Tender For Construction Of School Building For Boys Middle School Naibasti[Adv. Cost ₹ 137.76 Lacs (₹ 116.75 Lacs Exclusive Of Gst + Gst@18% ₹ 21.01 Lacs)]
Tender Value
Ref. Documents
Estimated cost
Bid Submission
22 Oct 2026
4 days left
EMD
2.75 Lakhs
Bank guarantee accepted
Document Fee
2600
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Anantnag → Jammu and Kashmir
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Construction Of School Building For Boys Middle School Naibasti[Adv. Cost ₹ 137.76 Lacs (₹ 116.75 Lacs Exclusive Of Gst + Gst@18% ₹ 21.01 Lacs)]
BOQ
| Sl. No. | Item Description |
| 1 | Civil Work |
| 2 | Earth work in bulk excavation by Mechanical means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 m2 on plan) including disposal of excavated earthlead upto 50 meters and lift upto 1.5 m, as directed by Engineer-in-Charge. All kinds of soil : |
| 3 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead upto 50 m and lift upto 1.5 m. |
| 4 | Supplying and laying of quarry stone soling hand packed tightly incl ramming watering and filling of interstices incl all carriage complete job excluding the filling availabe at sight |
| 5 | Providing and laying in position cement concrete of specified grade excluding the cost of centring and shuttering- All work upto plinth level. 1:4:8 (1 cement: 4 coarse sand: 8 graded stone aggregate 40mm nominal size) incl all carriage complete job |
| 6 | Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with:1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) including carriage of materials |
| 7 | Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-incharge. Note: - Cement in this item is @ 330 kg/ cum. Excess or less cement used as per design mix is content considered payable or recoverable separately. All works UPTO plinth level . |
| 8 | Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-incharge. Note: - Cement in this item is @ 330 kg/ cum. Excess or less cement used as per design mix is content considered payable or recoverable separately. All works above plinth level upto floor 5 level. |
| 9 | Steel reinforcement for R.C.C. work including straightening, cutting. bending, placing in position and binding all complete above plinth level TMT steel bar |
| 10 | Centering and shuttering including strutting, propping etc. and removal of form for Foundations, footings, bases of columns etc. |
| 11 | Foundations, footings, bases of columns etc. for mass concrete |
| 12 | Columns, pillars, piers, abutments, posts and struts |
| 13 | Lintel, beams, plinth beams, girders, bressumers and cantilevers |
| 14 | Suspended floors, roofs, landings, balconies and access platforms |
| 15 | Stairs (excluding landings) except spiral staircases. |
| 16 | Brick work with common burnt clay (non-modular) bricks of class designation 7.5 in foundation, plinth And super structure including curing in :Cement mortar 1:4 ( 1 cemen: 4 coarse sand) incl carriage |
| 17 | Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia and length (hold fast lugs or with dash fasteners shall be paid for separately): IMPORTED GERMAN KD |
| 18 | Providing and fixing factory made flush door shutters 30 mm thick made of pre-laminated flat pressed three layer particle board conforming to IS: 12823 exterior grade (Grade I Type II) having one side decorative lamination ofapproved shade and other side balancing lamination including second class teak wood lipping of 25mm widex12mm thick with necessary screws and black enameled M.S. butt hinges complete as per directions of Engineer- in-charge |
| 19 | Providing and fixing glazed shutters for doors, windows and clerestory windows using 4mm thick float glass panes including ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws.Foreign wood |
| 20 | Providing and fixing wire gauze shutters using galvanized M.S. wire gauze of average width for aperture 1.4 mm in both directions with wire of dia. 0.63 mm for doors, windows and clerestory windows with ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws as per direction of Engineer-in-charge : Foreign wood |
| 21 | Providing/Fixing glass panes 10kg/sqm (4mm thick)10 kg/ sqm in doors windows and clerestory window shutters (Area of opening for glass panes excld portion inside shall be measured) |
| 22 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade.Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture incl priming coat |
| 23 | Finishing walls with textured exterior paint of required shade on New work (two or more coats applied @ 3.28 liter/10sqm) over and includingbase coat of exterior primer applied @ 2.20kg/10sqm |
| 24 | Providind and fixing of following hardware items of superior quality of Almunium made of Approved Brands as per direction of Engineer-in-charge |
| 25 | Tower Blts 4\\" |
| 26 | Hinges 4\\" |
| 27 | Wind Stopper |
| 28 | Handles 4\\" |
| 29 | Tower Bolts 8\\" |
| 30 | Hinges 6\\" |
| 31 | L drop with inbluit lock |
| 32 | L drop |
| 33 | Handles 8\\" |
| 34 | Providing and laying vitrified floor tiles having antiskid texture in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622 of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1cement :4 coarse sand) including grouting the joints with white cement and matching pigments etc. complete Size of tile 600x600 mm |
| 35 | Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS : 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer- in-Charge, in skirting, risers of steps and dados over 12 mm thick bed of cement mortar 1:3 ( 1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3 kg per sqm, including pointing in white cement mixed with pigment of matching shade complete |
| 36 | 12 mm cement Plaster mix 1:4 ( 1 cement : 4 fine sand |
| 37 | Providing and applying white cement based putty of specified thickness, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.2 mm thick |
| 38 | Providing and applying Plaster of Paris putty of 2mm thickness over plastered surface to prepare the surface even and smooth complete |
| 39 | Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade on New work (two or more coats) over and including priming coat with water thinnable cement primerNote : The Shades recommended to Hospitals should be applied |
| 40 | Structural steel work in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.Welded |
| 41 | Providing & fixing coated galvalume colour hi rib GI sheets 0.50 mm TCT having a erest fasteners height of reputed of 28-32make mm at with 195mm purlins pitch sheet using usingself selfdrilling drillingand andself self tapping tapping fasteners (including cost of all material, leads, lifts and carriages etc upto site of work complete) including Valleys & Ridges with required head load complete. as approved by Engineer-in-charge |
| 42 | Providing and fixing PVC all weather pipe for gutter having dia of 6\\" of prince quality |
| 43 | Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer’s specifications including appropriate priming coat, preparation of surface, etc completeOn steel work |
| 44 | Kota stone slab flooring 25 mm thick over 20mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing, polishing and curing complete with base of cement mortar 1:4 (1 cement : 4 coarse sand) : |
| 45 | Sanitary fittings |
| 46 | Providing and fixing water closet squatting pan (Indian type W.C. pan)with 100 mm sand cast Iron P or S trap, 10 liter low level white P.V.C.flushing cistern, including flush pipe (of approved make) with manuallycontrolled device (handle lever) conforming to IS: 7231, with all fittingsand fixtures complete, including cutting and making good the walls and floors wherever required.White vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests. |
| 47 | SH:II C.P Fitting and Accessories |
| 48 | Providing and fixing 3 layer PP-R (Poly propylene Random copolymer)pipes conforming to IS: 15801, UV stabilized and anti-microbial fusion welded, having thermal stability for hot and cold water supply including all PP-R plain and brass threaded Polypropylene random fittings. This includes testing of joints complete as per direction of Engineer-incharge. |
| 49 | External work including trenching, refilling etc.PN-16 pipe, 32mm OD (SDR-7.4) |
| 50 | Internal work Concealed fixing the pipe with clamps at1.00 meter spacing including cutting breaking anf fixing the pipe with Fittings elbows Tee's Crossovers etc and making good thewall etc.25mm nominal outer dia pipes |
| 51 | Providing and fixing 15 mm nominal bore wash Basin Mixer of approved quality jaquar Hindware Cera conforming to IS : 8931 |
| 52 | Providing and fixing 15 mm nominal boreCP Brass Single lever telephonic wall mixer of approved brand jaquar Hindware Cera conforming to IS : 8931 |
| 53 | 15 mm nominal bore C.P. brass angle valve forof approved approved brand jaquar Hindware Cera conforming to IS : 8931 |
| 54 | Providing and fixing 15 mm nominal bore CPChrome Finish Splash Health Faucet including pipe with Hose & Hook of approved brand jaquar Hindware Cera conforming to IS : 8931 |
| 55 | CP grating rectangular type with Rectangular lid |
| 56 | Providing and fixing PTMT soap dish holder having length of 125mm,breadth 90 mm, height of 70 mm with concealed fitting arrangements,weighing not less than 96gms. |
| 57 | Providing and fixing PTMT Liquid soap container of 350 ml. capacity with concealed fitting arrangements etc complete job |
| 58 | Providing and fixing on wall 50 LTRS ElectricGeyser of approved brand Jaquar Eo Smith Hindware with ABS Body. Equivalent as Per Make List with necessary electric fittings & CPconnections etc all complete |
| 59 | Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backingRectangular shape 1500x450 mm |
| 60 | Providing and fixing toilet paper holder with Flap made out of C.P Brass |
| 61 | Providing and fixing Stainless Steel Retractable Sink Basin Water Drain Pipe of approved quality & make and as per the direction of Engineer-in-charge. (For Kitchen Sink) |
| 62 | Providing and fixing Under Counter wash basin,with 32 mm Waste Coupling and other allied accessories including cutting and making good the walls wherever required:- |
| 63 | Providing and fixing of Ceramic Wallmounted ( 13 * 18 ) Wall Hung Basin (WHITE) |
| 64 | Providing and fixing of water Purifler of 10 Itr storage of approved make provide both hot and cold water etc all including fixing charges and necessary Items required for fixing of water |
| 65 | SH III : SOIL, WASTE AND VENT PIPES |
| 66 | Providing fixing testing & commisioning soil, waste and vent pipes IS 13592 & fittings (IS: 14735 ) suitable to rubber ring joints , which includes bends, T-ee, reducers,rubber ring, jointing, junctions, clean out plug , cowls, offsets, collar, M.S holder-bat clamps, access pieces, (P or S) trap of self cleansing design .etc. complete including jointing.110 mm dia. PVC SWR socketed pipe with rubber ring joints as per IS:13592 Type-B |
| 67 | Providing and Fixing of PVC Floor Traps 110 mm of standard makeand all other fittings required as approved by engineer icharge |
| 68 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank ISI : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank |
| 69 | Providing and fixing PTMT Ball cock of approved quality, colour and make complete with epoxy coated aluminium rod with L.P/H.P.H.D plastic balls.25mm nominal bore, 152mm long, weighing not less than440gms. |
| 70 | P/F in position PVC P or S traps |
| 71 | Providing and fixing uplasticized PVC connection pipe with brass unions. 45 cm long |
| 72 | P/Fixing of Havells ventil air DSP 380 mm Exhaust fan including fixing & dismentalling of wall for the fixing of fan if required etc all complete job |
| 73 | Providing fixing testing & commisioning Crompton of Centrifugal Water Pump (0.5 hp) |
| 74 | P/L. of Nayasa funk square celuxe 3 pcs bathroom set bucket 20 L Mug 1.5L & Stool of approved colour & shade as per the site engineer etc all complete job |
| 75 | Ground development |
| 76 | Earth work in bulk excavation by Mechanical means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 m2 on plan) including disposal of excavated earthlead upto 50 meters and lift upto 1.5 m, as directed by Engineer-in-Charge. All kinds of soil : |
| 77 | Providing and Laying of stone soling, hand packed including carriage of the same from approved source upto site of work complete job. |
| 78 | Providing and laying in position cement concrete of specified grade and raising of lane excluding the cost of centering and shuttering. All work up to plinth level.1:4:8 (1Cement: 4 fine sand: 8 graded stone aggregate 40mm nominal Size), including all carriages. |
| 79 | Providing and laying 60mm thick factory made cement concrete interlocking paver block of M-30 grade made by block making machine with strong vibratory compaction and of approved size and design/shape laid in required colour and pattern over and including 50mm thick compacted bed of fine sand, filling the joints with coarse sand etc. all complete as per direction of Engineer-in-charge. |
| 80 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering. All work up to plinth level.1:2:4 (1Cement: 2 fine sand: 4 graded stone aggregate 20mm nominal Size), including all carriages up to plinth level. |
| 81 | Soakage Pit |
| 82 | Engagement of J CB for surface dressing of road surface, removal of unhygenic material outside site premises, construction of earthern side drain with all leads and lifts and disposal of surplus material outside |
| 83 | Earth work in excavation by manual/mechanical means in foundation trenches, drains, pipes and cables etc. (not exceeding 1.5 Mtr. In width or 10 SqMts on plan) including dressing of sides and ramming of bottoms, lift upt 1.5 Mtr. Including getting out excavated soil and disposal of surplus soil as directed and lead up to 50 Mtrs |
| 84 | Dry random rubble masonry with hard stone in the pit including carriage of same from approved source upto site of work complete |
| 85 | Providing and laying of Reinforced cement concrete 1:1.5:3 grade (1 cement: 1.5 coarse sand: 3graded stone aggregate 20mm nominal size) of specified grade including the cost of centring and shuttering compete job. |
| 86 | Reinforcement for RCC work including straightening, cutting, bending, placing in position etc complete |
| 87 | Centering and shuttering including strutting, propping etc. and removal of form. |
| 88 | Providing and fixing in position polyethylene septic tank type-B (Comfort or equivalent ) having capacity for 20 users, 47\\"x51\\"x119\\" inches in size, including excavation of put as per the size, providing and laying of 150mm thick bed concrete in 1:4:8 mix (1: cement:4 course Sand :8 graded stone agg 20mm nominal size) filling the septic tank with fresh water, connecting the inlet and outlet with the septic tank and filling the dry course of sand and bajre around the septic tank complete Job including carriage of all materials involved |
| 89 | Electric part |
| 90 | Wiring for light point/fan point/exhaust fan point/call bell point with 2 × 1.5 sq.mm PVC insulated, FRLS copper conductor, 1100 V grade wires, complete with all accessories , ( Havell/ Polycab/APAR/ Fenolex/KEI/RR kabel/ Anchor/SSK or eq. single core cable in surface / recessed medium class PVC conduit ( including cost of conduit), with modular switch ( Legrand /SSK /schneider /Crabtree /athena/ABB make.), modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. |
| 91 | Group A |
| 92 | Group c |
| 93 | Wiring for light/ power plug with 2X4 sq. mm + 1X 4 sq. mm earth wire , FRLS PVC insulated copper conductor ( Havell/Polycab/ Fenolex/Anchor/SSK equivalent as directed by engineer incharge.) single core cable in surface/recessed medium class PVC conduit ( including cost of conduit) |
| 94 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, modular plate, suitable GI box , connections etc. as required. ( Legrand /SSK /schneider /Crabtree/ Athena make) |
| 95 | Wiring for lighting circuits/ inverter circuits/ 6- 10 amp power plug with 2X2.5 sq. mm FRLS PVC insulated copper conductor ( Havell/Polycab/APAR/ Fenolex/KEI/RR kabel/ Anchor/SSK make ) single core cable in surface/recessed medium class PVC conduit,( including cost of conduit) alongwith 1 No. 2.5 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. |
| 96 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 2 no. 3 pin 5-10 A modular socket outlet and 2 no. 5-10 A modular switch, connections etc. as required. ( Legrand /SSK / Schneider /Crabtree/ Athena/ABB make.) |
| 97 | Supplying and fixing of following modular switch/ socket/indicator on the existing modular plate and switch box including connections but excluding modular plate etc. as required. i. 3 pin 5/6A socket outlet |
| 98 | Supplying and fixing of following modular switch/ socket/indicator on the existing modular plate and switch box including connections but excluding modular plate etc. as required. i. Indicator |
| 99 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor ( Havell/Polycab/APAR/ Fenolex/KEI/RR kabel/ Anchor make ) as described in item no 1 , single core cable in surface/ recessed medium class PVC conduit as required. Including cost of conduit. |
| 100 | 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire (Inverter Circuit) |
| 101 | 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire (Lighting Circuit) |
| 102 | 2 X 6 sq. mm + 1 X 6 sq. mm earth wire ( Lighting submain) |
| 103 | 2X 10 sq. mm + 1 X 6 sq. mm earth wire ( Heating submain) |
| 104 | S/F testing and comm. Of MCB's 10 kA of the below mentioned capacities in sub main controls legrand C curve ,Schneider / Legrand /ABB, / Havells ,/ Siemens/ L&T / Hager /BCH make OR OEMs/ firms holding ISO 9001 certification (Quality Management System) as directed by engineer in charge. |
| 105 | 6-32 Amp SP MCB |
| 106 | 32 amp DP MCB |
| 107 | 63 amp DP MCB |
| 108 | Supply and fixing modular blanking plates on existing modular switch plates, excluding cost of plates. |
| 109 | Supplying and fixing following way, Horizontal type,Single pole and neutral, sheet steel, MCB distribution board,( legrand/ Shinider/Hager/ABB/SSK/GM make) 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar,din bar, interconnections, powder painted including earthing etc.as required. (But without MCB/RCCB/Isolator) |
| 110 | 4 way(4+12) , Double door |
| 111 | Supply installation testing and commissioning of 10-12 W LED Surface/recess, square or round Mounted light luminary with minimum system lumen efficacy of 100 lm/W . The Input voltage range shall be 150V to 270V .The Fixture should have In-built Surge Protection of 2kV. Certification:- LM79 & LM80 test report should be from govt. approved In-house NABL lab/ government of India. The job includes AMC (reckoned from date of successful commissioning) of lighting fixtures for a period of Two years ,which includes replacement of fixtures also. (Philips/ Havel's /Wipro or eq. make / sample to be approved before installation). |
| 112 | Supply, installation, testing and commissioning of exhaust fan of 200-250 mm sweep suitable for wall/window mounting, complete with necessary frame, mounting arrangement, louvers/shutter, and all accessories as required; the fan shall be of robust construction with high-grade engineering plastic/metal body, aerodynamically designed blades, and heavy-duty copper motor suitable for continuous operation, conforming to relevant Indian Standards and safety requirements of Havell /Bajaj/Crompton/ USHA/Orient OR OEMs/ firms holding ISO 9001 certification (Quality Management System) as directed by engineer incharge as per site requirement and necessary connections. |
| 113 | Supply, Installation, Testing and Commissioning of 1200 mm sweep,, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of Insulation: B, 3 nos. blades, suitable long down rod, 2 no. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.85, Air delivery minimum 215 CMM, 350 RPM (tolerance as per IS: 374- 2019), THD less than 10%, remote regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), Insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required |
| 114 | Supply installation testing and comm. of flood light 50 W ( warm, white ), Epoxy powder coated die-cast aluminum housing (LM24) with elegantly designed heat sink for efficient thermal management, sturdiness & excellent corrosion resistant. PG9 gland is used for cable entry and provision for loopin-loopout class 1, IP66, IK 07, , with high power LED's as light source with Built-In Potted IP67 electronic LED driver with APFC,lower THD, toughned glass and secondary lens,Open Circuit Protection, Over Voltage Protection, Surge Voltage Protection upto 10kV With Built In SPD & other safety test as per IS 15885 Part-2/Sec 13, IEC60598-1. Preferred make: Philips/ Havells /Wipro/Crompton make. the job also includes the angle iron stand of suitable size to be grouted in cement concrete with hold fasteners complete job. |
| 115 | Supply and fixing of 6 amp/250 V AC fan dimmer step type 2 module with cover plate Anchor Roma plus/SSK NV/ equivalent make. |
| 116 | S/Laying (partly overhead/ partly underground), testing and commissioning of XLPE aluminum armoured cable 650 V/1100 V Grade as per IS 7098 (Part 1) 1988 with upto Date Amendments. Havell/Eq. standard make as directed by engineer in charge and making end termination with brass compression gland and aluminum lugs of required size. |
| 117 | 70 sq.mm 2 core (armoured) |
| 118 | Main Panel/ Earthing/ Power Backup/ Air conditions |
| 119 | PANEL: Design, Fabrication, Supplying, Installation, Testing and Commissioning Cft. of following panel, duly manufactured from CPRI approved manufacturer, made out of 2mm thick M.S. sheet steel, floor mounted, vermin and dust proof, outdoor type with suitable size of angle iron legs for grouting in the ground, with lockable type hinged doors, duly painted with provision for fixing of following switch gears,, Aluminum Bus Bar of various ratings after taking Derating factor into account, and other allied accessories etc. as required. The scope of work also entails securely installing the panel into the ground with concrete encasing its legs (As per approved design, size may vary as per site requirement) |
| 120 | INCOMING |
| 121 | 125 amp DP MCB 10 KA Legrand /Schneider/L&T/ABB make. |
| 122 | 4 No. of Aluminum Bus Bar of 200 Amp. |
| 123 | Change over switch 63amp |
| 124 | 2 No. of Aluminum Bus Bar of 200 Amp |
| 125 | Digital meters and phase indicators -1 set. |
| 126 | OUTGOING |
| 127 | 63 amp dp 10KA MCB |
| 128 | 40 amp DP 10KA MCB |
| 129 | Providing of chemical earthing as per IS standards by way of digging 6 feet pit then embedding 2.5 mtr. Long Gi earthing electrode, 60 mm dia. Connecting the electrode with main control board by 10 SWG Copper wire with 1/2\\" dia. Full thread brass nut and bolts and washers, refilling the pit with chemical compound. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Oct 15, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedOct 22, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 4 daysOct 23, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 5 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender