Tender For Servicing/Maintenance And Call On Repairs For 24 Hrs And Other Allied Works For 11 Kv Ht Vcbs Panels At Old Dockyard Substations At Naval Dockyard Visakhapatnam Under Ge (I) (Dm) Visakhapatnam

Issued by Statutory Bodies & Commissions/Committees · Visakhapatanam, Andhra Pradesh
Tender Value
45.40 Lakhs
Estimated cost
Bid Submission
04 Nov 2026
6 days left
EMD
90800
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Visakhapatanam → Andhra Pradesh
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Servicing/Maintenance And Call On Repairs For 24 Hrs And Other Allied Works For 11 Kv Ht Vcbs Panels At Old Dockyard Substations At Naval Dockyard Visakhapatnam Under Ge (I) (Dm) Visakhapatnam

BOQ

Name of Work:- SERVICING/MAINTENANCE AND CALL ON REPAIRS FOR 24 HRS AND OTHER ALLIED WORKS FOR 11 KV HT VCBS PANELS AT OLD DOCKYARD SUBSTATIONS AT NAVAL DOCKYARD VISAKHAPATNAM UNDER GE (I) (DM) VISAKHAPATNAM
Sl. No. Item Description
1Attending day to day complaints and call on repair for 24 Hrs of HT Switchgear Vacuum Circuit breaker of capacity 630A to 1250A Schneider make with one Engineer , one electrician and one helper for all days including Holidays & Sundays for opening of covers, checking for any uncertainty and refixing the same to original position, re-connection of all existing cables, extended bus bars, after rectification & testing , closing the complaint by re-energising the feeder complete all as specified and as directed.Note: Replacement of defective parts shall be measured and paid separately.
2Taking down HT Switch gear vaccum circuit breaker of capacity 630 Amps to 1200 Amps, 12kv/11KV, Schneider make HWX Model for carrying out following repairs, overhaluing, servicing, preventive maintenance and reflixing the same after carrying out repairs / overhauling complete all as specified and as directed.(a) Tripping off the breaker, rackout the breaker complete from the panel along with trolly for servicing / inspection/ overhauling.(b) Servicing / inspecting/ checking automatic safety shutter operation for service ability and replacement of spares if required.(c ) Servicing /inspecting / checking of busbar spout and circuit spout connections for RYB Phases and replacement of spares if required.(d) checking of breaker ma9in mechanism assembly, fixed contacts and cuurrent carrying parts of the breaker, trolley, insulated asembly etc.(e) setting, reassembling, cleaning adjustment of fixed contacts main contact, acring contact and moving contact for proper setting of auxiliary contacts operatingg mechanism.
3(f) Servicing / inspecting / checking of secondary socketd / busbar earthing plugs / earthing sockets and replacement of spares if required.(g) checking, setting and adjustment of rackin and rackout operation of the breakedr trolley.(h) Decarbonising of busbar and connected items.(j) Lubrication and greasing of all moving parts of the trolley, stopper bolt for proper operating.Note:(a) The rate quoted shall be deemed to be include for necessary T & P, Nuts, bolts, washers, gasket, insulation tape, HT Sleeve, monoplast compound to put in to the VCBs and paneles in serviceable condition, testing and commissioning(b) Replacement of defective parts of the VCB Shall be measured and paid separately.
4Maintenance, servicing, cleaning of vacuum circuit breaker unit of 11 KV VCB panel of capacity 630 Amps to 1250 Amps, taking out from panel, cleaning of all parts with CTC and clean cloth, removal of carbon deposited inside the moving contacts, greasing of all moving parts of the VCB, checking of complete operating mechanism for proper functioning, reporting for any defective parts, complete all as specified and as directed. Note: Replacement of defective parts of the VCB shall be measured and paid separately.
5Supply and fix including dismantling taking out unserviceable Buffer (For Opening Spring ) For 630 Amps to 1250 Amps Schneider make 11 KV VCB. All as specified and directed.Make : - Schneider only, Part No- MVIJ00098-01 .
6Supply and fix including dismantling taking out unserviceable Buffer (For Closing Spring ) For 630 Amps to 1250 Amps Schneider make 11 KV VCB all as specified and directed. Make :- Schneider only, Part No- MVIJ00056-01
7Supply and fix single (Read-Blue) phase busbar spout suitable for 630 Amps to 1250 Amps VCB make Schneider only Model No MEP-39-32185 complete all as specified and as directed.
8Supply and fix single (Y) phase busbar spout for 630 Amps to 1250 Amps VCB make Schneider only Model No MEP-39-32186 complete all as specified and as directed.
9Supply and fix CT Spout suitable for VCB 630 Amps to 1250 Amps complete all as specified and as directed.Make :- Schneider only, Model No MEP-39-32187
10Supply & fixing closing coil assembly 110 V DC to Schneider make 11KV VCB incl necessary connection testing complete including dismantling taking down unsv one complete all as specified and as directed. Make :- Schneider only, Part No- ECO39SN134900FN
11Supply and fixing tripping coil 110 V DC to Schneider make 11KV VCB including necessary connection testing complete incl dismantling taking down unsv one complete all as specified and as directed.. Make :- Schneider only , Part No- ECO39SN134100FN
12Supply and fix including dismantling taking out unserviceable Service /Test Position Limit Switch 1NO+1NC For 630 Amps to 1250 Amps Schneider make 11 KV VCB complete all as specified and directed.Make :- Schneider only, Part No- ESW-B-AAA00-001
13Supply and fix including dismantling taking out unserviceable Breaker Wheel - CAST IRON, For 630 Amps to 1250 Amps Schneider make 11 KV VCB all as specified and directed. Make :- Schneider only, Part No-MVIA00025-01
14Supply and fix including dismantling taking out unserviceable spring charging Universal motor with gear box 220V AC For 630 Amps to 1250 Amps Schneider make 11 KV VCB all as spcified and directed.Make :- Schneider only, Part No-MVIJOO157-02
15Supply and fix including dismantling taking out unserviceable vacuum interrupter of suitable for VCB of capacity 630 Amps to 1250 Amps all as specified and directed.Make :- Schneider VSLVG3002-01 or DRCVG2002-01 as per existing
16Supply and fix including dismantling taking out unserviceable busbar supporting insulator for 630 Amps to 1250 Amps Schneider make 11 KV VCB all as specified and directed.Make :- Schneider only , Part No- MEP-39-A0147901
17Supply and fix including dismantling taking out unserviceable Rectifier unit (Monoblock) for spring charging motor For 630 Amps to 1250 Amps Schneider make 11 KV VCB all as specified and directed.Make :- Schneider only, Part No- ERC-A-A00DC-001
18Supply and fix Drive Beam suitable for 11 KV VCB 630 Amps to 1250 Amps all as specified and directed.Make :- Schneider only Model No MSM3950118600FN
19Supply and fix including dismantling taking out unserviceable Isolating Contact for 630 Amps to 1250 Amps Schneider make 11 KV VCB complete all as specified and directed.Make :- Schneider only, Part No- MVIK00190-01
20Supply and fix Epoxy Body suitable for 11 KV VCB 630 Amps to 1250 Amps make Schneider only, Model No MEP3953022000FN-22 complete all as specified and as directed.
21Supply and fix Shutter assembly for busbar / circuit spout suitable for 11 KV VCB 630 Amps to 1250 Amps all as specified and directed.Make :- Schneider only Model No SPP0009-04
22Supply and fix space heater, 230V, 100 watt inside cable chamber including necessary connection, testing complete all as specified and as directed. Make :- Schneider, Part No-EHT-A-AA 000-001
23Supply and fix including dismantling taking out unserviceable thermostat for space heater For 630 Amps to 1250 Amps Schneider make 11 KV VCB all as specified and directed. Make :- Schneider only, Part No- ETH-E-B000-001
24Supply and fix including dismantling taking out unserviceable resin cast CT dual core of ratio 100-50/5A-5A/15VA core 1 metering, core 2 protection of breaking capacity 31.5KA with dimension 220x110x230 mm and hole to hole 110 mm for 800 to 1250 A Schneider make 11 KV VCB all as specified and directed.Make : Kappa/Esun/ Pragati/AE/ SCHENIDER/Plastofab Note : Contractor should visit the site for brackets size to mounting the CTs in 11 KV VCBs.
25All as per item No 23.00 above, but 400-200/5A-5A/15VA 5P10
26All as per item No 23.00 above, but 600-300/5A-5A/15VA 5P10
27M&L for THERMOGRAPHIC TESTING of 11kV switch Boards with IMAGE INFRARED CAMERA to detect Hot spots, to avoid electrical failures and increase safety for all current-carrying devices. Visual and Mechanical Inspection to be done when load is applied to the system. Use & follow appropriate caution, safety devices, and personal protective equipment. Provide a report which includes the following:1. Description of equipment tested. 2. Discrepancies if any.(HOT Spots).3. Identify load conditions at time of inspection. 4. Provide photographs and/or thermo grams.
28M&L for painting of outer surface of multiple section of complete VCB panel 11 KV size upto 2m x 1.8 x 0.8 in one substation using one coat of synthetic zinc paint after preparation of surface, providing protection cover to all metering equipment, panel meters, switchgears, cleaning of all meters and switch gears all as specified and directed.
29Decarburizing/Buffering of copper Busbar complete from 11kV HT Bus bar chamber of each VCB panel including connecting Busbar from CT to main Busbar & spout. Servicing of support insulator by clean cloth and hot air blower/ vacuum cleaner, applying Backtol Red solution to the bus bar insulator , checking for any loose contact, refixing of all nuts & bolts by Stainless steel , refixing all covers ,replacement of defective parts, busbar sleeve and ensure proper decarburizing up to proper megger value , checking all the connections all as specified and directed.
30Supply and fixing of complete PT set, including dismantling taking out complete unserviceable drawout type PT trolly set , PT of 100 VA, dual core of ratio 11KV/root3/110V/root3/100VA , Insulation class F, core 1 metering, core 2 protection.Make : Kappa/Esun/ Pragati/AE/SCHENIDER/Plastofab/AudioVision or approved by engineer-in-charge complete all as specified and as directed.Make : Kappa/Esun/ Pragati/AE/SCHENIDER/ Plastofab cNote : Contractor should visit the site for brackets size to mounting the PTs in 11 KV VCBs.
31Supply and fix including dismantling taking out unserviceable HRC Fuse-Pt HT Side (VTF-11, 3A) For 800A to 1600A Schneider make 11 KV VCB complete all as specified and directed.Make-Schneider/AudioVision/ANNAND/ UNITY/BUSSMANN
32M&L for maintenence/servicing of PT unit 11Kv / 110V by disconneting and taking out from panel mounted position, checking & cleaning of fixed and moving contact points, cleaning/ decarbonising of busbar connections, resin cast PTs using hot blower, CTC solution to the epoxy PT body, tightening of all nuts, bolts, washers, and refixing the same PT to original position, testing complete all as specified and directed.
33Supply and fix PT Spout suitable for VCB Panel 800 to 2500 Amps , along with connected busbars/cables complete all as specified and as directed.Make : Kappa/Esun/ Pragati/AE/ SCHENIDER/ Plastofab
34Supply and applying Si-COAT 570 RTV Silicone High Voltage Insulator Coating solution using an Sprayer to the 11KV Indoor VCB panel Cable chamber (4.5 Kg coating materials per panel) , testing complete all as specified and directed.Make:- CSL Silicones Inc. Canada
35Supply and applying Si-COAT 570 RTV Silicone High Voltage Insulator Coating solution using an Sprayer to the 11KV Indoor VCB panel Bus bar chamber (4 Kg coating materials per panel) , testing complete all as specified and directed.Make:- CSL Silicones Inc. CanadaNote for item Nos. 33.00 & 34.00 :- (i) Surface preparation: All insulation surfaces of the equipment to be coated shall be made free from dust, grease, oil and any other foreign material without damaging the surface. The surface of the equipment shall be made dry before application of the RTV coating.(ii) All the required materials, tools & tackles, testing equipment, consumables etc. for application of HVIC coating shall be in bidders’ scope Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 58048579
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 45.40 Lakhs
LAST DATE 04-11-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Servicing/Maintenance And Call On Repairs For 24 Hrs And Other Allied Works For 11 Kv Ht Vcbs Panels At Old Dockyard Substations At Naval Dockyard Visakhapatnam Under Ge (I) (Dm) Visakhapatnam
Basic Detail
Tender No 8711/C/E8
Bidding Type Tender
Location
City Visakhapatanam
State Andhra Pradesh
Key Dates
Publish Date 14 Oct 2026
Submission Date 04 Nov 2026
Open Date 06 Nov 2026
Finance
Tender Value 45.40 Lakhs
Tender Fee 500
EMD 90800
Exemption Available
Document List
8711Tender.pdf
b0f5f4ea-3887-47f6-abdc-c791ee305df9.html
BOQ_890358.xls
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Oct 14, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Nov 04, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 6 days
Nov 06, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 8 days

Tender Documents

Download All (ZIP) ↓
pdf

8711Tender.pdf

html

b0f5f4ea-3887-47f6-abdc-c791ee305df9.html

xls

BOQ_890358.xls

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender