BOQ
| Sl. No. | Item Description |
| 1 | B/R PORTION |
| 2 | Taking down/out loose & damaged concrete/cement plaster from soffits of ceilings, floor/roof slabs, vertical surfaces of columns, beams etc., including exposing and removing rust from the reinforcement by rubbing with wire brush and removal of debris to a distance n. exc. 100 mtr and depositing where directed |
| 3 | M/L for gunniting exposed concrete surfaces of beam, column and slabs with one layer of complast spray set modified concrete in proportion (50Kg cement 3 to 6mm granite chips 75 kg zonal sand 75 kg and complast 2% by weight of cement water 1 to the following locations :- |
| 4 | 40 mm thick in columns |
| 5 | 30 mm thick in beams |
| 6 | 20 mm thick in slabs |
| 7 | S&F hard drawn steel wire fabric cut to length bent to shape required and tying with and including mild steel wire (annealed) not less than 0.9mm dia not exc. 4 Kg/sqm. |
| 8 | Bonding the entire exposed surface with one coat of fosroc Nitop bond SBR as per manufacturer insltructions over where fabric and surfaces of concrete structure |
| 9 | Dismantling plain or corrugated steel sheeting any gauge, thickness, including Naintal or similar pattern roof coverings |
| 10 | S&F Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified |
| 11 | S&F Pre- painted galvalume aluminum zinc coating GI based plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified |
| 12 | Taking down eaves gutters and rainwater pipes (any size or pattern), including all fittings, heads, shoes, bends, swan-necks, etc., including cleaning or refixing or removal to Store (measured overall as fixed along the centre line over fittings and accessories) |
| 13 | S&F PVC Rain Water Pipe 150 mm dia including all fittings, head , shoes, branches all as specified fixed in wall including joint with PVC adhesive |
| 14 | S & F 110 mm bore PVC (SWR) Soil, waste and vent pipes single socketed in any length with rubber ring joints fixed to walls. |
| 15 | S & F 110 mm bore PVC (SWR) Bends |
| 16 | Dismantling mild steel work of any description not otherwise provided for |
| 17 | S & F Mild steel roof trusses (framed), Trussesd, purlins, crane grantries, rails and framings and heavy bracket framing (Beam,tee, angle, channel or flat sections) confrming to Fe 410-W including cleats,distance pieces etc |
| 18 | Dismantling Wall and ceiling boards/ wall lining (fibre, pulp, insulation, etc.) or insulation boards/ slabs/ blankets/ paneling, any thickness, including cover fillets |
| 19 | S&F for Solid PVC Wall Lining consisting of 5mm thick single side prelam PVC sheet including of solvent cement and fixing at site on PVC frame as per specifications and drawing |
| 20 | S&F for 5mm thick PVC sheet fillet of width 35mm for wall paneling inclusive of fixing on to wall to make PVC Frame as per specification and drawing. |
| 21 | Taking down ceiling board/tiles from aluminium snap grid frame work and refixing the same in the same position after necessary tightening the sagging portion, replacement of the ceiling board, Main Tees, cross Tees, angles, suspending if required, including bolts, necessary washer,nut/clits/pin hook etc for securing frame work to ceiling to the snap grid all as directed by Engineer in Charge. |
| 22 | S&F for 12mm thick Perforated particle board/ ANF board/ tiles for insulation and accoustic purposes, 60x60 cm in size, fixed with nails to timber frame work or with staples on snap grid fixed (Note: Aluminium grid shall be measured seperately under relevant item of this Schedule.) |
| 23 | S&F Anodised aluminium snap grid frame work for false ceiling including necessary fitting all as specified |
| 24 | Taking down Chowkats or frames not exceeding 1.5 Sqm each (Without taking off shutters from the frames) |
| 25 | Taking down chowkat or frames exc 1.5 sqm but n. exc 4 sqm each (w/o taking off shutters from the frame ) complete all as specified and directed. |
| 26 | Taking down shutter exc 1 Sqm and n.exc 2 sqm each and refixng in same position all as specifed and as directed. |
| 27 | Supply & Fixing Powder coated (minimum thickness of powder coated 50 micron) Aluminium anodised frame for door, windows, ventilators with one or more rebates including joining cleat for fixing etc. complete architectural drawings and the directions of Engineer -in-charge.Note:(a) Item shall be paid as per D1 act weight of aluminium section.b) The rate shall be inclusive of the locking arrangement including required builder hardware complete packing with silicon gel around contacting surfaces of aluminium work, and including matching the existing surface area. |
| 28 | Supply & Fixing Powder coated Aluminium (minimum thickness of powder coating 50 micron) for shutters (opening/sliding) for doors, windows and ventilators including providing and fixing hinges/pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber/ neoprene gasket required (fittings shall be paid for separately) with extruded built up standard tubular sections/appropriate Z sections and other sections of approved making conforming to IS 733 and IS 1285, fixing with dash fasteners of required dis and size, including necessary filling up the gaps at junctions i,e. at top , bottom and sides with required EPDM rubber/neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/paneling, CP brass/ stainless steel screw all complete as per architectural CONTD. |
| 29 | drawings and the directions of Engineer -in-charge.Note:a) Glazing shall be measured seperately.b) Item shall be paid as per D1 act weight of aluminium section.c) The rate quoted shall be inclusive of neoprene beading, glazing clips, screws, etc., as required which shall not be measured for arriving the weight.d) The rate shall be inclusive of the locking arrangement including required builder hardware complete packing with silicon gel around contacting surfaces of aluminium work, and including matching the existing surface area. |
| 30 | S &F Aluminium powder coated grill model / design no DG 104 ( 10 mm thick ) with DL-102 frame all as specified and as directed. Make: Decogrill or equivalent as approved by GE. |
| 31 | S &F Sheet pin headed figured glass ordinary quality ,4 mm thick and glazing with oil putty /wooden / metal beads in squares exceeding 0.50 Sq m each all as specified and as directed. |
| 32 | All as per Item No 27 here in before but not exceeding 0.5 sqm each pane all as specified and as directed. |
| 33 | M & L for Solid (125mm x 65 mm Double Rebate) Factory made 100% solid WPC Door frame made from 100% LEAD FREE (Single extruded process) material with density 780kg / Cum & manufactured by an ISO: 9001-2015 certified company, all as per specification drawings as directed by the Engr-in-Charge. The door frame should be water proof, Termite proof, Fire retardant and having excellent screw holding capacity and shall be fixed with 6 Nos 150mm long hole fasterners complete all as specified and directed.Make Rajshree Plastiwood, Kumar Arch TechPvt Ltd, Archid Ply, Floresta |
| 34 | M & L for Solid (100 mm x 65 mm single rebate) factory made 100% solid WPC brown door frame made from 100% LEAD FREE (Single extruded process) material with density 780 kg / Cum & manufactured by an ISO: 9001-2015 certified company, all as per specification drawings as directed by the Engr-in- Charge. The door frame should be water proof, termite proof, fire retardant and having excellent screw holding capacity and shall be fixed with 6 Nos 150mm long hole fasterners complete all as specified and directed. Make Rajshree Plastiwood, Kumar Arch TechPvt Ltd, Archid Ply, Floresta |
| 35 | M & L for 30 MM thick moulded plain WPC solid door shutter: Providing (30mm thick) MOLDED WPC Brown factory made 100% solid door (Conforming As per IS: 4020) made from 100% LEAD FREE single extruded with 2, 4 or 6 raised panel design on the front side with 10mm deep mould on single side with wood grain texture and back side plain with density not less than 600kg/ Cum. Manufactured by an ISO: 9001-2015 certified company. The door should be water proof, termite proof, fire retardant and having screw holding capacity. complete all as specified and directedMake Raj Shree Plasti wood / Sintex / Floresta / Kumar arch Tech Ltd |
| 36 | Providing and fixing 32mm thick brand factory made wire mesh solid WPC door shutter consisting of frame made out of M.S. tubes of 19 gauge thickness and size of 20mm x 40mm for stiles and 20mm x 40mm for top, lock & bottom rails. M.S. frame shall have a coat of steel primers of approved make and manufacturer. 20mm x 40mm M.S. square tubes shall be covered with 6mm thick heat moulded WPC prelaminated 'C' channel of size 30mm thickness, 140mm width out of which 125 mm shall be flat and 15mm shall be bent in 90° angle on either side forming stiles & 6mm thick 165mm wide WPC sheet out of which 150mm shall be flat and 15mm shall be bent in 90° on the inner side to from top and bottom rail and 180mm wide wpc sheet out of which 150mm shall be flat and 15mm shall be bent in 90° on both side to from lock rail. 12mm (6mm x 2) thick, 20mm wide cross WPC sheet as gap insert for top rail & bottom rail. Panel will be of stainless steel. CONTD TO 32.02 |
| 37 | Wire mesh of 24 gauge to be fitted in by 'C' channel of size 32mm x10mm on the either side in the stiles. The inner side 'C' channel is fixed by 20mm x 40mm MS tube on both sides with screws. The wire mesh in top, bottom & lock rail is sealed with 20mm x 40mm tube with stainless steel, wire mesh. 12mm (6mm x 2) thick PVC strip of 20mm width is to be stuck & nails on both side of stainless steel wire mesh gauge interior at the top, bottom & lock rail. 10mm x 20mm stainless steel pipe grill fix with MS frame for support wire mesh as per slected design an additional 6mm thick WPC strip of 22mm width is to be stuck on the interior side of the 'C' channel using solvent cement adhesive etc, complete as per direction of the site engineer. |
| 38 | S&F in repair stainless steel wire mesh 0.36mm nominal dia of wire and avg width of aperture 1.4mm cut to size and fixed to doors/window shutters and fixed with aluminium wire staples as ordered. |
| 39 | S&F mild steel works as in bands, straps, clamps hold fasts and similar small articles conforming to Fe 410-0 or Fe 310-0 |
| 40 | S&F solid PVC door frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with MS square tube all as specified and as directed. |
| 41 | S&F Factory made solid panel PVC door shutter 30mm thick (style) consisting of frame made out of MS tubes for top and bottom rails, MS frame shall be covered with head moulded plain colour PVC 'C' channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rain & bottom rail paneling of plain gap insert for top rail & bottom rail paneling of plain color PVC sheet to be fitted in the MS frame welded/sealed to the stiles & rails with suitable PVC sheet beading and jointed together with solvent cement all as specified. |
| 42 | M&L for PCC (1:2:4) type B1 using 20 mm graded aggregate as in bed block/hold fast blocks,benching and coping etc with & including necessary form work for fair faces of concrete, complete all as specified and directed. |
| 43 | S & F 150 mm long Aluminium, anodised, barrel tower bolts of extruded section |
| 44 | S&F butt hinges medium weight stainless steel 100 mm size |
| 45 | S & F 150 mm long Extruded Aluminium alloy handles, fabricated type, anodised. |
| 46 | S & F 100 mm long Extruded Aluminium alloy handles, fabricated type, anodised. |
| 47 | S&F in repairs Aluminium alloy powder coated sliding door bolt 300 mm long with hasp & staple (bolt type) and fixing clips of sheet cast or extruded section and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy. |
| 48 | S & F in repairs of floor door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring, fixed in floor with overall length of vover plate 140 mm |
| 49 | S & F 25 mm dia., Aluminium alloy anodised fency curtain rails with brackets fixed in repair |
| 50 | Hacking out old broken glass (any thickness, size, quality or description) from wooden frames or stone, concrete or brick surrounds, glazed with putty or fixed with beads. |
| 51 | S&F 4mm thick sheetglass ordinary quality exceeding 0.5 sqm each pane |
| 52 | S&F in repairs aluminium (die cast) body door closer hydraulically regulated designation No 3, universal type suitable for door shutters of 851 to 1000 mm in width and of weight between 61 to 80 kg complete all as specified and directed. |
| 53 | Demolition of un-reinforced Cement Concrete of any description and in any position not otherwise specifically provided for. |
| 54 | M&L for 75 mm thick Cement concrete type C2, 1:3:6 (using 40 mm graded stone aggregate) in plinth protections/hardstanding, finished even and smooth w/o using extra cement |
| 55 | M&L sand filling under floors or in foundations including watering and consolidation. |
| 56 | S&F machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 60mm thickness M-40 grade with grey cement and pigment. |
| 57 | Dismantling of stone slabs and tiles of any description or thickness in floors/dado etc laid bedded and pointed in any mortar |
| 58 | M & L for 20mm thick Granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window- cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite |
| 59 | Dismantling floor, hearth or wall tiling including cement mortar bedding but not backing), removing serviceable tiles to store and rubbish off the premises |
| 60 | M&L for Vitrified Ceramic tiles 10 mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, in floors laid over & incl 15 mm thick screed in CM 1:6, set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of floor complete as directed by Engineer-in-Charge. |
| 61 | All as per item No. 55 but as in skirting/dado but over 10 mm thick rendering over CM 1:4 |
| 62 | M & L for Non - skid Ceramic tiles 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match laid over & incl 15 mm thick screed bed in CM 1:6 complete all as specified and as directed. |
| 63 | M&L for coloured Glazed ceramic tiles in vertical surfaces 350 x 250 x7 mm/ 450 x 300 x7 mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match over & incl.10 mm thick screed bed in CM 1:4.complete all as specified and as directed. |
| 64 | Dismantaling water tanks and removing to store exc 500 but n. exc 1000 ltrs |
| 65 | Dismantaling water tanks and removing to store exc 250 and n.exc 500 ltrs |
| 66 | S&F rotational moulded polyethylene water storage tanks (cylinderical, vertical with closed top) of 500 Ltrs capacity hoisted and fixed in position incl 20mm bore PVC float valve all as specified and directed in SSR Pt I |
| 67 | S&F rotational moulded polyethylene water storage tanks (cylinderical, vertical with closed top) of 1000 Ltrs capacity hoisted and fixed in position incl 20mm bore PVC float valve all as specified and directed in SSR Pt I |
| 68 | Taking up or down steel water tubing and connections including cleaning for refixing or removing to store 15 mm dia. |
| 69 | All as per item No. 63 here in before, but 20 mm dia . |
| 70 | Supplying and laying of CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified of dia 16mm. |
| 71 | All as per item No. 65 here in before, but 20 mm dia |
| 72 | S&F Stop Valve 15mm bore of standard PTMT any colour high pressure screwed for iron pipe and fixed in repairs (Minimum weight 15mm-90gms) |
| 73 | S&F in repairs fancy type chromium plated 15 mm bore stop valve/angle cock cast copper alloy, screwed down high pressure with crutch or butterfly handle, screwed both ends for iron pipe or for unions complete all as specified and directed. |
| 74 | S&F in repair Wash basins 550x400mm vitreous china (flat back type) any size incl cutting for and pinning in end of brackets for erecting stand but exclusive of fixing of supply and waste pipe but including waste fittings |
| 75 | S&F 600mm x 450mm bevelled edge mirror of selected quality glass, mounted on 6mm thick AC building board or commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers |
| 76 | S&F in repairs PVC valveless, syphonic action type flushing cistern, low level , white, with inlet ball valve, float and handle including brackets 10 litres capacity . |
| 77 | S&F in repairs Vitreous china Squatting pan , 'Orissa pattern, size 580x440 mm white, with integral foot rest excluding flushing cistern and flush pipe including connection to trap, to flushing pipe,WC connector ,'P' trap, etc complete including making good to floor . |
| 78 | S&F in repairs Vitreous China wash down water closet pan (Pedestal pattern) white complete incl seat and cover,WC connector, flush pipe incl all joints complete |
| 79 | S&F in repairs Vitreous China half stall urinals, white complete including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60mm long brass screws, magnum urinal spreader, pointing around urinal back in cement;wast coupling, and Union for discharge pipe. |
| 80 | S & F in repairs chromium plated 15 mm bore Push taps cast copper alloy high pressure screwed for iron/CPVC pipe for urinal complete all as specified and directed. |
| 81 | PVC Connections 15mm size with PTMT nuts of length 600 mm |
| 82 | S&F in PVC (SWR) floor trap 75 mm, plain with CP grating including joining with solvent cement complete |
| 83 | S&F bib taps 15mm bore of standard PTMT any colour high pressure screwed for iron pipe and fixed in repair (Minimum weight 15mm-90gms). |
| 84 | S&F in repair 15mm bore, chromium plated bib taps cast copper alloy with crutch or butterfly handle screwed down for iron/PVC pipe complete all as specified & directed. |
| 85 | S & F in repair pillar taps 15mm bore of standard PTMT any colour ahigh pressure screwed for iron pipe and fixed in repair (Minimum weight 15mm-90gms). |
| 86 | S&F fancy type pillar taps, long neck, 15 mm dia, cast copper alloy, with capstan heads, chromium plated, screwed down high pressure, with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly-nuts, screwed for iron pipe and fixed as in repair complete all as specified. (Cat No 9204 of Prayag or equivalent of Jaquar/Marc) |
| 87 | S&F in repairs tubular towel rail brass chromium plated , 20mm dia, 60cm long between flanges in repairs. |
| 88 | S&F in repair Brass Chromium plated shower roses with or without swivel joints, any size, including fixing to steel pipe or union alongwith arm 225mm and flange. |
| 89 | S&F grating round 100 mm size of PTMT (min weight 25 gms) all as directed by Engineer in Charge. |
| 90 | S&F in repairs Soap dish, vitreous China white/CP, approximate size 160x 160x90mm all as directed by Engineer in Charge. |
| 91 | Demolition of brickwork or stone/ boulder masonry, dressed stone work and precast concrete articles built in cement mortar complete all as specified and as directed. |
| 92 | Pre-cast cement concrete block masonry with solid blocks, exc. 10 cm in width and setting in CM 1:6 , type C1 1:3:6 using 20mm graded crushed stone aggregate complete all as specified and directed. |
| 93 | Taking down cement plastering at any description on brick or stone wall etc including raking out joints hacking for key scrubbing down with water etc and removal of debries and depositing where directed. |
| 94 | M&L for rendering 5 mm thick in CM 1:3 in ceiling finished even and smooth (without using extra cement) |
| 95 | M&L for preparation on newly plastered surface of ceiling for painting and applying 3 mm thick wall care putty on plastered surfaces and applying two coat of oil bound distemper over chalk whiting. |
| 96 | M&L for Rendering 15 mm thick cement plaster on concrete solid block walls in two coats first coat of 10 mm in CM 1:4 & 2nd coat of 5mm in CM 1:4 mixed with integral water proofing compound finished to even & smooth w/o using extra cement. Note :- Integral water proofing liquid will be measured and paid seperately. |
| 97 | Supply only water proofing compound |
| 98 | M & L for preparation of New surfaces walls and applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over treated surfaces |
| 99 | M&L for rendering 10 mm thick in CM 1:6 on concrete solid block wall surface finished even and smooth without using extra cement. |
| 100 | M&L for preparation on newly plastered surface of wall for painting and applying 3 mm thick wall care putty on plastered wall surfaces and applying two coat of oil bound distemper over chalk whiting. |
| 101 | S & F in repairs Ball brass valves 20mm, high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule and fixed. |
| 102 | Dismantling old particle boards/plywood as in shelves boarding, any description, fixed in any position with nails |
| 103 | S/F 18 mm thick single side prelaminated woodgrain solid PVC sheet suitablely fixed in shelves; Partitions and shelves of built-in cupboards, almirahs, book cases, toilet boxes, racks, pelmets and similar work with all fittings as per direction and specifications. |
| 104 | M&L for complete removal of existing treatment and Preparing old plastered wall surfaces and applying two coat of oil bound distemper over alkali resistant primer, on plastered surfaces, preparatory to distempering, after applying 3mm thick wall care putty on wall. |
| 105 | M & L & complete removal of existing treatment for old surface of walls incl sealing the cracks and applying Two coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over treated surfaces |
| 106 | M&L for preparation of old painted wooden surfaces of any descripton over 10cm width or girth and applying one coat of synthetic enamel paint First quality all as specified and directed . |
| 107 | M&Lfor preparation of old painted steel surfaces of any description over 10cm width or girth and applying one coat of synthetic enamel paint First Quality all as directed and specifried |
| 108 | M&Lfor preparation of old painted steel surfaces of any description over 10cm width or girth and applying one coat of aluminium paint First quality all as directed and specifried |
| 109 | M&L for preparation of steel surface and applying one coat of red oxide zinc chrome primer and two coats of Epoxy anticorrosive paint over 10 cm width or girth. |
| 110 | M/L for writing letters/Bldg Nos or figures(Block, Roman or Indian) on wall 10cm height using synthetic enamel paint white or circular /black painted, black back ground all as specified and directred by Engg in charge |
| 111 | Dismantling/Taking out existing hessain base felt of any other existing water proofing treatment from roof including cement plaster and exposing the top surface of RCC slab including removing dust, vegetation, shrubs , small plant, dirt and washing the roof and removing the dismantled debris to a distance exceeding 200 m but not exceeding 3000m spread and levelled as directed by Engr-in -charge. |
| 112 | Providing 10mm thick plaster in CM (1:3) mixed with 1% integral water proofing compound over roof top surface incl filling all cracks by forming groove of 5mm x 5mm finished to even & smooth w/o using extra cement. Note :- Integral water proofing compound will be measured and paid seperately |
| 113 | Demolition of un-reinforced Cement Concrete of any description and in any position not otherwise specifically provided for. |
| 114 | M&L for 25 mm thick Cement concrete type B0, 1:2:4 (using 12.5 mm graded granite stone aggregate) in padding on roof for maintaining proper slope to avoid waterlogging all as specified and directed. |
| 115 | M&L for priming surfaces and applying normal treatment (for moderate conditions) using glass fibre base bitumen felt grade 2 complete all as specified and directed. |
| 116 | M&L for APP based polymeric membrane minimum weighing 3Kg/sqm and minimum 3mm thick reinforced with polyster non wove fabric (wt. not less than 150 gms/sqm) land on primed surface by forced application completed all as specified. |
| 117 | Providing and applying fiber reinforcement Elastomeric liquid applied waterproofing membrane ,formulated with PU hybrid polymers and reinforcing acrylic fibers and can bear upto 10 bar hydrostatic pressure by using Asian Paints SmartCare Damp proof Ultra having Sun Reflective Index (SRI) of 106 .59 on top concrete roof in three coats @10.8 liter/10 sqm. One coat of self –priming of elastomeric water proofing liquid (dilution with water in ratio 3:1) and second coat of undiluted elastomeric waterproofing liquid followed by 3rd and final coat of undiluted elastomeric waterproofing liquid (dry film thickness of complete application/system not less than 600 micron ) with waterproofing warranty 10 years . CONTD TO 112.01 |
| 118 | Prior to all this activity surface preparation to be done by pressure washer to remove Dust, Algae ,fungus , oil grease ,etc and crack filling by smart care textured crack filler up to 10mm wherever required and bigger crcak should be filled with polymer modified cement . On tile mosaic surface use smartcare terrace tile primer for better adhesion . The item rate is inclusive of all material with wastage , labor, tools tackles, Consumable . scaffolding etc. Make : Asian Paints SmartcareNote: The application of paint to be done by the authorized applicator of Asian paints or equivalent make and contractor shall submit a written guarantee with the authorized dealer of 10 years of any type peeling, flaking, growth of fungus, seepage water through the pant applied area of any other damaged to the paint. Also the dealer shall appoint a person to inspect and validate the application of the system in stage wise manner. |
| 119 | M&L for SIKA Shield W-1 (Red or Grey powder) polymer modified cementitious adhesive (bonding slurry) over prepared concrete surface with mixing ratio of 8.75 ltrs of clean water per 30 Kg bag of SIKA Shield W-1 with consumption of 2-3 Kg/Sqm. complete all as specified and directed by Engr-in-charge. |
| 120 | M&L for SIKA Shield W-159, 1.5 mm thick (with 10% variation) double sided modified bitumen water proofing membrane consisting of cross laminated PE film and two modified bitumen layers covered with transparent release liners complete all as specified and directed by Engr-in-charge. |
| 121 | Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and as directed. |
| 122 | Dismantling fencing wire mesh any type complete all as specified and as directed. |
| 123 | Dismantling posts or strusts (steel) any section, embedded in concrete, brickwork masnory etc., including taking out embedded portion and making good the disturbed ground complete all as specified and as directed. |
| 124 | Excavating in post holes (or similar holes) each n.exc 0.5 cum, getting out returning filling in and ramming earth or broken rubble mixing with earth around, in layers n.exc 25 cm, watering and removing surplus soil to a distance n.exc 50m and making good surface in soft/ disintegrated rock. complete all as specified and directed. |
| 125 | Demolition of cement concrete (unreinforced) in ground floors and pavings not exceeding 15cm thickness below or above ground level complete all as specified and as directed. |
| 126 | M&L Plain cement concrete (1:4:8), type D-2 using 40mm graded stone aggregate as in foundations and mass concrete complete all as specified and directed. |
| 127 | S&F Hand rails, half round or other stock section or core for wooden hand-rail, straight portion, drilled & countershunk for balusters running bars, for doors, balusters, nosing to steps including embeding in concrete & screwing etc. wind ties for roof including securing bolts.posts & struts in fencing including ctting tops to shape as directed, drilling holes, notching for wire mesh wire, etc: flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc & similar work conforming to Fe 290-0 Grade E-165 complete all as specified and directed. |
| 128 | supplying of MS galvanised Chain link fencing any size including line wires, all as specified and as directed. |
| 129 | Fixing only chain link fencing including line wires, any mesh, size and type to any type of standards, rails, straining bolts, etc. complete all as specified and directed. |
| 130 | S&F mild steel round bars of any dia and over cut to length, bent to shape required, including cranking, bending etc (Fe-410-W Gde E-250 quqlity-A ) complete all as specified and directed. |
| 131 | M&L mild steel in flat iron or square bars in available length supporting steel angle (Fe-410-W (gde. E-250) quality-A all as specified and as directed. |
| 132 | S&F plates (plain or chequred) channels, square cut or notched (ordinary and counter sunk) forming holes, with riveted, bolted or welded attachment . Fe 410-W (Grade-E- 250) quality-A complete all as specified and directed. |
| 133 | Supply and fix in repairs Galvanised, 2 strand, steel barbed wire 2.24mm dia barbed with 2mm dia barbs at 75mm spacing and straining and fixing to any tupe of standard rails straining bolts, including, securing or tying at crossings with and provision of galvanized mild steel wire, staples or steel pins etc, all as specified and as directed. |
| 134 | M&L Prepearing new steel surfaces of any description over 10 cm in width or girth and applying two coats of synthetic enamel paint over one coat of Red oxide, zinc chrome primer complete all as specified and directed. |
| 135 | Dismantling of existing steel rolling shutters including top covers for repairs & refixing in the same opening after repairs including greasing the spring, guide channel shafts, bearing, bolts, washers, including repairing defective laths spring bearing , hood cover, guide channel suspension shafts etc complete as directed by Engr-in-Charge for rolling shutter of clear area upto 7 Sqm each Note:- Necessary spares will be measured & paid seperately. |
| 136 | All as per item No.129 above but rolling shuters area exc 7.00 sqm but not exc 10 sqm |
| 137 | All as per item No.130 above but rolling shuters area exc 10 sqm but not exc 20 sqm |
| 138 | S & F Ball bearing for rolling shutter. |
| 139 | S & F Steel rolling shutters of 1.25 mm thickness laths without ball bearing as specified including top cover, anchoring rod, hasp and staple and one shop coat of primer erected in position as indicated complete push & pull or manual type. |
| 140 | S & F Steel rolling shutters, with out ball bearing, as specified including top cover, anchoring rod, hasp and staple and one shop coat of primer; erected in position as indicated, complete: with bevel gear box and crank handle 1.25mm thick. |
| 141 | E/M PORTION |
| 142 | Taking down carefully any type of copper/aluminium point wiring (light,fan, socket or power) complete including conduits/casing caping with fittings such as switches,ceiling roses, pendents,regulators,bells, sockets, tube light fittings etc, removing the materials/debris and making good the disturbed surface of walls & floors etc to match with the original existing finish complete all as specified and as directed |
| 143 | M & L for one point wiring with PVC insulated un-sheathed cable with stranded copper conductor FR-LS conforming to IS : 694 of size 1.5 Sq mm single core, including one No. 1.5 Sq mm single core PVC insulated un-sheathed copper cable FR-LS as continuous earth wire drawn in and including PVC Casing & Caping double lock/conduit pipe type of as required width (not less than 20 mm in width) ISI marked medium grade white colour with all accessories of same grade fixed on wall/ceiling including terminated in to Cast iron/pressed steel terminal box 60mm deep of required size made out of 2 mm thick MS sheet duly painted both sides with 3 mm thick plastic laminated sheet top cover fixed with brass screw & cup washers and including provision of modular metal flush box, modular cover plate with frame top cover for mounting switches, fan regulators etc for one light point controlled by one 5 Amp switch one way complete all as specified and as directed |
| 144 | All as per item No. 137.00 here in before, but for one fan/exhaust fan point controlled by one 5 Amp all as specified and as directed. |
| 145 | All as per item No. 137.00 here in before, but for one 3/5 Pin, 5 Amp Switch socket out let on the independent board complete all as specified and as directed |
| 146 | All as per item No 137.00 above, but with 2.5 sqmm for One 3 pin 16 amps socket outlet point controlled by one 16 amps switch on the ndependent board complete all as specified and as directed. |
| 147 | Taking down unserviceable any type of copper/aluminium sub main wiring of any type/size/core/ type complete including conduits/casing caping etc, removing the materials/debris and making good the disturbed surfaces of walls, floors and ceilings etc to match with the original existing finish complete all as specified and as directed. |
| 148 | M & L for sub main wiring with two runs of single core 1.5 Sqm, FRLS Copper conductor PVC insulated unsheathed cable as per IS 694-1990 (third revision) drawn through & including non- metallic rigid PVC casing caping (double interlock type) of suitable width medium duty with all accessories such as Tees, elbows, junction boxes etc, as required fixed on wall along with one run of 1.5 Sqmm single core PVC FRLS insulated unsheathed copper conductor cable as continuous earth wire and connecting to existing main switch board/ distribution board and testing on completion etc complete all as directed. (Note :- Two runs of cable, one run of earth continuity conductor and one run of PVC casing caping/conduit shall be measred as one unit) |
| 149 | All as per item No 142.00 here in before, but two run of single core 4 sqmm and one run of 4 sqmm cables as earth continuity conductor all as directed. |
| 150 | S & F in repairs Switch Piano flush button single pole one way 5 A , 240 V complete all as specified and as directed |
| 151 | S & F in repairs modular Switch single pole one way 6 A, 240 V complete all as specified and as directed |
| 152 | S & F in repairs modular Switch single pole one way 16 A, 240 V complete all as specified and as directed |
| 153 | S & F in repairs Switch Socket Combination 5A/16A, 5 in 1, 3 pin, 240 volts complete all as specified and as directed |
| 154 | S & F in repairs Modular Socket outlet 5A/16A, 5 in 1, 3 pin, flush type universal, 240 voltscomplete all as specified and as directed |
| 155 | S & F in repairs Ceiling rose, surface bakelite, 65 x 50 mm two/ three terminals 240 volts complete all as specified and as directed |
| 156 | S&F in repairs stepped type electronic fan regulator flush type as per exisitng model on the existing board all as directed. |
| 157 | S&F in repairs stepped Modular electronic fan regulator on the existing board all as directed. |
| 158 | S & F in repairs modular flush metal box with inner & outer sheet fixed in 60 mm deep of suitable size for 1/2 module fixed with screw for mounting modular switches, Sockets, fan regulators etc for existing elect arrangements and connected to the existing elect wires, making good the distrubed area with cement work and paints as same existing backgound all as directed.(Note : New modular switches, sockets & fan regulators will be measured and paid separely) |
| 159 | All as per item No. 152.00 here in before, but Size of the box suitable for 3 module |
| 160 | All as per item No. 152.00 here in before, but Size of the box suitable for 4 module |
| 161 | All as per item No. 152.00 here in before, but Size of the box suitable for 6 module |
| 162 | S & F in repairs White inner, outer cover plate Modular type with frame, 2 module |
| 163 | Diito all as per item No 156.00 here in before but 3 module |
| 164 | Diito all as per item No 156.00 here in before but 4 module |
| 165 | Diito all as per item No 156.00 here in before but 6 module Please Enable Macros to View BoQ information |
| 166 | Diito all as per item No 156.00 here in before but 6 module Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Oct 14, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedNov 05, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 7 daysNov 12, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 14 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender