Housing Urban and Rular Development Government Departments Closing in 12 days TDR #58042102

Tender For Repairing And Maintenance Of Civil & Electrical Installation Work In Residential Quarter At Kotshila Rh Under Jhalda-Ii Block, In The District Of Purulia----Electrical Installation Work.

Issued by Government Departments · Purulia, West Bengal
Tender Value
Ref. Documents
Estimated cost
Bid Submission
30 Oct 2026
12 days left
EMD
27219
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Purulia → West Bengal
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Repairing And Maintenance Of Civil & Electrical Installation Work In Residential Quarter At Kotshila Rh Under Jhalda-Ii Block, In The District Of Purulia----Electrical Installation Work.

BOQ

Name of Work:- Repairing and maintenance of Civil & Electrical Installation work in residential Quarter at Kotshila RH under Jhalda-II Block, in the District of Purulia----Electrical Installation Work.
Sl. No. Item Description
1DISTRIBUTION POINTWiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS/HFFR PVC insulated copper conductor single core cable etc as required. [ DSR(E&M)-2025, It. No--1.10 ]Group B [ DSR(E&M)-2025, It. No--1.10.2 ]
2PLUGS & SOCKETSSupplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc. as required. [ DSR (E&M)-2025, Pg.-7, It. No.-1.27]4 Module (125mmX75mm) [ DSR (E&M)-2025, Pg.-7, It. No.-1.27.3]
36 Module (200mmX75mm) [ DSR (E&M)-2025, Pg.- 7, It. No.-1.27.4]
4Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. asrequired. [ DSR (E&M)-2025, Pg.- 7, It. No.-1.24]5/6 A switch [ DSR (E&M)-2025, Pg.-7, It. No.-1.24.1]
515/16 A switch [ DSR (E&M)-2025, Pg.-7, It. No.-1.24.3]
63 pin 5/6 A socket outlet [ DSR (E&M)-2025, Pg.-7, It. No.-1.24.4]
76 pin 15/16 A socket outlet [ DSR (E&M)-2025, Pg.- 7, It. No.-1.24.5]
8Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc as required. [ DSR(E&M)-2025, It. No--1.27 ]12 Module (200mmX150mm) [ DSR(E&M)-2025, It. No--1.27.6 ]
9Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required. [ DSR (E&M)-2025, Pg.- 8, It. No.-1.32]
10Supply & Fixing 240 V, 25 A, Modular type starter (Brand approved by EIC) (Legrand: Myrius/Arterior/L&T/ABB approved by EIC) with 25A Modular switch type DP MCB (CCurve) and 4 Module GI Modular type switch board with 4 Module top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc [PWD(El)-Nov-17, Pg.-E-19, It. No.-17]
11Supply & Fixing 240 V, 25 A, 3 pin Modular type plug socket (Legrand: Myrius/Arterior/L&T/ABB approved by EIC), without plug top and switch with 2 Module GI Modular type switch board with top cover plate flushed in wall and making necy. connections with PVC Cu wire and earth continuity wire etc. [PWD(El)-Nov-17, Pg.-E-17, It. No.-5(a)]
12Supply & Fixing 240 V,25 A, 3 pin Modular type plug top with indicator (Legrand: Myrius/Arterior/L&T/ABB approved by EIC) & necy. Connections. [E-17/5(b)] [PWD(El)-Nov-17, Pg.-E-17, It. No.-5(b)]
13Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. [ DSR (E&M)-2025, Pg.- 7, It. No.-1.26]
14DP M/S, DBS & MCBSupplying and fixing Sheet steel Main Switches on flat iron frame on wall - 240V DP with fuse on L&N 30/32 A , [D-1, It. No.-1(a)]
15Supply & Fixing 240V 32A 3 Nos Cut Out fuse (Kitkat type)& suitable type encloser with accessories & necessary connection etc. Make- (Havelles/L&T) NS
16Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) [ DSR(E&M)-2025, It. No--2.3 ]2 + 8 way, Double door [ DSR(E&M)-2025, It. No--2.3.3 ]
172 + 12 way, Double door [ DSR(E&M)-2025, It. No--2.3.4 ]
18Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. [ DSR(E&M)-2025, It. No--2.10 ]Single pole 5-32A [ DSR(E&M)-2025, It. No--2.10.1 ]
19Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required. [ DSR(E&M)-2025, It. No--2.11 ]
20Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. [ DSR(E&M)-2025, It. No--2.12 ]40 amps [ DSR(E&M)-2025, It. No--2.12.1 ]
2163 amps [ DSR(E&M)-2025, It. No--2.12.2 ]
22WIRE SOCKET&INSPECTION BOXWiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required [ DSR(E&M)-2025, It. No--1.14 ]2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire [ DSR(E&M)-2025, It. No--1.14.1 ]
232 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire [ DSR(E&M)-2025, It. No--1.14.2 ]
242 X 4 sq. mm + 1 X 4 sq. mm earth wire [ DSR(E&M)-2025, It. No--1.14.3 ]
252 X 6 sq. mm + 1 X 6 sq. mm earth wire [ DSR(E&M)-2025, It. No--1.14.4 ]
26Finishing of the PVC insulated wire ends by socketting with pin/ ring type copper sockets and insulated tapes etc., including supplying sockets, tapes. [F-5/9]i) 1.5 sqmm [NS]
27ii) 2.5sqmm [PWD(El)-Nov-17, Pg.-F-5, It. No.-9(i)]
28iii) 4 sqmm [PWD(El)-Nov-17, Pg.-F-5, It. No.-9(ii)]
29iv) 6 sqmm [PWD(El)-Nov-17, Pg.-F-5, It. No.-9(iii)]
30Supplying and fixing metal box of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc as required. [ DSR(E&M)-2025, It. No--1.22 ]180 mm X 100 mm X 60 mm deep [ DSR(E&M)-2025, It. No--1.22.5 ]
31200 mm X 125 mm X 60 mm deep [ DSR(E&M)-2025, It. No--1.22.6 ]
32MV CABLE SUPPLY, DELIVERY & LAYINGSupplying and delivery of following size Armoured cables XLPE/PVC insulated are designed for 1.1 kV Stranded Aluminium conductor, high tensile galvanized steel wire/strip armour for mechanical protection, and PVC/FR PVC outer sheathing power cable of following size. (IS 7098 Part - 1/2011 with Up To Date Amendments.)4 core 10 sqmm[ Page No-1 of Different type acble, Item-1(1.10)]
334 core 16 sqmm [ Page No-1 of Different type acble, Item-1(1.11)]
34Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. [ DSR(E&M)-2025, It. No--10.1 ]Upto 35 sq. mm [ DSR(E&M)-2025, It. No--10.1.1 ]
35Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. [ DSR (E&M)-2025, Pg.- 68, It. No.-11.1]4 X 10 sq. mm (25mm) [ DSR(E&M)-2025, It. No--11.1.32 ]
364 X 16 sq. mm (28mm) [ DSR(E&M)-2025, It. No--11.1.33 ]
37Supplying & fixing medium gauge GI Pipe ( ISI-Medium) Protection with necessary fittings and jointing metarials as required as per GS.32 mm dia [ F-6/11(b) ]
38LED LIGHT & FITTINGS FIXTURELED Batten light (System lumen efficacy ≥120 <135 lm/Watt)Supplying, installation, Testing & Commissioning of LED surface mounted Batten light of following body material and construction as per IS: 10322 with driver (Replaceable) as per the requirement with Driver efficiency >85% ,Operating voltage AC 140-270 Volt, freq 50/60 hz, Operating temp range -5 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection, THD < 10% , P. F.≥0.95, IP20, CRI ≥80, Flicker free, (flicker should be below 5 %), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with, 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM (Standard Deviation Colour Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard and trade mark certificate (T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect i/c external connections with 1.5 sq. mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 <135 lm/Watt output. LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). [ DSR(E&M)-2025, It. No--8.10 ]Powder coated die cast /Extruded aluminium Body (Thickness ≥ 1.20 mm)18-22 watt [ DSR(E&M)-2025, It. No--8.10.1 ]
3940 watt [ DSR(E&M)-2025, It. No--8.10.8 ]
40S & F of 1X18 W 4 ft tubular LED lamp ( (Make:- Philips CAT No. Master LED tube 1200mm 18W 865T8I-2100lm ) [NS]
41Supply & Delivery of 230V, 10W, B22, W/W LED Lamp [Philips/ Wipro/ Lighting Solution ]
42Supplying and fixing PVC batten/ angle holder including connections etc. as required. [ DSR(E&M)-2025, It. No--1.58 ]
43Supply & Delivery of 10W Bulk Head LED Light Fitting Pressure Die Cast housing LED Bulkhead with IP 66 Protection and IK 09 input resistance suitable for surface and wall mounting applications having luminoius efficacy of 100lm/W [Make:- Signify (Philips) Cat No. WT202W LED10S CW PSU S3 PC/ Wipro/ Havells]
44Supplying, installation, Testing & Commissioning of Flood light LED fixture powder coated pressure die cast aluminum body finish with corrosion resistance fasteners (SS hardware) & silicon gasket for proper sealing with driver as per the requirement with Driver efficiency >80%, Input voltage: 140-270 Volt AC, freq 50/60 hz, Operating temp range 0o to 50o C and working RH 10% - 90%, internal surge protection of 5 KV internal and external SPD min. 10 KV, L,N,E as per IEC 61000-4-5. The driver rated output wattage should be 10% to 15% higher than lamp rating and at least 2 driver for 200W & above and Driver efficiency >85%, THD < 10% as per IEC 61000-3-2 , P. F.≥0.9, IP- 66, IK-08 specified below, CRI >70, under voltage and over voltage protection, high efficiency lens with type II/III distribution as required with UV stabilized optical lens, life time(LED,Driver & electrical circuitry) of minimum 50000 Burning Hours (Life projection shall be calculated as per TM-21 methodology) and 70% of initial Lumen maintained till life ends. CCT 3000°K / 4000°K/ 5700°K /6000°K/6500°K, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect and LED Chips of SMD mid to high-power (2.5 to 4 watt for 200 watt and above, as per required (LM- 80 tested) and necessary inter-connections with 1.5 sq mm FR, PVC insulated copper conductor single core cable and earthing etc. asrequired with Minimum 5 year OEM comprehensive on-site warranty against manufacturing defects including driver and LED module. All test report except L80 should be from 3rd party NABL accredited Lab as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. System lumen efficacy shall be as below: System lumen efficacy ≥135 <135 lm/Watt (Page-6, Item No-7.1)100 watt (Page-6, Item No-7.1.3)
45LED Smart Street light fixture, powder coated pressure die cast aluminium (System. System lumen efficacy >135 lm/Watt) Supplying, installation, Testing & Commissioning of Smart Street light LED fixture, powder coated pressure die cast aluminium body with built in or separate driver as per the requirement (< 700ma), Input voltage: 140-270 Volt AC, freq 50/60 hz, Operating temp range -15 deg to 50 deg centigrade, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2, P. F.≥0.95, IP-66, IK-08, CRI ≥70, under voltage and over voltage - EMC as per CISPR- 15, lenses for beam angle as per IESNA type I/II/III as per the width of the road and the project requirement., suitable to fit in up to 65mm dia pipe, life time of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K/ 4000°K/ 5700°K/6500°K (As per ANSI Bin), Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq. mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy >135 lm/Watt output. LM79 & LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement.(Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). Smart inbuilt controller shall have following features. [ DSR(E&M)-2025, It. No--8.20 ]45 watt [ DSR(E&M)-2025, It. No--8.20.1 ]
46Supplying & Fixing GI waterproof type looping cable box size 200x150x100 mm deep having 4 mm thick comprising of one 250 V 15 A kit-kat fuse unit, one NL on porcelain insulator, one compression type brass cable gland for upto 2- core 16 sqmm PVC/A cable and having lined with rubber gasketted GI top cover with brass machine screws etc., earthing terminal with lug, on steel tubular pole near base, including S&F 40x6 mm thick, MS clamps with bolts, nuts etc. including painting with anticorrosive paint.[H-5/5]
47S&F 50 mm. dia 1.5 mtr. long detachable type G.I. Double arm bracket, suitable for pole head. The arm bracket shall be properly welded with 15 mm. thick stifner plate of pole sleeve for strengthening incl. properly fixing arrangement with the pole by bolts, nuts and washer as per direction of EIC. [NS]
48Installation, testing and commissioning of pre-wired, fluorescent fitting / compact fluorescent fitting of all types, complete with all accessories and tube etc. directly on ceiling/ wall, including connection with 1.5 sq. mm FRLS/HFFR PVC insulated, copper conductor, single core cable and earthing etc. as required. [ DSR(E&M)-2025, It. No--1.41 ]
49Fixing only outdoor / street light type fluorescent light fitting complete with all accessories to be fixed/projected from the wall of the building incl. making holes to building, S&F 40 mm dia GI pipe (ISI-Medium) 1.50 mts. average length, with GI socket at one end and thread at the other end & suitable bend to house the fitting & making necy. connections with S&F necy. length of 1.5 sqmm PVC insulated single core stranded annealed copper wire and making connections as required and mending good damages to wall and painting. [C3(19)]
50Fixing only lamp [C-2/11]
51Fixing only bulk head/ Wall Bracket light fitting on wall /ceiling by screws etc.[C-2/13]
52FAN FITTING & FIXTURESupply & delivery of 230 V, 50 Hz, single phase, 52 watts, 48\\" (1200 mm) Sweep, speed 320 rpm (minimum), A.C. Ceiling Fan and class of insulation: B, 3 nos. metal (Aluminium alloy) blades, 30 cm long down rod (14 SWG & higher thickness), 2 nos. canopies, safety rope, copper winding, steel/Al body. Power Factor not less than 0.9 and minimum air delivery 210 cu.m/min (minimum), without Regulator including capacitor with safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for compliant to IS 374:2019 and external connections with 1.5 sq.mm FR, PVC insulated copper conductor single core cable and earthing etc. as required. (Page-1, Item No-1.2)
53Supplying & fixing Safety arrangement for AC Ceiling Fan by GI Strain Wire of suitable guage with one end fixed at RC clamp with special tye socket/nut bolts thimble which thoroughly crimped with the strian wire passing through down rod and also other end connected with armature spindle by its existing jum nut hole with special arrangement(sample aprove by EIC).the length of strain wire varies as per site situation also considering any type of work required i.e. enlarging the existing holes as per directio of EIC.(Test report of GI wire to be submitted) safety feasibility to be checked by EIC with its application., 2 U Clamp And 1 L Clamp incl all required accessories for fixing safety wire with ceiling fan motor body as per direction by EIC.(aprove make)
54Supplying & Fixing MS fan clamp of two piece type for RC ceiling asper approved specification, fabricated from 40 mm x 9 mm MS flatincluding making good damages to building roof with satisfactoryfinishing and painting – (As per Drawing no. 475 of PWD Specification Book – May 1991). [PWD(El)-Nov-17, Pg.-D-14, It. No.-29]
55Supply & Delivery of 230 V, 50 Hz, single phase, 85 watts, 18\\" (450mm), speed 1325 rpm (minimum), Bracket Fan and class of insulation: B, 4 nos. metal (Aluminium alloy) blades, copper winding, steel/Al body with metal back cover. Power Factor not less than 0.9 and minimum air delivery 110 cu.m/min (minimum), including capacitor with safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for compliant to IS 374:2019 and external connections with 1.5 sq.mm FR, PVC insulated copper conductor single core cable and earthing etc. as required.
56Supply & delivery of 230 V, 50 Hz, single phase, 40 watts , 9\\" (230 mm) Sweep, speed 1350 rpm (minimum), A.C. Exhaust Fan and class of insulation: B, 3 nos. metal (Aluminium alloy) blades, copper winding, steel/Al body. Power Factor not less than 0.9 and minimum air delivery 650 cmh (minimum) including capacitor with safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for compliant to IS 374:2019 and external connections with 1.5 sq.mm FR, PVC insulated copper conductor single core cable and earthing etc. as required. [Make:- Crompton Greaves/EPC/Orient/ USHA ] (Page-2, Item No-2.1)
57Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS/HFFR PVC insulated, copper conductor, single core cable, including providing and fixing phenolic laminated sheet cover on the fan box etc. as required. [ DSR(E&M)-2025, It. No--1.45 ]
58Erection of wall bracket /ceiling fittings of all sizes and shapes containing upto two GLS lamps per fitting, complete with all accessories including connection etc. as required. [DSR(E&M)-25, Pg.--8 , It. No--1.35]
59Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required. [DSR(E&M)-25, Pg.--10 , It. No--1.50]a) Upto 450 mm sweep [DSR(E&M)-25, Pg.--10 , It. No--1.50.1]
60Extra for fixing the louvers/ shutters complete with frame for a exhaust fan of all sizes. [ DSR(E&M)-2025, It. No--1.51 ]
61Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. [ DSR(E&M)-2025, It. No--1.25 ]
62Fixing of Metal Body AC wall bracket fan on wall by S&F rag bolts, nuts & washers (6 mm dia x 62 mm long) on 150mmX300mm best quality vernished wood or as reqd. incl. S&F 24/0.20 PVC insulated flexible copper wire 0.5 mt. length [C-4/29] 16 inch [C-4/29]
63GI OCTAGONAL POLE, BRAKET & ERECTION Supply of 7 mtr. Galvanized Octagonal Pole, Top A/F 70, bottom A/F 155, Thickness 3 mm, Base Plate -225x225x16 Wind speed shall be considered 50m/s as per IS:875 and Supply of 4 No.M20X 700 “J” Type foundation bolts as per EN-B Grade manufactured from special steel along with nuts, washers, Anchor Plate, and templates A) Material Construction Shaft Equivalent to BSEN 10025 Or As per IS 2062 B) Materials grade of Base Plate shall be E250(BR)as per IS:2062 C) Galvanization as per IS 4759 Make :- Surya
64The pole foundation & erection (Civil work) Erection Octagonal pole of length as given below with /without sole place & cap etc in ordinary cement concrete (mix 1:2:4) with graded stone chips (20 mm) foundation of size 0.5m x 0.5m maximum round base block below sole plate /pole jhama metal incl. cc (1:3:6) upto 1 meter
65Supply & Fixing of Ring Type HDG Bracket made of (48.3 ODx2.9 thik.) Mild Steel Pipe as per IS:1161 suitable for install 4-6 Nos LED Flood Light
66Supplying, installation, testing and commissioning of Astronomical time switch of following configuration to be mounted in feeder pillars / Lighting DBs for automatic switching On & OFF of street lights at sun set & sun rise or twilight (Auto ON, Auto OFF, Auto modes) with manual override facility with 12/24 hour display format with suitable battery and indication for relay status i/c programming at site complete as required. [ DSR(E&M)-2025, It. No--7.4 ]output per phase and suitable for single phase supply [ DSR(E&M)-2025, It. No--7.4.1 ]
67S & F 240V Single MF-I starter Cat No. 5594351(make L & T/Siemens/ABB) for Outdoor light
68EarthingEarthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required. [ DSR(E&M)-2025, It. No--5.2 ]
69Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required. [ DSR(E&M)-2025, It. No--5.18 ]
70Excavation of soil for installation of Earth Electrode and filling & ramming. (For Morum Soil) [G-1/1(a)]
71Dismeltening of all existing electrical Items & deposit to the hospital authority Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 58042102
AUTHORITY Government Departments
TENDER VALUE Ref. Documents
LAST DATE 30-10-2026
Authority
Authority Name Public Works Department
Work Description Tender for Repairing And Maintenance Of Civil & Electrical Installation Work In Residential Quarter At Kotshila Rh Under Jhalda-Ii Block, In The District Of Purulia----Electrical Installation Work.
Basic Detail
Tender No WBPWD/EE/PED/NIQ40/2026-2027
Bidding Type Tender
Location
City Purulia
State West Bengal
Key Dates
Publish Date 14 Oct 2026
Submission Date 30 Oct 2026
Open Date 02 Nov 2026
Finance
Tender Value Ref. Documents
Tender Fee Ref. Documents
EMD 27219
Exemption Not Available
Document List
2911_ii.pdf
b5e1bcdc-289c-4059-be11-0fa125b36f22.html
BOQ_5185946.xls
OID.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Oct 14, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Oct 30, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 12 days
Nov 02, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 15 days

Tender Documents

Download All (ZIP) ↓
pdf

2911_ii.pdf

html

b5e1bcdc-289c-4059-be11-0fa125b36f22.html

xls

BOQ_5185946.xls

pdf

OID.pdf

pdf

Tendernotice_1.pdf

Disclaimer