Tender For In Gomti Nagar Vistaar Yojana, Construction Of 400 Kl Sump Pumping Station For Drainage Of Rain Water Underpass In Front Of Janeshwar Mishra Park Gate No. 2 And The Annual Maintenance And Operation Work For 05 Years.
Tender Overview
Project Description
Tender for In Gomti Nagar Vistaar Yojana, Construction Of 400 Kl Sump Pumping Station For Drainage Of Rain Water Underpass In Front Of Janeshwar Mishra Park Gate No. 2 And The Annual Maintenance And Operation Work For 05 Years.
BOQ
| Sl. No. | Item Description |
| 1 | Earth work in excavation by mechanical means (Hydraulic excavator) manual means over areas (exceeding 30cm in depth. 1 5m in width as well as 10 sqm on plan) including disposal of excavated carth, lead upto Som and lift upto 1.5m, disposed earth to be levelled and neatly dressed. (Analysis Rate) 0.0 to 1.50 Mtr |
| 2 | Earth work in excavation by mechanical means (Hydraulic excavator) manual means over areas (exceeding 30cm in depth. 1 5m in width as well as 10 sqm on plan) including disposal of excavated carth, lead upto Som and lift upto 1.5m, disposed earth to be levelled and neatly dressed. (Analysis Rate) 1.50 to 3.0 Mtr |
| 3 | Earth work in excavation by mechanical means (Hydraulic excavator) manual means over areas (exceeding 30cm in depth. 1 5m in width as well as 10 sqm on plan) including disposal of excavated carth, lead upto Som and lift upto 1.5m, disposed earth to be levelled and neatly dressed. (Analysis Rate) 3.0 to 4.50 |
| 4 | Earth work in excavation by mechanical means (Hydraulic excavator) manual means over areas (exceeding 30cm in depth. 1 5m in width as well as 10 sqm on plan) including disposal of excavated carth, lead upto Som and lift upto 1.5m, disposed earth to be levelled and neatly dressed. (Analysis Rate) 4.50 to 6.0 Mtr |
| 5 | Supply, Transportation by mechanical means and spreading , levelling and compaction of Earth inside Campus lead upto 15 km distance |
| 6 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in :, Cement mortar 1:6 (1 cement : 6 coarse sand) |
| 7 | Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level., Cement mortar 1:4 (1 cement :4 coarse sand) |
| 8 | Providing and laying Non Pressure NP-3 class (Medium duty) R.C.C. pipes including collars/ spigot jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete, 450 mm dia RCC pipes. |
| 9 | Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approved steel primer., Providing & Fixing of Door/ Windows Grill |
| 10 | Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required., In gratings , frames, guard bar , ladder, railings , brackets , gates and similar works |
| 11 | Providing and fixing angle iron frames for doors, windows and ventilators of mild steel Angle sections of size 35x35x5 mm, joints mitred and welded by angle iron 35x35x5 mm or 35x 5 mm flat pieces to the existing T-iron frame or to the wall with dash fastener, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer, all complete as per the direction of Engineer-In-charge |
| 12 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :, 1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources). |
| 13 | Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete. Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement, All works above plinth level upto floor V level, Concrete of M30 grade with minimum cement content of 350 kg /cum |
| 14 | Centering and shuttering including strutting, propping etc. and removal of form for :, Suspended floors, roofs, landings, balconies and access platform |
| 15 | Centering and shuttering including strutting, propping etc. and removal of form for :, Lintels, beams, plinth beams, girders, bressumers and cantilevers |
| 16 | Centering and shuttering including strutting, propping etc. and removal of form for :, Columns, Pillars, Piers, Abutments, Posts and Struts |
| 17 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level., P/F Mild steel or iron in plain work such as reinforced concrete or reinforced, brick work (when not included in over all rates) wrought to required shape as necessary including bending for proper completion of the work and including supply of all steel and and over lapping & hooks. DSR 20235.22A.6 |
| 18 | 12 mm cement plaster of mix :, 1:6 (1 cement: 6 fine sand) |
| 19 | Cement plaster 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement., 20 mm cement plaster |
| 20 | Wall painting with acrylic emulsion paint, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre, of approved brand and manufacture, including applying additional coats wherever required, to achieve even shade and colour., Distempering (Two coat) with oil bound distemper of approved brand and manufacture & of required shade on undecorated wall surface to give an even shade over & including a priming coat with cement primer of approved brand & manufacture such as Berger, J&N, Shalimar, Asian paints after thoroughly brushing the surface free from mortar droppings & other foreign matters & also including preparing the surface even with plaster of paris or approved synthetic material & sand papered smooth including cost ofall materials. (For Internal wall surface) |
| 21 | Finishing walls with water proofing cement paint of required shade :, Finishing walls with water-proofing on cement paint of approved make such as super snowcem. durrocem, robiacem, guttucem, supercem quality and of required shade on undecorated wall surfaces (two coat) overone and including one coat white cement primer to give an even shade after thoroughly brushing the surface to powdered materials including curing and cost of all materials |
| 22 | Providing and fixing ISI marked oxidised M.S. tower bolt black finish, (Barrel type) with necessary screws etc. complete (Copper oxidised as per IS 1378), 250x10 mm |
| 23 | Providing and fixing ISI marked oxidised M.S. tower bolt black finish, (Barrel type) with necessary screws etc. complete (Copper oxidised as per IS 1378), 200x10 mm |
| 24 | Providing and fixing ISI marked oxidised M.S. handles conforming to IS:4992 with necessary screws etc. complete (Copper oxidised as per IS 1378), 125 mm |
| 25 | Painting on G.S. sheet with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :, Painting two coat over priming coat (but including cost of priming coat) on steel and other metal surfaces up to 10 cm. width or girth or small acies not exceeding 0.10sqm in area white superior synthetic enamel such as LUXOL3 Hi-gloss apcolite superla:, DULUX specified brushing to give an even shade and including cleaning the surface of all dirt dust and other foreign maiter sand papering and stoping including cost of all itaterials labour tools and plants etc required for proper 2 completion of the work |
| 26 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :, same as item 21 above but on new wood surface |
| 27 | Supply, Installation Testing & Commissioning of Electric sewage VT Propeller Axial Flow Pumping plant including level sensor for auto operation, column assembly ,Suction Stainer. Tee ,Reducer, coupling with all connected Equipment etc all Complete (Kirloskar, Flowmore or Equivalent Make, relevant to IS/B3 Standard )13000 LPM capacity ,12 M head , complete in all respect. Pumpset Data Sheets Liquid - Storm Water/Flood Water Sp. Gravity - 1.10 Pump Capacity - 13000 lpm Pump Size - 12'' Pump Speed - 1500 RPM Dischage - 780 m3 Bowl eff. - 82% Lubrication - water Motor Rating - 45 KW Speed - 1500 RPM Make - ABB Voltage - 415 frq - 50 Hz. T & P - vertical - Solid shaf-1 Load Detail Pump - 2000 KG (Approx) Motor - 400 KG (Approx) Details of discharge flange as per IS - 1538 (300 NB) MOC: Casing :1.5-2% NiCI FG 260 Impeller :CF8M OR latest advance material, line-impeller Shaft/coupling-SS410, Col. pipe, dischare hood: MS |
| 28 | Supply, Installation Testing & Commissioning of LT Starter Panel (mains and stater ) suitable for above Pump with required Civil work and Complete in all respect. Supply of LT panel with Two incoming ( 1 CSS +1 DG set) , AMP panel, APFC panel , Phase reversal and all safety measeres and 3 outgoing for pump, EOT crane, light & fan, for spare of PPT, Suitable capacity of Fully Automatic Star Delta Starter of MAKE ABB/ L&T/ Eqv. , comprising with following item as per given below. l. Contactor of suitable ratings. m. TOR of Suitable ratings. n. PB Switches o. Dual Amp & Voltmeter p. Amp meter Selector Switch q. Toggle Switches r. Indicating Lamps Phase Failure s. Phase reversal relay t. Single phase preventer u. Capacitor of suitable ratings. v. GSM |
| 29 | Supply, Installation Testing & Commissioning of NR Valve special design for sewage purpose. Flanged end as per IS : 5312 Body, Cover-CI IS : 210, Gr. FG260 Door-CI IS : 210 Gr. FG260 Body Ring - bronze IS : 318 Gr. LTB2 Door Face - Natural Rubber Hinge Pin - SS ASTM A276 Type 410 Fasteners - CS IS : 1367, CL - 4.6/4.0 Gasket-Natural Rubber Flange Drilling - IS : 1538, Table 4 & 6 300 mm dia. |
