Housing Urban and Rular Development Local Bodies Closing in 6 days TDR #58053282

Tender For Construction Of 400 Kld Stp In 432 Ews Buildings Under Pradhan Mantri Awas Yojana And 5 Years Operation And Maintenance Work In Dasna Ghaziabad.

Issued by Local Bodies · Ghaziabad, Uttar Pradesh
Tender Value
1.40 Crore
Estimated cost
Bid Submission
28 Oct 2026
6 days left
EMD
2.80 Lakhs
Bank guarantee accepted
Document Fee
7198
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Ghaziabad → Uttar Pradesh
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Construction Of 400 Kld Stp In 432 Ews Buildings Under Pradhan Mantri Awas Yojana And 5 Years Operation And Maintenance Work In Dasna Ghaziabad.

BOQ

Name of Work:- Construction of 400 KLD STP in 432 EWS buildings under Pradhan Mantri Awas Yojana and 5 Years Operation and Maintenance Work In Dasna Ghaziabad.
Sl. No. Item Description
1Earth work in excavated by mechenical means (hydraulic excavator)/ manual means in foudation trenches or drains (not exceeding 1.5 m in width of 10 sqm on plan), including dressing of sides and ramming of bottoms, for all lift, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil Extra for additional lift of 1.50m DSR2023/2.8.1+2.26.1+3% 0.00 to 1.50m
21.50 to 3.00m
33.00 to 4.50m
44.50 m to 6.00m
56.00 to 7.50m
6Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering all work up to plinth level 1:4:8 (1 cement: 4 coarse sand (Zone-III) derived from natural sources:8 graded stone aggregate 40 mm nominal size derived from natural sources) item no-4.1.8 DSR 2023 +3%
7Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge. (Note:-Cement content considered in this item is @ 330 kg/cum. Excess/ less cement used as per design mix is payable/recoverable separately). DSR 23/5.33.1.1 UP TO PLINTH LEVEL All works upto plinth level DSR 5.33.1/2023+3% Raft
8M.S. steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. mild steel and medium tensile steel bars. Item no-5.22.1 DSR 2023+3%
9Providing and laying water proofing treatment of retaining/underground structure on horizontal & vertical surface by applying cement slurry coating and grouting, consisting of following operatinas (a) Placing & fixing 20mm dia threaded nozzles of suitable length, which shall be provided on a regular interval not exceeding 1.0 Mt. Including the construction jint/cold joint. b) Injection of polymer based grout admixed with cement through nozzles under pressure by pump @200gm per bag of cement.(c) Sealing of nozzles after grouting with polymer products with cement. (d) Providing & laying cement slurry @ 0.375 Kg/Sqm. (e) Second layer cement slurry @ 0.375 Kg/Sqm mixed with acrylic co-polymer @ 0.250 Kg/sqın by brush. (f) Providing and laying 20mm thick cement plaster of 1:4 cement coarse sand mortar and finishing the surface with neat cement admixed with integral water proofing admixture @ 150 mi per bag of cement over on treated surface
10Cement concrete flooring 1:2:4 (1 cement: 2 coarse sand: 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete.40MM Thick with 20mm norminal size stone ageregate DSR2023/11.3.1+3%
1120 mm cement plaster1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement.DSR2023/13.9.2+3%
12Finishing walls with water proofing cement paint of required shade:New work (Two or more coats applied @ 3.84 kg/10 sqm)DSR2023/13.44.1+3%
13Supply and fixing Galvanized corrugated and powder coating iron roofing in position including supply of all materials labour. Tools &plants etc. required for proper completion of the work and including wastage.SI. NO. 536/SOR-2022 0.80mm thick
14Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.DSR2023/10.2+3%
15Factory made 50mmx47 mm with a wall thickness of 5 mm door frame PVC extruded sheet including carriage 13.61.1 Two or more coats on new work DSR-2023/13.61.1+3%
16SEWAGE TREATMENT PLANT:Design, Supplying, Installing, Testing & Commissioning of Sewage Treatment Plant capacity 400 m3/day Nature of effluent Domestic Sewage from Toilet use and kitchen waste Daily average flow-400 Cum/Day pH-7.5-8.5 BOD5-upto 300-350 Mg/L S. Solids-200-250 Mg/L COD-upto 400-500 Mg/L Oil & Grease-30 Mg/L Effluent discharge standard after treatment pH-6.0-8 BOD5-Less than 10 Mg/L S. Solids - Less than 20 Mg/L COD-Less than 50 Mg/L Oil & Grease - Less than 5mg/1 Sewage Treatment Plant shall comprise of following tanks in civil: Bar Screen Chamber - 1 No Oil & Grease Trap Chamber 1 No Equalization Tank - 1 No Irrigation Water Tank - 1 No Flushing Water Tank - 1 No Plant Room-1 NoShop DrawingsDetailed GA drawing, flow diagram, equipment list, power load requirement with design calculations of all Tanks, elements of the plant, electrical and mechanical work to satisfy / supply adequacy of design followed by submission of detailed GOOD FOR CONSTRUCTION' architectural, electrical, mechanical and piping drawing for approval. Contractor shall ensure submission of detailed GA drawings (Plan & Section), P & I diagram, schematic diagram for the above mentioned components and additional components such as inserts, puddle flanges, vent pipes etc. if so required for the complete work
17Electromechanical:Supply, installation, testing & commissioning of 2 Nos Stainless Steel Perforated Screen with suitable lifting arrangement mechanically with bar space 10 mm for coarse screen and bar space 5 mm for fine screen
18Supply, installation, testing & commissioning of float level switch for automatic operation of the system for high/low level control with auxillary NO/NC contacts
19Supply, installation, testing & commissioning of non clogging type pumps, having Cl casing & SS shaft, CI impeller complete with all accessories, motor of required capacity. Delivery header with isolation valve/NRV etc on delivery line with level switch with wiring to control the level of sump automatically. Pump shall have following duty. Solid handling cap. 30-40 mm. Sewage Transfer Equalization Tank Pumps Submersible in Equalization tank Flow rate (each): 17 m3/hr Head: 10 meter 1 Set: 2 Nos. (1 Working +1 Stand By)
20Air diffusion system shall include the following:Supply, fixing, testing & commissioning of 2 Nos. (1 working & 1 standby) Twin Lobe Air Blowers (common for mixing & aeration) capable of delivering system required free air driven through \\"V\\" belt or directly coupled through flexible coupling to a TEFC motor of suitable HP for 415 ± 10% volts, 3 phase, 50 cycles A.hC. supply complete with valves, headers, NRVs, Pressure gauge Base Frame etc. Capacity (each): 450 M³/Hr. at 0.35 to 0.5 kg/cm2 or as per design calculation 1 Set: 2 Nos. (1 Working +1 Stand By)
21Non clog type air dispersion system capable of handling 3-5 cfm of air with oxygen transfer 6 efficiency of 3-4% per/meter water depth. Air dispersion grid shall be assembled in modular form so that they can be replaced / repaired Coarse Bubble Tubular Diffusers for Equalization Collection Tank Coarse Bubble Tubular Diffusers for Sludge Holding Tank Fine Bubble Tubular Diffusers for Aeration Tank
22Supply of PP hybrid fluidised MBBR media for aeration tank having surface area of 400 m2/m3 and media loading rate of 16 grams BOD/m2.
23Supply, Installation, testing and commissioning of PVC tube settling media having plain settling area of 11 m2/m3 to be installed in Settling Tank. Frame work for media in MS along and any other civil work will be in scope of civil contractor.
24Supplying, installing, testing & commissioning of centrifugal filter feed water pumps SS 304 Casing, SS 304 Impeller, SS 304 Shaft with mechanical seal along with motor. Pressure gauge with isolation cock, NRV, Isolation valve on delivery line and Isolation valve, stainer at suction. The pump shall be suitable for 415 ± 10% volts, 3 phase, 50 cycles a/c supply Filter Feed Pumps Flow rate: 5.0 M3/hr. Head: 30-35 mtr 1 Set: 2 Nos. (1 Working +1 Stand By)
25Supplying, installing, testing and commissioning of Composite MSEP Filter Vessel with 6 mm shell thickness and 8 mm dish end thickness, internal distribution system, MS C Class frontal piping, manual valves, first fill media, pressure gauge etc complete to give filtered treated water. Multigrade pressure sand filter media Flow rate: 17 M3/hr. Filteration velocity: 15 cum/hr/sqm Filter Size: 1200 mm diameter, 1800 mm Height
26Activated Carbon Filter Flow rate: 17 M3/hr. Filteration velocity: 15 cum/hr/sqm Filter Size: 1200 mm diameter, 1800 mm Height
27Supply, installation, testing & commissioning of Chemical Dosing System (disinfection / cleaning) 11 comprising 0-6 LPH electronic diaphragm type metering pump along with 100 Itrs LDPE/HDPE tank with inlet and outlet connection.
28Supply, Installation, testing & commissioning of LLDPE/HDPE CIP Tank of 500 Itrs capacity complete with inlet, outlet connection, float switch and automation valve.
29Flushing water Transfer water Flow Rate:9.0m3/Hr(Each) Head: 60meter 1set:2 No (1 Working+1stand By)
30Irrigation Water Transfer Flow Rate: 6 m3/hr each Head: 40 meter 1 Set: 2 No (1 Working + 1 Stand By)
31Supplying, installing, testing & commissioning of self priming sludge recirculation pumps C Casing, Cl Impeller, CS Shaft with mechanical seal along with motor, isolation cock, NRV, Isolation valve on delivery line. The pump shall be suitable for 415 ± 10% volts, 3 phase, 50 cycles a/c supply Flow rate: 7.5 M3/hr Head: 8 mtr 1 Set: 2 Nos. (1 Working +1 Stand By)
32Filter Pree Feed Pump Flow Rate: 6 m3/hr each Head: 40 meter 1 Set: 2 No (1 Working + 1 Stand By)
33Filter Press Flow Rate: 6 m3/hr each
34MBBR Tank -2, Tube Settler-1, CCT-1, SHT-1 MSFRP-5 mm Please Enable Macros to View BoQ information
35MBBR Tank -2, Tube Settler-1, CCT-1, SHT-1 MSFRP-5 mm Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 58053282
AUTHORITY Local Bodies
TENDER VALUE 1.40 Crore
LAST DATE 28-10-2026
Authority
Authority Name Ghaziabad Development Authority
Work Description Tender for Construction Of 400 Kld Stp In 432 Ews Buildings Under Pradhan Mantri Awas Yojana And 5 Years Operation And Maintenance Work In Dasna Ghaziabad.
Basic Detail
Tender No 696/4/PA-T/2026-27 Dt. 13.10.2026 (S.no-9)
Bidding Type Tender
Location
City Ghaziabad
State Uttar Pradesh
Key Dates
Publish Date 15 Oct 2026
Submission Date 28 Oct 2026
Open Date 30 Oct 2026
Finance
Tender Value 1.40 Crore
Tender Fee 7198
EMD 2.80 Lakhs
Exemption Not Available
Document List
696_9.pdf
a35b6e62-186e-4c8e-aef6-167c8a0fb030.html
BOQ_2261508.xls
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Oct 15, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Oct 28, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 6 days
Oct 30, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 8 days

Tender Documents

Download All (ZIP) ↓
pdf

696_9.pdf

html

a35b6e62-186e-4c8e-aef6-167c8a0fb030.html

xls

BOQ_2261508.xls

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender