Water Resources and Irrigation Boards / Undertakings / PSU Closing in 6 days TDR #58049473

Tender For Renovation Of Control Room At 220Kv Substation Bbmb Charkhi Dadri

Issued by Boards / Undertakings / PSU · Bhiwani, Haryana
Tender Value
Ref. Documents
Estimated cost
Bid Submission
17 Nov 2026
6 days left
EMD
25300
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Bhiwani → Haryana
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Renovation Of Control Room At 220Kv Substation Bbmb Charkhi Dadri

BOQ

Name of Work:- Renovation of Control Room at 220kV Substation BBMB Charkhi Dadri
Sl. No. Item Description
1Providing and fixing tiled false ceiling at height upto 4 mtr of specified materials of size 595x595 mm ( GI Metal Ceiling Lay in plain Tegular edge Global white color tiles of size 595x595 mm, and 0.5 mm thick with 8 mm drop; made of G I sheet having galvanizing of 100 gms/sqm (both sides inclusive) and electro statically polyester powder coated of thickness 60 microns(minimum), including factory painted after bending.) in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 grams/ sqm, both side inclusive) consisting of main \\"T\\" runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200 mm center to center and cross \\"T\\" of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main \\"T\\" at 600 mm center to center to form a grid of 1200x600 mm and secondary cross \\"T\\" of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main \\"T\\" runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanised butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all Tsections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer-in-charge. As per Pb CSR ref.13.80
2Dismantling of floor tiles at any floor of the building, laid in cement mortar including dismantling of cement concrete base and disposal of malba at a suitable place within a distance of 100 Mtrs of the complex complete in all respect As per Pb CSR ref.30.95
3Cement concrete 1:2:4 (a) With stone ballast or shingle (ii) mixing by mechanical means using concretemixer volumetric type As per Pb CSR ref.10.13aii
4Providing and laying vitrified floor tiles of different sizes in light colour shades made using Double Charge technology (thickness to be specified by the manufacturer) with water absorption’s less than 0.08% and conforming to IS : 15622 of approved make in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement: 4 fine sand), complete. (a) Size 600x600 mm As per Pb CSR ref.14.113(a)
5Providing and fixing aluminum work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/appropriate z sections and other sections conforming to Is: 733 and IS : 1285 of Jindal, Hindalco, Mahavir or equivalent make approved by Engineer in Charge , fixed with rawl plugs and screws or with fixing clips, or with expansion hold fasteners including necessary filling up of gaps at junctions, at top, bottom and sides with required PVC Plug/neoprene felt etc. aluminum sections shall be smooth, rust free, straight, mitered and jointed mechanically wherever required including cleat angle, aluminum snap beading for glazing/paneling, C.P.brass/stainless steel screws, all complete as per architectural drawings and the directions of Engineer-InCharge. (Glazing and paneling to be paid for separately) : As per Pb CSR ref.17.45
6(a) For fixed portion and chawkhats As per Pb CSR ref.17.45a
7(b) For shutters of doors, windows & ventilators including providing and fixing hinges/pivots and labour for fixing of fittings wherever required including the cost of PVC Plug / neoprene gasket required As per Pb CSR ref.17.45b
8Providing and fixing glazing in aluminum door, window, ventilator shutters and partitions etc. with PVC Plug/ neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminum snap beading shall be paid in basic item) (i) Float glass panes of 5 mm thickness As per Pb CSR ref.17.47i
9Providing and fixing 12 mm thick frameless toughened glass door shutter of approved brand and manufacture, including providing and fixing top & bottom pivot & double acting hydraulic floor spring type fixing arrangement and making necessary holes etc. for fixing required door fittings, all complete as per direction of Engineer-in-charge As per Pb CSR ref.17.101
10Providing and fixing double action hydraulic floor spring of approved brand and manufacture IS : 6315 marked, for doors including cost of cutting floors as required, embedding in floors and cover plates with brass pivot and single piece MS sheet outer box with slide plate and with stainless steel cover plate etc. complete as per the direction of Engineerin-charge. As per Pb CSR ref.17.48
11Removing Doors and Windows (Steel or wood) with chowkhats by making recesses in walls when the wall is not to be dismantled. As per Pb CSR ref.8.26
12(a) Doors of area 3 sqm and below. As per Pb CSR ref.8.26 a
13(b) Windows of area 3 sqm and below As per Pb CSR ref.8.26 b
14Dismantling aluminium/ Gypsum partitions, doors, windows, fixed glazing and false ceiling including disposal of unserviceable material and stacking of serviceable material within 50 meters lead as directed by Engineer-in-charge As per Pb CSR ref.8.44
15Cost of aluminum fittings complete for doors, windows such as tower bolts, handles,Stoppers and screw etc. for these fittings (Excluding sliding bolt) (i) For shutter area up to 0.50 sqm As per Pb CSR ref.17.23 (ii)
16Providing Polyester Powder coating 50 micron any coloured specified to alumnum section of various sizes including carriage of material from market to workshop & workshop to site of work. As per Pb CSR ref.18.48
17Painting with acid proof paint of approved brand and manufacture to give an even shadetwo or more coats As per Pb CSR ref.16.64
18Preparation of plastered or concrete surface for painting (including sand papering the surface) using ready mixed cement based wall putty by applying two or more coats to get required finish As per Pb CSR ref.16.65
19Finishing walls with acrylic smooth exterior paint of required shade with two or more coats applied @ 1.67 litre/10Sqm over and including base coat of water proofing Cement Paint applied @ 2.20 Kg/10 Sqm As per Pb CSR ref.16.59
20Distempering with Acrylic washable oil bound distemper (of approved manufacture) two or more coats on old distempered work when shade is changed As per Pb CSR ref.16.12
21Scraping As per Pb CSR ref.8.31
22(a) Cement plaster As per Pb CSR ref.8.31 a
23(c) Cement plaster As per Pb CSR ref.8.31 c
24Providing and laying resilient vinyl sheet floor covering 2 mm thick, having a vinyl plastic wear layer with backing intended for use in light commercial and residential buildings, duly fixed to the base floor using adhesive as approved by the manufacturer. As per Pb CSR ref.14.99
25Providing and fixing 10mm thick acid and/or alkali resistant tiles 300 mm x 300 mm of approved make and colour using acid and/or alkali resisting mortar bedding and joints filled with acid and/or alkali resisting cement as per IS : 4457 complete as per the direction of Engineer-in- Charge, in flooring or in dado / skirting on a bed of 12 mm thick mortar 1 : 4 (1 acid proof cement: 4 coarse sand). As per Pb CSR ref.14.130
26Dismantling brick work tile, masonry or tile lining (b) In cement As per Pb CSR ref.8.5 b
27Cement pointing 1:3 deep variety As per Pb CSR ref.15.60
28Providing and fixing bright finished brass 100 mm mortise latch and lock with 6 levers and a pair of lever handles with necessary screws etc. complete (best make of approved quality). As per Pb CSR ref.17.22 iv
29Plastering on underside of ceiling 10mm thick cement plaster 1:3 As per Pb CSR ref.15.43
30Providing and fixing chicken mesh for brick work and RCC junction of galvanized low carbon wire, annealed wire of diametre 0.6 to 2.0mm distance between the faces of the hexagon 13 to 50mm complete in all respect. As per Pb CSR ref.15.79
31RECESSED HGW CONDUIT PIPE WIRING SYSTEM WITH MODULAR SWITCHES: Wiring in PVC insulated copper conductor single core FR cable (ISI marked) overall 1.5sq. mm, 1100volts grade to be laid in heavy gauge welded conduit pipe 20mm/ 25mm dia (1.6mm thick) ISI Marked, recessed in wall etc., complete with powder coated/anodized concealed metal boxes (1.6mm thick with Brass lugs) required for suitable number of modules (Modular accessories) for having Step type electronic fan regulators (two module) 100watts, bell push, 6Amp. 2/3 universal socket (shuttered), 16/20Amp. combined/ universal Socket (shuttered), 6/10Amp. Switches, 16/20Amp. switches with indicator etc. and covered with Frame Plate etc., PVC connector (For Fan Box and Call Bell), PVC Bush, Steel Hooks, Sheet metal fan box (1.6mm thick shape hexagonal), CI Circular junction Boxes (Four way 1½\\" deep for walls and 3\\" deep for ceiling), bonding to earth with PVC insulated copper conductor single core FR cable (ISI marked) 1sq. mm, 1100volts grade (For 6Amp. wall socket & plug control point) and other petty material etc. including the cost of above material, cutting and filling up of chases (with finishing the surface):- As per Pb CSR ref.34.01
32Wiring fan point (With fan box) As per Pb CSR ref.34.01(i)b
33Wiring light point As per Pb CSR ref.34.01(ii)
34Wiring 6Amp. wall socket point As per Pb CSR ref.34.01(iv)
35Wiring 16/20Amp. power plug control point As per Pb CSR ref.34.01(vi)
36RECESSED AIR CONDITIONER SUPPLY TERMINAL POINT (USED FOR HGW, PVC CONDUIT & HDPE PIPE WIRING SYSTEM WITH MODULAR ACCESSORIES): Wiring air conditioner supply terminal point recessed in wall etc., complete with powder coated / anodized concealed metal boxes required for suitable number of modules (Modular accessories) for having 25Amp. combined/ universal Socket (shuttered) and modular motor starter 25Amp. (2Module), covered with Frame Plate and other petty material etc. including the cost of above material, cutting and filling up of chases (with finishing the surface): Wiring AC supply terminal point having 1No. 25Amp. universal Socket (shuttered) erected at AC height and 1No. Motor starter 25Amp. erected at switchboard height.As per Pb CSR ref.34.01(ix)
37RECESSED COMPUTER SUPPLY TERMINAL POINTS (USED FOR HGW, PVC CONDUIT & HDPE PIPE WIRING SYSTEM WITH MODULAR ACCESSORIES): Wiring Computer supply terminal points recessed in wall etc., complete with powder coated / anodized concealed metal boxes required for suitable number of modules (Modular accessories) for having 6Amp. 2/3 universal socket (shuttered), 16/20Amp. combined/ universal Socket (shuttered), 6/10/16/20Amp. Switches and blanking plate etc., and covered with Frame Plate and other petty material etc. including the cost of above material, cutting and filling up of chases (with finishing the surface):- Wiring Computer terminal point having 3 Nos. 6Amp. 2/3 universal socket (shuttered), 1No. 16/20Amp. universal Socket (shuttered), 2Nos. 16/20Amp. switch with indicator and 2Nos. blanking plate (Modular accessories).As per Pb CSR ref.34.01xC
38RECESSED TV, TELEPHONE & NETWORKING SOCKETS OUTLET POINTS (USED FOR HGW, PVC CONDUIT & HDPE PIPE WIRING SYSTEM WITH MODULAR ACCESSORIES): Supply and erection of TV socket, Telephone socket and Networking socket points in powder coated/anodized concealed metal boxes recessed in wall required for suitable number of modules (Modular accessories) for having TV sockets, Telephone sockets RJ11 & Networking socket RJ45 (one module), covered with Frame Plate and other pettymaterial etc., including the cost of above material, cutting and filling up of chases (with finishing the surface):- As per Pb CSR ref.34.01
39Wiring TV socket point (one module) As per Pb CSR ref.34.01 xi(a)
40Wiring Telephone socket point RJ11 (one module) As per Pb CSR ref.34.01 xi(b)
41Wiring Networking socket point RJ45 (one module) As per Pb CSR ref.34.01 xi(c)
42Dismantling PVC Flooring from floor (N.S. Item) Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 58049473
AUTHORITY Boards / Undertakings / PSU
TENDER VALUE Ref. Documents
LAST DATE 17-11-2026
Authority
Authority Name Bhakra Beas Management Board
Work Description Tender for Renovation Of Control Room At 220Kv Substation Bbmb Charkhi Dadri
Basic Detail
Tender No ENIT07/O M BWN/2026-27
Bidding Type Tender
Location
City Bhiwani
State Haryana
Key Dates
Publish Date 15 Oct 2026
Submission Date 17 Nov 2026
Open Date 18 Nov 2026
Finance
Tender Value Ref. Documents
Tender Fee Ref. Documents
EMD 25300
Exemption Not Available
Document List
89bb0d5f-822a-4ab5-a90d-30ad9fb34a4a.html
BOQ_343301.xls
nitdocument.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Oct 15, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Nov 17, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 6 days
Nov 18, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 7 days

Tender Documents

Download All (ZIP) ↓
html

89bb0d5f-822a-4ab5-a90d-30ad9fb34a4a.html

xls

BOQ_343301.xls

pdf

nitdocument.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender