Defence Statutory Bodies & Commissions/Committees Closing in 17 days TDR #58048609

Tender For Special Repair To Earthing And Other Misc Items Of E/M Installtion For Camero Units At Subroto Park

Issued by Statutory Bodies & Commissions/Committees · New Delhi, Delhi
Tender Value
47.55 Lakhs
Estimated cost
Bid Submission
04 Nov 2026
17 days left
EMD
95100
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
New Delhi → Delhi
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Special Repair To Earthing And Other Misc Items Of E/M Installtion For Camero Units At Subroto Park

BOQ

Name of Work:- SPECIAL REPAIR TO EARTHING AND OTHER MISC ITEMS OF E/M INSTALLTION FOR CAMERO UNITS AT SUBROTO PARK
Sl. No. Item Description
1M&L for Conductive Concrete Earth Grid of multiple interconnected Earth Electrodes to achieve the earth resistance value of less than < 5 Ω. The excavation is to be carried out in any type of soil including hard rock. The approx specification are as under:-(i) Earth Electrodes: Metal conductor - Copper bonded MS rod dia 17.2 mm (+/-.5mm), Length 2.25 meter with conductive concrete including provision of bore 80 mm dia, 2.25 meter Length of earth electrode.
2(ii) All earth electrodes (min two nos) should be installed to achieved the desired result . (iii) Interconnected Strip: All the multiple Earth Electrodes will be horizontally interconnected with metal conductor - Copper strip flat size : 25mm x 3 mm & conductive concrete embedding size : 60 mm².(iv) Test Link : Test links - Copper strip flat size : 40 mm x 6 mm x 200 mm shall be provided, at any one of the multiple Earth Electrodes of the grid for connection between earth grid pit and application.(v) Pit Cover : RCC pit cover & frame shall be provided at all Earth Electrode (with test links).
3Note :- (a) Bidder shall produce certificate for resistivity of conductive concrete.(b) Fault Current Tested at 40 KA Peak With 17.2mm copper bonded rod .(c ) On completion of work Engineer in charge will check the earth resistance , Contractor will re-do the earth if earth resistance value is more than 5 Ohm if value not found as per contract the necessary action to be taken by the contactor for achieving the desire result. (d) All connecting strips would be of copper of size 25x3 mm and cost of the same is included in the rate quoted, upto test point.(e) Test certificate of earthing material for ROHS compliance, Resistivity value and fault current test for electrode from certified NABL laboratory shall be submitted. (f) The vendor to provide CPRI test report for current greater than 20 KA with peak at 40 KA, The report shall not be more then 5 year old from the date of tender. (g) The product should be ROHS compliance. (h) The earthing to be carried out by OEM only. The MOU in this respect to be submitted by contractor before execution of the work.
4Design, supply, install, testing and commissioning of factory made LT Panel Outdoor type, cubical enclosure compartmentalized external and internal mirror type brushed finish suitable for highly corrosive environment, high creep resistance, better mechanical properties like ductility, yield strength, hardness etc.The enclosure shall be made of 2.00 mm thick stainless steel sheet SS 316 sheet. The fixing of double doors shall be on SS hinges with anti-theft provision. All fabrication/welding shall be done with TIG/MIG or as approved by Engineer in charge suitable for SS 316. Sliding handle and locking arrangement front and rear both side. Enclosure shall be suitable for AC supply system 415 volts, 3 phase, 4 wire, 50 Hz. Degree of protection shall be IP-54. The enclosure shall have provision of cable entry. Cable entry from bottom side in seperate cable alley on both side, seperated with bakelite sheet of suitable size, including internal wiring with PVC insulated solid, copper wire, 1100 volts grade. The panel shall consist of TPN aluminium bus bars of size 1.5 time of main incomming rating switch gear and shall be provided with colour coded heat shrinkable sleeves. The panel shall be provided with separate compartments for each switch grar, including instrumentation such as Ampere meter, Volt meter, phase indicating lamps etc with double stud hinged door, front & rear openable with locking arrangement including interlocking with switch gears. The panel shall be fixed with angle iron frame made of angles of size 50 X 50 X 6mm, embedded 200 mm below ground level in PCC 1:2:4, Type B-1 using 20mm grade stone aggregate, 600 mm above ground level and comprising the following:
5Incomimg:- (a) MCCB TPN 630 Amp, 4 pole rupturing capacity 36 KA at 415 volt Ics = 100% Icu - 01 Nos with RHOM Makes :- ABB/Seimens/Schenider/Legrand (b) Digital Multifunction Meter to measure KWh, PF, VLL, VLN, W, VA ,V, I including CT and PT complete with all electrical connection - 01 No (c) LED type Phase indicator lamps (R, Y, B) - 1 Set Outgoings:- (a) MCCB TP 125 Amp, 3 pole rupturing capacity 25 KA at 415 volt Ics = 100% Icu - 04 Nos With RHOM Makes :- ABB/Seimens/Schenider/Legrand (b) MCCB TP 80 Amp, 3 pole rupturing capacity 16 KA at 415 volt Ics = 100% Icu - 08 Nos With RHOM Makes :- ABB/Seimens/Schenider/Legrand (c) Control MCB 6 Amps SP-03 Nos
6Design, supply, install, testing and commissioning of factory made LT Panel Outdoor type, cubical enclosure compartmentalized external and internal mirror type brushed finish suitable for highly corrosive environment, high creep resistance, better mechanical properties like ductility, yield strength, hardness etc.The enclosure shall be made of 2.00 mm thick stainless steel sheet SS 316 sheet. The fixing of double doors shall be on SS hinges with anti-theft provision. All fabrication/welding shall be done with TIG/MIG or as approved by Engineer in charge suitable for SS 316. Sliding handle and locking arrangement front and rear both side. Enclosure shall be suitable for AC supply system 415 volts, 3 phase, 4 wire, 50 Hz. Degree of protection shall be IP-54. The enclosure shall have provision of cable entry. Cable entry from bottom side in seperate cable alley on both side, seperated with bakelite sheet of suitable size, including internal wiring with PVC insulated solid, copper wire, 1100 volts grade. The panel shall consist of TPN aluminium bus bars of size 1.5 time of main incomming rating switch gear and shall be provided with colour coded heat shrinkable sleeves. The panel shall be provided with separate compartments for each switch grar, including instrumentation such as Ampere meter, Volt meter, phase indicating lamps etc with double stud hinged door, front & rear openable with locking arrangement including interlocking with switch gears. The panel shall be fixed with angle iron frame made of angles of size 50 X 50 X 6mm, embedded 200 mm below ground level in PCC 1:2:4, Type B-1 using 20mm grade stone aggregate, 600 mm above ground level and comprising the following:
7Incomimg:- (a) ACB 1250 Amps 4 Pole, 50 kA, 50Hz at 440 Volts with Microprocessor based release Manual drawout type ( MDO ) with overload, Short circuit, instanteneous Protection including neccessary bus bar for connection incoming cable s complete- 1 set Makes :- ABB/Seimens/Schenider/Legrand (b) Digital Multifunction Meter to measure KWh, PF, VLL, VLN, W, VA ,V, I including CT and PT complete with all electrical connection - 01 No (c) LED type Phase indicator lamps (R, Y, B) - 1 Set Outgoings:- (a) MCCB 200 Amp, 3 pole rupturing capacity 25 KA at 415 volt Ics = 100% Icu - 06 Nos With RHOMMakes :- ABB/Seimens/Schenider/Legrand (b) MCCB 125 Amp, 3 pole rupturing capacity 25 KA at 415 volt Ics = 100% Icu - 06 Nos With RHOMMakes :- ABB/Seimens/Schenider/Legrand (c) Control MCB 6 Amps SP-03 Nos
8Design, supply, install, testing and commissioning factory made LT Panel Outdoor type, cubical enclosure compartmentalized external and internal mirror type brushed suitable for highly corrosive environment, high creep resistance, better mechanical properties like ductility, yield strength, hardness etc.The enclosure shall be made of 2.00 mm thick stainless steel sheet SS 316 sheet. The fixing of Front doors shall be on SS hinges with anti-theft provision. All fabrication/welding shall be done with TIG/MIG or as approved by Engineer in charge suitable for SS 316. Sliding handle and locking arrangement front and rear both side. Enclosure shall be suitable for AC supply system 415 volts, 3 phase, 4 wire, 50 Hz. Degree of protection shall be IP-54. The enclosure shall have provision of cable entry. Cable entry from bottom side including internal wiring with PVC insulated solid, copper wire, 1100 volts grade.The panel shall consist of TPN aluminium bus bars of capacity 1.5 times of Incommer MCCB/ACB and shall be provided with colour coded heat shrinkable sleeves. (For LT Panel ( Lift & Fire fightening & Comman Area) at Sub Stn 'D')
9Incomimg:- (a) MCCB 630 Amp, 4 pole rupturing capacity 36 KA at 415 volt Ics = 100% Icu - 01 Nos with RHOMMakes :- ABB/Seimens/Schenider/Legrand (b) Digital Multifunction Meter to measure KWh, PF, VLL, VLN, W, VA ,V, I including CT and PT complete with all electrical connection - 01 No (c) LED type Phase indicator lamps (R, Y, B) - 1 Set Outgoings:- (a) MCCB TP 125 Amp, 3 pole rupturing capacity 25 KA at 415 volt Ics = 100% Icu - 03 Nos With RHOM Makes :- ABB/Seimens/Schenider/Legrand (b) MCCB TP 80 Amp, 3 pole rupturing capacity 16 KA at 415 volt Ics = 100% Icu - 7 Nos With RHOM Makes :- ABB/Seimens/Schenider/Legrand (c) Control MCB 6 Amps SP-03 Nos
10Note for BOQ item No 2 to 4: (i) Rates are inclusive for fixing of suitable size cable gland if required in existing or new cable, CT/ PT and elctrcal connection complete to function multi functional meter. (ii) Danger notice plate must be fixed on panel . (iii) The manufacturer should have Govt. approved certificates:- (a) Panel should be according to IEC-61439, CPRI certificate Degree of protection IP-54. (b) IS/ IEC : 61439 (Part-I & Part-II) 2011 and all necessary certification as per relevant IS/IEC codes
11Taking out old/defective cable XLPE/PVC sheathed 1100 volt grade heavy duty armoured with aluminium conductor cable of size 400-300 sqmm 3.5 core from trenches/wall under ceiling etc complete all as specified and directed.
12Taking out old/defective cable XLPE/PVC sheathed 1100 volt grade heavy duty armoured with aluminium conductor cable of size 240-185 sqmm 3.5 core from trenches/wall under ceiling etc complete all as specified and directed.
13All as per item No-6 above but cable size 95 sqmm 3.5 core
14Supply, laying, jointing and testing of LT cable XLPE Insulated ,screened, PVC bedded, galvanized steel strips armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminum conductor of size 400 sq mm 3½ core complete all as specified and directed with necessary cable glands at end, aluminium lugs for connecter complete all as specified and directed.
15Supply, laying, jointing and testing of LT cable XLPE Insulated ,screened, PVC bedded, galvanized steel strips armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminum conductor of size 240 sq mm 3½ core complete all as specified and directed with necessary cable glands at end, aluminium lugs for connecter complete all as specified and directed.
16Supply, laying, jointing and testing of LT cable XLPE Insulated ,screened, PVC bedded, galvanized steel strips armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminum conductor of size 185 sq mm 3½ core complete all as specified and directed with necessary cable glands at end, aluminium lugs for connecter complete all as specified and directed.
17Supply, laying, jointing and testing of LT cable XLPE Insulated ,screened, PVC bedded, galvanized steel strips armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminum conductor of size 95 sq mm 3½ core complete all as specified and directed with necessary cable glands at end, aluminium lugs fir connecter complete all as specified and directed.
18M&L for cutting of Hardstanding/ road by mannual method upto 200mm deep for inserting GI pipe for cable protection complete including ready mix concreate and making good distrubed surface all as specified and as directed.
19Excavating in trenches in any type of soil/rocks not exceeding 1.5 m wide and not exceeding 1.5 m in depth for foundation, laying of cable etc not exc 10 Sq mtr on plan and not exc 1.5 mtr in depth and getting out complete all as specified.
20Returning , filling in , including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick in hard/dense soil complete all as specified and as directed.
21Removing excavated surplus soil to a distance upto 50m and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified and as directed.
22Material and labour for sand cushioning by using fine sand ( Jamuna dry and clean sand ) in two layers , first layer of 80mm thick before laying of cable and second layer of 150mm thick after laying of cable complete all as specified and as directed.
23Supply and lay unreinforced Precast cement concerete cable cover for protection of under ground cable in trenches class LV size 250X150X40 mm
24Supply and laying GI tube light grade as in cable protection pipe including all fittings complete for the size 150mm dia bore complete all as specified and directed.
25Supply and laying GI tube light grade as in cable protection pipe including all fittings complete for the size 80mm dia bore complete all as specified and directed. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 58048609
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 47.55 Lakhs
LAST DATE 04-11-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Special Repair To Earthing And Other Misc Items Of E/M Installtion For Camero Units At Subroto Park
Basic Detail
Tender No GE/SP/TOKEN-70/2026-27
Bidding Type Tender
Location
City New Delhi
State Delhi
Key Dates
Publish Date 14 Oct 2026
Submission Date 04 Nov 2026
Open Date 07 Nov 2026
Finance
Tender Value 47.55 Lakhs
Tender Fee 500
EMD 95100
Exemption Available
Document List
94bb26a8-5409-411d-8a47-076e39d468a4.html
BOQ_890233.xls
TENDER70.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Oct 14, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Nov 04, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 17 days
Nov 07, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 20 days

Tender Documents

Download All (ZIP) ↓
html

94bb26a8-5409-411d-8a47-076e39d468a4.html

xls

BOQ_890233.xls

pdf

TENDER70.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender