Defence Statutory Bodies & Commissions/Committees Closing in 22 days TDR #58053667

Tender For Provn Of Lightening Arrestor And Allied Works At Certain Location At 1 Wing, Provn Of Ceiling Fans For Smqs, And Provn Of Air Circulators At Certain Location Under Ge (Af) Srinagar.Job No. (I) 1Wg/Mr-01/2026-27, (Ii) 1Wg/Mw-07/2026-27, (Ii

Issued by Statutory Bodies & Commissions/Committees · Budgam, Jammu and Kashmir
Tender Value
15.50 Lakhs
Estimated cost
Bid Submission
07 Nov 2026
22 days left
EMD
31000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Budgam → Jammu and Kashmir
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Provn Of Lightening Arrestor And Allied Works At Certain Location At 1 Wing, Provn Of Ceiling Fans For Smqs, And Provn Of Air Circulators At Certain Location Under Ge (Af) Srinagar.Job No. (I) 1Wg/Mr-01/2026-27, (Ii) 1Wg/Mw-07/2026-27, (Iii) 1Wg/Mw-08/2026-27

BOQ

Name of Work:- PROVN OF LIGHTENING ARRESTOR AND ALLIED WORKS AT CERTAIN LOCATION AT 1 WING, PROVN OF CEILING FANS FOR SMQs, AND PROVN OF AIR CIRCULATORS AT CERTAIN LOCATION UNDER GE (AF) SRINAGAR.Job No. (i) 1WG/MR-01/2026-27, (ii) 1WG/MW-07/2026-27, (iii) 1WG/MW-08/2026-27
Sl. No. Item Description
1Supply, install, test and commission a single-point air-termination rod of solid copper, 12 mm diameter and 300 mm minimum length, complete with compatible corrosion-resistant base/support, clamps, fasteners and connection to the roof-conductor network. Installation shall comply with the approved lightning-protection layout and IS/IEC 62305. The rate shall include all tools, access arrangements, making good of fixing locations and removal of debris. No dissimilar-metal contact shall be permitted unless separated by an approved bimetallic connector.
2S&F copper strip, 20 mm x 3.15 mm, for roof conductors and down conductors of the lightning-protection system, including UV-resistant insulating saddles, fixing screws, clamps, bends, joints and terminations. Maintain the routing, separation distances and fixing intervals . Joints shall be by exothermic weld or approved high-conductivity bolted connector, accessible for inspection and protected against corrosion. Rate includes all tools, access arrangements, making good and site clearance.
3Supply, install, test and commission one complete lightning-protection air terminal set, comprising air terminal, insulated coupler, 4.0 m mast, base plate, anchors and all accessories. The quoted protection radius of 42 m shall be demonstrated by the manufacturer for the approved installation height and the design level of protection; it shall not be accepted as a fixed radius independent of height. The set shall comply with the applicable approved standard (NF C 17-102 for ESE systems, or IS/IEC 62305 for conventional systems), be supported by manufacturer test certificates and be compatible with the approved layout. Mast: GI, hot-dip galvanized after fabrication, 48 mm outer diameter minimum, 3.2 mm wall minimum, 4.0 m overall height, with a 220 mm diameter x 10 mm minimum base plate and four 16 mm anchor holes. Provide approved insulating coupler, base anchors, cable ties, clamps, conductor connection and all accessories. Installation on a concrete surface shall be by approved anchors; structural adequacy and waterproofing/making-good are included. Rate includes all tests, drawings, certificates and commissioning.
4Supply, install, test and commission maintenance-free chemical earthing comprising one copper-bonded steel electrode, 3.0 m long x 17 mm minimum diameter, with low-carbon steel core (SAE 1018 or equivalent) and 250 microns minimum electrolytic copper bonding. Provide compatible copper-bonded/GI test terminal clamp, earth lead connection, inspection chamber, conductive backfill compound, excavation, installation and reinstatement. Backfill compound shall be RoHS-compliant, non-corrosive, non-leaching and from an approved manufacturer; proprietary names are not mandatory and 'or approved equivalent' shall apply. Install strictly to the manufacturer’s written instructions and IS 3043. The electrode top shall be permanently sealed with conductive concrete and the copper strip shall terminate at an accessible earth test point. Submit pre- and post-installation test results using an approved earth-resistance tester. For a lightning-protection earth, the measured resistance shall not exceed 10 ohms, or the lower value stated in the approved design. Do not use a material-resistivity claim as a substitute for measured earth resistance.
5S&F heavy-duty UV-resistant HDPE/FRP inspection pit cover and frame for the chemical-earthing chamber, complete with lifting arrangement, marking 'EARTH PIT', seating, bedding and making good. Clear opening shall suit the approved chamber and shall not be less than 300 mm x 300 mm. The cover shall be suitable for the actual installation location and load class.
6S&F test point terminal block made out of Gun metal or phosphorous bronze of size 75 mmx75 mm x25 mm drilled and screwed including 03 Nos 8mm dia 25mm long hexagonal head screws, complete all as specified and directed.
7Excavation in trenches, n. exc 1.5 m wide and n. exc 1.5m depth and getting out in for foundation of pole, stay, laying of cable and pipe in any type of soil etc., complete all as specified and directed
8Returing, filling in incl spreading, levelling, watering and well ramming in layers n exc 25cm thick after laying of the cables,jointing & testing, complete all as specified and directed.
9Removing excavated material to a distance n.exc 50 m & depositing where directed at a level n. exc 1.50 m above the starting point, complete as specified and directed.
10S&F 50 mm nominal outside diameter DWC (double-wall corrugated) HDPE pipe with 32 mm minimum clear internal diameter for protection of earthing strip/cable, conforming to IS 14930 or IS 16205, including snap-fit couplers, bends, end caps, draw wire where required, supports and all fixing accessories. Pipe shall be continuous and free from sharp edges; provide suitable bends and protection at entries/exits so that the earth conductor is not damaged. Rate includes all cutting, jointing, making good and testing of the protected route.
11M&L for copper earthing complete with 600mm×600mm×3.15mm thick electrode, buried directly in ground (earth pit not less than 2.25 m deep below ground level) with top edge of the plate not less than 1.5 m below normal ground level, connected to 20×3mm copper strip as earthing lead by means of bolts, nuts, check nuts and washers of copper all as shown in electrical plate No. 3 connected to earth test point & to main switch board with & including adequate quantity of charcoal dust and common salt alround earth plate & 50 mm dia GI pipe medium grade for earth lead protection pipe for suitable length and GI pipe 20 mm dia medium grade for watering pipe with funnel & wire mesh including necessary earth work and PCC (1: 3 : 6) type C-1 for earth pit , internal surface of concrete shall be given 10mm thick plaster in CM 1:4 and 40 mm thick precast RCC cover 1 : 2 : 4 ,type B-1( using 20 mm graded crushed stone aggregare ) reinforced with 8 mm dia TMT bars @ 75 mm c/c both ways with 12mm dia round bar as in handle , complete all as specified and directed. NOTE : (i) The cost of earth lead and its protection pipe upto and including 7.5 m only from the top of earth electrode are deemed to be included under this item and additional earth lead , if any, required at site shall be measured and paid for separately under appropriate item of Schedule `A’/BOQ.(ii) Any joint in earth lead from earth electrode to test point shall not be allowed/permitted.
12M&L for earthing complete with galvanized steel earth plate electrode 600mm x 600mm x 6mm buried directly in ground vertically to a depth not less than 2.25 m below normal ground level (with top edge of earth plate not less than 1.5 metre below ground level) connected to galvanized iron earth strip 32 x 6 mm (main earthing lead) by means of galvanized bolts, nuts and washers all as shown in electrical plate No 3 of MES Schedule Part-I (2009) connected to earth test point & to main switch board with & including adequate quantity of charcoal dust and common salt alround earth plate & 40 mm dia GI pipe medium grade for earth lead protection pipe for suitable length and GI pipe 20 mm dia medium grade for watering pipe with funnel & wire mesh including necessary earth work and PCC (1: 3 : 6) type C-1 for earth pit , internal surface of concrete shall be given 10mm thick plaster in CM 1:4 and 40 mm thick precast RCC cover 1 : 2 : 4 ,type B-1( using 20 mm graded crushed stone aggregare ) reinforced with 8 mm dia TMT bars @ 75 mm c/c both ways with 12mm dia round bar as in handle , complete all as specified and directed. NOTE : (i) The cost of earth lead and its protection pipe upto and including 7.5 m only from the top of earth electrode are deemed to be included under this item and additional earth lead , if any, required at site shall be measured and paid for separately under appropriate item of Schedule `A’/BOQ.(ii) Any joint in earth lead from earth electrode to test point shall not be allowed/permitted.
13S&F, installation, testing and commissioning of 1200 mm sweep ceiling fan (BLDC) with electronic regulator , 5-Star rated, Class-B insulation of copper winding, with blades, down rod, canopies, minimum air delivery 210 m³/min , complete with safety pin, nuts, bolts, washers and all other accessories, suitable for 230 V, 50 Hz, with service value 6.00 BEE including connecting with suitable-size copper wire, writing of MES No. with black enamelled paint, complete all as specified and as directed by the Engineer-in-Charge.
14S&F, installation, testing and commissioning of 600 mm sweep ceiling fan with electronic regulator, Class-B insulation of copper winding, with blades, down rod, canopies, minimum air delivery 120 m³/min, minimum speed 850 RPM, complete with safety pin, nuts, bolts, washers and all other accessories, suitable for 230 V, 50 Hz, including connecting with suitable-size copper wire, writing of MES No. with black enameled paint, complete all as specified and as directed by the Engineer-in-Charge.
15S&F, installation, testing and commissioning of 400 mm sweep wall-mounted fan, suitable for 230 V, 50 Hz, , speed 1350 RPM, minimum air delivery 75 m³/min, complete with suitable wall-mounting arrangement/bracket, screws, nuts, bolts, washers, fasteners and all other accessories required for safe and complete installation, complete as directed by the Engineer-in-Charge. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 58053667
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 15.50 Lakhs
LAST DATE 07-11-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Provn Of Lightening Arrestor And Allied Works At Certain Location At 1 Wing, Provn Of Ceiling Fans For Smqs, And Provn Of Air Circulators At Certain Location Under Ge (Af) Srinagar.Job No. (I) 1Wg/Mr-01/2026-27, (Ii) 1Wg/Mw-07/2026-27, (Iii) 1Wg/Mw-08/2026-27
Basic Detail
Tender No GE(AF)/SGR-71/2026-27
Bidding Type Tender
Location
City Budgam
State Jammu and Kashmir
Key Dates
Publish Date 15 Oct 2026
Submission Date 07 Nov 2026
Open Date 09 Nov 2026
Finance
Tender Value 15.50 Lakhs
Tender Fee 500
EMD 31000
Exemption Not Available
Document List
9f1f9298-4e7b-44d0-bf45-dd64c05ae59e.html
BOQ_890489.xls
Tender71.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Oct 15, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Nov 07, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 22 days
Nov 09, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 24 days

Tender Documents

Download All (ZIP) ↓
html

9f1f9298-4e7b-44d0-bf45-dd64c05ae59e.html

xls

BOQ_890489.xls

pdf

Tender71.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender