Housing Urban and Rular Development Government Departments Closing in 2 days TDR #58050930

Tender For Repair And Renovation Of 1 Nos. Bmoh Quarter, 3 Nos. maintenance of Quarter, 6 Nos. Group C Quarter And 2 Nos. Group D Quarter At Sandelarbil Rh In The District Of North 24 Parganas. (Electrical Installation Work)

Issued by Government Departments · 24 Paraganas North, West Bengal
Tender Value
17.46 Lakhs
Estimated cost
Bid Submission
30 Oct 2026
2 days left
EMD
34929
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
24 Paraganas North → West Bengal
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Repair And Renovation Of 1 Nos. Bmoh Quarter, 3 Nos. maintenance of Quarter, 6 Nos. Group C Quarter And 2 Nos. Group D Quarter At Sandelarbil Rh In The District Of North 24 Parganas. (Electrical Installation Work)

BOQ

Name of Work:- Repair and renovation of 1 nos. BMOH quarter, 3 nos. MO quarter, 6 nos. Group C quarter and 2 nos. Group D quarter at Sandelarbil RH in the district of North 24 Parganas. (Electrical Installation work)
Sl. No. Item Description
1Supplying and fixing DP sheet steel enclosure on surface/ recess along with 25/32 A 240 V \\"C\\" curve DP MCB complete with connections, testing and commissioning etc. as required. CPWD/P- 16 /Item- 2.16
2Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)8 way, Double door CPWD/P- 14 /Item- 2.3
36 way , Double door (For Inverter Connection at Qtr) CPWD/P- 14 /Item- 2.3
4Supplying and fixing following rating, double pole, 240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 A CPWD/P- 15 /Item- 2.12
5Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required .Single pole CPWD/P- 15 /Item- 2.10
6Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required.Upto 35 sq. mm (clamped with 1mm thick saddle) (For Security Light---2 Core 6 sq mm) CPWD/P- 66 /Item- 10.7
7Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 2 X 6 sq. mm (19mm) CPWD/P- 68 /Item- 11.1
8Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS/HFFR PVC insulatedcopper conductor single core cable in surface/ recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable etc. as required.Group B CPWD/P- 3 /Item- 1.10.2
9Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire (For Secirity Lightingh----From Loop Box to Fittings) CPWD/P- 3 /Item- 1.14
10Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 2 nos. 3 pin 5/6 A modular socket outlet and 2 nos. 5/6 A modular switch, connections etc. as required. (For light plugs to be used in non residential buildings). CPWD/P- 11 /Item- 1.56
11Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modularswitches in recess etc. as required. CPWD/P- 7 /Item- 1.271 or 2 Module (75mmX75mm) (For Security Light) CPWD/P- 7 /Item- 1.27
123 Module (100mmX75mm) (For Wasing M/C, Refrigerator, Geyser & Inverter) CPWD/P- 7 /Item- 1.27
136 Module (200mmX75mm) (For Kitchen Appliance) CPWD/P- 7 /Item- 1.27
14Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. CPWD/P- 7 /Item- 1.24 5/6 A switch (For Security Lighht) CPWD/P- 7 /Item- 1.24
1515/16 A switch CPWD/P- 7 /Item- 1.24
166 pin 15/16 A socket outlet CPWD/P- 7 /Item- 1.24
17Supplying and drawing following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required.3 x 1.5 sq. mm (For 2x6A Plug Popint) CPWD/P- 4 /Item- 1.17
183 x 2.5 sq. mm (For Power Plug) CPWD/P- 4 /Item- 1.17
193 x 4 sq. mm (For AC, Geyser) CPWD/P- 4 /Item- 1.17
203 x 6 sq. mm (For SPN DB) CPWD/P- 4 /Item- 1.17
21Supplying and fixing of following sizes of medium class PVC conduit along with accessories insurface/recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm CPWD/P- 6 /Item- 1.21
2225 mm CPWD/P- 6 /Item- 1.21
23LED Batten light (System lumen efficacy ≥105 <120 lm/Watt). Supplying, Installation, Testing & Commissioning of LED surface mounted Batten light of following body material and construction as per IS : 10322 with driver (Replaceable) as per the requirement with Driver efficiency >85%, Operating voltage AC 140- 270 Volt, frequency 50/60 hz, Operating temp range -5 °C to 40 °C, internal surge protection of 2.5 KV with Short & Open circuit protection, THD < 10%, P. F.≥0.95, IP20, CRI >80, Flicker free, (flicker should be below 5 %), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Colour Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in- Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). Powder coated die cast /Extruded aluminiumBody (Thickness > 1.20 mm) 18- 22 Watt CPWD/P- 45 /Item- 8.9
24Supplying and fixing PVC batten/ angle holder including connections etc. as required. CPWD/P- 11 /Item- 1.58
25Brush Less Direct Current (BLDC) Fan without Remote : Supply, Installation, Testing and Commissioning of ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. metal(Aluminium alloy) blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, steel/Al body. Power Factor not less than 0.9, Service Value (CM/M/W) minimum as below, 350 RPM (tolerance as per IS : 374-2019), THD (Total Harmonic Distortion) less than 10%, remote (preferably mobile app based) for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 0C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC supply Ceiling Fan compliant to IS 374:2019 fan i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required. 1200mm, service value ≥ 6.0 CM/Min/Watt, air delivery 210 CM/Min (Minimum) CPWD/P- 63 /Item- 9.2
26Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. CPWD/P- 7 /Item- 1.25
27Installation, Testing and Commissioning of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required.Upto 450 mm sweep CPWD/P- 10 /Item- 1.50
28Extra for fixing the louvers/ shutters complete with frame for a exhaust fan of all sizes. CPWD/P- 10 /Item- 1.51
29Supplying and fixing call bell/ buzzer suitable for single phase, 230 V, complete as required. CPWD/P- 9 /Item- 1.38
30Earthing with G.I. earth pipe 4.5 Meter long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required. CPWD/P- 30 /Item- 5.2
31Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm) CPWD/P- 31 /Item- 5.9
32LED Street light fixture, powder coated pressure die cast aluminium body (System lumen efficacy ≥105 <120 lm/Watt) Supplying, installation, Testing & Commissioning of Street light LED fixture powder coated pressure die cast aluminium body with driver as per the requirement with Driver efficiency >85%, Input voltage: 140-270 Volt AC, frequency 50/60 hz, Operating temp range -5 0C to 50 0C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2, P. F.≥0.95, IP-66,IK-10, CRI >70, under voltage and over voltage protection, EMIEMC As per CISPR -15, lenses for beam angle asper IESNA type I/II/III as per the width of the road and the project requirement., suitable to fit in up to 65mm dia pipe, life time (LED, Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin),SDCM (Standard Deviation Colour Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output .LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). 36 watt CPWD/P- 48 /Item- 8.12
33SUB-HEAD-1 -- METER BOARD, SFU, SPN DB ETCSupply & Fixing best quality water proof Hylam Sheet of 13mm Thick and Length-1' X Width - 1.5' to be fixed on wall by angle1 no frame including S&F one no. 250V, 32A Kit-Kat fuse one no Neutral link including connection.(To be fixed between Single phase energy meter supply by WBSEDCL and Main Switch Fuse Unit). NS
34Charges for dismentling the electrical installation such as wiring,cable,SPN,HTPN,change over switch,street light,Cilling light, post top,light fan fittings etc.by delopying Two (2) nos semi skill electrician and Two (2) nos Helper with his own tools & tackles and disposal the same to departmental store.
35Supplying and delivery of following size Armoured cables XLPE/PVC insulated are designed for 1.1 kV Stranded Aluminium conductor, high tensile galvanized steel wire/strip armour for mechanical protection, and PVC/FR PVC outer sheathing power cable of following size. (IS 7098 Part - 1/2011 with Up To Date Amendments.) [Polycab/Havells/Gloster] PWD/DS/DIFFERENT TYPE OF CABLE/Page : 1,Item : 1 2 core 6 sqmm [For Security Light] PWD/DS/DIFFERENT TYPE OF CABLE/Page : 1,Item : 1
36Supply & Fixing 240 V, 25 A, Modular type starter (Brand approved by EIC) with 25A Modular switch type DP MCB (CCurve) and 4 Module GI Modular type switch board with 4 Module top cover plate flushed in wall/surface on wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc [PWD/GS Page: E-19 Item: 17]
37Supply & Fixing 240 V, 25 A, 3 pin Modular type plug socket (Brand approved by EIC), without plug top and switch with 2 Module GI Modular type switch board with top cover plate flushed in wall/surface on wall and making necy. connections with PVC Cu wire and earth continuity wire etc.(For AC ) [PWD/GS Page: E-17 Item: 5/a]
38Supply & Fixing 240 V,25 A, 3 pin Modular type plug top with indicator (Brand approved by EIC) & necy. Connections. [For Inverter] [PWD/GS Page: E-17 Item: 5b]
39Finishing of the PVC insulated wire ends by socketting with pin/ring type copper sockets and insulated tapes etc., including supplying sockets, tapes. as per G S 3X1.5 sqmm [PWD/GS Page: F-5 Item: 9]
403x 2.5 sqmm [PWD/GS Page: F-5 Item: 9]
413x 4 sqmm [PWD/GS Page: F-5 Item: 9]
423x 6 sqmm [PWD/GS Page: F-5 Item: 9]
43Supply & Delivery of 240V LED lamps of following wattage with glare free light distribution having minimum luminous efficiency of 100 Lm/ Watt or better & 50,000 LED burning hours or more. [Make- Philips/ Crompton/ Wipro or manufacturer with own NABL accredited lab with valid test certificate] [LED lamps & accessories shall have BEE certification] 9W LED Bulb B22/E27 Base NS
44Supply & delivery of 230 V, 50 Hz, single phase, 80 watts, 12\\" (300 mm) Sweep, speed 1420 rpm (minimum), A.C. Exhaust Fan and class of insulation: B, 4 nos. metal (Aluminium alloy) blades, copper winding, steel/Al body. Power Factor not less than 0.9 and minimum air delivery 1710 cmh (minimum) capacitor with safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for compliant to IS 374:2019 and external connections with 1.5 sq.mm FR, PVC insulated copper conductor single core cable and earthing etc. as required. PWD/DS/All Types of FAN /Page : 2,Item : 3
45Supplying & Fixing MS fan clam of two piece type for RC ceiling as per approved specification, fabricated from 40 mm x 9 mm MS flat including making good damages to building roof with satisfactory finishing and painting – (As per Drawing no. 475 of PWD Specification Book – May 1991) [PWD/GS Page: D-14 Item: 29]
46Supplying & fixing earth busbar of galvanized (Hot Dip) MS flat 25 mm x 6 mm on wall having clearance of 6 mm from wall including providing drilled holes on the busbar complete with GI bolts, nuts, washers, spacing insulators etc. as required [PWD/GS Page: G-2 Item: 4/a]
47Fixing only outdoor / street light type fluorescent light fitting complete with all accessories to be fixed/projected from the wall of the building incl. making holes to building, S&F 40 mm dia GI pipe (ISI-Medium) 1.50 mts. average length, with GI socket at one end and thread at the other end & suitable bend to house the fitting & making necy. connections with S&F necy. length of 1.5 sqmm PVC insulated single core stranded annealed copper wire and making connections as required and mending good damages to wall and painting [PWD/GS Page: C-3 Item: 19 ]
48Supplying & Fixing GI waterproof type looping cable box size 200x150x100 mm deep having 4 mm thick comprising of one 250 V 15 A kit-kat fuse unit, one NL on porcelain insulator, one compression type brass cable gland for upto 2- core 16 sqmm PVC/A cable and having lined with rubber gasketted GI top cover with brass machine screws etc., earthing terminal with lug, on steel tubular pole near base, including S&F 40x6 mm thick, MS clamps with bolts, nuts etc. including painting with anticorrosive [PWD/GS Page: H-5 Item: 5 ] Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 58050930
AUTHORITY Government Departments
TENDER VALUE 17.46 Lakhs
LAST DATE 30-10-2026
Authority
Authority Name Public Works Department
Work Description Tender for Repair And Renovation Of 1 Nos. Bmoh Quarter, 3 Nos. maintenance of Quarter, 6 Nos. Group C Quarter And 2 Nos. Group D Quarter At Sandelarbil Rh In The District Of North 24 Parganas. (Electrical Installation Work)
Basic Detail
Tender No WBPWD/EE/N24/EL/e-NIT-85/26-27
Bidding Type Tender
Location
City 24 Paraganas North
State West Bengal
Key Dates
Publish Date 15 Oct 2026
Submission Date 30 Oct 2026
Open Date 02 Nov 2026
Finance
Tender Value 17.46 Lakhs
Tender Fee Ref. Documents
EMD 34929
Exemption Not Available
Document List
BOQ_5187940.xls
f6f94d1b-e0cd-4907-923d-d54e8715ef6b.html
Tendernotice_1.pdf
Tendernotice_2.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Oct 15, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Oct 30, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 2 days
Nov 02, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 5 days

Tender Documents

Download All (ZIP) ↓
xls

BOQ_5187940.xls

html

f6f94d1b-e0cd-4907-923d-d54e8715ef6b.html

pdf

Tendernotice_1.pdf

pdf

Tendernotice_2.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender