Tender For Repair & Maintenance Of Civil And Electrical Installation Works In Residential Quarters At Pathardih Bphc Under Bagmundih Block In The District Of Purulia.--- Electrical Installation Works.
Tender Value
Ref. Documents
Estimated cost
Bid Submission
31 Oct 2026
13 days left
EMD
48789
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Purulia → West Bengal
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Repair & Maintenance Of Civil And Electrical Installation Works In Residential Quarters At Pathardih Bphc Under Bagmundih Block In The District Of Purulia.--- Electrical Installation Works.
BOQ
| Sl. No. | Item Description |
| 1 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit, with piano type switch, phenolic laminated sheet, suitable size M.S. box and earthing the point with 1.5 sq.mm. FRLS/HFFR PVC insulated copper conductor single core cable etc as required. (Wire Make: Gloster/Polycab/Havells/RR Kable/KEI/Finolex] or make as approved by EIC and Switchs make as approved by EIC) |
| 2 | Group A |
| 3 | Group B |
| 4 | Supplying and fixing metal box of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc as required. |
| 5 | 100 mm X 100 mm X 60 mm deep |
| 6 | 150 mm X 75 mm X 60 mm deep |
| 7 | 200 mm X 150 mm X 60 mm deep |
| 8 | Supplying and fixing following piano type switch/ socket on the existing switch box/ cover including connections etc. as required. (Make as approved by EIC) |
| 9 | 5/6 amps switch |
| 10 | 15/16 amp switch |
| 11 | 3 pin 5/6 amp socket outlet |
| 12 | 6 pin 15/16 amp socket outlet |
| 13 | Supplying and fixing metal box of 150mm X 75mm X 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 3 pin 5/6 amps socket outlet and 5/6 amps piano type switch, connection, painting etc. as required. (For light plugs to be used in non residential buildings). |
| 14 | Supplying and fixing metal box of 180mm X 100mm X 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 6 pin 5/6 & 15/16 amps socket outlet and 15/16 amps piano type switch, connection, painting etc. as required. |
| 15 | Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc as required. |
| 16 | 4 Module (125mmX75mm) |
| 17 | 6 Module (200mmX75mm) |
| 18 | Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required. (Make as approved by EIC) |
| 19 | 4 Module |
| 20 | 6 Module |
| 21 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. (Brand as approved by EIC) |
| 22 | 15/16 amp switch |
| 23 | 6 pin 15/16 amp socket outlet 5, It. No--1.24.5 ] |
| 24 | Supply & Fixing 240 V, 25 A, Modular type starter (Brand approved by EIC) with 25A Modular switch type DP MCB (CCurve) and 4 Module PVC Modular type switch board with 4 Module top cover plate flushed on wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc. |
| 25 | Supply & Fixing 240 V,25 A, 3 pin Modular type plug top with indicator & necy. Connections. (Brand as approved by EIC) |
| 26 | Supplying and fixing Sheet steel Main Switches on flat iron frame on wall - 240V DP with fuse on L&N 30/32 A . [Make- Havells/Lauritz Knudsen (L&T)/ABB/Schneider/Siemens or as approved by EIC ] |
| 27 | Supply & Fixing Single phase Electrical Commercial/Residential 240V 32A Cut Out fuse (Kitkat type)& suitable type encloser with necessary electrical connection as per required etc . [Make- Havells /Lauritz Knudsen (L&T)/ABB/Schneider/Siemens or as approved by EIC ] |
| 28 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) [Make- Legrand/Lauritz Knudsen (L&T)/ABB/Schneider/Siemens or as approved by EIC ] |
| 29 | 2 + 8 way, Double door |
| 30 | 2 + 12 way, Double door |
| 31 | Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. [Make- Legrand/Lauritz Knudsen (L&T)/ABB/Schneider/Siemens or as approved by EIC ] |
| 32 | Single pole 5-32A [Make- Legrand/Lauritz Knudsen (L&T)/ABB/Schneider/Siemens or as approved by EIC ] |
| 33 | Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required. |
| 34 | Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. [Make- Legrand/Lauritz Knudsen (L&T)/ABB/Schneider/Siemens or as approved by EIC ] |
| 35 | 40 amps |
| 36 | Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required [Wire make:- Finolex/Havells/RR Kable / Polycab/Gloster/KEI or as approved by EIC ] |
| 37 | 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire |
| 38 | 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire |
| 39 | 2 X 4 sq. mm + 1 X 4 sq. mm earth wire |
| 40 | 2 X 6 sq. mm + 1 X 6 sq. mm earth wire |
| 41 | Finishing of the PVC insulated wire ends by socketting with pin/ ring type copper sockets and insulated tapes etc., including supplying sockets, tapes. |
| 42 | i) 1.5 sqmm |
| 43 | ii) 2.5sqmm |
| 44 | iii) 4 sqmm |
| 45 | iv) 6 sqmm |
| 46 | Supplying and fixing metal box of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc as required. |
| 47 | 180 mm X 100 mm X 60 mm deep |
| 48 | 200 mm X 125 mm X 60 mm deep |
| 49 | Supplying and delivery of following size Armoured cables XLPE/PVC insulated are designed for 1.1 kV Stranded Aluminium conductor, high tensile galvanized steel wire/strip armour for mechanical protection, and PVC/FR PVC outer sheathing power cable of following size. (IS 7098 Part - 1/2011 with Up To Date Amendments.) [ Make: Gloster/Polycab/Havells/RR Kable/KEI/Finolex or as approved by EIC ] |
| 50 | 4 core 10 sqmm. |
| 51 | 4 core 16 sqmm. |
| 52 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. |
| 53 | Upto 35 sq. mm |
| 54 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. |
| 55 | 4 X 10 sq. mm (25mm) |
| 56 | 4 X 16 sq. mm (28mm) |
| 57 | Supplying and making outdoor end termination with cast resin compound including aluminium lugs and other jointing materials for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. |
| 58 | 4 X 16 sq. mm |
| 59 | Supplying & fixing medium gauge GI Pipe ( ISI-Medium) Protection with necessary fittings and jointing metarials as required as per GS. |
| 60 | 32 mm dia |
| 61 | LED Batten light (System lumen efficacy ≥105 <120 lm/Watt)Supplying, installation, Testing & Commissioning of LED surface mounted Batten light of following body material and construction as per IS: 10322 with driver (Replaceable) as per the requirement with Driver efficiency >85% ,Operating voltage AC 140-270 Volt, freq 50/60 hz, Operating temp range -5 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection, THD < 10% , P. F.≥0.95, IP20, CRI ≥80, Flicker free, (flicker should be below 5 %), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with, 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM (Standard Deviation Colour Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard and trade mark certificate (T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect i/c external connections with 1.5 sq. mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output. LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). (Make: Signify/Crompton/Wipro/Havells or as approved by EIC) |
| 62 | Double LED Fittings along with Supply and fixing of 02 Nos 18-20 Watt LED Tube as per specification. |
| 63 | Single LED Fittings along with Supply and fixing of 01 Nos 18-20 Watt LED Tube as per specification. |
| 64 | Supply & Delivery of 230V, 10W, B22, W/W LED Lamp. (Make: Signify/Crompton/Wipro/Havells or as approved by EIC) |
| 65 | Supplying and fixing brass batten/ angle holder including connection etc. as required. |
| 66 | Supply & Delivery of 10W Bulk Head LED Light Fitting Pressure Die Cast housing LED Bulkhead with IP 66 Protection and IK 09 input resistance suitable for surface and wall mounting applications having luminoius efficacy of 100lm/W [Make:- Signify (Philips) Cat No. WT202W LED10S CW PSU S3 PC/ Wipro/ Havells] |
| 67 | Supplying, installation, Testing & Commissioning of Flood light LED fixture powder coated pressure die cast aluminum body finish with corrosion resistance fasteners (SS hardware) & silicon gasket for proper sealing with driver as per the requirement with Driver efficiency >80%, Input voltage: 140-270 Volt AC, freq 50/60 hz, Operating temp range 0o to 50o C and working RH 10% - 90%, internal surge protection of 5 KV internal and external SPD min. 10 KV, L,N,E as per IEC 61000-4-5. The driver rated output wattage should be 10% to 15% higher than lamp rating and at least 2 driver for 200W & above and Driver efficiency >85%, THD < 10% as per IEC 61000-3-2 , P. F.≥0.9, IP- 66, IK-08 specified below, CRI >70, under voltage and over voltage protection, high efficiency lens with type II/III distribution as required with UV stabilized optical lens, life time(LED,Driver & electrical circuitry) of minimum 50000 Burning Hours (Life projection shall be calculated as per TM-21 methodology) and 70% of initial Lumen maintained till life ends. CCT 3000°K / 4000°K/ 5700°K /6000°K/6500°K, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect and LED Chips of SMD mid to high-power (2.5 to 4 watt for 200 watt and above, as per required (LM- 80 tested) and necessary inter-connections with 1.5 sq mm FR, PVC insulated copper conductor single core cable and earthing etc. asrequired with Minimum 5 year OEM comprehensive on-site warranty against manufacturing defects including driver and LED module. All test report except L80 should be from 3rd party NABL accredited Lab as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. System lumen efficacy shall be as below: System lumen efficacy ≥135 <135 lm/Watt (Page-6, Item No-7.1) |
| 68 | 100 watt (Make: Signify/Crompton/Wipro/Havells or as approved by EIC) |
| 69 | LED Smart Street light fixture, powder coated pressure die cast aluminium (System. System lumen efficacy >135 lm/Watt)Supplying, installation, Testing & Commissioning of Smart Street light LED fixture, powder coated pressure die cast aluminium body with built in or separate driver as per the requirement (< 700ma), Input voltage: 140-270 Volt AC, freq 50/60 hz, Operating temp range -15 deg to 50 deg centigrade, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2, P. F.≥0.95, IP-66, IK-08, CRI ≥70, under voltage and over voltage - EMC as per CISPR- 15, lenses for beam angle as per IESNA type I/II/III as per the width of the road and the project requirement., suitable to fit in up to 65mm dia pipe, life time of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K/ 4000°K/ 5700°K/6500°K (As per ANSI Bin), Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq. mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy >135 lm/Watt output. LM79 & LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). Smart inbuilt controller shall have following features. |
| 70 | 45 watt (Make: Signify/Crompton/Wipro/Havells or as approved by EIC) |
| 71 | Supplying & Fixing GI waterproof type looping cable box size 200x150x100 mm deep having 4 mm thick comprising of one 250 V 15 A kit-kat fuse unit, one NL on porcelain insulator, one compression type brass cable gland for upto 2- core 16 sqmm PVC/A cable and having lined with rubber gasketted GI top cover with brass machine screws etc., earthing terminal with lug, on steel tubular pole near base, including S&F 40x6 mm thick, MS clamps with bolts, nuts etc. including painting with anticorrosive paint. |
| 72 | S&F 50 mm. dia 1.5 mtr. long detachable type G.I. Double arm bracket, suitable for pole head. The arm bracket shall be properly welded with 15 mm. thick stifner plate of pole sleeve for strengthening incl. properly fixing arrangement with the pole by bolts, nuts and washer as per direction of EIC |
| 73 | Installation, testing and commissioning of pre-wired, fluorescent fitting / compact fluorescent fitting of all types, complete with all accessories and tube etc. directly on ceiling/ wall, including connection with 1.5 sq. mm FRLS/HFFR PVC insulated, copper conductor, single core cable and earthing etc. as required. |
| 74 | Fixing only outdoor / street light type fluorescent light fitting complete with all accessories to be fixed/projected from the wall of the building incl. making holes to building, S&F 40 mm dia GI pipe (ISI-Medium) 1.50 mts. average length, with GI socket at one end and thread at the other end & suitable bend to house the fitting & making necy. connections with S&F necy. length of 1.5 sqmm PVC insulated single core stranded annealed copper wire and making connections as required and mending good damages to wall and painting. |
| 75 | Fixing only lamp. |
| 76 | Supplying and fixing brass batten/ angle holder including connection etc. as required. |
| 77 | Fixing only bulk head/ Wall Bracket light fitting on wall /ceiling by screws etc. |
| 78 | Supply & delivery of AC 240V 50 Hz 48\\" sweep (1200 mm) ceiling fan complete with down rod, Canopy, fork incl S & F of P - 2 type capacitor as per IS specification & proper Manufacturer certificate of the capacitor and Safety Wire (supplied at the time of delivered the fans ) etc. without regulator, (Make- Usha 1200MM STRIKER PWD ISI 1 STAR (Safety Wire & S3 Capacitor) Br /Orient Electric- New Breeze (5yrs warranty),1200 mm sweep; 44W; 320 rpm; 225 cmm; 3 star ac ceiling fan or equivalent model of Crompton Greaves and as per direction of EIC as per direction of EIC. |
| 79 | Supplying & fixing Safety arrangement for AC Ceiling Fan by GI Strain Wire of suitable guage with one end fixed at RC clamp with special tye socket/nut bolts thimble which thoroughly crimped with the strian wire passing through down rod and also other end connected with armature spindle by its existing jum nut hole with special arrangement(sample aprove by EIC).the length of strain wire varies as per site situation also considering any type of work required i.e. enlarging the existing holes as per directio of EIC.(Test report of GI wire to be submitted) safety feasibility to be checked by EIC with its application., 2 U Clamp And 1 L Clamp incl all required accessories for fixing safety wire with ceiling fan motor body as per direction by EIC.(aprove make) |
| 80 | Supplying & Fixing MS fan clamp of two piece type for RC ceiling asper approved specification, fabricated from 40 mm x 9 mm MS flatincluding making good damages to building roof with satisfactoryfinishing and painting – (As per Drawing no. 475 of PWD Specification Book – May 1991). |
| 81 | Supply & Delivery of 230 V, 50 Hz, single phase, 85 watts, 18\\" (450mm), speed 1325 rpm (minimum), Bracket Fan and class of insulation: B, 4 nos. metal (Aluminium alloy) blades, copper winding, steel/Al body with metal back cover. Power Factor not less than 0.9 and minimum air delivery 110 cu.m/min (minimum), including capacitor with safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for compliant to IS 374:2019 and external connections with 1.5 sq.mm FR, PVC insulated copper conductor single core cable and earthing etc. as required. (Make: Crompton Cat No. STORM 2 PLUS Metal Balde with metal Canopy or Equivalent model of Orient Electric/USHA) |
| 82 | Supply & delivery of 230 V, 50 Hz, single phase, 40 watts , 9\\" (230 mm) Sweep, speed 1350 rpm (minimum), A.C. Exhaust Fan and class of insulation: B, 3 nos. metal (Aluminium alloy) blades, copper winding, steel/Al body. Power Factor not less than 0.9 and minimum air delivery 650 cmh (minimum) including capacitor with safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for compliant to IS 374:2019 and external connections with 1.5 sq.mm FR, PVC insulated copper conductor single core cable and earthing etc. as required. [Make:- EPC /Orient Electric Heavy Duty/ USHA Heavy Duty) |
| 83 | Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS/HFFR PVC insulated, copper conductor, single core cable, including providing and fixing phenolic laminated sheet cover on the fan box etc. as required. |
| 84 | Erection of wall bracket /ceiling fittings of all sizes and shapes containing upto two GLS lamps per fitting, complete with all accessories including connection etc. as required. |
| 85 | Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required. |
| 86 | a) Upto 450 mm sweep |
| 87 | Extra for fixing the louvers/ shutters complete with frame for a exhaust fan of all sizes. |
| 88 | Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. |
| 89 | Fixing of Metal Body AC wall bracket fan on wall by S&F rag bolts, nuts & washers (6 mm dia x 62 mm long) on 150mmX300mm best quality vernished wood or as reqd. incl. S&F 24/0.20 PVC insulated flexible copper wire 0.5 mt. length |
| 90 | 16 inch |
| 91 | Supply and Delivery of 7 Mtr. HDG Octagonal Poles in 3mm shaft thickness in MS Condition before Galvanization with Top A/F 70 mm, Bottom A/F 135 mm, Base Plate 225x225x16 mm suitable for wind speed 180 Km/hr. as per IS:875 and 4 Nos. M20x600 “J” Type Foundation Bolts as per EN-8 (Min UTS-600) & Anti-theft locking door arrangement for safety of MCBs, Terminal etc.A) Material grade of shaft shall be of S355JO/JR as per BSEN 10025 or Equivalent IS: 2062 grade E350 (BR)B) Materials grade of Base Plate shall be E250(BR) as per IS:2062C) Galvanization as per BSEN ISO:1461D) Fusion Welding as per ISO 3824-2:2021 (Make –Transrail/ Bajaj/Surya) |
| 92 | Construction of suitable Shallow foundation upto 10mtr. Octagonal Pole with M-20 grade concrete for Pole considering soil bearing capacity (SBC) 10T/sq. mtr. at 2 Mtr. depth with all materials and labour payment made as per PWD civil schedule & as per direction of EIC. Erection of Pole by using of lifting equipment like hydra etc. and fixing of foundation bolts , anchor plate etc. with necessary arrangement ,Testing commissioning of all electrical equipment of Pole like led fixtures, MCBs Terminal etc. with necessary connection and Bracket fixing hardware of Octagonal Pole |
| 93 | Supply & Fixing of Ring Type HDG Bracket made of (48.3 ODx2.9 thik.) Mild Steel Pipe as per IS:1161 suitable for install 4-6 Nos LED Flood Light. |
| 94 | Supplying, installation, testing and commissioning of Astronomical time switch of following configuration to be mounted in feeder pillars / Lighting DBs for automatic switching On & OFF of street lights at sun set & sun rise or twilight (Auto ON, Auto OFF, Auto modes) with manual override facility with 12/24 hour display format with suitable battery and indication for relay status i/c programming at site complete as required. (Brand as approved by EIC) |
| 95 | output per phase and suitable for single phase supply. |
| 96 | S & F 240V single MF-I starter for Outdoor light. (Make : LK Cat No. MN 16 DOL SS94351/ABB/Havells) |
| 97 | Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required. |
| 98 | Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required. |
| 99 | Excavation of soil for installation of Earth Electrode and filling & ramming. (For Morum Soil) |
| 100 | Dismeltening of all existing electrical Items & deposit to the hospital authority Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Oct 15, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedOct 31, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 13 daysNov 02, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 15 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender