Defence Statutory Bodies & Commissions/Committees Closing in 4 days TDR #58048651

Tender For Provn Of 02X Toilet Blocks 01 X Each In 734 & 736 Tpt Wksp Of 39 Eme Bn (Tpt) And special Repair To Roof Treatmennt To Govt Or Md Accn Bldg No Np-55, Np-56, Np-57 And Np-58 At Jagdish Vihar Of 14 Ew Bn Under Ge (West) Pathankot

Issued by Statutory Bodies & Commissions/Committees · Pathankot, Punjab
Tender Value
30.94 Lakhs
Estimated cost
Bid Submission
05 Nov 2026
4 days left
EMD
61880
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Pathankot → Punjab
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Provn Of 02X Toilet Blocks 01 X Each In 734 & 736 Tpt Wksp Of 39 Eme Bn (Tpt) And special Repair To Roof Treatmennt To Govt Or Md Accn Bldg No Np-55, Np-56, Np-57 And Np-58 At Jagdish Vihar Of 14 Ew Bn Under Ge (West) Pathankot

Corrigendum

Sr No Corrigendum Date Corrigendum Type New Submission Date
1 22-Oct-2026 Corrigendum01 Other 05-Nov-2026

BOQ

Name of Work:- PROVN OF 02X TOILET BLOCKS 01 X EACH IN 734 & 736 TPT WKSP OF 39 EME BN (TPT) AND SPL REPAIR TO ROOF TREATMENNT TO GOVT OR MD ACCN BLDG NO NP-55, NP-56, NP-57 AND NP-58 AT JAGDISH VIHAR OF 14 EW BN UNDER GE (WEST) PATHANKOT
Sl. No. Item Description
1Sch 'A' Part-I B/R PortionSurface excavation in any type of soil n.exc (not exceeding) 30 cm deep and averaging 15cm deep and getting out complete.all as specified and as directed by Engr-in-Charge.
2Excavating over areas, n exc 1.5 m deep and getting out in loose / soft soil complete all as specified and directed by Engr in Charge.
3Excavating in any type of soil in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out complete all as specified and directed by Engr in Charge.
4Returning filling in including spreading leveling, watering and well ramming in layers not exc 25 cm in soft/loose soil complete all as specified and directed by Engr in Charge.
5Removing excavated materials( soil) obtained from excavation to a distance not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and directed by Engr in Charge.
6Plain Cement Concrete Type D2 1:4:8 (using 40 mm graded stone aggregate) in foundations, filling and mass concrete complete all as specified and directed by Engr in Charge.
7M&L for Hardcore broken stone or boulders of gauge n exc. 63 mm, deposited, spread and levelled in layers n exc. 15cm rammed to a true surfacecomplete all as specified and directed by Engr in Charge.
8M&L for 100 mm thick Cement concrete type D- 2, 1:4:8 (40mm graded aggregate) as in sub floor, Sub bases, floors and pavings etccomplete all as specified and directed by Engr in Charge.
9M&L for 75 mm thick Cement concrete type D- 2, 1:4:8 (40mm graded aggregate) as in sub floor, Sub bases, floors and pavings etc complete all as specified and directed by Engr in Charge.
10M&L for 25 mm thick Cement concrete type B-12, 1:2:4 (20mm graded aggregate) as in sub floor, Sub bases, floors and pavings etc to receive the tile complete all as specified and directed by Engr in Charge.
11M&L for 75 mm thick Cement concrete type D- 2, 1:3:6 (40mm graded aggregate) as in Plinth protection etc complete all as specified and directed by Engr in Charge.
12Formwork to sides of concrete foundations, footings, bases of columns, rafts raft beams, sides and soffits ( if any ) of foundation and plinth beams; and similar work; vertical or batter, finished rough surfaces of concrete, complete all as specified and directed by Engr in Charge.
13Formwork to Square, rectangular or polygonal sides of pillars, posts, struts, piers, columns and stanchions complete all as specified and directed by Engr in Charge.
14Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping) complete all as specified and directed by Engr in Charge.
15Formwork to sides and soffits of floor or roof beams,Lintel beam,Plinth beam haunch ings, girders, bressummers, lintels, cantilevers, shelves, chhajja etc including sup- ports, overhangs, etc. also splays between floors and beams, etc.complete all as specified and directed by Engr in Charge.
16M&L TMT bars 6mm to 8 mm cut to length, bent to shape required including bending, cranking etc and binding with and including MS wire (annealed) not less than 0.9mm dia, complete all as specified and directed by Engr in Charge.
17M&L TMT bars 10mm dia and over cut to length, bent to shape required including bending, cranking etc and binding with and including MS wire (annealed) not less than 0.9mm dia, complete all as specified & directed by Engineer-in- charge.
18M&L Reinforce cement concrete M-25 (Designmix) Foundations, including rafts, footings, bases for columns, etc.; basement slabs, under-reamed piles and mass concrete complete all as specified and as directed.
19M&L Reinforce cement concrete M-25 (Design mix) as in Slabs supported on walls, beams and columns in floors, roof slab, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and as directed.
20M&L Reinforce cement concrete M-25 (Design mix) as in Beams,Plinth/Roof beam cantilevers,chhajja, bressummers,lintels over 1.5m span complete all as specified and as directed.
21M&L Reinforce cement concrete M-25 (Design mix) as in Columns, pillars, piers, posts and struts complete all as specified and as directed.
22M&L for brick work with sub class 'B' Bricks (using old size bricks) straight or curved on plan exc 6m mean radius, built in CM 1:6, complete all as specified and as directed.
23M & L for Brickwork with sub class B bricks straight or curved on plan to any radius in half brick thick walls, built in CM 1:4 complete all as specified and as directed.
24M&L Rendering 10mm thick on fair faces of brick work or concrete surfaces wall in cm 1:6 to be finished even and smooth (without using extra lime or cement) complete all as specified and as directed.
25M&L Rendering 15mm thick on fair faces of brick work or concrete surfaces of wall in cm 1:4 to be finished even and smooth (without using extra lime or cement) complete all as specified and as directed.
26M&L Rendering 5mm thick on fair faces of brick work or concrete surfaces in cm 1:3 to be finished even and smooth (without using extra lime or cement) complete all as specified and as directed.
27Supply only `Liquid Water Proofing Compound complete all as specified and directed by Engr-in-charge.
28M&L for preparation of newly plaster surfaces of walls and applying two coats of oil bound distemper over a priming coat of chalk whiting, on plastered surfaces, preparatory to distempring complete all as specified.
29M&L for preparation of newly plaster surfaces of walls and applying two coats of cement base paint over a priming coat of alkalies resistance priming paint complete all as specified.
30M&L for preparation of newly plaster surfaces of ceiling and applying three coats of white wash over ceiling complete all as specified and as directed.
31S&F Coloured Non - skid Ceramic tiles 7 to 8 mm thick area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match incl 20 mm thick screed bed in CM 1:6 complete all as specified.
32S&F Coloures Glazed ceramic tiles in vertical surface 350x 250x 7-8 mm/ 450X 350X 7-8 mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match including rendring of 10mm thick cement plaster in CM 1:3 on fair faces of brick work or concrete surfaces complete
33M&L for 16-18 mm thick Granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, win dow-cills, cooking plat forms and like in cement mortar (1:4) including point ing in white cement (1:2) using marble dust with admix ture of pigment to match with shade of granite complete all as specified and as directed.
34S&F of 15mm dia medium grade GI tubing with all fitting and fixed to wall, ceiling or laid in floors etc complete all as specified and as directed.
35S&F 20mm bore Steel water tubing 'medium grade', galvanised with all fittings like elbow, tee, socket, bend etc and fixed to wall, ceiling or laid in floor complete all as specified and directed.
36Cutting chases in brick walls, pinning in, making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, shelves, lintels, etc, and cutting chases for concealed water tubing or conduit wiring, etc and making good, cutting not exceeding 10cm girth complete all as specified and directed
37S&F of vitreous china wash down water closet pan (Pedestal Pattern ) white including fixing bolts, plastic water closet seat, white, closed pattern, solid type with flat bottom, and cover and mild steel chromium plated hinging device and including 'P' / 'S' trap complete and including making good to floor to match with adjoining surfaces complete all as specified and as directed
38S&F of vitreous China squatting pan, ‘Orissa’ pattern, size 580 x 440 mm white, with integral foot rests including provision of lime concrete bedding, making good to floor and all fittings including 'P / 'S' trap (excluding flushing cistern and flush pipe) complete all as specified and as directed.
39S&F of counter below type Wash basins, Vitreous China (flat back type) 550 x 400mm and 32 mm waste coupling,75 cm long PVC flexible waste pipe etc complete all as specified and as directed.
40S&F for Viterous China urinal, half stall type, white complete including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and waste coupling fit to urinal and including 60mm long brass screws, pointing around urinal back in cement including waste / Urinal pipe complete all as specified and as directed.
41S&F Urinal spreader of PTMT any colour for fixing with 15 mm dia pipe. (Minimum weight 60gms) complete all as specified and as directed.
42S&F Vitreous china urinal partition white of size 310x700 mm complete all as specified and as directed.
43S&F of brass chromium plated tubular towel rail 20mm dia 'D' type 60cm long between flanges complete all as specified and as directed.
44S&F of PVC 10 ltrs capacity valveless symphonic action type low level flushing cistern including flush pipe, cantilever brackets incluiding taking down existing cistern etc complete all as specified and as directed.
45S&F of PVC connections 15mm size with PTMT nuts of length 450mm complete all as specified and as directed.
46S&F of Pillar taps fancy type cast copper alloy chromium plated with capstan head without letter Hot or Cold water screwed down for 15 mm dia iron pipe complete all as specified and as directed.
47S&F of 15mm bore dia of pipe bib taps cast copper alloy, fancy type chromium plated, with capstan head screwed down, high pressure screwed for iron pipe or brass ferrule complete all as specified and as directed.
48S&F of stop valve / angle cock fancy type cast copper alloy chromium plated with long shank and cup(concealed type) capstan head serewed down, high pressure for 15 mm dia iron pipe complete all as specified and as directed.
49S&F of brass chromium plated health faucet with 1m long PVC tube & wall hook. screwed for 15mm dia bore iron pipe or 2 in one tap complete all as specified and as directed. Make: ALD -563 Jaquar or equivalent in any of the make mentioned in list of product complete all as specified and as directed.
50S&F of CP Grating with hole /with out hole of dia 125 mm complete all as specified and as directed.
51S&F Gun-metal, globe or gate valves 15mm bore, with iron wheel head, screwed both end for iron pipe
52S&F 600 x 450 mm of looking mirror bevelled edges of selected quality glass mounted on 6mm commerical ply or AC building board with aluminium frame around and fixed to wooden plugs with CP brass screws complete all as specified and as directed.
53S&F of factory made solid panel PVC door shutter 30mm thick (style) consisting of frame made out of MS tubes for top and bottom rails MS frame shall be coucred with heat moulded wood grain printed PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and wood grain printed PVC sheet for top rail, lock rail & bottom rail on either side as gap insert for top rail bottom rail panelling of wood grain printed PVC sheet to be fited in the MS frame welded/seald to the stiles & rails with suitable PVC sheet beading and jointed together with solvent cement suppling & fixed in the framed site as per specification & drawing complete all as specified and as directed.
54S&F of PVC door frame of size 50mmx47mm made out of 5mm wood grain printed PVC sheet reiforced with MS squre tube as per specification and drawing complete all as specified and as directed.
55S&F steel window/Ventilator factory made box type and shutter (double shutter) with sash bar made out of section using flash butt welding, hinges shall be provided to both shutters complete including all fittings including grills made out of 10 mm dia round bars glazing with 3 mm thick oridinary glass, guaging (wire mesh stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.18mm and fixed with stainless steel wire staples or using metal nut and bolts ) and two coat synthetic enamel paint over and including a coat of red oxide primer all as per drg No CEPZ/ TD/032/13 Sheet 1/2 complete all as specified and directed.
56S&F 250mm long Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed
57S&F of aluminium anodised barrel tower bolts of extruded section 150mm long complete all as specified and as directed.
58S&F of 150mm size,extruded aluminium alloy handles, fabricated type anodised complete all as specified and as directed.
59S&F of 100 mm size SS butt hinges with galvanised mild steel hinges complete all as specified and as directed.
60S&F of 110 mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls complete all as directed.
61S&F of 110 mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints laid in trenches complete all as directed.
62M&L for 300mm bore Reinforced concrete pipes, class NP3, laid and jointed complete with collars complete all as specified and as directed.
63M&L for Concrete bed type D-2 1:4:8 to drain pipes including packing under, and haunching against the sides of pipes after they are laid and tested;complete all as specified and as directed.
64S&F of 110 mm bore PVC (SWR) bends complete all as specified and as directed..
65S&F of 75/100mm PVC(SWR) floor trap plain with grating incl jointing with solvent cement complete all as specified and as directed.
66S&F of 110 mm bore PVC (SWR) cowl complete all as specified and as directed..
67S&F of 110 mm bore PVC (SWR) accessible door bends complete all as specified and as directed..
68S&F of PVC (SWR) 110mm bore 'T' equal or unequal complete all as specified and directed.
69S&F Rotational moulded polyethlene water storage tanks three layers of 500 ltrs capacity ISI marked (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part I including 20mm Ball valves high pressure of PTMT with epoxy coated Aluminium rod & high-density plastic bal screwed for iron pipe and fixed. (Minimum weight 20mm-210 gms and fixing of inlet, outlet & over flow pipe etc complete all as specified and as directed.
70M&L for Machine pressed precast concrete interlocking paver block glossy finish any shape and size confirming to IS 15658-2006 of 60 mm thickness M-35 Grade including 25mm thick compacted bed of coarse sand cushion , compacting and proper embedding/ laying of inter locking paver blocks with grey cement and pigment into the sand bedding layer , filling the joints with fine sand and cutting of paver block as per required size and pattern, finishing and sweeping extra sand; complete.all as specified and as directed by Engr-in-Charge.
71M&L for PCC 1:2:4 type C-1 (using 20mm graded stone aggregate) as in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs not provided for water troughs and the like including weathering, slightly rounded or chamfered angles and throating, complete all as specified and directed by Engr-in-charge.
72M&L liquid water proofing treatment to RCC roof slab including dismantling of existing roof treatment of any description such as worn-out tar felt, debris, mortar of any description & any thickness, surface cleaning of all foreign material such as shrubs/roots, fungus, moss, dust including plaster, APP membrane etc. including disposal of debris out of MoD land : (a) Prepare the surface by cleaning the surface and making free of dirt, foreign particles, laitance followed by grinding all protrusions to make surface modulated, thereafter, inspection for cracks on the surface caused by thermal expansion, contraction. Cutting the grooves with suitable cutter machine in \\"V\\" groove filled with Repair mortar/micro concrete/General purpose grout as recommended proportionally as per recommendation of manufacturer. Making of Gollas at all the corners with Polymer modified mortar (1:4 Cement: sand with acrylic polymer 3.5% by weight of cement) complete all as specified.(b) Laying 10mm thick rendering in Cement mortar 1:3 with liquid water proofing compound (as per manufacturer’s instructions) on fair faces of concrete roof surfaces, finished even and fair to receive treatment on roof Complete (c) Supplying and applying High performance Hybrid Polyurea waterproofing coating spray/hand applied liquid membrane with following specifications: (i) Elongation of range 400% to 600%(ii) Tensile strength of 8-12 N/mm2.(iii) Crack bridging ability of 3.00-4.00mm.(iv) Hardness (Shore 'A' ASTM D2240) of range 50-70. The application shall include epoxy primer application in ratio 1:1 (resin: hardener) with 100% water dilution and laying of fiber mesh 1.5 mm thick wave in leno pattern laying weight 4.5gm/Sqm and painting it properly with overlap of 50 mm, and allowing it to dry before application of Hybrid polyurea in two coats in 6 hrs interval to achieve total min thickness 1 to 1.50mm. The application/ treatment shall be carried out by authorized rep of approved specialist firm/manufacturer.
73Note:- (i) The defect liability period of water proofing treatment to RCC roof slab including sunken floor shall be 10 years and the contractor shall be responsible to keep the entire building(s) free From leakage/seepage for a period of 10 years after certified date of completion. The contractor may obtain a similar guarantee from the specialist firm engaged by him for the purpose (ii) Work to be carried out by authorized applicator and as per manufacturer’s instructions.(iii) Providing test with filling of water for continuous 48 hours if there is any leakage than entire treatment will be done again by contractor without any cost.(iv) The rate includes for filling cracks in existing roof with epoxy cement mortar using suitable bonding agent before laying cement plaster.(v) Material shall be purchased directly from the Company’s Authorised Dealer only. No material procured from any other source or prior to the issue of the Work Order shall be permitted for use.All the purchase vouchers for the quantities incorporated in the contract should be verified and defaced by Engineer-in-Charge and same should be kept in record. The purchase vouchers of all the materials for entire quantity should be recorded in Measurement book as ‘not to be abstracted’.(vi) The contractor will be procured 50% of quantities immediately after placing of WO. The remaining 50% quantities will be procured in one week advance before consumption/competition of earlier quantities (first 50% material). All the material shall be kept in custody of the contractor and in double lock & Key system. The one key shall be with the Engineer-in-Charge and other shall be with the contractor’s representative.(vii) Stored material will be issued by the contractor to applicator in consultancy with Engineer-in-Charge on daily basis.(viii) The contractor shall submit a valid Memorandum of Understanding (MoU) executed with any one of the approved brands(ix) Warranty: One year for defects due to workmanship.”
74Taking up or down 20mm bore steel tubing / PPR Pipe and including cleaning for refixing or removal to store complete all as directed
75M&L for 3- layer PP-R Polypropylene 20 mm dia random copo lymer) conceal ed pipes SDR 7.4 (PN16) UV stabi lized and antimi crobial fusion welded having thermal stability for hot & cold water supply all PP-R plain & brass threaded polypropylene random fittings laid in trenche
76M&L for Making connection of PP-R distribution branch with PP-R main of following sizes 16 to 40 mm dia by providing and fixing tee including cutting and making fusion joint etc.
77S&F in Repairs 15 mm dia ball valves high pressure of PTMT with epoxy coating Aluminium rod and high density plastic ball screw for pipe and fixed complete all as specified and directed.
78Dismantling of 1000 ltr water storage tanks and removed to store complete all as specified.
79S&F rotational moulded PVC water storage tank three layers of 1000 ltrs capacity ISI marked (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part I including inlet & outlet tank nipple 20 mm thick ball valve high pressure of PTMT with epoxy coated aluminium rod and high dinsity plastic bal screwed for iron pipe and fixed ( Minimum weight 20mm-210 gms including dismantling of old broken water tanks and refixing of inlet , outlet & over flow pipe etc complete all as specified and directed.
80Disconnecting existing tanks, setting aside (or lowering if required) for repairs, cleaning, etc. and hoisting and reconnecting and re-fixing in position (Cleaning repairing etc. measured separately) exc 500 and n.exc 1000ltr incl all fittings
81Taking up or down 100/110 mm PVC pipe and including cleaning for refixing or removal to store complete all as directed
82S&F PVC (SWR) 100/110mm bore single socketed pipes in any length with rubber ring joints fixed to wall with pvc clamps complete.
83Demolition of Brick work or stone boulder masonry, built in cement mortor or cement lime mortar.
84M&L for brick work with fly ash modular bricks straight or curved on plan exc. 6m mean radius built in CM 1:6 complete all as specified
85Taking down cement plaster or cement lime plaster of any description including racking out joints and hacking for key and scrubbing down with water etc.
86M&L for Rendering 15 mm thick cement plaster on fair faces of brick work/concrete in cement mortar 1:6, with water proofing compound finished even and smooth without using extra cement.
87Supply only integral water proofing compound
88M&L for rendering 10mm thick cement plaster 1:4, incl finishing even and smooth without using with out extra cement on internal faces.
89M&L for cement plaster 1:3, 5 mm thick incl finishing even and smooth without using extra cement on ceiling.
90M&L for preparation of two coat of OBD over a coat of chalk whiting over one coat of 1.5 mm thick wall care putty on plastered surfaces of primer on newely plastered surfaces of walls complete all as directed
91M&L for new exterior painting work and making good/smooth the surface with wall putty with silicon additives and sanding thes surface for removal of loose particles and applying one coat of SmartCare waterproof primer (Damp Prime Suprema) on walls and chajjas with 10% of dilution of water and applying two coats of 100% acrylic smooth emulsion exterior grade with silicon additives and anti-algal properties (Apex Ultima Suprema). complete all as sepcified and directed.Note: All treatment shall be doneby authorised OEM with the help of mechanical means.
92M&L for three coats of white wash to ceiling surfaces including preparation of new surfaces complete all as specified
93M&L for exterior painting work including complete removal of existing treatment and rubbish material till top surface of existing plaster and crack filling with crack seal upto 3mm where required and making good/smooth the surface with wall putty with silicon additives and sanding thes surface for removal of loose particles and applying one coat of SmartCare waterproof primer (Damp Prime Suprema) on walls and chajjas with 10% of dilution of water and applying two coats of 100% acrylic smooth emulsion exterior grade with silicon additives and anti-algal properties (Apex Ultima Suprema). complete all as sepcified and directed.Note: All treatment shall be doneby authorised OEM with the help of mechanical means.
94M & L for preparation of old surfaces by complete removal of existing treatment of painted walls incl pillar etc. by mechanical equipments like electric wall sander/water jet machine and applying cement based putty of 1 mm thickness over plastered surface to prepare the surface even and smooth and applying two coat of distemper with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gms/litre, of approved manufacturer, of required shade and colour over a coat of alkali resistant primer complete, by mechanical means as per manufacturer's specification all as specified and as directed.
95M&L for complete removal of existing treatment on ceiling and applying two coats of oil bound distemper over a coat of alkali resisitant primer complete all as specified and directed.
96Hacking out old broken glass (any thickness, size, quality or description) from wooden frames or stone, concrete or brick surrounds, glazed with putty or fixed with beads (ht up to 15 m)
97S&F plain sheet glass ordinary quality and glazing with oil putty /wdn beads in square n.exc.0.50sqm in each pane 3 mm thick plain glass on new or old windows all as specified and directed by Engineer-in-Charge.
98M&L for preparation of old painted wood or wood based surfaces of any description over 10cm width or girth and applying one coat of Synthetic enemal paint, complete all as specified and directed by Engr-in-Charge. (Note : Work to be carried out from ground floor to fourth floor of bldg height)
99M&L for preparation of old painted steel surfaces of any description over 10cm width or girth and applying one coat of Synthetic enemal paint, complete all as specified and directed by Engr-in-Charge.
100Sch 'A' Part-I E/M PortionM&L Point wiring with 1.5 Sq. mm (nominal area) FRLS PVC insulated and unsheathed multistranded copper conductor cable 1100 Volts grade drawn through and incl PVC rigid concealed conduit (ISI Marked) suitable size with all accessories incl sheet steel/ CI terminal box of adequate size including 3mm thick hylem/masonite sheet including 1.5 Sqmm FRLS PVC insulated unsheathed copper conductor multistranded cable of green colour as earth conductor connected to common earth dolly complete all as specified and directed for one light / fan point controlled by one switch 5 Amp, SP, one way, 240 Volts.Note: 1. Connections of cable with MCBs/Switch Sockets shall be done through proper size copper/brass thimbles. 2. Conduit shall be fixed on surface of roof with necessary saddles where concealing of conduit in not feasible. 3. Proper colour code will be used for wiring as per the electrical rule and as directed.
101All as per Srl item No 99 here-in-before but for one 5 pin 5 Amp socket outlet point on independent board controlled by one switch SP, one way 5 Amp, 240Volts.
102S&F socket outlet 2 in 1, 3 pin 5 amps flush type 240 volts complete all as specified and directed.
103S&F mirror light 10 Watt LED 2' length prewired with all accessories including lamp and connected electrically to ceiling rose using PVC insulated and overall sheathed flexible copper conductor 3core cable of size 0.50Sqmm.
104M & L for ceiling rose, PVC/Polycarbonate, insulated body, surface Bakelite 65mm dia three terminals all as specified and as directed.
105S&F 22W surface / wall mounted LED fitting, extruded aluminium housing with Polycarbonate diffuser and inbuilt ind electronic driver with high efficiency long life, CRI = 80 (Minimum), PF > 0.95, luminous efficacy > 110 lumens/Watt operating voltage 140V-240V, CCT (K) > 6500, THD < 10% complete with all accessories internally prewired and including connecting up with flexible copper conductor cable of suitable size from ceiling rose to connector of LED fitting complete all as specified and directed.
106M & L for providing/ cutting the round/ square hole of required size in wall finishing the distrubed surfaces as per existing finishes complete all as spd and S&F MS ventilating fans Single phase, 230 volts 300 mm or 12” H.D EX Fan (900 RPM) complete and supply and grouting the ragged bolts in wall, fixing the frame on the exhaust side (outer surface of the wall) and connecting with and including suitable size PVC insulated copper cable from ceiling rose to exhaust fan motor and writting MES No. with black synthetic enamel paint 2.0 cm high complete all as spd and directed by Engr-in-charge.
107S&F of sheet metal enclosure MCB distribution board, double door with IP-43 protection single phase 240 volts 4 way, including suitable size copper bus bar and neutral link fixed flush in wall including chases wall for fixing DB and making good the distributed wall surfaces to match with existing specification complete all as specified and directed by Engr-in-charge.
108S&F MCB SP 240V, 50Hz, 10 KA, 'B' curve of rating 6 to 32 Amp all as specified and directed.
109S&F MCB SPN 240V, 50Hz, 10 KA, 'B' curve of rating 32 Amp all as specified and directed.
110S&F bldg secuirty light fitting energy saving high efficiency LED street light fitting 35 Watts, 5700 K, IP 66, having pressure die cast housing with toughened glass and individual high power LEDs with secondary optics, prismatic polycarbonate cover complete including GI bracket of size 25 mm dia bent to shape having length on less than 0.9 mtr fixing with clamp etc and making connections suitable size copper cable from ceilling rose/ PVC connector to light fittings or as directed by Engr-in-chrage.
111M&L for sub Main Wiring with 2 run of single core, 6Sqmm FRLS PVC insulated and unsheathed, multi starndedcopper conductor cable using colour code for phase red and neutral black with and including 6 Sqmm FRLS PVC insulated and unsheathed copper conductor cable in green colour as earth conductor connected to common earth dolly, drawn in and including concealed PVC rigid conduit of suitable size having thickness not less than 1.8mm (ISI marked) with and including all accessories complete and making good to disturbed surface of wall/floor with cement mortar and finishes to match existing surface including taking down of existing unserviceable surface/cocealed sub main wiring any type complete all as specified and directed. Note: Two run of submain wire (phase and neutral), and one run of earth including PVC conduit and accessories will be measured as one run.
112Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 16 sqmm 2core
113Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth and getting out in soft/loose soil for laying of cable ,pole foundation,stay,laying of pipe etc complete all as specified and directed.
114M&L for sand cushioning to under ground cables with a layer of sand 8 cm before laying the cable and 15 cm after laying the cable complete all as specified
115M&L for old size Brick covering with equal to length of brick as mechanical protection to cable with well burnt sub class 'B' bricks laid as directed.
116Returning filling in, including spreading ,leveling ,watering and well ramming in layers not exc 25 cm complete all as specified.
117Removing excavated soil to a distance not exceeding 50 mtr and deposting where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified.
118M & L for GI tubing light grade 50 mm bore for cable protection laid in trenches in road crossing or fixed to wall / pole (Rates incl accessories such as bend, clamps, nuts bolts and washers req for fitting)
119S&F GI pipe 20mm (3/4\\") dia, medium Grade complete including all fittings laid in trenches, floor, along with wall/ceiling etc complete all as specified and directed. (Rates incl accessories such as bend, clamps, nuts bolts and washers req for fitting)
120S&F gun metal, globe or gate valves, with iron wheel head screwed both ends for iron pipe and fixed 25mm dia all as specified.
121M & L for cutting/drilling of 50/80mm GI pipe for connection of 25mm GI pipe including all required accessories complete.
122Note:-The accepted amount will be arrived after deducting the Sch of credit i.e. Rs 6690.00.00 and any other reduction if any from quoted amount. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 58048651
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 30.94 Lakhs
LAST DATE 05-11-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Provn Of 02X Toilet Blocks 01 X Each In 734 & 736 Tpt Wksp Of 39 Eme Bn (Tpt) And special Repair To Roof Treatmennt To Govt Or Md Accn Bldg No Np-55, Np-56, Np-57 And Np-58 At Jagdish Vihar Of 14 Ew Bn Under Ge (West) Pathankot
Basic Detail
Tender No GE/PKT-70/2026-27
Bidding Type Tender
Location
City Pathankot
State Punjab
Key Dates
Publish Date 22 Oct 2026
Submission Date 05 Nov 2026
Open Date 01 Jan 0001
Finance
Tender Value 30.94 Lakhs
Tender Fee 500
EMD 61880
Exemption Not Available
Document List
70tender.pdf
abbe7a61-4955-4cb1-9589-491acbc1513a.html
BOQ_890486.xls
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Oct 22, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Nov 05, 2026
18:00 IST

Corrigendum-1 Issued

Clarifications on tender conditions and amendments issued.

Upcoming · 4 days
Nov 05, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 4 days

Tender Documents

Download All (ZIP) ↓
pdf

70tender.pdf

html

abbe7a61-4955-4cb1-9589-491acbc1513a.html

xls

BOQ_890486.xls

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender