Tender For Provn Of Poly House For Arboriculture And Special Repair To Internal Drain With Reinforced Cement Concrete Sump In Mes Ib Area At Pms Under Ge Panagarh
Tender Value
37.26 Lakhs
Estimated cost
Bid Submission
03 Nov 2026
15 days left
EMD
74600
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Purba Bardhaman → West Bengal
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Provn Of Poly House For Arboriculture And Special Repair To Internal Drain With Reinforced Cement Concrete Sump In Mes Ib Area At Pms Under Ge Panagarh
BOQ
| Sl. No. | Item Description |
| 1 | Surface excavation n.exc.30 cm deep and averaging 15 cm deep and getting out in soft/loose soil including clearing away all grass vegetation, saplings, shrubs, brush wood, under growth, roots and trees n. exc. 30cm girth and removing rubbish upto a distance of 50 metre out of the periphery of the area complete all as specified and as directed. |
| 2 | Excavating in trenches , n.exc 1.5 m wide and n.exc 1.5 m depth for foundation etc or for shafts, wells, cesspits ,manhole pier hole, laying of cables, pipes etc n.exc 10 sqm on plan and n.exc 1.5m in depth and getting out in any kind of soilNote : Manual excavation to be done. During excavation if any damage occured to existing cable any type/ water pipe line, it will be contractor responsibilty to get it repair and make functional by providing jointing kit etc without any extra cost. Contractor has to repair it within 24 hrs so that essential service can not be effected due to such damage.If contractor fails to repair it within 24 hrs penalty @ Rs 500/- will be charged to contractor. In this GE decision will be final, conclusive and binding. |
| 3 | Returning, filling, including spreading, leveling, watering and well ramming in layers not exc. 25cmin soft/loose soil complete all as specified and as directed. |
| 4 | Removal of excavated soil to a distance not exc 50 m and depositing where directed at a level not exc 1.5 mtr above the starting point complete all as specified and as directed. |
| 5 | Demolition of cement concrete (un reinforced) in ground floors and paving n.exc 15cm thickness (below or above ground (level) and lowering if necessary, removal of the rubbish off the premises complete all as specified and as directed. |
| 6 | Demolition of reinforced cement concrete in ground floors and pavings n.exc 15 cm thickness (below or above ground level) and removal of the rubbish off the premises complete all as specified and as directed. |
| 7 | Demolition of brick work built in CM including all quions, arches, pillars etc, but excluding ashlar facings, dressed stonework and precast concrete articles including removal of the rubbish off the premises complete all as specified and as directed. |
| 8 | M&L for pavings, with mix of fly ash, clinker & stone dust in the proportion of 1:3:6 (ie 10% fly ash, 30% clinker and 60% stone dust ) laying in layers n. exc 10cm thick, watering, ramming and compacted with hand/power roller 8 to 12 tonn roller to required camber and gradient complete all as directed by Engineer-in-Charge. |
| 9 | M & L for PCC (1:4:8) Type D2 using 40 mm graded aggregate used as in sub base for drain and finishing complete all as specified and as directed. |
| 10 | M&L Cement concrete 1:3:6, type C-2 (using 40mm graded stone aggregate) in foundations, filling and mass concrete complete all as specified and directed. |
| 11 | M&L Brick work with flyash old size bricks, straight or curved on plan exc. 6m mean radius built in cement mortar 1:6 complete all as specified and as directed. |
| 12 | M&L Brick work with flyash old size bricks, straight or curved on plan exc. 6m mean radius built in cement mortar 1:4 complete all as specified and as directed. |
| 13 | M&L for brickwork with bricks obtain from demolition, straight or curved on plan exc. 6 m mean radius, built in cement mortar (1:4) complete all as specified.(Bricks obtained from demolition shall be reused) |
| 14 | S&F Precast factory made SFRC (Steel Fibre Reinforced concrete) M-25 drain cover Minimum size 1.00 sqm each along with its SFRC frame, shape square or rectangular (Minimum weight 65 kg/Sqm) with min. 50mm thickness of slab cover each set at the top of the drain with 2 hooks to hold, with suitable reinforcement embedded complete all as specified and as directed by Engr-in-Charge. |
| 15 | M & L for RCC M-25 design mix concrete with using 20mm graded crushed stone aggregates as in foundations, including rafts, footings, foundation beams, plinth beams, bases for columns, etc.complete all as specified and as directed. |
| 16 | M & L for RCC M-25 design mix concrete with using 20mm graded crushed stone aggregates as in walls, retaining walls, basement walls, ballast walls and like any thickness, above top of footings, including attached pilasters and buttresses complete all as spd and directed. |
| 17 | M & L for RCC M-25 design mix concrete with using 20mm graded crushed stone aggregates as in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as spd and directed. |
| 18 | M & L for RCC M-25 design mix concrete with using 20mm graded crushed stone aggregates as in Columns, pillars, piers, posts and struts complete all as spd and directed. |
| 19 | M&L for Steel Centering and shuttering including strutting, propping etc. and removal of form to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter |
| 20 | M&L for Steel Centering and shuttering including strutting, propping etc. and removal of form for Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc. |
| 21 | M&L for Steel Centering and shuttering including strutting, propping etc. and removal of form to sides of pillars, posts, struts, piers, columns and stanchions for fair finished surface of concrete Complete all as specified and directed. |
| 22 | M&L for Steel Centering and shuttering including strutting, propping etc. and removal of form to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping), for fair finished surface of concrete, all as specified and as directed. |
| 23 | M&L for forming 100 cm inner girth fair finished drains or channels in cement concrete using extra cement including forms, moulds, mitred/stopped ends etc complete all as specified and directed. |
| 24 | S&F mild steel TMT bar 10 mm dia and over, as in reinforcement, cut to length, bent to shape etc, including binding with and including mild steel wire (annealed) not less than 0.9 mm dia complete all as specified and directed. |
| 25 | S&F mild steel TMT bar 5 mm dia and over upto and including 10mm dia in stirrups, spacers and binders , cut to length, bent to shape etc, including binding with and including mild steel wire (annealed) not less than 0.9 mm dia complete all as specified and directed. |
| 26 | M&L for Providing precast cement concrete type B-0, 1:2:4 (12.5mm grades aggregate) in window or door cills, lintels, bressumers, steps, quoin blocks (for use with masonry), string courses, copings. kneelers, apex stones, pier caps, columns, posts, boundary pillars, bed plates, pintle blocks, ancho-rage blocks, bonders (for stone walling). corbels, brackets, etc including frames (of any section indicated), with plain fair faces, including chamfers, weatherings, throat- ing etc. and setting in mortar 1:4 complete with joints to match complete all as spd and directed. |
| 27 | M&L for cement concrete type B-0, 1:2:4 (using 12.5mm graded stone aggregate) in surface channels and drains for benching complete all as spd and directed. |
| 28 | Rendering 15mm thick in cement mortar 1 :4 on fair faces of brickwork or concrete surfaces and finished the surfaces even and smooth complete all as specified and directed. |
| 29 | Supplying and laying of PVC underground drainage sewer system pipe bearing 160 mm dia SN 4 including jointing with couplar, bend tee as per site requirement complete laid in trenches or floors complete all as specified and directed. |
| 30 | Material and labour for cement concrete bed to drain pipe for 150mm bore of pipe including forming cradles in Cement concrete 1:3:6 Type C2 complete all as specifiedand and as directed. |
| 31 | S&F in repair for 300mm bore reinforced concrete pipes, class NP3 , laid and jointed complete all as spd and directed. |
| 32 | Material and labour for cement concrete bed to drain pipe for 300mm bore of pipe including forming cradles in Cement concrete 1:3:6 Type C2 complete all as specifiedand and as directed. |
| 33 | S&F for Framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete all as spd and directed. |
| 34 | Opening of existing RCC culvert in any depth and any size through boring or other method to clearing blockage etc , by manuallly rodding as required at site, flushing the line and culvert with water as to make the line fully functional to the entire satisfaction of Engr-in-Charge and removing of sludge/soil upto 500 mtr complete all as spd and directed. Please Enable Macros to View BoQ information |
| 35 | Opening of existing RCC culvert in any depth and any size through boring or other method to clearing blockage etc , by manuallly rodding as required at site, flushing the line and culvert with water as to make the line fully functional to the entire satisfaction of Engr-in-Charge and removing of sludge/soil upto 500 mtr complete all as spd and directed. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Oct 15, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedNov 03, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 15 daysNov 04, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 16 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender