Housing Urban and Rular Development Government Departments Closing in 0 days TDR #58053628

Tender For Maintenance & Electrical Consumption Charges Of Street Light On Pwd Road Under C&Nd Division. (Sh: - Providing And Fixing Of Cables, Fittings, Bollard, Panels At Swami Narayan Marg, Sawan Park Under Sub Division M-3513).

Issued by Government Departments · Delhi, Delhi
Tender Value
35.54 Lakhs
Estimated cost
Bid Submission
22 Oct 2026
0 days left
EMD
71088
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Delhi → Delhi
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Maintenance & Electrical Consumption Charges Of Street Light On Pwd Road Under C&Nd Division. (Sh: - Providing And Fixing Of Cables, Fittings, Bollard, Panels At Swami Narayan Marg, Sawan Park Under Sub Division M-3513).

BOQ

Name of Work:- Maintenance & Electrical consumption charges of street light on PWD Road under C&ND Division. (SH: - Providing and fixing of Cables, Fittings, Bollard, Panels at Swami Narayan Marg, Sawan Park under sub division M-3513).
Sl. No. Item Description
1Supplying, Installation, Testing & Commissioning of SMC pole Box of size 250mm x 200mm x 105mm with hinged cover on surface/ recess/pole complete with aluminium connector strip - 2 Nos, MS Clamp - 2 Nos., 6-32amp. C series SPMCB- 1 No., having IP: 66 protection connection etc. as reqd.
2Supplying & laying of following size XLPE insulated and PVC sheathed aluminium conductor armoured power cable of 1.1 KV grade in RCC/DWC Pipe/Open Channel / surface / ground etc as required.
34 x 16 sq.mm
44 x 25 sq.mm
5Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required..
6Supplying and Drawing i/c connections & interconnections of following sizes of PVC Insulated and PVC Round Sheathed Multi Core Flexible Aluminium Conductor Heavy Duty Industrial Cables for Voltage Grade 1100 Volts as per IS: 694:2010 for interconnection from window to fitting of street light pole and high mast pole height of upto 30 mtrs.etc complete as reqd.
73 x 2.5 sq.mm
8Supplying, installation, Testing & Commissioning of Street light LED fixture powder coated pressure die cast aluminium body with driver as per the requirement with Driver efficiency >85%, Input voltage: 140-270 Volt AC, frequency 50/60 hz, Operating temp range -5 0C to 50 0C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2, P. F.≥0.95, IP-66,IK-10, CRI >70, under voltage and over voltage protection, EMIEMC As per CISPR 15 , lenses for beam angle as per IESNA type I/II/III as per the width of the road and the project requirement., suitable to fit in up to 65mm dia pipe, life time (LED, Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Colour Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 <135 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C).
9150 watt
10200 watt
11Supplying, Installation, Testing & Commissioning of Flood Light, powder coated pressure die cast aluminium body with built in or separate driver as per the requirement with Driver efficiency >85%, Input voltage: Input voltage: 140-270 Volt AC, frequency 50/60 hz, Operating temp range -5 0C to 50 0C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2, P. F.≥0.95, IP-66,IK-10, CRI >70, under voltage and over voltage protection, EMI-EMC as per CISPR-15, lenses for beam angle 30 deg-120deg as per the application and the project requirement, suitable tilt able fitting, life time (LED, Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Colour Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 and <135 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted.. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C).
12250 watt
13Supplying & erection of flange mounted hot dip galvanized octagonal poles of 12 mtrs. height made from 4 mm thick HT steel plate having bottom dia of 200-240 mm & top dia of 90-100 mm complete with window sleeve type cover/door (flush with exterior surface and shall have suitable locking arrangement) at a height of 2.5 mtrs from the base for cable termination block etc. and galvanized base plate of size 320 mm x 320 mm x 20 mm thick complete etc as reqd. Provision should be provided in the bottom compartment to mount PVC/Bakelite sheet along with connectors for cable looping and single pole MCB to isolate individual luminaire i/c disconnections of cable from old poles and connection of existing cable to new poles etc as required.
14Pdg. & making RCC foundation of following size with M.20 grade concrete with foundation bolt set 750 mm x 24 mm dia J-Bolt for reinforcement along with centering & shuttering i/c anchor of size M 16 along with template suitable for 10/12 mtr pole complete with excavation the soil & refilling ramming, curring etc as reqd of size 500mm x 500mm x 1000mm (800 mm below ground level & 200 mm above ground level) (The foundation drawing shall approved by the Engineer-in-charge)
15Supplying & fixing of Galvanized Overhang 1000mm long bracket made from 48.3 OD ERW pipe for street light Octagonal pole of following arms etc. as reqd. The design shall be approved engineer incharge .
16Double Arm
17SITC of Full cast iron pole 4 Mtr (nominal) above the foundationtop level .with D/A Bracket, weight of pole & Bracket approx. 160kg± 3%. Pole made out of cast iron Top to bottom, Base Plate Size 390mm. The Pole & bracket fabricated with cast iron embellishment, joints column section etc including reinforced internally M.S. tube inside the pole. The bottom pole should have an integral inbuilt connection box with cover duly mounting arrangement of one no.10 amp. SPMCB, one No.32 amp 4way heavy duty connector complete etc as reqd. The pole shall be painted by attractive looking paint of gold /copper colour black base as required to give it a rich look. This colour shall be of polyurethane paint & lacquer coating shall make the pole made out of Aluminium die cast housing of IP-65 Fully weather proof, finish with antique colour, Golden colour in casted portion, single piece of lower length, bottom Dia 60 OD and sections of pole & 2 Nos post top fittings of approx size 580 mm x 340 mm with minimum 5000 lumen each and efficacy not less than 100 lumen / watt, highly efficacy electronic external driver, high voltage protection, power LED white / Warm white mounted on MCPCB with better heat dissipation arrangement. Including 3 x 4 Sq.mm Aluminium wire for supply of fitting, duly wired up to connector complete etc as reqd.The bottom column should have an integral inbuilt looping box withcover of the same & with Foundation 600 x 600 x 600mm) i/c nut bolt. Complete etc as reqd.
18Supply of of 600 mm long MS PU painted bollard made out of 150 x 150 x 3 mm thick MS pipe having Lazer cutting design diffused with UV protected polycarbonate sheet, bollard having base plate size 250 x 250 x 6 mm thick. Bollard having inbuilt 2X10W warm white LED light inside operating voltage 150V to 270V, 50Hz AC, including 3 x 4 Sq.mm Aluminium wire for supply of fitting etc & with Foundation 600 x 600 x 600mm) i/c nut bolt. Complete etc as reqd.
19Supplying, installation, Testing & commissioning of 110 Amp. power contractor with connection complete etc. as required.
20Fabrication, supply, installation, testing and commissioning of MV compartmentalized type outdoor type double door cubical feeder pillar panel, having front area not less than 1.6 sqmtr. having 300 mm depth, made out of 2 mm thick CRCA sheet with 300 Amps rated 4 strip aluminium busbar, free standing totally enclosed dust and vermin proof, suitable for operation on 3 phase 415 V, 4 wire AC supply system, having suitable cable entry arrangement with detachable gland plates, duly powder coated, interconnection with suitable size aluminium strips / bars connections, earthing labelling, quarter turn knobs, etc. with cable chamber, busbar chamber conforming to section-4 of CPWD specification for Electrical works part IV Substation 2013 etc., complete with fixing of panel on MS stand of size 50 mm x 50 mm x 6 mm thick and 1000 mm height angle iron framework grouted 500 mm deep in CC foundation i/c painting of MS frame work with synthetic enamel paint etc. as reqd. (a) Incomer = 250A 4P MCCB, 415V, 36 kA (Icu=Ics), with Thermal Magnetic release (b) Metering compartment: Digital Multifunction meter (having basic parameters: Amps, Volts, W/VA, KWh /KVAh ) set of CTs - 1 Set b) Phase indicating lamps(LED type) with toggle switches, control fuses etc. - 1 set (c) Outgoings: ) 250 A Power contactor three pole with 415 volt AC supply - 1 Nos.b)125 A TP MCCB, 415 V, 25 kA (Ics = Icu), with adjustable thermomagnetic release - 3 Nos. c) Digital timer switch capable of automatic switching On & OFF of street lights at sun set & sun rise or twilight (Auto ON, Auto OFF) in feeder pillars / Lighting DBs for three phase supply - 1 No. d) GI earth strip of suitable size to full width of cubicle panel with two earth studs at the ends as required - 1set e) Anodised aluminium MV danger notice plates and phenolic labeling as required - 1set
21Less credit for old dismantled material received from site.
22Assorted size LED Fittings 150/180/200/ 250 watt
23Feeder Pillar Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 58053628
AUTHORITY Government Departments
TENDER VALUE 35.54 Lakhs
LAST DATE 22-10-2026
Authority
Authority Name Public Works Department
Work Description Tender for Maintenance & Electrical Consumption Charges Of Street Light On Pwd Road Under C&Nd Division. (Sh: - Providing And Fixing Of Cables, Fittings, Bollard, Panels At Swami Narayan Marg, Sawan Park Under Sub Division M-3513).
Basic Detail
Tender No 53/2026-27/EMD M-351/EE(E)
Bidding Type Tender
Location
City Delhi
State Delhi
Key Dates
Publish Date 15 Oct 2026
Submission Date 22 Oct 2026
Open Date 22 Oct 2026
Finance
Tender Value 35.54 Lakhs
Tender Fee Ref. Documents
EMD 71088
Exemption Not Available
Document List
53TenderNotice.pdf
676b2798-3636-4701-8df7-b168cddfd334.html
BOQ_400399.xls
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Oct 15, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Oct 22, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Today
Oct 22, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Today

Tender Documents

Download All (ZIP) ↓
pdf

53TenderNotice.pdf

html

676b2798-3636-4701-8df7-b168cddfd334.html

xls

BOQ_400399.xls

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender