Defence Statutory Bodies & Commissions/Committees Closing in 23 days TDR #58048578

Tender For special Repair/Replacement Of Two/Four Str With Ht Vcb At Main Power House At Hq And special Repair Of Ht Switch Gear With Underground Cable At Csr Under Ge (S) Tezpur

Issued by Statutory Bodies & Commissions/Committees · Sonitpur, Assam
Tender Value
84.50 Lakhs
Estimated cost
Bid Submission
11 Nov 2026
23 days left
EMD
1.51 Lakhs
Bank guarantee accepted
Document Fee
1000
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Sonitpur → Assam
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for special Repair/Replacement Of Two/Four Str With Ht Vcb At Main Power House At Hq And special Repair Of Ht Switch Gear With Underground Cable At Csr Under Ge (S) Tezpur

BOQ

Name of Work:- SPL REPAIR/REPLACEMENT OF TWO/FOUR STR WITH HT VCB AT MAIN POWER HOUSE AT HQ AND SPL REPAIR OF HT SWITCH GEAR WITH UNDERGROUND CABLE AT CSR UNDER GE (S) TEZPUR
Sl. No. Item Description
1Supply, laying and testing of cable XLPE (E) insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) with stranded aluminium conductor, 11000 Volts grade, cross sectional area 95 Sqmm 3 core complete all as specified and directed.
2Supply, laying and testing of cable XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) with stranded aluminium conductor, 1100 Volts grade, cross sectional area 300 Sqmm 3.5 core complete all as specified and directed.
3Supply, laying and testing of cable XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) with stranded aluminium conductor, 1100 Volts grade, cross sectional area 185 Sqmm 3.5 core complete all as specified and directed.
4Supply, laying and testing of cable XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) with stranded aluminium conductor, 1100 Volts grade, cross sectional area 120 Sqmm 3.5 core complete all as specified and directed.
5Supply, laying and testing of cable XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) with stranded aluminium conductor, 1100 Volts grade, cross sectional area 95 Sqmm 3.5 core complete all as specified and directed.
6Excavation in trenches, in any type of soil not exceeding 1.5 Mtr wide and not exceeding 1.5 Mtr in depth , laying of cable or pipes (where provided for protection of cable) etc and getting out trimming the sides, forming bottom surfaces to required level complete all as specified and all as directed.
7Returning and filling including spreading, levelling, watering and well ramming in layers not exceeding 25 Cm thick all as specified and directed by Engr-in-Charge.
8Removing of surplus soil to a distance not exceeding 50 Mtrs and depositing where directed at a level not exceeding 1.5 Mtr above the starting point complete all as specified.
9M&L for 100 mm dia GI tubing light grade with all necessary fittings laid in trenches, fixed to walls/ poles/ under road/ floor etc for cable protection, complete all as specified and directed.
10M & L for sand cushioning with a layer of sand 80 mm thick before laying of cable and 150 mm thick after laying of cable in trenches complete all as specified and directed. (Note- Sand cushioning shall be measured and paid after punning)
11Supply and laying of well burnt bricks, sub class 'B' laid flat in trenches for protection of cable complete all as specified and directed.
12Supplying and laying un-reinforced precast concrete cable cover, but class HV, Type 1, flat, size 300mmx 180mm x 40mm complete all as specified and directed.
13Supply and fix cable jointing kit for 11 KV grade cable for indoor termination cold shrink type joint complete with jointing material and accessories suitable for 3 core XLPE, armoured, Al conductor cable of size 95 Sqmm
14Supply and fix cable jointing kit for 11 KV grade cable for out door termination cold shrink type joint complete with jointing material and accessories suitable for 3 core XLPE, armoured, Al conductor cable of size 95 Sqmm
15Supply, installations , testing & commissioning of 11 KV of rating 630 Amp RMU unit outdoor type (IP-54) protection duly painted(Paint shade in painted Alu Zn/RAL 7032 on sheet steel for door and covers), VCB type | RMU( RING Main unit) Four way comprising of three numbers insulated load break switch as outgoing and one number Vacuum Circuit Breaker as incoming inside . RMU should be provided with Copper Bus bar , one number fault passage indicator with each incoming and outgoing mechanism for interlocking arrangements for powered relay complete with all accessories as under. (a) RMU type installation Outdoor Extensible type, arc proof as per IEC : 62271-200 for design Manufacturing and testing . The RMU must have the following features/specification:- INCOMER :- VCB should have following specification :- (i) Rated Voltage upto -12KV (ii) Rated power frequency withstand voltage -28KV (iii) Rated lighting impulse withstand voltage —should ibe minimum 125KVP (iv) Rate d current for ring main feeder -630A (v) Rated current for VCB feeder -630A (vi) Rated short-time current-21 KA/3 Sec(vii) Rate Short making current -50 KA (viii) Ambient temperature (-1 degree Celsius to +45degree Celsius), (ix) Degree of protection against accidental contact and ingress of foreign objects must be assured as under:- Please Enable Macros to View BoQ information
16Supply, installations , testing & commissioning of 11 KV of rating 630 Amp RMU unit outdoor type (IP-54) protection duly painted(Paint shade in painted Alu Zn/RAL 7032 on sheet steel for door and covers), VCB type | RMU( RING Main unit) Four way comprising of three numbers insulated load break switch as outgoing and one number Vacuum Circuit Breaker as incoming inside . RMU should be provided with Copper Bus bar , one number fault passage indicator with each incoming and outgoing mechanism for interlocking arrangements for powered relay complete with all accessories as under. (a) RMU type installation Outdoor Extensible type, arc proof as per IEC : 62271-200 for design Manufacturing and testing . The RMU must have the following features/specification:- INCOMER :- VCB should have following specification :- (i) Rated Voltage upto -12KV (ii) Rated power frequency withstand voltage -28KV (iii) Rated lighting impulse withstand voltage —should ibe minimum 125KVP (iv) Rate d current for ring main feeder -630A (v) Rated current for VCB feeder -630A (vi) Rated short-time current-21 KA/3 Sec(vii) Rate Short making current -50 KA (viii) Ambient temperature (-1 degree Celsius to +45degree Celsius), (ix) Degree of protection against accidental contact and ingress of foreign objects must be assured as under:- Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 58048578
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 84.50 Lakhs
LAST DATE 11-11-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for special Repair/Replacement Of Two/Four Str With Ht Vcb At Main Power House At Hq And special Repair Of Ht Switch Gear With Underground Cable At Csr Under Ge (S) Tezpur
Basic Detail
Tender No 8323/TEZ(S)/E8
Bidding Type Tender
Location
City Sonitpur
State Assam
Key Dates
Publish Date 14 Oct 2026
Submission Date 11 Nov 2026
Open Date 16 Nov 2026
Finance
Tender Value 84.50 Lakhs
Tender Fee 1000
EMD 1.51 Lakhs
Exemption Available
Document List
071172c8-fe90-494f-90d7-49275fc32820.html
BOQ_890312.xls
Makes.rar
tenderdocus.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Oct 14, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Nov 11, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 23 days
Nov 16, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 28 days

Tender Documents

Download All (ZIP) ↓
html

071172c8-fe90-494f-90d7-49275fc32820.html

xls

BOQ_890312.xls

rar

Makes.rar

pdf

tenderdocus.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender