Project Description

Tender for Addition / Alteration To Building No P-73 (Navik Institute) At Coast Guard Under Ge Haddo, Sri Vijaya Puram

BOQ

Name of Work:- ADDITION / ALTERATION TO BUILDING NO P-73 (NAVIK INSTITUTE) AT COAST GUARD UNDER GE HADDO, SRI VIJAYA PURAM
Sl. No. Item Description
1Taking down chowkhat with shutters (without taking off shutters from the frame) area n exc 1.5 Sqm each all as specified and directed.
2Taking down chowkhat with shutters (without taking off shutters from the frame) area exc 1.5 Sqm and n exc 4 Sqm each all as specified and directed.
3Demolition of (unreinforced) cement concerete in ground floors and paving not exceeding 15 cm thickness (below or above GL) etc, complete all as specified and as directed.
4M&L for providing PCC 1:3:6 type C2 (using 40mm graded stone agg) as in plinth protection 75 mm thick finished over and smooth without using extra cement etc all as specified and directed.
5M&L PCC (1:4:8) type D2 using 40mm graded stone aggregate as in 75mm thick as in sub base complete all as specified & directed by Engineer-in-Charge.
6M&L for 25 mm thick plain cement concrete 1:2:4 type B0 using 12.5 mm graded stone aggregate as in sub base for floors all as specified and directed.
7M&L for plain cement concrete 1:4:8 type D2, using 40mm graded stone aggregate in foundation, filling, mass concrete, levelling courses and sub bases etc, including demolition of cement concrete (un-reinforced) in ground floors and paving not exceeding 15cm thick above or below ground level all as specified and directed.
8M&L PCC 1:2:4 type B2 (40mm grade stone agg) as in cement concrete in surface channel and drain, including demolition of cement concrete (un-reinforced) in ground floors and paving not exceeding 15cm thick above or below ground level all as specified and directed.
9Material and labour for providing Plain Cement Concrete (1:2:4) type B1 using 20 mm graded aggregate as in lintels upto 1.5 m clear span, cills, steps, seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, coping, kneelers, apex stones etc water troughs and the like including weathering, slightly rounded or chamfered angles and throating, including necessary form work, including demolition of cement concrete (un-reinforced) in ground floors and paving not exceeding 15cm thick above or below ground level all as specified and directed.
10M&L for pre-cast cement concrete solid block masonry, exc 10cm width, blocks cast in PCC 1:3:6 type C1, using 20mm graded stone aggregate, set in CM 1:6, including demolition of brickwork or stone / boulder masonry, built in lime mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles etc, complete all as specified and directed.
11Supply and fix for factory made single extruded WPC (Wood Polymer Composite) solid door/ window/Ceosetory windows & other Frames/Chowkhat of size 45x70 mm comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum comp ressive strength of 58 N/mm2 , modules of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite /borer proof, water/ moisture proof and fire retardant and fixed in position with MS hold fast/ lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-in-Charge. (M.S. hold fast/ lugs or SS dash fasteners shall be paid for separately).Note: For WPC solid door/window frames, minus 5mm tolerance in dimension i.e. depth and width of profile shall be acceptable. Variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be made.
12Supply and fix for factory made single extruded WPC (Wood Polymer Composite) solid plain flush door shutter of 30 mm size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2 , modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer-In-Charge.
13S&F for Powder coated aluminium (minimum thickness of powder coating 50 micron) work for doors, windows, ventilators, partitions and shutters with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285 fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ paneling, C.P. brass/ stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-Charge.
14S&F for Powder coated Aluminium grill (minimum thickness of powder coating 50 micron) of approved design/pattern, with approved standard section and fixed to the existing window frame with C.P. brass/ stainless steel screws @ 200 mm centre to centre, including cutting the grill to proper opening size for fixing and operation of handles and fixing approved anodised aluminium standard section around the opening, all complete as per requirement and direction of Engineer in charge.
15Dismantling structural steel work of any description complete all as specified.
16M&L for rolled section as in main and cross beam, hip and jack rafter,purlins where connected to common rafters and running rails and guides for sliding doors fixed with angle cleats or other connecting plates of grade Fe-410 (grde E-250)quality-A, etc complete all as specified and as directed
17M&L for aluminium wind tie of any size fixed with self tapping screws of size 50/75mm with integral EPDM washer in roof covering and including dismantling of old wind tie etc fixed with self tapping screws as specified.
18Material and labour mild steel Plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, with riveted, bolted or welded attachment conforming to Fe 290 grade E-165 etc, complete all as specified and as directed.
19Dismantling of Plain or corrugated steel sheeting, any gauge, thickness, including or similar pattern roof coverings etc, complete all as specified and as directed.
20S&F Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete as specified and as directed.
21S&F Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete as specified and directed.
22M&L in repairs to Aluminium composite panel sheet of 3.0mm thick with skin thickness of 0.25mm of aluminium on both sides, sandwiched by 2.5mm polyethylene core with PVDF coating of 30.0micron fixed over frame of aluminium tabular section 50x25mmx 2.0mm thick, having panels not exc 1200x1200mm with necessary silicon filling, in approved pattern as in column, beam, wall at any height with necessary scafoldings etc complete as specified and as directed.
23M&L in repairs to Aluminium composite panel sheet of 3.0mm thick with skin thickness of 0.25mm of aluminium on both sides, sandwiched by 2.5mm polyethylene core with PVDF coating of 30.0micron fixed with necessary silicon filling, in approved pattern as in column, beam, wall at any height with necessary scafoldings etc complete as specified and as directed.
24S&F for 0.71 mm thickness Plain, Aluminium sheeting, Alloy 31000 H4 in ridges, hips, valley gutter, drip and straight flashing (length and girth as fixed) with necessary fittings etc, complete all as specified and directed.
25S&F PVC insulation panels (thickness of insulation pannel 10mm) with EPS stuck to 1mm plain PVC sheet suitable placed in false ceiling grid made of Anodised aluminium snap grid frame work for false ceiling and including 6mm thick GI hangers adjusting level fixed to roof slabs by means of ceiling cleats made out of GI flats 40x3 mm size long and expansion hold fasteners 12.5mm dia 40mm, long including dismantling of ceiling boards including grid of any description fixed in any position with nails or screws etc all as specified and as directed.
26M&L in repairs to 12 mm thick WPC (Wood-Plastic Composite) louvers Panel boards as in Wall panelling work fixed over frame work using suitable aluminium profile sections of size 50mmx25mmx2mm thick and fixed with suitable screws / fasteners as per the site requirents etc complete all as specified and directed.Note: Design and Pattern shall be as approved
27Supply & Installation of WPC False Ceiling exterior/interior grade Wood Plastic Composite (WPC) false ceiling panels (5 mm / light weight standard interlocking profile) of approved shade and timber texture. Item includes aluminum heavy-duty perimeter channels, main runners, intermediate sections suspended with adjustable hangers, clips, metal fasteners, and jointing accessories complete as per drawing and direction of Engineer-in-Charge
28M&L for Preparation of Painted internal wall / ceiling surface and fixing 3 mm thick UV Marble sheet design (waterproof & scratch proof with self adhesive type or pasting with suitable adhesive to the wall surface etc complete all as specified and as directed.Note: Design / Colour will be finilised.
29M&L for 3 mm thick Polygranite sheet boards/panels for wall/ceiling panelling, of approved make, colour, texture and finish, fixed over aluminium framework comprising 50 × 25 × 2 mm thick aluminium profile sections, securely anchored/fixed to existing substrate/supports with suitable corrosion-resistant screws/fasteners, including cutting, drilling, necessary supports, alignment, jointing clips/profiles, edge trims and finishing accessories, complete as specified and as directed by Engineer-in-Charge.Note: Design, pattern, colour, texture and arrangement of panels shall be finalized by the Engineer-in-Charge before execution
30M&L for 3 mm thick Polygranite sheet boards/panels for wall/ceiling panelling, waterproof and scratch resistant, of approved make, colour, texture and finish, fixed by direct pasting to prepared wall/ceiling surface using suitable heavy-duty waterproof nail-free adhesive, including surface preparation, cutting, trimming, jointing clips/profiles, edge finishing and all necessary accessories to obtain a neat, level and uniform finish, complete all as specified, as per manufacturer's recommendations and as directed by Engineer-in-Charge.
31Material & Labour for stainless steel (Grade 304) railing made of hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (where ever required) and fitting the same with necessary stainless steel nuts and bolts complete, including fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of floor or the side of waist slab with suitable arrangement etc, complete all as specified and as directed.
32S& F in repairs, 25 mm dia Stainless steel curtain rods with fancy type curtain brackets, stops, rollers as per the site requirements etc complete all as specified and as directed.
33M& L for Vitrified Ceramic tiles drak shade 10 mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or colored cement to match including screed bed or bedding layers 15 mm thick in cement mortar (1:6) for laying floor finishes including dismantling floor hearth or wall tiling including cement mortar bedding (but not backing) removing, rubbish off the premises all as specified and directed.complete all as specified and directed.
34S&F Non Skid ceramic tiles 7 to 8mm thick (square/rectangular) area of each tile exceeding 0.11 but not exceeding 0.18 sqm, as in floors etc. set and jointed in neat cement slurry and pointed in white or colored cement to match including screed bed or bedding layers 15 mm thick in cement mortar (1:6) for laying floor finishes including dismantling floor hearth or wall tiling including cement mortar bedding (but not backing) removing, rubbish off the premises all as specified and directed. complete all as specified and directed.
35S&F glazed ceramic tiles (350x450 x 7mm thick ) on dado & skirting , set and jointed in neat cement slurry and pointed in white or colored cement to match including 10 mm thick rendering with rough finished in cement mortar 1:4 to received tile including dismantling floor hearth or wall tiling including cement mortar bedding (but not backing) removing, rubbish off the premises all as specified and directed. etc, complete all as specified and directed.
36M&L for Granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window-cills, cooking platforms,floor, walls and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite and polishing including dismantling of existing unserviceable stone tiles alongwith cement mortar bedding (but not backing) and removing rubbish off the premises complete all as specified and directed.
37Providing edge moulding to 18-20mm thick stone of counters vanities etc. including machine polishing to edge to give high gloss finish etc. complete all as specified and directed.
38S&F in repairs 15 mm bore pillar taps, cast copper alloy, chromium plated fancy type screwed down high pressure with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly nuts screwed for iron pipe and fixed etc complete all as specified and directed.
39S&F in repairs for CP Bib taps 15mm dia long body with flange cast copper alloy fancy type with crutch or capstan head handle screwed down for Iron pipe and fixed etc complete all as specified and directed.
40S&F in repairs CP two way bib taps 15mm cast copper alloy fancy type with crutch or capstan head handle screwed down for Iron pipe and fixed etc complete all as specified and directed. (Make : Prayag Cart Part No 5212 or Equivalent approved)
41S&F Brass health faucet 1.0 mtr long flexible tube with wall hook etc complete all as specified and as directed. (Make Prayag Cat Part No. BEA-106 or Equivalent approved)
42S&F in repairs CP Angular stop cock fancy type with crutch or capstan head handle screwed down for Iron pipe and fixed etc complete all as specified and directed. (Make :Prayag Cat No. 7210 or Equivalent approved)
43S&F in repairs Vitreous China wash basin, white, flat back, size 550x400mm, but including bracket (flat back or angle back type) any size, including cutting for and pinning in ends of brackets or erecting stand but exclusive of fixing of supply and waste pipe and fittings, brass, chromium plated for glazed ware sinks, basins, etc. with long screwed shanks and fly-nuts, flange end bedded in red lead cement and other end fixed etc complete all as specified and as directed.
44Cutting chases in PCC block walls for concealed water tubing etc., and making good, cutting not exc 10 cm girth complete all as specified and as directed.
45S& F for 20mm bore Supplying and laying of CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings in trenches complete all as specified. complete to walls, ceiling or in floor, including taking up or down 20mm dia steel tubing connection, including cleaning for refixing or removal to store etc complete all as specified and as directed.
46Supplying and fixing of outer diameter 20 mm CPVC Brass Elbow fittings on walls/ceiling or laying in floors complete all as specified.
47Supplying and fixing of outer diameter 20 mm CPVC Brass Tee fittings on walls/ceiling or laying in floors complete all as specified.
48S& F for 25mm bore Supplying and laying of CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings in trenches complete all as specified. complete to walls, including taking up or down 25mm dia steel tubing connection, including cleaning for refixing or removal to store etc complete all as specified and as directed.
49Supplying and fixing of outer diameter 25 mm CPVC Brass Elbow fittings on walls/ceiling or laying in floors complete all as specified.
50Supplying and fixing of outer diameter 25 mm CPVC Male Brass Threaded Adaptor (MTA/ MBTA) fittings on walls/ceiling or laying in floors complete all as specified.
51Supplying and fixing of outer diameter 25 mm CPVC Female Brass Threaded Adaptor (FTA/ FBTA) fittings on walls/ceiling or laying in floors complete all as specified.
52Supplying and fixing of outer diameter 25 mm CPVC UNION fittings on walls/ceiling or laying in floors complete all as specified.
53Supplying and fixing of outer diameter 25 mm CPVC Ball Valve fittings on walls/ceiling or laying in floors complete all as specified.
54Taking down eaves gutters and rainwater pipes (any size or pattern), including all fittings, heads, shoes, bends, swan-necks, etc., including cleaning or refixing or removal to Store (measured overall as fixed along the centre line over fitting and accessories) etc complete all as specified and as directed.
55S&F for 110mm dia PVC (SWR) grade single socketed pipes in any length complete with rubber ring joints fixed to wall etc using synthetic rubber adhesive cement solvent etc complete all as specified and as directed.
56S&F for 75mm dia PVC (SWR) grade single socketed pipes in any length complete with rubber ring joints fixed to wall etc using synthetic rubber adhesive cement solvent etc complete all as specified and as directed.
57S&F for 110mm dia PVC (SWR) bends any radius etc complete all as specified and as directed.
58S&F for 110mm dia PVC (SWR) bends with acess door any radius etc complete all as specified and as directed.
59S&F for 75 mm dia PVC (SWR) grade bends of any radius etc complete all as specified and as directed.
60S&F for 75 mm dia PVC (SWR) grade bends with acess door of any radius etc complete all as specified and as directed.
61S&F PVC (SWR) vent cowl, 75mm dia etc complete all as specified and as directed.
62Supply and fix in repairs Vitreous China Urinal, full stall type, white including providig bottle trap and fixing plugs ,bedding urinal against wall in cement mortar 1:2 ,securing urinal to plugs with and including 60 mm long brass screws ,pointing around urinal back in cement complete all as specified and as directed.
63Disconnecting existing tanks of capacity 500 litre to 1000 litre from water supply conections, setting aside (or lowering if required) for repairs, cleaning, etc. and rehoisting if required reconnecting and re-fixing in position etc, complete all as specified and directed.
64M & L plain cement concrete with type B1 1:2:4 ( using 20 mm graded stone aggregate) avg thickness 40mm in roof padding concrete, kerbs or mud stops or rounded or chamfered on edge mixed with WPC as per manufacture's instruction complete all as specifed and directed.
65M & L for 10 mm thick screed bed in CM 1:3 in roof surfaces mixed with WPC as per manufacture's instruction complete all as specified and as directed.
66S&F for Applying evenly a tack coat of industrial bitumen 85/25 at the rate of 1.2 kg per sq.m including cleaning surfaces complete all as specified and as directed .
67M&L for laying APP modified water proofing treatment over existing RCC roof slab with following specification including brushing off the surface to receive the treatment obtain the required surface :- (a) Applying bituminous primer @ 1.2 kg/Sqm on the prepared dry roof surface.(b) Laying min 3mm thick APP membrane Plain finish weight not less than 3 to 4 kg per sqm by torch application with minimum 10cm side lap and 15cm end lap.(c) Applying two coat of aluminium paint incl preparartion of surface.Note :Laying of APP membrane shall be got done through an authorized applicator of manufacturer.
68Preparation of any surface as directed over the roof and applying two coats of aluminium paints complete all as specified and as directed by Engineer-in-Charge.
69M&L for complete removal of existing treatment on wall by scrapping, washing, cleaning etc and applying filling the crack seal of walls with crack seal (on crack portion), and applying two coat of exterior damp proof painting one coat of primer from same manufacturer including necessary scaffolding up to 12 m complete all as specified and directed .Note:- Painting work applied by authorized applicators as per manufacturer instructions. Make: FOSROC (damp proof) or equivalent
70M&L for rendering 15mm thick in cement mortar 1: 4 mixed with water proofing compound on fair faces of brick work or concrete surfaces finished even and smooth without using extra cement, including taking down cement plaster on brick or concrete surfaces wall etc. including racking out joints hacking for key scrubbing down with water etc complete all as directed.Note: Water proofing compound shall be measured and paid separately.
71Supply only integral water proofing compound all as specified and as directed.
72M&L rendering 10mm thick in CM 1:6 on brick surfaces and finished even and smooth w/o using extra cement etc, including taking down cement plaster on brick or stone wall or ceiling concrete etc. including racking out joints hacking for key scrubbing down with water etc completed all as specified and directed.
73M&L for rendering 5mm thick in cement mortar 1:3 on fair faces of ceiling concrete surfaces finished even and smooth without using extra cement complete all as directed.
74M&L for rendering 15mm thick in cement mortar 1:4 on fair faces of brick work or PCC block masonry or concrete surfaces finished even and smooth without using extra cement complete all as directed.
75Material & Labour for applying two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces etc, all as specified and directed
76M&L for new plastered on walls and applying two coats of oil bound distemper over a preparatory coat of 1mm thick plaster of paris putty on plastered surface over a coat of priming plastered and other surfaces with alkali resistant priming paint, including necessary preparation of surfaces etc, completed all as specified and directed.
77M&L preparation of new plastered ceilling surfaces and applying two coat of distemper oil emulsion over a coat primer etc, complete all as specified and directed.
78M&L for complete removal of existing treatment on wall by scrapping, washing, cleaning etc with 1mm thick plaster of paris putty and applying two coats of acrylic emulsion distemper over one coat primer including filling of cracks, holes and including leveling the surface which undulation found with wall care putty etc. all as specified.
79Material and labour for Preparation of old decorated surfaces of ceiling by brooming down or steel wire brushing, scrapping down smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spots ,filling holes ,cracks with cement base putty and applying two coat of oil emulsion distemper (white/Tinted) complete all as specified and as directed.
80M&L preparing old wooden surfaces of any description over 10 cm width or girth and applying one coat of synthetic enamel paint complete all as specified
81M&L for preparation of old steel surfaces over 10 cm in width or girth not otherwise described and applying one coats of synthetic enamel complete all as specified and as directed.
82M&L for preparation old plastered surface of wall and applying one coats of weather proof (exterior grade) acrylic emulsion paint with anti fungal property over existing painted surfaces etc complete all as specified and as directed. (Make: Dulux Weather Shield Max or Apex Ultima from Asian Paints or Berger weather coat All guard or equivalent).Note: Rate quoted shall be deemed to include scafolding upto 12m height or as per the actual site requirements.
83M&L for preparation & cleaning of floor or chequered tile surfaces and applying one coat of terracotta paint etc complete all as specified.
84M&L for preparation of new steel surfaces of any description exc 10 cm width or girth when unconnected with other Painting or when painted in a different tint and applying two coats of synthetic enamel paint over a coat of red oxide primer etc, complete all as specified and as directed.
85Taking down carefully old unserviceable aluminum/ copper point wiring (light, fan, socket or power) complete, including fittings & fixtures such as switches, ceiling roses, lamp holders, pendants, regulators sockets, junction/terminal boxes etc; removing from site and making good disturbed surfaces of walls, floors etc., to match with existing surrounding surfaces complete all as specified and as directed.
86Taking down existing unserviceable main switches/ distribution boards/Fuse Units of any description alongwith MCBs/MCCBs and making good disturbed surfaces to match with existing surrounding finishes complete all as specified and as directed.
87Taking down existing unserviceable sub main wiring of any description and making good disturbed surfaces to match with existing surrounding finishes complete all as specified and as directed.
88M & L point wiring complete with 1100 volts grade, 1.5 sq.mm (nominal area), single core, FRLSH PVC insulated ,unsheathed, multi stranded copper conductor cable drawn through and including medium grade, rigid , non-metallic PVC concealed/ on surface conduit of size not less than 20 mm dia, with all necessary fittings, concealed in walls/ floor or surface on wall/ roof duly earthed with one run of single core cable of same size but green in colour as continuous earthing wire and connecting to common earth duly including suitable size of factory made fabricated MS sheet modular terminal box, flush mounting in the wall for mounting switches/switch socket combinations/ fan regulators etc., covered with suitable size of modular cover plates complete in making good the existing surface with existing colour coding as required at site complete all as specified for the following :-Make of wire : Polycab/ Gloster/ Anchor/ Havells/ Finolex and Make of PVC Conduit or Casing & caping : Modi/ Precision/ Supreme/ Finolex/ Polycab.Note :- The unit rate quoted shall deemed to include the cost of following :-(a) GI metal flush box of minimum thickness of 1.6mm and modular cover plate with frame of any module complete.(b) Proper colour coding is to be followed as per IS specification.(c) Wiring shall be concealed/ on surface with rigid PVC conduit medium grade/PVC casing caping as per site requirement.(d) Cutting chases in wall/floor /beam/ceiling to be concealed conduit and making good the disturbed surfaces.
89All as per item Sl No.88 above, but, for One light/fan point controlled by one modular switch 6 Amps one way complete all as specified and directed.
90All as per item Sl No.88 above, but, for one light point controlled by two modular switch 6 Amps two way complete all as specified and directed.
91All as per item Sl No.88 above, but , for one modular 3 pin 6 Amp socket out let on independent board complete all as specified and directed.
92All as per item Sl No.88 above, but, for one modular 3 pin 6 Amps socket outlet on same Board complete all as specified and directed.
93All as per item Srl No.88 above, but , point wiring with 4.0 sqmm PVC FRLSH insulated multistranded copper conductor suitable for one 3 pin 16 Amps socket out let and one run of 4.0 sqmm cable for earth in green colour on independent board complete all as specified and directed.
94S & F for switch modular type, 6 Amps 1 module, 230 volts AC circuit complete all as specified and directed.
95S & F for switch modular type,two way 6 Amps 1 module, 230 volts AC circuit complete all as specified and directed.
96S & F for socket outlet modular type 1 way 6 Amps, 3 pin, 230 volts AC circuit complete all as specified and directed.
97S & F for switch modular type, 16 Amps 1 module, 230 volts AC circuit complete all as specified and directed.
98S & F Socket outlet 2 in 1 modular type, 3 pin, 6 and 16 Amp , universal complete all as specified and directed.
99S & F stepped type electronic fan regulator modular type complete all as specified.
100S & F Ceiling rose PVC polycarbonate , isolated body 3 terminals 230 V complete all as specified and as directed.
101Supply & fix Modular AC Box With 20A DP MCB \\"C' Type, Metal Enclosure & Unbreakable Heavy Duty With ISI Plug Top, 240 volts AC supply for air conditioner, flush mounting in the wall complete all as specified and directed. Make:- Anchor (Roma) model no 98492 or equivalent to Havells/L&T
102Supply, installation, testing and commissioning (SITC) of 12 W recessed LED COB downlight , die-cast aluminium housing, integral LED driver, 3000 K Warm White, complete with mounting accessories, FRLS copper wiring from nearest junction box circuit complete all as specified and directed.Make :Havells or equivalent in /Wipro/Philips
103Supply, installation, testing and commissioning (SITC) of 24 V Warm White flexible LED strip light, 3000 K,14.4w/m complete with concealed in ceiling/shelves etc constant voltage LED driver, aluminium profile with opal diffuser, connectors, mounting clips, FRLS copper wiring, fixing accessories complete all as specified and directed.
104Supply, installation, testing and commissioning (SITC) of decorative suspended LED pendant light, 15–25 W, complete with integral LED driver, suspension cable/rod, ceiling canopy, connectors, FRLS copper wiring, fixing accessories circuit complete all as specified and directed.
105Supply, installation, testing and commissioning (SITC) of coloured RGB 14.4W/m controlled through rgb controller LED strip lighting (Blue/Pink), 24 V, complete with constant voltage LED driver, aluminium profile with diffuser, connectors, FRLS copper wiring, fixing accessories circuit complete all as specified and directed.
106Supply, installation, testing and commissioning (SITC) of LED Wall Washer luminaire, 18–24 W, IP65 protection, die-cast aluminium housing with powder-coated finish, high-efficiency LEDs, toughened clear glass, integral constant current LED driver, beam angle 30°/45°/60°, colour temperature 3000 K (Warm White), input voltage 220–240 V AC, complete with stainless steel adjustable mounting brackets, connectors, FRLS copper wiring from the nearest junction box, fixing accessories complete all as specified and directed.
107Taking down carefully ceiling fan/exhaust fan of any make, size from its location, dismantling complete, examine complete parts thoroughly, oiling, greasing all parts and complete overhauling of fan including replacement of small parts such as split pin, nut bolt, screws and assembling back the fan, make fully functional, rewinding and re-fixing the fan to its position including replacing and providing of twin core copper wire 23/0.0076 from fan to ceiling rose and painting the fan with same colour of fan complete all as directed.
108Supply and fixing ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC) complete all as specified and directed.
109Supply and fix exhaust fan 300 mm sweep suitable for working on 230 volts 50 hz supply incl taking down existing exhaust fan of complete all as specified and as directed.
110S & F of LED slim panel lighting fixture of 18/20 Watt recess/surface mounted 220V , 50Hz with finished in premium white powder coating ,environmental friendly energy efficient fitting recess mounted round/square in shape (Warm white/ white colour as per requirement of site complete) of light as required at site) complete all as specified and directed. Make - Luker/CG/ Philips/ Havells. NOTE: The rate quoted deemed to include for any alterations required to existing false ceiling as per site condition for fixing light fitting .
111Supply and fixing LED lights fitting 1x 22W, 220V,AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and as directed by Engineer-in-charge
112Supply and fixing LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and as directed by Engineer-in-charge
113S & F GI brackets of GI pipe light grade of size 32 mm dia including nuts, bolts and washers for building secufity light all as specified and directed
114M&L for Sub main wiring complete with two runs (1P+1N) of 1.5Sqmm single core, PVC insulated unsheathed, FRLSH cable, 1100 Volts grade, multistranded copper conductor (with colour coding of Red/Blue/Yellow for phase and Black for neutral) and one run of 1.5Sqmm single core, PVC insulated unsheathed, FRLSH cable, 1100 Volts grade, multistranded copper conductor as earth wire green in colour including lugs, drawn through and including 25mm wide rigid non-metallic PVC casing and capping and its accessories on surface of wall/ceiling/roof/floor complete all as specified and as directed.
115M&L for Sub main wiring complete with two runs (1P+1N) of 6.0 Sqmm single core, PVC insulated unsheathed, FRLSH cable, 1100 volts grade, multistranded copper conductor (with colour coding of Red/Blue/Yellow for phase and Black for neutral) and one run of 6.0 Sqmm single core, PVC insulated unsheathed, FRLSH cable, 1100 volts grade, multistranded copper conductor as earth wire green in colour including lugs, drawn through and including 25 mm wide rigid non-metallic PVC casing and capping and its accessories on surface of wall/ceiling/roof/ floor complete all as specified and as directed.
116S & F Sub main wiring with PVC insulated cable 2 single core 4 sq mm 1100 V grade with stranded copper conductor cable using proper colour coding Phase Red/Yellow/Blue, Neutral- black and earth- green in and incl rigid PVC conduit concealed/surafce in wall (ISI marked) incl all specials like joint elbow, Tee ,junction , bend etc and provision of PVC insulated copper conductor single core 4.0 sq mm for earth continuity all as specified and as directed.
117S & F DB VTPN sheet metal enclosure double door suitable for incoming upto MCCB 100 Amps/125 Amps & outgoing MCB TP / SP (IP-43) Protection Triple pole and neutral 415 V 4 Way with 200 Amp rated standard bus bar of suitable size plate and common neutral link all enclosed in standard steel sheet flush mounting type factory fabricated complete all as specified and directed.
118S & F single pole and neutral sheet steel powder coated Distribution board IP -43 protection with door earthing for MCBs fitted with 200 Amps rated bus bar , Neutral link ,Earth Bar and Din rail suitable for use on 240 V, 50 Hz supply double door SP&N DB system 08 ways,and making good to the distrubed surface /walls.
119S & F in replacement of MCCB, 4 pole, 125 Amps, 50Hz, 25KA rupturing capacity, 415 Volts adjustable type with thermal and magnetic release alongwith copper separator terminalscomplete all as specified and as directed.
120Supplying & fixing MCB SPN 32/40 Amps (`C’ series) having current rating 10 KA complete all as specified and directed .
121Supplying & fixing MCB single pole, 6 to 32 Amps (`C’ series) having current rating 10 KA complete all as specified and directed.Note for item No 113 to 114 :- All copper conductors should be connected with MCCB/ MCB alongwith copper reducer terminals of suitable size duly crimpled.”
122M&L for earthing complete with GI earth plate electrode of size 600mmx600mmx6mm thick buried directly in ground (earth pit not less than 2.25 m deep below the normal ground level) with top edge of the earth plate not less than 1.5 m below normal ground level connected to 4mm dia GI earth wire as earth lead connected by means of bolts, nuts, washers and check nuts made out of galvanised iron or steel all as shown on electrical plate No. 3 of SSR Part-I connected to common earth dolly including testing on completion complete all as specified and directed.NOTES: 1) The unit rate shall also include for earth work in any type of soil, PCC (1:3:6) type RCC chamber, pre-cast RCC (1:2:4) type B-1 using 20mm graded stone aggregate cover 50mm thick reinforced with TMT bars 8mm dia @ 100mm c/c both ways, funnel with watering pipe 20mm dia medium grade, GI protection pipe light grade 40mm dia and wire mesh complete in addition to item No. 1(a) to (e) of preamble (notes) under sub-heading earthing, specified on Sl. Page Nos. 422 & 423 of SSR Part-II. (2) Earthing lead and GI protection pipe beyond 7.5m will be measured and paid separately. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 58048604
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 43.40 Lakhs
LAST DATE 03-11-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Addition / Alteration To Building No P-73 (Navik Institute) At Coast Guard Under Ge Haddo, Sri Vijaya Puram
Basic Detail
Tender No 8399/E8
Bidding Type Tender
Location
City South Andamans
State Andaman And Nicobar Islands
Key Dates
Publish Date 14 Oct 2026
Submission Date 03 Nov 2026
Open Date 05 Nov 2026
Finance
Tender Value 43.40 Lakhs
Tender Fee 500
EMD 86800
Exemption Available
Document List
82fee6de-59a2-45b0-aceb-bd5c22be9b59.html
8399Tender.pdf
BOQ_890422.xls
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Oct 14, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Nov 03, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 7 days
Nov 05, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 9 days

Tender Documents

Download All (ZIP) ↓
html

82fee6de-59a2-45b0-aceb-bd5c22be9b59.html

pdf

8399Tender.pdf

xls

BOQ_890422.xls

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender