Tender For Construction Of Indoor Stadium At Govt Hr. Sec School Ramkot Completion Period: 12 Months
Tender Value
2.35 Crore
Estimated cost
Bid Submission
04 Nov 2026
2 days left
EMD
4.71 Lakhs
Bank guarantee accepted
Document Fee
6000
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Kathua → Jammu and Kashmir
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Construction Of Indoor Stadium At Govt Hr. Sec School Ramkot Completion Period: 12 Months
BOQ
| Sl. No. | Item Description |
| 1 | Earth work in bulk excavation by mechanical means (hydraulic excavator) over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 m2 on plan) including disposal of excavated earth lead upto 50 meters and lift upto 1.5 m, as directed by Engineer-in-Charge All kinds of soil : |
| 2 | Extra for every additional lift of 1.5 m or part thereof in excavation/banking excavated or stacked material : All kinds of soil : |
| 3 | Earthwork in excavation by manual means in foundation trenches or drains (not exceeding 1.5m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms,lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soils as directed, within a lead of 1 m. |
| 4 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead upto 50 m and lift upto 1.5 m. |
| 5 | Providing and laying damp-proof Course 50 mm thick with cement concrete 1:2:4 (1 cement:2 coarse sand: 4 graded stone aggregate 20 mm nominal size) and curing complete: |
| 6 | Making plinth protection 50 mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggreagate 20mm nominal size) over 75mm bed of dry brick ballast 40mm nominal size well rammed and consolidated and grouted with fine sand including finishing the top smooth. |
| 7 | Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with: 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) |
| 8 | Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) |
| 9 | Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with: 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) |
| 10 | Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size) |
| 11 | Providing and laying in position specified grade of reinforced cement concrete inclu. curing but excluding the cost of centering, shuttering, finishing & reinforcement. All works upto plinth level 1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone agg. 20 mm nominal size) |
| 12 | Reinforced cement concrete work in walls (any thickness) including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts upto floor five level including curing but excluding cost of centering shuttering, finishing and reinforcement. 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size) |
| 13 | Reinforced cement concrete work in beams, suspended floors, roofs having slope upto 15°, landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases upto five level including curing but excluding the cost of centring, shuttering, finishing and reinforcement with 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size) |
| 14 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 15 | Centring and shuttering including strutting propping etc and removal of form work |
| 16 | Foundations, footings, bases of columns etc. for mass concrete |
| 17 | Suspended floors, roofs, landing, balconies and access platforms. |
| 18 | columns, Pillars,Piers, Abutments, Posts and Struts. |
| 19 | Walls (any thickness) including attached pilasters, buttresses, plinth and string courses etc. |
| 20 | Lintel, beams, plinth beams, girders, bressumers and cantilevers. |
| 21 | Edge of slabs and break in floors and walls Under 20 cms wide. |
| 22 | Brick work with F.P.S. bricks of class designation 75 in foundation and plinth in cement mortar 1:6 ( 1 cement : 6 coarse sand) |
| 23 | Extra for brick work with common burnt clay bricks/cement concrete bricks in superstructure above plinth level upto floor five level |
| 24 | Half brick masonry with common burnt clay (non-modular) bricks of class designation 7.5 in foundations and plinth including curing in : Cement mortar 1:4 ( 1 cement : 4 coarse sand) |
| 25 | Half brick masonry with common burnt clay (non-modular) bricks of class designation in foundations and plinth including curing in : Cement mortar 1:3 ( 1 cement : 3 coarse sand) |
| 26 | Extra for half Brick masonry in superstructure above plinth level upto floor V level. |
| 27 | Extra for providing and placing in position 2 Nos. 6mm dia. M.S. bars at every third course of half brick masonry |
| 28 | Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS : 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer- in-Charge, in skirting, risers of steps and dados over 12 mm thick bed of cement mortar 1:3 ( 1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3 kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. |
| 29 | Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia and length (hold fast lugs or with dash fasteners shall be paid for separately): Sal wood |
| 30 | Providing and fixing ISI marked flush door shutters conforming to IS: 2202 (Part I) decorative type, core of block board construction with frame of 1stclass hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters. 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws. |
| 31 | Providing and fixing panelling or panelling and glazing in panelled or panelled and glazed shutters for doors, windows and clerestory windows (Area of opening for panel inserts excluding portion inside grooves or rebates to be measured). Panelling for panelled or panelled and glazed shutters 25 mm to 40 mm thick.5.0 mm thick glass pane (weighing not less than 12.50 kg/sqm) |
| 32 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc including priming coat with approved steel primer all complete. Fixed to openings / wooden frames with rawl plugs screws etc. |
| 33 | Providing 40x5 mm flat iron hold fast 40 em long including fixing to frame with 10mm diameter bolts, nuts and wooden plugs and embeddings in cement concrete block 30x10x15 cm 1:3:6 mix ( 1 cement : 3 coarse sand :6 graded stone aggregate 20 mm nominal size ) |
| 34 | Providing and fixing bright finished brass door latch with necessary screws etc. complete. :300x16x5 mm |
| 35 | Providing and fixing bright finished brass tower bolts (barrel type) withnecessary screws etc. complete. : 250x10 mm |
| 36 | Providing and fixing bright finished brass handles with screws etc. complete: 9.82.1 125 mm 125 mm |
| 37 | Providing and fixing bright finished brass hanging type floor door stopper with necessary screws, etc. complete |
| 38 | Providing and fixing factory made uPVC white colour sliding glazed window upto 1.50 m in height dimension comprising of uPVC multi-chambered frame with in-built roller track and sash extruded profiles duly reinforced with 1.60 ± .2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), appropriate dimension of uPVC extruded glazing beads and uPVC extruded interlocks, EPDM gasket, wool pile, zinc alloy (white powder coated) touch locks with hook, zinc alloy body with single nylon rollers (weight bearing capacity to be 40 kg), G.I fasteners 100 x 8 mm size for fixing frame to finished wall and necessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, including drilling of holes for fixing hardware's and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealent over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes, wire mesh and silicon sealent shall be paid separately) Note: For uPVC frame and sash extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable. Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made. Three track three panels sliding window with fly proof S.S wire mesh (Two nos. glazed & one no. wire mesh panels) made of (big series) frame 116 x 45 mm & sash 46 x 62 mm both having wall thickness of 2.3 ± 0.2 mm and single glazing bead / double glazing bead of appropriate dimension. (Area of window above 1.75 sqm). |
| 39 | Cost for Hermetically sealed double glazed unit made with 6 mm thick clear float glass both side having 12 mm air gap |
| 40 | Cost of Galavanised wire mesh of average width of aperture 1.4 mm and nominal dia. of wire 0.63 mm |
| 41 | Steel work in built up tubular (round, square or rectangular hollow tubesetc.) trusses etc., including cutting , hoisting , fixing in position andapplying a priming coat of approved steel primer, including welding andbolted with special shaped washers etc. complete. Hot finished welded type tubes Hot finished seamless type tubes Electric resistance or induction butt welded tubes |
| 42 | Structural steel work in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. Welded |
| 43 | Providing and fixing in position collapsible steel shutters with verticalchannels 20x10x2mm and braced with flat iron diagonals 20x5 mm size,with top and bottom rail of T-iron 40x40x6mm, with 40mm dia, steelpulleys, complete with bolts, nuts, locking arrangement, stoppers, handles, including applying a priming coat of approved steel primer |
| 44 | Steel work welded in built up sections/framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works. |
| 45 | Providing and laying matt finished vitrified tile of specified size havingwater absorption less than 0.5% and conforming to IS: 15622 of approved make in all colours and shades in outdoor floors such as footpath, court yard multi models etc., laid on 20mm thick base of cement mortar 1:4 (1cement: 4 coarse sand) in all shapes & patterns including grouting the joints with white cement mixed with matching pigments etc. complete as direction of Engineer-in-Charge. 300x300x9.8 mm |
| 46 | Providing and laying Vitrified tiles in floor with different sizes(thickness to be specified by the manufacturer), with water absorptionless than 0.08% and conforming to IS: 15622, of approved brand andmanufacturer, in all colours and shades, laid with cement based highpolymer modified quick set tile adhesive (water based) conforming to IS:15477, in average 6 mm thickness, including grouting of joints (Paymentfor grouting of joints to be made separately). Size of tile 600x600 mm |
| 47 | Grouting the joints of flooring tiles having joints of 3 mm width, usingepoxy grout mix of 0.70 kg of organic coated filler of desired shade(0.10 kg of hardener and 0.20 kg of resin per kg), including filling /grouting and finishing complete as per direction of Engineer-in-charge.Size of tile 600x600 mm |
| 48 | Providing and laying Polished Granite stone flooring in required designand patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with whitecement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge.Polished Granite stone slab jet Black, Cherry Red, EliteBrown, Cat Eye or equivalent. |
| 49 | Stone tile work for wall lining upto 10m height with special adhesive likearaldite or equivalent over 12mm thick bed of cement mortar 1: 3 (1 cement: 3 coarse sand) including pointing in white cement with an admixture ofpigment to match the stone shade. 8mm thick (mirror polished and machine cut edges) Granite stone of any colour and shade |
| 50 | Extra for providing edge moulding to 18 mm thick Granite stone counters, Vanities etc. including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge. |
| 51 | Providing roofing cover using self-supporting sandwich type PUF sheets of 50mm thickness (50 mm minimum and more at ridges). The roofing system is intended for use in structures with a working height of up to 10 meters. Materials: Outer Sheet: Pre-painted Galvanized Iron (PPGI) sheet, 0.5mm thickness Inner Sheet: Pre-painted Galvanized Iron (PPGI) sheet, 0.3mm thickness Insulation: Polyurethane Foam (PUF) of 50mm thickness Fasteners: Galvanized steel screws and bolts Sealants: Weatherproof sealants compatible with PPGI and PUF. Installation Requirements: The contractor shall ensure that the roofing sheets are installed according to relevant industry standards. All scaffolding supports and framing necessary for the installation of the roofing system shall be provided and installed by the contractor. Proper alignment and spacing of the PPGI sheets shall be maintained to ensure structural integrity and weather tightness. Sealants shall be applied at all joints and penetrations to prevent water ingress. All fasteners shall be installed as per manufacturer's recommendations and in accordance with relevant industry standards Safety Precautions: All workers involved in the installation shall be provided with appropriate Personal Protective Equipment (PPE) including but not limited to safety helmets, gloves, safety glasses, and safety harnesses. Adequate fall protection measures shall be implemented for working at heights exceeding 10 feet, including the use of guardrails, safety nets, or personal fall arrest systems. The contractor shall conduct regular safety inspections and provide necessary training to workers to ensure safe work practices are followed throughout the duration of the project. The rate quoted will be inclusive of all material, scaffoldings (if any), labour etc complete |
| 52 | Providing wall cover using self-supporting sandwich type PUF sheets of 50mm thickness. The roofing system is intended for use in structures any working height . Materials: Outer Sheet: Pre-painted Galvanized Iron (PPGI) sheet, 0.5mm thickness Inner Sheet: Pre-painted Galvanized Iron (PPGI) sheet, 0.5mm thickness Insulation: Polyurethane Foam (PUF) of 50mm thickness Fasteners: Galvanized steel screws and bolts Sealants: Weatherproof sealants compatible with PPGI and PUF. Installation Requirements: The contractor shall ensure that the roofing sheets are installed according to relevant industry standards. All scaffolding supports and framing necessary for the installation of the roofing system shall be provided and installed by the contractor. Proper alignment and spacing of the PPGI sheets shall be maintained to ensure structural integrity and weather tightness. Sealants shall be applied at all joints and penetrations to prevent water ingress. All fasteners shall be installed as per manufacturer's recommendations and in accordance with relevant industry standards Safety Precautions: All workers involved in the installation shall be provided with appropriate Personal Protective Equipment (PPE) including but not limited to safety helmets, gloves, safety glasses, and safety harnesses. Adequate fall protection measures shall be implemented for working at heights exceeding 10 feet, including the use of guardrails, safety nets, or personal fall arrest systems. The contractor shall conduct regular safety inspections and provide necessary training to workers to ensure safe work practices are followed throughout the duration of the project. The rate quoted will be inclusive of all material, scaffoldings (if any), labour etc complete |
| 53 | Providing ridges or hips of width 60cm overall width plain G.S. sheetsfixed with polymer coated J. or L hooks, bolts and nuts 8mm dia G.I.limpet and bitumen washers complete. 0.63 mm thick with zinc coating not less than 275 gram/m2 |
| 54 | Providing valleys of 90cm wide overall in plain G.S. sheets fixed withpolymer coated J. or L. hooks, bolts and nuts 8 mm dia G.I. limpet andbitumen washers complete. 1.25 mm thick with zinc coating not less than 350 gram/m2 |
| 55 | Providing and fixing flashing of 40cm overall width in plain G.S. sheetsfixed with polymer coated J or L hooks, bolts and nuts G.I. limpet andbitumen washers complete, bent to shape and fixed in wall with cementmortar 1:3 (1 cement : 3 coarse sand) 1.00 mm thick with zinc coating not less than 275 gram/m2 |
| 56 | 12mm Cement plaster of mix: 1 : 6 ( 1 cement : 6 fine sand) |
| 57 | 15mm Cement plaster on the rough side of single or half brick wall ofmix: 1 : 6 ( 1 cement : 6 fine sand) |
| 58 | 6 mm cement plaster to ceiling of mix 1 : 3 (1 cement : 3 fine sand) incl. all lifts, carriage of material by MT/HL. |
| 59 | Providing and applying white cement based putty of average thickness 2 mm, of approved brand and manufacture, over the plastered wall surface to prepare the surface even and smooth complete. |
| 60 | Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound) contentWith water thinnable cement primer on wall surface having VOC content less than 50 grams/liter |
| 61 | Distempering with 1st quality acrylic distemper, having VOC (VolatileOrganic Compound) content less than 50 grams/ liter, of approved brandand manufacture, including applying additional coats wherever required,to achieve even shade and colour. Two coats |
| 62 | Finishing walls with textured exterior paint of required shade on Newwork (two or more coats applied @ 3.28 liter/10sqm) over and includingbase coat of exterior primer applied @ 2.20kg/10sqm |
| 63 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade. Two or more coats on new work ( wood work). |
| 64 | Providing and laying factory made chamfered edge Cement Concretepaver blocks in footpath, parks, lawns, drive ways or light traffic parkingetc, of required strength, thickness & size/ shape, made by table vibratorymethod using PU mould, laid in required colour & pattern over 50mmthick compacted bed of sand, compacting and proper embedding/laying ofinter locking paver blocks into the sand bedding layer through vibratorycompaction by using plate vibrator, filling the joints with sand and cuttingof paver blocks as per required size and pattern, finishing and sweepingextra sand complete all as per direction of Engineer-in-Charge. 80 mm thick C.C. paver block of M-30 grade with approvedcolor design and pattern. |
| 65 | Providing and fixing Inaguration stone of granite(size 4'-0\\"x3'-0\\") incl. engraving writing and fixing in wall including Construction of Pedestal Complete Job) : |
| 66 | Providing and laying integral cement based water proofing treatment including preparation of surfaces as required for treatment of roofs, balconies, terraces etc consisting of following operations.a) Applying a slurry coat of neat cement using 2.75kg/sqm of cement admixed with water proofing compound conforming to IS 2645 and approved by Engineer-in-charge over the RCC Slab including adjoining walls upto 300mm height including cleaning the surface before treatment.b) Laying brick bats with mortar using broken bricks/ Brick Bats 25mm to 115mm size with 50% of Cement mortar 1:5 (1 Cement : 5 coarsesand) admixed with water proofing compound conforming to IS 2645 and approved by Engineer-in-charge over 20mm thick layer of cement mortar of mix 1:5 (1 Cement : 5 coarse sand) admixed with water proofing compound conforming to IS 2645 and approved by Engineer in-charge to required slope and treating similarly the adjoining walls upto 300mm height including rounding of Junctions of walls and slabs)c) After two days of proper curing applying a second coat of cement slurry using 2.75kg/sqm of cement admixed with water proofing compound conforming to IS 2645 and approved by Engineer-in-charge.d) finishing the surface with 20mm thick joint less cement mortar of mix 1:4(1 cement: 4 coarse sand) admixed with water proofing compound conforming to IS 2645 and approved by Engineer-in-charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300mm/sq 3mm deep.e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test. All above operations to be done in order and as directed and specified by Engineer in-charge. With average thickness of 120mm and minimum thickness at khurra as 65 mm |
| 67 | Providing and Installation of MAPLE WOOD SPORTS FLOORONG as per specifications laid under:- 1. Vapour Barrier- 0.20 mm thich Polyethylene memberane installed over the concrete base beneath flooring with joints lapped @ 150 mm. 2. Cushion Pads- 19 mm thick cushion pads placed under the wooden sleepers for extra resilience, stapled through the two wings at 300 mm x 300 mm 3. Pine/Fir Wood Sleepers - The under frame made of commercial quality PINE WOOD runners of 70 mm wide x 45 mm thick, treated with anti-termite solution and installed @ 305 mm centre to centre. 4. Maple Flooring – 21 mm Thick with width varying from 57 to 83 mm jointed togeather with Tongue & Groove on all 4 sides on all boards, kiln dried and treated with anti-termites and water resistant lacquer. 5. The surface board to be nailed with Pressure machine to the runner through the tongue only. The floor should be machine sanded and finished with WATER BASED POLYURETHANE POLISH. The Product Should be BWF/ FIBA approved, with warrenty of 7 years and shall be installed after prior approval of Engineer Incharge. |
| 68 | Providing, supplying, fixing, testing and commissioning wind-driven turbo ventilator of 600/610 mm throat diameter, suitable for industrial/warehouse roofing, comprising corrosion-resistant aluminium turbine vanes, stainless steel/aluminium top and base ring, twin maintenance-free sealed ball bearings, complete with minimum 2 mm thick FRP/polycarbonate profiled base plate matching the existing roofing profile, necessary flashing, clamps, brackets, stainless steel nuts, bolts, fasteners, weatherproof sealant, cutting and making good roofing sheets, fixing and making the installation completely watertight, including all labour, T&P, leads and lifts, complete as directed by Engineer-in-Charge. |
| 69 | Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) |
| 70 | Supplying and laying including digging, carrying by lorry, filling River Bed Material including watering & consolidation in layers to specified lines, camber, grades and cross sections. Finished work. |
| 71 | carriages of materials by mechinical transport incl. loading, unloading and stacking complete. |
| 72 | Sand for an lead of 37 kms. |
| 73 | stone agg 40 mm above nominal size for an lead of 37 kms |
| 74 | stone agg 40 mm below nominal size for an lead of 37 kms |
| 75 | brick for an lead of 40 kms. |
| 76 | Providing and fixing white vitreous china extended wall mounting water closet of size 780x370x690 mm of approved shape including providing and fixing white vitreous china cistern with dual flush fitting, of flushing capacity 3 liter/6 liter (adjustable to 4 liter/8 liters), including seat cover, and cistern fittings, nuts, bolts and gasket etc complete. |
| 77 | Providing and fixing wash basin with C.I. brackets, 15mm C.P. brasspillar taps, 32 mm C.P. brass waste of standard pattern, includingpainting of fittings and brackets, cutting and making good the wallswherever required : White Vitreous China Wash basin size 550x400 mm with a pair of 15 mm C.P. brass pillar taps. |
| 78 | Providing and fixing white vitreous china flat back or wall corner typelipped front urinal basin of 430x260x350mm and 340x410x265 mm sizesrespectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I. clamps complete,including painting of fittings and brackets, cutting and making good thewalls and floors wherever required: One urinal basin with 5 literwhite P.V.C automatic flushing cistern |
| 79 | Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing Rectangular shape 1500x450 mm |
| 80 | Providing and fixing toilet paper holder with Flap made out of C.P Brass |
| 81 | Providing and fixing PTMT soap dish holder having length of 138mm, breadth 102mm, height of 75mm with concealed fitting arrangements, weighing not less than 106gms. . |
| 82 | Providing and fixing PTMT towel ring trapezoidal shape 215 mm long, 200 mm wide with a minimum distance of 37 mm from wall face with concealed fittings arrangements of approved quality and colour, weighing not less than 88 gms. |
| 83 | Providing and fixing 15 mm nominal bore C.P. brass angle valve forbasin mixer and geyser points of approved make conforming to IS : 8931 |
| 84 | Providing and fixing 8 mm dia C.P. / S.S. Jet with flexible tube upto1 metre long with S.S. triangular plate to European type W.C. ofquality and make as approved by Engineer - in - charge. |
| 85 | Providing and fixing CP Brass 32mm size Bottle Trap of approvedquality & make and as per the direction of Engineer-in-charge. |
| 86 | Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet150 mm diameter |
| 87 | Providing and fixing CP Brass Single lever telephonic wall mixer ofquality & make as approved by Engineer in charge.(a) 15 mm nominal dia |
| 88 | Providing and fixing 15 mm nominal bore C.P. brass bib cock of approved quality conforming to IS : 8931 |
| 89 | Providing and fixing 15 mm nominal bore C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms |
| 90 | Providing and fixing 15 mm nominal bore C.P. stop cock (concealed) of standard design and of approved make conforming to IS : 8931 |
| 91 | Providing and fixing on wall face and on ground un-plasticized Rigid PVC rain water pipes conforming to IS: 13592 Type A including jointing with seal ring confirming to IS:5283 leaving 10 mm gap for thermal expansion. (i) Single socketed pipes |
| 92 | 75 mm diametre |
| 93 | 110 mm diameter |
| 94 | Providing and fixing on wall face and on ground un-plasticized - PVC moulded fittings / accessories for un plasticized Rigid PVC rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion. |
| 95 | Coupler 75 mm |
| 96 | Coupler 110 mm |
| 97 | Bend 87.5° 75 mm |
| 98 | Bend 87.5° 110 mm bend |
| 99 | Shoe (plain) 75 mm shoe |
| 100 | Shoe (plain) 110 mm shoe |
| 101 | Providing and Fixing of Floor Traps 110 mm with double chrome plated Cover one Grated and one closed and all other fittings required. Makes:- Astral/SFMC/Finolex |
| 102 | Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement: 4 coarse sand ) with R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5coarse sand (zone- III) : 3 graded stone aggregate 20 mm nominalsize), foundation concrete 1:4:8 mix (1 cement : 4 coarsesand (zone- III): 8 graded stone aggregate 40 mm nominal size),inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3coarse sand) finished withfloating coat of neat cement and making channels in cement concrete1:2:4 (1 cement : 2 coarse sand : 4graded stone aggregate 20 mmnominal size) finished with a floatingcoat of neat cement complete as perstandard design : Inside size 90x80 cm and 45 cm deep including C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight ofcover and frame to be not less than 38 kg (weight of cover 23 kg andweight of frame 15 kg) :With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 |
| 103 | Supply, Installation of PVC Gully Trap of Size 110 mm |
| 104 | Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) up to haunches of P.V.C pipes including bed concrete as per standard design : 110 mm dia. PVC SWR socketed pipe with rubber ring joints as per IS:13592 Type-B |
| 105 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes,having thermal stability for hot and cold water supply, including allCPVC plain and brass threaded fittings. This includes jointing of pipesand fittings with one step CPVC solvent cement and testing of jointscomplete as per direction of Engineer-in-charge.(SDR-11) Internal work Concealed fixing the pipe with clamps at 1.00 meter spacing including cutting chases and making good the wall etc. |
| 106 | 15mm nominal outer dia pipes |
| 107 | 20mm nominal outer dia pipes |
| 108 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes,having thermal stability for hot and cold water supply, including allCPVC plain and brass threaded fittings. This includes jointing of pipesand fittings with one step CPVC solvent cement and testing of jointscomplete as per direction of Engineer-in-charge.(SDR-11) Internal work-exposed on wall with clamps at 1.00 meter spacing |
| 109 | 32mm nominal outer dia pipes. |
| 110 | 40mm nominal outer dia pipes. |
| 111 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes,having thermal stability for hot and cold water supply, including allCPVC plain and brass threaded fittings. This includes jointing of pipesand fittings with one step CPVC solvent cement and testing of jointscomplete as per direction of Engineer-in-charge. External work including trenching and refilling etc. complete 40mm nominal outer dia pipes. |
| 112 | Providing and fixing unplasticised PVC connection pipe with brass unions: 45 cm length 15 mm nominal bore |
| 113 | Cutting holes upto 30x30 cm in walls including making good the same with common burnt clay F.P.S.(non modular) bricks |
| 114 | Providing & fixing full way lever operated forged brass ball valve of brass body with forged brass hard chrome plated steel ball tested to a pressure not less than 16 Kg / sqcm with threaded / flanged joints complete with nuts, bolts, gaskets, washers etc. |
| 115 | 50 mm Diameter |
| 116 | 40 mm Diameter |
| 117 | Providing and placing on terrace (at all floor levels) polyethylene waterstorage tank ISI : 12701 marked, with cover and suitable lockingarrangement and making necessary holes for inlet, outlet and overflowpipes but without fittings and the base support for tank |
| 118 | Providing and fixing on wall 50 LTRS Electric Geyser with ABS Body. |
| 119 | Provifding and Fixing of Monoblock Pumpset with Brass Foot valve and Discharge of 120 LPM at a Head of 30 Meters along with Control Panel and other accessories to make the pump usable for water lifting from under ground Tank to Overhead Tank |
| 120 | Supplying,Installation of 9 Mtr. Long Pole(PCC WL-300Kg , ST-410 SP33) |
| 121 | Supply,installation of Structural Steel as per Standard Approved Drawing |
| 122 | Supply,Installation and Commissioning of 11 KV Air Break Switch(200 Amps). |
| 123 | Supply,Installation of Gapless Surge Arrestor,9 kV ,10 kA ,LA with polymer housing, Stn. Type |
| 124 | Supply,Installation of 11 KV HG Fuse Unit . |
| 125 | Supply,Installation of Disc Insulator(B&S)70 KN suitable for 100 sq.mm Triple AAAC. |
| 126 | Supply and Installation of 100 Sq.mm AAAC Triple AAAC. |
| 127 | Supply,Installation of 11 KV Pin Insulator suitable for 100 sq.mm Triple AAAC. |
| 128 | Supply and Erection of 150 mm Dia. Heavy Class G.I Pipe for the Cable Protection. |
| 129 | Supply and Installation of Anti Climbing Device |
| 130 | Supplying, installation, testing and commissioning of following capacity (continuous loading) BEE 3 Star rated (Corresponding Level as per BIS amended upto date of receipt of tender) , 11/0.433 KV step down, 3 Phase, 50 Hz, Dyn 11 vector group, KNAN [K(K-Class insulating liquid) Natural Air Natural] copper wound transformer (Electrolytic grade 99.9% pure copper,Core made of first grade Cold Rolled Grain Oriented (CRGO) Core grade MOH or better),Dielectric material shall be type -A, suitable for out door/indoor applications with Offload Tap Changer in range of +5% to -15% in steps of 2.5%, having cable end boxes on HV side suitable for 3x300 sqmm XLPE cable of 11 KV grade, including bus trunking arrangement on LV side including supplying and laying of copper conductor multicore control cable from transformer to HT breaker/panel for safety tripping, complete with all accessories and safety provisions as per relevant IS 1180 (Part-3) including first filling of filtered dehydrated Synthetic organic Ester oil, i/c supplying and grouting of suitable M.S. Channel with all accessories and transformer shall be confirming to IS : 2026 (Part 1 to Part 5), IS : 1180 (Part-3) and as per CPWD specifications complete in all respects etc as required at site. The maximum flux density in any part of the core and yoke at rated voltage and frequency shall be such that the flux density with +12.5 percent combined voltage and frequency variation from rated voltage and frequency does not exceed 1.9 Tesla. The permissible temperature-rise shall not exceed 400C for oil and 450C for winding up to 200 KVA and 450C for oil and 500C for winding for above 200 KVA. Inside of tank shall be painted with varnish or liquid resistant paint. For external surfaces one coat of thermo setting powder paint or one coat of epoxy primer followed by two coats of polyurethane base paint shall be used.IS: 1180 (Part 3) shall be referred for paint thicknessfor normal to medium corrosive atmosphere. For highly polluted atmosphere and special application external paint work shall be as per direction of Engineer-in-Charge. Design ambient condition : a) air temperature 500C, b) Relative Humidity 90 % Max, c)Seismic Zone as per location of site, d) Altitude as per location/site. Noise level Shall not exceed limits as per NEMA TR-1 with all accessories running measured as per IEC 551 / NEMA standard. The transformer should have QR code which should contain drawing, test report OEM manual,Geo- Tag of manufacturing location etc. Marking Each transformer shall be provided with rating plate made of anodized aluminum/ stainless steel material securely fixed on the outer body, easily accessible,as per IS: 1180 Part- 3. The entries on the rating plate shall be indelibly marked. Fitting and Accessories : The following fittings shall be provided:- a) Two earthing terminals with the earthing symbol b) Oil level gauge indicating oil level at minimum, 30°C and maximum operating temperature; c) Air release device (for non-sealed type transformers) d) Rating and terminal marking plates; e) Silica gel breather f) Drain-cum-sampling valve (¾″ nominal size thread, IS 554) preferably steelwith plug for three phase transformers; g)Thermometer pocket with cap; h) Oil filling holes having (1¼″ nominal size thread) with cover (for sealed type transformers without conservator); i)Lifting lugs for the complete transformer as well as for core and winding assembly; j) Pressure relief device or explosion vent above 200 kVA; k) One filter valve on the upper side of the tank (for transformers above 200 kVA); l) Unidirection al flat rollers (for transformers above 200 kVA); m) Inspection hole (for transformers above 200 kVA); n) HV side neutral grounding strip(where one of the HV bushing terminal is connected to earth); o) Buchholz relay for transformers above 800 kVA. p) Arcing horns or suitable rating lightning arrestors for HT side – 3 Nos. q) Bird guard; r) Oil temperature indicator and winding temperature indicators for transformers above 200 kVA with suitable tripping mechanism above permissible limit s) Jacking pads (for transformer above 1 600 kVA); t)Additional Neutral separately brought out on bushingfor earthing. u) Magnetic oil level gauge (for transformer above 1600 kVA) with low oil level alarmcontact; v) Non return valve (for conducting pressure test); w) Pressure relief device or explosion vent x). Monogram Plate y) Inspection cover z). Detachable type radiators with top and bottom shutoff valve. aa)Oil Conservator with Oil level indicator, minimum level marking and drain plug for all aluminum/ stainless steel material securely fixed on the outer body, easily accessible,as per IS: 1180 Part- 3. The entries on the rating plate shall be indelibly marked. Fitting and Accessories : The following fittings shall be provided:- a) Two earthing terminals with the earthing symbol b) Oil level gauge indicating oil level at minimum, 30°C and maximum operating temperature; c) Air release device (for non-sealed type transformers) d) Rating and terminal marking plates; e) Silica gel breather f) Drain-cum-sampling valve (¾″ nominal size thread, IS 554) preferably steelwith plug for three phase transformers; g)Thermometer pocket with cap; h) Oil filling holes having (1¼″ nominal size thread) with cover (for sealed type transformers without conservator); i)Lifting lugs for the complete transformer as well as for core and winding assembly; j) Pressure relief device or explosion vent above 200 kVA; k) One filter valve on the upper side of the tank (for transformers above 200 kVA); l) Unidirection al flat rollers (for transformers above 200 kVA); m) Inspection hole (for transformers above 200 kVA); n) HV side neutral grounding strip(where one of the HV bushing terminal is connected to earth); o) Buchholz relay for transformers above 800 kVA. p) Arcing horns or suitable rating lightning arrestors for HT side – 3 Nos. q) Bird guard; r) Oil temperature indicator and winding temperature indicators for transformers above 200 kVA with suitable tripping mechanism above permissible limit s) Jacking pads (for transformer above 1 600 kVA); t)Additional Neutral separately brought out on bushingfor earthing. u) Magnetic oil level gauge (for transformer above 1600 kVA) with low oil level alarmcontact; v) Non return valve (for conducting pressure test); w) Pressure relief device or explosion vent x). Monogram Plate y) Inspection cover z). Detachable type radiators with top and bottom shutoff valve. aa)Oil Conservator with Oil level indicator, minimum level marking and drain plug for all transformers of capacity 50 KVA and above. bb) Necessary hardware, clamps,lugs etc. for termination on HV/MV etc. for all transformers. 63 KVA |
| 131 | Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thickincluding accessories, and providing masonry enclosure withcover plate having locking arrangement and watering pipe of2.7 metre long etc. with charcoal/ coke and salt as required. |
| 132 | Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required. |
| 133 | Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/terminating with G.I. nut, bolt, spring, washer etc. as required.(Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm) |
| 134 | Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 Meter long etc.with charcoal/ coke and salt as required. |
| 135 | Providing and fixing 25 mm X 5 mm copper strip in 40 mm dia G.I. pipe from earth electrode including connection with brass nut, bolt, spring, washerexcavation and re-filling etc. as required. |
| 136 | Supplying and laying 25 mm X 5 mm copper strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of brass nut bolt & spring washer spaced at 50mm) |
| 137 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. Group C |
| 138 | Wiring for Light /Power Plug with 2 x 4 sq.mm FRLS PVC Insulated Copper Conductor single core cable in surface/Recessed medium class PVC Conduit along with 1 No. 4 sq.mm FRLS PVC Insulated copper conductor single core cable for loop earthing as required. |
| 139 | Wiring for Circuit/Submain Wiring along with earth Wire with the following Sizes of FRLSPVC insulated copper conductor,single core Cable in surface/ Recessed medium class PVC conduit as required. |
| 140 | 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire |
| 141 | 4 X 6 sq. mm + 2 X 6 sq. mm earth wire |
| 142 | 4 X 10 sq. mm + 2 X 6 sq. mm earth wire |
| 143 | Supplying and drawing following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. 1 x 1.5 sq. mm |
| 144 | Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excludingmodular plate etc. as required. |
| 145 | Supplying and Fixing suitable size G.I box with modular plate and cover in front on surface or in recess,including providing and fixing 6 pin 15/16 amps modular socket outlet and 15/16 amps modular switch, connection, painting etc. as required. |
| 146 | Supply installation testing and commissioning of Ceiling Fan 3 Star Rated with Voltage Range 90 V to 300 V,Min. Air Delivery 212 CMM,Service Value 5.3 Cu.m/min/watt,Aluminium Blades ,including wiring the down rods of standard length(Upto 45 cm)with 1.5 Sq. mmFR PVC insulated,copper conductor,single core cable including providing and fixing phenolic laminated sheet cover on the Fan Box etc as Required. 1200 MM |
| 147 | Supplying and fixing modular blanking plate on the existing modular plate and switch box excluding modular plate as required |
| 148 | Supplying & fixing suitable size GI box wih modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, \\"C\\" curve including connections, painting etc. as required.(For Geyser ) |
| 149 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. |
| 150 | 25 mm |
| 151 | 32 mm |
| 152 | Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 4 way (4 + 12), Double door |
| 153 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single Pole |
| 154 | Supplying and fixing following rating, Four pole, 415 V, 10 Ka M.C.Bin the existing MCB DB complete with connections, testing andcommissioning etc. as required. |
| 155 | 32 A F.P MCB 10 Ka \\"C\\" Curve |
| 156 | 40 A F.P MCB 10 Ka \\"C\\" Curve |
| 157 | Supplying and fixing single pole blanking plate in the existingMCB DB complete etc. as required. |
| 158 | Supply installation testing and commissioning of 2.2 KVA Sine Wave Inverter , Input 1 Phase 3 wire and output 1 phase 3 wire with 2 Nos of 12 V 200 aH Battery. |
| 159 | Supply,Installation,Testing and Commissioning 486 Cu.m/Hr. AC 220-240 Volts, 50 Hz exhaust fan made out of Metal Body with inbuilt thermo cutoff Protection and Noise Level not exceeding 37 dB of Following Sizes including connection etc. complete as required . 300 mm |
| 160 | Supply,Installation,Testing and Commissioning of 600 mm (24-inch) wall fan heavy-duty industrial or commercial air circulator to deliver high-volume airflow with Motor Speed: 1400 to 1440 RPM (Rotations Per Minute),Air Delivery: 250 to 280 CMM (Cubic Metres per Minute),Power Consumption: 150W to 190W,Voltage/Frequency: 220V–240V AC, 50 Hz (Single Phase) including Connections as per the Satisfaction of the Engineer Incharge. |
| 161 | LED Flood Light, powder coated pressure die cast aluminium (System lumen efficacy ≥120 and<135 lm/Watt).Supplying, Installation, Testing & Commissioning of Flood Light, powder coated pressure die cast aluminium body with built in or separate driver as per the requirement with Driver efficiency >85%, Input voltage: Input voltage: 140-270 Volt AC, frequency 50/60 hz, Operating temp range -5 0C to 50 0C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000 -3-2, P. F.≥0.95, IP-66,IK-10, CRI >70, under voltage and over voltage protection, EMI-EMC as per CISPR-15, lenses for beam angle 30 deg-120deg as per the application and the project requirement, suitable tilt able fitting, life time (LED, Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K /4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Colour Matching) <5,Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 and <135 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted.. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). 250 watt |
| 162 | LED Down lighter (SMD Type) (System lumen efficacy ≥ 105 < 120 lm/Watt )Supplying, Installation, Testing & Commissioning of LED Recessed/ surface Down lighter (Round/square/ Rectangular) SMD type of following body material with PMMA and prismatic diffuser and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz,Operating temp range -50C to 400C, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80,UGR (Unified Glare Rating) < 19, Flicker free (flicker should be below 5%), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends, CCT 3000°K /4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM (Standard Dev iation Colour Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be confirming to relevant BIS standards. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing Complete in all respect i/c external connectionswith 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc.as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 and <120 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C) Powder coated die cast /Extruded aluminium Body including trim 18 watt |
| 163 | LED Street light fixture, powder coated pressure die cast aluminium body (System lumen efficacy ≥105 <120 lm/Watt) Supplying, installation, Testing & Commissioning of Street light LED fixture powder coated pressure die cast aluminium body with driver as per the requirement with Driver efficiency >85%, Input voltage: 140-270 Volt AC, frequency 50/60 hz,Operating temp range -5 0C to 50 0C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2, P. F.≥0.95, IP-66,IK-10, CRI >70,under voltage and over voltage protection, EMIEMC As per CISPR -15, lenses for beam angle as per IESNA type I/II/III as per the width of the road and the project requirement., suitable to fit in up to 65mm dia pipe, life time (LED, Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin),SDCM (Standard Deviation Colour Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty.System lumen efficacy ≥105 <120 lm/Watt output .LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). 120 watt |
| 164 | Supply installation testing and commissioning of IP:20 Decorative Light 10W-12 W +- 1 W LED Surface Mounted 2 ft. with system lumen efficacy of 100 lm/W and P.F >0.9 THD <20% CCT 6500K,CRI 80 .The LED should have life of 50000 Burning Hours at L70.The input voltage shall be 150 V to 270 V.The fixture should have inbuit surge protection of 2KV.Certification-LM 79 and LM 80.The test report should be from Govt. Approved Lab/inhouse NABL Lab. |
| 165 | Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. |
| 166 | Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required. |
| 167 | Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/terminating with G.I. nut, bolt, spring, washer etc. as required.(Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm) |
| 168 | Supplying,Installation,Testing and Commissioning of Cubical Type IndoorLT Panel Board Suitable for 415 V 3 Phase 4 Wire 50 HZ AC Supply System including Incomers,Out Goings,Bus Bars etc. as required as per the Following Description.(IP:42)( Building Distribution Panel Board ) .The successful tenderer shall take prior approval for the panel builder/fabricator alongwith G.A. drawing, wiring diagrams, single line diagram before start of fabrication of LT panel.Circuit breaker shall be capable of carrying the full load current defined for 50 degree Celsius without any derating.The Panel Builder Shall be CPRI /ERDA/ANY NABL ACCREDITED LAB approved.Refer SLD .(Toilet Complex with Bath Huts) Load Bearing Members to be made out of 2.0 mm CRCA Sheet. Partitions to be made out of 1.6 mm CRCA Sheet Gland Plates to be 3.0 mm Thick. |
| 169 | INCOMER Adj. TMR Based MCCB 63 Amps FP Icu=Ics=100% Breaking Capacity 36 KA |
| 170 | INCOMER 100 A,415 Volts 50Hz Aluminium Busbar set of 4 strips |
| 171 | INCOMER Digital Metering devices, comprising of Voltmeter, Ammeter, Selector Switch, Indicating Lamp, CT Set etc. |
| 172 | OUTGOINGS Manual Changeover Switch 63 A F.P 415 Volts Ac-23 Duty |
| 173 | OUTGOINGS F.P 32 A 10 Ka \\"C\\" Curve MCB |
| 174 | OUTGOINGS F.P 40 A 10 Ka \\"C\\" Curve MCB |
| 175 | Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket,bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required. 200 mm dia (OD-200 mm & ID-175 mm nominal) |
| 176 | Supplying and Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in groundin Existing DWC Pipe including excavation, sand cushioning, protective covering and refilling the trench etc as required. 3.5 C X 35 Sq.mm A2XFY |
| 177 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 3½ X 35 sq. mm (32mm) |
| 178 | Providing and fixing of lightning conductor finial, made of 25 mm dia 300 mm long, G.I. tube, having single prong at top, with 85 mm dia 6 mm thick G.I. base plate including holes etc. complete as required. |
| 179 | Fixing of lightning conductor finial (single prong) with base plate including holes etc. complete as required. |
| 180 | Jointing copper / G.I. tape (with another copper/ G I tape, base of the finial or any other metallic object) by riveting / nut bolting/ sweating and soldering etc as required. |
| 181 | Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required.(For horizontal run) |
| 182 | Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required.(For vertical run) |
| 183 | Supply installation testing and commissioning of 200W, HighBay IP66 Flood Light with System efficacy of 110 lm/W, PC lense with Toughened Glass Cover with IK rating IK07. LED FloodLight shall be made up of Die cast Aluminium Housing for better heat decapitation. L70 life of 50000 Hrs. P.F.>0.95 with THD<10% ,CCT 5700 K,CRI 70,Surge Protection 5 Kv. Input voltage range of 150V to 270V.Certification:- LM79 & LM80 test report should be from govt approved Inhouse NABL lab/ government of India authorised lab. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Oct 15, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedNov 04, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 2 daysNov 05, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 3 daysTender Documents
Download All (ZIP) ↓
Disclaimer