| 30 | Supply, Installation Testing & Commissioning of NR Valve special design for sewage purpose. Flanged end as per IS : 5312 Body, Cover-CI IS : 210, Gr. FG260 Door-CI IS : 210 Gr. FG260 Body Ring - bronze IS : 318 Gr. LTB2 Door Face - Natural Rubber Hinge Pin - SS ASTM A276 Type 410 Fasteners - CS IS : 1367, CL - 4.6/4.0 Gasket-Natural Rubber Flange Drilling - IS : 1538, Table 4 & 6 600 mm dia |
| 31 | Supply, Installation Testing & Commissioning of Cast Iron Rising Spindle Sluice Valve Flanged end as per IS : 14846 Body, Cover - CI IS : 210, Gr. FG260 Door-CI IS:210, Gr. FG260 Body Ring-Bronze IS : 318 Gr. LTB2 Door Face-Natural Rubber Hinge Pin - SS ASTM A276 type 410 Fasteners - CS IS : 1367, CL -4.6/4.0 Gasket-Natural Rubber Flange Drilling - IS : 1538, Table 4 & 6 300 mm dia. |
| 32 | Supply, Installation Testing & Commissioning of Cast Iron Rising Spindle Sluice Valve Flanged end as per IS : 14846 Body, Cover - CI IS : 210, Gr. FG260 Door-CI IS:210, Gr. FG260 Body Ring-Bronze IS : 318 Gr. LTB2 Door Face-Natural Rubber Hinge Pin - SS ASTM A276 type 410 Fasteners - CS IS : 1367, CL -4.6/4.0 Gasket-Natural Rubber Flange Drilling - IS : 1538, Table 4 & 6 600 mm dia. |
| 33 | Safe Working Load (SWL) 5 Ton Type Hand Operated Overhead Travelling Crane Girder Single Girder Hoist Manual Chain Pulley Block with Geared Trolley Hoist Travel Hand Chain Operated Cross Travel (CT) Manual Long Travel (LT) Manual Chain Drive Span As per building (typically 6-12 m) Lift Height 3-12 m (customizable) Duty Class Class 1/ Light Duty (Maintenance) Power Supply Not required (fully manual) Design Standard IS 807, IS 3177 and applicable Indian Standards Factor of Safety As per IS standards Finish Red oxide primer + enamel paint or epoxy paint Testing 125% overload test before commissioning Main Components 1. Single Girder Bridge, End Carriages 2. Manual Long Travel Mechanism 3. Manual Geared Trolley 4. 5 Ton Chain Pulley Block 5. Wheels with Bearings, 6. Buffers 7. End Stops, 8. Hand Chain Assembly |
| 34 | Supply, Installation Testing & Commissioning. 300 mm Dia MS rising mains of 6.0 mm wall thickness including coupling and laying for discharge of the storm of the pumping plant including excavation laying of the pipe etc. 1.0 to 1.50 Mtr. deep into the underground trench excavated in the existing road etc all comp. as per direction of E/inch. as per the unit rate analysis. |
| 35 | Supply, Installation Testing & Commissioning. 600 mm Dia MS rising mains of 6.0 mm wall thickness including coupling and laying for discharge of the storm of the pumping plant including excavation laying of the pipe etc. 1.0 to 1.50 Mtr. Deep into the underground trench excavated in the existing road etc all comp.with required civil work and complete in all respect |
| 36 | Supply, Installation Testing & Commissioning of 400 KVA DG Set , Alternator Water Cooled with Standard Panel, Acoustic Enclosure and Base Frame with required civil work and complete in all respect complying latest Central pollution Control Board Guidlines (CPCB-IV) MAKE KIRLOSKER/STERLING/MAHINDRA/EQV. |
| 37 | Supply, Installation, Testing & Commissioning of MS Work Specify as per site requirment. |
| 38 | Supply and laying of aluminium conductor PVC insulated armoured served sheathed cables 1100 Volts grade at a depth of 750 mm below ground level over a cushion of 75 mm. thick sand all around and protected with burnt bricks on sides and on top. On surface the cable run shall be fixed on M.S. clamps etc. of suitable size or as directed by the Engineer-Incharge, complete in all respect. The armouring of the cable shall be properly connected with the earth conductor by clamps etc., 240 sq. mm 3-1/2 core |
| 39 | Supply and laying of aluminium conductor PVC insulated armoured served sheathed cables 1100 Volts grade at a depth of 750 mm below ground level over a cushion of 75 mm. thick sand all around and protected with burnt bricks on sides and on top. On surface the cable run shall be fixed on M.S. clamps etc. of suitable size or as directed by the Engineer-Incharge, complete in all respect. The armouring of the cable shall be properly connected with the earth conductor by clamps etc., 120 sq. mm 3-1/2 core |
| 40 | ENCAPSULATED PIPE - IN- PIPE EARTHING Supply and burring of Safe Earthing Electrode T-39 Cu Copper Coated, Length up to 3000mm, outer pipe 76.3mm x 3.2 inner pipe 42.4mm x 2.6mm, terminal Dia 12mm, coating 80-100 micron filled with crystalline conductive mixture (CCM) having anti corrosive & conductive property with 50 kgs activated soil (BFC) capable of reducing the soil resistivity with good mixture of retaining capacity along with 30 cm square C.I. frame with hinged cover & masonry housing. (From electrode terminal to switch board, cost of 25 x 3 Copper Strip will be extra). Make: As approved in U.P. P.W.D., & C.P.R.I. Certified. |
| 41 | Supply and Laying of 80 mm dia G.I. pipe for the purpose of cable on the run pole through this G.I. pipe from level as cable carrier pipe should be tied with 2Nos. 50x6mm flat iron clamp with pole as per direction of E/I |
| 42 | supplying and making 185 sqmm 3 Core outdoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required all complite as per direction of E/Ic. |
| 43 | G.I OCTAGONAL POLE Supply & fixing of 9 mtr GI Octagonal Pole of approved make (top dia 70mm, Bottom dia 155 mm and base plate 12mm thik) having 3mm thikness with single arm bracket (1 Mtr length) on RCC foundation including the cost of foundation, foun |
| 44 | S/F of LED Street Light Fitting with mandatory driver set having die cast aluminium body and lenses suitable for 140 to 150 watt. Confirming to IP 66 protection having company LOGO engraved complete in all respect including labour as per direction of E/I. SI. No. 1425/2018 Cat-AAA. 15400-16500 system lumens High Power LED with Lenses, >1101m/W, PF70, Potted driver set (Not Circuitory) Phase to Phase Protection at 440V & > 300V auto cut and re-start feature, with 5 years warrantee. Proper completion of work as per direction of E/I - CAT-AAA |
| 45 | Supply and Installation of 1KW Mud pump in Sump well for cleaning of sunken part of sump after rainy season, including Piping, fitting and panel |
| 46 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable Gl box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required., Group C |
| 47 | Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit along with 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. |
| 48 | Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required., 2X1.5 sq. mm + 1 X 1.5 sq. mm earth wire |
| 49 | Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. |
| 50 | Supplying and fixing suitable size Gl box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required. |
| 51 | Supplying and fixing brass batten/ angle holder including connection etc. as required. |
| 52 | Installation .Testing, Commissioning of wall bracket /ceiling fittings of all sizes and shapes containing up to two GLS/CFL/LED lamps per fitting, complete with all accessories including connections etc. as required. |
| 53 | Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point (without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required., Group C |
| 54 | Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/lsolator), 4 way (4 + 12), Double door |
| 55 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required., Single pole |
| 56 | Supplying and fixing 40/63A rating, 415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of Four poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Similar to Legrand DX3 AC MCBs or equivalent. |
| 57 | Supply of 12W Extruded aluminium batten available in 2ft run length with multiple lumen packages and suitable for surface, wall & conduit ounting (with accessories) similar to Philips Type HSN Code MRP (INR) BN 021 LED125 6500 PSU GR or equivalent MR (RA-3) |
| 58 | Supply of 22W Extruded aluminium batten available in 4ft run length with multiple lumen packages and suitable for surface, wall & conduit conting (with accessories) similar to Philips Type HSN Code MRP (INR) BN 021 LED225 6500 PSU GR or equivalent MR (RA-4) |
| 59 | CEILING FANS Supply of Ceiling Fans with fan motor of A.C Permanent insulation, capacitor rating conforming BEE 5 Star rating and IS:374/79 and also comply with IS:1709/1984 with latest amendment. The rated voltage 220/240 volts, 50Hz, 1-ph AC. The fan assembly should consist of down rod blades, shackle canopies etc and with double ball bearing system., BEE 5 Star rated - 1200mm sweep |
| 60 | Supply of plastic body ventilation fan, 250mm sweep continuously rated highly efficient similar to Crompton Cat. Efficio or equivalent MR (RA-6) |
| 61 | Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings andfixtures complete, including cutting and making good the walls and floors wherever required :, W.C. pan with ISI marked white solid plastic seat and lid |
| 62 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require:, White Vitreous China Flat back wash basin size 550x 400 mm with single 15 mm C.P. brass pillar tap |
| 63 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. |
| 64 | Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931:, 15 mm nominal bore. |
| 65 | Providing and fixing C. brass angle valve for basin mixer and geyser points of approved quality conforming to IS :8931. 15mm nominal bore |
| 66 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes., 110 mm diameter |
| 67 | Providing and fixing on wall face unplasticised - PVC moulded fittings/accessories for unplasticised Rigid PVC rain water pipes conforming to IS 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion., Coupler, 110mm |
| 68 | Providing and fixing on wall face unplasticised - PVC moulded fittings/accessories for unplasticised Rigid PVC rain water pipes conforming to IS 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion., Shoe (Plain), 110 mm Shoe |
| 69 | Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete., 110 mm |
| 70 | External W/s arrangements with T.W. Boring of 150 mm dia with 110 mm dia P.V.C pipe assembly, 5.00 H. submersible pump-K.S.B. make Submersible pumpset 5.0 H.P. discharge 600 LPM. |
| 71 | External W/s arrangements with T.W. Boring of 150 mm dia with 110 mm dia P.V.C pipe assembly, 5.00 H. submersible pump-Control panel board with starter 32 amp. Main switch kit-kat Etc. |
| 72 | External Wis arrangements with TW. Boring of 150 mm dia with 110 mm dia P.V.C. pipe assembly, 5.00 H. submersible pump-80 mm dia M.S. Column Pipe \\"C\\" Class (3.0m) |
| 73 | External W/s arrangements with TW. Boring of 150 mm dia with 110 mm dia P.V.C. pipe assembly, 5.00 H. submersible pump -80 mm dia M.S. Column Pipe \\"C\\" Class (1.5m) |
| 74 | External Wis arrangements with T.W. Boring of 150 mm dia with 110 mm dia P.V.C pipe assembly, 5.00 H.. submersible pump - 80 mm dia MS. Column Pipe \\"C\\" Class (1.0m) |
| 75 | External W/s arrangements with T.W. Boring of 150 mm dia with 110 mm dia P.V.C pipe assembly, 5.00 H. submersible pump -80 mm dia CI. D/F Sluice valve LS.I |
| 76 | External W/s arrangements with T.W. Boring of 150 mm dia with 110 mm dia P.V.C pipe assembly, 5.00 H.. submersible pump -80 mm dia C.L. D/F N.R.V. LS.I |
| 77 | External W/s arrangements with T.W. Boring of 150 mm dia with 110 mm dia P.V.C pipe assembly, 5.00 H. submersible pump 80 mm dia CI. D/F Band |
| 78 | External Wis arrangements with TW. Boring of 150 mm dia with 110 mm dia P.V.C pipe assembly, 5.00 H. submersible pump-80 mm dia M.S. Clamp |
| 79 | External Wis arrangements with T.W. Boring of 150 mm dia with 110 mm dia P.V.C pipe assembly, 5.00 H.. submersible pump - 80 mm dia Rubber Packing |
| 80 | External W/s arrangements with T.W. Boring of 150 mm dia with 110 mm dia P.V.C pipe assembly, 5.00 H.. submersible pump Flat copper Cable 1x3x6.00 mm2 |
| 81 | External W/s arrangements with T.W. Boring of 150 mm dia with 110 mm dia P.V.C. pipe assembly, 5.00 H. submersible pump Nut, Bolt, Washer |
| 82 | External Wis arrangements with T.W. Boring of 150 mm dia with 110 mm dia P.V.C. pipe assembly, 5.00 H.. submersible pump-Motor safety clamp |
| 83 | External W/s arrangements with T.W. Boring of 150 mm dia with 110 mm dia P.V.C. pipe assembly, 5.00 H. submersible pump-Cartage up down |
| 84 | External Wis arrangements with T.W. Boring of 150 mm dia with 110 mm dia P.V.C pipe assembly, 5.00 H. submersible pump-Pump Guard |
| 85 | External W/s arrangements with T.W. Boring of 150 mm dia with 110 mm dia P.V.C pipe assembly, 5.00 H. submersible pump-Installation of Pump-set |
| 86 | 1st year O&M 0.5% FPS (63658773.57) |
| 87 | 2nd year O&M 1% FPS (63658773.57) |
| 88 | 3rd year O&M 1.25 % FPS (63658773.57) |
| 89 | 4th year Operation 1.5 % (63658773.57) |
| 90 | 5th year Operation 2 % (63658773.57) |
| 91 | Boring with hydraulic piling rigs with power units, Providing and installing cast in situ single under reamed piles of specified diameter and length below pile cap in M-25 cement concrete, to carry a safe working load not less than specified, excluding the cost of steel reinforcement but including the cost of boring with bentonite solution and the length of the pile to be embedded in pile cap etc. all complete. (Length of pile for payment shall be measured upto the bottom of pile cap):, 300 mm dia piles |
| 92 | Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters:, Supply & fixing of flush doors commercial quality conforming to IS 2202 Part I (1983) including fixing of wooden cleats and stoppers and including fixing and adjustment of hinges bolts locks handles springs fitting with necessary screws to be supplied departmentally (a) 30mm thick |
| 93 | Providing and laying Ceramic glazed floor tiles of size 300x300 mm(thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement :4 Coarse sand), jointing with grey cement slurry @ 3.3kg/sqm including pointing the joints with white cement and matching pigment etc.,., complete. |
| 94 | Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete., Cement concrete flooring 1 cement 2 coarse sand 4 graded. one aggregate) finished with a floating coat of neat cement, including cenen siurry, but excluding the cost of nosing of steps etc complete) mun thick with 20 mm nominal size stone. |
| 95 | Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) :, Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) |
| 96 | Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations: (a) Applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300 mm height including cleaning the surface before treatment. (b) Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement :5 coarse sand ) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs. (c) After two days of proper curing applying a second coat of cement slurry using 2.75 kg/ sqm of cement admixed with water proofing compound conforming to IS : 2645 and approved by Engineerin- charge. (d) Finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 (1 cement :4 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineerin- charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300 mm square 3 mm deep. (e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test.“All above operations to be done in order and as directed and specified by the Engineer-in-Charge :, With average thickness of 120 mm and minimum thickness at khurra as 65 mm. |
| 97 | Providing and laying water proofing treatment to vertical and horizontal surfaces of depressed portions of WC. kitchen and the like consisting of 1) Ist course of applying cement slurry 4, 4.4 Kg/sqm mixed with water proofing compound conforming to IS 2645 in recommended proportions including rounding off junction of vertical and horizontal surface) IInd course of 20mm cement plaster 13 (1 cement 3 coarse sand) maxed with water proofing compound in recommended proportion mcluding rounding off junction of vertical and horizontal surface IIIrd course of applying blown or residual bitumen applied hot at 17 Kg per sqm of area iv) IVth course of 400 micron thick PVC sheet (Overlaps at jomts of PVC sheet should be 100 mm wide and pasted to cach other with bitumen 17 Kg/sqm) |
| 98 | Providing and mixing integral crystalline admixture for waterproofing treatment to RCC structures like basement raft, retaining walls, reservior, sewage & water treatment plant, tunnels / subway and bridge deck etc.. at the time of transporting of concrete into the drum of the ready-mix truck , using integral crystalline admixture @0.80% (minimum) to the weight of cement content per cubic meter of concrete) or higher as recommended by the manufacturer’s specification in reinforced cement concrete at site of work. The material shall meet the requirements as specified in ACI-212-3R- 2010 i.e. by reducing permeability of concrete by more than 90%, compared with control concrete as per DIN 1048 and resistant to 16 bar hydrostatic pressure. The crystalline admixture shall be capable of self-healing of cracks up to a width of 0.50mm. The work shall be carried out all complete as per specification and the direction of the Engineer-in-charge. The product performance shall carry guarantee for 10 years against any leakage. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 10 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 11 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender