithDorma Premium Fittings.Dorma Premium (9111198) Unilite Package BTS 75,UL PT 10with Cover,UL PT 20 with Cover, UL US 10 Luck with Cover and PT 24,Dorma Premium(9137121) H Type Handle 450mm,12mm Clear Toughened Glass with Cutout and Hole.including the cost of all materials, hardware fittings, cost of all labour, conveyance,loading, unioading, T&P, etc, complete as per the direction of Engineer-in-Charge. 0.0 0.0 Earth Filling foundation and plinth-construction of embankment with earth approved material obtained from borrowpits, transporting to site, spreading, grading to required slope and compacting to meet requirement of table 300-2. 0.0 0.0 Cum 203.9 0.0 Supplying and fixing Rain Water Harvesting System including gutters, pipes, filters, and storage tanks, machinaries, as well as installation charges etc complete as directed by the Engineer-in-charge. 2.0 2.0 Each 50000.0 100000.0 TOTAL SUPER STRUCTURE 31100430.52299455 Total 42414290.08405705 1058094.0725 3237986.9964 37196458.074257046 B SOLAR Solar System 41688620.24015705 Supply Installation Testing and Commissioning of on grid Solar Photovoltaic Power Plant conforming to MNRE specifications as amended, consisting of Mono / Poly Crystalline silicon solar cells, net metering facility ,necessary protections, earthing, mounted on Aluminium / GI structure of suitable strength with following components a complete aas arequired: a) Solar Photovoltaic Module of capacity 330Wp or above, manufactured in India, conforming to IS14286 / IEC61215, IS/IEC61730-Part-1,IS/IEC61730-Part-2. Solar Photovoltaic Module conversion efficiency shall not be less than 16.5%. PV modules used in solar power plants /systems must be warranted for their output peak watt capacity, which should not be less than 90% at the end of 10 years and 80% at the end of 25 years. b) Power Conditioning Unit (PCU) of 350-800 V DC Input voltage range and 400 V AC, three phase , 4 wire, 50Hz +/- 2.5Hz, output voltage suitable to generate AC Power with efficiency not less than 97%, total harmonic distortion less than 3% and suitable for ambient temperature from 0 to 50 degree Celcious. The PCU shall adjust the voltage and frequency level to suit the Grid Voltage,frequency. c) Data Monitoring System complete with accessories.d)Fixing of Array junction box & Main junction box with IP 65 protection and termination arrangement for incoming and outgoing cable along with glands, lugsand other accessories etc. asarequired.e) Lightning and surge voltage protection. f) Connections & Interconnections by supplying & fixing required size XLPE insulated copper conductor 1.1 kV grade armoured power and control cables between solar modules, main power cable to grid supply PCU unit along with supplying & fixing of necessary channel/ conduit lugs and other accessories etc. asrequired. with all required accessories as required as per the direction of Engg-in-charge.Make-Kamal Solar/ EMMVEE/ Venus / Anchor/panasonic or equievalant reputed make & model A catogory, ISI marked as approved . The entire SOLAR system should be Replacement Warranty will be 5 years 5.0 kw 60500.0 302500.0 Total Solar 302500.0 C FIRE FIGHTING FIRE EXTINGUISHERS Providing and Fixing ISI marked ABC stored pressure type Fire extinguisher of 6 Kgs. Capacity confirming to IS: 15683 with discharge hose, nozzle, Mono Amonium Phosphate base & ABC powder pressurised with nitrogen gas carrying handle and wall mounting bracket etc as required with 5 Years maintenace. 4.0 No 5590.0 22360.0 SAFEGUARD , INTIME , FIRESHIELD 0.0 Providing and Fixing of 4.5 Kgs. Capacity CO2 gas type ISI marked fire extinguisher (IS: 15683) fitted with high pressure 1 mtr. Long discharge hose & horn complete with refill gas, carrying handle and wall mounting bracket etc as required with 5 Years maintenace. 2.0 No 13260.0 26520.0 Providing and Fixing of of 2 kG capacity Eco Friendly, Stored pressure type filled with HFC 134 A ( clean agent fire extinguishant having Zero Ozone depletion potential ) Clean Agent Fire Extinguishers with safety seal, pressure guage, controllable discharge mechanism, helium leak detection tested and conforming to IS 15683 complete with initial charge as required with 5 Years maintenace. 2.0 No 20280.0 40560.0 Fire buckets 3 nos round bottom type enamel painted, white inside & Red out side and Letter \\"FIRE\\" in black out side and handle with mounting bracket and Fire bucket stand fabricated by MS angles with 5 Years maintenace.Make:FABRICATED 1.0 Set 7605.0 7605.0 SIGNAGES 0.0 Floor identification signage (i.e, GROUND FLOOR… ETC.,) at each stair enclosure on every floor, indicating the floor number in words, lettering size shall be 7.5cm with contrasting colour from back ground. Size shall be 15cm * 60cm. 3.0 No 975.0 2925.0 Fire Exit signage at each stair on every floor, indicating the direction of fire exit, lettering size shall be 7.5 cm with contrasting color from back ground. Size shall be 15cm x 60cm. 3.0 No 715.0 2145.0 Total Fire Etinguishers 102115.0 D LANDSCAPING AND HORTICULTURE (a) Grass |
| 118 | Providing and fixing Neelgiri/Mexican grass turf with earthy 50mm to 60mm thickness of existing ground prepared with proper level and ramming with required tools wooden (Dhurmos) and than rolling the surface with light roller make the surface smoothen and light, watering with sprinkler and maintenance for 30 days or more till the grass establish properly as per direction of officer incharge. B. SITE PREPARATION 0.0 |
| 119 | Supplying and stacking of good earth at site including royalty and carriage upto 5 km complete (earth measured in stacks will be reduced by 20% for payment). |
| 120 | Supplying and stacking sludge at site including royalty and carriage upto 5 km complete (sludge measured in stacks will be reduced by 8% for payment). |
| 121 | Supplying and stacking at site dump manure from approved source, including carriage upto 5 km complete (manure measured in stacks will be reduced by 8% for payment) . Screened through sieve of I.S. designation 20 mm 8.333333333333332 Cum 239.6 1996.6666666666663 Screened through sieve of I.S. designation 16 mm 8.333333333333332 Cum 267.0 2224.9999999999995 Screened through sieve of I.S. designation 4.75 mm 8.333333333333332 Cum 288.9 2407.4999999999995 |
| 122 | Spreading of sludge, dump manure and/or good earth in required thickness as per direction of officer-in-charge (cost of sludge, dump manure and/ or good earth to be paid separately). |
| 123 | Mixing earth and sludge or manure in the required proportion specified or directed by the Officer-in-charge. PLANTATION 0.0 Supply & planting of the tree as per botanical name / common name & specification mentioned here under : 0.0 |
| 124 | Tree Providing and stacking of Tecoma argentea of height 120-135 cm. in big poly bag of size 25 cm as per direction of the officer-in-charge 10.0 Each 121.43100000000001 1214.3100000000002 Providing and stacking of Saraca indica (Sita Ashok) of height 105-120 cm. in big poly bags of size 25 cm as per direction of the officer-in-charge 10.0 Each 121.43100000000001 1214.3100000000002 Providing and stacking of Polyalthia pendula (Ashok Pendula) of height 180-195 cm. in gunny bag of size 30 cm as per direction of the officer-in-charge. 10.0 Each 151.793 1517.93 Providing and stacking of Plumeria alba dwarf dwarf of height 90-105 cm. with 3-4 branches and thick stem in big size HDPE bags as per direction of the officer-in-charge. 10.0 Each 1138.388 11383.88 Providing and stacking of Plumeria rubra of height 120-150 cm. with 3-4 branches and thick stem in big size HDPE bags as per direction of the officer-in-charge 10.0 Each 606.9 6069.0 Providing and stacking of Mimusops elengi (Maulsri) of height 180-195 cm., well developed with thick stem in big in big size HDPE bag as per direction of the officer-in-charge 10.0 Each 189.737 1897.37 Providing and stacking of Foxtail palm of ht. 240-270 cm bottom girth 35- 40 cm well developed in big size HDPE bags as per direction of the officer-in-charge. 10.0 Each 986.612 9866.119999999999 |
| 125 | Ground cover Providing and stacking of Duranta Golden, having ht.15 to 20 cm bushty shape with fresh and healthy leaves in 15 cm size of Earthen Pot/Plastic Pot & as per direction of the officer-in-charge 10.0 Each 30.362 303.62 Providing and stacking of Alternanthera species of height 15 cm to 20 cm, full of branches and foliage in 15 cm size of Earthen Pot/Plastic Pot & as per direction of the officer-in-charge. 10.0 Each 30.362 303.62 Providing and stacking of Daniella variegated, with 3 to 4 variegated leaves in 20 cm size of Earthen Pot/Plastic Pot & as per direction of the officer-in-charge 10.0 Each 30.362 303.62 Providing and stacking of Clerodendrum inerme having ht. 25 cm to 30 cm multi branched in 20 cm size of Earthen Pot/Plastic Pot & as per direction of the officer-in-charge 10.0 Each 15.181 151.81 |
| 126 | Shrurbs Providing and stacking of Ficus reginald well branched, bushy of height 60- 75 cm. in earthen pots of size 25 cm as per direction of the officer-in-charge. 8.0 Each 151.793 1214.344 Providing and stacking of Euphorbia caracasana (bronze colour leaves) of height 90-105 cm., bushy in big size HDPE bag as per direction of the officer-in-charge. 8.0 Each 159.375 1275.0 Providing and stacking of Chandni dwarf of height 15-20 cm., well branched in earthen pots of size 20 cm as per direction of the officer-in-charge. s per direction of the officer-in-charge. 8.0 Each 53.125 425.0 Providing and stacking of Thuja compacta of height 45-60 cm., well branched in earthen pots of size 25 cm as per direction of the officer-in-charge 8.0 Each 98.66799999999999 789.3439999999999 |
| 127 | Medicinal plant Providing and Stacking of Curry leaf of height 75-90 cm in poly bag of size 25 cm as perdirection of the officer-in-cha 10.0 Each 113.83199999999998 1138.3199999999997 Providing and Stacking of Adusha of ht. 30 cm with multi branches in Poly bag of size 20 cm. as per direction of the officer-in-charge. 10.0 Each 45.543 455.43 Providing and Stacking of Aprajita Blue well developed in poly bag of size 20 cm as per direction of the officer-in-charge 10.0 Each 45.543 455.43 Providing and Stacking of Peepli well developed in poly bag of size 20cm as per direction of the officer-in-charge. 10.0 Each 45.543 455.43 Providing and Stacking of Shivnath well developed in poly bag of size 20 cm as per direction of the officer-in-charge. 10.0 Each 60.707 607.07 Providing and Stacking of Marwa Dona of ht. 30cm with multi branches in Poly bag of size 20 cm.as per direction of the officer-in-charge 9.0 Each 45.543 409.887 Providing and Stacking of Nirgundi well developed in poly bag of size 20 cm as per direction of the officer-in-charge 10.0 Each 45.543 455.43 Providing and Stacking of Ficus panda plant of height 90 -105 cm. multibranches, well developed in poly bags of size 25 cm as per direction of the officer-in-charge. 10.0 Each 242.86200000000002 2428.6200000000003 Providing and stacking of Mimusops elengi (Maulsri) of height 180-195 cm., well developed with thick stem in big in big size HDPE bag as per direction of the officer-in-charge 10.0 Each 237.17125 2371.7124999999996 Ornamental 0.0 Providing and Displaying Travelers palm well developed with fresh & healthy foliage 120 to 150 cm ht. in 35 cm Cement Pot as per direction of the officer-in-charge. 4.0 Each 735.93 2943.72 Providing and Displaying Ficus reginold Topiary well developed with fresh & healthy 6 to 7 big ball specific size 210 to 240 cm ht in 45 cm Cement Pot as per direction of the officer-in-charge 4.0 Each 3102.5 12410.0 Providing and Displaying Mascarena palm well developed with fresh & healthy foliage leaves 150 to 180 cm ht in 35 cm Cement Pot as per direction of the officer-in-charge 4.0 Each 2800.4464285714284 11201.785714285714 Providing and Displaying Cycus cirsnallis well developed with fresh & healthy 35 to 40 lush green leaves in 40 cm Cement Pot as per direction of the officer-in-charge. 4.0 Each 2956.028 11824.112 Holes 90 cm dia, and 90 cm deep 70.0 Nos 119.6 8372.0 Holes 45 cm dia, and 45 cm deep 177.0 Nos 15.8 2796.6 |
| 128 | Nilkamal Plastic Manual-Lift Wheel Garbage Dustbin (Green, Blue, 60 L) Total Landscape- 530835.8831209524 Total Civil Work 43349740.967178 Name of the work- Construction Of Godabarish Mishra Adarsh Prathamik Vidyalaya At UGHS Kongra, Jharigam Block, Chaklapadar(GP), Nabarangpur District (Phase-II) A. INTERNAL P.H. & SANITARY WORK Sl. No. Description of work Qnty. Unit Rate Amount Rs. |
| 129 | Providing and fixing Clorinated Polyvinyl Chloride [CPVC] pipes SDR-11 conforming to IS:15778, having thermal stablity for hot & cold water supply , including all CPVC plain & brass threaded fitting including fixing the pipe with clamps at 1.00m spacing . This includes jointing of pipes and fittings with one stp CPVC solvent cement and testing of joints complete as per specification and direction of Enfineer-in-charge. 20 mm PVC sch-80 pipes 70.0 Mtr 307.6 21532.0 25 mm PVC sch-80 pipes 70.0 Mtr 426.8 29876.0 32 mm PVC sch-80 pipes 100.0 Mtr 587.2 58720.00000000001 50 mm PVC sch-80 pipes 120.0 Mtr 1201.5 144180.0 |
| 130 | Supplying all materials,labour and T&P for cutting holes through existing brick work including making good to the same in cement mortar(1:4) for taking G.I. pipes and fittings /P.V.C. pipes and fittings all complete as per specification. 250mm Thick 38.0 Each 68.1 2587.7999999999997 |
| 131 | Supplying all materials,labour and T&P for cutting holes in R.C.C. floors and roofs up to 19 cm. thick including for passing GI / PVC pipes and fittings etc. and repairing the holes after insertion of pipes etc. with cement concrete 1:2:4 including finishing complete to make it leak proof leak to the damages all complete as per specification and direction of the Engineer-in-charge. 7.0 Each 219.6 1537.2 |
| 132 | Supplying all materials,labour and T&P for cutting groves in pucca floor and walls for taking G.I. pipes and fittings /P.V.C. pipes and fittings and making good to the damages all complete as per specification. 70.0 Mtr 283.2 19824.0 |
| 133 | Supplying all materials, labour T&P and fitting and fixing brass/CP fittings of the following nominal bore with supply of all joiniting materials complete as per specification and direction of the Engineer-in-charge. a) Supplying all labour and T&P for fixing 2 in 1 bib cock of the following size as per specification all complete. 16.0 Each 1308.3 20932.8 b) Supplying all labour and T&P for fixing long body bib cock of the following size as per specification all complete.15mm Dia 4.0 Each 1078.2 4312.8 c) Supplying all labour and T&P for fixing CP Angular stop cocks polished bright confirming to IS:781-1995 of the following nominal sizes as per specification all complete. 15mm Dia 28.0 Each 937.6 26252.8 d) Supplying fitting fixing of C.P Pillar Taps highpressure lettered Hot and cold with long screws shanks and back nuts of the following nominal bore as per specification. (Make-Somany/Cera/Hindware) 15mm Dia 17.0 Each 1475.0 25075.0 e) Supplying all labour and T&P for fixing CP short body Bib cock [taps] polished bright confirming to IS:781-1995 of the following nominal sizes as per specification all complete . 3.0 Each 915.5 2746.5 f) Supplying all labour and T&P for fixing U.P.V.C Ball valve [ horizontal plungr type] confirming to IS:1703-1977 of the following nominal sizes as per specification all complete. ) 25mm Dia 6.0 Each 687.1 4122.6 g) Supplying all labour and T&P for fixing U.P.V.C Ball valve [ horizontal plungr type] confirming to IS:1703-1977 of the following nominal sizes as per specification all complete. 32mm Dia 4.0 Each 1421.6 5686.4 h) Supplying all labour and T&P for fixing U.P.V.C Ball valve [ horizontal plungr type] confirming to IS:1703-1977 of the following nominal sizes as per specification all complete. 50mm Dia 2.0 Each 3125.1 6250.2 i) Providing and fixing C.P. Brass Extension Nipple 1 inch with extension piece as per direction of Engineer-in-charge. 15.0 Each 594.39 8915.85 j) Supplying fitting fixing of CP waste of the following noninal diameter for wash hand basin and sink as per specification. 14.0 Each 380.1 5321.400000000001 k) Supplying all materials,labour and T&P for fixing CP Gratings of the following nominal diameter of outlet, of self cleaning design with sand cast iron screwed down or hinged grating with or without vent arm including cutting and making good to the walls and floors etc. all complete as per specification. 38.0 Each 1190.4 45235.200000000004 l) Providing and fixing of approved make and model for Chrome plated Grab Bar,for Physically challenged toilet, The work shall include the cutting of walls or floors & making good, complete as per direction of Engineer in Charge. 0.0 Each 4387.44 0.0 |
| 134 | Supplying fitting fixing of C.P health facuet high pressure lettered Hot and cold with long screws shanks and back nuts of the following nominal bore as per specification. 15mm dia CP Health Faucet of 1mtr long PVC tube 8.0 Each 809.8 6478.4 |
| 135 | Providing and fixing of Rational moulded polyethylene cylendrical vertical water storate tanks confirming to IS:12701-1996 including cutting holes through the tank and fixing mild steel tubes and fittings and proviidng extra sockets and jam nuts , fixing ball volve ete. including hoisting up to a hite of 5.00metes above ground level and placing the tank to the required position etc. all complete as per specification and direction of the engineer-in-charge. i) Overhead water storage tanks 8000.0 Lit. 13.59424 108753.92 ii) Extra over item no.3.1.8 for hoisting Rational moulded polyethylene cylendrical vertical water storage tanks of following sizes for every additional height of 5.00m. Or part thereof complete as per specification and direction of the engineer-in-charge. Water storage tanks 4.0 Each 1248.0 4992.0 |
| 136 | Supplying all materials, labour, T&P and fitting and fixing U-PVC SWR soil waste ventilating pipes and fittings of the following outside diameter conforming to ISI No 13592/1992 to walls with nails, bobbins and wooden plugs or laying in trenches including jointing with supply of approved rubber lubricant by non-heat application method/as per manufacturer's specification, testing, earthwork in excavation in all kinds of soil and refilling of trenches as per specification and direction of the Engineer-In-Charge. 110mm diameter PVC SWR pipes 104.0 Mtr 391.3 40695.200000000004 75mm diameter PVC SWR pipes 89.0 Mtr 242.9 21618.100000000002 110mm PVC door Tee 11.0 Each 388.6 4274.6 75mm PVC door Tee 5.0 Each 293.0 1465.0 110mm PVC offset 10.0 Each 138.0 1380.0 110mm PVC door bend 10.0 Each 216.4 2164.0 75mm PVC door bend 10.0 Each 114.1 1141.0 110mm PVC plain shoe bend 10.0 Each 170.8 1708.0 75mm PVC plain shoe bend 10.0 Each 83.2 832.0 110mm PVC vent cowl 10.0 Each 86.6 866.0 75mm PVC vent cowl 0.0 Each 73.0 0.0 110mm S-trap 11.0 Each 629.7 6926.700000000001 110mm P-trap 1.0 Each 348.2 348.2 110mm SWR Pipe Clip 105.0 Each 30.4 3192.0 75mm SWR Pipe Clip 90.0 Each 23.4 2106.0 110/75 mm Dia Reducer/Connector 5.0 Each 258.5 1292.5 90mm Nahani Trap 33.0 Each 145.6 4804.8 |
| 137 | Supplying all materials,labour and T&P for fixing of PVC 10 ltr capacity low level flushing cistern with manually controlled device[handle cover] confirming to IS 7231 with fittings and fixtures etc. all complete as per specification. 10 Liters capacity PVC cistern 16.0 Each 1954.3 31268.8 |
| 138 | Supplying all materials,labour and T&P for fixing water closet ,squatting pan(Indian type.W.C.pan or Orissa pan) confirming to IS 2556 : Part-3-2004 duly embedded in cement concrete (1:4:8) using 40mm.nominal size h.b.g. chips [including foot rest for I.W.C. and trap] all complete as per specificationand directon of theEngineer - in - charge. 8.0 Each 3837.7 30701.6 |
| 139 | Supplying all materials,labour and Supplying all materials,labour and T&P for fixing in cement mortar (1:3) a pair of white vitereous china (250x130x30mm.) foot rest for squatting water closet. etc. all complete as per specificationand direction of the Engineer-in-charge. 8.0 Pair 560.9 4487.2 |
| 140 | Supplying all materials,labour and T&P for Supplying all materials,labour and T&P for fixing wash down water closet (European type W.C.) with integral \\"S\\" or \\"P\\" trap tothe floor with wooden plug and chromium plated screw including jointing the trap with soil pipe in cement mortar (1:1) etc. all complete as per specification. 7.0 Each 3175.6 22229.2 |
| 141 | Supplying all materials,labour and T&P for fixing plastic seat and cover for wash down water closet with chromium plated brass hinges and rubber buffers all complete as per specification. 7.0 Each 923.4 6463.8 |
| 142 | Supplying all materials,labour and T&P for fixing wash hand basin (SS Made) with hole for pillar taps confirming to IS 2556:part4-2004 with cast iron /M.S. brackets painted white including cutting holes in walls and making good to the damages etc. all complete as per specification. 11.0 Each 4599.3 50592.3 |
| 143 | Supplying all materials,labour and T&P for fixing corner wash hand basin with hole for pillar taps confirming to IS 2556:part4-2004 with cast iron /M.S. brackets painted white including cutting holes in walls and making good to the damages etc. all complete as per specification. 4.0 Each 2666.6 10666.4 |
| 144 | Supplying all materials,labour and T&P for fixing Pedestal for wash hand basin complete recessed at the back for the receiptionof pipe and fittings etc. all complete as per specification including cost of pedestal for wash basin 4.0 Each 2621.9 10487.6 |
| 145 | Supplying all materials,labour and T&P for fixing of 600x450 bevelled edge mirror of superior glass mounted on 6mm thick ac sheet or ply wood sheet and fixed to wooden plugs with chromium plated brass screws and washers etc. All complete as per specification . 600mmx450mm size B.E.mirror 12.0 Each 2167.7 26012.399999999998 |
| 146 | Supplying all materials,labour and T&P for fixing standard size glass self with chromium plated brass brackets fixed to wooden plugs with chromium plated brass screws and washers etc. all complete as per specification. 13.0 Each 801.7 10422.1 |
| 147 | Supplying all materials,labour and T&P for fixing standard size C. P. towel rail fixed with chromium plated brass brackets fixed to wooden plugs with cromium plated brass screws complete as per specification. 8.0 Each 1080.1 8640.8 |
| 148 | Supplying all materials,labour and T&P for fixing of cromium plated brass soap dish complete with chromium plated brass brackets fixed to wooden plugs with chromium plated brass screws as per specification. 16.0 Each 354.4 5670.4 |
| 149 | Supplying all materials,labour and T&P for fixing standard size C. P. towel ring fixed fixed to wooden plugs with cromium plated brass screws complete as per specification. |
| 150 | Supplying all materials,labour and T&P for fixing of liquid soap container - glass container or plastic container with chromium plated brass lid and brackets fixed to wooden plugs with chromium plated brass screws as per specification. |
| 151 | Supplying all materials,labour and T&P for fixing stainless steel AISI 304 [18/8] Kitchen sink as per IS 13983 with cast iron bracet and stainless steel plug including painting of fittings and brackets ,cutting and making good to the walls etc. all as per specification including cost of sink with all accessories. 2.0 Nos 6159.2 12318.4 |
| 152 | Supplying fitting fixing of cromium plated CP over head shower rose with arm including polishing and complete as per specification and direction of the Engineer in charge. |
| 153 | Supplying all labour and T&P for fixing CP Concealed stop cocks polished bright confirming to IS:781-1995 of the following nominal sizes as per specification all complete. |
| 154 | Supplying all materials,labour and T&P for fixing Porcelain Urinal respectively with waste pipe by means of white lead mixed with chopped hemp etc. all complete as per specification. |
| 155 | Supplying all materials,labour and T&P for fixing Drinking Water Purifier Stall Type etc. all complete as per specification. |
| 156 | Fixing standard size Chromium Plated brass or glazed porcelain Toilet paper holder fixed to woden plugs with Chromium Plated brass screws complete as per specification and direction of the Engineer in charge. 0.0 |
| 157 | Supply and fixing of Geyser 2000 Watt (10 Lit.) of approved brand complete as per specification and direction of the Engineer in charge. 0.0 |
| 158 | Supplying fitting fixing of cromium plated CP Wall Mixture 2 in 1 with out Telephonic Shower with arm including polishing and complete as per specification. |
| 159 | Providing and fixing approved quality E.W.C. Matrix Set comprising European Water Closet (E.W.C.), low/high level cistern, wash basin and sanitary fittings such as bottle trap, pillar cock, toilet paper holder, towel rail, soap case, mirror, etc., including grab bar set for Accessible/Handicap Toilet consisting of stainless steel grab bars and support fittings required for differently-abled users, conforming to universal accessibility standards. The set shall include wall-mounted horizontal and vertical support bars near the W.C. and wash basin area, made of SS 304 grade stainless steel with satin/matt finish, complete with necessary brackets, anchor fasteners, screws, bends, end caps and all accessories. The arrangement shall ensure safe support and ease of movement for wheelchair users and physically challenged persons. The work shall include proper fixing, alignment, levelling and positioning as per approved drawings, CPWD/IS accessibility guidelines and directions of the Engineer-in-Charge, complete in all respects. B. EXTERNAL P.H. & SANITARY WORK |
| 160 | Supplying all materials, labour, T & P and constructing Gully trap chamber of the following inside size with 8 cm thick R.C.C. precast cover slab in CC (1:2:4) mix using 12mm size h.g. chips, foundation concrete (1:4:8) using 40mm size h.g. metal on bed aound trap , Fly Ash brickwork in CM (1:6) in P&F and inside 12mm thick cement plastering (1:3) finished with a floating coat of neat cement including fixing 100mm x100mm size gully trap, 150mm x150mm C.I gratig etc. all complete as per aproved drawing, specification and direction of Engineer-in-charge. 250mmx250mm with RCC cover 8.0 Each 1745.0 13960.0 |
| 161 | Constructing inspection chamber with R.C.C top slab in (1:2:4) mix, foundation concrete (1:3:6), inside plaster 12mm thick with cement mortar (1:3) finished with neat cement punning, 12mm thick outside cement plaster (1:3), brick work with K.B bricks having crushing strength not less than 75kg/cm² with dimensional tolerance ± 8 percent in cement mortar (1:5), cement concrete (1:2:4) finished smooth using 12mm size h.g chips, earthwork in excavation in all kinds of soil and refilling the cavity around the chamber complete as per specification. Inspection Chamber inside size 750mm x 750mm and 450mm 8.0 Each 13640.0 109120.0 |
| 162 | Supplying all materials,labour and T&P for laying in trenches unplasticized PVC pipes and specials of the following outside dia. for all classes including jointing with approved solvent cement by non-heat application method including testing as per specification and direction of Engineer-in-charge etc. all complete. [including earth work and cost of pipes. a) 110 mm dia U-PVC pipes Class-3 90.0 mtr 1012.3 91107.0 b) 160 mm dia U-PVC pipes Class-3 45.0 mtr 2182.2 98198.99999999999 |
| 163 | Constructing manholes with R.C.C top slab in (1:2:4) mix, foundation concrete (1:3:6), inside plaster 12mm thick with cement mortar (1:3) finished with neat cement punning, 12mm thick outside cement plaster (1:3), brick work with K.B bricks having crushing strength not less than 75kg/cm² with dimensional tolerance ± 8 percent in cement mortar (1:5), cement concrete (1:2:4) finished smooth using 12mm size h.g chips, earthwork in excavation in all kinds of soil and refilling the cavity around the chamber complete as per specification. a) Plain Manholes inside size 900mm x 800mm and 450mm deep 8.0 each 18165.1 145320.8 |
| 164 | Construction of 50 Users Septic Tank (2 No.s) a)-i Earth work in excavation in foundation trenches, column foundation, pit, etc in all kind of soil including moorum stony earth and earth mixed with boulders except sheet rock and boulders not requiring blasting including dressing of sides and levelling the bed up to the required depth and depositing the excavated materials away from the work site with initial lead of 50 mtr and all lifts, including shoring, shuttering & dewatering (if required) with cost of labour, labour cess, hire & running charges of all machineries, sundries & T&P required for the work complete as directed by the Engineer in charge. 56.879999999999995 Cum 282.9 16091.351999999997 a)-ii Above 1.5mt. Depth 47.568000000000005 Cum 305.36 14525.364480000002 b) Filling the Plinth with excavated materials (excluding rock), in layers not exceeding 0.225 m in depth including cost of watering, ramming, dressing and levelling the top to proper level & gradient, cost of labour, conveyance, loading, unloading, T&P, etc, all complete as per the direction of Engineer-in-Charge. 70.711296 Cum 157.2 11115.8157312 c) Supplying and Filling with Sand in Foundation and Plinth in layers not exceeding 20 cm in depth, well watered and compact , top surface dressed and levelled to proper level and gradient including cost of all materials , conveyance, royalties, loading, unloading, cost of all labour, T&P, etc.All compelete as per the dirrection of Engineer-in-charge. 2.958 Cum 817.6 2418.4608000000003 d) Providing and lying Plain Cement Concrete of proportion (1:4:8) in foundation & floor using 40 mm & down grade black hard crusher broken granite stone metal, washed and screened sharp sand of approved quality from approved quarry including hoisting, lowering, laying the concrete, ramming, watering and curing etc. complete to required thickness including cost of all materials, conveyance, loading, unloading, royalties, taxes, cost of labours, T&P, hire & running charges of concrete mixer, etc. all complete as per the direction of the Engineer -in -charge. 2.958 Cum 5826.3 17234.1954 e) Providing and lying Plain Cement Concrete of proportion (1:3:6) in foundation & floor using 40 mm & down grade black hard crusher broken granite stone metal, washed and screened sharp sand of approved quality from approved quarry including hoisting, lowering, laying the concrete, ramming, watering and curing etc. complete to required thickness including cost of all materials, conveyance, loading, unloading, royalties, cost of labours, T&P, hire & running charges of concrete mixer, etc. all complete as per the direction of the Engineer -in -charge. 3.9240000000000004 Cum 6220.7 24410.026800000003 f) Providing 12mm thick cement plaster in cement mortar (1:4) with neat cement punning including racking out joints, scraping and cleaning the surface and finishing the plaster surface smooth using wooden floats, bars, etc only to proper plumbs and level and making grooves, beads and drip coarse to give required ornamental finish as per drawings including cost of all materials, conveyance, loading and unloading, taxes, royalties, cost of all labour, scaffolding, staging, watering before plastering and curing, sundries and T&P, etc. complete as per direction of the Engineer-in-charge. 15.840000000000002 Sqm 215.2 3408.768 g) Providing, lifting, hoisting and laying in position machine batched , machine mixed and machine vibrated design mix cement concrete of M-25 Including the cost of Centering and Shuttering (minimum cement content not less than 403 Kg/Cum) grade in reinforced cement concrete structural elements using black hard crusher broken granite chips of approved quality from approved quarry including mixing and compacting to proper shape and size, level and plumbs and finishing the exposed surfaces smooth including the cost of all materials, cost of labour, conveyance,loading, unloading, royalties, watering and curing for the required period, T&P , hire & running charges of concrete mixer and vibrator, cost of Admixtures in recommended proportions ( as per IS 9103 ) to accelerate, retard setting of concrete, improve workability without impairing strength and durability etc. complete as per the direction of the Engineer-in-charge but excluding the cost of steel reinforcement. i. Base 5.466 Cum 7060.1 38590.5066 ii. Slab 4.644 Cum 12838.9 59623.8516 iii. Wall 21.333 Cum 12123.1 258622.0923 h) Providing & fixing TOR Fe-500 HYSD Reinforcement bars of required diameter and approved quality for Reinforced Cement Concrete work including straightening, cutting, bending, binding, welding(if approved) , joining (if necessary), tying the grills, hoisting, lowering and placing in position as per the approved design & drawings (BBS) with provision of standard fan hooks including the cost of all materials, cost of all labour, conveyance, loading, unloading, cost of binding wires of 18 to 20 gauge, T&P, etc, all complete as per the direction of Engineer-in-Charge.Note: (Linear measurements will be taken & quantity will be calculated on standard weight. Lap length of bars & Weight of binding wire will not be considered for measurement and payment). 42.448049999999995 Qtl. 9294.3 394524.9111149999 i) Supplying all materials, labour, T&P and making MS step iron in 20mm diameter MS steel bars and fixing into walls of man hole/septic tank duly embedded in cement concrete (1:3:6) complete as per specification and direction of the Engineer in charge. 4.0 Each 160.1 640.4 j) Supplying all materials, labour, T&P and laying in trenches ( to level or slope ) and jointing with provision of stiff mixture of cement mortar in proportion of 1:1 for salt glazed stoneware pipes, Grade—A of the following internal diameters including testing of pipes and joints complete. 110mm diameter UPC pipe 12.0 Mtr 1012.3 12147.599999999999 |
| 165 | Constructing RCC soak way pit with R.C.C top slab in (1:2:4) mix, inside plaster 12mm thick with cement mortar (1:3) finished with neat cement punning, 12mm thick outside cement plaster (1:3), brick work with K.B bricks having crushing strength not less than 75kg/cm² with dimensional tolerance ± 8 percent in cement mortar (1:4), cement concrete (1:2:4) finished smooth using 12mm size h.g chips, complete as per specification. a) RCC soak way pit of size 1.5m x 1.8m deep 10.0 each 10046.8 100468.0 Borewell Supplying all materials,labour T&P and providing fitting submersible pump with squarrel cage inspection type submerssible type submersible electric motor to run on 3 phase/1 phase line voltage rangingfrom 320 volt to 450 volt conforming to IS :8034/89 a One no. 3 phase 2 H.P 3 stage head range 30 to 54 mtr. Discharge 155 to 200 LMP with outlate dia 32mm. 1.0 Set 19850.0 19850.0 b 2.5 Sq mm cable. 100.0 Mtr 154.0 15400.0 c 40mm dia steel short piece. 2.0 Each 202.0 404.0 d Steel rope wit cover. 100.0 Mtr 35.4 3540.0 e Well Cap. 1.0 Each 202.0 202.0 f 50mm size CI bracket. 1.0 Each 121.2 121.2 g 20mm dia rigid HDPE pipes. 100.0 Mtr 99.8 9980.0 h 8\\" Boring up to 30 mtr. 40.0 Mtr 890.3 35612.0 i 8\\" Boring work Above 30 mtr. 60.0 Mtr 890.3 53418.0 j 8'' ASTM pipe SCH-80 100.0 Mtr 2290.46 229046.0 k Delivery 1.0 Set 2000.0 2000.0 l Labour charges for lowering of summerssible pumpset with pipes and cables etc with testing and commissioning at site. 100.0 Mtr 125.0 12500.0 Total Rs. 2816224.5148262 Name of the work- Construction Of Godabarish Mishra Adarsh Prathamik Vidyalaya At UGHS Kongra, Jharigam Block, Chaklapadar(GP), Nabarangpur District (Phase-II) INTERNAL ELECTRICAL WORK FOR SCHOOL BUILDING Sl. No. DESCRIPTION OF ITEMS QUANTITY UNIT RATE AMOUNT Rs. INTERNAL WIRING |
| 166 | Recessed wiring to light point / first light of group control/ call bell point/ exhaust fan point /wall fan point with 1.5 sq.mm FRLSH PVC insulated single core multistrand copper conductor of ISI marked in 20 mm dia non-metalic PVC conduit with 6 Amp, 250 V clip in type switch ISI marked and ceiling rose ISI marked mounted on G.I modular box with face plate & cover of suitable size , with 1.5 sq.mm FRLSH PVC insulated single core multistrand copper conductor as earth wire including all accesories and connection as per direction of Engineer in Charge. Group C 150.0 Nos. 1269.0 190350.0 |
| 167 | Recessed wiring to secondary light point looped from primary light point with 1.5sqmm FRLSH PVC insulated single core multistrand copper conductor of ISI marked with 20mm dia non-metallic PVC conduit with 1.5sqmm FRLSH PVC insulated single core multistrand copper conductor for running earth including 3 plate ISI marked Ceiling rose with all accessories & connection as per direction of Engineer-in-charge.Average Length: 3 mtr |
| 168 | Recessed wiring to ceiling fan point with 1.5sqmm FRLSH PVC insulated single core multistrand copper conductor of ISI marked with 20mm dia non-metallic PVC conduit with 6Amp 250V Modular Switch,Stepped type Moudular Regulator, Base & Cover with 1.5sqmm FRLSH PVC insulated single core multistrand copper conductor for running earth including all accessories & connection as per direction of Engineer in charge. Group c |
| 169 | Recessed wiring to Twin control light point with 1.5 sq.mm FRLSH PVC insulated single core multistrand copper conductor of ISI marked in 20 mm dia non-metalic PVC conduit with 6Amp, 250 V clip in type 2way switch ISI marked and ceiling rose ISI marked mounted on G.I modular box with face plate & cover of suitable size , with 1.5 sq.mm FRLSH PVC insulated single core multistrand copper conductor as earth wire including all accesories and connection as per direction of Engineer-in-charge.Group C |
| 170 | Recessed wiring for 5 / 6 amp socket outlet with 6Amp, 250 V clip in type modular switch ISI marked mounted on G.I moular box with face plate & cover of suitable size including all accesories and connection on same switch board as per direction of Engineer-in-charge. |
| 171 | Recessed wiring for 5 / 6 amp socket outlet with 2 x 1.5 sq.mm FRLSH PVC insulated single core multistrand copper conductor of ISI marked in 20 mm dia non-metalic PVC conduit with 6Amp, 250 V clip in type switch ISI marked mounted on G.I moular box with face plate & cover of suitable size , with 1.5 sq.mm FRLSH PVC insulated single core multistrand copper conductor as earth wire including all accesories and connection on separate board as per direction of Engineer-in-charge.Group C |
| 172 | Recessed wiring for 2 x 6 amp socket outlet controlled by 2 nos 6Amp, 250 V clip in type switch ISI marked mounted on single G.I moular box with face plate & cover of suitable size including all accesories and connection on separate board as per direction of Engineer-in-charge. |
| 173 | Recessed wiring for 6 pin 16 amp socket outlet with 16Amp, 250 V clip in type switch ISI marked mounted on G.I moular box with face plate & cover of suitable size including all accesories and connection as per direction of Engineer-in-charge. |
| 174 | Recessed wiring for A.C/ Power socket outlet with industrial type socket outlet, plug top and metal chained cover in sheet steel enclosure ,20A/32A SP MCB including all accesories and connection as per direction of Engineer-in-charge. |
| 175 | Recessed wiring to exhaust fan/Wall Fan point with 1.5sqmm FRLSH PVC insulated single core multistrand copper conductor of ISI marked with 20mm dia non-metallic PVC conduit with 6Amp 250V Modular Switch, Base & Cover with 1.5sqmm FRLSH PVC insulated single core multistrand copper conductor for running earth including all accessories & connection as per direction of Engineer in charge.Group C |
| 176 | Call bell point |
| 177 | Recessed wiring for 3 x 6 amp socket outlet controlled by 2 nos 6Amp, 250 V clip in type switch ISI marked mounted on single G.I moular box with face plate & cover of suitable size including all accesories and connection on separate board as per direction of Engineer-in-charge. SUBMAIN |
| 178 | Recessed wiring to submain in 4 x 10 sq.mm FRLSH PVC insulated single core multistrand copper conductor of ISI marked confirming to IS-694/1990 in 32 mm dia non-metalic heavy duty PVC conduit 1.6 mm thick along with 2 x 4 sq.mm FRLSH PVC insulated single core multistrand copper conductor as earth wire as equired. |
| 179 | Recessed wiring to submain in 4 x 6 sq.mm FRLSH PVC insulated single core multistrand copper conductor of ISI marked confirming to IS-694/1990 in 32 mm dia non-metalic heavy duty PVC conduit 1.6 mm thick along with 2 x 2.5 sq.mm FRLSH PVC insulated single core multistrand copper conductor as earth wire as equired. |
| 180 | Recessed wiring to submain in 2 x 6 sq.mm FRLSH PVC insulated single core multistrand copper conductor of ISI marked confirming to IS-694/1990 in 25 mm dia non-metalic heavy duty PVC conduit 1.6 mm thick along with 1 x 2.5 sq.mm FRLSH PVC insulated single core multistrand copper conductor as earth wire as equired. |
| 181 | Recessed wiring to submain in 2 x 4 sq.mm FRLSH PVC insulated single core multistrand copper conductor of ISI marked confirming to IS-694/1990 in 20 mm dia non-metalic heavy duty PVC conduit 1.6 mm thick along with 1 x 1.5 sq.mm FRLSH PVC insulated single core multistrand copper conductor as earth wire as equired. |
| 182 | Recessed wiring to submain in 2 x 2.5 sq.mm FRLSH PVC insulated single core multistrand copper conductor of ISI marked confirming to IS-694/1990 in 20 mm dia non-metalic heavy duty PVC conduit 1.6 mm thick along with 1 x 1.5 sq.mm FRLSH PVC insulated single core multistrand copper conductor as earth wire as equired. |
| 183 | Recessed wiring to submain in 2 x 1.5 sq.mm FRLSH PVC insulated single core multistrand copper conductor of ISI marked confirming to IS-694/1990 in 20 mm dia non-metalic heavy duty PVC conduit 1.6 mm thick along with 1 x 1.5 sq.mm FRLSH PVC insulated single core multistrand copper conductor as earth wire as equired. |
| 184 | DB Supply and fixing of following way three pole and neutral, sheet steel, MCB distribution, 415 V on surface / recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, hinged front acrylic cover for the MCB knobs detachable gland plate, interconnections, phosphatized and powder painted including earthing etc. as required wih necessary MCB , RCCB / ISOLATORS as required.Note for MCB- There should be colour indication for tripping On ,Off & Trip/There should be mid trip position for toggles for electrical fault conditions. a) Supply, fixing, erecting, connecting and commissioning of indoor type dust and vermin proof, sheet steel clad ready made, double door horizontal type powder coated wall mounted 4 way TPN Distribution Boards For PDB suitable for 440 V, three phase, 4 wire 50 Hz AC Supply complete with bottom detachable plate for interconnections etc as below.Incommer 1 No-63A FP MCB (10KA) Outgoings-10/20A SP MCB 10KA-12Nos. 3.0 Nos. 14143.0 42429.0 Supply, fixing, erecting, connecting and commissioning of indoor type dust and vermin proof, sheet steel clad ready made, double door horizontal type powder coated wall mounted 4 way TPN Distribution Boards For LDB suitable for 440 V, three phase, 4 wire 50 Hz AC Supply complete with bottom detachable plate for interconnections etc as below.Incommer 1 No-40A FP MCB (10KA) Outgoings-10A SP MCB 10KA-12Nos. 3.0 Nos. 14143.0 42429.0 c) Supply, fixing, erecting, connecting and commissioning of indoor type dust and vermin proof, sheet steel clad ready made, double door horizontal type powder coated wall mounted 4 way TPN Distribution Boards For UPS DB suitable for 440 V, three phase, 4 wire 50 Hz AC Supply complete with bottom detachable plate for interconnections etc as below.Incommer 1 No-40A FP MCB (10KA) Outgoings-10A SP MCB 10KA-12Nos. 3.0 Nos. 14143.0 42429.0 CABLE |
| 185 | Supply & Laying of one number of PVC insulated and PVC seathed / XLPE power cable of 1.1 KV grade of 3.5core 150 sq.mm direct in ground including excavation , sand cushining protective covering and refilling the trench etc. as required. |
| 186 | Supply & Laying of one number of PVC insulated and PVC seathed / XLPE power cable of 1.1 KV grade of 3.5core 95 sq.mm direct in ground including excavation , sand cushining protective covering and refilling the trench etc. as required. |
| 187 | Supply & Laying of one number of PVC insulated and PVC seathed / XLPE power cable of 1.1 KV grade of 4 core 16 sq.mm Aluminium on surface as required. END TERMINATION Supplying and making end termination with brass compression gland and aluminum lugs for following size of PVC insulated and PVC sheathed / XLPE aluminum cable of 1.1 KV as required. |
| 188 | 3.5C x 150 sq.mm |
| 189 | 3.5C x 95 sq.mm |
| 190 | 4C x 16 sq.mm PANEL Supply, installation,testing & commissioning of floor mounting front operated front access extensible type cubicle panel totally enclosed, dust and vermin proof with IP-42 /55 protection with hinged and lockabale doors.CRCA sheets including interconnections,tinned copper crimping lugs, bonding to earth and painting suitable for use at 415 V, 3phase 4 wire 50 Hz system, and to withstand a fault level of 35 KA symmetrical for 1 sec at 415 V complete as per specifications, as required and as below : All switchboards shall have provision for entry of cables from the bottom as required. All live accessible parts shall be shrouded and all equipment shall be finger touch proof. The bus bars shall be insulated with heat shrinkable sleeves.SMC/DMC shrouds and busbar supports shall be used with Indication lamp, C.T , Digital Voltmeter, Digital Ammeter and control fuse etc. complete. |
| 191 | MAIN PANEL with 150A 4P MCCB 36KA -1 No as incomer, 63A 4P MCB 10KA 4Nos,100A 4P Change over Switch 1Nos, 40A 4P MCB 10KA.-9Nos, 32A DP MCB 10KA-3Nos with E.C Busbars with 4nos 65KA VSD along with 4nos 32A SP MCB. EARTHING |
| 192 | Earthing with copper earth plate 600 mm x 600mm x 3.15 mm thick ISI marked including accessories and providing masonary with cover plate having loccking arrangement and watering pipe etc with charcoal and salt as required. |
| 193 | Supplying and laying 25 mm x 6 mm CU earth strip ISI marked at 0.5 meter below ground level as strip earth electrode including soldering etc. as required. |
| 194 | Supplying and laying 25 mm x 6 mm CU earth strip ISI marked on surface or in recess for connection etc as required. |
| 195 | Providing and fixing 8 SWG CU wire on surface or in recess for loop earthing as required. FIXTURE Supply, Installation, Testing and Commissioning of pre-wired fluorescent fiiting / compact fluorescent fitting /LED fitting of all sizes complete with all accessories and lamp etc. directly on ceiling /wall or recessed in false ceiling , including connection with 1.5 sq.mm FR PVC insulated single core multistrand copper conductor and earthing as required. |
| 196 | Ceiling mounted indoor type batten type LED Luminaire with LED Lamp |
| 197 | Ceiling/ Wall mounted type BULK HEAD Luminaire |
| 198 | Supply, Installation, testing and commissioning of 10W Mirror Light |
| 199 | Supply, Installation, Testing and Commissioning of ceiling fan 1200mm sweep, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq.mm FR PVC insulated single core multiatrand copper conductor etc. as required.BLDC 5 Star |
| 200 | Supply, Installation, testing and commissioning of exhaust fan of 250 mm PLASTIC Exhaust Fan (Vntilation Fan) complete, connection, etc as required.250MM CRISP AIR EXH FAN. |
| 201 | Supply & fixing of 18W LED Down Light (S/R) with all accessories. |
| 202 | Supply & fixing of LED 36w 2'x2' Surface/Recessed Mounted Light as required . |
| 203 | Supply & fixing of 6W LED Down Light (S/R) with all accessories. |
| 204 | Supply, Installation, testing and commissioning of wall fan of 400 mm sweep as required.Model-400mm STRIKER HI SPEED. PERFORATED CABLE TRAY Supply and installation of Pregalvanised Perforated type cable trays without cover. The rate shall include bends, Tees, all supporting brackets, anchor fasteners, screws, bolts, nuts etc., including painting of cable trays. Thickness of sheet steel shall be 2 mm. Support sizes similar to ladder type trays. |
| 205 | Size of Cable Tray :300 mm x 50 mm |
| 206 | Size of Cable Tray :150 mm x 50 mm ------------------- TOTAL INTERNAL ELECTRICAL WORK= 2696439.0 BOQ ABSTRACT Construction Of Godabarish Mishra Adarsh Prathamik Vidyalaya At Govt. UGHS Ichhapur, Jharigam Block, Ichhapur (GP) , Nabarangpur District (Phase-II) Sl.No Description Amount |
| 207 | All Civil Work (Civil Work+Solar+Fire+Landscaping) |
| 208 | P.H. & Sanitary Work |
| 209 | Electrical Work TOTAL 48862404.0 Construction Of Godabarish Mishra Adarsh Prathamik Vidyalaya At Govt. UGHS Ichhapur, Jharigam Block, Ichhapur (GP) , Nabarangpur District (Phase-II) BILL OF QUANTITIES (CIVIL WORK) Sl.No. Description of items GROUND FLOOR TERRACE C.WALL & FENCING APP ROAD FENCING Rain Waer Harvesing Paver-Road Quantity Unit Rate (Rs,) Amount (Rs.) DISMANTLING WORKS Removing white or colour wash by scrapping and sand papering and preparing the surface smooth including necessary repairs to scratches etc.complete 0.0 0.0 (a) Ground Floor 0.0 Sqm 10.5 0.0 (b) First Floor 0.0 Sqm 10.5 0.0 Dismantling brick or stone masonry in lime or cement mortar above 3m. height including stacking the useful materials for reuse and removing the debris within 50m. Lead 0.0 0.0 (a) Ground Floor 0.0 Cum 1743.4812720848058 0.0 (b) First Floor 0.0 Cum 1830.7 0.0 Removing old lime or cement plaster from walls including raking out joints 12 mm deep and removing the debris within 50m lead 0.0 0.0 (a) Ground Floor 0.0 Sqm 58.9537 0.0 (b) First Floor 0.0 Sqm 61.9 0.0 (c) Second Floor 0.0 Sqm 65.0 0.0 Dismantling and removing old tiled flooring including removing the base coarse and stacking the useful materials for reuse and removing the debris within 50m lead 0.0 0.0 (a) Ground Floor 0.0 Sqm 147.3691 0.0 (b) First Floor 0.0 Sqm 154.7 0.0 Dismantling and removing old tiled cladding from walls including racking out joints 12mm deep stacking the useful materials for reuse and removing the debris within 50m lead 0.0 0.0 (a) Ground Floor 0.0 Sqm 76.63879999999999 0.0 (b) First Floor 0.0 Sqm 80.5 0.0 Dismantling and removing doors, windows and ventilators including removal of frame, hinges, fastening and stacking the same for reuse and removing the debris within 50m lead 0.0 0.0 (a) Ground Floor 0.0 Sqm 465.1353 0.0 (b) First Floor 0.0 Sqm 488.4 0.0 Dismantling and removing cement concrete including stacking the useful materials for reuse and removing the debris within 50m lead 0.0 0.0 (a) Ground Floor 0.0 Cum 877.1648 0.0 (b) First Floor 0.0 Cum 921.0 0.0 Dismantling and removing R.C.C. columns beams slab staircase landing, lintels including stacking the useful materials for reuse and removing the debris within 50m lead. 0.0 0.0 (a) Ground Floor 0.0 Cum 1731.81 0.0 (b) First Floor 0.0 Cum 1818.4 0.0 Dismantling G.C.I. or A.C. sheet roofing after carefully removing the bolts and nuts including stacking of the materials for reuse and removing the debris within 50m lead 0.0 0.0 (a) Terace Floor 0.0 Sqm 106.28 0.0 Dismantling wrought and framed timber in roof frame work of floors after careful removal of nail, bolts etc. and stacking of the materials for reuse and removing the debris within 50m lead 0.0 0.0 (a) Terace Floor 0.0 cum 1478.9531 0.0 Dismantling and removing 2.5 cm thick grading concrete from roof slab cleaning the surface lowering and removing the debris within 50m lead 0.0 0.0 (a) Ground Floor 0.0 Sqm 132.6332 0.0 (b) First Floor 0.0 Sqm 139.3 0.0 (a) Terace Floor 0.0 Sqm 146.2 0.0 Disposal of moorum/building rubbish/ malba/ similar unserviceable, dismantled or waste material by mechanical transport including loading, transporting, unloading to approved municipal dumping ground for lead upto 10 km for all lifts, complete as per directions of Engineer-in-charge. 0.0 0.0 (a) Ground Floor 0.0 Cum 330.8 0.0 (b) First Floor 0.0 Cum 330.8 0.0 (c) Second Floor 0.0 Cum 330.8 0.0 0.0 0.0 0.0 0.0 0.0 0.0 Cutting of trees, including cutting of trunks, branches and removal of stumps, roots, stacking of serviceable material with all lifts and up to a lead of 1000 metres and earth filling in the depression/pit. 0.0 0.0 Girth from 300mm to 600mm 0.0 Each 385.0 0.0 A CIVIL WORK SUB-STRUCTURE CIVIL WORK 0.0 Clearing and grubbing roads and land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300 mm, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, up to a lead of 1000 metres including removal and disposal of top organic soil not exceeding 150 mm in thickness. 10.58 10.58 Sqm 8.63 91.3054 EARTH WORK |
| 210 | Excavation, loading, unloading and carriage by mechanical means of all kinds of soil, including stoney earth, gravel and moorum etc interspread with boulders upto 1/2 cum size with all lifts and delifts including trimming of slopes and bed to design section and depositing the the excavated materials away from work site as per the specification and as directed by the Engineer- in-charge within an initial lead of 1km from the place of excavation complete. 2304.18 68.04 32.24 40.0 2444.4599999999996 Cum 146.7 358602.2819999999 9981.468 0.0 338023.20599999995 Earth work in excavation in foundation trenches, column foundation, pit, etc in all kind of soil including moorum stony earth and earth mixed with boulders except sheet rock and boulders not requiring blasting including dressing of sides and levelling the bed up to the required depth and depositing the excavated materials away from the work site with initial lead of 50 mtr and all lifts, including shoring, shuttering & dewatering (if required) with cost of labour, labour cess, hire & running charges of all machineries, sundries & T&P required for the work complete as directed by the Engineer in charge. 0.0 0.0 0.0 0.0 0.0 Upto 1.5mtr Depth 0.0 Cum 282.9 0.0 0.0 0.0 0.0 From 1.5mtr Depth to 3.0mtr Depth 0.0 Cum 305.36 0.0 0.0 0.0 0.0 |
| 211 | Filling the Plinth with excavated materials (excluding rock), in layers not exceeding 0.225 m in depth including cost of watering, ramming, dressing and levelling the top to proper level & gradient, cost of labour, conveyance, loading, unloading, T&P, etc, all complete as per the direction of Engineer-in-Charge. 1536.12 45.36 1581.4799999999998 Cum 157.2 248608.65599999996 7130.592 0.0 241478.06399999995 |
| 212 | Filling the Foundation, Sides of Foundation, etc. in mechanical means with excavated materials (excluding rock), in layers not exceeding 0.225 m in depth including cost of watering, ramming, dressing and levelling the top to proper level & gradient, cost of machinary, conveyance, loading, unloading, T&P, etc, all complete as per the direction of Engineer-in-Charge. 0.0 0.0 Cum 146.7 0.0 0.0 0.0 0.0 Disposal of surplus/ excavated materials by mechanical means within 5km. Lead away from the site including cost of all labour , T&P complete as per the direction of the Engineer-in-charge. 0.0 0.0 0.0 0.0 0.0 (a)Ground Floor 0.0 Cum 278.8 0.0 0.0 0.0 0.0 |
| 213 | Supplying, diluting and preparing chemical emulsion like Imidacloprid 30.5 % SC or other chemicals approved by Central Insecticides Board or as directed by the manufacturer and spraying the mixture uniformly by sprayer as Pre/Post-Constructional Anti-termite Treatment confirming to IS 6313 (Part-II) including the cost of all materials, cost of all labour, conveyance, loading, unloading, T&P, etc. all complete as per the direction of Engineer-in-Charge. 1818.06 1818.06 sqm 104.5 189987.27 0.0 0.0 189987.27 |
| 214 | Supplying and Filling with Sand in Foundation and Plinth in layers not exceeding 20 cm in depth, well watered and compact , top surface dressed and levelled to proper level and gradient including cost of all materials , conveyance, royalties, loading, unloading, cost of all labour, T&P, etc.All compelete as per the dirrection of Engineer-in-charge. 1060.1345000000001 8.43 3.18 24.0 1095.7445000000002 Cum 712.4 780608.3818000002 6005.531999999999 0.0 755239.8178000001 |
| 215 | Providing and lying Plain Cement Concrete of proportion (1:3:6) in foundation & floor using 40 mm & down grade black hard crusher broken granite stone metal, washed and screened sharp sand of approved quality from approved quarry including hoisting, lowering, laying the concrete, ramming, watering and curing etc. complete to required thickness including cost of all materials, conveyance, loading, unloading, royalties, cost of labours, T&P, hire & running charges of concrete mixer, etc. all complete as per the direction of the Engineer -in -charge. 319.18 8.43 327.61 Cum 6028.0 1974833.08 50816.04 0.0 1924017.04 Depth 1.5 to 4.5mtr lvl 0.0 Cum 6366.6 0.0 0.0 0.0 0.0 |
| 216 | Providing and lying Plain Cement Concrete of proportion (1:4:8) in foundation & floor using 40 mm & down grade black hard crusher broken granite stone metal, washed and screened sharp sand of approved quality from approved quarry including hoisting, lowering, laying the concrete, ramming, watering and curing etc. complete to required thickness including cost of all materials, conveyance, loading, unloading, royalties, taxes, cost of labours, T&P, hire & running charges of concrete mixer, etc. all complete as per the direction of the Engineer -in -charge. Ground Floor 24.0 24.0 Cum 5643.8 135451.2 0.0 0.0 0.0 Depth 1.5 to 4.5mtr lvl 1.28 1.28 Cum 5982.4 7657.472 0.0 0.0 0.0 |
| 217 | Providing and laying in position of plain cement concrete 1:2:4 (1 Cement :2 Sand :4 Coarse Agreegate) in floors using 12mm size hard broken crusher broken granite stone metal, washed and screened sharp sand of approved quality from approved quarry including hoisting, lowering, laying the concrete, ramming, watering and curing etc. complete to required thickness including cost of all materials, conveyance, loading, unloading, royalties, cost of labours, T&P, hire & running charges of concrete mixer, etc. all complete as per the direction of the Engineer -in -charge. Ground Floor 13.089374999999999 13.089374999999999 Cum 7641.3 100019.84118749999 0.0 0.0 100019.84118749999 RCC WORK 0.0 0.0 0.0 0.0 Providing, lifting, hoisting and laying in position machine batched , machine mixed and machine vibrated design mix cement concrete of M-25(minimum cement content not less than 403 Kg/Cum) grade in reinforced cement concrete structural elements using black hard crusher broken granite chips of approved quality from approved quarry including mixing and compacting to proper shape and size, level and plumbs and finishing the exposed surfaces smooth including the cost of all materials, cost of labour, conveyance,loading, unloading, royalties, watering and curing for the required period, T&P , hire & running charges of concrete mixer and vibrator, cost of Admixtures in recommended proportions ( as per IS 9103 ) to accelerate, retard setting of concrete, improve workability without impairing strength and durability etc. complete as per the direction of the Engineer-in-charge but excluding the cost of steel reinforcement & centring shuttering. 0.0 0.0 0.0 0.0 0.0 Ground Floor 0.0 Cum 6470.7 0.0 0.0 0.0 0.0 First Floor 0.0 Cum 6595.5 0.0 0.0 0.0 0.0 |
| 218 | Providing, lifting, hoisting and laying in position machine batched , machine mixed and machine vibrated design mix cement concrete of M-25 Including the cost of Centering and Shuttering (minimum cement content not less than 403 Kg/Cum) grade in reinforced cement concrete structural elements using black hard crusher broken granite chips of approved quality from approved quarry including mixing and compacting to proper shape and size, level and plumbs and finishing the exposed surfaces smooth including the cost of all materials, cost of labour, conveyance,loading, unloading, royalties, watering and curing for the required period, T&P , hire & running charges of concrete mixer and vibrator, cost of Admixtures in recommended proportions ( as per IS 9103 ) to accelerate, retard setting of concrete, improve workability without impairing strength and durability etc. complete as per the direction of the Engineer-in-charge but excluding the cost of steel reinforcement. (A)R.C.C. foundation and footing bases of columns mass concrete pre-cast slab etc. 0.0 0.0 0.0 0.0 (a)Ground Floor 497.66 9.0 506.66 Cum 6845.4 3468290.364 61608.6 0.0 3406681.764 (B)R.C.C. Column uto plinth 0.0 0.0 0.0 0.0 Ground Floor 28.03 1.91 29.94 Cum 16228.2 485872.308 30995.862 0.0 454876.44600000005 |
| 219 | Providing & fixing TOR Fe-500 HYSD Reinforcement bars of required diameter and approved quality for Reinforced Cement Concrete work including straightening, cutting, bending, binding, welding(if approved) , joining (if necessary), tying the grills, hoisting, lowering and placing in position as per the approved design & drawings (BBS) with provision of standard fan hooks including the cost of all materials, cost of all labour, conveyance, loading, unloading, cost of binding wires of 18 to 20 gauge, T&P, etc, all complete as per the direction of Engineer-in-Charge.Note: (Linear measurements will be taken & quantity will be calculated on standard weight. Lap length of bars & Weight of binding wire will not be considered for measurement and payment). 0.0 0.0 0.0 GROUND FLOOR SUB STRUCTURE 448.58 10.64 459.21999999999997 Qntl 9275.4 4259449.187999999 98690.25600000001 0.0 4160758.9319999996 0.0 0.0 0.0 MASSONARY WORKS 0.0 0.0 0.0 0.0 |
| 220 | Providing and laying Brick Masonry work in Foundation & Plinth using Fly ash bricks of 25 Cm. x 12 Cm. x 8 Cm. size having crushing strength not less than 75 Kg./Cm2 with dimensional tolerance + 2 % confirming to IS 12894 and IS 2212 in cement mortar (1:6) affter immersing the bricks for minimum 6 hours in water before use, with all necessary projections, splays cutting, circular moulding, corbelling, etc. as per the drawings including the cost of all materials, cost of all labour, conveyance, royalties, loading, unloading, scaffolding, staging, watering and curing, sundries, T&P, etc. complete as per the direction of the Engineer-in-charge. (a)Ground Floor 104.18 13.27 13.22 130.67000000000002 Cum 5597.1 731373.0570000001 74273.517 0.0 583105.878 0.0 0.0 0.0 |
| 221 | Supplying and fixing of 80mm thick cement concrete interlocking paver block of M-40 grade of approved make, design, colour and size made by Block making machine with proper compaction laid in required pattern etc. complete in all respect conforming to IRC SP - 63:2018. |
| 222 | Supplying and fixing of Pre cast kerb stone of size 300mm x 300mm x 150mm of M-30 grade of approved make, design, colour and size made by Block making machine with proper compaction fixed in required pattern etc. complete in all respect conforming to IS 5758:1984. |
| 223 | Painting two coats of synthetic enamel paint on road work over Plaster or RCC Works like (kerb wall,bridge rcc barrier) as per approved shade of approved quality , sand papering, polishing the surface including cost, conveyance,labour, T&P, scaffolding etc. as required for the work complete as per direction of Engineer-in-charge. (The paints are to be approved before procurement and use) KERB PAINTING 39.6 39.6 Sqm 84.5 3346.2000000000003 0.0 0.0 0.0 0.0 0.0 0.0 TOTAL 12889327.2453875 0.0 0.0 0.0 0.0 0.0 0.0 SUPER-STRUCTURE 0.0 0.0 0.0 RCC WORK 0.0 0.0 0.0 |
| 224 | Providing, lifting, hoisting and laying in position machine batched , machine mixed and machine vibrated design mix cement concrete of M-25 Including the cost of Centering and Shuttering (minimum cement content not less than 403 Kg/Cum) grade in reinforced cement concrete structural elements using black hard crusher broken granite chips of approved quality from approved quarry including mixing and compacting to proper shape and size, level and plumbs and finishing the exposed surfaces smooth including the cost of all materials, cost of labour, conveyance,loading, unloading, royalties, watering and curing for the required period, T&P , hire & running charges of concrete mixer and vibrator, cost of Admixtures in recommended proportions ( as per IS 9103 ) to accelerate, retard setting of concrete, improve workability without impairing strength and durability etc. complete as per the direction of the Engineer-in-charge but excluding the cost of steel reinforcement. a R.C.C. Plinth Beam 0.0 0.0 0.0 0.0 (a)Ground Floor 90.23 6.68 1.0 97.91 Cum 7719.8 755845.618 51568.263999999996 0.0 696557.554 b (B)R.C.C. Column & Roof Beam 0.0 0.0 0.0 0.0 Ground Floor 170.01 1.75 171.76 Cum 16228.2 2787355.6319999998 28399.350000000002 0.0 2758956.282 Terrace 12.91 12.91 Cum 18304.5 236311.095 0.0 236311.095 0.0 Second Floor 0.0 Cum 20789.9 0.0 0.0 0.0 0.0 Third Floor 0.0 Cum 23765.1 0.0 0.0 0.0 0.0 Fourth Floor 0.0 Cum 27327.2 0.0 0.0 0.0 0.0 Fifth Floor 0.0 Cum 31592.1 0.0 0.0 0.0 0.0 SiXth Floor 0.0 Cum 36699.2 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 c (C) R.C.C. Slab & RCC Chajja 0.0 0.0 0.0 0.0 Ground Floor 269.96999999999997 0.44 270.40999999999997 Cum 12624.2 3413709.922 5554.648 0.0 3408155.2739999997 Terrace 19.290000000000003 19.290000000000003 Cum 13979.8 269670.342 0.0 269670.342 0.0 Second Floor 0.0 Cum 15600.2 0.0 0.0 0.0 0.0 Third Floor 0.0 Cum 17537.5 0.0 0.0 0.0 0.0 Fourth Floor 0.0 Cum 19854.1 0.0 0.0 0.0 0.0 Fifth Floor 0.0 Cum 22624.4 0.0 0.0 0.0 0.0 SiXth Floor 0.0 Cum 25937.8 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 d (D)R.C.C. Staircase 0.0 0.0 0.0 0.0 Ground Floor 9.78 9.78 Cum 16090.4 157364.112 0.0 0.0 157364.112 Terrace 0.0 Cum 18139.2 0.0 0.0 0.0 0.0 Second Floor 0.0 Cum 20591.5 0.0 0.0 0.0 0.0 Third Floor 0.0 Cum 23527.2 0.0 0.0 0.0 0.0 Fourth Floor 0.0 Cum 27041.6 0.0 0.0 0.0 0.0 Fifth Floor 0.0 Cum 31249.4 0.0 0.0 0.0 0.0 SiXth Floor 0.0 Cum 36287.9 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 e (E)R.C.C. lintel 0.0 0.0 0.0 0.0 Ground Floor 34.64 34.64 Cum 14559.2 504330.688 0.0 0.0 504330.688 Terrace 0.58 0.58 Cum 16301.7 9454.985999999999 0.0 9454.985999999999 0.0 Second Floor 0.0 Cum 18386.6 0.0 0.0 0.0 0.0 Third Floor 0.0 Cum 20881.2 0.0 0.0 0.0 0.0 Fourth Floor 0.0 Cum 23866.5 0.0 0.0 0.0 0.0 Fifth Floor 0.0 Cum 27439.4 0.0 0.0 0.0 0.0 SiXth Floor 0.0 Cum 31715.9 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 f (F)R.C.C. Fins 0.0 0.0 0.0 0.0 Ground Floor 1.66 1.66 Cum 11908.4 19767.944 0.0 0.0 19767.944 First Floor 0.0 Cum 13120.8 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 R.C.C. Grade Slab 0.0 0.0 0.0 0.0 0.0 Ground Floor 0.0 Cum 6845.4 0.0 0.0 0.0 0.0 Double under reamed pile foundation with R.C.C. M25 using 12mm size black hard granite (crusher broken)stone chips including cost of boreholes but excluding cost of M.S. rod/Tor steel and labour chrages for cutting, bending and binding of steel. 0.0 0.0 0.0 0.0 0.0 450mm Dia & 6.00Mtr Long Per One Pile 0.0 Nos 16301.14 0.0 0.0 0.0 0.0 For Each Addl. Depth of 0.50Mtr Beyond Initial Depth of 6.0Mtr add Extra to Rate 0.0 Nos 776.5 0.0 0.0 0.0 0.0 |
| 225 | Providing and lying plain cement concrete of proportion (1:6:12) in false column with 40 mm. Size black hard crusher broken granite stone metal and screened and washed sharp sand for mortar of approved quality from approved quarry, washed and cleaned including hoisting, lowering, laying concrete, ramming, watering and curing etc. complete to required levels laid in layers not exceeding 15 cm thick in each layer including cost, conveyance, loading, unloading, royalties and taxes all materials and cost all labours, sundries, T & P required for the work including shoring, shuttering and dewatering if required including hire & running charges of water pump complete as per the instruction of the Engineer-in-Charge. |
| 226 | Providing & fixing TOR Fe-500 HYSD Reinforcement bars of required diameter and approved quality for Reinforced Cement Concrete work including straightening, cutting, bending, binding, welding(if approved) , joining (if necessary), tying the grills, hoisting, lowering and placing in position as per the approved design & drawings (BBS) with provision of standard fan hooks including the cost of all materials, cost of all labour, conveyance, loading, unloading, cost of binding wires of 18 to 20 gauge, T&P, etc, all complete as per the direction of Engineer-in-Charge.Note: (Linear measurements will be taken & quantity will be calculated on standard weight. Lap length of bars & Weight of binding wire will not be considered for measurement and payment). Ground Floor 755.81 12.9 1.1 769.81 Qntl 9275.4 7140295.674 119652.66 0.0 7010440.073999999 Terrace 56.63 56.63 Qntl 9309.47 527195.2861 0.0 527195.2861 0.0 Second Floor 0.0 Qntl 9345.27 0.0 0.0 0.0 0.0 Third Floor 0.0 Qntl 9382.9 0.0 0.0 0.0 0.0 Fourth Floor 0.0 Qntl 9422.4 0.0 0.0 0.0 0.0 Fifth Floor 0.0 Qntl 9463.8 0.0 0.0 0.0 0.0 SiXth Floor 0.0 Qntl 9507.3 0.0 0.0 0.0 0.0 0.0 0.0 0.0 MASSONARY WORKS 0.0 0.0 0.0 |
| 227 | Providing and laying Brick masonry work in Superstructure using Fly ash bricks of 25 Cm. x 12 Cm. x 8 Cm. size having crushing strength not less than 75 Kg./Cm2 with dimensional tolerance + 2 % confirming to IS 12894 and IS 2212 in cement mortar (1:4) for Half Brick Masonry Wall with provisions for 2 nos 6mm dia MS bar at each 4th layer after immersing the bricks for minimum 6 hours in water before use, with all necessary projections, splays cutting, circular moulding, corbelling, etc. as per the drawings including the cost of all materials, cost of all labour, conveyance, royalties, loading, unloading, scaffolding, staging, watering and curing, sundries, T&P, etc. complete as per the direction of the Engineer-in-charge. ( Excluding Cost Of Steel Reinforcement ). Ground Floor 20.37 20.37 Cum 5848.2 119127.834 0.0 0.0 119127.834 Terrace 0.0 Cum 6234.1 0.0 0.0 0.0 0.0 Second Floor 0.0 Cum 6678.0 0.0 0.0 0.0 0.0 Third Floor 0.0 Cum 7188.5 0.0 0.0 0.0 0.0 Fourth Floor 0.0 Cum 7775.5 0.0 0.0 0.0 0.0 Fifth Floor 0.0 Cum 8450.6 0.0 0.0 0.0 0.0 SiXth Floor 0.0 Cum 9226.9 0.0 0.0 0.0 0.0 |
| 228 | Providing and laying of Full Brick Masonry work in Superstructure using Fly ash bricks of 25 Cm. x 12 Cm. x 8 Cm. size having crushing strength not less than 75 Kg./Cm2 with dimensional tolerance + 2 % confirming to IS 12894 and IS 2212 in cement mortar (1:6) affter immersing the bricks for minimum 6 hours in water before use, with all necessary projections, splays cutting, circular moulding, corbelling, etc. as per the drawings including the cost of all materials, cost of all labour, conveyance, royalties, loading, unloading, scaffolding, staging, watering and curing, sundries, T&P, etc. complete as per the direction of the Engineer-in-charge. Ground Floor 452.95 20.79 473.74 Cum 5630.4 2667345.696 117056.01599999999 0.0 2550289.6799999997 Terrace 129.38 129.38 Cum 6016.4 778401.8319999999 0.0 778401.8319999999 0.0 Second Floor 0.0 Cum 6460.3 0.0 0.0 0.0 0.0 Third Floor 0.0 Cum 6970.7 0.0 0.0 0.0 0.0 Fourth Floor 0.0 Cum 7557.8 0.0 0.0 0.0 0.0 Fifth Floor 0.0 Cum 8232.9 0.0 0.0 0.0 0.0 SiXth Floor 0.0 Cum 9009.2 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 FINISHING WORK 0.0 0.0 0.0 0.0 |
| 229 | Providing 6 mm thick Cement Plaster in Cement Mortar of (1:4) to Ceilings of Roof Slabs, Stairs, Landings, Chajja, Shelves, Columns, Beams and Lofts etc. including roughening, scraping and cleaning and finishing the plastered surface smooth using wooden floats only to proper plumbs and level, making grooves, beads and drip coarse to give required ornamental finish as per drawings including cost of all materials, conveyance, loading and unloading and royalties, all labour, scaffolding, watering and curing , sundries, T&P etc. complete as per direction of the Engineer-in-charge Ground Floor 0.0 63.68 63.68 Sqm 215.8 13742.144 13742.144 0.0 0.0 Terrace 0.0 0.0 Sqm 221.4 0.0 0.0 0.0 0.0 Second Floor 0.0 Sqm 227.1 0.0 0.0 0.0 0.0 Third Floor 0.0 Sqm 233.0 0.0 0.0 0.0 0.0 Fourth Floor 0.0 239.1 0.0 0.0 0.0 0.0 Fifth Floor 0.0 245.4 0.0 0.0 0.0 0.0 SiXth Floor 0.0 251.9 0.0 0.0 0.0 0.0 Providing 12mm thick cement plaster in cement mortar (1:4) to the surface of half brick masonry wall including racking out joints, scraping and cleaning the surface and finishing the plaster surface smooth using wooden floats, bars, etc only to proper plumbs and level and making grooves, beads and drip coarse to give required ornamental finish as per drawings including cost of all materials, conveyance, loading and unloading, royalties, cost of all labour, scaffolding, staging, watering before plastering and curing, sundries and T&P, etc. complete as per direction of the Engineer-in-charge. 0.0 0.0 0.0 0.0 Ground Floor 0.0 Sqm 204.6 0.0 0.0 0.0 0.0 Terrace 0.0 Sqm 209.4 0.0 0.0 0.0 0.0 Second Floor 0.0 Sqm 214.3 0.0 0.0 0.0 0.0 Third Floor 0.0 Sqm 219.3 0.0 0.0 0.0 0.0 Fourth Floor 0.0 Sqm 224.5 0.0 0.0 0.0 0.0 Fifth Floor 0.0 Sqm 229.9 0.0 0.0 0.0 0.0 SiXth Floor 0.0 Sqm 235.4 0.0 0.0 0.0 0.0 |
| 230 | Providing 16mm thick cement plaster in cement mortar (1:6) to the surfaces of brick masonry wall including racking out joints, scraping and cleaning the surface and finishing the plaster surface smooth using wooden floats, bars, etc only to proper plumbs and level and making grooves, beads and drip coarse to give required ornamental finish as per drawings including cost of all materials, conveyance, loading and unloading, royalties, cost of labour, scaffolding, staging, watering before plastering and curing, sundries and T&P, etc. complete as per direction of the Engineer-in-charge.(inner side) Ground Floor 2382.24 239.25 2621.49 Sqm 278.1 729036.369 66535.425 0.0 662500.944 Terrace 750.14 750.14 Sqm 285.3 214014.942 0.0 214014.942 0.0 Second Floor 0.0 Sqm 292.6 0.0 0.0 0.0 0.0 Third Floor 0.0 Sqm 300.2 0.0 0.0 0.0 0.0 Fourth Floor 0.0 308.0 0.0 0.0 0.0 0.0 Fifth Floor 0.0 316.0 0.0 0.0 0.0 0.0 SiXth Floor 0.0 324.3 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 |
| 231 | Providing 12mm thick cement plaster in cement mortar (1:6) to the surface of brick masonry wall including racking out joints, scraping and cleaning the surface and finishing the plaster surface smooth using wooden floats, bars, etc only to proper plumbs and level and making grooves, beads and drip coarse to give required ornamental finish as per drawings including cost of all materials, conveyance, loading and unloading,royalties, cost of labour, scaffolding, staging, watering before plastering and curing, sundries and T&P, etc. complete as per direction of the Engineer-in-charge.(Outer side) Ground Floor 3108.05 3108.05 Sqm 192.3 597678.015 0.0 0.0 597678.015 Terrace 517.53 517.53 Sqm 200.3 103661.259 0.0 103661.259 0.0 Second Floor 0.0 Sqm 208.6 0.0 0.0 0.0 0.0 Third Floor 0.0 Sqm 217.4 0.0 0.0 0.0 0.0 Fourth Floor 0.0 Sqm 226.5 0.0 0.0 0.0 0.0 Fifth Floor 0.0 Sqm 236.2 0.0 0.0 0.0 0.0 SiXth Floor 0.0 Sqm 246.3 0.0 0.0 0.0 0.0 Providing 12mm thick cement plaster in cement mortar (1:4) with neat cement punning including racking out joints, scraping and cleaning the surface and finishing the plaster surface smooth using wooden floats, bars, etc only to proper plumbs and level and making grooves, beads and drip coarse to give required ornamental finish as per drawings including cost of all materials, conveyance, loading and unloading, taxes, royalties, cost of all labour, scaffolding, staging, watering before plastering and curing, sundries and T&P, etc. complete as per direction of the Engineer-in-charge. 0.0 0.0 0.0 0.0 Ground Floor 20.24 20.24 Sqm 212.4 4298.976 0.0 0.0 0.0 Extra for plastering done on moulding, cornices or architraves including neat finish to lineand level: 0.0 0.0 0.0 0.0 0.0 Ground Floor 0.0 Sqm 659.0 0.0 0.0 0.0 0.0 Terrace 0.0 Sqm 659.0 0.0 0.0 0.0 0.0 Second Floor 0.0 Sqm 659.0 0.0 0.0 0.0 0.0 Third Floor 0.0 Sqm 659.0 0.0 0.0 0.0 0.0 Fourth Floor 0.0 Sqm 659.0 0.0 0.0 0.0 0.0 Fifth Floor 0.0 Sqm 659.0 0.0 0.0 0.0 0.0 SiXth Floor 0.0 Sqm 659.0 0.0 0.0 0.0 0.0 PLINTH PROTECTION 0.0 0.0 0.0 0.0 0.0 Making plinth protection 100 mm thick using of M20 grade cement concrete necessary excavation, levelling & dressing & finishing the top smooth. 0.0 0.0 0.0 0.0 0.0 (a)Ground Floor 0.0 cum 6473.700000000001 0.0 0.0 0.0 0.0 0.0 0.0 0.0 |
| 232 | Providing average 25mm thick grading Concrete in C.C ( 1:2:2 ) using 6mm size crusher broken black hard granite chips using 2% water proofing cement compound of approved make after scraping and cleaning the roof surface and finishing smooth to proper slope and gradient including cost of all materials, conveyance, sundries,T&P watering and curing by ponding water over terrace slab etc. complete as per the direction of the Engineer-in-charge. Terrace 1770.98 1770.98 Sqm 421.5 746468.0700000001 0.0 746468.0700000001 Terrace 0.0 Sqm 462.0 0.0 0.0 0.0 0.0 Second Floor 0.0 Sqm 508.5 0.0 0.0 0.0 0.0 Third Floor 0.0 Sqm 562.0 0.0 0.0 0.0 0.0 Fourth Floor 0.0 Sqm 623.5 0.0 0.0 0.0 0.0 Fifth Floor 0.0 Sqm 694.2 0.0 0.0 0.0 0.0 SiXth Floor 0.0 Sqm 775.5 0.0 0.0 0.0 0.0 Providing and Laying of 2.5 cm. Damp proof course with C.C. (1:2:4) using 12mm. Size hard broken granite Chips including cost of all materials, conveyance, loading, unloading, royalties, taxes, cost of labours, T&P, hire & running charges for all leads as per direction of the engineer-in-charge. 0.0 0.0 0.0 0.0 0.0 Ground Floor 0.0 Sqm 386.6 0.0 0.0 0.0 0.0 Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. 0.0 0.0 0.0 0.0 0.0 Ground Floor 0.0 Kg 96.0 0.0 0.0 0.0 0.0 Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. (Mild steel tubes hot finished seamless type) 0.0 0.0 0.0 0.0 0.0 Ground Floor 0.0 KG 146.63 0.0 0.0 0.0 0.0 Supplying, filling, spreading & leveling stone boulders of size range 40 mm in recharge pit of required thickness including cost of material, labour, carriage, royalty, etc complete as directed by the Engineer-in-charge. 0.0 0.0 0.0 0.0 0.0 Ground Floor 0.6749999999999997 0.6749999999999997 Cum 2156.4 1455.5699999999995 0.0 0.0 0.0 Supplying, filling, spreading & leveling stone boulders of size range 20 mm in recharge pit of required thickness including cost of material, labour, carriage, royalty, etc complete as directed by the Engineer-in-charge. 0.0 0.0 0.0 0.0 0.0 Ground Floor 0.6749999999999997 0.6749999999999997 Cum 2605.9 1758.9824999999994 0.0 0.0 0.0 Supplying and fixing Rain Water Harvesting System including gutters, pipes, filters, and storage tanks, machinaries, as well as installation charges etc complete as directed by the Engineer-in-charge. 0.0 0.0 0.0 0.0 0.0 2.0 2.0 Each 50000.0 100000.0 0.0 0.0 0.0 FINISHING WORK 0.0 0.0 0.0 0.0 0.0 0.0 0.0 |
| 233 | Supplying and finishing the plastered surface of wall using 2 Coats of Cement Based Wall Putty (Water Based) of approved make and quality and finished smooth and even surface to receive the paint including the cost of all materials, cost of all labour, conveyance, taxes, loading, unloading, scaffolding, T&P, etc, all complete as per the direction of Engineer-in-Charge. Interior Wall Putty 0.0 0.0 0.0 0.0 Ground Floor 4897.6 4897.6 Sqm 88.1 431478.56 0.0 0.0 431478.56 Terrace 0.0 0.0 Sqm 90.0 0.0 0.0 0.0 0.0 Second Floor 0.0 Sqm 92.0 0.0 0.0 0.0 0.0 Third Floor 0.0 Sqm 94.1 0.0 0.0 0.0 0.0 Fourth Floor 0.0 Sqm 96.2 0.0 0.0 0.0 0.0 Fifth Floor 0.0 Sqm 98.4 0.0 0.0 0.0 0.0 SiXth Floor 0.0 Sqm 100.6 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 Outer Wall Putty 0.0 0.0 0.0 0.0 0.0 Ground Floor 0.0 Sqm 0.0 0.0 0.0 0.0 0.0 Terrace 0.0 Sqm 0.0 0.0 0.0 0.0 0.0 Second Floor 0.0 Sqm 0.0 0.0 0.0 0.0 0.0 Third Floor 0.0 Sqm 0.0 0.0 0.0 0.0 0.0 Fourth Floor 0.0 Sqm 0.0 0.0 0.0 0.0 0.0 Fifth Floor 0.0 Sqm 0.0 0.0 0.0 0.0 0.0 SiXth Floor 0.0 Sqm 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 |
| 234 | Providing and applying 2 coats plastic emulsion paint of approved quality and shade over a coat of wall primer of approved quality to surfaces (interior) including throughly brushing the surface free from foreign materials, sand papering smooth the intermediate coats, providing necessary putty & primer including of all materials, labour, conveyance,royalties, scaffolding, watering, curing, sundries, tools and plants etc as per the direction of Engineer-in-charge. (colour & shade to be approved before procurment & use) Ground Floor 4920.17 4920.17 Sqm 194.1 955004.997 0.0 0.0 955004.997 First Floor 847.92 847.92 Sqm 198.4 168227.328 0.0 168227.328 0.0 Second Floor 0.0 Sqm 202.81 0.0 0.0 0.0 0.0 Third Floor 0.0 Sqm 207.3 0.0 0.0 0.0 0.0 Fourth Floor 0.0 Sqm 212.0 0.0 0.0 0.0 0.0 Fifth Floor 0.0 Sqm 216.8 0.0 0.0 0.0 0.0 SiXth Floor 0.0 Sqm 221.8 0.0 0.0 0.0 0.0 |
| 235 | Providing and Painting with Two Coats Weather Coat Paint (exterior grade) of approved make & shade manufactured by reputed manufacturer make an even finished surface over a coat of water bound cement primer in all heights with all scaffolding and staging charges including cost, conveyance, cost of all labours, T & P, sundries etc. as required for the work complete. Ground Floor 2452.57 302.93 2755.5 Sqm 186.2 513074.1 56405.566 0.0 456668.534 First Floor 532.8 532.8 Sqm 193.3 102990.23999999999 0.0 102990.23999999999 0.0 Second Floor 0.0 Sqm 200.8 0.0 0.0 0.0 0.0 Third Floor 0.0 Sqm 208.7 0.0 0.0 0.0 0.0 Fourth Floor 0.0 Sqm 216.9 0.0 0.0 0.0 0.0 Fifth Floor 0.0 Sqm 225.6 0.0 0.0 0.0 0.0 SiXth Floor 0.0 Sqm 234.7 0.0 0.0 0.0 0.0 |
| 236 | Painting two coats of synthetic enamel paint over Iron Works as per approved shade of approved quality over a coat of primer, sand papering, polishing the surface including cost, conveyance,labour, T&P, scaffolding etc. as required for the work complete as per direction of Engineer-in-charge. (The paints and primer are to be approved before procurement and use) Ground Floor 118.38 33.38 1.62 153.38 Sqm 268.7 41213.206 8969.206 0.0 31808.706 First Floor 17.22 17.22 Sqm 273.6 4711.392 0.0 4711.392 0.0 Second Floor 0.0 Sqm 278.6 0.0 0.0 0.0 0.0 Third Floor 0.0 Sqm 283.7 0.0 0.0 0.0 0.0 Fourth Floor 0.0 Sqm 289.0 0.0 0.0 0.0 0.0 Fifth Floor 0.0 Sqm 294.5 0.0 0.0 0.0 0.0 SiXth Floor 0.0 Sqm 300.1 0.0 0.0 0.0 0.0 Painting two coats of synthetic enamel paint on road work over Plaster or RCC Works like (kerb wall,bridge rcc barrier) as per approved shade of approved quality , sand papering, polishing the surface including cost, conveyance,labour, T&P, scaffolding et 0.0 0.0 0.0 0.0 0.0 Ground Floor 0.0 Sqm 84.5 0.0 0.0 0.0 0.0 Wall painting with Textured Paint of approved quality of pattern as specified in drawing including cost of all materials, labours ,T&P, carriage, royalty, taxes etc. required for the work all complete as per direction of Engineer-in-charge. 0.0 0.0 0.0 0.0 0.0 Ground Floor 0.0 Sqm 799.1 0.0 0.0 0.0 0.0 First Floor 0.0 Sqm 799.1 0.0 0.0 0.0 0.0 Second Floor 0.0 Sqm 799.1 0.0 0.0 0.0 0.0 Third Floor 0.0 Sqm 799.1 0.0 0.0 0.0 0.0 Fourth Floor 0.0 Sqm 799.1 0.0 0.0 0.0 0.0 Fifth Floor 0.0 Sqm 799.1 0.0 0.0 0.0 0.0 SiXth Floor 0.0 Sqm 799.1 0.0 0.0 0.0 0.0 FLOORING WORK 0.0 0.0 0.0 0.0 |
| 237 | Providing and laying of 600 mm x 600 mm Polished Vitrified floor tiles of premium grade having thickness 8 mm to 10mm conforming to IS 15622:2006 (GrPlain (Ivory) oup-B la) of following sizes. of approved make, quality and colour without any warpage laid over an under layer of 20 mm thick base of cement mortar (1:4) (1 cement: 4 coarse sand) including cutting to size, laying and filling the joints with white cement slurry mixed with colouring pigment to match the shade and colour, cleaning the surfaces including the cost of all materials, cost of all labour, conveyance, royalties, loading, unloading, sundries, watering and curing, T&P, etc. complete as per the direction of the Engineer-in-Charge.(Note- Sample of tiles shall be approved before procurement and use.) Ground Floor 1313.905625 1313.905625 Sqm 1143.3 1502188.3010625 0.0 0.0 1502188.3010625 First Floor 0.0 Sqm 1157.1 0.0 0.0 0.0 0.0 Second Floor 0.0 Sqm 1171.5 0.0 0.0 0.0 0.0 Third Floor 0.0 Sqm 1186.6 0.0 0.0 0.0 0.0 Fourth Floor 0.0 1202.5 0.0 0.0 0.0 0.0 Fifth Floor 0.0 1219.2 0.0 0.0 0.0 0.0 SiXth Floor 0.0 1236.7 0.0 0.0 0.0 0.0 0.0 0.0 0.0 |
| 238 | Providing and laying of 600 mm x 600 mm Anti skid matt finish Vitrified floor tiles of premium grade having thickness 8 mm to 10mm conforming to IS 15622:2006 (Group-B la) of following sizes. of approved make, quality and colour without any warpage laid over an under layer of 20 mm thick base of cement mortar (1:4) (1 cement: 4 coarse sand) including cutting to size, laying and filling the joints with white cement slurry mixed with colouring pigment to match the shade and colour, cleaning the surfaces including the cost of all materials, cost of all labour, conveyance, royalties, loading, unloading, sundries, watering and curing, T&P, etc. complete as per the direction of the Engineer-in-Charge.(Note- Sample of tiles shall be approved before procurement and use.) 0.0 0.0 0.0 |
| 239 | Providing and laying 300mmx300mm printed series ceramic floor tiles of premium grade having thickness 7mm to 8mm conforming to IS 13755 of approved make, quality and colour without any warpage laid over an under layer of 20 mm thick base of cement mortar (1:4) (1 cement: 4 coarse sand) including cutting to size, laying and spacer of 4mm for grouting the joints of tiles using epoxy grout mix of 0.70 kg of organic coated filler of desired shade (0.10 kg of hardener and 0.20 kg of resin per kg) to match the shade and colour, cleaning the surfaces with acid including the cost of all materials, cost of all labour, conveyance, royalties, loading, unloading, sundries, watering and curing, T&P, etc. complete as per the direction of the Engineer-in-Charge.(Note- Sample of tiles shall be approved before procurement and use.) Ground Floor 80.91 80.91 Sqm 1097.1 88766.36099999999 0.0 0.0 88766.36099999999 First Floor 0.0 Sqm 1110.8 0.0 0.0 0.0 0.0 Second Floor 0.0 Sqm 1125.3 0.0 0.0 0.0 0.0 Third Floor 0.0 Sqm 1140.4 0.0 0.0 0.0 0.0 Fourth Floor 0.0 Sqm 1156.3 0.0 0.0 0.0 0.0 Fifth Floor 0.0 Sqm 1173.0 0.0 0.0 0.0 0.0 SiXth Floor 0.0 Sqm 1190.5 0.0 0.0 0.0 0.0 0.0 0.0 0.0 |
| 240 | Providing & laying Heavy Duty Industrial Vetrified Tile having thickness 8 mm to 10mm in floor/dado/skirting confirming to IS : 15622 of size 300mmx300mm of approved make, quality and colour without any warpage laid over an under layer of 12mm thick cement mortar (1:3) (1 cement: 3 coarse sand) confirming to IS-1443 including cutting to size, laying and filling the joints with white cement slurry mixed with colouring pigment to match the shade and colour, cleaning the surfaces including the cost of all materials, cost of all labour, conveyance, taxes, royalties, loading, unloading, sundries, watering and curing, T&P, etc. complete as per the direction of the Engineer-in-Charge.(Note- Sample of tiles shall be approved before procurement and use.) Ground Floor 54.13 54.13 Sqm 1195.4 64707.00200000001 0.0 0.0 64707.00200000001 Providing and laying Chequred Tiles. tiles confirming to IS : 15622 of approved make, quality and colour without any warpage laid over 20 mm thick base of cement mortar (1:4) (1 cement: 4 coarse sand) including cutting to size, laying and filling the joints with white cement slurry mixed with colouring pigment to match the shade and colour, cleaning the surfaces including the cost of all materials, cost of all labour, conveyance, taxes, royalties, loading, unloading, sundries, watering and curing, T&P, etc. complete as per the direction of the Engineer-in-Charge.(Note- Sample of tiles shall be approved before procurement and use.) 0.0 0.0 0.0 0.0 Ground Floor 0.0 Sqm 656.0 0.0 0.0 0.0 0.0 First Floor 0.0 Sqm 669.7 0.0 0.0 0.0 0.0 Providing & laying granite stone flooring using 19-20 mm thick granite stone slab of approved quality, colour and size above 0.4 Sqm as per IS 14223 in Stair Treads and Risers over an under layer of 20 mm thick cement mortar (1:4) (1 cement: 4 coarse sand) confirming to IS-1443 including cutting to size, laying and joining with white cement slurry and colouring pigment to match the shade with typical half nosing and cutting grooves etc including cost of all labour, materials, royalties, loading and unloading, conveyance, sundries, watering and curing, etc. complete as per the direction of the Engineer-in-Charge. (Note- Sample of granite tiles shall be approved before procurement and use.) 0.0 0.0 0.0 0.0 Ground Floor 0.0 Sqm 3201.7 0.0 0.0 0.0 0.0 First Floor 0.0 Sqm 3234.9 0.0 0.0 0.0 0.0 Second Floor 0.0 Sqm 3269.8 0.0 0.0 0.0 0.0 Third Floor 0.0 Sqm 3306.4 0.0 0.0 0.0 0.0 Fourth Floor 0.0 Sqm 3344.8 0.0 0.0 0.0 0.0 Fifth Floor 0.0 Sqm 3385.2 0.0 0.0 0.0 0.0 SiXth Floor 0.0 Sqm 3427.6 0.0 0.0 0.0 0.0 |
| 241 | Providing & laying granite stone flooring in Floors and landing using 19-20 mm thick granite stone slab of approved quality, colour and size above 0.4 Sqm as per IS 14223 laid over an under layer of 20 mm thick cement mortar (1:4) (1 cement: 4 coarse sand) confirming to IS-1443 including cutting to size, laying and filling the joints with white cement slurry mixed with colouring pigment to match the shade and colour, cleaning the surfaces including the cost of all materials, cost of all labour, conveyance, royalties, loading, unloading, sundries, watering and curing, T&P, etc. complete as per the direction of the Engineer-in-Charge.(Note- Sample of granite tiles shall be approved before procurement and use.) Ground Floor 14.35 14.35 Sqm 3145.4 45136.49 0.0 0.0 45136.49 First Floor 0.0 Sqm 3175.8 0.0 0.0 0.0 0.0 Second Floor 0.0 Sqm 3207.7 0.0 0.0 0.0 0.0 Third Floor 0.0 Sqm 3241.2 0.0 0.0 0.0 0.0 Fourth Floor 0.0 3276.4 0.0 0.0 0.0 0.0 Fifth Floor 0.0 3313.3 0.0 0.0 0.0 0.0 SiXth Floor 0.0 3352.1 0.0 0.0 0.0 0.0 Providing & laying granite stone tiles in dado/skirting using 10mm thick granite stone slab of approved quality, colour and size upto 0.4 Sqm as per IS 14223 to proper line, level and slope laid over 12mm thick cement mortar (1: 3) confirming to IS IS-1443 including cutting to size, laying and filling the joints with white cement slurry mixed with colouring pigment to match the shade and colour, cleaning the surfaces including the cost of all materials, cost of all labour, conveyance, royalties, loading, unloading, sundries, watering and curing, T&P, etc. complete as per the direction of the Engineer-in-Charge.(Note- Sample of granite tiles shall be approved before procurement and use.) 0.0 0.0 0.0 0.0 0.0 Ground Floor 0.0 Sqm 2527.0 0.0 0.0 0.0 0.0 First Floor 0.0 Sqm 2570.7 0.0 0.0 0.0 0.0 Second Floor 0.0 Sqm 2616.6 0.0 0.0 0.0 0.0 Third Floor 0.0 Sqm 2664.7 0.0 0.0 0.0 0.0 Fourth Floor 0.0 Sqm 2715.3 0.0 0.0 0.0 0.0 Fifth Floor 0.0 Sqm 2768.4 0.0 0.0 0.0 0.0 SiXth Floor 0.0 Sqm 2824.2 0.0 0.0 0.0 0.0 0.0 0.0 0.0 |
| 242 | Providing & laying kota stone slabs in floors using 16 mm thick kota stone slab of approved quality, colour and size above 0.10 Sqm laid over an under layer of 20 mm thick cement mortar (1:4) (1 cement : 4 coarse sand) confirming to IS-1443 including cutting to size, laying and filling the joints with white cement slurry mixed with colouring pigment to match the shade and colour, cleaning the surfaces including the cost of all materials, cost of all labour, conveyance, taxes, royalties, loading, unloading, sundries, watering and curing, T&P, etc. complete as per the direction of the Engineer-in-Charge.(Note- Sample of tiles shall be approved before procurement and use.) Ground Floor 184.63625000000002 184.63625000000002 Sqm 1288.6 237922.27175 0.0 0.0 237922.27175 First Floor 0.0 Sqm 1319.0 0.0 0.0 0.0 0.0 Second Floor 0.0 Sqm 1350.9 0.0 0.0 0.0 0.0 Mumty Floor 0.0 Sqm 1384.4 0.0 0.0 0.0 0.0 0.0 0.0 0.0 DADO/SKIRTING WORK 0.0 0.0 0.0 |
| 243 | Providing and laying of Polished Vitrified floor tiles of premium grade having thickness 8 mm to 10mm conforming to IS 15622:2006 (GrPlain (Ivory) oup-B la) in dado/skirting confirming to IS : 15622 of approved make, quality, colour and size 600mm x600mm Ground Floor 136.8465 136.8465 Sqm 1279.9 175149.83535 0.0 0.0 175149.83535 First Floor 0.0 Sqm 1300.6 0.0 0.0 0.0 0.0 Second Floor 0.0 Sqm 1322.2 0.0 0.0 0.0 0.0 Third Floor 0.0 Sqm 1345.0 0.0 0.0 0.0 0.0 Fourth Floor 0.0 1368.9 0.0 0.0 0.0 0.0 Fifth Floor 0.0 1394.0 0.0 0.0 0.0 0.0 SiXth Floor 0.0 1420.4 0.0 0.0 0.0 0.0 0.0 0.0 0.0 |
| 244 | Ceramic wall tile With Epoxy Grout For ToiletProviding and laying of printed series ceramic floor tiles of premium grade having thickness 7mm to 8mm conforming to IS 13755 in dado/skirting confirming to IS : 15622 of approved make, quality, colour and size 300mm x 300mm upto required height from floor level fixed over an under layer of 12mm thick bed of cement mortar (1:3) (1 Cement : 3 Coarse sand) including cutting to size, laying and spacer of 4mm for grouting the joints of tiles using epoxy grout mix of 0.70 kg of organic coated filler of desired shade (0.10 kg of hardener and 0.20 kg of resin per kg) to match the shade and colour, cleaning the surfaces with acid including the cost of all materials, cost of all labour, conveyance, taxes, royalties, loading, unloading, sundries, watering and curing, T&P, etc. complete as per the direction of the Engineer-in-Charge.(Note- Sample of tiles shall be approved before procurement and use.) Ground Floor 319.18 319.18 Sqm 1174.7 374940.74600000004 0.0 0.0 374940.74600000004 First Floor 0.0 Sqm 1195.4 0.0 0.0 0.0 0.0 Second Floor 0.0 Sqm 1217.1 0.0 0.0 0.0 0.0 Third Floor 0.0 Sqm 1239.8 0.0 0.0 0.0 0.0 Fourth Floor 0.0 Sqm 1263.7 0.0 0.0 0.0 0.0 Fifth Floor 0.0 Sqm 1288.8 0.0 0.0 0.0 0.0 SiXth Floor 0.0 Sqm 1315.2 0.0 0.0 0.0 0.0 Ceramic wall tile Without Epoxy GroutProviding and laying of Glazed Ceramic Wall Tiles in dado/skirting confirming to IS : 15622 of approved make, quality, colour and size 400mm x 300mm upto required height from floor level fixed over an under layer of 12mm thick bed of cement mortar (1:3) (1 Cement : 3 Coarse sand) including cutting to size, laying and filling the joints with white cement slurry mixed with colouring pigment to match the shade and colour, cleaning the surfaces including the cost of all materials, cost of all labour, conveyance, taxes, royalties, loading, unloading, sundries, watering and curing, T&P, etc. complete as per the direction of the Engineer-in-Charge.(Note- Sample of tiles shall be approved before procurement and use.) 0.0 0.0 0.0 0.0 0.0 Ground Floor 0.0 Sqm 998.6 0.0 0.0 0.0 0.0 First Floor 0.0 Sqm 1019.2 0.0 0.0 0.0 0.0 Second Floor 0.0 Sqm 1040.9 0.0 0.0 0.0 0.0 Mumty Floor 0.0 Sqm 1063.7 0.0 0.0 0.0 0.0 0.0 0.0 0.0 |
| 245 | Providing & laying kota stone slabs in dado/Skirting using 16 mm thick Kota stone of approved quality, colour and size above 0.10 Sqm laid over an under layer of 12mm thick cement mortar (1:3) (1 cement: 3 coarse sand) confirming to IS-1443 including cutting to size, laying and filling the joints with white cement slurry mixed with colouring pigment to match the shade and colour, cleaning the surfaces including the cost of all materials, cost of all labour, conveyance, taxes, royalties, loading, unloading, sundries, watering and curing, T&P, etc. complete as per the direction of the Engineer-in-Charge.(Note- Sample of tiles shall be approved before procurement and use.) Ground Floor 49.367699999999985 49.367699999999985 Sqm 1565.4 77280.19757999998 0.0 0.0 77280.19757999998 First Floor 0.0 Sqm 1609.1 0.0 0.0 0.0 0.0 Second Floor 0.0 Sqm 1655.0 0.0 0.0 0.0 0.0 Mumty Floor 0.0 Sqm 1703.2 0.0 0.0 0.0 0.0 BUILT IN JOINERIES 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 |
| 246 | Providing edge moulding and groove cutting in granite tiles as per drawing and design for granite stone counters, steps, Vanities etc., including machine polishing to edge to give high gloss finish etc. complete as per direction of Engineer-in-Charge. 0.0 0.0 0.0 DOOR & CHOUKATH WORKS 0.0 0.0 0.0 |
| 247 | Providing and fixing 65mm X 125mm factory made single extruded WPC (Wood Polymer Composite) solid door/window/Ceosetory windows & other Frames/Chowkhat comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modulus of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with M.S hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-In- Charge.Note: For WPC solid door/window frames, minus 5mm tolerance in dimensions i.e depth and width of profile shall be acceptable. Variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be made. Ground Floor 234.55 234.55 Rmt 1252.4 293750.42000000004 0.0 0.0 293750.42000000004 First Floor 0.0 Rmt 1252.4 0.0 0.0 0.0 0.0 Second Floor 0.0 Rmt 1252.4 0.0 0.0 0.0 0.0 Third Floor 0.0 Rmt 1252.4 0.0 0.0 0.0 0.0 Fourth Floor 0.0 Rmt 1252.4 0.0 0.0 0.0 0.0 Fifth Floor 0.0 Rmt 1252.4 0.0 0.0 0.0 0.0 SiXth Floor 0.0 Rmt 1252.4 0.0 0.0 0.0 0.0 Supplying, fitting and fixing of 32mm thick flush door shutter with approved quality of 30mm thick BWR block board pasted with 1mm thick sunmica on both side of approved design and quality including cost of all door fittings and fixtures etc. complete 0.0 0.0 0.0 0.0 0.0 Ground Floor 0.0 Sqm 10668.61 0.0 0.0 0.0 0.0 First Floor 0.0 Sqm 10668.61 0.0 0.0 0.0 0.0 Second Floor 0.0 Sqm 10668.61 0.0 0.0 0.0 0.0 Third Floor 0.0 Sqm 10668.61 0.0 0.0 0.0 0.0 Fourth Floor 0.0 Sqm 10668.61 0.0 0.0 0.0 0.0 Fifth Floor 0.0 Sqm 10668.61 0.0 0.0 0.0 0.0 SiXth Floor 0.0 Sqm 10668.61 0.0 0.0 0.0 0.0 |
| 248 | Providing and fixing 45mm X 75mm or 90 mm x 50 mm factory made single extruded WPC (Wood Polymer Composite) solid door/window/Ceosetory windows & other Frames/Chowkhat comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modulus of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with M.S hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-In- Charge.Note: For WPC solid door/window frames, minus 5mm tolerance in dimensions i.e depth and width of profile shall be acceptable. Variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be made. Ground Floor 74.25 74.25 Rmt 720.96 53531.280000000006 0.0 0.0 53531.280000000006 First Floor 0.0 Rmt 720.96 0.0 0.0 0.0 0.0 Second Floor 0.0 Rmt 720.96 0.0 0.0 0.0 0.0 Mumty Floor 0.0 Rmt 720.96 0.0 0.0 0.0 0.0 |
| 249 | Providing and fixing factory made single extruded 30 MM THICK WPC (Wood Polymer Composite) solid plain flush door shutter of required size comprising of virgin polymer of K value 58-60(Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheathusk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimumdensity of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge),minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistanceto spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required sizewith necessary full body threaded star headed counter sunk S.S screws, all as per directionof Engineer-In- Charge.(Make: WPC: Century / Black Cobra / Rajshri Plastiwood, Hardware Fittings: Godrej / Dorset / Link / Dorma) Ground Floor 23.63 23.63 Sqm 4106.26 97030.9238 0.0 0.0 97030.9238 |
| 250 | Providing and fixing factory made single extruded 35 MM THICK WPC (Wood Polymer Composite) solid plain flush door shutter of required size comprising of virgin polymer of K value 58-60(Suspension Grade), calcium carbonate and natural fibers (wood powder/ Ground Floor 104.48 104.48 Sqm 4961.3 518356.624 0.0 0.0 518356.624 First Floor 0.0 Sqm 4961.3 0.0 0.0 0.0 0.0 Mumty Floor 0.0 Sqm 4961.3 0.0 0.0 0.0 0.0 Supplying and fitting-fixing of factory made single leaf rigid FRP (alternately called GRP) sandwich composite door shutter of 32mm thick laminated with two GRP skins with wood grain finish fabricated using UV-stabilised Isopthalic Gelcoat and one layer of 450 gsm E-glass Chopped Strand Mat (CSM) impregnated with orthopthalic palyester resin. The thickness of the skins shall not be less than 3.00 mm Expanded Polystyrone(EPS) structural foam panel of 29mm thickness and a density of 20kg/cu.mtr shall be used as core material. Wooden reinforcements made of seasoned sal wood block of cross section not less than 28mmx32mm and also necessary sal wood reinforcements for fitting the metal fittings such as tower bolts, aldrops, handles etc shall be provided. A structural adhesive compatible with (EPS) foam shall be used for bending the core material, the sal wood reiforcements and the skins. The material and process for manufacturing the door shutters shall conform to RV-TIFAC composites Design Centre's standards and specifications and the door shutters tested in conformation to IS: 4020-1998. The finish of door shutter will be plain colour white/ Ivory/ Beige/ Light grey/ Mahogany/ Teak wood or any other colour using high quality pigments. Three heavy whight mild steel butt hinges type-I(ISI marked) size 100mm are to be fitted on one side of shutter. 0.0 0.0 0.0 0.0 0.0 Ground Floor 0.0 Sqm 6172.1 0.0 0.0 0.0 0.0 First Floor 0.0 Sqm 6172.1 0.0 0.0 0.0 0.0 Second Floor 0.0 Sqm 6172.1 0.0 0.0 0.0 0.0 Third Floor 0.0 Sqm 6172.1 0.0 0.0 0.0 0.0 Fourth Floor 0.0 Sqm 6172.1 0.0 0.0 0.0 0.0 Fifth Floor 0.0 Sqm 6172.1 0.0 0.0 0.0 0.0 SiXth Floor 0.0 Sqm 6172.1 0.0 0.0 0.0 0.0 Providing and fixing factory made 2.5 track KOMMERLING UPVC white colour sliding window with SS mesh comprising of uPVC multi-chambered frame having section Frame 88mm x 49mm, Window sash: 37mm x 61mm, Bugmesh sash: 58mm x 32mm made out of lead free green profiles with comers fusion welded, fully reinforced with Galvanized steel 1.5 mm. The windows profile should fulfill the requirements of Viny 2010. The physical properties of the profiles like Vicat softening temperature, density, tensile strength, hardness, weatherability, impact strength and Modulus of Elasticity should be tested in accordance with ASTM/DIN-ISO standards and the thermal conductivity as per IS standards. The window comprising of uPVC extruded glazing beads of appropriate dimension, EPDM gasket, G.I fasteners 100 x 8 mm size for fixing frame to finished wall, plastic packers, plastic caps and necessary stainless steel screws etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of required size. The sash will be fitted with 5mm clear glass 0.0 0.0 0.0 0.0 0.0 Ground Floor 0.0 Sqm 8900.0 0.0 0.0 0.0 0.0 First Floor 0.0 Sqm 8900.0 0.0 0.0 0.0 0.0 Second Floor 0.0 Sqm 8900.0 0.0 0.0 0.0 0.0 Third Floor 0.0 Sqm 8900.0 0.0 0.0 0.0 0.0 Fourth Floor 0.0 Sqm 8900.0 0.0 0.0 0.0 0.0 Fifth Floor 0.0 Sqm 8900.0 0.0 0.0 0.0 0.0 SiXth Floor 0.0 Sqm 8900.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 |
| 251 | Supplying and fixing of Powder coated 50-60 microns approved colour of aluminium 40mm Casement series Door Unit with suitable aluminium extrude profiles. the system is designed to accommodate 12mm clear toughened glass. the rate quoted inclusive of hardwares like antilift, roller, Espag lock cum handle, epdm gaskets, T mullion, Fly Mullion, bottom adopter, mid transom, glazing clip for 12 mm glass felt along with all accessories etc complete. The gap between the wall and window will be filled with silicon weather sealant in the outer side. including the cost of all materials ,hardware fittings,cost of all labour, conveyance, loading, un loading, T&P, etc, complete as per the direction of Engineer-in Charge.(As per Proceeding of C.C.E. Level committee meeting held on dt. 12.02.2024 at 11.30 A.M.) Ground Floor 8.64 8.64 Sqm 12427.8 107376.192 0.0 0.0 107376.192 0.0 0.0 0.0 WINDOW & VENTILATOR WORKS 0.0 0.0 0.0 0.0 0.0 0.0 |
| 252 | Supplying , fitting and fixing of two track UPVC sliding window of approved make with 6mm thick glass of approved quality complete with frame, shutters and all fitting and fixtures.. complete in all respect as per the direction of the Engineer-in-Charge. Ground Floor 149.02 149.02 Sqm 4960.97 739283.7494000001 0.0 0.0 739283.7494000001 First Floor 0.0 Sqm 4960.97 0.0 0.0 0.0 0.0 Second Floor 0.0 Sqm 4960.97 0.0 0.0 0.0 0.0 Third Floor 0.0 Sqm 4960.97 0.0 0.0 0.0 0.0 Fourth Floor 0.0 Sqm 4960.97 0.0 0.0 0.0 0.0 Fifth Floor 0.0 Sqm 4960.97 0.0 0.0 0.0 0.0 SiXth Floor 0.0 Sqm 4960.97 0.0 0.0 0.0 0.0 0.0 0.0 0.0 |
| 253 | Supplying and fitting -fixing of Un-plasticised poly Vinyl Chloride (UPVC) (FENESTA/NCL VECCA LTD) Ventillator/Top Hung-60 Series duly manufactured using UPVC reinforced Profiles of 60mmx 55mmx2.5mm for outer frames ,75mmx60mmx2.25mm for casement window sash profile capable of mounting single glazing system,structurally reinforced with hot dip galvanised upto 50 microns of minimum thickness of 1.5 mm prefabricted and welded through fusion welding the wwindow sash shall be fitted with 6mm thick clear toughened glass of Saint-Gobain make duly fixed with EPDM weathering seal resistant accessories like clipping locking system made of aluminium 1 no per set of sashes and the system to be installed at the site using anchor fasteners,silicon rubber sealant,easy glazing/deglazing at siteetc including cost and conveyance of all accessories labour charges,materials and product confirming to ASTM D 638-14,EN-477-95 and other applicable codes and standards. Ground Floor 6.48 6.48 Sqm 7115.0 46105.200000000004 0.0 0.0 46105.200000000004 Supplying, fitting and fixing of UPVC Partition Wall I60 Casement Series 1-OFF as per drawing and specification: Top member-6mm Tinted/Laminated/Colored/Clear Toughened Glass & Bottom member-PVC Sheet (12-18mm), Weight: 291.36 kg, Colour-White Dimension Type-Frame Size from RO, Frame Depth-60mm, Hinged Series-I60 Casement, Reinforcement-Full, Coupling 180-33mm/2108-3106+56016-10070, Window O/F-55mm/41101-11000+R1, Frame T/M-74mm/41101-12000/12100+56016-10001, T-Joins-Mechanical, Frame Mech-50502-11016, Connector-Shape 1, Bead Shape-Glazing Packer 16.5 x 77 x 5 mm, Cmnt Gl Packer-No, Grill required-Supply & Install, Supply Type-280ml bottle, Silicon Sealant-No, Display Fixings-Face with drainage including scaffolding complete in all respect as per the direction of the Engineer-in-Charge. 0.0 0.0 0.0 0.0 0.0 Ground Floor 0.0 Sqm 4142.68 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 Providing and fixing 12 mm thick frame less toughened glass partition Dorma Premium (911298) PT 90 Side Connector and PT 80 Glass to glass Connector with Silicone,12mm Clear Toughened Glass with Cutout and Hole,including perimeter sealing of glass to glass joints with silicon sealant ,etc.as per drawing and specification including the cost of all materials ,T&P,etc all complete as per the direction of Engineer-in-Charge. 0.0 0.0 0.0 0.0 0.0 Ground Floor 0.0 Sqm 10223.2 0.0 0.0 0.0 0.0 Providing and fixing of 12mm thick Clear Toughened Glass Frameless Door With Dorma Premium Fittings. Dorma Premium (9111198) Unilite Package BTS 75 UL PT 10 with Cover, UL PT 20 with Cover UL US 10 Luck with Cover and PT. 24. Dorma Premium (9137121) H Type Handle 450mm, 12mm Clear Toughened Glass with Cutout and Hole including the cost of ali materials hardware fittings, cost of all labour, conveyance. loading, unloading. T&P, etc, complete as per the direction of Engineer-in-Charge 0.0 0.0 0.0 0.0 0.0 Ground Floor 0.0 Sqm 11343.2 0.0 0.0 0.0 0.0 0.0 0.0 0.0 STRUCTURAL STEEL & GLAZING WORKS 0.0 0.0 0.0 |
| 254 | Supplying, fitting & fixing of M.S grills for (windows, ventilators & grill gates) madeout of M.S angle/M.S flat/M.S solid bar/M.S sections including cost of screws as per approved design & dimensions, electrically welded properly with all locking arrangrments including cost of materials, labour, carriage etc. complete as per the direction of the Engineer-in-Charge. Ground Floor 4640.0 1668.75 32.400000000000006 6341.15 Kg 89.43 567089.0445 149236.3125 0.0 414955.2 Terrace 344.4 344.4 Kg 89.43 30799.692 0.0 30799.692 0.0 Second Floor 0.0 Kg 89.43 0.0 0.0 0.0 0.0 Third Floor 0.0 Kg 89.43 0.0 0.0 0.0 0.0 Fourth Floor 0.0 Kg 89.43 0.0 0.0 0.0 0.0 Fifth Floor 0.0 Kg 89.43 0.0 0.0 0.0 0.0 SiXth Floor 0.0 Kg 89.43 0.0 0.0 0.0 0.0 S.S Railing 0.0 0.0 0.0 0.0 |
| 255 | Supplying, fabricating & fixing of polished stainless steel (304 grade) items made out of pipes, angles, flats, plates, hollow tube, square pipe bracing as per approved design and specification, buffing, polishing etc. with cost, conveyance, labour in railing, parapet, staircase, space frame etc required for the work complete in all respect as per direction of Engineer-in-charge. Ground Floor 403.1 403.1 Kg 343.8 138585.78 0.0 0.0 138585.78 Terrace 0.0 Kg 343.8 0.0 0.0 0.0 0.0 Second Floor 0.0 Kg 343.8 0.0 0.0 0.0 0.0 Third Floor 0.0 Kg 343.8 0.0 0.0 0.0 0.0 Fourth Floor 0.0 Kg 343.8 0.0 0.0 0.0 0.0 Fifth Floor 0.0 Kg 343.8 0.0 0.0 0.0 0.0 SiXth Floor 0.0 Kg 343.8 0.0 0.0 0.0 0.0 G.R.C. JALI :-Providing and fixing Glass Reinforced Concrete (GR.C) Screens in approved size pattern, design, shadeand thickness of 50mm on frame and design element in 30mm thick have weight approximately between 3.5 4 Kg per Sq Ft and color of M/S UniStone make or equivalent. The above weight and thickness is considering dimensions of screens up to 2133mm in height and 1219mm in width and having at least 50% void space. The screens should be made from '53 grade' White Portland Cement manufactured by JK Cement' or equivalent, Quartz, Fine Silica Sand, Alkali Resistant Glass Fiber manufactured by 'N.E.G JAPAN or equivalent, Super Plasticizers manufactured by \\"BASF or equivalent Polymers manufactured by 'BASF or equivalent and UV resistant Synthetic inorganic pigments should be used for pigmentation manufactured by 'BAYFERROX (Germany) or equivalent. The material casting should take place in FRP Molds. The fixing of Screens should be 'Dry fixing' Le to be done with M.S Galvanized Clamps, fixtures and fasteners of Hilti / Fischer. 0.0 0.0 0.0 0.0 0.0 Ground Floor 0.0 Kg 8711.3 0.0 0.0 0.0 0.0 First Floor 0.0 Kg 8711.3 0.0 0.0 0.0 0.0 Second Floor 0.0 Kg 8711.3 0.0 0.0 0.0 0.0 TERACE/TOILET WATERPROOFING WORK 0.0 0.0 0.0 0.0 0.0 modified cementitious waterproofing coating over roof slab/Toilet after carrying out pond test on roof slab/Toilet, filling all defects, saturating the surface, mixing the products and then application in 2.0 mm thickness (1.8 Kg / sqm coverage rate for 1.0 mm thickness) in suitable layers complete in all respect, all materials, tools, plant & labour complete in all respect. Density 1850kg/m³ , Mix ratio (Powder to liquid) 3:1 by weight ,Water penetration Din 1048 1.5 Bar no leakage Potlife @ 25°C 2 hours & @ 40°C 30 minutes,Recoatable: 8-12 hours Elongation >42% (air) & >31% (under water),Tensile strength >20 kg/cm2 ,VOC content (HK prod code P10-17) 0.5 g/L including cost of all materials, conveyance, taxes and sundries,T&P, watering and curing by ponding water over terrace slab etc. complete as per the direction of the Engineer-in-charge. 0.0 0.0 0.0 0.0 0.0 Ground Floor 0.0 Sqm 543.6 0.0 0.0 0.0 0.0 Terrace 0.0 Sqm 543.6 0.0 0.0 0.0 0.0 Second Floor 0.0 Sqm 543.6 0.0 0.0 0.0 0.0 Third Floor 0.0 Sqm 543.6 0.0 0.0 0.0 0.0 Fourth Floor 0.0 Sqm 543.6 0.0 0.0 0.0 0.0 Fifth Floor 0.0 Sqm 543.6 0.0 0.0 0.0 0.0 SiXth Floor 0.0 Sqm 543.6 0.0 0.0 0.0 0.0 Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. 0.0 0.0 0.0 0.0 0.0 Ground Floor 0.0 Sqm 96.1 0.0 0.0 0.0 0.0 Supplying and fixing of Colour coated galvalume metal sheets Zinc aluminum alloy coated, Not less than 150 gms/sq.m, having high tensile steel sheet (Fy 550 Mpa) of 0.5 mm minimum thickness (BMT). The outside face (exposed face) shall be permanently color coated with PVF-2 paint of minimum DFT 20 microns over primer and inner side (internal face) shall be coated with same paint of minimum DFT 12 microns ,Colour Coated Flashing & Ridge board with all fasteners and fixtures, scaffolding etc. complete at all heights as per drawings and specification including preparation of bill of materials & shop drawings. (Galvalume Sheets shall be of any reputed make including Kingspan Jindal/'Tata Blue Scope Steel Limited', 'Laj Color Leaf (P) Limited' Loyd Insulations etc.) 0.0 0.0 0.0 0.0 0.0 Ground Floor 0.0 Sqm 1231.2 0.0 0.0 0.0 0.0 Micro Concreting1. Surface PreparationRemoving all loose and unsound concrete from the damaged area by mechanical means/manual chipping without damaging the parent concrete.Cleaning of reinforcement with rust remover to remove all loose rust and scale.2. Steel ProtectionApplication of zinc-rich primer over cleaned reinforcement steel to prevent further corrosion.3. Bonding CoatApplication of bond coat consisting of cement slurry mixed with SBR Latex (Dr. Fixit Pidicrete URP or equivalent) over the prepared surface to ensure proper bonding between old and new concrete.4. Repair Mortar / Micro ConcreteFilling of repaired pockets with Polymer Modified Mortar (PMM) for small thickness repairs.For larger sections, use Dr. Fixit Micro Concrete to restore the structural profile.5. Waterproofing TestAfter repairs, carry out ponding test on the opposite surface of the roof slab to check for any leakage/seepage.6. Injection GroutingIn case of observed seepage/leakage, carry out pressure injection grouting with suitable grout material (epoxy as specified) to arrest water ingressComplete as per the direction of the Engineer-in-Charge. (Note- Sample of materials shall be approved before procurement and use.) 0.0 0.0 0.0 0.0 0.0 Ground Floor 0.0 Sqm 3891.0 0.0 0.0 0.0 0.0 Groove cut the existing crack on concrete/masonry surface and remove all dust and loose particles, fill the cracks with Renderoc FC and inject the cracks by pressure grouting using Conbextra Cable Grout using PVC nozzles at speed less than 1 kg/cm2, Cut slits of 3 to 5mm width on the joints of crack line to depth of 15mm and 155mm on either side of crack, fill the groove with Renderoc SP40 and insert Nitoplate Crackfix plate having tensile strength >1000 MPA, fiber content 50 - 60% into the filled groove. Item rate is inclusive of materials all labour, tools and tackles, and transportation etc. complete as per specification and as directed by Engg.-in-charge. Payment shall be made as per actual site measurement.(Note- Sample of materials shall be approved before procurement and use.) 0.0 0.0 0.0 0.0 0.0 all Floor 0.0 Rmt 731.7 0.0 0.0 0.0 0.0 Providing and fixing GI chicken wire mesh 24 gauge and 12 mm mesh and required wideth for construction joints and chasing in brick work for electrical conduits or water supply pipes including cement slurry and pegs/nails with nailing machine as required before pastering etc. complete as directed by the Engineer-in-charge.(Note- Sample of materials shall be approved before procurement and use.) 0.0 0.0 0.0 0.0 0.0 all Floor 0.0 Rmt 186.0 0.0 0.0 0.0 0.0 Chequred Tiles 300mmx300mm of approved make, quality and colour without any warpage laid over an under layer of 20 mm thick base of cement mortar (1:4) (1 cement: 4 coarse sand) including cutting to size, laying and filling the joints with white cement slurry mixed with colouring pigment to match the shade and colour, cleaning the surfaces with oxlaic acid, machine grinding, mirror polishing including the cost of all materials, cost of all labour, conveyance, royalties, loading, unloading, sundries, watering and curing, T&P, etc. complete as per the direction of the Engineer-in-Charge.(Note- Sample of tiles shall be approved before procurement and use.) 0.0 0.0 0.0 0.0 0.0 Ground Floor 0.0 Rmt 656.0 0.0 0.0 0.0 0.0 Vetrified industrial floor Tile of premium grade having thickness 15mm to 16mm confirming to IS 4457 of size 600mmx600mm of approved make, quality and colour without any warpage laid over an under layer of 20 mm thick base of cement mortar (1:4) (1 cement: 4 coarse sand) including cutting to size, laying and filling the joints with white cement slurry mixed with colouring pigment to match the shade and colour, cleaning the surfaces with oxlaic acid, machine grinding, mirror polishing including the cost of all materials, cost of all labour, conveyance, royalties, loading, unloading, sundries, watering and curing, T&P, etc. complete as per the direction of the Engineer-in-Charge.(Note- Sample of tiles shall be approved before procurement and use.) (Make:Somany/Jhonson/RAK/kajaria) 0.0 0.0 0.0 0.0 0.0 Ground Floor 0.0 Sqm 2001.0 0.0 0.0 0.0 0.0 Finishing with Epoxy paint (Two or more coats) on steel work at all locations prepared and applied as per manufacturer's ecifications including appropriate priming coat (Red Oxide Zinc Chromate) , preparation of surface, etc. complete as per Direction of E.I.C. 0.0 0.0 0.0 0.0 Ground Floor 0.0 Sqm 272.4 0.0 0.0 0.0 0.0 Pressed Steel Doors With Vision PanelSupply installation of pressed steel doors of the specified dimensions and accessories such as hinges,door,stopper,tower bolt,door handle,door closer,dead lock,consedaled flush bolt,shaft lock,martise lock and vision panel etc.complete as mentioned along with warranty coverrage and after sales service etc.inclusive of all costs,delivery charge,fixing,fitting and any other invidental charges etc.complete excluding GST1. Hinges 2. Tower bolt 3. Door Stopper 4. Mortise Lock 5. Buffer (Make: Tata pravesh,Shaktihormann ETC) 0.0 0.0 0.0 0.0 0.0 Ground Floor 0.0 0.0 0.0 0.0 0.0 General Steeldoor Set 1000X2100 mm Single leaf door with vision panel 0.0 Each 22968.7 0.0 0.0 0.0 0.0 General Steeldoor Set 2,000.00X2,400.00 mm Double leaf door with vision panel 0.0 Each 41558.5 0.0 0.0 0.0 0.0 0.0 0.0 0.0 Providing gola 75x75 mm in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 stone aggregate 10 mm and down gauge), including finishing with cement mortar 1:3 (1 cement : 3 fine sand) as per standard design. 0.0 Rmt 258.60169491525426 0.0 0.0 0.0 0.0 Supplying and fitting-fixing of Un-plasticised Poly Vinyl Chloride (UPVC) Fixed window of approved make with 6mm thick glass of approved quality complete with frame, and all fitting and fixtures etc. complete in all respect as per the direction of the Engineer-in-Charge. 0.0 Sqm 5320.0 0.0 0.0 0.0 0.0 Supplying and fitting-fixing of Un-plasticised Poly Vinyl Chloride (UPVC) Fixed Partition of approved make with 6mm thick glass of approved quality complete with frame, and all fitting and fixtures etc. complete in all respect as per the direction of the Engineer-in-Charge. 0.0 Sqm 8620.0 0.0 0.0 0.0 0.0 Supplying, fitting and fixing of 5.5mm thick hexagonal Aluminium jally in windows as single groove, double groove and tapered clip as horizontal and vertical members for fixing of aluminium jally and joiting angle confirming to standrad Aluminium sections etc. complete as directed by the Engineer-in-charge. 0.0 Sqm 1841.0 0.0 0.0 0.0 0.0 Supplying and fixing of Hospital Glow Letter Type Name Board (Acrylic) including cost of designing, material, machine cutting & labour for mounting complete in all respect as directed by the Engineer-in-Charge.(Rate Per Letter) 0.0 Nos 3750.0 0.0 0.0 0.0 0.0 |
| 256 | Providing and fixing machine moulded aluminium covering of approved pattern & design,made out of machine cut aluminium sheet and machine holed for receiving dash fastener,over expansion joints on vertical surfaces/ceiling floors, the fixing on plate in one row on one side of joint only shall be done with stainless steel dash fasteners of 8 mm dia and 75 mm long bolt including providing aluminium washers 2 mm thick & 15 mm dia , at a staggered pitch of 200mm centre to centre including drilling holes in the receiving surface and providing expandable plastic sleeves in holes etc. complete as per direction of Engineer-in-charge. DAR-AW-Item No. 21.7-2023 Anodised aluminium sheet 2.5mm thick (anodised transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC 15) DAR-AW-Item No. 21.7.1-2023 G.R.C. JALI -Providing and fixing Glass Reinforced Concrete (GR.C) Screens in approved size pattern, design, shadeand thickness of 50mm on frame and design element in 30mm thick have weight approximately between 3.5 4 Kg per Sq Ft and color of M/S UniStone make or equivalent. The above weight and thickness is considering dimensions of screens up to 2133mm in height and 1219mm in width and having at least 50% void space. The screens should be made from '53 grade' White Portland Cement manufactured by JK Cement' or equivalent, Quartz, Fine Silica Sand, Alkali Resistant Glass Fiber manufactured by 'N.E.G JAPAN or equivalent, Super Plasticizers manufactured by \\"BASF or equivalent Polymers manufactured by 'BASF or equivalent and UV resistant Synthetic inorganic pigments should be used for pigmentation manufactured by 'BAYFERROX (Germany) or equivalent. The material casting should take place in FRP Molds. The fixing of Screens should be 'Dry fixing' Le to be done with M.S Galvanized Clamps, fixtures and fasteners of Hilti / Fischer. complete in all respect as per specification & direction of the Engineer-in-Charge. 0.0 Sqm 5928.7 0.0 0.0 0.0 0.0 Gypsum Board False Ceiling - Providing fitting and fixing of gypsum board false ceilling with aluminium anodised T Section No. 3215 with 2'-0\\" center to center, L section No. 1705 upto 15 micron on 4 walls to be fixed by means of steel screw and P.V.C plug and the Aluminium grid 2'-0\\"x2'-0\\" suspended from ceiling etc complete in all respect as per specification & direction of the Engineer-in-Charge. 0.0 Sqm 3017.1 0.0 0.0 0.0 0.0 Providing and fixing false ceiling with Trio/Hexa/Quadra UPVC Soffit Panels of approved make, shade, and finish, manufactured from high-quality virgin uPVC, suitable for interior use and resistant to moisture, termites, rot, and corrosion, including all materials and labour. The panels shall be fixed on a G.I. framework comprising galvanized iron channels, runners, supports, clamps, screws, anchors, and fasteners of adequate gauge, properly aligned, leveled, and securely fixed to the wall/structure. The work shall include supply of panels, G.I. components, trims, corner and edge profiles, joint covers, sealants, cutting, fixing, finishing, scaffolding, tools, and workmanship, ensuring neat joints and a uniform finish, complete in all respects as per manufacturer’s specifications and directions of the Engineer-in-Charge. 0.0 Sqm 4778.3 0.0 0.0 0.0 0.0 Providing and fixing wall panelling using Quadra /Hexa uPVC soffit panels of approved make, shade, and finish, manufactured from high-quality virgin uPVC, suitable for interior use and resistant to moisture, termites, rot, and corrosion, including all materials and labour. The panels shall be fixed on a G.I. framework comprising galvanized iron channels, runners, supports, clamps, screws, anchors, and fasteners of adequate gauge, properly aligned, leveled, and securely fixed to the wall/structure. The work shall include supply of panels, G.I. components, trims, corner and edge profiles, joint covers, sealants, cutting, fixing, finishing, scaffolding, tools, and workmanship, ensuring neat joints and a uniform finish, complete in all respects as per manufacturer’s specifications and directions of the Engineer-in-Charge. 0.0 Sqm 4724.2 0.0 0.0 0.0 0.0 Supply and fixing WPC Louvre of 2440 x 190 x 24mm having 55% wood powder and 30% HDPE: density of 1.425gm/ cm3: tensile strength of 29Mpa: modulous elasticity of 3500 Mpa: coefficient of thermal expansion 6 x 10-5 1/K and having anti-termite properties to be fixed with 25mm x 50mm x 1mm aluminum hollow section on the back of the Louvre with a greed work of 400mm gapcenter to center with all Labor, material, wastage, etc – all complete at site and directions of the Engineer-in-Charge. 0.0 Sqm 7164.1 0.0 0.0 0.0 0.0 Supplying , fitting and fixing of grid mineral fibre ceiling board having size 600 mm x 600 mm x 16mm of approved design and quality complete with frame and all fitting and fixtures. 0.0 0.0 1604.0 0.0 0.0 0.0 0.0 Providing, fitting and fixing of Sikadur Combiflex SG 20P 200 and sealed by Sikadur 31C @ 1.4kg per meter over the expansion joints after cleaning the joints and applying of Sikadur 32 @ 200 gms per meter Epoxy bonding agent and levelled by Sikagrout 214 @ 8kg per meter and covered with 300mm wide 16 gauge Aluminium sheet complete including cost, conveyance, taxes of all materials, labour, transportation charges etc as per specification and direction of the Engineer-in-charge. 0.0 0.0 0.0 0.0 0.0 Providing & fixing G.C.I. Sheet in roof including fixing of ridges wind ties etc. complete but excluding cost of fitting including drilling holes in wind ties etc. complete as per the direction of the Engineer-in-Charge.(Note- Sample shall be approved before procurement and use.) 0.0 Sqm 641.5 0.0 0.0 0.0 0.0 BWP 710 Grade Plywood & Mica Work - Making and fixing plywood work as per drawing and specification (main Str./body 18-19mm, doors 12-15mm, back panel 6-9mm thickness) with mica finishing for cupboard/racks/shelves/wardrobe with all necessary accessories i.e. metal handles, hinges, clamps, locks and screws etc. of approved quality including cost of all materials, labour & T&P etc complete as per direction of the Engineer-in-charge. 0.0 Sqm 11110.7 0.0 0.0 0.0 0.0 Ply Board & Mica Work :- Ply work with mica Finishing including cost of all materials, labour & T&P etc complete as per direction of the Engineer-in-charge. 0.0 Sqm 5456.0 0.0 0.0 0.0 0.0 Providing and applying two coats Unitile’s ‘Rodeo’ make or ‘Asian Paints’ in approved shade on a smooth cement sand plaster. The composition of the texture paint should consist of Acrylic Copolymer Resigns combined with Quartz, Silica, mineral aggregates, synthetic inorganic pigments, bactericide, fungicides and various other additives, giving the product water repellent properties. The first coat to be applied by brush or wool roller as a base coat, diluted with sufficient water and the final coat (Undiluted) to be applied by trowel and finished with acrylic trowel to obtain specified grooves. The thickness of both coats should be 1.0 to 1.5mm. The water repellence of the product is 86 gm/m2 as per test method IS: 5410 ‐1969. required for the work all complete as per direction of Engineer-in-charge. 0.0 Sqm 1159.2 0.0 0.0 0.0 0.0 Providing and executing mural painting work on the specified wall surface using high-quality, weather-resistant acrylic/emulsion paints of approved make and shade, including surface preparation by cleaning, scraping, minor crack filling, smoothing, and application of primer as required. The mural artwork shall be concept-based, aesthetically appealing, and executed by skilled artists as per approved design, theme, color scheme, and drawings, ensuring uniform finish, sharp detailing, and long-lasting color fastness. The work shall include all materials, labour, scaffolding, tools, protection of surrounding areas, and finishing complete in all respects as directed by the Engineer-in-Charge. 0.0 Sqm 1568.0 0.0 0.0 0.0 0.0 Heavy Duty Rope Clothesline Ideal for Drying Heavy Clothes 4 mm Thickness Nylon ClotheslineWhite. 0.0 Sqm 29.0 0.0 0.0 0.0 0.0 Supplying and fixing of Hospital Glow Letter Type Name Board (Acrylic) mentioning \\"VASTALYA SADAN \\" size as per specification including cost of designing, material, machine cutting & labour for mounting complete in all respect as directed by the Engineer-in-Charge. 0.0 Job 70000.0 0.0 0.0 0.0 0.0 Supplying and fixing of Hospital Glow Letter Type Name Board (Acrylic) mentioning \\"REGISTRATION COUNTER\\" size as per specification including cost of designing, material, machine cutting & labour for mounting complete in all respect as directed by the Engineer-in-Charge. 0.0 Job 75000.0 0.0 0.0 0.0 0.0 Supplying and fixing Rain Water Harvesting System including gutters, pipes, filters, and storage tanks, machinaries, as well as installation charges etc complete as directed by the Engineer-in-charge. 0.0 Job 50000.0 0.0 0.0 0.0 0.0 Supplying Master Layout Map in vinyl printing cum pasting colored pictures, text and symbols including fixing, installing and transportation complete as per the direction of the Engineer-in-charge. 0.0 Sqm 1650.0 0.0 0.0 0.0 0.0 Providing and supplying aluminium extruded tubular and other aluminium sections as per the architectural drawings and approved shop drawings , the aluminium quality as per grade 6063 T5 or T6 as per BS 1474,including super durable powder coating of 60-80 microns conforming to AAMA 2604 of required colour and shade as approved by the Engineer-in-Charge. (The item includes cost of material such as cleats, sleeves, screws etc. necessary for fabrication of extruded aluminium frame work. Nothing extra shall be paid on this account). 0.0 Kg 338.25 0.0 0.0 0.0 0.0 Designing, fabricating, testing, protection, installing and fixing in position semi (grid) unitized system of structural glazing (with open joints) for linear as well as curvilinear portions of the building for all heights and all levels, including:(a) Structural analysis & design and preparation of shop drawings for the specified design loads conforming to IS 875 part III (the system must passed the proof test at 1.5 times design wind pressure without any failure), including functional design of the aluminum sections for fixing glazing panels of various thicknesses, aluminium cleats, sleeves and splice plates etc. gaskets, screws, toggles, nuts, bolts, clamps etc., structural and weather silicone sealants, flashings, fire stop (barrier)-cum-smoke seals, microwave cured EPDM gaskets for water tightness, pressure equalisation & drainage and protection against fire hazard including:(b) Fabricating and supplying serrated M.S. hot dip galvanised / Aluminium alloy of 6005 T5 brackets of required sizes, sections and profiles etc. to accommodate 3 Dimentional movement for achieving perfect verticality and fixing structural glazing system rigidly to the RCC/ masonry/structural steel framework of building structure using stainless steel anchor fasteners/ bolts, nylon seperator to prevent bimetallic contacts with nuts and washers etc. of stainless steel grade 316, of the required capacity and in required numbers.(c) Providing and filling, two part pump filled, structural silicone sealant and one part weather silicone sealant compatible with the structural silicone sealant of required bite size in a clean and controlled factory / work shop environment, including double sided spacer tape, setting blocks and backer rod, all of approved grade, brand and manufacture, as per the approved sealant design, within and all around the perimeter for holding glass.(d) Providing and fixing in position flashings of solid aluminium sheet 1 mm thick and of sizes, shapes and profiles, as required as per the site conditions, to seal the gap between the building structure and all its interfaces with curtain glazing to make it watertight. 0.0 Sqm 2866.1 0.0 0.0 0.0 0.0 Extra for openable side / top hung vision glass panels (IGUs) including providing and supplying at site all accessories and hardwares for the openable panels as specified and of the approved make such as heavy duty stainless steel friction hinges, min 4 -point cremone locking sets with stainless steel plates, handles, buffers etc. including necessary stainless steel screws/ fasteners, nuts, bolts, washers etc. all complete as per the Architectural drawings, as per the approved shop drawings, as specified and as directed by the Engineer- in-Charge. 0.0 Sqm 2997.6 0.0 0.0 0.0 0.0 Providing, assembling and supplying vision glass panels (IGUs) comprising of hermetically-sealed 6-12- 6 mm insulated glass (double glazed) vision panel units of size and shape as required and specified, comprising of an outer heat strengthened float glass 6mm thick hard coated low emmissivity glass, of approved colour and shade with reflective soft coating on surface # 2 of approved colour and shade, an inner Heat strengthned clear float glass 6mm thick, spacer tube 12mm wide, dessicants, including primary seal and secondary seal (structural silicone sealant) etc.all complete for the required performances, as per the Architectural drawings, as per the approved shop drawings, as specified and as directed by the Engineer-in-Charge. The IGUs shall be assembled in the factory/ workshop of the glass processor.“(Payment for fixing of IGU Panels in the curtain glazing is included in cost of item No.26.2)“For payment, only the actual area of glass on face # 1 of the glass panels (excluding the areas of the grooves and weather silicone sealant) provided and fixed in position, shall be measured in sqm.“ (i) Coloured tinted float glass 6mm thick substrate with reflective soft coating on face # 2, + 12mm Airgap + 6mm Heat Strengthened clear Glass of approved make having properties as visible Light transmittance (VLT) of 25 to 35 %, Lightreflection internal 10 to 15%, light reflection external 10 to 20 %, shading coefficient (0.25- 0.28) and U value of 3.0 to 3.3 W/m2 degree K etc. The properties of performance glass shall be decided by technical sanctioning authority as per the site requirement. 0.0 Sqm 3036.1 0.0 0.0 0.0 0.0 Providing and fixing ISI Marked insulated fire rated door confirming to IS 3614: 2021, & tested to IS17518, and shall carry a unique label with certification/test report number. The fire rating shall be for 120minutes integrity and 30minutes insulation. Material shall be galvanised steel conforming to IS 277, made out of minimum 1.2 (18 SWG) for both frame and shutter, G.I. sheet (zinc coating 120 gsm). Frame shall be 125 x 75 grooved step profile with built in rebate for fire rated smoke seal. Frame shall be mitered and field assembled. EPDM smoke seal to be provided along with frame as standard. Door shutter shall be double skin of 60mm thick step with required fire rating and insulation with vision panel. The infill material shall be high density mineral wool of minimum 120kg/sq.m3. Intumescent seal shall be provided on all around the door leaf of minimum size 15 x 1.5mm thick. All doorset shall be factory prepped for receiving appropriate hardware and provided with necessary reinforcement for hinges, locks and door closers. The door stiles should be interlocked, for pairs of doors integral astragals has to be provided on the meeting stile for both active and inactive leaf. Vision lite, minimum 5mm clear fire rated glass of size 200 x 300mm (max 0.06sq.mt) on shutter, fixing with clipon arrangement. All frame and door shutter shall be finished polyster powder coated to minimum 50microns, of approved colour as per the direction of the engineer incharge. Cost of doorset shall include following hardware and accessories as a complete assembly. SS ball bearing hinges of SS304 grade of size 100x75x3mm, 1 set Panic device for double leaf doorset and external trim with key cylinder tested as per EN1125 and CE marked. 1no Door closer per leaf with spring size of EN 3-5, as per EN1154 & CE marked,1no door door coordinator also be given in case of double leaf door. Suitable anchor fastners for fixing on different type of wall construction as per manufacturer recommendation.Once frames is installed it shall be filled with fire rated PUF. Manufacturer test certificates shall covers complete door set as a latched assembly with a valid test certificate not exceeding 5 years from the date of issue of report. for more info refer doors details drawing. Approved make : Shakti Hormann, MPP, Godrej, Promat 0.0 Sqm 23880.0 0.0 0.0 0.0 0.0 Providing and fixing of Standard Duty Hollow Metal Door Frame and Flush Door Shutter of approved make such as Shakti Hormann, conforming to IS 4351 for steel door frames and IS 2191 (Part-II) for shutters, manufactured in an ISO 9001:2015 certified facility. The door frame shall be single rebate grooved profile of size 125 x 55 mm fabricated from 1.2 mm (18 gauge) thick galvanized steel sheet confirming to IS 277, suitable for 40 mm thick shutter, with mitered corners, self-tab assembly, inbuilt groove for PVC sealing system, mortised, drilled and tapped for hardware, complete with back plate brackets, anchor fasteners for fixing in finished plastered masonry openings, filled with non-fire rated PUF and gaps sealed with silicone sealant. The door shutter shall be 40 mm thick fully flush type with tubular core chipboard infill, faced on both sides with minimum 3 mm thick calibrated pre-laminated fibre board of minimum density 850 kg/m³ in approved shade, with minimum 40 mm wide LVL rails and stiles, all edges finished with 0.8 mm thick PVC edge banding using PUR hot melt adhesive, factory pre-engineered for hardware fixing, complete with all materials, labour, transportation, fitting and fixing in position including PVC seal, approved hardware provisions and finishing in GRAINTEK texture/wood stain/powder coated finish as specified, complete in all respects as per direction of Engineer-in-Charge. 0.0 Sqm 9285.0 0.0 0.0 0.0 0.0 Providing and fixing of Sliding windows of approved make to be fabricated from roll formed sections made of pre-painted steel (base steel as per IS-513 of 0.6 mm thick \\"D\\" quality, galvanized as per IS-277 with zinc of 120 Gm/Sq.mtr) with total coated thi 0.0 0.0 0.0 0.0 0.0 0.0 Ground Floor 0.0 Sqm 6486.1 0.0 0.0 0.0 0.0 First Floor 0.0 Sqm 9810.7 0.0 0.0 0.0 0.0 Second Floor 0.0 Sqm 9810.7 0.0 0.0 0.0 0.0 Third Floor 0.0 Sqm 9810.7 0.0 0.0 0.0 0.0 Fourth Floor 0.0 Sqm 9810.7 0.0 0.0 0.0 0.0 Fifth Floor 0.0 Sqm 9810.7 0.0 0.0 0.0 0.0 SiXth Floor 0.0 Sqm 9810.7 0.0 0.0 0.0 0.0 Add for plaster drip course/ groove in plastered surface or moulding to R.C.C. projections. 0.0 0.0 0.0 0.0 0.0 Ground Floor 0.0 Rmt 43.8 0.0 0.0 0.0 0.0 First Floor 0.0 Rmt 43.8 0.0 0.0 0.0 0.0 Second Floor 0.0 Rmt 43.8 0.0 0.0 0.0 0.0 Third Floor 0.0 Rmt 43.8 0.0 0.0 0.0 0.0 Fourth Floor 0.0 Rmt 43.8 0.0 0.0 0.0 0.0 Fifth Floor 0.0 Rmt 43.8 0.0 0.0 0.0 0.0 SiXth Floor 0.0 Rmt 43.8 0.0 0.0 0.0 0.0 |
| 257 | Providing and fixing barbed wire fencing on R.C.C. (1:2:4) fencing posts with chips 1.68M long, 13cm x 13cm at bottom and 8cm x 8cm at top and 30cm 30cm x 8 cm at base finished smooth at spacing of 2.0m c/c , fixing with G.I. barbed wire both in horizontal and in diagonal by means of staples and staining hooks and tying with G.I wire including cost of barbed wire, staples, hooks, tying wires and labour, post etc complete in all respect as per the direction of the Engineer-in-charge. |
| 258 | Supplying and fixing of Elastomeric Membrane of 200mm x 2mm size for expansion joint sealing from approved manuefacturer, fixing with epoxy adhesive of approved quality complete. |
| 259 | Supplying and fitting -fixing of Un-plasticised poly Vinyl Chloride (UPVC) (FENESTA/NCL VECCA LTD) Ventillator/Top Hung-60 Series duly manufactured using UPVC reinforced Profiles of 60mmx 55mmx2.5mm for outer frames ,75mmx60mmx2.25mm for casement window sash profile capable of mounting single glazing system,structurally reinforced with hot dip galvanised upto 50 microns of minimum thickness of 1.5 mm prefabricted and welded through fusion welding the wwindow sash shall be fitted with 6mm thick clear toughened glass of Saint-Gobain make duly fixed with EPDM weathering seal resistant accessories like clipping locking system made of aluminium 1 no per set of sashes and the system to be installed at the site using anchor fasteners,silicon rubber sealant,easy glazing/deglazing at siteetc including cost and conveyance of all accessories labour charges,materials and product confirming to ASTM D 638-14,EN-477-95 and other applicable codes and standards. Providing and fixing of 12mm thick Clear Toughened Glass Frameless Door WithDorma Premium Fittings.Dorma Premium (9111198) Unilite Package BTS 75,UL PT 10with Cover,UL PT 20 with Cover, UL US 10 Luck with Cover and PT 24,Dorma Premium(9137121) H Type Handle 450mm,12mm Clear Toughened Glass with Cutout and Hole.including the cost of all materials, hardware fittings, cost of all labour, conveyance,loading, unioading, T&P, etc, complete as per the direction of Engineer-in-Charge. 0.0 0.0 Earth Filling foundation and plinth-construction of embankment with earth approved material obtained from borrowpits, transporting to site, spreading, grading to required slope and compacting to meet requirement of table 300-2. 0.0 0.0 Cum 203.9 0.0 TOTAL SUPER STRUCTURE 30050834.212644555 Total civil Works 42940161.45803206 956621.4584999998 3191906.4640999995 37954832.658532046 B SOLAR Solar System 42295872.944132045 Supply Installation Testing and Commissioning of on grid Solar Photovoltaic Power Plant conforming to MNRE specifications as amended, consisting of Mono / Poly Crystalline silicon solar cells, net metering facility ,necessary protections, earthing, mounted on Aluminium / GI structure of suitable strength with following components a complete aas arequired: a) Solar Photovoltaic Module of capacity 330Wp or above, manufactured in India, conforming to IS14286 / IEC61215, IS/IEC61730-Part-1,IS/IEC61730-Part-2. Solar Photovoltaic Module conversion efficiency shall not be less than 16.5%. PV modules used in solar power plants /systems must be warranted for their output peak watt capacity, which should not be less than 90% at the end of 10 years and 80% at the end of 25 years. b) Power Conditioning Unit (PCU) of 350-800 V DC Input voltage range and 400 V AC, three phase , 4 wire, 50Hz +/- 2.5Hz, output voltage suitable to generate AC Power with efficiency not less than 97%, total harmonic distortion less than 3% and suitable for ambient temperature from 0 to 50 degree Celcious. The PCU shall adjust the voltage and frequency level to suit the Grid Voltage,frequency. c) Data Monitoring System complete with accessories.d)Fixing of Array junction box & Main junction box with IP 65 protection and termination arrangement for incoming and outgoing cable along with glands, lugsand other accessories etc. asarequired.e) Lightning and surge voltage protection. f) Connections & Interconnections by supplying & fixing required size XLPE insulated copper conductor 1.1 kV grade armoured power and control cables between solar modules, main power cable to grid supply PCU unit along with supplying & fixing of necessary channel/ conduit lugs and other accessories etc. asrequired. with all required accessories as required as per the direction of Engg-in-charge.Make-Kamal Solar/ EMMVEE/ Venus / Anchor/panasonic or equievalant reputed make & model A catogory, ISI marked as approved . The entire SOLAR system should be Replacement Warranty will be 5 years 5.0 kw 60500.0 302500.0 C FIRE FIGHTING A FIRE EXTINGUISHERS |
| 260 | Providing and Fixing ISI marked ABC stored pressure type Fire extinguisher of 6 Kgs. Capacity confirming to IS: 15683 with discharge hose, nozzle, Mono Amonium Phosphate base & ABC powder pressurised with nitrogen gas carrying handle and wall mounting bracket etc as required with 5 Years maintenace. SAFEGUARD , INTIME , FIRESHIELD 0.0 |
| 261 | Providing and Fixing of 4.5 Kgs. Capacity CO2 gas type ISI marked fire extinguisher (IS: 15683) fitted with high pressure 1 mtr. Long discharge hose & horn complete with refill gas, carrying handle and wall mounting bracket etc as required with 5 Years maintenace. |
| 262 | Providing and Fixing of of 2 kG capacity Eco Friendly, Stored pressure type filled with HFC 134 A ( clean agent fire extinguishant having Zero Ozone depletion potential ) Clean Agent Fire Extinguishers with safety seal, pressure guage, controllable discharge mechanism, helium leak detection tested and conforming to IS 15683 complete with initial charge as required with 5 Years maintenace. |
| 263 | Fire buckets 3 nos round bottom type enamel painted, white inside & Red out side and Letter \\"FIRE\\" in black out side and handle with mounting bracket and Fire bucket stand fabricated by MS angles with 5 Years maintenace.Make:FABRICATED TOTAL FOR PART- A 0.0 B SIGNAGES 0.0 |
| 264 | Floor identification signage (i.e, GROUND FLOOR… ETC.,) at each stair enclosure on every floor, indicating the floor number in words, lettering size shall be 7.5cm with contrasting colour from back ground. Size shall be 15cm * 60cm. |
| 265 | Fire Exit signage at each stair on every floor, indicating the direction of fire exit, lettering size shall be 7.5 cm with contrasting color from back ground. Size shall be 15cm x 60cm. Total Fire- 104195.0 D LANDSCAPING AND HORTICULTURE (a) Grass |
| 266 | Providing and fixing Neelgiri/Mexican grass turf with earthy 50mm to 60mm thickness of existing ground prepared with proper level and ramming with required tools wooden (Dhurmos) and than rolling the surface with light roller make the surface smoothen and light, watering with sprinkler and maintenance for 30 days or more till the grass establish properly as per direction of officer incharge. B. SITE PREPARATION 0.0 |
| 267 | Supplying and stacking of good earth at site including royalty and carriage upto 5 km complete (earth measured in stacks will be reduced by 20% for payment). |
| 268 | Supplying and stacking sludge at site including royalty and carriage upto 5 km complete (sludge measured in stacks will be reduced by 8% for payment). |
| 269 | Supplying and stacking at site dump manure from approved source, including carriage upto 5 km complete (manure measured in stacks will be reduced by 8% for payment) . Screened through sieve of I.S. designation 20 mm 8.333333333333332 Cum 239.6 1996.6666666666663 Screened through sieve of I.S. designation 16 mm 8.333333333333332 Cum 267.0 2224.9999999999995 Screened through sieve of I.S. designation 4.75 mm 8.333333333333332 Cum 288.9 2407.4999999999995 |
| 270 | Spreading of sludge, dump manure and/or good earth in required thickness as per direction of officer-in-charge (cost of sludge, dump manure and/ or good earth to be paid separately). |
| 271 | Mixing earth and sludge or manure in the required proportion specified or directed by the Officer-in-charge. PLANTATION 0.0 Supply & planting of the tree as per botanical name / common name & specification mentioned here under : 0.0 |
| 272 | Tree Providing and stacking of Tecoma argentea of height 120-135 cm. in big poly bag of size 25 cm as per direction of the officer-in-charge 10.0 Each 121.43100000000001 1214.3100000000002 Providing and stacking of Saraca indica (Sita Ashok) of height 105-120 cm. in big poly bags of size 25 cm as per direction of the officer-in-charge 10.0 Each 121.43100000000001 1214.3100000000002 Providing and stacking of Polyalthia pendula (Ashok Pendula) of height 180-195 cm. in gunny bag of size 30 cm as per direction of the officer-in-charge. 10.0 Each 151.793 1517.93 Providing and stacking of Plumeria alba dwarf dwarf of height 90-105 cm. with 3-4 branches and thick stem in big size HDPE bags as per direction of the officer-in-charge. 10.0 Each 1138.388 11383.88 Providing and stacking of Plumeria rubra of height 120-150 cm. with 3-4 branches and thick stem in big size HDPE bags as per direction of the officer-in-charge 10.0 Each 606.9 6069.0 Providing and stacking of Mimusops elengi (Maulsri) of height 180-195 cm., well developed with thick stem in big in big size HDPE bag as per direction of the officer-in-charge 10.0 Each 189.737 1897.37 Providing and stacking of Foxtail palm of ht. 240-270 cm bottom girth 35- 40 cm well developed in big size HDPE bags as per direction of the officer-in-charge. 10.0 Each 986.612 9866.119999999999 |
| 273 | Ground cover Providing and stacking of Duranta Golden, having ht.15 to 20 cm bushty shape with fresh and healthy leaves in 15 cm size of Earthen Pot/Plastic Pot & as per direction of the officer-in-charge 10.0 Each 30.362 303.62 Providing and stacking of Alternanthera species of height 15 cm to 20 cm, full of branches and foliage in 15 cm size of Earthen Pot/Plastic Pot & as per direction of the officer-in-charge. 10.0 Each 30.362 303.62 Providing and stacking of Daniella variegated, with 3 to 4 variegated leaves in 20 cm size of Earthen Pot/Plastic Pot & as per direction of the officer-in-charge 10.0 Each 30.362 303.62 Providing and stacking of Clerodendrum inerme having ht. 25 cm to 30 cm multi branched in 20 cm size of Earthen Pot/Plastic Pot & as per direction of the officer-in-charge 10.0 Each 15.181 151.81 |
| 274 | Shrurbs Providing and stacking of Ficus reginald well branched, bushy of height 60- 75 cm. in earthen pots of size 25 cm as per direction of the officer-in-charge. 8.0 Each 151.793 1214.344 Providing and stacking of Euphorbia caracasana (bronze colour leaves) of height 90-105 cm., bushy in big size HDPE bag as per direction of the officer-in-charge. 8.0 Each 159.375 1275.0 Providing and stacking of Chandni dwarf of height 15-20 cm., well branched in earthen pots of size 20 cm as per direction of the officer-in-charge. s per direction of the officer-in-charge. 8.0 Each 53.125 425.0 Providing and stacking of Thuja compacta of height 45-60 cm., well branched in earthen pots of size 25 cm as per direction of the officer-in-charge 8.0 Each 98.66799999999999 789.3439999999999 |
| 275 | Medicinal plant Providing and Stacking of Curry leaf of height 75-90 cm in poly bag of size 25 cm as perdirection of the officer-in-cha 10.0 Each 113.83199999999998 1138.3199999999997 Providing and Stacking of Adusha of ht. 30 cm with multi branches in Poly bag of size 20 cm. as per direction of the officer-in-charge. 10.0 Each 45.543 455.43 Providing and Stacking of Aprajita Blue well developed in poly bag of size 20 cm as per direction of the officer-in-charge 10.0 Each 45.543 455.43 Providing and Stacking of Peepli well developed in poly bag of size 20cm as per direction of the officer-in-charge. 10.0 Each 45.543 455.43 Providing and Stacking of Shivnath well developed in poly bag of size 20 cm as per direction of the officer-in-charge. 10.0 Each 60.707 607.07 Providing and Stacking of Marwa Dona of ht. 30cm with multi branches in Poly bag of size 20 cm.as per direction of the officer-in-charge 10.0 Each 45.543 455.43 Providing and Stacking of Nirgundi well developed in poly bag of size 20 cm as per direction of the officer-in-charge 10.0 Each 45.543 455.43 Providing and Stacking of Ficus panda plant of height 90 -105 cm. multibranches, well developed in poly bags of size 25 cm as per direction of the officer-in-charge. 10.0 Each 242.86200000000002 2428.6200000000003 Providing and stacking of Mimusops elengi (Maulsri) of height 180-195 cm., well developed with thick stem in big in big size HDPE bag as per direction of the officer-in-charge 10.0 Each 237.17125 2371.7124999999996 |
| 276 | Ornamental Providing and Displaying Travelers palm well developed with fresh & healthy foliage 120 to 150 cm ht. in 35 cm Cement Pot as per direction of the officer-in-charge. 5.0 Each 735.93 3679.6499999999996 Providing and Displaying Ficus reginold Topiary well developed with fresh & healthy 6 to 7 big ball specific size 210 to 240 cm ht in 45 cm Cement Pot as per direction of the officer-in-charge 5.0 Each 3102.5 15512.5 Providing and Displaying Mascarena palm well developed with fresh & healthy foliage leaves 150 to 180 cm ht in 35 cm Cement Pot as per direction of the officer-in-charge 5.0 Each 2800.4464285714284 14002.232142857141 Providing and Displaying Cycus cirsnallis well developed with fresh & healthy 35 to 40 lush green leaves in 40 cm Cement Pot as per direction of the officer-in-charge. 5.0 Each 2956.028 14780.14 Holes 90 cm dia, and 90 cm deep 70.0 Nos 119.6 8372.0 Holes 45 cm dia, and 45 cm deep 182.0 Nos 15.8 2875.6 Nilkamal Plastic Manual-Lift Wheel Garbage Dustbin (Green, Blue, 60 L) 4.0 Nos 1690.0 6760.0 Total Landscpe 431853.0558295238 ALL TOTAL- 43778709.51386158 Construction Of Godabarish Mishra Adarsh Prathamik Vidyalaya At Govt. UGHS Ichhapur, Jharigam Block, Ichhapur (GP) , Nabarangpur District (Phase-II) A. INTERNAL P.H. & SANITARY WORK Sl. No. Description of work Qnty. Unit Rate Amount Rs. |
| 277 | Providing and fixing Clorinated Polyvinyl Chloride [CPVC] pipes SDR-11 conforming to IS:15778, having thermal stablity for hot & cold water supply , including all CPVC plain & brass threaded fitting including fixing the pipe with clamps at 1.00m spacing . This includes jointing of pipes and fittings with one stp CPVC solvent cement and testing of joints complete as per specification and direction of Enfineer-in-charge. 20 mm PVC sch-80 pipes 70.0 Mtr 307.6 21532.0 25 mm PVC sch-80 pipes 70.0 Mtr 426.8 29876.0 32 mm PVC sch-80 pipes 100.0 Mtr 587.2 58720.00000000001 50 mm PVC sch-80 pipes 120.0 Mtr 1201.5 144180.0 |
| 278 | Supplying all materials,labour and T&P for cutting holes through existing brick work including making good to the same in cement mortar(1:4) for taking G.I. pipes and fittings /P.V.C. pipes and fittings all complete as per specification. 250mm Thick 38.0 Each 67.4 2561.2000000000003 |
| 279 | Supplying all materials,labour and T&P for cutting holes in R.C.C. floors and roofs up to 19 cm. thick including for passing GI / PVC pipes and fittings etc. and repairing the holes after insertion of pipes etc. with cement concrete 1:2:4 including finishing complete to make it leak proof leak to the damages all complete as per specification and direction of the Engineer-in-charge. 7.0 Each 219.1 1533.7 |
| 280 | Supplying all materials,labour and T&P for cutting groves in pucca floor and walls for taking G.I. pipes and fittings /P.V.C. pipes and fittings and making good to the damages all complete as per specification. 70.0 Mtr 278.1 19467.0 |
| 281 | Supplying all materials, labour T&P and fitting and fixing brass/CP fittings of the following nominal bore with supply of all joiniting materials complete as per specification and direction of the Engineer-in-charge. a) Supplying all labour and T&P for fixing 2 in 1 bib cock of the following size as per specification all complete. 16.0 Each 1308.3 20932.8 b) Supplying all labour and T&P for fixing long body bib cock of the following size as per specification all complete.15mm Dia 4.0 Each 1078.2 4312.8 c) Supplying all labour and T&P for fixing CP Angular stop cocks polished bright confirming to IS:781-1995 of the following nominal sizes as per specification all complete. 15mm Dia 28.0 Each 937.6 26252.8 d) Supplying fitting fixing of C.P Pillar Taps highpressure lettered Hot and cold with long screws shanks and back nuts of the following nominal bore as per specification. (Make-Somany/Cera/Hindware) 15mm Dia 17.0 Each 1475.0 25075.0 e) Supplying all labour and T&P for fixing CP short body Bib cock [taps] polished bright confirming to IS:781-1995 of the following nominal sizes as per specification all complete . 3.0 Each 915.5 2746.5 f) Supplying all labour and T&P for fixing U.P.V.C Ball valve [ horizontal plungr type] confirming to IS:1703-1977 of the following nominal sizes as per specification all complete. ) 25mm Dia 6.0 Each 687.1 4122.6 g) Supplying all labour and T&P for fixing U.P.V.C Ball valve [ horizontal plungr type] confirming to IS:1703-1977 of the following nominal sizes as per specification all complete. 32mm Dia 4.0 Each 1421.6 5686.4 h) Supplying all labour and T&P for fixing U.P.V.C Ball valve [ horizontal plungr type] confirming to IS:1703-1977 of the following nominal sizes as per specification all complete. 50mm Dia 2.0 Each 3125.1 6250.2 i) Providing and fixing C.P. Brass Extension Nipple 1 inch with extension piece as per direction of Engineer-in-charge. 15.0 Each 594.39 8915.85 j) Supplying fitting fixing of CP waste of the following noninal diameter for wash hand basin and sink as per specification. 14.0 Each 380.1 5321.400000000001 k) Supplying all materials,labour and T&P for fixing CP Gratings of the following nominal diameter of outlet, of self cleaning design with sand cast iron screwed down or hinged grating with or without vent arm including cutting and making good to the walls and floors etc. all complete as per specification. 38.0 Each 1190.4 45235.200000000004 |
| 282 | Supplying fitting fixing of C.P health facuet high pressure lettered Hot and cold with long screws shanks and back nuts of the following nominal bore as per specification. 15mm dia CP Health Faucet of 1mtr long PVC tube 8.0 Each 809.8 6478.4 |
| 283 | Providing and fixing of Rational moulded polyethylene cylendrical vertical water storate tanks confirming to IS:12701-1996 including cutting holes through the tank and fixing mild steel tubes and fittings and proviidng extra sockets and jam nuts , fixing ball volve ete. including hoisting up to a hite of 5.00metes above ground level and placing the tank to the required position etc. all complete as per specification and direction of the engineer-in-charge. i) Overhead water storage tanks 8000.0 Lit. 13.59424 108753.92 ii) Extra over item no.3.1.8 for hoisting Rational moulded polyethylene cylendrical vertical water storage tanks of following sizes for every additional height of 5.00m. Or part thereof complete as per specification and direction of the engineer-in-charge. Water storage tanks 4.0 Each 1248.0 4992.0 |
| 284 | Supplying all materials, labour, T&P and fitting and fixing U-PVC SWR soil waste ventilating pipes and fittings of the following outside diameter conforming to ISI No 13592/1992 to walls with nails, bobbins and wooden plugs or laying in trenches including jointing with supply of approved rubber lubricant by non-heat application method/as per manufacturer's specification, testing, earthwork in excavation in all kinds of soil and refilling of trenches as per specification and direction of the Engineer-In-Charge. 110mm diameter PVC SWR pipes 105.0 Mtr 391.3 41086.5 75mm diameter PVC SWR pipes 90.0 Mtr 242.9 21861.0 110mm PVC door Tee 12.0 Each 388.6 4663.200000000001 75mm PVC door Tee 5.0 Each 293.0 1465.0 110mm PVC offset 10.0 Each 138.0 1380.0 110mm PVC door bend 10.0 Each 216.4 2164.0 75mm PVC door bend 10.0 Each 114.1 1141.0 110mm PVC plain shoe bend 10.0 Each 170.8 1708.0 75mm PVC plain shoe bend 10.0 Each 83.2 832.0 110mm PVC vent cowl 10.0 Each 86.6 866.0 75mm PVC vent cowl 0.0 Each 73.0 0.0 110mm S-trap 12.0 Each 629.7 7556.400000000001 110mm P-trap 1.0 Each 348.2 348.2 110mm SWR Pipe Clip 105.0 Each 30.4 3192.0 75mm SWR Pipe Clip 90.0 Each 23.4 2106.0 110/75 mm Dia Reducer/Connector 5.0 Each 258.5 1292.5 90mm Nahani Trap 33.0 Each 145.6 4804.8 |
| 285 | Supplying all materials,labour and T&P for fixing of PVC 10 ltr capacity low level flushing cistern with manually controlled device[handle cover] confirming to IS 7231 with fittings and fixtures etc. all complete as per specification. 10 Liters capacity PVC cistern 16.0 Each 1954.3 31268.8 |
| 286 | Supplying all materials,labour and T&P for fixing water closet ,squatting pan(Indian type.W.C.pan or Orissa pan) confirming to IS 2556 : Part-3-2004 duly embedded in cement concrete (1:4:8) using 40mm.nominal size h.b.g. chips [including foot rest for I.W.C. and trap] all complete as per specificationand directon of theEngineer - in - charge. 8.0 Each 3837.7 30701.6 |
| 287 | Supplying all materials,labour and Supplying all materials,labour and T&P for fixing in cement mortar (1:3) a pair of white vitereous china (250x130x30mm.) foot rest for squatting water closet. etc. all complete as per specificationand direction of the Engineer-in-charge. 8.0 Pair 560.9 4487.2 |
| 288 | Supplying all materials,labour and T&P for Supplying all materials,labour and T&P for fixing wash down water closet (European type W.C.) with integral \\"S\\" or \\"P\\" trap tothe floor with wooden plug and chromium plated screw including jointing the trap with soil pipe in cement mortar (1:1) etc. all complete as per specification. 7.0 Each 3175.6 22229.2 |
| 289 | Supplying all materials,labour and T&P for fixing plastic seat and cover for wash down water closet with chromium plated brass hinges and rubber buffers all complete as per specification. 7.0 Each 923.4 6463.8 |
| 290 | Supplying all materials,labour and T&P for fixing wash hand basin (SS Made) with hole for pillar taps confirming to IS 2556:part4-2004 with cast iron /M.S. brackets painted white including cutting holes in walls and making good to the damages etc. all complete as per specification. 12.0 Each 4599.3 55191.600000000006 |
| 291 | Supplying all materials,labour and T&P for fixing corner wash hand basin with hole for pillar taps confirming to IS 2556:part4-2004 with cast iron /M.S. brackets painted white including cutting holes in walls and making good to the damages etc. all complete as per specification. 4.0 Each 2666.6 10666.4 |
| 292 | Supplying all materials,labour and T&P for fixing Pedestal for wash hand basin complete recessed at the back for the receiptionof pipe and fittings etc. all complete as per specification including cost of pedestal for wash basin 4.0 Each 2621.9 10487.6 |
| 293 | Supplying all materials,labour and T&P for fixing of 600x450 bevelled edge mirror of superior glass mounted on 6mm thick ac sheet or ply wood sheet and fixed to wooden plugs with chromium plated brass screws and washers etc. All complete as per specification . 600mmx450mm size B.E.mirror 12.0 Each 2167.7 26012.399999999998 |
| 294 | Supplying all materials,labour and T&P for fixing standard size glass self with chromium plated brass brackets fixed to wooden plugs with chromium plated brass screws and washers etc. all complete as per specification. 13.0 Each 801.7 10422.1 |
| 295 | Supplying all materials,labour and T&P for fixing standard size C. P. towel rail fixed with chromium plated brass brackets fixed to wooden plugs with cromium plated brass screws complete as per specification. 8.0 Each 1080.1 8640.8 |
| 296 | Supplying all materials,labour and T&P for fixing of cromium plated brass soap dish complete with chromium plated brass brackets fixed to wooden plugs with chromium plated brass screws as per specification. 16.0 Each 354.4 5670.4 |
| 297 | Supplying all materials,labour and T&P for fixing standard size C. P. towel ring fixed fixed to wooden plugs with cromium plated brass screws complete as per specification. |
| 298 | Supplying all materials,labour and T&P for fixing of liquid soap container - glass container or plastic container with chromium plated brass lid and brackets fixed to wooden plugs with chromium plated brass screws as per specification. |
| 299 | Supplying all materials,labour and T&P for fixing stainless steel AISI 304 [18/8] Kitchen sink as per IS 13983 with cast iron bracet and stainless steel plug including painting of fittings and brackets ,cutting and making good to the walls etc. all as per specification including cost of sink with all accessories. 2.0 Nos 6159.2 12318.4 |
| 300 | Supplying all labour and T&P for fixing CP Concealed stop cocks polished bright confirming to IS:781-1995 of the following nominal sizes as per specification all complete. |
| 301 | Supplying all materials,labour and T&P for fixing Porcelain Urinal respectively with waste pipe by means of white lead mixed with chopped hemp etc. all complete as per specification. |
| 302 | Fixing standard size Chromium Plated brass or glazed porcelain Toilet paper holder fixed to woden plugs with Chromium Plated brass screws complete as per specification and direction of the Engineer in charge. |
| 303 | Providing and fixing approved quality E.W.C. Matrix Set comprising European Water Closet (E.W.C.), low/high level cistern, wash basin and sanitary fittings such as bottle trap, pillar cock, toilet paper holder, towel rail, soap case, mirror, etc., including grab bar set for Accessible/Handicap Toilet consisting of stainless steel grab bars and support fittings required for differently-abled users, conforming to universal accessibility standards. The set shall include wall-mounted horizontal and vertical support bars near the W.C. and wash basin area, made of SS 304 grade stainless steel with satin/matt finish, complete with necessary brackets, anchor fasteners, screws, bends, end caps and all accessories. The arrangement shall ensure safe support and ease of movement for wheelchair users and physically challenged persons. The work shall include proper fixing, alignment, levelling and positioning as per approved drawings, CPWD/IS accessibility guidelines and directions of the Engineer-in-Charge, complete in all respects. EXTERNAL P.H. & SANITARY WORK ------------------ |
| 304 | Supplying all materials, labour, T & P and constructing Gully trap chamber of the following inside size with 8 cm thick R.C.C. precast cover slab in CC (1:2:4) mix using 12mm size h.g. chips, foundation concrete (1:4:8) using 40mm size h.g. metal on bed aound trap , Fly Ash brickwork in CM (1:6) in P&F and inside 12mm thick cement plastering (1:3) finished with a floating coat of neat cement including fixing 100mm x100mm size gully trap, 150mm x150mm C.I gratig etc. all complete as per aproved drawing, specification and direction of Engineer-in-charge. 250mmx250mm with RCC cover 9.0 Each 1713.1 15417.9 |
| 305 | Constructing inspection chamber with R.C.C top slab in (1:2:4) mix, foundation concrete (1:3:6), inside plaster 12mm thick with cement mortar (1:3) finished with neat cement punning, 12mm thick outside cement plaster (1:3), brick work with K.B bricks having crushing strength not less than 75kg/cm² with dimensional tolerance ± 8 percent in cement mortar (1:5), cement concrete (1:2:4) finished smooth using 12mm size h.g chips, earthwork in excavation in all kinds of soil and refilling the cavity around the chamber complete as per specification. Inspection Chamber inside size 750mm x 750mm and 450mm 8.0 Each 13424.8 107398.4 |
| 306 | Supplying all materials,labour and T&P for laying in trenches unplasticized PVC pipes and specials of the following outside dia. for all classes including jointing with approved solvent cement by non-heat application method including testing as per specification and direction of Engineer-in-charge etc. all complete. [including earth work and cost of pipes. a) 110 mm dia U-PVC pipes Class-3 61.0 mtr 993.1 60579.1 b) 160 mm dia U-PVC pipes Class-3 30.0 mtr 2132.1 63963.0 |
| 307 | Constructing manholes with R.C.C top slab in (1:2:4) mix, foundation concrete (1:3:6), inside plaster 12mm thick with cement mortar (1:3) finished with neat cement punning, 12mm thick outside cement plaster (1:3), brick work with K.B bricks having crushing strength not less than 75kg/cm² with dimensional tolerance ± 8 percent in cement mortar (1:5), cement concrete (1:2:4) finished smooth using 12mm size h.g chips, earthwork in excavation in all kinds of soil and refilling the cavity around the chamber complete as per specification. a) Plain Manholes inside size 900mm x 800mm and 450mm deep 8.0 each 17867.0 142936.0 |
| 308 | Construction of 50 Users Septic Tank (2 No.s) a)-i Earth work in excavation in foundation trenches, column foundation, pit, etc in all kind of soil including moorum stony earth and earth mixed with boulders except sheet rock and boulders not requiring blasting including dressing of sides and levelling the 56.879999999999995 Cum 282.9 16091.351999999997 a)-ii Above 1.5mt. Depth 47.568000000000005 Cum 305.36 14525.364480000002 b) Filling the Plinth with excavated materials (excluding rock), in layers not exceeding 0.225 m in depth including cost of watering, ramming, dressing and levelling the top to proper level & gradient, cost of labour, conveyance, loading, unloading, T&P, et 70.711296 Cum 157.2 11115.8157312 c) Supplying and Filling with Sand in Foundation and Plinth in layers not exceeding 20 cm in depth, well watered and compact , top surface dressed and levelled to proper level and gradient including cost of all materials , conveyance, royalties, loading, unl 2.958 Cum 712.4 2107.2792 d) Providing and lying Plain Cement Concrete of proportion (1:4:8) in foundation & floor using 40 mm & down grade black hard crusher broken granite stone metal, washed and screened sharp sand of approved quality from approved quarry including hoisting, lower 2.958 Cum 5643.8 16694.3604 e) Providing and lying Plain Cement Concrete of proportion (1:3:6) in foundation & floor using 40 mm & down grade black hard crusher broken granite stone metal, washed and screened sharp sand of approved quality from approved quarry including hoisting, lower 3.9240000000000004 Cum 6028.0 23653.872000000003 f) Providing 12mm thick cement plaster in cement mortar (1:4) with neat cement punning including racking out joints, scraping and cleaning the surface and finishing the plaster surface smooth using wooden floats, bars, etc only to proper plumbs and level and 15.840000000000002 Sqm 212.4 3364.4160000000006 g) Providing, lifting, hoisting and laying in position machine batched , machine mixed and machine vibrated design mix cement concrete of M-25 Including the cost of Centering and Shuttering (minimum cement content not less than 403 Kg/Cum) grade in reinforc i. Base 5.466 Cum 6845.4 37416.9564 ii. Slab 4.644 Cum 12624.2 58626.78480000001 iii. Wall 21.333 Cum 11908.4 254041.89719999998 h) Providing & fixing TOR Fe-500 HYSD Reinforcement bars of required diameter and approved quality for Reinforced Cement Concrete work including straightening, cutting, bending, binding, welding(if approved) , joining (if necessary), tying the grills, hoisti 42.448049999999995 Qtl. 9275.4 393722.6429699999 i) Supplying all materials, labour, T&P and making MS step iron in 20mm diameter MS steel bars and fixing into walls of man hole/septic tank duly embedded in cement concrete (1:3:6) complete as per specification and direction of the Engineer in charge. 4.0 Each 160.1 640.4 j) Supplying all materials, labour, T&P and laying in trenches ( to level or slope ) and jointing with provision of stiff mixture of cement mortar in proportion of 1:1 for salt glazed stoneware pipes, Grade—A of the following internal diameters including testing of pipes and joints complete. 110mm diameter UPC pipe 12.0 Mtr 993.1 11917.2 |
| 309 | Constructing RCC soak way pit with R.C.C top slab in (1:2:4) mix, inside plaster 12mm thick with cement mortar (1:3) finished with neat cement punning, 12mm thick outside cement plaster (1:3), brick work with K.B bricks having crushing strength not less than 75kg/cm² with dimensional tolerance ± 8 percent in cement mortar (1:4), cement concrete (1:2:4) finished smooth using 12mm size h.g chips, complete as per specification. a) RCC soak way pit of size 1.5m x 1.8m deep 8.0 each 9962.2 79697.6 Borewell Supplying all materials,labour T&P and providing fitting submersible pump with squarrel cage inspection type submerssible type submersible electric motor to run on 3 phase/1 phase line voltage rangingfrom 320 volt to 450 volt conforming to IS :8034/89 a One no. 3 phase 2 H.P 3 stage head range 30 to 54 mtr. Discharge 155 to 200 LMP with outlate dia 32mm. 1.0 Set 19850.0 19850.0 b 2.5 Sq mm cable. 68.0 Mtr 154.0 10472.0 c 40mm dia steel short piece. 2.0 Each 202.0 404.0 d Steel rope wit cover. 70.0 Mtr 35.4 2478.0 e Well Cap. 1.0 Each 202.0 202.0 f 50mm size CI bracket. 1.0 Each 121.2 121.2 g 20mm dia rigid HDPE pipes. 70.0 Mtr 99.8 6986.0 h 8\\" Boring up to 30 mtr. 30.0 Mtr 890.3 26709.0 i 8\\" Boring work Above 30 mtr. 50.0 Mtr 890.3 44515.0 j 8'' ASTM pipe SCH-80 70.0 Mtr 2290.46 160332.2 k Delivery 1.0 Set 2000.0 2000.0 l Labour charges for lowering of summerssible pumpset with pipes and cables etc with testing and commissioning at site. 70.0 Mtr 125.0 8750.0 --------------------- Total PH- 2625217.6111812005 Construction Of Godabarish Mishra Adarsh Prathamik Vidyalaya At Govt. UGHS Ichhapur, Jharigam Block, Ichhapur (GP) , Nabarangpur District (Phase-II) INTERNAL ELECTRICAL WORK FOR SCHOOL BUILDING Sl. No. DESCRIPTION OF ITEMS QUANTITY UNIT RATE AMOUNT Rs. INTERNAL WIRING |
| 310 | Recessed wiring to light point / first light of group control/ call bell point/ exhaust fan point /wall fan point with 1.5 sq.mm FRLSH PVC insulated single core multistrand copper conductor of ISI marked in 20 mm dia non-metalic PVC conduit with 6 Amp, 250 V clip in type switch ISI marked and ceiling rose ISI marked mounted on G.I modular box with face plate & cover of suitable size , with 1.5 sq.mm FRLSH PVC insulated single core multistrand copper conductor as earth wire including all accesories and connection as per direction of Engineer in Charge. Group C 150.0 Nos. 1269.0 190350.0 |
| 311 | Recessed wiring to secondary light point looped from primary light point with 1.5sqmm FRLSH PVC insulated single core multistrand copper conductor of ISI marked with 20mm dia non-metallic PVC conduit with 1.5sqmm FRLSH PVC insulated single core multistrand copper conductor for running earth including 3 plate ISI marked Ceiling rose with all accessories & connection as per direction of Engineer-in-charge.Average Length: 3 mtr |
| 312 | Recessed wiring to ceiling fan point with 1.5sqmm FRLSH PVC insulated single core multistrand copper conductor of ISI marked with 20mm dia non-metallic PVC conduit with 6Amp 250V Modular Switch,Stepped type Moudular Regulator, Base & Cover with 1.5sqmm FRLSH PVC insulated single core multistrand copper conductor for running earth including all accessories & connection as per direction of Engineer in charge. Group c |
| 313 | Recessed wiring to Twin control light point with 1.5 sq.mm FRLSH PVC insulated single core multistrand copper conductor of ISI marked in 20 mm dia non-metalic PVC conduit with 6Amp, 250 V clip in type 2way switch ISI marked and ceiling rose ISI marked mounted on G.I modular box with face plate & cover of suitable size , with 1.5 sq.mm FRLSH PVC insulated single core multistrand copper conductor as earth wire including all accesories and connection as per direction of Engineer-in-charge.Group C |
| 314 | Recessed wiring for 5 / 6 amp socket outlet with 6Amp, 250 V clip in type modular switch ISI marked mounted on G.I moular box with face plate & cover of suitable size including all accesories and connection on same switch board as per direction of Engineer-in-charge. |
| 315 | Recessed wiring for 5 / 6 amp socket outlet with 2 x 1.5 sq.mm FRLSH PVC insulated single core multistrand copper conductor of ISI marked in 20 mm dia non-metalic PVC conduit with 6Amp, 250 V clip in type switch ISI marked mounted on G.I moular box with face plate & cover of suitable size , with 1.5 sq.mm FRLSH PVC insulated single core multistrand copper conductor as earth wire including all accesories and connection on separate board as per direction of Engineer-in-charge.Group C |
| 316 | Recessed wiring for 2 x 6 amp socket outlet controlled by 2 nos 6Amp, 250 V clip in type switch ISI marked mounted on single G.I moular box with face plate & cover of suitable size including all accesories and connection on separate board as per direction of Engineer-in-charge. |
| 317 | Recessed wiring for 6 pin 16 amp socket outlet with 16Amp, 250 V clip in type switch ISI marked mounted on G.I moular box with face plate & cover of suitable size including all accesories and connection as per direction of Engineer-in-charge. |
| 318 | Recessed wiring for A.C/ Power socket outlet with industrial type socket outlet, plug top and metal chained cover in sheet steel enclosure ,20A/32A SP MCB including all accesories and connection as per direction of Engineer-in-charge. |
| 319 | Recessed wiring to exhaust fan/Wall Fan point with 1.5sqmm FRLSH PVC insulated single core multistrand copper conductor of ISI marked with 20mm dia non-metallic PVC conduit with 6Amp 250V Modular Switch, Base & Cover with 1.5sqmm FRLSH PVC insulated single core multistrand copper conductor for running earth including all accessories & connection as per direction of Engineer in charge.Group C |
| 320 | Call bell point |
| 321 | Recessed wiring for 3 x 6 amp socket outlet controlled by 2 nos 6Amp, 250 V clip in type switch ISI marked mounted on single G.I moular box with face plate & cover of suitable size including all accesories and connection on separate board as per direction of Engineer-in-charge. SUBMAIN |
| 322 | Recessed wiring to submain in 4 x 10 sq.mm FRLSH PVC insulated single core multistrand copper conductor of ISI marked confirming to IS-694/1990 in 32 mm dia non-metalic heavy duty PVC conduit 1.6 mm thick along with 2 x 4 sq.mm FRLSH PVC insulated single core multistrand copper conductor as earth wire as equired. |
| 323 | Recessed wiring to submain in 4 x 6 sq.mm FRLSH PVC insulated single core multistrand copper conductor of ISI marked confirming to IS-694/1990 in 32 mm dia non-metalic heavy duty PVC conduit 1.6 mm thick along with 2 x 2.5 sq.mm FRLSH PVC insulated single core multistrand copper conductor as earth wire as equired. |
| 324 | Recessed wiring to submain in 2 x 6 sq.mm FRLSH PVC insulated single core multistrand copper conductor of ISI marked confirming to IS-694/1990 in 25 mm dia non-metalic heavy duty PVC conduit 1.6 mm thick along with 1 x 2.5 sq.mm FRLSH PVC insulated single core multistrand copper conductor as earth wire as equired. |
| 325 | Recessed wiring to submain in 2 x 4 sq.mm FRLSH PVC insulated single core multistrand copper conductor of ISI marked confirming to IS-694/1990 in 20 mm dia non-metalic heavy duty PVC conduit 1.6 mm thick along with 1 x 1.5 sq.mm FRLSH PVC insulated single core multistrand copper conductor as earth wire as equired. |
| 326 | Recessed wiring to submain in 2 x 2.5 sq.mm FRLSH PVC insulated single core multistrand copper conductor of ISI marked confirming to IS-694/1990 in 20 mm dia non-metalic heavy duty PVC conduit 1.6 mm thick along with 1 x 1.5 sq.mm FRLSH PVC insulated single core multistrand copper conductor as earth wire as equired. |
| 327 | Recessed wiring to submain in 2 x 1.5 sq.mm FRLSH PVC insulated single core multistrand copper conductor of ISI marked confirming to IS-694/1990 in 20 mm dia non-metalic heavy duty PVC conduit 1.6 mm thick along with 1 x 1.5 sq.mm FRLSH PVC insulated single core multistrand copper conductor as earth wire as equired. |
| 328 | DB Supply and fixing of following way three pole and neutral, sheet steel, MCB distribution, 415 V on surface / recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, hinged front acrylic cover for the MCB knobs detachable gland plate, interconnections, phosphatized and powder painted including earthing etc. as required wih necessary MCB , RCCB / ISOLATORS as required.Note for MCB- There should be colour indication for tripping On ,Off & Trip/There should be mid trip position for toggles for electrical fault conditions. a) Supply, fixing, erecting, connecting and commissioning of indoor type dust and vermin proof, sheet steel clad ready made, double door horizontal type powder coated wall mounted 4 way TPN Distribution Boards For PDB suitable for 440 V, three phase, 4 wire 50 Hz AC Supply complete with bottom detachable plate for interconnections etc as below.Incommer 1 No-63A FP MCB (10KA) Outgoings-10/20A SP MCB 10KA-12Nos. 3.0 Nos. 14143.0 42429.0 Supply, fixing, erecting, connecting and commissioning of indoor type dust and vermin proof, sheet steel clad ready made, double door horizontal type powder coated wall mounted 4 way TPN Distribution Boards For LDB suitable for 440 V, three phase, 4 wire 50 Hz AC Supply complete with bottom detachable plate for interconnections etc as below.Incommer 1 No-40A FP MCB (10KA) Outgoings-10A SP MCB 10KA-12Nos. 3.0 Nos. 14143.0 42429.0 c) Supply, fixing, erecting, connecting and commissioning of indoor type dust and vermin proof, sheet steel clad ready made, double door horizontal type powder coated wall mounted 4 way TPN Distribution Boards For UPS DB suitable for 440 V, three phase, 4 wire 50 Hz AC Supply complete with bottom detachable plate for interconnections etc as below.Incommer 1 No-40A FP MCB (10KA) Outgoings-10A SP MCB 10KA-12Nos. 3.0 Nos. 14143.0 42429.0 CABLE |
| 329 | Supply & Laying of one number of PVC insulated and PVC seathed / XLPE power cable of 1.1 KV grade of 3.5core 150 sq.mm direct in ground including excavation , sand cushining protective covering and refilling the trench etc. as required. |
| 330 | Supply & Laying of one number of PVC insulated and PVC seathed / XLPE power cable of 1.1 KV grade of 3.5core 95 sq.mm direct in ground including excavation , sand cushining protective covering and refilling the trench etc. as required. |
| 331 | Supply & Laying of one number of PVC insulated and PVC seathed / XLPE power cable of 1.1 KV grade of 4 core 16 sq.mm Aluminium on surface as required. END TERMINATION Supplying and making end termination with brass compression gland and aluminum lugs for following size of PVC insulated and PVC sheathed / XLPE aluminum cable of 1.1 KV as required. |
| 332 | 3.5C x 150 sq.mm |
| 333 | 3.5C x 95 sq.mm |
| 334 | 4C x 16 sq.mm PANEL Supply, installation,testing & commissioning of floor mounting front operated front access extensible type cubicle panel totally enclosed, dust and vermin proof with IP-42 /55 protection with hinged and lockabale doors.CRCA sheets including interconnections,tinned copper crimping lugs, bonding to earth and painting suitable for use at 415 V, 3phase 4 wire 50 Hz system, and to withstand a fault level of 35 KA symmetrical for 1 sec at 415 V complete as per specifications, as required and as below : All switchboards shall have provision for entry of cables from the bottom as required. All live accessible parts shall be shrouded and all equipment shall be finger touch proof. The bus bars shall be insulated with heat shrinkable sleeves.SMC/DMC shrouds and busbar supports shall be used with Indication lamp, C.T , Digital Voltmeter, Digital Ammeter and control fuse etc. complete. |
| 335 | MAIN PANEL with 150A 4P MCCB 36KA -1 No as incomer, 63A 4P MCB 10KA 4Nos,100A 4P Change over Switch 1Nos, 40A 4P MCB 10KA.-9Nos, 32A DP MCB 10KA-3Nos with E.C Busbars with 4nos 65KA VSD along with 4nos 32A SP MCB. EARTHING |
| 336 | Earthing with copper earth plate 600 mm x 600mm x 3.15 mm thick ISI marked including accessories and providing masonary with cover plate having loccking arrangement and watering pipe etc with charcoal and salt as required. |
| 337 | Supplying and laying 25 mm x 6 mm CU earth strip ISI marked at 0.5 meter below ground level as strip earth electrode including soldering etc. as required. |
| 338 | Supplying and laying 25 mm x 6 mm CU earth strip ISI marked on surface or in recess for connection etc as required. |
| 339 | Providing and fixing 8 SWG CU wire on surface or in recess for loop earthing as required. FIXTURE Supply, Installation, Testing and Commissioning of pre-wired fluorescent fiiting / compact fluorescent fitting /LED fitting of all sizes complete with all accessories and lamp etc. directly on ceiling /wall or recessed in false ceiling , including connection with 1.5 sq.mm FR PVC insulated single core multistrand copper conductor and earthing as required. |
| 340 | Ceiling mounted indoor type batten type LED Luminaire with LED Lamp |
| 341 | Ceiling/ Wall mounted type BULK HEAD Luminaire |
| 342 | Supply, Installation, testing and commissioning of 10W Mirror Light |
| 343 | Supply, Installation, Testing and Commissioning of ceiling fan 1200mm sweep, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq.mm FR PVC insulated single core multiatrand copper conductor etc. as required.BLDC 5 Star |
| 344 | Supply, Installation, testing and commissioning of exhaust fan of 250 mm PLASTIC Exhaust Fan (Vntilation Fan) complete, connection, etc as required.250MM CRISP AIR EXH FAN. |
| 345 | Supply & fixing of 18W LED Down Light (S/R) with all accessories. |
| 346 | Supply & fixing of LED 36w 2'x2' Surface/Recessed Mounted Light as required . |
| 347 | Supply & fixing of 6W LED Down Light (S/R) with all accessories. |
| 348 | Supply, Installation, testing and commissioning of wall fan of 400 mm sweep as required.Model-400mm STRIKER HI SPEED. PERFORATED CABLE TRAY Supply and installation of Pregalvanised Perforated type cable trays without cover. The rate shall include bends, Tees, all supporting brackets, anchor fasteners, screws, bolts, nuts etc., including painting of cable trays. Thickness of sheet steel shall be 2 mm. Support sizes similar to ladder type trays. |
| 349 | Size of Cable Tray :300 mm x 50 mm |
| 350 | Size of Cable Tray :150 mm x 50 mm ------------------- TOTAL INTERNAL ELECTRICAL WORK= 2458477.0 |
AI Tender Summary
Tender Timeline
Oct 15, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedOct 29, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 2 daysOct 30, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 3 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender