Tender For Comprehensive B/R Repair To Include Sunken Floor,Repairs To Roof, Ceiling, Day To Day Maintenance And Other Connected Works At Site A2 Of Naval Base Area Karwar.
Tender Value
49.60 Lakhs
Estimated cost
Bid Submission
04 Nov 2026
7 days left
EMD
99200
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Uttara Kannada → Karnataka
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Comprehensive B/R Repair To Include Sunken Floor,Repairs To Roof, Ceiling, Day To Day Maintenance And Other Connected Works At Site A2 Of Naval Base Area Karwar.
BOQ
| Sl. No. | Item Description |
| 1 | Demolition of cement concrete of any description in sunken floor or in any position as specified and directed. . |
| 2 | Treatment of sunken floor slab comprises of the following specifications and all as specified:-(i) M&L for cleaning the sunken/ lowered portion of RCC slab surface (including vertical total depth plus skirting height) of floors by wire brush, chisel out any mortar sticking to the surface and brooming completely. 40mm thick average PCC 1:2:4 type B-0 using 12.5mm graded stone aggregate as in padding concrete to achieve proper slope (ii) Rendering of uneven surfaces with 6mm thick CM 1:4 mixed with integral water proofing compound at the rate as per manufacturer's instructions. Fill it with water and check dampness and seepage. Where dampness/seepage is noticed, nozzles shall be fixed and grouting to be carried out (WPC shall be measured and paid separately)(iii) All junctions points of side wall where CI/GI pipes are passing through shall be sealed with epoxy putty.(iv) After drying putty, wash the slab and sides of sunken portion with water and make it clear and clean. |
| 3 | (v) M&L for applying two coats of polymer modified cementious water proof coating as per manufacturer's instruction to bottom and vertical sides up to finished floor level +100mm height. The thickness of two layer shall be 1mm. When the second layer is still sticky,, coarse sand spray shall be carried for the vertical and bottom surface of the sunken portion all as specified and directed. (This item shall be measured and paid separately).(vi) Plaster the bottom and sides up to bottom of the skirting with minimum 20mm thick CM 1:4 mixed with integral water proofing compound as per manufacturer's specification including rounding of corners and junctions sloping towards spout. (WPC shall be measured & paid separately ) (vii) All pipes laid in sunken portion shall be covered with 50mm thick PCC 1:3:6, all round after painting with anticorrosive paint (Black paint shall be paid separately)Note:- Test the water proofed area (ponding test) by filling water for at least 72 hours and tested for leakage seepage and to the entire satisfaction of GE. Test shall be done in presence of reps of PMG and record for each sunken slab shall be maintained. The treatment shall be carried out by authorised applicators of chemicals. Cost of testing shall be deemed to be included in the rate quoted above. |
| 4 | M&L for applying two coats of polymer modified cementious water proof coating as per manufacturer's instruction to bottom and vertical sides up to finished floor level +100mm height. The thickness of two layers shall be 1mm. When the second layer is still sticky, coarse sand spray shall be carried for the vertical and bottom surface of the sunken portion all as specified and directed. |
| 5 | Supply only Integral Water proofing compound complete all as specified and directed. |
| 6 | M&L for PCC 1:5:10 type E-2 using 40mm graded stone aggregate as in sunken floor of toilet complete all as specified and as directed. |
| 7 | Dismantling of single layer Mangalore pattern or similar tiles in roofing all as specified and directed. |
| 8 | M&L for roof tiles, Mangalore pattern class 'AA', interlocking at side joints, laid dry complete all as specified and directed. |
| 9 | All as per item No. 07 above but except tiles |
| 10 | M&L for Ridge or hip tiles to suit Mangalore pattern or roofing tiles, bedded and jointed in cement mortar 1:6 complete all as specified and directed. |
| 11 | Demolition of cement cocrete of any discription and any position all as specified and directed. |
| 12 | M&L for cement concrete type B0 (1:2:4) using 12.5 mm graded aggregate, as in roof kerbs/paddings or mud stops or bedding for tiles, etc., chamfered at edges, complete all as specified and directed. |
| 13 | Dismantling/taking out existing textile covering including frames (if any) or hessian base felt or any other existing waterproofing treatment from roof, including cement plaster and exposing the top surface of RCC slab, including removing the dismantled debris to a distance exceeding 200 m but not exceeding 250 m, complete all as specified and directed. |
| 14 | M & L for providing 15 mm thick rendering over roof slab in cement mortar (1:4), mixed with waterproofing compound as per manufacturer's instructions, finished to an even and smooth surface without using extra cement, complete all as specified and directed. Note: Water proofing compound shall be measured and paid separately. |
| 15 | M&L Providing and Installing Asian Make SmartCare TPO Membrane Reinforced Membrane is a high performance, heat weldable, scrim reinforced thermoplastic polyolefin (TPO) sheet manufactured & supplied in thickness of 1.5mm as per UNI EN 1849-2, designed for waterproofing and heat shielding roofs of new and existing buildings. The membrane shall have elongation at break >15% as per UNI EN 12311-2 , Hydrostatic Pressure Resistance (6 hrs @5 bar) as per UNI EN 1928 met B ,Tearing Strength (N) >300 as per UNI EN 12310-2, Puncture resistance (mm) of >700 as per DIN 16726-5.12 , Tensile Strength (N/5 cm) is >1100 as per UNI EN 12311-2, the joint of membrane should welded with double seam welding machine and detailing of membrane can be done through hand applied welding tools. The membrane shall be terminated at min height of 300mm above FFL in the vertical areas using termination bar and mechanical fasteners and PU sealant, complete as per manufacturer specifications and product data sheets all as specified and directed. |
| 16 | Dismantling of Galvalume aluminium zinc-coated GI-based plain or corrugated steel sheets of any thickness in roofing, complete all as specified and directed. |
| 17 | S&F pre-painted Galvalume aluminium zinc-coated GI-based corrugated steel sheets, 0.50 mm thick, of any colour, having tensile strength of 550 MPa, as in roof covering/cladding to walls, fixed with self-tapping screws, complete all as specified and directed. |
| 18 | S&F pre-painted Galvalume aluminium zinc-coated GI-based plain steel sheets, 0.50 mm thick, of any colour, having tensile strength of 550 MPa, as in roof covering/cladding to walls, fixed with self-tapping screws, complete all as specified and directed. |
| 19 | Dismantling of wall and ceiling boards (fibre, pulp, insulation) or insulation boards/slabs/blankets of any description and thickness, including frame/grid of any description, complete all as specified and directed. |
| 20 | M&L for anodised aluminium snap grid (minimum 15 microns anodisation) of size 605 × 605 mm with anodised aluminium angle of size 40 mm × 25 mm × 2 mm thick, weighing 0.36 kg per running metre, and anodised aluminium main and cross tees of size 36.50 × 23.50 × 1.50 mm thick weighing 0.254 kg per running metre and 23.50 × 23.50 × 1.50 mm thick weighing 0.202 kg per running metre respectively, for false ceiling, complete all as specified and directed. |
| 21 | S&F hangers 6 mm dia GI (upto 1200 mm length), adjusting level, fixed to roof slabs by means of ceiling cleats made out of GI flat 40 × 3 mm, 60 mm long, and expansion hold fasteners 12.5 mm dia × 40 mm long, suitable for snap grid 605 × 605 mm, complete all as specified and directed. |
| 22 | M&L for PVC insulation panels of 10 mm thickness with EPS bonded to 1 mm thick plain PVC sheet, suitably placed in false ceiling grid made of aluminium/GI/MS, fixed with screws on snap grid, complete all as per manufacturer’s instructions and as specified and directed. |
| 23 | M&L for perforated particle board/tiles for insulation and acoustic purposes of size 600 × 600 mm, 12 mm thick, fixed with staples on snap grid in ceiling, complete all as specified and directed. |
| 24 | Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and removing debris as directed by Engineer-in-Charge, complete all as specified and directed. |
| 25 | Demolition of stone slabs and tiles of any description or thickness in floors, aprons, etc., laid, bedded and pointed in any mortar, complete all as specified and directed. |
| 26 | Taking up or down GI tubing and connections, 15 mm bore, including cleaning or removal to store, complete all as specified and directed. |
| 27 | Taking up or down GI tubing and connections, 20 mm bore, including cleaning or removal to store, complete all as specified and directed. |
| 28 | Dismantling of PVC/RCC water storage tank of capacity exceeding 250 litres but not exceeding 500 litres, including removal of debris outside MoD land, complete all as specified and directed. |
| 29 | Dismantling of PVC/RCC water storage tank of capacity exceeding 500 litres but not exceeding 1000 litres, including removal of debris outside MoD land, complete all as specified and directed. |
| 30 | M&L for coloured glazed ceramic tiles (1st quality) of size 300 × 200 × 7–8 mm or 300 × 450 × 7–8 mm thick on vertical surfaces such as skirting, dado and risers to steps, including 10 mm thick cement plaster in CM (1:3), set and jointed in neat cement slurry and pointed in white or coloured cement to match, complete all as specified and directed. |
| 31 | M&L for non-skid ceramic coloured tiles (1st quality), 7–8 mm thick (square/rectangular), area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm, as in floors, laid over and including 15 mm thick screed bed in CM (1:4), set and jointed in neat grey cement slurry and pointed in white or coloured cement to match, complete all as specified and directed. |
| 32 | M&L for vitrified ceramic tiles (premium quality), light shade, 8–10 mm thick (square/rectangular), size 600 × 600 mm (area not exceeding 0.36 sqm), laid in floors with neat cement slurry @ 3.0 kg/sqm over and including 15 mm thick screed bed in CM (1:4), including pointing in white cement with pigment to match the shade of tiles, complete all as specified and directed. |
| 33 | M&L for vitrified coloured tiles 600 × 600 × 8–10 mm thick, as in skirting, set and jointed in neat cement slurry and pointed in coloured cement over 10 mm thick rendering in CM (1:3), including taking down existing wall dado/finishes of any description, complete all as specified and directed. |
| 34 | M&L for 20 mm thick granite (any type) work, black colour, table rubbed and polished, in steps, cooking platforms, etc., set in CM (1:4), including pointing in white cement (1:2) with marble dust and pigment to match shade, over and including 20 mm thick backing in CM (1:6), complete all as specified and directed. |
| 35 | M&L for 20 mm thick granite stone slab (any type), machine cut, as in skirting/dado, laid over cement screed, jointed with grey cement slurry and pointed with white cement with pigment to match shade, including cutting and polishing and including 10 mm thick backing coat in CM (1:3), complete all as specified and directed. |
| 36 | M&L for 20 mm thick, machine-cut Kota stone slabs, as in floors, steps, landings, etc., set and jointed in neat cement slurry and pointed in coloured cement to match shade, including cutting and polishing and including 20 mm thick screed bed in CM (1:4), complete all as specified and directed. |
| 37 | M&L for 20 mm thick, machine-cut Kota stone slabs, as in risers of steps, landings, skirting, dado and pillars, set and jointed in neat cement slurry and pointed in coloured cement to match shade, including cutting and polishing and including 20 mm thick screed bed in CM (1:4), complete all as specified and directed. |
| 38 | Taking down cement plaster on brick or concrete surfaces of walls/ceilings, including raking out joints, hacking for key, scrubbing with water, etc., including removal of debris outside MoD land, complete all as specified and directed. Note: Rate includes necessary scaffolding and formwork. |
| 39 | M&L for rendering 15 mm thick on brick or concrete surfaces in CM (1:4), mixed with waterproofing compound as per manufacturer's instructions, complete all as specified and directed. Note: Water proofing compound shall be measured and paid separately. |
| 40 | M&L for rendering 10 mm thick in CM (1:6) on fair faces of concrete surfaces, complete all as specified and directed. |
| 41 | M&L for 5 mm thick rendering on fair faces of brickwork or concrete surfaces in CM (1:3), as in ceilings, complete all as specified and directed. |
| 42 | M&L for preparing newly plastered wall surfaces and applying two coats of oil-bound distemper using mechanical spray (maximum working pressure 3300 PSI) over a coat of primer, including finishing with 3 mm thick wall care putty, complete all as specified and directed. |
| 43 | M&L for preparing newly plastered ceiling surfaces and applying two coats of oil-bound distemper using mechanical spray (maximum working pressure 3300 PSI) over a coat of primer, including finishing with 3 mm thick wall care putty, complete all as specified and directed. |
| 44 | M&L for two coats of exterior weatherproof emulsion paint using mechanical spray (maximum working pressure 3300 PSI) over a coat of primer, including preparation of new plastered wall surfaces, complete all as specified and directed. |
| 45 | S&F unplasticised PVC pipes of pressure rating 10 kgf/cm², fixed complete to walls, ceilings or floors, 15 mm bore, medium grade, ISI marked, including all fittings, complete all as specified and directed. |
| 46 | S&F unplasticised PVC pipes of pressure rating 10 kgf/cm², fixed complete to walls, ceilings or floors, 20 mm bore, medium grade, ISI marked, including all fittings, complete all as specified and directed. |
| 47 | S&F stop/angle valves, cast copper alloy, fancy type, chromium plated, screwed down high pressure with crutch or butterfly handle, screwed both ends for 15 mm bore pipe, complete in repairs all as specified and directed. |
| 48 | S&F bib taps, cast copper alloy, chromium plated, with crutch or butterfly handle, screwed down for 15 mm bore pipe, complete in repairs all as specified and directed. |
| 49 | S&F pillar taps, cast copper alloy, fancy type, chromium plated with capstan heads, screwed down high pressure with long screwed shanks and fly nuts, suitable for 15 mm bore pipe, complete in repairs all as specified and directed. |
| 50 | S&F vitreous china wash-down water closet (pedestal pattern), white, including fixing bolts and connections to existing pipes, complete in repairs all as specified and directed. Note: Rate excludes flush pipe, cistern and seat cover. |
| 51 | S&F Orissa pattern WC, size 580 × 440 mm, white, with integral footrests, excluding flushing system, including P or S trap, fixed complete, in repairs all as specified and directed. |
| 52 | S&F plastic WC seat and cover (closed pattern) with flat bottom, suitable for pedestal/semi-pedestal WCs, with MS chromium plated/aluminised hinges, complete in repairs all as specified and directed. |
| 53 | S&F brass chromium plated health faucet with flexible pipe and required nipple, complete in repairs all as specified and directed. |
| 54 | S&F PVC low-level flushing cistern (valveless, syphonic type), 10 litre capacity, white colour, with inlet ball valve, float, handle and brackets, complete in repairs all as specified and directed. |
| 55 | S&F vitreous china wash basin, white, flat back, size 550 × 400 mm, excluding taps, waste coupling and pipe, but including brackets, complete in repairs all as specified and directed. |
| 56 | S&F vitreous china wash basin, pedestal type, white, size 550 × 400 mm, excluding taps, waste coupling and pipe, but including brackets, complete in repairs all as specified and directed. |
| 57 | S&F vitreous china urinal, half stall type, flat back, white, including grating, union for discharge pipe, chromium plated spreader, connection pipe and downpipe, complete in repairs all as specified and directed. |
| 58 | S&F 32 mm waste coupling, brass chromium plated, for basins/sinks, with long screwed shank, fly nuts and flange, bedded in red lead cement, complete in repairs all as specified and directed. |
| 59 | S&F 32 mm bore PVC waste pipe with fittings for basins/urinals, complete in repairs all as specified and directed. |
| 60 | S&F 80 mm dia brass chromium plated shower rose with swivel joint, fancy type, suitable for 15 mm bore GI pipe, complete in repairs all as specified and directed. |
| 61 | S&F brass chromium plated mixer for hot and cold water, suitable for 15 mm bore pipe, complete in repairs all as specified and directed. |
| 62 | S&F 600 × 450 mm bevelled edge mirror of 5 mm thick glass, mounted on 6 mm thick AC sheet/commercial plywood and fixed with chromium plated brass screws and cup washers, complete in repairs all as specified and directed. |
| 63 | S&F rotational moulded PVC double-layered water storage tank, 500 litre capacity (cylindrical vertical, closed top), ISI marked, hoisted and fixed in position, complete all as specified and directed. |
| 64 | S&F rotational moulded PVC double-layered water storage tank, 1000 litre capacity, ISI marked, hoisted and fixed in position, complete all as specified and directed. |
| 65 | Draining out water, cleaning and removing accumulated sludge/dirt from service tanks up to 500 litres capacity, disinfecting with bleaching powder, and marking “CLEANED ON (DATE)” with white enamel paint (letters 100 mm high), complete all as specified and directed. |
| 66 | All as per Item No. 64.00 above but for tanks exceeding 500 litres and not exceeding 1000 litres capacity. |
| 67 | S&F 25 mm bore brass float valve (high pressure) with polythene float and fly nut, suitable for GI pipe, including necessary fittings, complete in repairs all as specified and directed. |
| 68 | Fixing only rotational moulded PVC double-layered water storage tank, 500 litre capacity, complete all as specified and directed. Note: Material will be issued under Schedule B from B/R store. |
| 69 | Fixing only rotational moulded PVC double-layered water storage tank, 1000 litre capacity, complete all as specified and directed. Note: Material will be issued under Schedule B from B/R store. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Oct 14, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedNov 04, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 7 daysNov 06, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 9 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender