Tender For Repair & Maintenance Of Civil And Electrical Installation Works In Residential Quarters At Darikuri Phc Under Joypur Block In The District Of Purulia.--- Electrical Installation Works.
Tender Value
Ref. Documents
Estimated cost
Bid Submission
31 Oct 2026
13 days left
EMD
63884
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Purulia → West Bengal
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Repair & Maintenance Of Civil And Electrical Installation Works In Residential Quarters At Darikuri Phc Under Joypur Block In The District Of Purulia.--- Electrical Installation Works.
BOQ
| Sl. No. | Item Description |
| 1 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit, with piano type switch, phenolic laminated sheet, suitable size M.S. box and earthing the point with 1.5 sq.mm. FRLS/HFFR PVC insulated copper conductor single core cable etc as required. Group A (Wire [ Make: Gloster/Polycab/Havells/RR Kable/KEI/Finolex] or make as approved by EIC and Switchs make as approved by EIC) |
| 2 | Supplying and fixing metal box of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc as required. |
| 3 | 100 mm X 100 mm X 60 mm deep |
| 4 | 150 mm X 75 mm X 60 mm deep |
| 5 | Supplying and fixing following piano type switch/ socket on the existing switch box/ cover including connections etc. as required. (Make as approved by EIC) |
| 6 | 5/6 amps switch |
| 7 | 3 pin 5/6 amp socket outlet |
| 8 | 15/16 amp switch |
| 9 | 6 pin 15/16 amp socket outlet |
| 10 | Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required . [Wire make:- Finolex/Havells/RR Kable / Polycab/Gloster/KEI or as approved by EIC ] |
| 11 | 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire |
| 12 | 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire |
| 13 | 2 X 4 sq. mm + 1 X 4 sq. mm earth wire |
| 14 | Supply of 4/3.5 Core XLPE Insulated & Sheathed Armoured Aluminium Conductor cables for Working Voltage up to 1100 Volts of following sizes [ Make: Gloster/Polycab/Havells/RR Kable/KEI/Finolex or as approved by EIC ] |
| 15 | 2 Core 10 sq mm |
| 16 | 4Core 70 Sq. mm |
| 17 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. |
| 18 | Upto 35 sq. mm |
| 19 | Above 35 sq. mm and upto 95 sq. mm |
| 20 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. |
| 21 | 2 X 10 sq. mm (19 mm) |
| 22 | 3½ X 70 sq. mm (38 mm) |
| 23 | Supply and installation of L.T. cubical type fully compartmentalized distribution panel board, having rigid and self supporting structure fabricated with 14 SWG CRCA sheet with M.S. angle iron frame (main frame with 50 x 50 x 6 mm angle and each vertical compartment with 40 x 40x6 mm MS angle iron). The base of panel should be made with 75mm x 40mm x 4.4 mm M.S. channel. [Manufacturer/Fabricator having Test Certificates from CPRI]. An Auto Cad Drawing of the panel has to approved by EIC before making of panel. (All incoming and Outgoing main Switch make Will be Legrand/Lauritz Knudsen (L&T)/ABB/Schneider/Siemens or as approved by EIC ] |
| 24 | Incomming: 1) 415V, 125 A ,TPN on load front operated Change over switch open execution. -- 01 Nos.2) 415V, 125 A, 25KA/35KA breaking capacity 4P MCCB - 01 Nos. |
| 25 | Busbar:415V, 200Amp capacity 99.9% – 99.5% electrolytic tinned 4 bar copper bus bar [4x20x5mm] of suitable length mounted on non-hygroscopic porcelain insulator / hylam sheet having sufficient di-electric strength duly wrapped with colour PVC tapes (Red, yellow, blue & black) for phases & neutral identification - 1 set. The busbar is to be rigidly supported on suitable non-hygroscopic insulating materials of robust ration to with stand electromechanical stress in the event of earth fault. All connection to bus to made by suitable nuts & bolts. The busbar is too wrapped with coloured PVC (Red. Yellow, Blue & Black) for colour identifications |
| 26 | Out going : 1) 415V, 100 A, 25KA/35KA breaking capacity, 4P MCCB - 02 Nos. 2) 415V 63A , 25KA/35 KA breaking capacity, 4P MCCB- 02 Nos. 3) 32 A , 25 kA breaking capacity ,4P MCCB- 02 Nos.4) 32A DP MCB (Ç'characteristics, breaking capacity 10 KA)- 04 nos |
| 27 | Instruments: i) Supply and fixing 0-500 V. Digital Multifunction meter Having parameter of V, A, F, PF, kW, kVA, kVAR, kWh, kVAh, kVARh, Runhours, On hours, Phase angle, Interrupts, THD, Events (High-Low), Neutral, Current , K Factor , Accuracy Class - 01 (Make: LK(L&T) Cat No. WL441011OOOO (MFM 4410 LED meter Cl 1 with RS485)/Siemens/ABB) ----- 01 Nos ii) 300/5A CT (Kappa Make)-3nos,iii)LED type indicating lamp (RYB)with sliding fuses(seimens/Esbee)-3set,iv) 6A TPMCB-1no,v) EI Danger board 1 no. |
| 28 | All interconnection between incoming main to Busbar are to be made with suitable size flexible pve insulated multistranded single core Cu cable and Cu Busbar.1) Connection between 63A/MCCB TPN SFU with Busbar and SFU outgoing with cable alley terminal block by Single Core multi strand Copper 16 Sq. mm UA Cable.2) Connection between 32A TPN SFU /MCCB with Busbar and SFU outgoing with cable alley terminal block by Single Core multi strand Copper 6 Sq. mm UA Cable.3) Connection between 100 A Main Incommer with Busbar and SFU outgoing with cable alley terminal block by 60-65 Sq.mm size each Copper Busbar. or Single Core multi strand Copper 25 Sq. mm UA Cable.4) Connection between 125 A Change Over with Main Busbar by 78-80 Sq.mm size each Copper Busbar or Single Core multi strand Copper 25 Sq. mm UA Cable. |
| 29 | Earthing :- A separate continuous aluminum earth busbar of size 50mm x 6mm shall run across the full length of the panel board . All electrical equipment are to be properly earthed with suitable size G.I. wire. |
| 30 | The complete panel board is to be spray painted after required surface treatment by 9 tanks process / sand blasting with 2 coat of red oxide primer & 2 coat of finished paint over dried or powder coating. |
| 31 | Installation :-The complete panel board is to be installed on suitable brick padestal as directed by the E.I.C. All incoming/outgoing switches is to be properly lebeled on Acrylic sheet as per direction of EIC. |
| 32 | Supplying and fixing 230V, 63A SPN Sheet steel Main Switches on angle iron frame on wall. [Make- Legrand/Lauritz Knudsen (L&T)/ABB/Schneider/Siemens or as approved by EIC ] |
| 33 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) [Make- Legrand/Lauritz Knudsen (L&T)/ABB/Schneider/Siemens or as approved by EIC ] 2 + 12 way, Double door |
| 34 | Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. [Make- Legrand/Lauritz Knudsen (L&T)/ABB/Schneider/Siemens or as approved by EIC ] 63 amps |
| 35 | Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. [Make- Legrand/Lauritz Knudsen (L&T)/ABB/Schneider/Siemens or as approved by EIC ] Single pole . |
| 36 | Supplying, installation, testing and commissioning of Astronomical time switch of following configuration to be mounted in feeder pillars / Lighting DBs for automatic switching On & OFF of street lights at sun set & sun rise or twilight (Auto ON, Auto OFF, Auto modes) with manual override facility with 12/24 hour display format with suitable battery and indication for relay status i/c programming at site complete as required. [Make- Legrand/Lauritz Knudsen (L&T)/ABB/Schneider/Siemens or as approved by EIC ] 3 output(1output per phase) and suitable for three phase supply. |
| 37 | Supply & delivery of 8.5 Mtr long swaged type steel tubular pole (Specification no 410 SP 20,weight 115 Kg,base plate-5 Kg) with base plate & pole cap incl pole incl painting the pole & Arm bracket as to GS. ISI Medium |
| 38 | Erection of steel tubular or rail pole strut in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size ) foundation including excavation and refilling and secured with holding clamps, bolts, nuts, etc. as required. |
| 39 | Painting of Steel Tubular Pole of lengths and no. of coats of paint, as given below with ready mixed paint/primer of approved make, and brand incl. preparation of surface by sand paper/emery paper, cleaning etc. for receiving fresh coat of paint.Upto 9.0 mtr. long pole |
| 40 | 1st coat of aluminium paint over 1 coat of RO priming |
| 41 | 2nd coat of aluminium paint over 1st coat |
| 42 | Supplying & Fixing GI waterproof type looping cable box size 200x150x100 mm deep having 4 mm thick comprising of one 250 V 15 A kit-kat fuse unit, one NL on porcelain insulator, one compression type brass cable gland for upto 2- core 16 sqmm PVC/A cable and having lined with rubber gasketted GI top cover with brass machine screws etc., earthing terminal with lug, on steel tubular pole near base, including S&F 40x6 mm thick, MS clamps with bolts, nuts etc. including painting with anticorrosive. |
| 43 | Fixing only outdoor / street light type fluorescent light fitting complete with all accessories to be fixed/projected from the wall of the building incl. making holes to building, S&F 40 mm dia GI pipe (ISI-Medium) 1.50 mts. average length, with GI socket at one end and thread at the other end & suitable bend to house the fitting & making necy. connections with S&F necy. length of 1.5 sqmm PVC insulated single core stranded annealed copper wire and making onnections as required and mending good damages to wall and painting |
| 44 | Fixing outdoor type fluorescent/SV/MV light fitting on pole including S&F 40 mm dia x 1.68 mts. long GI Pipe (ISI-Medium) double arm bracket with 40 mmx10 mm thick, MS clamp etc. and providing wiring with 2x1/1.40 PVC insulated & sheathed wire (single core) partly in GI conduit & partly through above bracket from OH line to the fitting, without control switch, incl. making connections and painting. |
| 45 | Fixing outdoor type fluorescent/SV/MV light fitting on pole including S&F 40 mm dia x 1.68 mts. long GI Pipe (ISI-Medium) tripple arm bracket with 40 mmx10 mm thick, MS clamp etc. and providing wiring with 2x1/1.40 PVC insulated & sheathed wire (single core) partly in GI conduit & partly through above bracket from OH line to the fitting, without control switch, incl. making connections and painting . |
| 46 | Installation, testing and commissioning of pre-wired, fluorescent fitting / compact fluorescent fitting of all types, complete with all accessories and tube etc., including supplying and fixing ball and socket arrangement, 2 no. down rods of 20 mm dia X 1.6 mm thick steel conduit upto 30 cm length, painting and wiring the down rods and connection with 1.5 sq. mm FRLS/HFFR PVC insulated, copper conductor, single core cable and earthing etc. as required. |
| 47 | Providing and fixing extra conduit down rod of 20 mm dia, 2 X 10 cm length wiring with 2 X 1.5 sq. mm FRLS/HFFR PVC insulated, copper conductor, single core cable including painting etc. as required. (Note : More than 5 cm length shall be rounded to the nearest 10 cm and 5 cm or less shall be ignored) |
| 48 | Supplying and fixing PVC batten/ angle holder including connections etc. as required. |
| 49 | Fixing only outdoor / street light type fluorescent light fitting or LED light fitting complete with all accessories to be fixed /projected from the wall of the building incl. making holes/providing clamping arrangement & necy. GI reducer as required. S&F 40 mm GI pipe (ISI-Medium) quality 1.5 mts. average length having suitable bend S&F necy. length of 1.5 sqmm PVC insulated single core stranded annealed copper wire and making connections as required and mending good damages to wall incl. painting etc. |
| 50 | LED Batten light (System lumen efficacy ≥120 <135 lm/Watt)Supplying, installation, Testing & Commissioning of LED surface mounted Batten light of following body material and construction as per IS: 10322 with driver (Replaceable) as per the requirement with Driver efficiency >85% ,Operating voltage AC 140-270 Volt, freq 50/60 hz, Operating temp range -5 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection, THD < 10% , P. F.≥0.95, IP20, CRI ≥80, Flicker free, (flicker should be below 5 %), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with, 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM (Standard Deviation Colour Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard and trade mark certificate (T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect i/c external connections with 1.5 sq. mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 <135 lm/Watt output. LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). |
| 51 | Powder coated die cast /Extruded aluminium Body (Thickness ≥ 1.20 mm) 18-22 watt (Make: As Approved by EIC) |
| 52 | Supply & Delivery of Single LED Tube light fittings (Make- Philips Cat No- Mas LED Tube 1200mm 18W 865 T8 I – 2100 lm /Crompton- Cat No- CIS-341- 20-65--SL-NWH or equivalent model of Havells) |
| 53 | Supply and fixing of 230V 9W LED Bulb (Make- Phillips/Crompton/ Havells) |
| 54 | Supplying & Fixing bulk head light fitting (Havells make) with die cast aluminium housing & frosted glass on wall/ceiling incl. Supply and fixing LED Bulk Head. (Make: Philips WT202W LED6S NW PSU S3 PC/Crompton/Havells) |
| 55 | LED Street light fixture, powder coated pressure die cast aluminium body (System lumen efficacy ≥105 <120 lm/Watt)Supplying, installation, Testing & Commissioning of Street light LED fixture powder coated pressure die cast aluminium body with driver as per the requirement with Driver efficiency >85%, Input voltage: 140-270 Volt AC, freq 50/60 hz, Operating temp range -5 deg to 50 deg centigrade, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%, THD < 10% as per IEC 61000-3-2, P. F.≥0.95, IP-66, IK-10, CRI ≥70, under voltage and over voltage protection, EMI-EMC As per CISPR -15, lenses for beam angle as per IESNA type I/II/III as per the width of the road and the project requirement., suitable to fit in up to 65mm dia pipe, life time (LED, Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM- 21-11 report, CCT 3000°K/ 4000°K/ 5700°K/ 6500°K (As per ANS Bin), SDCM (Standard Deviation Colour Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq. mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output. LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). |
| 56 | 72 watt (Make: As Approved by EIC) |
| 57 | Supply & Fixing Socket type fan regulator (Step type) (Brand approved by EIC) on existing sheet metal switch board with bakelite/perspex top cover by screw after making housing for regulator knob by cutting bakelite/perspex top cover incl. making necy. connections etc. (Make: As Approved by EIC) |
| 58 | Supplying & Fixing MS fan clam of two piece type for RC ceiling as per approved specification, fabricated from 40 mm x 9 mm MS flat including making good damages to building roof with satisfactory finishing and painting – (As per Drawing no. 475 of PWD Specification Book – May 1991) |
| 59 | Supplying & fixing medium gauge GI Pipe ( ISI-Medium) Protection with necessary fittings and jointing metarials as required |
| 60 | 32 mm dia |
| 61 | 80 mm dia |
| 62 | Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS/HFFR PVC insulated, copper conductor, single core cable, including providing and fixing phenolic laminated sheet cover on the fan box etc. as required. |
| 63 | Supplying and fixing extra conduit down rod of 20 cm length G.I. pipe 15 mm dia, heavy gauge including painting etc. as required. (Note : More than 5 cm length shall be rounded to the nearest 10 cm and 5 cm or less shall be ignored) |
| 64 | Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required. |
| 65 | Upto 450 mm sweep |
| 66 | Extra for fixing the louvers/ shutters complete with frame for a exhaust fan of all sizes. |
| 67 | Supply & delivery of AC 240V 50 Hz 48\\" sweep (1200 mm) ceiling fan complete with down rod, Canopy, fork incl S & F of P - 2 type capacitor as per IS specification & proper Manufacturer certificate of the capacitor and Safety Wire (supplied at the time of delivered the fans ) etc. without regulator, (Make- Usha 1200MM STRIKER PWD ISI 1 STAR (Safety Wire & S3 Capacitor) Br /Orient Electric- New Breeze (5yrs warranty),1200 mm sweep; 44W; 320 rpm; 225 cmm; 3 star ac ceiling fan or equivalent model of Crompton Greaves and as per direction of EIC as per direction of EIC. 1200 mm Sweep. |
| 68 | Supply of Exhaust fans complete with all accessories having the following Model / Cat No. ( Make -EPC ) 9\\" ( 230mm ) Speed 1370 RPM [NS] |
| 69 | Excavation of soil for installation of Earth Electrode and filling & ramming as per GS For Morum Soil |
| 70 | Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required. |
| 71 | Providing and fixing earth bus of 50 mm X 5 mm copper strip on surface for connections etc. as required. |
| 72 | Supplying and laying 6 SWG G.I. wire at 0.50 metre below ground level for conductor earth electrode, including connection/ termination with GI thimble etc. as required. |
| 73 | Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm) |
| 74 | Dismantling the old electrical wirings, fittings, fixtures, plug points, panels, DBs, loop boxes, busbar chambers etc and shifting the same at the store room specifeid by the authority without affecting the heatlty parts. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Oct 15, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedOct 31, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 13 daysNov 02, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 15 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender