Tender For Rehabilitation Of Agl Network For Safety Improvement At Nscbi Airport, Kolkata
Tender Value
5.47 Crore
Estimated cost
Bid Submission
05 Nov 2026
13 days left
EMD
12.90 Lakhs
Bank guarantee accepted
Document Fee
3540
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
24 Paraganas North → West Bengal
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Rehabilitation Of Agl Network For Safety Improvement At Nscbi Airport, Kolkata
BOQ
| Sl. No. | Item Description |
| 1 | Kerf cutting with machine in taxiway/runway/apron/road of PQC/bituminous surface of depth upto 95 mm and width upto 20 mm, using expansion joints / construction joints as far as possible, cleaning, drying, disposing FODs including laying 1 or 2 nos secondary lead/LT cable by wrapping cotton tape, providing polysulphide / asphaltic compound, primar, backer rod ( both top and bottom) etc. complete as required along with arranging water bowser, mobile DG sets etc. whatever necessary to work in a operational airport. |
| 2 | Excavation of earth/soft soil mechanically/manually not exceeding 1.5 mtr in width, and lift upto 1.5mtr, including back filling, dressing, ramming and disposing of excess materials to a lead of 10 KM as required and as directed by the Engineer-In-Charge |
| 3 | Excavation of the trench in hard rock / bituminous / cement concrete of runways/taxiways/ apron/RESA/ Road etc. by power saw cutting without disturbing the other area, upto 1.5 mtr in width, and depth upto 1.0 mtr, including getting out the excavated soil, cleaning the cut area and disposal of excavated debris as directed within a lead of 10 KM including all machineries like power saw, hammer drill / pneumatic drill, water browser, mobile DG set, transportation etc. complete as required. |
| 4 | Providing and laying in position cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) including shuttering, sloping, surface finisfhing for Isolating transformer housing boxes / chambers etc. complete as required as per the site condition and as directed by Engineer-In-Charge. |
| 5 | Supplying and laying of following size UV stabilized, HDPE pipe (PE- 63, PN-6) as per IS - 4984 and IS marked with uptodate amendment along with accessories like socket, bend, couplers etc. complete with fitting, cuttings, jointing etc. below the ground (i/c Road crossing ,Cement concrete Apron Area, Runway, taxiway) at a depth upto 6 m by Horizontal Directional Drilling(HDD) or by Saw Cutting the DRLC / PQC upto required depth, fixing pipe with clamps, providing 100mmX100 mm X 75 mm GI / PVC box at pipe end for fitting wherever applicable and filling the saw cut cement concrete as per the direction of the Civil Department etc. complete as required after doing Ground Penetrating radar survey in case of HDD and submitting its report etc.complete as required.1 run X 63 mm dia (OD) |
| 6 | Supplying and laying of 63 mm dia (OD-63 mm & ID-51 mm nominal) DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. in the existing trench, complete as required. |
| 7 | Supply of Iron brackets, feeder pillar legs, angles, coupling, other MS items etc. of various sizes i/c fabrication etc. as per site requirement |
| 8 | Laying of one number PVC/XLPE insulated & PVC sheathed armoured / unarmoured AFL / power cable of voltage grade exceeding 1.1 KV but not exceeding 11 KV of size not exceeding 25 sq. mm. in the existing cable duct / masonry trench / RCC /HUME / METAL / GI / HDPE pipes etc. as required as per standard procedure to achieve higher range IR value of the laid loops. |
| 9 | Laying of one number PVC/XLPE insulated & PVC sheathed armoured / unarmoured AFL / power cable of voltage grade not exceeding 1.1 KV of size not exceeding 25 sq. mm. in the existing cable duct / masonry trench / RCC / HUME / METAL / GI / HDPE pipes etc. as required as per standard procedure to achieve higher range IR value of the laid loops. |
| 10 | Supply and testing of V4+ or latest version Single Channel Addressable Switch Devices, IP-68, directly buried under soil / water for selective switching and monitoring of one lamp in constant current series circuits ( AGL curcuits) comptbile for direct operation with the LED fittings and exitings Honeywell make ILCMS etc. complete as required. |
| 11 | Supply of FAA Certified / Complied, Airfield Ground Lighting Cable, 6 sq.mm, 5 KV grade, Single Core, multi stranded tinned copper conductor, tinned copper braid shielded (maximum shield resistance shall not be more than 5 ohm / KM at ambient temperature of 50 degree centigrade), XLPE insulated, and with inner and outer semiconductor, Polyethylene (PE) outer sheathed, Unarmoured Underground Cable compatible to existing ILCMS etc. complete as required.(i) First Year |
| 12 | Supply of FAA Certified / Complied, Airfield Ground Lighting Cable, 6 sq.mm, 5 KV grade, Single Core, multi stranded tinned copper conductor, tinned copper braid shielded (maximum shield resistance shall not be more than 5 ohm / KM at ambient temperature of 50 degree centigrade), XLPE insulated, and with inner and outer semiconductor, Polyethylene (PE) outer sheathed, Unarmoured Underground Cable compatible to existing ILCMS etc. complete as required.(ii) Second Year |
| 13 | Supply of FAA certified / complied 6 sq. mm size, 5 KV grade dry type plug and receptacle of type I, class 'B', Style 3 & 10 primary connector kit with field attachment and suitable for shielded airfield cable with earthing glands, nuts and bolts and IS marked 1X4 sq. mm tinned copper insulated earth continuity wire, copper thimbles and compatible to the existing ILCMS for existing Efla KDL1 joints in the primary circuit etc. complete as required. |
| 14 | Supply of FAA certified / complied 6 sq. mm size, 5 KV grade dry type plug and receptacle of type I, class 'B', primary connector kit with field attachment and suitable for shielded airfield cable, nuts and bolts, copper thimbles and compatible to the existing ILCMS for existing Efla KD500 joints in the primary circuit etc. complete as required. |
| 15 | Supply of FAA certified / complied, type II, class B, style 5 & 12 Secondary connector kit suitable for connection 2X 4 sq. mm multi stranded annealed conductor, unshielded secondary airfield lighting cables for exsitng Efla KD501.1 , KD502.1 secondary cable joints etc. complete as required. |
| 16 | Supply of FAA certified / complied, type II, class B, style 5 & 12 Secondary connector kit suitable for connection 2X 4 sq. mm multi stranded annealed conductor, unshielded secondary airfield lighting cables for exsitng Bildal BE 201B and BE 202B etc. complete as required. |
| 17 | GPS based survey by using total station as and when required basis for light fitting installations as many time as required as per site requirement during the total currency of the contract etc. complete as required. |
| 18 | Supplying and applying non-shrinkable grout compound ( Conbextra GP2 or equivalent) in required proportion for shallow core sealing works on rigid runway / taxiway, including mixing, pouring/injection, surface preparation, finishing, curing, and all materials, labour, tools and plants required for completion of the work as per manufacturer’s specifications and direction of Engineer-in-Charge. |
| 19 | Dismantling of existing 8 inch / 12 inch Inset type runway / taxiway / any AGL light fitting with shallow base by core cutting from bituminous / concrete pavement making it debris free/clean, sealing the cables/pipe ends, cleaning, disposing debris upto 10 KM away and keeping the dismantled materials in safe custody and handing back to AAI at the completion of the project / as decided by the Engineer-In-Charge etc. and disconneting isolating transformers, cables and reconnection of primary cable without IT for continuity of primary circuit etc. complete as required. It includes all precautionary measures to be taken not to interrupt AGL serviceability in other areas where work permit is not granted. |
| 20 | Installation, Testing and Commissioning of inset type Runway/Taxiway light fitting of 8 inch dia. by jig with core cutting at cement concrete/ asphaltic area like runways/ taxiways/ apron /road etc. at the designated locations as per the existing fittings coordinates upto the depth as per OEM of the lights and then upto the existing cable duct / pipe with less size core cutting, arranging power supply with the help of DG sets and water arrangement , removing core and retrieving the pipe at the bottom if exists, cleaning, disposing debris upto 10 KM away, etc. complete as required including plugging the holes with wooden / ply board / PVC as ready for inset fittings installations with aligning and setting after identifying GPS coordinate i/c providing sealing material and installation of Isolating Transformer, connection etc. including supply of all materials for commissioning of the light fitting complete as required except supply of fixture, isolating transformer, plug & receptacles etc. complete as required. |
| 21 | Installation, Testing and Commissioning of inset type Runway/Taxiway light fitting of 12 inch dia. by jig with core cutting at cement concrete/ asphaltic area like runways/ taxiways/ apron /road etc. at the designated locations as per the existing fittings coordinates upto the depth as per OEM of the lights and then upto the existing cable duct / pipe with less size core cutting, arranging power supply with the help of DG sets and water arrangement , removing core and retrieving the pipe at the bottom if exists, cleaning, disposing debris upto 10 KM away, etc. complete as required including plugging the holes with wooden / ply board / PVC as ready for inset fittings installations with aligning and setting after identifying GPS coordinate i/c providing sealing material and installation of Isolating Transformer, connection etc. including supply of all materials for commissioning of the light fitting complete as required except supply of fixture, isolating transformer, plug & receptacles etc. complete as required. |
| 22 | Providing laying and fixing 6 SWG dia G.I. wire on surface or in recess/in existing pipe or along with existing surface/ recess conduit/ pipe submain wiring/cable for loop earthing including termination etc.complete as required as per ADM part-5. |
| 23 | Supply of FAA certified / compliant model, Inset, Bidirectional suitable for ICAO CAT III all weather operation, LED TAXIWAY CENTRE LINE fitting for Straight / Curve section, for ICAO aviation visual aids requirements including installations kits but without shallow base , compatible to the existing ALCMS/ILCMS for the exsting AGL installations comprisning the following TKH fittings etc. complete as required.Model No.: TCL-S-I-31-G00G00-1-1O-1201 (Straight, Green-Green)Model No.: TCL-S-I-31-G00Y00-1-1O-1201 (Straight, Green-Yellow)Model No.: TCC-L-I-31-G00G00-1-1O-1201 (Curve, Left, Green-Green)Model No.: TCC-L-I-31-G00Y00-1-1O-1201 (Curve, Left, Green-Yellow)Model No.: TCC-R-I-31-G00G00-1-1O-1201 (Curve, Right, Green-Green)Model No.: TCC-R-I-31-G00Y00-1-1O-1201 (Curve, Right, Green-Yellow)Straight / curve or narrow / wide beam as per the site requirement. |
| 24 | Supply of FAA certified / compliant model, Inset, uni-directional, Red, suitable for ICAO CAT III all weather operation, STOP Bar light for ICAO aviation visual aids requirements including installations kits but wihout shallow base , compatible to existing ALCMS/ILCMS for the exsting AGL installations comprisning the following TKH fittings etc. complete as required.Model No.: STB-S-I-31-R00000-1-1O-1201 |
| 25 | Supply of FAA certified / compliant model, Inset, uni-directional, suitable for ICAO CAT III all weather operation, Turn Pad Lights for straight / Curve section for ICAO aviation visual aids requirements including installations kits but wihout shallow base , compatible to existing ALCMS/ILCMS for the exsting AGL installations comprisning the following TKH fittings etc. complete as required.Model No.: TCC-S-I-31-G00000-1-1O-1201 (Straight, Left, Green)Model No.: TCC-L-I-31-G00000-1-1O-1201 (Curve, Left, Green)Model No.: TCC-R-I-31-G00000-1-1O-1201 (Curve, Right, Green)Straight / curve or narrow / wide beam as per the site requirement. |
| 26 | Supply of FAA certified / compliant model, Elevated, Uni-directional, Yellow, suitable for ICAO CAT III all weather operation, LED Runway Guard lights along with breakable coupling and base plate for ICAO aviation visual aids requirements including installations kits compatible to existing ALCMS/ILCMS for the exsting AGL installations comprisning the following TKH fittings etc. complete as required.Model No.: RGL-921.891 |
| 27 | Supply of FAA / ICAO compliant Model Elevated, Omni-directional, Blue, suitable for ICAO CAT III all weather operation, LED Taxiway Edge, Apron Edge and LED Turnpad Edge Lights along with breakable coupling and base plate for ICAO aviation visual aids requirements including installations kits compatible to existing ALCMS/ILCMS for the exsting AGL installations comprisning the following TKH fittings etc. complete as required.Model No.: 241.LED-B.B.4.A-6.6A |
| 28 | Supply of FAA certified / compliant model, Inset, bi-directional, suitable for ICAO CAT III all weather operation, LED Runway Centreline (RCL) fitting, for ICAO aviation visual aids requirements including installations kits but without shallow base , compatible to the existing ALCMS/ILCMS for the exsting AGL installations comprisning the following TKH fittings etc. complete as required.Red / Variable WhiteModel No.: RCL-S-I-31-W00R00-1-1O-1201 |
| 29 | Supply of FAA certified / compliant model, Inset, bi-directional, suitable for ICAO CAT III all weather operation, LED Runway Centreline (RCL) fitting, for ICAO aviation visual aids requirements including installations kits but without shallow base , compatible to the existing ALCMS/ILCMS for the exsting AGL installations comprisning the following TKH fittings etc. complete as required.Variable White / Variable WhiteModel No.: RCL-S-I-31-W00W00-1-1O-1201 |
| 30 | Supply of FAA certified / compliant model, Inset, bi-directional, suitable for ICAO CAT III all weather operation, LED Runway Centreline (RCL) fitting,for ICAO aviation visual aids requirements including installations kits but without shallow base , compatible to the existing ALCMS/ILCMS for the exsting AGL installations comprisning the following TKH fittings etc. complete as required.Red / BlankModel No.: RCL-S-I-31-R00000-1-1O-1201 |
| 31 | Supply of FAA certified / compliant model, Inset, Uni-directional, variable White, suitable for ICAO CAT III all weather operation, LED Touch Down Zone (TDZ) fitting, for ICAO aviation visual aids requirements including installations kits but without shallow base , compatible to the existing ALCMS/ILCMS for the exsting AGL installations comprisning the following TKH fittings etc. complete as required.Model No.: TDZ-L-I-31-W00000-1-1O-1201 Model No.: TDZ-R-I-31-W00000-1-1O-1201 Left / Right as per the site requirement. |
| 32 | Supply of FAA certified / compliant model, Inset, Bi-directional, suitable for ICAO CAT III all weather operation, LED Runway Edge light, for ICAO aviation visual aids requirements including installations kits but without shallow base , compatible to the existing ALCMS/ILCMS for the exsting AGL installations comprisning the following TKH fittings etc. complete as required.Model No.: REH-S-I-32-W35W35-1-1O-1201 (Straight, White-White)Model No.: REH-S-I-32-W35Y35-1-1O-1201 (Straight, White-Yellow)Model No.: REH-S-I-32-R35Y35-1-1O-1201 (Straight, Red-Yellow)Model No.: REH-S-I-32-Y35W35-1-1O-1201 (Straight, Yellow-White)Model No.: REH-S-I-32-Y35R35-1-1O-1201 (Straight, Yellow-Red)Left / Right and Yellow / White or White/ White or Red/Yellow or Yellow/Red or White/Yellow as per the site requirement |
| 33 | Supply of FAA certified / compliant model, Elevated, Bi-directional, suitable for ICAO CAT III all weather operation, LED Runway Edge Lights, along with breakable coupling and base plate for ICAO aviation visual aids requirements including installations kits compatible to existing ALCMS/ILCMS for the exsting AGL installations comprisning the following TKH fittings etc. complete as required.Model No.: HIRE-I-R35-Y35-1-1-F-66-GS-2-00-0 (Straight, Red-Yellow)Model No.: HIRE-I-Y35-R35-1-1-F-66-GS-2-00-0 (Straight, Yellow-Red)Model No.: HIRE-I-W35-Y35-1-1-F-66-GS-2-00-0 (Straight, White-Yellow)Model No.: HIRE-I-Y35-W35-1-1-F-66-GS-2-00-0 (Straight, Yellow-White)Model No.: HIRE-I-W35-W35-1-1-F-66-GS-2-00-0 (Straight, White-White)Left / Right and Yellow / White or White/ White or Red/Yellow or Yellow/Red or White/Yellow as per the site requirement |
| 34 | Supply of FAA certified / compliant model, Inset, uni-directional, Green, suitable for ICAO CAT III all weather operation, LED Threshold Lights, for ICAO aviation visual aids requirements including installations kits but without shallow base , compatible to the existing ALCMS/ILCMS for the exsting AGL installations comprisning the following TKH fittings etc. complete as required.Model No.: THR-L-I-32-G00000-1-1O-1201 (Left)Model No.: THR-R-I-32-G00000-1-1O-1201 (Right)Left / Right as per the site requirement. |
| 35 | Supply of FAA certified / compliant model, Inset, Uni-directional, Red, suitable for ICAO CAT III all weather operation, LED Runway End Light fitting, for ICAO aviation visual aids requirements including installations kits but without shallow base , compatible to the existing ALCMS/ILCMS for the exsting AGL installations comprisning the following TKH fittings etc. complete as required.Model No.: RWE-S-I-32-R00000-1-1O-1201 Left / Right as per the site requirement. |
| 36 | Supply of FAA certified / compliant model, Elevated, Uni-directional, Green, suitable for ICAO CAT III all weather operation, LED Threshold Wing Bar Lights, along with breakable coupling and base plate for ICAO aviation visual aids requirements including installations kits compatible to existing ALCMS/ILCMS for the exsting AGL installations comprisning the following TKH fittings etc. complete as required.Model No.: THRW-S-I-34-G00000-3-1O-1200-797-LED-ALeft / Right as per the site requirement. |
| 37 | Supply of FAA certified / compliant Model Inset, Uni-directional, Variable White, suitable for ICAO CAT III all weather operation, LED Approach light fitting, for ICAO aviation visual aids requirements including installations kits but without shallow base , compatible to the existing ALCMS/ILCMS for the exsting AGL installations comprisning the following TKH fittings etc. complete as required.Model No.: APH-S-I-32-W00000-1-1O-1205 (Straight)Left / Right, Centre line / cross bar as per the site requirement. |
| 38 | Supply of FAA certified / compliant Model Inset, Uni-directional, Red suitable for ICAO CAT III all weather operation, LED Side Row light fitting, for ICAO aviation visual aids requirements including installations kits but without shallow base , compatible to the existing ALCMS/ILCMS for the exsting AGL installations comprisning the following TKH fittings etc. complete as required.Model No.: SR-S-I-32-R00000-1-1O-1201 (Straight)Model No.: SR-L-I-32-R00000-1-1O-1201 (Left)Model No.: SR-R-I-32-R00000-1-1O-1201 (Right)Left / Right, Side Row as per the site requirement. |
| 39 | Supply of FAA certified / compliant Model Elevated, Uni-directional, Variable White, suitable for ICAO CAT III all weather operation, LED Approach Lights fitting, along with breakable coupling and base plate for ICAO aviation visual aids requirements including installations kits compatible to existing ALCMS/ILCMS for the exsting AGL installations comprisning the following TKH fittings etc. complete as required.Model No.: APH-S-I-34-W000000-3-1O-1200-797-LED-ALeft / Right and centreline / cross bar as per the site requirement. |
| 40 | Supply of FAA certified / compliant model LED type Inset Unidirectional Rapid Exit Taxiway Indicator light fixture for ICAO aviation visual aids requirements including installations kits but without shallow base , compatible to the existing ALCMS/ILCMS for the exsting AGL installations comprisning the following TKH fittings etc. complete as required.Model No.: RETIL-S-I-31-Y00000-1-00-0000 |
| 41 | Supply of FAA certified / compliant model Inset, uni-directional, Yellow, Medium intensity, suitable for ICAO CAT I & II & III all weather operation, LED Intermediate Holding Position fitting, for ICAO aviation visual aids requirements including installations kits but without shallow base , compatible to the existing ALCMS/ILCMS for the exsting AGL installations comprisning the following TKH fittings etc. complete as required.Model No.: IHP-S-I-31-Y00000-1-00-0000 Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Oct 15, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedNov 05, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 13 daysNov 06, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 14 daysTender Documents
Download All (ZIP) ↓
Disclaimer