Defence Statutory Bodies & Commissions/Committees Closing in 18 days TDR #58048575

Tender For Addn/Altn To Bldg No. A-56 (Or Single Living Accn) Alongwith Replacement Of Tiles At Signal Unit, Happy Valley And Provn Of 02 X Septic Tank And Soak Well For Sentry Post No. 1 And Post No. 2 At Signal Unit Happy Valley Under Ge Shillong

Issued by Statutory Bodies & Commissions/Committees · East Khasi Hills, Meghalaya
Tender Value
46.68 Lakhs
Estimated cost
Bid Submission
04 Nov 2026
18 days left
EMD
93360
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
East Khasi Hills → Meghalaya
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Addn/Altn To Bldg No. A-56 (Or Single Living Accn) Alongwith Replacement Of Tiles At Signal Unit, Happy Valley And Provn Of 02 X Septic Tank And Soak Well For Sentry Post No. 1 And Post No. 2 At Signal Unit Happy Valley Under Ge Shillong

BOQ

Name of Work:- ADDN/ALTN TO BLDG NO. A-56 (OR SINGLE LIVING ACCN) ALONGWITH REPLACEMENT OF TILES AT SIGNAL UNIT, HAPPY VALLEY AND PROVN OF 02 X SEPTIC TANK AND SOAK WELL FOR SENTRY POST NO. 1 AND POST NO. 2 AT SIGNAL UNIT HAPPY VALLEY UNDER GE SHILLONG
Sl. No. Item Description
1S&F Pre-painted galvalume aluminium zinc coating GI based corrugated/Semi Corrugated steel sheet 0.50 mm thick of an colour having tensile strenngth of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws including dismantling of plain/corrugated steel sheeting any gauge, thickness in roof covering complete all as specified and directed.
2S&F Pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50 mm thick of an colour having tensile strenngth of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws including dismantling of plain/corrugated steel sheeting any gauge, thickness in roof covering complete all as specified and directed.
3S&F 2nd class HW boarding 20mm thick fixed with nails as in eaves board planed one side with butt joint including dismantling boarding of any description complete all as specified and as directed.
4M&L for water proofing treatment to RCC roof slab, including parapet comprising with the following courses of treatment/specification from bottom to top:-(i) Taking out old roof treatment and roughening the same old concrete slab by picking, sweeping clean and washing down with water to remove dust etc.and applying cement slurry @3kg/Sqm(ii) Screed bed or bedding layer of mortar 1:4 in 15 mm thick for laying as in roof slab with mixing of WPC and surface finished fare and smooth without using extra cement. (Note: WPC shall be measured and paid for under separate items)(iii) Cleaning of plastered roof surface and applying one coat of cold bituminous primer @ 0.25ltr /Sqm conforming to IS:3384-1986.(iv) APP based polymeric membrane 3mm thick (minimum), weighing 3.5 Kg/sqm reinforced with polyester non woven fabric (weighing not less than 160 gms/Sqm) shall be less applied over bituminous primer as specified above over a Application of polymeric membrance shall by torch application. The overlaps shall be minimum 100mm on the transverse direction and 75mm on longitudinal direction.(v) Applying one coat of aluminum paint over the APP modified membrance @ 0.11Kg/sqm.
5M&L for 4mm thick Non asbestos fibre 600 x 600 mm cement building boards fixed or laid/ inserted to timber/GI/Aluminium framework with nails as in ceiling,including dismantling wall and ceilling boards of any description including cover fillets complete all as specified and directed.
6M&L for Anodised aluminium snap grid frame work for false ceiling complete all as specified and as directed.
7M&L for Hangers 6 mm dia. G.I. (upto 1200mm length) adjusting level fixed to roof slabs by means of ceilling cleats made out of G.I. flat 40 x 3 mm size 60mm long and expansion hold fasteners 12.5mm dia. 40mm long complete all as specified and as directed.
8Demolition of Precast cement concrete block walling in any position, complete all as specified and directed.
9M&L Precast PCC (1:3:6) type C1 (using 20mm graded agg) solid block masonry exc 10cm in width or girth and setting CM (1:6) complete all as specified and directed.
10Taking down cement plaster in cement or cement lime mortar on brick or stone walls etc. including raking out joints, hacking for key, scrubbing down with water etc, Including removal of debries out side MD land all specified and directed.
11M&L for rendering 10 mm thick on concrete surface in cement mortar (1:6) as backing coat and 5 mm th in CM 1:4 using finishing the surface even and smooth without using extra cement, including mixing only liquid water proofing compound as per manufacturer instruction complete all as specified and as directed on External surface complete all as specified and directed. Note:- WPC will be measured & Paid separately
12M&L for 10mm thick plaster in cm (1:6) on fair faces of brick or concrete surfaces including finishing even & smooth without using extra cement complete all as specified and as directed.
13M&L for rendering 05 mm thick in CM 1:3 on ceiling surfaces of cement concrete and finished the surface even and smooth without using extra cement complete all as specified & directed.
14Supply only for water proofing compound complete all as specified and directed.
15M&L for complete removal of existing treatment from for applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over complete all as specified and directed
16M&L for preparation of new plaster external surface of wall and applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over complete all as specified and directed.
17Complete removal existing treatment and applying two coats of White wash complete all as specified and as directed.
18Complete removal existing treatment and applying 1mm thick of Birla white wall care putty to achieve smooth surfaces and applying two coats of Oil Bound Distemper of approved shade/tint over a coat of compatiable priming paint complete all as specified and as directed.
19M&L for preparation of new plastered/concrete surfaces of walls and applying three coats of White wash complete all as specified.
20M&L for preparation of new plastered/concrete surfaces of walls, providing 1 mm thick of Birla white wall care putty to achieve smooth surfaces and applying two coats of Oil Bound Distemper of approved shade/tint over a coat of compatiable priming paint complete all as specified.
21M&L for preparation of old painted wooden surfaces of any description over 10 cm width or girth and applying one coat of synthetic enamel paint complete all as specified and directed.
22M&L for preparation of old painted of steel or iron surfaces of any description not otherwise described over 10cm width or girth and applying one coat of Synthetic enamel paint complete all as specified.
23Demolition of plain cement concrete (unreinforced) in ground floors and pavings nexc 15 cm thickness (below or above ground level) complete all as specified and as directed.
24M&L for Hard core, broken stone /boulders to gauge n exc 63 mm size , deposited , spread and levelled in layers n exc 15cm thick, watered and rammed to a true surface complete all as specified and directed.
25M&L for 75 mm thick PCC 1:3:6 type C2 (using 40mm graded agg) as in plinth protection/path incl finishing even & smooth with using extra cement in, complete all as specified and directed.
26M&L for PCC 1:3:6 type C2 (using 20mm graded aggregate) as in surface channels and drains complete all as specified and as directed.
27Extra for forming fair finished drain or channel 30cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred/stopped ends etc complete all as specified and as directed.
28Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and as directed.
29M&L for 25mm thick PCC 1:2:4 type B-0 (12.5 mm graded aggregate) as in levelling coarse of tile flooring etc complete all as specified and as directed.
30M&L Non-skid ceramic colour tiles 7 to 8 mm thick , (square/rectangular), area of each tiles exceeding 0.06 Sqm but not exceeding 0.11 Sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match with the colour of the tiles over and including 15 mm thick screed bed in cement sand mortar 1:4 complete all as specified and as directed.
31M&L Glazed ceramic colour tiles of size 300 x 450 x 7mm thick in vertical wall etc set and jointed with neat cement slurry and pointed in white or colour cement to match with the colour of tile over and including 10 mm thick backing course in cement sand mortar 1:4 complete as specified and directed.
32Demolition of stone slabs and granite laid, bedded and pointed in any mortar of any description or thickness in floors, aprons cills or plateform etc all as specified and directed.
33M&L for green Marble work 18 to 20mm thick (table rubbed and polished) in steps, jambs, pillars, windowcills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with marble shade complete all as specified and as directed.
34M&L for rounding to edges of stone slabs one edge, such as in steps cooking plateform, and other similar situation complete all as specified and as directed.
35M&L for Machine cut kota stone slab flooring 20-25 mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing and 20 mm thick screed bed in CM 1:3 including roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust etc complete all as specified and as directed.
36M&L for Kota stone slab 20-25 mm thick in riser of steps, skirting, dado and pillar laid over cement screed and jointed with 10 mm thick baking course in CM 1:4 including roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust etc complete all as specified and as directed.
37M&L Chequered cement concrete tiles 20cm x 20cm x 25mm thick, set jointed and pointed in neat cement slurry in floor with grey cement and pigment over 15mm thick screed bed in cement mortar 1:4 including roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust etc
38M&L for Pre cast RCC 1:2:4 type B1 using 20 mm graded stone aggregates as in cover slab for soakage well / manhole and similar works supported on walls set in cement mortar 1:6 complete all as specified and as directed.Note:- Reinforcement steel will be measured & paid sepratly.
39M&L for mild steel TMT bars 10mm dia and over, cut to length, bent to shape required including bending, and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips complete all as specified and as directed.
40Demolition of plain cement concrete (unreinforced) Concrete of any description and in any position not otherwise specifically provided for complete all as specified and as directed.
41M&L for PCC (1:5:10) type E2 (using 40mm graded agg) as in sub base of WC complete all as specified and as directed..
42M&L for Rendering 10 mm thick on brick work or concrete surfaces in cement mortar 1: 4 mixed with WPC and finishing the surface even and smooth without using extra cement complete all as specified and directed.(NOTE: Supply only WPC shall be measured and paid separately)
43M&L for applying two coats of Acrylic polymer modified cementitious waterproofing coating Sika top ® - 107 Seal IN or equivalent in FOSROC on plastered surfaces as per manufacturer instructions complete all as specified and as directed.
44Demolition cement Concrete (RCC) of any description and in any position not otherwise specifically provided for complete all as specified.
45S&F 1000 litres capacity double layer, rotational molded, polythene (white colour), tripple layer water storage tank, ISI Marked (Cylindrical vertical with closed top),colour white , hoisted and fixed on roof in position, including all fitting such as connection pieces with GI tank nipple for inlet, outlet, washout and overflow etc and including dismantling complete all as specified and as directed.
46S&F in repair for 20mm dia Ball cock valves high pressure of PTMT with epoxy coated Aluminium rod & highdensity plastic ball screwed for iron pipe and fixed. (Minimum weight 2 0 m m - 2 1 0 g ms) complete all as specified and directed.
47Taking down GI tubing 15mm dia and connection including removable to store complete all as specified and directed.
48Supply and fix 15 mm bore galvanised steel water tubing, medium grade including necessary fittings such as GI bends, tee, union etc fixed on wall / floor complete and connecting to water supply pipe line all as specified.
49Refixing only 15mm tubes any grade, to walls and ceilings or laying in floors complete all as specified and directed.
50Taking down GI tubing 20mm dia and connection including removable to store complete all as specified and directed.
51Supply and fix 20 mm bore galvanised steel water tubing, medium grade including necessary fittings such as GI bends, tee, union etc fixed on wall / floor complete and connecting to water supply pipe line complete all as specified and as directed.
52Refixing only 20mm tubes any grade, to walls and ceilings or laying in floors complete all as specified and directed.
53M&L for Cutting chases, of girth not exceeding 10 cm for concealed water tubing or concealed conduit wiring, etc. in stone / brick masonry wall built in cement mortar and making good, disturbed surface in Cement mortar 1:3 complete all as specified and as directed.
54S&F in repair 15mm bore stop cock cast copper alloy, fancy type, chromium plated, screwed down high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for union and fixed complete all as specified and directed. .
55S&F in repair 15 mm bore CP fancy type bib tap long body cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule complete all as specified and directed.
56S&F Health faucet (ABS Body) mild steel chromium plated suitable for 15 mm dia pipe with 1.25 metre long flexible tube and ABS wall hook including making connections and fixed in position complete in all respect as specified.
57S&F in repair brass chromium plated tubular towel rail 600mm long between the flanges and 20mm dia complete all as specified and directed.
58S&F in repair 600mmx450mm bevelled edge mirror of selected quality glass, mounted on 6mm thick AC building board or commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers, complete all as specified and as directed.
59S&F in repair for PVC connections 15mm size with PTMT nuts of length 450mm complete all as specified and directed.
60S&F as in repairs.Vitreous China wash down water down water closet pan (pedestal pattern), white (excluding fixing bolts, flushing cistern and flush pipe) including Plastic water closet seat, black, closed pattern with flat bottom, and cover and mild steel chromium plated or aluminised hinging device complete all as specified and as directed.
61S&F in repairs Vitreous China bowl urinal flat back, size of 465 x 355 x 265 mm white (minimum), complete including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement; fixing automatic flushing cistern with brackets, flush pipe, grating and Union for discharge pipe. with grating and union for discharge pipe complete all as specified and as directed.
62S&F in repair PVC (Plastic polymer Cistern) valve less, Syphonic action type, flushing cistern of capacity 10 litres, low level, white with inlet, ball valve, manually operated with one PVC ball valve horizontal plunger type including provision of 32mm PVC flush pipe of required length and making connections complete all as specified and as directed.
63S&F in repairs Vitreous china WHB, white, flat back, of size 550 x 400 mm including brackets, waste coupling 32mm, and waste Pipe, 32mm incl pedastal complete all as specified and directed.
64S&F in repair pillar tap 15 mm, chromium plated, fancy type complete all as specified and directed.
65S&F in repair PVC (SWR) pipes 110 mm dia single socketed in any length with rubber ring joints fixed to walls/ floor complete including clamps for securing pipe complete all as specified and directed.
66S&F in repair PVC (SWR) pipes 75 mm dia single socketed in any length with rubber ring joints fixed to walls/ floor complete including clamps for securing pipe complete all as specified and directed.
67S&F in repair PVC (SWR) vent cowl 110 mm dia complete all as specified and as directed.
68S&F in repairs PVC (SWR) bend with access door of 110mm bore complete all as specified.
69S&F in repairs PVC (SWR) bend with access door of 75mm bore complete all as specified.
70S&F in repair PVC (SWR) 110mm dia in junction single, (Single T) equal or unequal complete all as specified and as directed.
71S&F in repair PVC (SWR) 75mm dia in junction single, (Single T) equal or unequal complete all as specified and as directed.
72S&F in repair 75mm dia of outlet PVC (SWR) floor trap, plain with grating including jointing with solvent cement complete all as specofied and directed.
73Taking down chowkhats or frame with shutter without taking off shutter from the frame exc 1.50 sqm but not exc 4 sqm each & removing from site complete all as specified and directed.
74Taking down chowkhats or frame with shutter without taking off shutter from the frame not exc 1.50 sqm & removing from site complete all as specified and directed.
75Resecuring or easing & adjusting without taking down the shutter of any description exc 1 Sqm and n.exc 2 Sqm in same opening complete all as specified and directed.
76S&F MS flat iron such as small articles for hold fast and similar work complete all as specified and as directed.
77M&L PCC (1:2:4) type B1 (20mm graded Aggregate) for fixing hold fast complete all as specified and as directed.
78Supply and fixing 2nd class HW plain solid straight chowkhats/frame wrought framed rebated on the solid, rounded or chamfered put together with glue pinned at joints complete all as specified and directed.
79Supply and fixing 2nd class HW 35mm thick Glazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc. divided into squares (without sash bars ), edges of framing plain, chamfered or rounded. fitted with cut and mitred beads for securing glass, etc.; sizes of me-mbers of shutters as specified in SSR Part I, Section 8, clause 8.24 (a); supplied and fitted to chowkats complete all as specified and as directed.
80Supply and fixing 2nd class HW 35mm thick plain framed panelled shutters (any number of panels), with panel of timber flats on both sides or of veneered particle board medium density, wood particle board with commercial face veneers; supplied and fitted to chowkats complete all as specified and as directed.
81Supply and fixing solid PVC door frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with MS square tube complete all as specified and as directed.
82S&F Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, suppling & fixing in the frame at site as per specification & drawing complete all as specified and as directed.
83S&F powder coated (min powder coating 50 micron) anodised aluminium frame for doors, windows , ventilators plain or sliding type with one or more rebates including joining cleat for fixing etc complete all as specified and as directed
84S&F powder coated(powder coating min 50 micron) anodised window and ventilator shutters side hung/sliding type without sash , aluminium section weighing 0.55 kg/m including necessary joining cleats,glazing clips, rubber neoprene packing , anodised aluminium snap beading screws ,anodised aluminium fittings such as peg stays 150 mm long(1 no) hinges type B-21 100 mm long (2 no) suitable handle (1 no ) complete all as specified and as directed.
85S&F Anodised aluminium grill (anodised transparent or dyed to required shade according to IS: 1868 with minimum anodic coating of grade AC 15) of approved design/pattern, with approved standard section and fixed to the existing window frame with C.P. brass/ stainless steel screws @ 200 mm centre to centre, including cutting the grill to proper opening size for fixing and operation of handles and fixing approved anodised aluminium standard section around the opening, complete all as specified and as directed.
86M&L for preparation of new wooden surfaces of any description over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and directed.
87Supply and fixing 100mm size butt hinges cold rolled medium weight, ISI marked complete all as specified and directed.
88Supply and fixing 200mm size MS barrel tower bolt stone enamelled black with bright bolt ISI marked complete all as specified and directed.
89Supply and fixing 150mm size MS pressed handle oval type stove enameled block complete all as specified and directed.
90Supply and fixing 250mm long MS sliding door bolt, plate type, stove enameled black with bright bolt not less than 12mm dia with and including a min of siz bolt & nuts four on bolt & two on staple,ISI marked, complete all as specified and directed.
91S&F 140mm long Floor door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring, fixed in floor complete all as specified and as directed.
92S&F 300mm long mild steel ordinary rat tail rod pattern springs including roller and roller plate complete all as specified and as directed.
93S&F Galvanised mild steel wire cloth, 0.63mm nominal dia of wire and average width of aperture 1.40mm and fixed with tinned tacks, or galvanised wire staples comlete all as specified and as directed.
94S&F in repairs Galvanised mild steel wire cloth, 0.63mm nominal dia of wire and average width of aperture 1.40mm and fixed with tinned tacks, or galvanised wire staples comlete all as specified and as directed.
95M&L for 4.80 mm thick sheet glass quality and glazing fixed to aluminium frame exc 0.50 sqm complete all as specified and as directed.
96M&L for 4.80 mm thick frosted sheet glass quality and glazing fixed to aluminium frame exc 0.50 sqm complete all as specified and as directed.
97Forming jambs, etc. to openings CM 1:6 (to foregoing item), including cutting, toothing and properly bonding into old work, also facing, jointing and pointing to match existing work, complete all as specified and as directed.
98Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and dircted.
99S&F for MS frame work such as grills grating etc, with ends of bar shouldered and or riveled, or forged into spickes framed quared bars and similar work complete all as specified and as directed.
100S& F Stairs (framed) including stringers, treades, landing, balusters, hand rails etc. inclug cleats, (Fe-410) brackets, etc.complete all as specified and as directed.
101M&L for Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc complete all as specified and as directed.
102M&L for preparation of new steel surface and applying of two coat of synthetic enamel paint over a one coat of red oxide exc 10cm width or girth complete all as specified and as directed.
103S&F in repair stainless steel decorative pattern holder/end brackets suitable for drapery rod of 25 mm dia complete all as specified and as directed.
104S&F in repair stainless steel decorative pattern end support suitable for drapery rod of 25 mm dia complete all as specified and as directed.
105S&F in repair 25 mm dia stainless steel drapery rod not less than 1mm thick cut to size and fixed in position, including Standard screw complete all as specified and as directed.
106Taking down carefully aluminium/copper conductor point wiring (light,fan,socket or power) complete including fittings such as switches,ceiling roses, pendants, regulators ,sockets LED battens etc. and removing (except those to be reused shall be kept in safe custody at the site ) and making good disturbed surfaces of walls, floors etc.to match with the existing complete all as specified and as directed.
107Material and labour concealed point wiring for one light/fan/exhaust fan point controlled by one, one way switch using 1.5 sqmm nominal cross sectional area multistranded copper conductor ,PVC insulated unsheathed FRLSH cables in and including suitable size PVC conduit and fittings of medium grade, including pressed steel / PVC terminal switch boxes fitted with chromium plated brass screws & washers and 1.5 sqmm nominal cross sectional area multistranded copper conductor FRLSH PVC insulated unsheathed earth wire and connecting to earth dolly and brass screws, washers etc complete all as specified and directed.
108All as per item No.107 above but One 3 pin 5 Amps socket out let points on independent board complete all as specified and as directed.
109All as per item No.107 above but 5 Amp socket on same board with other switches complete all as specified and as directed.
110Material and labour point wiring for power point controlled by one, one way switch using 2.5 sqmm nominal cross sectional area multistranded copper conductor ,PVC insulated unsheathed FR cables in and including 20 mm width or higher size PVCconduit and fittings of medium grade, including including pressed steel / PVC terminal switch boxes, 3 mm thick bakelite sheet top cover (ISI Marked) fitted with chromium plated brass screws & washers and 2.5 sqmm nominal cross sectioanl area multistranded copper conductor FR PVC insulated unsheathed earth wire and connecting to earth dolly and brass screws, washers etc. complete all as specified and directed.
111Supply and fixing submain wiring for DBs/ Power Point, two single core ,4 sqmm nominal cross sectional area multistranded copper conductor FR cable, PVC insulated unsheathed 1100 Volts grade drawing in and including suitable size PVC conduit (ISI marked) including 4 sqmm nominal cross sectional area multistranded copper conductor FR cable, PVC insulated unsheathed 1100 Volts grade earth wire complete all as specified and as directed.
112Supply and fixing submain wiring for DBs/ Power Point, two single core ,6 sqmm nominal cross sectional area multistranded copper conductor FR cable, PVC insulated unsheathed 1100 Volts grade drawing in and Including suitable size PVC conduit (ISI marked) including 6 sqmm nominal cross sectional area multistranded copper conductor FR cable, PVC insulated unsheathed 1100 Volts grade earth wire complete all as specified and as directed.
113Supply and fix socket outlets 2 in 1, 3 pin, 5/6 Amps flush type230/240 V complete all as specified and as directed. (For Same Board only) complete all as specified and as directed.
114Supply and fix Switch socket Combination 16A, 6 pin, 3 module 230 V complete all as specified and as directed.
115Supply and fix switch socket combination 2 in 1 multipurpose 5 pin , (6 Amps ) flush type controlled by one switchcomplete all as specified and as directed.
116Supply and fix switch piano flush type, single pole , 5/6 Amps, one way complete all as specified and as directed.
117Supply & fix ceiling rose surface bakelite 65 mm x 50 mm two to three terminal suitable for 230 Volts AC 6 Amps complete all as specified and as directed.
118Supply and fix 18 W LED light fitting wall mounted batten 4'ft , extruded aluminium housing, enivromental friendly, heat sink provided for efficent heat dissipation and integrated electronic driver for 20 watt,6000K including necessary connection complete all as specified and directed.
119Re fixing serviceable LED batten obtained from Item No.1 complete all as specified and as directed.
120Supply and fixing in repair LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and as directed.
121Supply and fix Vertical distribution board double door MCB TPN 4 way with IP 43 multiphase outgoing suitable for mounting 63-100 Amps MCCB as incomer with Bus bars, Neutral links complete with all accessories complete all as specified and as directed.
122Supply and fix epoxy powder coated sheet metal enclosure for DBs, double door, Single pole and neutral 240 V, 12 ways with mounting fitted with bus bar, DIN channel , neutral link and incoming contact complete all as specified and as directed.
123Supply and fix MCB SP, 6 to 32 Amps, 'C' series 10kA, 240 Voltsand to be housed in DBs including necessry connection complete all as specified and directed.
124Supply and fix MCB SPN 40 - 63 Amps, 'C' series 10kA, 240 Volts and to be housed in DBs complete including necessry connection complete all as specified and as directed.
125Supply and fix MCCB 40 - 100 Amps, breaking capacity 16kA, 240 Volts and to be housed in DBs complete including necessry connection complete all as specified and as directed.
126Taking down and refixing exhaust fan,of any size and description in serviceable condition with all accessories complete all as specified and as directed.
127Taking down and re- fixing Water heater storage type, electric,of any capacity including all accessories complete all as specified and as directed.
128Material and labour for earthing complete with galvanised mild steel earth plate electrode 600x600x6.0mm thick, burried directly in ground to a depth not less than 2.25 metres deep below ground level with top edge of earth plate not less than 1.5 metre below normal ground level surrounded with adequate quantity of charcoal dust mixed with salt to a packed thickness of 15 cm all around the plate, using GI wire 4mm as earth electrode bolted or rivetted to earth plate at one end and connected to equipments at another end, GI earth wire encased in and including 40 mm dia GI 'light grade' pipe from upper end of earth plate upto equipments,20 dia bore GI pipe 'light grade' as water pipe from earth chamber to upper edge of earth plate, Test point , GI funnel with wire mesh fixed on water pipe and PCC 1:2:4 type B-1 (using 20mm graded stone aggregate) as in pit chamber and RCC pit cover 50mm thick precast RCC 1:2:4 type B-1, duly reinforced with MS round bars 6mm dia @ 100 c/c both ways with 10mm dia MS round bar as in lifting handles, excavation, earth work including laying the GI pipe concealed in floor/wall all as described in electric plate No 3 of SSR Part I complete all as specified and directed and testing on completion complete all as specified and as directed.
129Earth work in Ordinary rock excavation by mechanical means (Hydraulic excavator) means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5m, complete all as specified and as directed.
130Ref item No. 129 for each additional 1.5 m or part thereof in depth beyond the first 1.5 m complete all as specified and as directed.
131Returning, filling in including spreading, leveling, watering and well ramming in layers n.exc 25 cm thick in soft/loose soil complete all as specified and directed.
132Removing of surplus excavated material n.exc 50 m and depositing where directed at a level n.exc 1.5 m above the starting point in soft soil complete all as specified and directed.
133M&L for PCC (1:4:8) type D2 using 40mm graded stone aggregate as in foundation complete all as specified and as directed.
134M&L for RCC types A1 1:1.5:3 (20mm graded aggregate) as in Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and as directed.
135M&L for Reinforced cement concrete Type-B1, 1;2:4 (20mm graded stone aggregate) in Foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete complete all as specified and as directed.
136M&L for Reinforceed cement concrete Type B1, 1:2:4 (20mm graded stone aggregate) Beams, cantilevers, bressummers, lintels over 1.5m span complete all as specified and as directed.
137M&L for Reinforced cement concrete, Type-B1, 1:2:4 (20mm graded stone aggregate) Columns, pillars, piers, posts and struts complete all as specified and as directed.
138Form work to soffits of suspended slab such as roof slabs, floor slabs landing and similar work not exc. 200mm thick(Horizontal or Sloping) complete all as specified and as directed.
139Formwork to sides of concrete of rough finished on flat surfaces in foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter complete all as specified and as directed.
140Formwork in rough finished surfaces of of rectangular, square or polygonal sides of pillars, posts, struts, piers, columns and stanchions complete all as specified and as directed.
141Formwork to sides and soffits in rough finished flat surfaces of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including sup- ports, overhangs, etc. also splays between floors and beams, etc complete all as specified and as directed.
142M&L for Brickwork with sub class ‘B’ bricks in one brick thick honey comb walling, built in CM 1:3 complete all as specified and as directed.
143M&L for Loose filling with broken bricks of gauge 80 to 150 mm in soakage pits, soakage wells complete all as specified and as directed.
144M&L for Pre cast RCC 1:2:4 type B1 using 20 mm graded stone aggregates as in cover slab for soakage well / manhole and similar works supported on walls set in cement mortar 1:6 complete all as specified and as directed.Note:- Reinforcement steel will be measured & paid sepratly.
145M&L for TMT bars 10 mm dia cut to length bent to shape etc as required and binding with and including MS wire (annealed) not les than 0.9 mm dia as in reinforcement complete all as specified and as directed.
146M &L for 75mm thick PCC (1:3:6) type B2 as in flooring of septic tank, manhole etc with 40mm graded aggregae finishing cement concrete surface even and smooth using extrra cment complete all as specified and directed.
147M&L for PCC (1:2:4) type B0 as in benching & coping with 12.50mm graded aggregate incl necessary form work moulds all as specified and as directed.
148M&L Precast PCC (1:3:6) type C1 (using 20mm graded agg) solid block masonry exc 10cm in width or girth and setting CM (1:6) including demolition of Precast cement concrete block walling in any position and Including removal of debries out side MoD land complete all as specified and directed.
149M&L for rendering 10 mm thick in cement mortar (1:4) and finish even and fair without using extra cement including taking down cement plaster in cement or cement lime mortar on brick or stone walls etc. including raking out joints, hacking for key, scrubbing down with water etc, Including removal of debries out side MD land all specified and directed.
150M&L for preparation of old decorated plastered surfaces of walls including cornices, plasters etc and applying two coat of white wash complete all as specified and directed
151S&F in repair Salt-glazed stoneware gully traps, square or round mouthed, tvpe of size 150 x 100 mm complete all as specified & directed.
152M&L for salt glazed stone ware drain pipes 200 mm bore grade ‘A’ laid in trenches and jointed in cement mortar (1:1) including cement concrete (1:4:8) type D-2 (using 40 mm grade stone aggrete) as in concrete bed to drain pipes, packing under & haunching against the sides of pipes after they are laid & tested including demolition and breaking up old drain pipes 200 mm dia (salt glazed stone ware, AC or reinforced concrete) pipe set in cement mortar and removing from site of work to a distance n exc 50mtrcomplete all as specified and as directed.
153M&L for salt glazed stone ware drain pipes 150 mm bore grade ‘A’ laid in trenches and jointed in cement mortar (1:1) including cement concrete (1:4:8) type D-2 (using 40 mm grade stone aggrete) as in concrete bed to drain pipes, packing under & haunching against the sides of pipes after they are laid & tested including demolition and breaking up old drain pipes 150 mm dia (salt glazed stone ware, AC or reinforced concrete) pipe set in cement mortar and removing from site of work to a distance n exc 50mtr complete all as specified and as directed.
154Taking out and removing sludge water/waste materials/foreign materials from septic tank of any number of user and burring the entire sludge under ground in the pit of suitable size and covering the pit with earth or earth mixed rubbish and removing surplus soil to a distance n.exc 50 m including necessary earth work in pit complete all as specified and as directed.
155Cleaning of manholes with spades or bucket taking out sludge from manhole and disposed off aside by putting earth on it. Again use water with bucket and put in manhole to clear the sludge and ensure the sludge is drain out completely. The depth of manhole n.exc 1 mtr each complete all as specified and as directed. NOTE FOR ALL ITEMSIn case in BOQ any item found repeated and contractor quotes different rate for the same, the rate quoted on lesser side shall only be applicable for payment and no claim whatsoever on this account shall be entertained by the Department. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 58048575
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 46.68 Lakhs
LAST DATE 04-11-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Addn/Altn To Bldg No. A-56 (Or Single Living Accn) Alongwith Replacement Of Tiles At Signal Unit, Happy Valley And Provn Of 02 X Septic Tank And Soak Well For Sentry Post No. 1 And Post No. 2 At Signal Unit Happy Valley Under Ge Shillong
Basic Detail
Tender No GE/SHL/TOKEN-90 OF 2026-27
Bidding Type Tender
Location
City East Khasi Hills
State Meghalaya
Key Dates
Publish Date 14 Oct 2026
Submission Date 04 Nov 2026
Open Date 05 Nov 2026
Finance
Tender Value 46.68 Lakhs
Tender Fee 500
EMD 93360
Exemption Available
Document List
BOQ_890441.xls
ec9e1057-0532-4cbf-9ae1-5f9c4faf4b79.html
TENDERDOCU90.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Oct 14, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Nov 04, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 18 days
Nov 05, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 19 days

Tender Documents

Download All (ZIP) ↓
xls

BOQ_890441.xls

html

ec9e1057-0532-4cbf-9ae1-5f9c4faf4b79.html

pdf

TENDERDOCU90.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender