Tender For Diversion Of 11 Kv Oh Electrical Line (Feeder Of M/S Tpwodl) Due To Construction Of Overbridge At Sukhupatnayak Chowk, Lakhanpur Area
Tender Value
16.41 Lakhs
Estimated cost
Bid Submission
26 Oct 2026
6 days left
EMD
20600
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Jharsuguda → Odisha
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Diversion Of 11 Kv Oh Electrical Line (Feeder Of M/S Tpwodl) Due To Construction Of Overbridge At Sukhupatnayak Chowk, Lakhanpur Area
BOQ
| Sl. No. | Item Description |
| 1 | Supply of 09 mtr long RS Joist (GI) pole 150 x 150 mm (Weight - 34 6 Kg/mtr), Sectional Area (cm2) 44, Thickness of Flange (mm)- 9, Thickness of Web (mm) - 11.8, As per IS:1852, IS 2062/ S999 Grade-A |
| 2 | Supply of 11 mtr long RS Joist (GI) pole 150 x 150 mm (Weight - 34 6 Kg/mtr), Sectional Area (cm2) 44, Thickness of Flange (mm)- 9, Thickness of Web (mm) - 11.8, As per IS:1852, IS 2062/ S999 Grade-A |
| 3 | Erection of steel tubular or rail pole strut in cement concrete 1:3:6 (1 cement : 3 coarse sand: 6 graded stone aggregate 40 mm nominal size ) foundation including excavation and refilling and secured with holding clamps, bolts, nuts, etc. as required |
| 4 | Supply of conductor having nominal size- 100 sq. mm. Aluminium alloy stranded conductor and aluminium - magnesium - silicon type (AAAC) for over head transmission purpose conforming to IS 398 Part IV/1994 with amendment no. 1, (Reaffirmed 2004) PSI marked. Packing on drum conforming to IS 1778/80 |
| 5 | Erection of all aluminium conductor of 7/3.40 mm to 7/4.00 mm diameter and above including binding etc. as required. 1953 mtrx 0.27286 Kg per Mtr =532.90 Kg |
| 6 | Supplying and erection of a set of cross bracing FRLSame work for 11 KV over head line double pole structure having four members fabricated out of 50 mm X 50 mm X 6 mm angle iron to form a rectangle of minimum size 1400 mm width X 2500 mm height , complete with 50 mm X 6mm M.S. flat iron clamps, bolts and nuts including drilling holes for insulator pins, bolts and nuts etc (as per drawing) and painting with primer and finish paint as required |
| 7 | Supplying of two lengths of channel iron 75 mm X 40 mm X 6 mm (7.14 kg per metre) double pole cross arm for three wire 11KV over head line conductors complete with through bolts and nuts for clamping to the poles, 50 mm X 6 mm M.S. flats welded on one side to the channel iron and with bolts and nuts on the other side for tying the cross arms together, including drilling holes for insulator pins/ fittings, bolts, nuts and washers etc (as per drawing) and painting with primer and finish paint as required. |
| 8 | Erection of double pole 3 wire cross arm for 11KV/ 22KV/ 33 KV over head lines as required. |
| 9 | Supplying of 50 mm X 8 mm M.S. flat iron pole top bracket/ cross arm for single 11/22/33 KV over head line conductor complete with fixing clamps, bolts, nuts and washers drilling holes for insulator pins, bolts and nuts etc and painting with primer and finish paint as required. |
| 10 | Supplying of channel iron 75 mm X 40 mm X 6 mm (7.14 kg per metre) V shape cross arm for two 11 KV over head line conductors complete with 50 mm X 6mm M.S. flat iron clamps, bolts and nuts including drilling holes for insulator pins, bolts, nuts and washers etc (as per drawing) and painting with primer and finish paint as required. |
| 11 | Erection of pole top/ straight two wire/ V shape two wire, angle iron/ channel iron, cross arm on steel tubular/ rail/ PCC pole for 11/22/33 KV as required. |
| 12 | Supply & Erection of 11 KV grade, Minimum Failing Load-45KN, 320mm Creepage distance, Composite Silicone rubber disc insulator with |hardware fitting ( B&S type). As per IEC 61109, Grey Colour |
| 13 | Supply & Erection of 11 KV grade,5 KN, Silicone rubber, Fibre Glass rod( FRP), Boran free, Composite polymer pin insulator with nut s and head, Sectional Length -342 + 20 mm, Creepage distance-320 mm minimum. As per EC 61109 |
| 14 | Supplying and erection of stay set complete (galvanised) with 19/20 mm dia X 1.8 metres long stay rod, anchor plate of size 45 cm X 45 cm X 7.5 mm, thimble, stay clamps, turn buckle ( 20 mm X 60 cm), 7/ 4.00 mm dia G.I. stay wire and strain insulator etc in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size ) foundation including excavation and refilling etc. as required. |
| 15 | Guarding for road crossing |
| 16 | Dismantling of over head lines comprising of copper/ aluminium over head conductor, G I. wire, cross arms insulators etc. as required (i) Conductor - 10 span(100sqmm AAA) x 60 mtr. x 3 nos. wire = 1800 mtr = 1800 mtr x 0.27286 kg/m = 491.14 kg (ii) Disc Insulator - 12 nos. x 6.7 kg = 80.40 kg (iii) Pin Insulator - 30 nos. x 3.7 kg = 111 kg (iv) V shape Cross arm -08 nos. x 13.28 kg = 106.24 kg (v) DP Chanel 32.84 Kg per set x 2 set= 65.68 Kg (TOTAL -854.46Kg) |
| 17 | Dismantling of pole/ street light standard/ strut embedded in cement concrete foundation etc. as required |
| 18 | Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required. |
| 19 | Providing and fixing 25 mm X 5 mm GI. strip on surface or in recess for connections etc. as required. . |
| 20 | Total impact of GST plus Labour Cess [@ 1 % (BOCW Cess to be deducted from the RA bill as per the value of the work progress)] for the purpose of CTC Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Oct 14, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedOct 26, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 6 daysOct 27, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 7 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender