Housing Urban and Rular Development Government Departments Closing in 13 days TDR #58051074

Tender For Repair & Maintanance Of Existing Quarters, Renovation Of Electrical Installation Work For Govt. Quarters Of Barjora B.P.H.C In The District Of Bankura--- Electrical Installation Works.

Issued by Government Departments · Bankura, West Bengal
Tender Value
Ref. Documents
Estimated cost
Bid Submission
31 Oct 2026
13 days left
EMD
52093
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Bankura → West Bengal
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Repair & Maintanance Of Existing Quarters, Renovation Of Electrical Installation Work For Govt. Quarters Of Barjora B.P.H.C In The District Of Bankura--- Electrical Installation Works.

BOQ

Name of Work:- Repair & Maintanance of existing quarters, renovation of Electrical Installation work for Govt. Quarters of Barjora B.P.H.C in the district of Bankura--- Electrical Installation Works.
Sl. No. Item Description
1Supplying and fixing 240V 60/63 A DP main switch with fuse on L&N Sheet steel Main Switches on flat iron frame on wall (for type A quarter) ( Make: HPL/ Anchor/ Havells/Standard)
2Supplying and fixing 240V 30/32 A DP main switch with fuse on L&N Sheet steel Main Switches on flat iron frame on wall. (for type C & D quarter) ( Make: HPL/Anchor/ Havells/Standard)
3Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) [Make- Legrand/Lauritz Knudsen (L&T)/ABB/Schneider/Siemens or as approved by EIC ]
416 Way, Double door
512 Way, Double door
6Supplying and fixing following rating, double pole, 240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. [Make- Legrand/Lauritz Knudsen (L&T)/ABB/Schneider/Siemens or as approved by EIC ]
7Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. [Make- Legrand/Lauritz Knudsen (L&T)/ABB/Schneider/Siemens or as approved by EIC ]
8Single pole
9Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable etc. as required. (Wire Make: Gloster/Polycab/Havells/RR Kable/KEI/Finolex] or make as approved by EIC and Switchs Brand and Model as approved by EIC)
10Group C
11Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. (Make: Precision or Brand as approved by EIC)
1220 mm
1325 mm
1432 mm
15Supplying and drawing following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. (Wire Make: Gloster/Polycab/Havells/RR Kable/KEI/Finolex] or make as approved by EIC
163 x 1.5 sq. mm
173 x 2.5 sq. mm
183 x 4 sq. mm
193 x 6 sq. mm
205 x 6 sq. mm
21Finishing of the PVC insulated wire ends by socketting with pin/ ring type copper sockets and insulated tapes etc., including supplying sockets, tapes.
221.5 sqmm
232.5sqmm
244 sqmm
256 sqmm
2610 sqmm
27Supplying & Fixing GI Modular Switch Board of the following sizes complete with three no. suitable size Copper bar with holes (for Ph, N & E) fixed on bakelite/Hard Rubber insulator over the MS welded chairs incl. top cover flushed in wall for housing the board after cutting the brick wall incl. making earthing attachment, painting and mending good damages to building works . (Brand and Model as approved by EIC)
282 Row 18 Module
29Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc. as required.
304 Module (125mmX75mm)
316 Module (200mmX75mm)
32Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. asrequired. (Brand and Model as approved by EIC)
335/6 A switch
3415/16 A switch
353 pin 5/6 A socket outlet
366 pin 15/16 A socket outlet
37Supply & Fixing 240 V, 25 A, Modular type starter with 25A Modular switch type DP MCB (CCurve) and 4 Module GI Modular type switch board with 4 Module top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc. (Brand and Model as approved by EIC)
38Supply & Fixing 240 V, 25 A, 3 pin Modular type plug socket (without plug top and switch with 2 Module GI Modular type switch board with top cover plate flushed in wall and making necy. connections with PVC Cu wire and earth continuity wire etc. ( Brand and Model as approved by EIC)
39Supply & Fixing 240 V,25 A, 3 pin Modular type plug top with indicator & necy. Connections. (Brand and Model as approved by EIC)
40Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.
41Supplying and fixing call bell/ buzzer suitable for single phase, 230 V, complete as required.
42Supplying and delivery of following size Armoured cables XLPE/PVC insulated are designed for 1.1 kV Stranded Aluminium conductor, high tensile galvanized steel wire/strip armour for mechanical protection, and PVC/FR PVC outer sheathing power cable of following size. (IS 7098 Part - 1/2011 with Up To Date Amendments.) (Make: Gloster/Polycab/Havells/RR Kable/KEI/Finolex or make as approved by EIC
432 core 6 sqmm.
44Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required.
45Upto 35 sq. mm
46Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.
472 X 6 sq. mm (19mm)
48LED Batten light (System lumen efficacy ≥120 <135 lm/Watt)Supplying, installation, Testing & Commissioning of LED surface mounted Batten light of following body material and construction as per IS: 10322 with driver (Replaceable) as per the requirement with Driver efficiency >85% ,Operating voltage AC 140-270 Volt, freq 50/60 hz, Operating temp range -5 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection, THD < 10% , P. F.≥0.95, IP20, CRI ≥80, Flicker free, (flicker should be below 5 %), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with, 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM (Standard Deviation Colour Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard and trade mark certificate (T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect i/c external connections with 1.5 sq. mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM
49Single LED Fittings along with Supply and fixing of 01 Nos 18-20 Watt LED Tube as per specification. (Make: Signify/Crompton/Wipro/Havells or Brand and model as approved by EIC)
50Supply of 10W Bulk Head LED Light Fitting Pressure Die Cast housing LED Bulkhead with IP 66 Protection and IK 09 input resistance suitable for surface and wall mounting applications having luminoius efficacy of 100lm/W [Make:- Signify (Philips) Cat No. WT202W LED10S CW PSU S3 PC/ Wipro/ Havells]
51LED Street light fixture, powder coated pressure die cast aluminium body (System lumen efficacy ≥105 <120 lm/Watt) Supplying, installation, Testing & Commissioning of Street light LED fixture powder coated pressure die cast aluminium body with driver as per the requirement with Driver efficien cy >85%, Input voltage: 140-270 Volt AC, frequency 50/60 hz, Operating temp range -5 0C to 50 0C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2, P. F.≥0.95, IP-66,IK-10, CRI >70, under voltage and over voltage protection, EMIEMC As per CISPR -15, lenses for beam angle as per IESNA type I/II/III as per the width of the road and the project requirement., suitable to fit in up to 65mm dia pipe, life time (LED, Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin),SDCM (Standard Deviation ColourMatching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard completein all respect i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output .LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). 50W (Make: Signify/Crompton/Wipro/Havells or Brand and model as approved by EIC)
52Fixing only outdoor / street light type fluorescent light fitting or MV light fitting complete with all accessories to be fixed /projected from the wall of the building incl. making holes/providing clamping arrangement & necy. GI reducer as required. S&F 40 mm GI pipe (ISI-Medium) quality 1.5 mts. average length having suitable bend S&F necy. length of 1.5 sqmm PVC insulated single core stranded annealed copper wire and making connections as required and mending good damages to wall incl. painting etc.
53Supply & Fixing of 240 volt. 12W LED Bulb. (Make: Havells Comfy Vizon LED 12 W B22 CDL 3 Star V2, Cat No.LHLDDDENI5R12 or equivalent make of Crompton/Philips/Wipro )
54Supplying and fixing PVC batten/ angle holder including connections etc. as required
55Supply & delivery of AC 240V 50 Hz 48\\" sweep (1200 mm) ceiling fan complete with down rod, Canopy, fork incl S & F of P - 2 type capacitor as per IS specification & proper Manufacturer certificate of the capacitor and Safety Wire (supplied at the time of delivered the fans ) etc. without regulator, (Make- Usha 1200MM STRIKER PWD ISI 1 STAR (Safety Wire & S3 Capacitor) Br /Orient Electric- New Breeze (5yrs warranty),1200 mm sweep; 44W; 320 rpm; 225 cmm; 3 star ac ceiling fan or equivalent model of Crompton Greaves and as per direction of EIC as per direction of EIC.
56Installation, Testing and Commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS/HFFR PVC insulated, copper conductor, single core cable, including providing and fixing phenolic laminated sheet cover on the fan box etc. as required.
57Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excludingmodular plate etc. as required.
58Supply & Delivery of 230 V, 50 Hz, single phase, 85 watts, 18\\" (450mm), speed 1325 rpm (minimum), Bracket Fan and class of insulation: B, 4 nos. metal (Aluminium alloy) blades, copper winding, steel/Al body with metal back cover. Power Factor not less than 0.9 and minimum air delivery 110 cu.m/min (minimum), including capacitor with safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for compliant to IS 374:2019 and external connections with 1.5 sq.mm FR, PVC insulated copper conductor single core cable and earthing etc. as required. (Make: Crompton Cat No. STORM 2 PLUS Metal Balde with metal Canopy or Equivalent model of Orient Electric/USHA)
59Erection of wall bracket /ceiling fittings of all sizes and shapes containing upto two GLS lamps per fitting, complete with all accessories including connection etc. as required.
60Supply & Delivery of 240 volt. 9\\"/230mm Exhaust Fan . (Make: EPC Heavy Duty/ USHA 230MM AEROCLEAN PLUS DBB GBD /Crompton Heavy Duty )
61Installation, Testing and Commissioning of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. asrequired.
62Upto 450 mm sweep.
63Supply & Fixing GI sheet (20SWG) metal Cowl with MS flat iron frame & GI wire mesh on wall as per GS
64(9\\"/12\\")
65Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required.
66Cutting of Wall upto 12\\" Thick and 12\\" Bore for housing of Exhaust Fan including Finishing and painting after cutting as per direction of EIC.
67Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required.
68Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm)
69Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required.
70Supplying and laying 6 SWG G.I. wire at 0.50 Meter below ground level for conductor earth electrode, including connection/ termination with GI thimble etc. as required.
71Dismantling charges of existing distribution wiring, distribution boards,power boards,fittings etc as per direction of EIC. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 58051074
AUTHORITY Government Departments
TENDER VALUE Ref. Documents
LAST DATE 31-10-2026
Authority
Authority Name Public Works Department
Work Description Tender for Repair & Maintanance Of Existing Quarters, Renovation Of Electrical Installation Work For Govt. Quarters Of Barjora B.P.H.C In The District Of Bankura--- Electrical Installation Works.
Basic Detail
Tender No WBPWD/SE/SWEC/NIQ46/2026-27
Bidding Type Tender
Location
City Bankura
State West Bengal
Key Dates
Publish Date 15 Oct 2026
Submission Date 31 Oct 2026
Open Date 02 Nov 2026
Finance
Tender Value Ref. Documents
Tender Fee Ref. Documents
EMD 52093
Exemption Not Available
Document List
1bc435da-505d-4139-ab7e-635efceb61ee.html
BOQ_5187738.xls
Tendernotice_1.pdf
Tendernotice_2.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Oct 15, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Oct 31, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 13 days
Nov 02, 2026

Bid Opening Date

Technical bids will be opened and evaluated.