Defence Statutory Bodies & Commissions/Committees Closing in 5 days TDR #58041453

Tender For Special Repair To Bldg No P-200 Under Ge Shillong

Issued by Statutory Bodies & Commissions/Committees · East Khasi Hills, Meghalaya
Tender Value
26.80 Lakhs
Estimated cost
Bid Submission
04 Nov 2026
5 days left
EMD
53600
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
East Khasi Hills → Meghalaya
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender For Special Repair To Bldg No P-200 Under Ge Shillong

BOQ

Name of Work:- SPL REPAIR TO BLDG NO P-200 UNDER GE SHILLONG
Sl. No. Item Description
1Demolition of PCC block masonry, brick work or stone masonry built in cement mortar including all quoins arches, pillar etc but excluding ashlar facing , dressed stone work and precast concrete articles, complete all as specified and directed.
2Demolition of plain cement concrete (unreinforced) in ground floors or above ground floor and pavings n.exc 15 cm thickness (Below or above ground level) complete all as specified and directed.
3Demolition of cement concrete (reinforced) of any description and in any position not otherwise specifically provided for complete all as specified and directed.
4Taking down chowkhat with shutter (without taking off shutter from the frame) and area n exc 1.5 sqm each including making good disturbed surfaces complete all as specified and directed.
5Taking down chowkhat with shutter (without taking off shutter from the frame) and area exc 1.5 sqm but n.exc 4 sqm each including making good distyrbed surfaces complete all as specified and directed.
6Dismantling floor, hearth , wall tiling including cement mortor bedding (but not backing) removing serviceable tiles to store and rubbish off the premises complete all as specified and directed.
7M&L for dark shade virified Ceramic tiles 10 mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, in floors, dados, etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match laid over and including15 mm thick cement screed bed in CM 1:6 complete all as specified and directed.
8M&L for pre-cast PCC solid block walling with cement concrete type C1 (1:3:6, using 20 mm graded crushed stone aggregrates) exc.10cm in width and setting in cement mortar 1:6, complete including demolition at old precast cement concrete block walling complete all as specified and directed.
9M&L for RCC (nominal mix) 1:1.5:3 Mix, Type A1 (Using 20mm graded crushed stone aggregates) as in beams, lintel band over 1.50m clear span complete all as specified and directed.
10M&L for RCC (nominal mix), 1:1.5:3 Mix, type A-1 (using 20 mm graded crushed stone aggregate) as in Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs, drain covers and in shelves and the like complete all as specified and directed.
11M&L for PCC 1:4:8 Mix, type D2 (using 40mm graded crushed stone aggregate) as in foundations, fillings and mass concrete complete all as specified and directed.
12S&F TMT steel bars 10mm dia and over as in reinforcement, cut to length, bent to shape required including cranking, bending spirally or hooping for fencing, columns, beams, etc. hooking ends and binding with MS wire (annealed not less than 0.9mm dia) complete all as specified and directed.
13All as per item No. 12 here in before but 5mm dia and over upto and including 10mm dia as in stirrups, spacers and binders etc complete all as specified and directed.
14M&L for formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including sup- ports, overhangs, etc. also splays between floors and beams, etc. fair finished surfaces of concrete flat complete all as specified and directed.
15M&L for Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping) incl fair finished surfaces of concrete flat complete all as specified and directed.
16S&F Aluminium (extruded section body) door closer hydraulically regulated, designation No. 3, universal type, suitable for door shutters of 851 to 1000 mm in width and of weight between 61 to 80 kg and fixed complete all as specified and directed.
17M&L for 20 mm thick Granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window- cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite complete all as specified and directed.
18M&L for rendering 15mm thick in CM 1:4 on fair faces of brick work or concrete surfaces complete all as specified and directed.
19M&L for rendering 10mm thick in CM1:6 on fair faces of brick work or concrete surfaces complete all as specified and directed.
20M&L for Providing and fixing factory made UPVC white color Sliding window Two track made of extruded profiles with wall thickness of 2.3mm (+- 0.2mm). Window profile with hollow section with multi chamber, Frame (60mm x 62mm). sash (42mm x 67mm). Sliding Interlock (One vertical length in each shutters) (45.5mm x 28mm). Glazing bead (24.5mmx 16mm) will he mitered cut and fusion welded at all corners, including drilling of holes for fixing hardware and drainage of water etc.. making arrangement for fixing of hardware. EPDM gasket 1.2 + -0.2mm thick galvanized steel frame (30mm x 21.5mm), Sash (30mm x 18mm), profile to be inserted in required profile, frame will be fixed to the wall with 8mm x 100mm long fasteners. Hardware : [Touch Lock of zinc alloyed (white powder coated), steel roller system including 5mm thick glazing with selected quality glass, aluminum track on bottom rail for two track sliding frame, wool pine for Sliding sash and interlock. Note: The unit rate quoted by contractor excludes cost of glass and includes frames & all other connected accessories. Net opening will be measured for payment purpose.(ii) Area not exceeding 2.00 sqm each complete all as specified and directed.
21M&L for Providing and fixing factory made uPVC white colour fixed window made of extruded profiles with wall thickness of 2.3mm(+-0.2mm). Window profile with hollow section with multi chamber. Frame (60mm x 58mm). T profile (Onevertical length in between two shutters) (60mm x 74mm). Glazing bead (35mm x 20mm) will be mitered cut and fusion welded at all corners, including drilling of holes for fixing hardware and drainage of water etc. making arrangement for fixing of hardware, EPDM gasket. 1.2 +–0.2mm thick, galvanized steel Frame (28mm x 21.5mm), T profile (27mm x 17 mrn) to be inserted in required profile, frame will be fixed to the wall with 8mm x 100mm long fasteners- 5mm thick glazing with selected quality glass complete all as specified and directed. Note: The unit rate quoted by contractor excludes cost of glass and includes frame & all other connected accessories. Net opening will be measured for payment purpose.(ii) Area not exc 1 sqm of each window.
22M&L for Providing and fixing factory made uPVC white colour casement (Openable) Door made of extruded profile wilh wall thickness of 2.3mm ( + -0.2mm). Window profile with hollow section with mitlti chamber, frame (60mm x 58mm), sash (60mm x 78mm). T profile (One vertical length in between two shutters) (60mm x 74mm). Glazing bead (35mm x 20mm) will be mitered cut and fusion welded at all corners, including drilling ol holes for fixing hardware and drainage of water etc., making arrangement for fixing of hardware. EPDM gasket 1.2 + -0.2mm thick galvanized steel Frame (28mm x 21.5mm), sash (31mm x 27mm), T profile (27mm x 17mm) to be inserted in required profile, frame will be fixed to the wall wilh 8mm x 100mm long fasteners. Hardware: [casement door handle made of zinc alloyed (white powder coated). Corner striker. Secondary Strikers. Cylinder. Door transmission gear made of mild sleel with multi point locking system with strikes. 3D Hinges of zinc alloyed (white powder coated) [and 5mm thick glazing with selected quality glass. Note: The unit rate quoted by contractor excludes cost of glass and includes frames & all other connected accessories. Net opening will be measured for payment purpose.
23S&F 2nd class hard wood plain, solid, straight chawkhats and frames, wrought, framed, rebated on the solid rounded or chamfered, put together with glue pinned at joints complete all as specified and directed.
24S&F40mm thick (factory made) flush shutter solid core construction with block board core and plywood face panels, decorative face veneer with lipping / frame to match on both sides complete all as specified and directed.
25M&L for plain fillets, square rectangular or triangular in section clean sawn secured with nails or brads (2nd class hard wood) sectional area exc 13 sqm n exc 25 sqcm complete all as specified and directed.
26S&F hollow / insulated PVC Wall panelling consisting of 10mm thick plain colour PVC sheet, suitably fixing/placed at site on walls/false ceiling including grid made of Aluminium/G.I./M.S. as per specification and drawing complete all as specified and directed.
27S&F powder coated anodized aluminium frame for doors/windows /ventilators/, partitions with one or more rebates including joining cleats for fixing to existing tiled/concrete floring as required. etc complete all as specified and as directed. Note : Any damage made to existing flooring with fixing frames shall be made good by contractor without any extra cost and match with existing flooring.
28M&L block boards, grade 2 quality, interior grade, decorative type with decorative face veneer on both face complete all as specified and directed.
29M&L for second class hard-wood scantlings, wrought timber fixed and framed complete all as specified and directed.
30S&F 12 mm thick veneered decorative plywood, grade 1 (with BWR resin) with decorative face veneers on both faces; fixed with screws to timber frame works complete all as specified and directed.
31S&F Magnet catches for cupboard shutter, brass body and striking plate including letting in complete all as specified and directed
32S&F Continuous (Piano) hinges, brass, width of flaps 30 mm (when open) complete all as specified and directed.
33S&F Sheet glass, 4.8mm thick ordinary quality, in squares, n exceeding 0.50 sqm in each pane including rubber packing and aluminium beading complete all as specified and directed
34S&F Butt hinges, medium weight, cold rolled mild steel, size of hinges 100mm complete all as specified and directed.
35S&F Extruded Aluminium, anodised, bow handles of size 150mm complete all as specified and directed.
36S&F Extruded Aluminium, anodised, bow handles of size 75mm complete all as specified and directed.
37S&F mild steel mortice lock 4-levers vertical type of size 100 mm complete all as specified and directed.
38S&F floor door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring, fixed in floor, overall length of cover plate 140mm complete all as specified and directed.
39M & L for preparation of newly plastered surfaces of walls including cornices, pilasters etc and applying two coat of cement paint, white or tinted over new surface or previously untreated surfaces over a coat of primer complete all as specified and directed
40M&L for preparing old painted surfaces of wall / ceiling and distempering with 1st quality oil emulsion distemper, white or tinted, two coats complete all as specified and directed.
41M&L providing and applying plaster of paris putty of 1 mm thickness over plastered surface to prepare the surface even and smooth complete all as specified and directed.
42M&L preparing old wall surfaces by washing rubbing down and stopping of distempered or any painted surfaces and priming with alkali resistant primer paint and two coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces complete all as specified and directed.
43M&L for cleaning and forming fair finished drain or channel 30 cm inner girth in cement concrete, using extra cement, including forms, moulds, miltred/stopped ends etc complete all as specified and directed.
44M&L for 75 mm thick PCC, 1:3:6 Mix, type C2 (using 40mm graded crushed stone aggregate) as in plinth protection including finishing the surfaces even and smooth without using extra cement including demolition of old PCC as in plinth protection complete all as specified and directed
45M&L for PCC 1:3:6 Mix, type C-2 (using 40mm graded crushed stone aggregate) as in surface channels and drains incl framing complete all as specified and directed.
46M&L for carrying out water proofing treatment to roof surfaces as under:-a) Surface Prep: Ensure the RCC roof is clean, dry, and free from loose material, dust, or oil.b) Crack Repair: Seal cracks with Sikadur-20 Crack Seal or a similar sealant.c) Primer Application: Apply a suitable primer (like Sikalastic-11 Primer W) to enhance adhesion.d) Base Coat: Apply the first Sikalastic-560, generous coat with the help of roller.e) Reinforcement: While the base coat is still wet, embed Sika Reemat/Fleece-120 (fiberglass reinforcement) into the coat to enhance tensile strength.f) Top Coat: After the first coat has dried (typically touch-dry), apply a second of Sikalastic-560, top coat of the liquid membrane in a perpendicular direction to the first coat to ensure 100% coverage.g) The entire item to be executed through certified specialist firm/expert person with warranty of 5 yrs.
47S&F vitreous china WHB, white, flat back, of size 550 x 400 mm including brackets, waste coupling 32mm, and waste Pipe, 32mm incl pedestal complete all as specified and directed.
48S&F PVC Connections 15mm size with PTMT Nuts of length 450mm and fixed, complete all as specified and directed.
49S&F steel connections 15mm size with CP Nuts of length 450mm and fixed, complete all as specified and directed.
50S&F brass CP mixer (wash basin) for mixing hot & cold water screwed down for iron pipe and fixed complete all as specified and directed.
51Taking up or down steel tubing and disconnection, for 15mm bore of pipes complete all as specified and directed.
52Taking up or down steel tubing and disconnection, for 20mm bore of pipes complete all as specified and directed.
53Supply and Laying Steel Water Tubing 15mm dia (Bore), Galvanised, ‘Medium Grade’ with all Fittings, fixed on Walls, Ceiling or laid in Floors or any other Situation, complete as all specified and directed.
54Supply and Laying Steel Water Tubing 20mm dia (Bore), Galvanised, ‘Medium Grade’ with all Fittings, fixed on Walls, Ceiling or laid in Floors or any other Situation, complete as all specified and as directed.
55M&L for 110 mm PVC (SWR) pipes single socketed in any length with rubber ring joints inc bends, laid in trenches or in floors complete all as specified and directed.
56M&L for 75 mm PVC (SWR) pipes single socketed in any length with rubber ring joints inc bends ,laid in trenches or in floors and connect to running sewage line/mainhole/septic tank complete all as specified and directed.
57S&F 110mm bore PVC (SWR) bends any radius complete all as specified and directed.
58S&F 75mm bore PVC (SWR) bends any radius complete all as specified and directed.
59Supply hoisting and fixing rotational moulded HDPE water storage tank after disconnecting of old tank,double layer ,ISI marked (cylendrical vertical type with closed top) of capacity 1000 ltrs in position incl float valve high pressure of PTMT with epoxy coated aluminium rod & high-density plastic ball screwed for iron pipe and fixed incl dismantling of tank complete all as specified and directed.
60Taking down carefully copper/aluminum point wiring light/fan/sockets out let/power point complete (fittings such as switches, sockets, ceiling rose, pendent holders, light fittings etc. are to be measured separately) and/or drawing out from existing conduit/batten and making good disturbed surfaces of walls/floors/ceiling, complete all as specified and directed.
61Material and labour for Point wiring with 1.50 Sqmm single core PVC insulated , unsheathed cable FRLS, 1100 volt grade with multi stranded copper conductor drawn through and incuding medium grade, ISI marked, including 20 mm dia PVC Conduit on wall/ceiling and incuding provision of 1.50 Sqmm single core PVC insulated , unsheathed cable FRLS, 1100 volt grade with multi stranded copper conductor green colour as earth continuity conductor and connected to common earth dolly with suitable size of lugs, including mild steel sunken box/metal flush box with suitable steel terminal boxes made out of 1.6 mm thick mild steel sheet metal conforming to IS-5139(pt-I) of 1969 and IS:14772-2000 with earth dolly and coated with two coats of anti corrosive paint over a coat of red oxide primer both internally and externally including provision of new 3 mm thick plastic laminated sheet top cover for housing the switches , socket outlets, fan regulators etc. with brass screws and brass washers and making good the disturbed surfaces as per existing for one light/Fan point controlled by one switch complete all as specified and directed.
62Description all as per Srl item No. 61 here in before but for one bell point controled by one bell push .
63Description all as per Srl item No. 61 here in before but for socket outlet point 5 Amp on Independent board.
64Description all as per Srl item No.61 here in before but for socket outlet point 5 Amp on same board.
65Description all as per serial item No 61 above but with 4 sqmm cable for 3 pin 15 Amps switch socket outlet (Power point) complete all as specified and directed.
66Supply and fixing modular switch 1 way, 6 A, 1 module 230/250 volt, AC supply, ISI Marked, with cover plate complete all as specified and directed.
67Supply and fixing Bell push, flush type, 6 A, 1 module 230/250 volt with frame and cover complete , AC supply, ISI Marked, with cover plate complete all as specified and directed.
68Supply and fixing modular sockets 6A 2/3 pin combined 2 module, with frame and cover complete 230/250 Volts, 50 Hz , AC supply, ISI Marked, with cover plate complete all as specified and directed.
69Supply and fixing modular sockets 6A/16A 2/3 pin combined 2 module with frame and cover complete 230/250 Volts, 50 Hz , AC supply, ISI Marked, with cover plate complete all as specified and directed.
70Supply and fixing modular switch 16A 1 module with frame and cover complete 230/250 Volts, 50 Hz , AC supply, ISI Marked, with cover plate complete all as specified and directed.
71Supply and fixing call bell ding dong, AC, 230 V, Single pole ISI marked all as specified and directed.
72Supply and fixing LED batten with Extruded aluminium for proper heat dissipation 18/20 watt with CCT 3000K/6000K (Warm white/Cool white). The Driver must be integrated electronic driver with inbuilt 4KV Surge protection. Lumen efficancy must be 100 Lumens per watt for Cool white and 90 Lumene per watt for warm white complete all as specified and directed.
73Supply and fixing LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed.
74Supply & fixing 6W Recess fittinge Round LED Down light with Extruded aluminium Housing, PC Diffuser, LED life span > 50000 burning hours, CCT-6000K/4000K/3000K (Cool white/Natural White/Warm White) Lumen efficacy 110Lm/105 Lm/1000 Lm Lumens per watt, CRI>80, Driver Efficiency>85% over voltage Protection upto 440V/AC for 4 years, surge Protection 4 KV, IP20, IK02 complete all as specified and directed.
75Supply & fixing 12W Recess fittinge Round LED Down light with Extruded aluminium Housing, PC Diffuser, LED life span > 50000 burning hours, CCT-6000K/4000K/3000K (Cool white/Natural White/Warm White) Lumen efficacy 110Lm/105 Lm/1000 Lm Lumens per watt, CRI>80, Driver Efficiency>85% over voltage Protection upto 440V/AC for 4 years surge Protection 4 KV, IP20, IK02 complete all as specified and directed.
76Supply & Fixing of up down LED light 2X6 Watt with CCT 3000K warm white, IP 54 Dia Cast aluminium housing, transparent tempered glass diffuser complete all as specified and directed.
77Supply and fixing ceiling rose surface bakelite 65x50mm, 3 terminal complete all as specified and directed.
78S & F Exhaust fan 230 volts, 250mm,plastic body including making all electric connection complete all as specified and as directed including cutting of hole on wall and makng good disturbed surface of wall and outer wooden box for fan fix on wall complete all as specified and directed.
79Supply and fixing of hot water Geysers of 25 ltrs capacity 5 star rated vertical type includng fixing of bolts , nuts grouted into the wall , and necessary cement work , making good of disturbed surface of wall , giving electric and water connection and testing after installation complete all as specified and directed.
80S&F heat resistant UPVC connection pipe for hot and cold water 450mm long 15mm dia complete all as specified and directed.
81Supply and Fix of Angle stop valve of PTMT any colour high pressure screwed for iron pipe and fixed, (Minimum weight 15mm-90gms) complete all as specified and directed
82Supply and fix bib tap 15mm dia, outer thread, cst copper alloy chromium plated complete inclusive 15mm dia GI socket and all incoming water connection and testing complete all as specified and directed.
83Supply and fix epoxy powder coated sheet metal enclosure for DBs, double door, Single pole and neutral 240 V, 12 ways with mounting fitted with bus bar, DIN channel , neutral link and incoming contact including taking down old unserviceable one including MCBs complete all as specified and directed.Notes : (i) MCB SP/TPN shall be measured and paid separately under appropriate items of this schedule . (ii) Copper thimble shall be used for connection of cable .
84Supply and fix in repairs MCB DB 4 way vertical sheet metal enclosure TPN 415 volts, 50 Hz, with IP-43 protection, double door with 200 Amps standard bus bar of suitable size and common neutral link all enclosed in standard sheet flush mounting complete all as specified and directed. . Notes : (i) MCB SP/TPN shall be measured and paid separately under appropriate items of this schedule . (ii) Copper thimble shall be used for connection of cable .
85Supply and fix MCCB TPN, 240 Volts, 100 Amps, 10 kA rupturing capacity415 Volts complete all as specified and directed
86Supply and fix MCB DP, 240 Volts, 40 Amps, 10 kA rupturing capacity 'C' series complete all as specified and directed
87Supply and fix in repairs MCB, single pole 240 volts 6 to 32 Amps capacity fixed in DB's.complete all as specified and directed
88M & L Sub main wiring with two run single core 6 Sqmm FRLSH copper conductor cable PVC insulated, unsheathed, 1100 V including 20 mm dia PVC Conduit on wall/ceiling in ISI marked with all accessories such as Tees, elbows, junction boxes etc, as required fixed on wall alongwith one run of 6 Sqmm single core PVC FRLSH insulated unsheathed copper conductor cable as continuous earth wire and connecting to existing main switch board / distribution board and testing on completion inculding taking down old wiring etc complete all as specified and directed.Note: (i) Two runs of 6 sqmm and one run of 6 sqmm cable and one run of PVC conduit shall be measured as one RM.
89M & L Sub main wiring with two run single core 4 Sqmm FRLSH copper conductor cable PVC insulated, unsheathed, 1100 V including 20 mm dia PVC concealed on wall/ceiling in ISI marked with all accessories such as Tees, elbows, junction boxes etc, as required fixed on wall alongwith one run of 4 Sqmm single core PVC FRLSH insulated unsheathed copper conductor cable as continuous earth wire and connecting to existing main switch board / distribution board and testing on completion inculding taking down old wiring etc complete all as specified and directed.Note: (i) Two runs of 4 sqmm and one run of 4 sqmm cable and one run of PVC conduit shall be measured as one RM.
90Material and labour for earthing complete with galvanised steel earth plate electrode 60 Cm X 60 Cm X 6 mm buried directly in ground vertically to a depth notless than 2.25 mtr deep below ground level with top edge of earth plate at a depth not less than 1.5 m below normal ground level connected to galvanised earth lead wire 4.0 mm dia by means of bolts, check nuts and washers ,galvanised steel and protected by GI pipe 15 mm bore light grade & connected to main switch board or main control board as directed and including concrete pit in PCC (1:3:6) type C1, precast RCC (1:2:4) type B1 cover slab 30 cm X 30 cmX 5 cm with 10mm dia TMT bars 8 cm C/c both ways and one handle for lifting made out of 8 mm dia TMT bar, funnel, wire mesh, 20mm bore galvanised iron pipe (medium grade) for watering, charcoal or coke and salt in alternative layers, necessary excavation and earth work in any type of soil and including necessary testing complete all as shown in Electrical Plate No 3 of SSR part -I all as specified and directed.
91Supply and fix / lay in tranches, on floors ,fix on wall/pole, passing through pipes, in air etc.,LT UG cable , 1100 volts grade, PVC/ XLPE insulated , with multistranded aluminium conductors, armoured with galvanised steel wire or tape ,gland, lugs etc, of size 35 Sq.mm 3.5 core , confirming to IS specification complete all as specified and directed.
92Excavation in trenches not exc 1.5 m wde and 1.5 m deep for taking out/laying of UG cable/GI pipe of any dismeter in soft/loose soil and getting out complete all as specified and directed
93Returning and filling including spreadking levelling watering and well ramming in layers not exc 25 cm thick soft/loose soil complete all as specified and directed
94Removing excavated material at a distance n exc 50m and deposited where directed at a level not exc 1.5 above the starting point for soft/lose soil complete all as specified and directed
95M & L for sand filing in trenches for providing sand cushion for protection of UG cable complete all as specified and directed. Note: Thickness of sand shall be measured after punning.
96Supply and laying of sub class B bricks locally available laying perpendicular of UG cable complete all as specified and directed.
97M&L for fixing in replacement GI tubing 50 mm bore light grade, on poles, on walls, under floors, road crossing as reqd at site complete all as specified and directed. NOTE FOR ALL ITEMSIn case in BOQ any item found repeated and contractor quotes different rate for the same, the rate quoted on lesser side shall only be applicable for payment and no claim whatsoever on this account shall be entertained by the Department. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 58041453
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 26.80 Lakhs
LAST DATE 04-11-2026
Authority
Authority Name Military Engineer Services
Work Description Tender For Special Repair To Bldg No P-200 Under Ge Shillong
Basic Detail
Tender No GE/SHL/TOKEN-93 OF 2026-27
Bidding Type Tender
Location
City East Khasi Hills
State Meghalaya
Key Dates
Publish Date 14 Oct 2026
Submission Date 04 Nov 2026
Open Date 05 Nov 2026
Finance
Tender Value 26.80 Lakhs
Tender Fee 500
EMD 53600
Exemption Available
Document List
7bdf1bb0-32e7-4ab7-863d-7ef9ec4c4e5d.html
BOQ_890437.xls
TENDERDOCU93.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Oct 14, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Nov 04, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 5 days
Nov 05, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 6 days

Tender Documents

Download All (ZIP) ↓
html

7bdf1bb0-32e7-4ab7-863d-7ef9ec4c4e5d.html

xls

BOQ_890437.xls

pdf

TENDERDOCU93.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender