Tender For Special Repair To Bldg No T-69 (Cwm) At Mh, Roof Of Bldg No P-22 Jk Road And Certain Provision Wks In The Aor Of Age B/R-I Under Ge (North) Ahilyanagar.
Tender Value
48.23 Lakhs
Estimated cost
Bid Submission
04 Nov 2026
10 days left
EMD
96500
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Ahmednagar → Maharashtra
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Special Repair To Bldg No T-69 (Cwm) At Mh, Roof Of Bldg No P-22 Jk Road And Certain Provision Wks In The Aor Of Age B/R-I Under Ge (North) Ahilyanagar.
BOQ
| Sl. No. | Item Description |
| 1 | Taking down cement plaster on brick or concrete surfaces on wall/ceilling/stone/block etc including racking out joint, hacking for key, scrubbing down with water etc all as specified and as directed. |
| 2 | Demolition of brick work or stone/ boulder masonry/PCC block, built in cement mortar or cement lime mortar including all quoins, pillars etc. |
| 3 | Earth work in excavation by mechanical means (Hydraulic excavator)/ in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. |
| 4 | Earth work in excavation by mechanical means (Hydraulic excavator) means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5m, as directed by Engineer-incharge |
| 5 | Returning filling under floor including spreading, watring and well ramming in layer n.exc 25cm each in hard/dense soil. |
| 6 | Surface excavation n.exc (not exceeding) 30 cm deep and averaging 15cm deep and getting out soft / loose soil. |
| 7 | M&L for Excavating in post holes (or similar holes) each n exc 0.5 cu. m, getting out, in soft and loose soil returning,filling in and ramming earth or broken rubble mixed with earth around, removing surplus material n.exc 50 mtr and making good distrubed surface etc complete all as specified and directed by Engineer-in-Charge. |
| 8 | M&L for PCC 1:4:8 type D-2 (40mm graded aggregate) in foundation, sub base, filling and mass concrete. |
| 9 | M&L for Hardcore of broken stone of gauge n exc 63mm deposited, spreaded & levelled in layers n exc 15cm thick including watering and ramming etc complete. |
| 10 | M&L for Moorum filling in floors/pavings, laid in layers not exceeding 15 cm thick, spread, levelled and rammed/ rolled including watering to required level and gradient. |
| 11 | M&L for Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter flat rough finished complete all as specified and directed . |
| 12 | M&L for Formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including sup- ports, overhangs, etc. also splays between floors and beams, et. |
| 13 | M&L for Mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed. |
| 14 | M&L for Mild steel TMT bars in stirrups, spacers and binders for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed . |
| 15 | M&L for RCC (1:2:4) nominal mix type B1 using 20mm graded stone agregate Foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete complete all as specified and directed. |
| 16 | M&L for RCC (1:2:4) nominal mix type B1 using 20mm graded stone agregate Beams, cantilevers, bressummers, lintels over 1.5m span complete all as specified and directed . |
| 17 | M&L for 75 mm thick cement concrete type C-2, 1:3:6 (Using 40 mm graded aggregate) finishing cement concrete surface even and smooth without using extra cement as in plinth protection including joints and bitumen filling complete all as spd and directed. |
| 18 | M&L for 150 mm thick cement concrete type C-2, 1:3:6 (Using 40 mm graded aggregate) as in sub base complete all directed. |
| 19 | M&L for Brickwork with fly ash bricks, straight or curved on plan exc 6m mean radius, built in CM 1:6 complete all as specified and directed. |
| 20 | M&L for Brickwork with fly ash bricks, straight or curved on plan to any radius in half brick thick walls, built in CM 1:6 complete all as specified and directed . |
| 21 | M&L for flush pointing to random rubble masonry, uncoursed or brought upto courses CM 1:4. |
| 22 | M&L for rendering 20mm thick CM (1:4) on roof slab top, mixed with WPC finished even and fair without using extra cement complete all as specified. Note: WPC shall be measured and paid separately. |
| 23 | M&L for rendering 15mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:4, finished even and smooth without using extra cement with WPC.Note:- WPC shall be measured & paid seperately. |
| 24 | M&L for rendering 10 mm thick in CM 1:6 over brick surfaces, finished even and smooth without using extra cement all as specified and as directed. |
| 25 | M&L for preparing new plastered surfaces and applying Two coats of cement base paint over a coat of alkali resistant primer on surfaces of walls. |
| 26 | Supply only integral water proofing compound |
| 27 | M & L for applying two coats of OBD over a coat of primer on newly plastered wall surfaces over 2 coat of wall care putty after preparation of surfaces all as specified and as directed. |
| 28 | M&L for preparing old painted surfaces by washing, rubbing down and stopping of distempered and painted surfaces and applying two coat of distemper oil emulsion over putty and primer on surfaces of walls. |
| 29 | M&L for preparing old painted surfaces by washing, rubbing down and stopping of painted surfaces and applying two coat of cement base paint on surfaces of walls. |
| 30 | M&L for preparing the newly plastered or unplastered surfaces and applying two coats of cement based paint over one coat of alkali resistance priming paint over. |
| 31 | M&L for preparation of old painted wood and wood based surfaces of any description, not otherwise described, over 10 cm width or girth and applying one coat of Synthetic enamel paint (Ordinary tint). |
| 32 | M&L for preparing new surfaces of wood of any description over 10cm width or girth and apply two coats of synthetic enamel paint over a coat of pink primer all as specified and as directed. |
| 33 | M&L for two or more coat of Apex exterior paint of required colour shade on surface of walls including exterior primer complete all asw specified and directed by Engineer-in-Charge. |
| 34 | Demolition of Cement concrete (unreinforced) in ground floors and pavings n exc 15 cm thickness (below or above ground level) including floor finishes |
| 35 | M&L for 75 mm thick plain cement concrete 1:4:8 type D2, using 40 mm graded stone aggregate as in sub base all as directed. |
| 36 | Dismantling floor, hearth or wall tiling including cement mortar bedding and backing, removing serviceable tiles to store and removal of debries to a distance not exceeding 100m all as specified and as directed. |
| 37 | M&L for coloured Non - skid Ceramic tiles 7 to 8 mm thick (square/ rectangular) each tile 300 x 300mm / 400 x 400 mm in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match including Screed bed or bedding layer of mortar 15mm thick for laying floor finishes in cement mortar 1:6 complete all as specified and directed by Enggineer-in-charge. |
| 38 | M&L for Glazed ceramic coloured tiles in vertical surface 350x 250x 7 to 8 mm / 450X 350X 7 to 8 mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match including rendering 10 mm thick in CM 1:4 on fair faces of brick or concrete surfaces of wall as in backing of skirting and dado all as specified and as directed. |
| 39 | M&L for light shade Vitrified Ceramic tiles 8 to 10 mm thick (square/ rectangular) polished of each tiles 600 x 600 mm in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match including Screed bed or bedding layer of mortar 15mm thick for laying floor finishes in cement mortar 1:6 complete all as specified and directed by Enggineer-in-charge. |
| 40 | M&L for light shade Vitrified Ceramic tiles 8 to 10 mm thick (square/ rectangular) polished of each tiles 600 x 600 mm in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match including rendering 10 mm thick in CM 1:4 on fair faces of brick or concrete surfaces of wall as in backing of skirting and dado complete all as specified and directed by Enggineer-in-charge. |
| 41 | M&L for 18 to 20mm thick granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window -cills, cooking platforms and like in cement (1:4) including pointing in wihte cement (1:2) using marble dust with admixture of pigment ot match with shade of granite including moulding or rounding of edges, machine polishing to edge to give high gloss finish complete all as specified. |
| 42 | Demolition of stone slabs and tiles of any description or thickness laid bedded and pointed in any mortar in floors aprons etc. |
| 43 | M&L for 20 to 25 mm thick Rough dressed shahabad stone slab flooring, laid dry but jointed and pointed in cement mortar 1:3 including 15 mm thick screed bed in cement and sand mortar (1:6), etc complete all as specified and directed by Engineer-in-Charge. |
| 44 | Providing and laying 60mm thick factory made glossy finished chamfered edge cement concrete paver block of M-35 grade with approved colour, design & pattern as in footparth, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of fine sand (sand cushion), compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand;complete all as specified and directed by Engineer-in-Charge. |
| 45 | Providing and laying 80mm thick factory made glossy finished chamfered edge cement concrete paver block of M-30 grade with approved colour, design & pattern as in footparth, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of fine sand (sand cushion), compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand;complete all as specified and directed by Engineer-in-Charge. |
| 46 | M&L for Providing and laying at or near ground level factory made coloured kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5 mm), including making drainage opening wherever required complete all as specified and directed by Engineer-in-Charge. |
| 47 | M&L for 18 to 20mm thick machine cut kota stone flooring over Screed bed or bedding layer of mortar 15mm thick for laying floor finishes in cement mortar 1:6 laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and mirror polishing etc as directed by Engr-In-Charge. |
| 48 | M&L for 20 to 25 mm thick machine cut cudappah stone over cement screed bed laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and as directed. |
| 49 | Taking down of chowkat with shutter without taking off shutters from the frame exceeding 1.5sqm each but not exceeding 4 sqm all as specified and as directed. |
| 50 | Taking down of chowkat with shutter without taking off shutters from the frame not exceeding 1.5sqm all as specified and as directed. |
| 51 | S&F Aluminium framed windows / Doors / Ventilator any pattern, fixed/side hung/silding ( three track) using powder coated (50 Micron) alluminium sections, of approved make with or with out sash bars suitable for 4mm thick glazing including necessary jointed cleats,rubber bidding, glazing all as specified. Note-: (glazing shall be measured and paid separatly) |
| 52 | S&F for Anodised aluminium grill (anodised transparent or dyed to required shade according to IS: 1868 with minimum anodic coating of grade AC 15) of approved design/pattern, with approved standard section and fixed to the existing frame with C.P. brass/ stainless steel screws @ 200 mm centre to centre, including cutting the grill to proper opening size for fixing and operation of handles and fixing approved anodised aluminium standard section around the opening, all complete as per requirement and direction of Engineer in-charge. |
| 53 | S&F sheet glass ordinary quality 4.8 mm thick exceeding 0.5 sqm in each pane all as specified and as directed. |
| 54 | S&F sheet glass ordinary quality 4.8 mm thick not exceeding 0.5 sqm in each pane all as specified and as directed. |
| 55 | S&F sheet glass ordinary quality 4.0 mm thick with oil putty exceeding 0.5 sqm in each pane all as specified and as directed. |
| 56 | S&F in repairs stainless steel wire cloth 0.36 mm nominal dia of wire and average width of aperture 1.40 mm and fixed with stainless steel / wooden fillet / steel / aluminium frame all as specified and as directed. |
| 57 | S&F 30mm thick flush door shutter soild core construction with block board core and plywood face panels commercial type on both sides . |
| 58 | S&F second class hardwood glazed and skeleton shutters 35mm thick open rebated and prepared to receive glass gauge etc with sash bar divided into squares edges of framing plain chamfered or rounded fitted with cut and mitred beads for securing glass or gauze etc sizes of members of shutters as specified inSSR part-I section 8 clause 8.20 (a) fitted to chowkats . |
| 59 | S&F Solid PVC frame (Single Rebated) of size 60mm x 30mm made out of solid PVC foam with homogenous fine cellular structure having smooth outer integral skin with suitable metal stiffner and fixed with 100 x 8 sheet metal CSK screws complete all as specified and as shown on drawing (Note :- Door frame shall be water proof, termite proof, elegant and should have excellent screws holding strength to fix hinges and hold doors properly for a long life) |
| 60 | S&F Factory Made Solid PVC Moulded Door Shutter, 28 to 30mm thick (stiles), with 2, 4, or 6 raised panel design with 2mm thick Moulded PVC Sheet on the front face & 2mm plain colour PVC sheet on back face, with particle board coare supplying & fixing in frame at site as per specification & drawing on sl. page no. 181 of SSR part II 2020 |
| 61 | S&F butt hinge, stainless steel 100mm long all as specified and as directed. |
| 62 | S&F aluminium anodised sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded section and fixing bolt and sliding bolts of extruded sections or cast aluminium alloy 250 mm long and fixed all as specified and as directed. |
| 63 | S&F aluminium anodised sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded section and fixing bolt and sliding bolts of extruded sections or cast aluminium alloy 300 mm long and fixed all as specified and as directed. |
| 64 | S&F Floor door stopper of aluminium alloy body double and tongue anodised with rubber shoe and fixed of size 150 mm all as specified and as directed. |
| 65 | S&F aluminium anodised barrel tower bolt of extruded section 200 mm long and fixed all as specified and as directed. |
| 66 | S&F extruded aluminium alloy handle fabricated type anodised 150 mm long. |
| 67 | S & F in vitreous china wash basin, white back, nearest size 500 X 400 mm x 190 mm , errecting on existing CI brackets including taking down old one alll as specified and as directed. Note: If the mentioned size is not available in the market, the next immediate higher size shall be provided by the contractor. Make of Cera Code : S2040121 or others equivalent in approved make. |
| 68 | S&F in Vitreous China bowl urinal flat back, size of 465 x 355 x 265 mm white (minimum), with grating and union for discharge pipe waste pipe complete all as specified and as directed. |
| 69 | S&F 300 mm long, mild steel ordinary rat rail springs including roller and roller plate complete and taking down old one all as specified and as directed. |
| 70 | S & F of stainless steel curtain rods of dia 25mm and thickness of 1mm including brackets and knobs etc all as directed. |
| 71 | S & F of Harrison/curtain rails, stainless steel, chromium plated with fixing SS brackets, SS stops, SS rollers etc all as specifed and as directed by Engr-in-Charge. (All materials shall be stainless steel). |
| 72 | S&F in Double action floor spring hydraulically regulated made up of minimum 1.25 mm thick aluminium alloy sheet foundation box, main body with stainless steel cover, governing pivot made of brass, other parts made of mild steel heavy duty and fixed |
| 73 | S&F in repair aluminium extruded Door closer hydraulically regulated, designation No. 3, universal type, suitable for door shutters of 851 to 1000 mm in width and of weight between 61 to 80 kg and fixed. |
| 74 | Dismantling boarding, any description, fixed in wall or ceiling, any position with nails |
| 75 | S&F 25mm thick prelaminated particle board interior grade prelaminated one side with decorative choice lamination and other side balancing white lamination fixed with screws to timber frame work all as specified. |
| 76 | S&F Gl frame work for snap grid false ceiling including hangers 6 mm dia. G.I. (upto 1200mm length) adjusting level fixed to roof slabs by means of ceiling cleats made out of G.I. flat 40 x 3 mm size 60mm long and expansion hold fasteners 12.5mm dia. 40mm long complete all as specifiedall as specified as per manufacturere's instructions and all as directed. |
| 77 | S & F for GI interlocking snap grid 600mm x 600mm consists of main Tee runners of size 38mm x 25mm x 1.5mm and cross Tee of size 25mm x 25mm x 1.5mm, spaced between the main Tee at 600mm centre to centre to form a grid of 600mm x 600mm etc complete including GI wire hangars at 1200 mm intervals all as specified and as directed. |
| 78 | S&F 4mm thick non asbestos fibre cement building boards of make 'E Board classic designer board (Cascade or Occenic) of M/S Everest industries Ltd or equivalent as approved, fixed or laid/ inserted to timber/GI/Aluminium framework complete all as specified and directed . |
| 79 | Dismantling of Single layer Mangalore pattern or similar tiles in roofing including ridge complete all as specified. |
| 80 | S&F pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet of any colour 0.50mm thick (total coated thickness), 550 Mpa minimum, yield strength. It shall be coated with hot dip alloy of 55% Aluminium 43.5% Zinc 1.5% Silicon and finished with resin coat on both surfaces @ 150 gm/sqm of coating (total both surfaces) having overall width and laid width as specified and shall be fixed using hot dip galvanized, self drilling and self tapping screws neoprene and EPDM washers. Penetrations and laps in sheet shall be sealed by using proper sealant profile. HDPE fillers shall be provided wherever required to close voids between sheets, sheet & fasteners etc. complete all as directed. |
| 81 | S&F Pre-painted 0.50 mm thick plain, galvanised sheet in ridges, hips, valley gutters, drip and straight flashings (length and girth as fixed) with, 550 Mpa minimum, yield strength. It shall be coated with hot dip alloy of 55% Aluminium 43.5% Zinc 1.5% Silicon and finished with resin coat on both surfaces @ 150 gm/sqm of coating (total both surfaces) having overall width and laid width as specified and shall be fixed using hot dip galvanized, self drilling and self tapping screws neoprene and EPDM washers. Penetrations and laps in sheet shall be sealed by using proper sealant profile. HDPE fillers shall be provided wherever required to close voids between sheets, sheet & fasteners etc.complete all as specified and directed by Engineer-In-charge. |
| 82 | M&L for Filleting in repairs, in any position and to any shape exc. 25 sq. cm but not exc. 50 sq. cm in cement mortar 1:4 including all mitres, stops, etc. |
| 83 | Dismantling of asbestos cement (corrugated, semicorrugated, etc.) sheets in roof coverings including ridges etc complete all as specified and directed. |
| 84 | Dismantling of wrought iron or mild steel work of any description not otherwise provided for all as specified and directed. |
| 85 | S & F Rolled Mild Steel Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc. |
| 86 | S & F steel work in tubular trusses and tubular posts including special shaped washers etc., complete using but welded tubes confirming to IS 1161- 1979 graded St 240 with one shop coat of zinc chromate primer paint. |
| 87 | S&F for Plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, with riveted, bolted or welded attachment including two coat enamal paint over primer complete all as specified and as directed. |
| 88 | Taking down carefully existing unserviceable bitumen felt(any number of layers) including plaster of any thickness,wire brushing and cleaning of the surface of roof terraces including flashing and junctions of parapets kerb wall,PCC fillets,benching etc and removing of the rubbish to a distance not exceeding 500 M from the building and depositing where complete all as specified and directed. |
| 89 | Demolition of cement concrete of any description (Unreinforced) below or above ground floor incl concrete at junctions of parapets and roof terraces, flashings, Kerbs walls,PCC fillets, benching,coving of chajjah top/junctions etc complete all as specified and directed. |
| 90 | M &L for providing plain cement concrete 1:2:4 type B-0 (using 12.5 mm graded stone aggregate) for roof, kerb, or mud stops,rounded or chamfered on edges etc complete all as specified and as directed . |
| 91 | M & L for cleaning the newly plastered surfaces of concrete ( roof etc) with wire brushes and applying water proofing treatment as under :-i) Apply one coat of oil bound bituminous primer @ 0.25 kg/Sq.M ii) Providing and laying 3 mm thick APP modified water proofing membrane weighing not less than 3.5 Kg / Sqm reinforced with non woven polyester mat weighing not less than 160 gm/Sqm all as specified procured from any one of the approved manufacturer'siii) Apply one coat of solar reflective bituminous aluminium paint @ 0.15 Kg/Sqm over membrane over non assesble roof surfaces complete all as per manufacturer's instructions and as directed. |
| 92 | Dismantling water tanks and removing to store of capacity exc 500 & not exc 1000 ltrs. |
| 93 | Disconnecting existing tanks, setting aside (or lowering if required) for repairs, cleaning, etc. and hoisting if required reconnecting and re-fixing in position including Cleaning and removing all scale and dirt, etc, from tanks and from mouths of circulating pipes, etc |
| 94 | S&F for hoisting PVC tank of 1000 ltr capacity,white coloured,triple layer including Supplied and fixed 20mm dia PTMT with epoxy coated aluminium rod and high density plastic ball screwed for iron pipe and fixed.(Minimum weight 15mm-142 gms/20mm-210gms/25mm-455 gms/40mm-690 gms float valve assembly complete all as specified and directed. |
| 95 | S&F in repairs Gun-metal, globe or gate valves, 20 mm with iron wheel head, screwed both ends for iron pipe and fixed |
| 96 | S&F 20 mm Ball brass valves,high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule and fixed |
| 97 | Taking up or down steel tubing and connections, including cleaning for re-fixinf or removal to store 15 mm dia pipe complete all as specified . |
| 98 | Taking up or down steel tubing and connections, including cleaning for re-fixinf or removal to store 20mm dia pipe complete all as specified. |
| 99 | S&F 15 mm dia tubes medium grade galvanised, with all fitting and fixed complete to walls and ceilings or laid in floors complete all as specified. |
| 100 | S&F 20 mm dia tubes medium grade galvanised, with all fitting and fixed complete to walls and ceilings or laid in floors complete all as specified. |
| 101 | S&F stop valves cast copper alloy screwed down high pressure with crutch or butterfly handle, screwed both ends for iron pipe 15mm (fancy type chromium plated). |
| 102 | S&F in 15mm dia Chromium plated fancy type long body Bib tap cast copper alloy with crutch or butterfly handles screwed down screwed for iron pipe fixed in repair all as spd & directed . Make of Cera Code : F1015151 or others equivalent of approved make. |
| 103 | S&F in 15 mm bore fancy type Pillar taps, cast copper alloy, with capstan heads, chromium plated, screwed down high pressure, with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly-nuts, screwed for iron pipe and fixed complete all as specified and as directed Make of Cera Code : F1015101 or others equivalent of approved make. |
| 104 | S&F in 10 litres capacity PVC valveless, syphonic action type, flushing cistern, low level, white, with inlet, ball valve, float and handle including brackets and taking down old one complete all as specified and as directed. Make of Cera Code : B1010110 SN or others equivalent of approved make. |
| 105 | S&F in vitreous china squatting pan of orrisa pattern, size 580X 440x300 mm white, with integral foot rest 'P' or 'S' trap, complete all as specified and as directed. Make of Cera or others equivalent of parryware and Hindware. |
| 106 | S&F PVC connections 15mm size with PTMT nuts of length 450mm |
| 107 | S & F 110 mm bore PVC (SWR) Soil, waste and vent pipes single socketed in any length with rubber ring joints laid in trenches or in floors. |
| 108 | S & F 110 mm bore PVC (SWR) bends of any radius. |
| 109 | S & F 110 mm bore PVC (SWR) bends of any radius with access door. |
| 110 | S&F for PVC gully trap 125 / 110 mm , setting and jointing with solvent cement |
| 111 | S&F 75 mm bore PVC (SWR) Soil, waste and vent pipes single socketed in any length with rubber ring joints laid in floors or trenches. |
| 112 | S&F 75 mm bore PVC (SWR) Soil, waste and vent pipes single socketed in any length with rubber ring joints fixed to walls / floors. |
| 113 | S&F PVC (SWR) bends any radius 75mm bore |
| 114 | S&F 75 mm bore PVC (SWR) bends of any radius with access door. |
| 115 | S&F 75 mm bore PVC (SWR) Vent Cowl |
| 116 | S&F RCC Class NP 2, 150 mm bore pipes laid and jointed complete with collars. |
| 117 | M&L for PCC( 1:4:8) type D2 using 40 mm graded aggregate as in concrete bed to drain pipes 150 mm bore including packing under and haunching against the sides of pipes after they are laid and tested complete all as specified. |
| 118 | M&L for precast RCC 1:2:4 type B1 with 20mm graded aggregate as in man holes cover slabs set in cement mortar 1:6 complete all as specified and directed. |
| 119 | M&L for PCC (1:2:4) type B1 using 20 mm graded stone aggregate as in surface channels/drains, etc complete all as specified. |
| 120 | M&L for extra for forming fair finished drain or channel 30 cm inner girth in cement concrete using extra cement including forms, moulds, mitred/stopped end etc. |
| 121 | S&F for precast hume pipe septic tank of capacity 50 users incl necessary excavation & earthwork, RFR, removing of soil in any type of strata all as specified and directed by Engineer-in-Charge. |
| 122 | S&F mirror 600 x 450 mm of selected quality glass, mounted on 6mm thick AC building board or commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers. |
| 123 | Taking down carefully copper/aluminum point wiring (light/fan/bell/socket, power point etc) complete , including fixture and fitting such as switches, ceilling roses, pendants, regulators, sockets, light fittings etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per condition seperately) and making good disturbed surfases of walls, floors etc complete all as specified and directed Engineer-in-Charge |
| 124 | M&L for point wiring complete on surface of wall (open) type with two runs of 1.5 sq mm for phase and neutral single core multistranded copper conductor of 1100 volts grade PVC insulated and unsheathed FRLSH cable drawn in and incl PVC Casing and capping ISI Marked with its accessories PVC boxes (upto 12 module ) for fixing switches/socket/regulators etc incl 1.5 sq mm single core multistranded copper conductor of 1100 volts grade PVC insulated and unsheathed FRLSH cable as earth continuity conductor to common earth & connecting to earth dolly for the following, all as specified and directed. Note :1. Proper colour coding shall be adopted for wiring (For Phase- Red, Yellow, Blue, For Earth - Green and For Neutral- Black)2. All points are required to earthed upto fixtures i.e. Holders, Tube lights, Wall lights, ceiling lights, bulkhead lights, bldg security light etc |
| 125 | One light point/fan point/bell point controlled by switch 5 Amp single pole one way |
| 126 | One 3 pin 5 Amp socket outlet on same board controlled by one, one way 5 Amp switch |
| 127 | One socket outlet 5/3 pin 5 Amp controlled by one switch on independent board |
| 128 | .-ditto- all as per ser Item No 124 (here-in-before) but with 2.5 Sqmm Copper conductor cable for Phase , Neutral and Earth for one 3 pin, 15 Amp socket outlet on independent board |
| 129 | S&F Modular Switch, 6 Amp, one way, one Module. etc complete all as specified and directed by Engineer-in-Charge |
| 130 | S&F Modular Switch, 16 Amp, one way, one Module. etc complete all as specified and directed by Engineer-in-Charge |
| 131 | S&F Modular Socket Outlet 6 Amp, 3 pin, combined two module etc complete all as specified and directed by Engineer-in-Charge. |
| 132 | S&F Modular Socket Outlet 6 Amp / 16 Amp - 2/3 pin combined two module etc complete all as specified and directed by Engineer-in-Charge |
| 133 | S&F 36 watt panel 2x2 environmental friendly, new genration, aesthetically designed, ultra-modern recess mounting lumanaire with high brightness SMD LEDs as light source, suitable for Armstrong/ Grid ceiling, complete with seprate electronic driver ceiling light 36 watt with and including connecting up with & including twin core, twisted, flexible copper conductor cable of suitable size 23 volt, 50 HZ etc complete all as specified and directed by Engineer-in-Charge. |
| 134 | S&F ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1400 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC) complete all as specified and directed by Engineer-in-Charge |
| 135 | S&F switch piano flush type single pole, one way 5/6 Amp etc complete all as specified and directed by Engineer-in-Charge . |
| 136 | S&F ceiling rose 3 terminal / PVC / polycarbonate, isolated body etc complete all as specified and directed by Engineer-in-Charge |
| 137 | S&F in replacement Modular Fan Regulator Fan step regulator, 120 Watt - two module etc complete all as specified and directed by Engineer-in-Charge |
| 138 | Taking out/down and opening of existing ceiling fans 1200 mm sweep/exhaust fan of any size/electric meter from any position, of any make etc & refixing at the desired location after reassembling and after servicing/overhauling by thouroghly cleaning the shaft,r otor, stator and applying lubricant/ grease to bearings and one coat of super enamelled varnish over winding to improve the insulation resistance including repair /replacement of spare parts/ material /items, making connection by replacing PVC insulated unsheathed cable of copper conductor of size 1.50 Sqmm upto 0.50 Mtr length including using material/parts of minor nature such as screws, lugs, insulation tape, nuts, bolts, washers etc after cleaning the metal surface, greasing/lubricant etc to make it functional complete all as specified and as directed. |
| 139 | S&F energy saving and environmental friendly long life LED street light 35 Watt (Bldg security light) made up of pressure die cast aluminium housing with high efficiency LED as lighting source and lens embedded PC cover having bottom Opening seperate driver compartment with IP66 protection and impact resistance of IK08 fixed on wall with GI pipe bracket of suitable dia and all fixing accessories including connecting up with & including twin core twisted flexible copper conductor cable of suitable size of 230V , 50 HZ etc complete all as specified and directed by Engineer-in-Charge. |
| 140 | S&F in replacement energy saving and environmental friendly long life LED street light 45 Watt (Bldg security light) made up of pressure die cast aluminium housing with mild power LED as lighting source and PC cover having TOP Opening seperate driver compartment with IP65 protection and impact resistance of IK07 fixed on wall with GI pipe bracket of suitable dia and all fixing accessories including connecting up with & including twin core twisted flexible copper conductor cable of suitable size of 230V , 50 HZ etc complete all as specified and directed by Engineer-in-Charge. |
| 141 | S&F reolacement Double door Sheet metal enclosures factory made DBs SPN, 8 way, 240 volts, protection class IP-42, suitable for fixing of MCBs, confirming As per IEC 61439-3, Suitable for Flush Mounting and Surface Mounting, With 200 A Copper Busbar, With Neutral bar, Earthbar and Cable ties for Cable management, Fully shrouded Neutral bars, Prefitted masking sheet complete all as specified and as directed.Note:- MCBs will be measured and paid separately. |
| 142 | S & F in replacement double door Sheet metal enclosures factory made DBs SPN,4 way, 240 volts, protection class IP-42, suitable for fixing of MCBs,, confirming As per IEC 61439-3, Suitable for Flush Mounting and Surface Mounting, With 100 A Copper Busbar, With Neutral bar, Earthbar and Cable ties for Cable management, Fully shrouded Neutral bars, Prefitted masking sheet complete all as specified and as directed. |
| 143 | S&F exhaust fan,PVC body AC Single phase, 230 V of size 200 mm sweep with, blades frame and louvers. |
| 144 | S&F Industrial type ultra slim square profile LED lighting fixture, environmental friendly, energy efficient ready to use pack LED Tube light fitiing 20 Watt with LED light source 6500 K with uniform light output, with all accessories including its connection with and including 2 core sheathed copper conductor cable of size 0.5 Sqmm with complete with all accessories etc complete all as specified and directed by Engineer-in-Charge. |
| 145 | S&F Decorative ultra slim square profile LED lighting fixture with extruded polycarbonate, environmental friendly, energy efficient ready to use pack LED Tube light fitiing 20 Watt with LED light source 6500 K with uniform light output, with all accessories including its connection with and including 2 core sheathed copper conductor cable of size 0.5 Sqmm with complete with all accessories etc complete all as specified and directed by Engineer-in-Charge. |
| 146 | S&F MCB, SP, AC, 240 Volts of 06 to 32 Amp capacity 10 KA, 'B' series and making connections with suitable size of copper lugs etc complete all as specified and directed by Engineer-in-Charge. |
| 147 | S&F MCBs, SPN, AC, 240 volts of 32 Amps capacity 10 KA, 'C' series and making connections with suitable size of copper lugs etc complete all as specified and directed by Engineer-in-Charge. |
| 148 | Supply & fixing MCB , SP, AC, 240 Volts of 06 to 40 Amp capacity 16 KA, 'C' series and making connections with suitable size of copper lugs etc complete all as specified and directed by Engineer-in-Charge. |
| 149 | S&F MCBs, SPN, AC, 240 volts of 40 Amps capacity 16 KA, 'C' series and making connections with suitable size of copper lugs etc complete all as specified and directed by Engineer-in-Charge. |
| 150 | S&F sub main wiring with two single core PVC insulated, unsheathed, FRLSH stranded copper conductor cable 2.5 Sqmm with 1.5 Sqmm PVC insulated, unsheathed, FRLSH stranded copper conductor cable as earth wire drawn through and including PVC Casing and capping ISI Marked with its all necessary accessories and earth wire connected to common earth dolly etc complete all as specified and directed by Engineer-in-Charge Note :1. Proper colour coding shall be adopted for wiring (For Phase- Red, Yellow, Blue, For Earth - Green and For Neutral- Black)2. Two run of 2.5 Sqmm cable i.e for one run for phase, one run for neutral with one run of 1.5 Sqmm cable for earth and one run of PVC Casing & caping shall be measured as one unit. |
| 151 | S&F sub main wiring with 4 Sqmm single core,2 Run PVC insulated,unsheathed, FRLSH stranded copper conductor cable with 4 Sqmm,one Run PVC insulated, unsheathed, FRLSH stranded copper conductor cable as earth wire drawn through and including Concealed in wall with its all necessary accessories and earth wire connected to common earth dolly etc complete all as specified and directed by Engineer-in-Charge. Note :1. Proper colour coding shall be adopted for wiring (For Phase- Red, Yellow, Blue, For Earth - Green and For Neutral- Black)2. Two run of 4 Sqmm cable i.e for one run for phase, one run for neutral with one run of 4 Sqmm cable for earth and one run of PVC Conduit shall be measured as one unit. |
| 152 | M&L for earthing complete with galvanised steel earth plate electrode 600x600x6mm thick burried directly in ground. Earth pit not less than 2.25mtr depth and top edge of the earth plate not less than 1.5mtr below normal ground level connected to galvanised earth lead wire 4.0Sqmm dia by means of nuts,bolts & washer etc. Earth wire connected upto main earth point/DBs alongwith 15mm dia earth protection pipe from top edge of the earth plate to main earth point to be connected and 20mm dia watering pipe light grade with funnel and provn of PCC using cement concrete (1:2:4) mix type B1 ( using 20 mm graded stone agregate) and RCC pit cover 50 mm thick precost RCC (1:2:4) mix type B1 duly reinforced with 8 mm dia of ms bar @ 15 mm CIC with both way lifting arrangement complete including all necessary excavation & earth work all as specified and directed. |
| 153 | M & L for Supply, laying, connecting, testing and commissioning and jointing, LT underground cable in replacement, 1100 volts grade, XLPE insulated, armored with galvanized round steel wire or steel strip, electric power cables heavy duty, with multi stranded aluminum conductor, laid in ducts, fixed on poles/walls with proper size saddles and clamp complete all as specified and as directed by the Engineer-in-Charge of following Sizes :- (a) LT cable 10 Sqmm, 2 core.Note : Excavation & Earthwork, pipe protection shall be measured & paid separately under the relevant item of this Schedule. |
| 154 | Excavation in trenches n. exc 1.5 m wide and n. exc 1.5 m in depth and getting out in hard/dense soil etc complete all as specified and directed by Engineer-in-Charge |
| 155 | Removing exacavated soil to a distance n. exc 50 m and depositing where directed at a level n. exc 1.5 m above the starting point etc complete all as specified and directed by Engineer-in-Charge. |
| 156 | Supply & lay HDPE pipe 50 mm bore for laying of LT cable complete with all accessores etc complete all as specified and directed by Engineer-in-Charge |
| 157 | Cutting to existing CI/GI pipe line upto 80 /50/25 mm dia for taking connection up to 25 mm dia GI pipe including insertion of CI / GI Tee including Exc & earth Work complete all as specified and directed. |
| 158 | Supply and lay in trenches/or on wall medium grade steel water tubing galvanised with all fittings and joints etc complete for size :- (a) 20 mm boreNote : Excavation & Earthwork shall be measured & paid separately under the relevant item of this Schedule. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Oct 14, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedNov 04, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 10 daysNov 06, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 12 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender