Defence Statutory Bodies & Commissions/Committees Closing in 3 days TDR #58041395

Tender For Special Repairs To Bldg No Np-80 Under Ge (A) Ahmedabad Cantt

Issued by Statutory Bodies & Commissions/Committees · Ahmedabad, Gujarat
Tender Value
14.55 Lakhs
Estimated cost
Bid Submission
02 Nov 2026
3 days left
EMD
29500
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Ahmedabad → Gujarat
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender For Special Repairs To Bldg No Np-80 Under Ge (A) Ahmedabad Cantt

BOQ

Name of Work:- SPECIAL REPAIRS TO BLDG NO NP-80 UNDER GE (A) AHMEDABAD CANTT
Sl. No. Item Description
1Item Rate BoQ BoQ_Ver3.0 Item Rate Normal INR Only INR Select, Excess (+), Less (-) Less (-) Tender Inviting Authority: GE (ARMY) AHMEDABAD NAME OF WORK : SPECIAL REPAIRS TO BLDG NO NP-80 UNDER GE (A) AHMEDABAD CANTT CONTRACT AGREEMENT: GE (A)/ABD/ OF 2026-2027 Bidder Name : PRICE SCHEDULE(This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only ) NUMBER # TEXT # TEXT # NUMBER # TEXT # NUMBER NUMBER TEXT TEXT # NUMBER # TEXT# TEXT # NUMBER # NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER # NUMBER # TEXT TEXT NUMBER # NUMBER # DATE NUMBER # NUMBER # TEXT # Sl.No. Description of Item of Work Item Code / Make Quantity Unit Estimated Rate Addition / Deduction Addition / Deduction Values Currency Convertion against each Item Quoted Currency in INR / Other Currency BASIC RATE In Figures To be entered by the Bidder Rs. P Excise Duty VAT Freight Charges ( Unloading & Stacking) Any Other Taxes/Duties/Levies Other Taxes 2 IIIrd Party i.e DGS&D / RITES etc Inspection Charges @0.34%+Service Tax Less for Cenvat Credit,if any respect of Supplies Under full Excise Duty Category TOTAL AMOUNT TOTAL AMOUNT With Taxes TOTAL AMOUNT (in Words)
2Demolition of brick work built in cement mortar or cement lime mortar including all quoins, arches etc complete all as specified and as directed.
3M&L for brick work with sub class 'B' bricksstraight or curved on plan exc. 6.00m meanradius built in cement mortor 1:6 complete all as specified and as directed.
4Demolition of reinforced cement concrete in ground floors and pavings n.exc 15 cm thick above or below ground level complete all as specified and as directed.
5Demolition of cement concrete (unreinforced) any description and in any position (Below or above ground leverl) not otherwise specifically provided for complete all as specified and as directed.
6M&L 75mm thick PCC (1:3:6) type C2 as in plinth protection/footpath using 40mm graded stone aggregate finishing cement concrete surface even & smooth without using extra cement including impression and glass strip or bitumen filling in two panel etc complete all as specified and as directed.
7Taking down cement plaster and raking out joints, hacking for key,scrubbing down with water built in cement mortar complete all as specified and as directed.
8M&L for rendering 15mm thick in CM 1:4 on fair faces of brick work or concrete surfaces mixed with integral water proofing compound finished even & smooth without using extra cement. Note : WPC shall be measured & paid seperately.
9Supply only integral water profing compound ISI marked complete all as specified and as directed.
10M&L for rendering 15mm thick in CM 1:6 on fair faces of brick work or concrete surfaces finished even and smooth without using extra cemen complete all as specified and as directed.
11M&L 3mm thick wall care putty on wall including complete removal of existing treatment all as specified and directed by Engr-in-charge
12Dismantling floor hearth or wall tiling including cement mortar bedding but not backing complete all as specified and as directed.
13M & L for Joint free Non - skid Ceramic coloured tiles 7 to 8 mm thick area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match incl and over screed bed or beeding layers of mortar 15mm thick in CM 1:6 in floors, complete all as specified and directed. complete all as specified and directed
14All as per item No 12 above but on vertical surfaces such as skirtings, dados and risers to steps etc incl rendering 10mm thick on of brick work or concrete surfaces in cement mortar 1:4 complete all as specified and as directed.
15Dismantling asbestos cement/CGI (corrugated, semicorrugated, etc.) sheets in roof coverings complete all as specified and as directed.
16Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and as directed.
17M&L for MS work as in roof trusses (framed) trussed, purlin, post, rafters including distant pieces, claeats includinjg cutting and welding required confirming to grade Fe-410-W(Gde-E-250) quality complete all as specified and as directed.
18Fixing only MS work as in roof trusses (framed) trussed, purlin, post, rafters including distant pieces, claeats includinjg cutting and welding required confirming to grade Fe-410-W(Gde-E-250) quality complete all as specified and as directed.
19S & F Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws all as specified and as directed.
20S&F Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in ridges, valley gutters fixed with self tapping screws all as specified and as directed.
21Taking down chowkats or frame with shutters (without taking off shutters from the frame) exc 1.5 sqm and n exc 4.0 sqm each complete all as specified and directed.
22All as per item 20 above but n.exceeding 1.5Sqm each complete all as specified and as directed.
23S&F aluminium powder coated framed windows, any pattern, fixed/side hung/sliding Three track using powder coated aluminium sections or approved make, with or without sash bars, suitable for 4.00 mm thick glazing and stainless steel alloy wire cloth, 0.36 mm nominal dia of wire and average width of aperture 1.40 mm wire guaze, including necessary rubber packing, joining cleats, glazing clips, aluminium snap beading, handles, locking arrangements, frame of window should be of 1.5 mm thick section & shutter sec like handle/interlocking/top/bottom should be of 1.2 mm thick etc , complete all as specified and as directed Note :Rates include all glazing/aluminium wire cloth, rubber packing, joining, cleats, glazing clips, aluminium snap beading, locking arrangements, handle etc complete all as specified and directed. Make Jindal
24S&F 30 mm thick Flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides
25S & F 200 mm Aluminium, anodised, barrel tower bolts of extruded section and fixed
26S & F 300 mm Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded section or cast-aluminium alloy and fixed
27Supply & Fixing 150 mm Aluminium handles, cast type, anodised complete all as specified and as directed.
28S&F door stopper of aluminium alloy body and tongue anodised with rubber shoe fixed to wooden shutters with screws complete all as specified and as directed.
29Supplying and fixing of Solid PVC Door Frame of size 50mm x 47 mm made out of 5mm plain colour PVC sheet reinforced with M.S. Square tube, suppling & fixing in opening as per specification & drawing
30Dismantling wall and ceiling boards any description, any thickness, including cover fillets complete all as specified and as directed.
31S&F Tee grid suspension system of size 600 mm x 600 mm type-1 made out of roll framed hot dipped galvanised steel zince coated of not less than 120 gm/Sqm, main runner 0.3 mm thick of section 24 mm x 33 mm crross runner 0.30 mm thick of section 24 mm x 25 mm, wall angle shall be 0.63 mm thick of section 24 mm x 24 mm grid shall be suspended by 4 mm dia adjustable quick fit hanger rod, system exposed portion shall be pre painted polyester coated in off whitee/white in colour complete with material, fixing, jointing etc., with Coloured textured designer ceiling board (Everest)/Asbestos Cement white fiber Board 4mm thick of size 595 x 595 mm fixing with screws/clips complete all as per manufacturers instructions and direction.
32M&L for applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces complete all as specified and directed.
33M&L for preparation of new plastered surfaces of wall and applying two coats of oil bound distemper over a coat of primer all as specified and directed .
34M&L for Non - skid Ceramic coloured tiles 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match incl and over screed bed or beeding layers of mortar 15mm thick in CM 1:6 in floors, complete all as specified and directed. complete all as specified and directed
35M & L for coloured glazed ceramic tiles of size 450X 350X 7mm thick on vertical surfaces such as skirting, dados etc, set and jointed in neat cement slurry and pointed in coloured cement to match.
36supply and fixing factory made solid panel PVC door shutter 30 mm thick (style)consisting of frame made out of MS tubes for top and bottom rail. MS frame shall be covered with heat moulded plain colour PVC 'C' channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail ; panelling of plain colour PVC sheet to be fitted in the M.S frame welded/sealed to the stiles & rails with suitable PVC sheet beading and joined together with solvent cement as per specification & drawing .
37S&F Butt hinges, medium weight coldrolled mild steel and fixed 100mm size complete all as specified and as directed.
38S & F 125 mm Aluminium, anodised, barrel tower bolts of extruded section and fixed complete all as specified and as directed.
39Supply & Fixing 125 mm Aluminium handles, cast type, anodised complete all as specified and as directed.
40Taking up or down GI tubing 15/20mm bore pipe and connection including cleaning for refixing or removal from site as directed
41Cutting chases, pinning in, making good to facing where reqd and pointing in CM 1:3 to ends of edges of landing etc and cutting chases for concealed water tubing and making good cutting n.exc 10 cm girth.
42Supplying and laying of 20 mm bore CPVC pipes SDR 11 and plain CPVC SDR 11 fittings in trenches, fixing on walls/ceiling or laying in floors complete all as specified
43Dismantling pf PVC water Tank of any descriptionand at any position exc 250 ltr and n.exc 500 ltr capacity complete all as specified and as directed.
44S & F in repairs Rotational moulded polyethylene (cylindrical vertical with closed top) 1000 ltrs capacity hoisted and fixed in position including inlet, outlet and 20mm bore PTMT float/ball valve complete all as specified and as directed.
45S&F in repair 20mm dia Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and as directed.
46S & F in repairs viterous china wash down water close (Pedestral pattern) EWC white incl plastic water closet seat cover and mild steels chromium plated on aluminium hinging device and connecting to 'P' or 'S' incl connecting flush pipe with flushing rim all as specified and directed.
47S&F 10 ltrs capacity PVC valve less, syphonic action type flusing cistern, low level white with inlet ball valve float and handle including brackets fixed in repairs complete all as specified and directed.
48S&F in repairs vitreous china wash basin, white, flat back, size 550x400m excluding taps, waste , chain & plug & porcelain stopper including brackets incl cutting for pinning in ends of bracketes or erecting stand and fixing and supply and waste pipe complete all as specified and directed
49S&F PVC connection 15mm dia and 45cm long with two Nos of brass checknuts and washers complete all as specified and as directed.
50S & F in repairs stop valvew/Angle valves fancy type chromium palted with long shank and cup screwed for iron pipe of 15 mm bore, screwed both ends includinf necdessary fittings such as sockets ofr pipes or for union complete all as specified and as directed
51S & F in repairs Bib taps fancy type chronium plated with crutch or butterfly handle screwed down screwed for galvanised iron pipe or for brass ferrule and fixed complete for 15 mm bore complete all as specified and as directed.
52S & F in repairs pillar tap with capstan heads chronium palted screwed down high pressure with or without letter 'Hot' or 'Cold' with long screwed shanks and flynuts screwed for galvanised iron pipe and fixed complete for 15 mm bore complete all as specified and as directed.
53S&F in repairs grating doom 125mm dia with waste hole of PTMT (Min wt 40 gms) complete all as specified and as directed.
54S & F in repair 600x450mm mirror of selected quality glass, mounted on 6mm thick AC building board or commercial plywood including PVC frame fixed to wooden plugs with CP brass screws & cup washers.
55S & F PTMT shelf with and including chromium plated brass screws and wooden/plastic cleats (Minimum weight 300 gms) complete all as specified and as directed.
56S&F 600mm long Tubular towel rail brassl chromium plated 20mm dia, D type, with two plugs (Gutties) MS screwscomplete all as specified and directed by Engr-in-charge.
57S&F in repair 15mm dia stop valves, fancy type chromium plated with long shank and cup (conncelaed type) cast copper aolly screwed down high pressure, screwed both ends for iron pipe or for unions.
58S&F in repairs brass CP shower rose 125 mm size with or without swivel joint and fixing to steel pipe complete all as specified and as directed.
59M&L in repair for water proofing treatment to non accessible RCC roofs by providing 10mm thick screed in CM 1:3 mixed with & including water proofing compound @ 3% by weight of cement & applying one coat of bituminous primer @ 0.30 kg/sqm & laying APP based polymer modified membrane with polyster non woven reinforced of weight not less than 3 kg/sqm 3mm thick with polythene finished sealing with side over laps of 75mm & 100mm laps at the ends of membrane by torch application method & applying two coats of aluminium paint as per the makes approved by the Engr-in-Charge. incl taking down old treament
60Dismantaling of AC/ PVC drain pipes jointed in cement mortar and taking out from trenches or walls of any bore including fittings 100 mm dia.
61Dismantaling of AC/ PVC drain pipes jointed in cement mortar and taking out from trenches or walls of any bore including fittings 75 mm dia.
62S&F for PVC (SWR) floor trap 100/75mm dia of outlet, plain with grating including jointing with solvent cement fixed in repairs.
63S & F PVC (SWR) pipes single socketed in any length with rubber ring joints laid under floors bore of 110 mm including bends, complete all as specified and as directed.
64S & F PVC (SWR) pipes single socketed in any length with rubber ring joints laid under floors .of pipe 75 mm including bends, complete all as specified and as directed..
65Taking down copper/aluminium point wiring ( light, socket or power) complete,incl fixtures and fittings like switches, ceiling rose, pendant, regulator, sockets, light fitting ( Mirror light,Bulk head,LED Panel 2''x2'',security light,wall fitting,down light, Flood light,post top lantern) etc. removing materials for taking credit and making good disturbed surfaces of walls, floors, etc with cement plaster, putty and paint to match with the existing surface complete all as specified and directed.
66M&L for Point wiring with 1.5 Sqmm FRLS insulated, unsheathed, multistranded, 1100 Volts grade copper conductor cable single core along with one run of 1.5 Sqmm FRLS insulated copper conductor cable green in colour for continuous earthing drawn through and including medium grade rigid PVC conduit and its all accessories/junction boxes/ inspection covers etc of suitable size but not less than 20mm(OD), concealed conduit wiring on wall/ floor etc including provision of branded pressed galvanised steel terminal box, 60 mm deep with earth dolly of suitable size concealed in wall and modular metal flush box covered with modular frame plate with cover of any size as per site requirement for mounting modular switches, modular sockets, modular fan regulator, etc. complete all as specified and directed by Engineer-in-Charge for the following points:-One light / ceiling fan / exhaust fan / call bell point controlled by one switch
67M&L for Point wiring with 1.5 Sqmm FRLS insulated, unsheathed, multistranded, 1100 Volts grade copper conductor cable single core along with one run of 1.5 Sqmm FRLS insulated copper conductor cable green in colour for continuous earthing drawn through and including medium grade rigid PVC conduit and its all accessories/junction boxes/ inspection covers etc of suitable size but not less than 20mm(OD), concealed conduit wiring on wall/ floor etc including provision of branded pressed galvanised steel terminal box, 60 mm deep with earth dolly of suitable size concealed in wall and modular metal flush box covered with modular frame plate with cover of any size as per site requirement for mounting modular switches, modular sockets, modular fan regulator, etc. complete all as specified and directed by Engineer-in-Charge for the following points:-One 6A socket point controlled by one switch on independent board
68M&L for Point wiring with 1.5 Sqmm FRLS insulated, unsheathed, multistranded, 1100 Volts grade copper conductor cable single core along with one run of 1.5 Sqmm FRLS insulated copper conductor cable green in colour for continuous earthing drawn through and including medium grade rigid PVC conduit and its all accessories/junction boxes/ inspection covers etc of suitable size but not less than 20mm(OD), concealed conduit wiring on wall/ floor etc including provision of branded pressed galvanised steel terminal box, 60 mm deep with earth dolly of suitable size concealed in wall and modular metal flush box covered with modular frame plate with cover of any size as per site requirement for mounting modular switches, modular sockets, modular fan regulator, etc. complete all as specified and directed by Engineer-in-Charge for the following points:-One 6A socket point controlled by one switch on same board
69All as per item No. 65.00 here-in-before but one 16A socket point controlled by one 16A switch on independent board with 2.5 sqmm wires.
70Taking down carefully aluminum or copper submain wiring with PVC surface conduit or casing caping and making good disturbed surfaces complete all as specified and as directed.
71M&L for sub main wiring along with earth wire with FRLS insulated copper conductor, single core cable drawn through and including medium grade rigid PVC conduit and its all accessories/junction boxes/ inspection covers etc of suitable size but not less than 25mm concealed in wall/ floor etc including taking down existing unserviceable sub main wiring of any description complete all as specified and directed for 2runs x 4 sqmm(Ph & N) + 1run x 4 sqmm(earth wire) (Note: Three runs of copper cable and one run of PVC conduit shall be measured as one unit length)
72M&L for sub main wiring along with earth wire with FRLS insulated copper conductor, single core cable drawn through and including medium grade rigid PVC conduit and its all accessories/junction boxes/ inspection covers etc of suitable size but not less than 25mm concealed in wall/ floor etc including taking down existing unserviceable sub main wiring of any description complete all as specified and directed for 2runs x 6 sqmm(Ph & N) + 1run x 6 sqmm(earth wire) (Note: Three runs of copper cable and one run of PVC conduit shall be measured as one unit length)
73Notes for item No. 65.00 to 71-00: (i) Quoted rate shall deemed to include the cost of cutting chases on wall/floor for concealed conduit wiring and making good with cement plaster, putty and paint to match with the existing surface.(ii) If any beam / column / Rock wall is encountered while cutting chases, that particular portion may be provided with PVC casing & capping or surface conduit for drawing cables and surface PVC gang box fully enclosed type for mounting switches, sockets & regulators etc to avoid any damage to the structure. (iii) No cutting shall be done on ceiling for laying PVC conduit for ceiling fan point wiring. Surface conduit or PVC casing capping may be used in that portion.
74Supply and fix in replacement of Modular switch 1 way 6A, 1 module 240V, 50Hz complete all as approved.
75Supply and fix in replacement of Modular switch 1 way 16A, 1 module 240V, 50Hz complete all as approved.
76Supply and fix in replacement of Modular Socket, 6A - 2/3 pin combined 2 module 240V, 50Hz complete all as specifed and directed.
77Supply and fix in replacement of Modular Socket 6A/16A - 2/3 pin combined 2 module 240V, 50Hz complete all as specified and directed.
78Supply and fix in replacement of modular ceiling rose 6 Amps, 3 plate, 240V, 50Hz complete all as specified and directed.
79Supply and fix in replacement of Modular BLDC fan regulator step type in 5 steps, 240V, 50Hz complete all as specfied and directed.
80Supply and fix in replacement of old unserviceable LED tube light fitting Integral slim LED batten 20 watts with polycarbonate housing and diffuser internally prewired complete with all accessories and including connecting up with pvc insulated and pvc sheathed twisted three core flexible copper wire of 0.5sqmm from ceiling rose to connector of fitting complete all as specified.
81Supply and fix in replacement of recessed mounted LED panel light 2'x2' size, 36 watts, full white / warm white as per site requirement with electronic driver in CRCA sheet steel body with polycarbonate diffuser suitable for POP / Amstrong / grid false ceiling complete with all fixing accessories including making electrical connection with pvc insulated and pvc sheathed twisted two core wire of suitable size complete all as specified.
82Taking down existing old ceiling / exhaust fan of any size carefully, sealing cable end, dismantling blades and removing fan and blades and deposited to AGE E/M store yard complete all as specified and directed
83S&F ceiling fans complete with blades, down rods, and accessories, 230V, 1200 mm sweep, min air delivery 210 CFM with service value 6.00 BEE, Five star rated with brushless direct current motor (BLDC) complete all as specified and directed.
84Supply and fix in replacement of ventilating / PVC exhaust fans fancy square type 250mm sweep with plastic fiber body heavy duty 230 Volt AC, single phase complete with plastic louvers and including making suitable size of holes in wall for fixing the fan including making electrical connection with ceiling rose including taking down existing unserviceable ventilating fan of any description complete all as specified and directed.
85Supply & fix Wall fans 400mm sweep with plastic fiber body, and web mesh guard, 230V AC, single phase, oscillating type complete and fixing the fan to wall including making electrical connection with ceiling rose including taking down existing unserviceable wall fan of any description complete all as specified and directed.
86Supply and fix in replacement of LED street/security light fitting 35 watts with high efficiency long life LEDs with In-built electronic driver complete housed in pressure die-cast aluminium housing covered with polycarbonate cover with IP66 degree of protection including GI pipe bracket made up of 40mm dia medium grade GI pipe of length 1.00m bent to required shape and fixing on walls with suitable MS clamps(02Nos) made up of 25mmx4mm MS flat, nuts, bolts and washers and provision of 3 core pvc insulated and pvc sheathed twisted three core flexible copper wire of 0.5sqmm from ceiling rose to connector of fitting complete all as specified.
87Supply and fix in replacement of modular MCB protected plug and socket board in sheet steel enclosure with 25 Amp rated mini MCB and 25 Amp rated 3 pin plug, 240 V, 50 Hz complete including cutting the wall surfaces for flush mounting of socket board including taking down existing unserviceable plug & socket board of any description and making good with cement plaster, putty and paint to match with the existing surface all as specified.
88Supply and fix in replacement of MCCB / MCB distribution board, Vertical TPN, 4 way, 415 V, 3 phase, AC with MCCB as incomer and MCBs as outgoing in sheet steel powder painted enclosure double door type with minimum IP 43 degree of protection with built in copper bus bar, neutral link and earth link complete including cutting the wall surfaces for flush mounting of DB and making good with cement plaster, putty and paint to match with the existing surface including taking down existing unserviceable MCB DB of any description complete all as specified and directed. Note: MCCB / MCBs shall be measured and paid separately.
89Supply and fix MCB distribution board, SPN, 8 way, 230 V, 1 phase, AC in sheet steel powder painted enclosure double door type with minimum IP 43 degree of protection with built in copper bus bar, neutral link and earth link complete including cutting the wall surfaces for flush mounting of DB and making good with cement plaster, putty and paint to match with the existing surface all as specified and directed. Note: MCBs shall be measured and paid separately.
90Supply and fix in replacement of MCCB 160A, 16 KA, 4 Pole, 415 V, 50 Hz with fixed thermal magnetic release fixed in Vertical TPN complete all as specified and directed.
91Supply and fix in replacement of MCB 63A, 10 KA, SPN, 'C' curve, 240 V, 50 Hz including taking down existing unserviceable MCB of any description complete all as specified and directed.
92Supply and fix in replacement of MCB 6 - 32A, 10 KA, single Pole, 'C' curve, 240 V, 50 Hz including taking down existing unserviceable MCB of any description complete all as specified and directed.
93Supply, Installed & fix maintenance free earthing copper bonded steel earth rod of 10 feet long having diameter of 17.2mm with copper bonding thickness of 250 micron with universal clamp made of SS earth enhancing compound shall be of 30kg/pit(resistivity is less than 0.12 Ohm meter).The bove arrangements shall be provided with heavy duty earth poly plastic pit cover of 4000 kg load bearing capacity (Size:270 x 40 200mm) complete all as specified and directed.
94Taking up of old unsv cable of any size and make complete all as specified and directed.
95Supply, laying and testing of LT UG cable, XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of 35 sqmm 4 core. complete all as specified and directed.Note: Earth work ( Excavation, Returning & refilling and removal), cable protection HDPE pipe, GI protection pipe shall be measured and paid for seperately under respective item of Sch 'A'.
96Material and labour for Double wall corrugated HDPE pipe PN10, ISI marked of outer dia 50mm, inner dia 38mm with smooth internal and profiled external surface, non-pressure type, laid in trenches/floors/duct or fixed on walls /pole including all connections, accessories like socket, couplers, bends, etc for protection of LT cable XLPE grade 1100 volts complete all as specified and directed.
97M & L for Horizontal Boring of holes under road, pavement, hard standing by trenchless technology using GI Pipe of required dia and necessary machine suitable for 0.4 mpa working pressure complete all as specified and directed. Note :- HDPE pipe will be measeured and paid saperately under respected item.
98M&L for drilling/boring and tapping on existing CI/GI pipe pipe 40mm to 150mm dia size for branch connections of 15mm to 50mm dia by fixing of MS clamp of size 50x40mm cut to length and bent to shape, drilled and welded with GI socket of suitable size including rubber packing, nut, bolt and washer etc. and testing complete all as specified and directed.
99S&F 20 mm Gun-metal, globe or gate valves of bore of following sizes, with iron wheel head, screwed both ends for CPVC pipe and fixed complete all as specified and directed.
100Excavation in trenches not exc 1.5 m wide and not exc 1.5 m depth for laying of GI Pipe and getting out in any type of soil complete all as specified and directed.
101Returning, filling in, including leveling, watering and well ramming in layers not exc 25 cm complete all as specified and directed.
102Removing excavated material not exc 50m and depositing where directed at a level not exc 1.5m above the starting point complete all as specified and directed. Total in Figures 0.0 23 INR Zero Only 4.0 Construction of chamber for 100mm sluice plates item5 10.0 Nos Quoted Rate in Figures Select 0.0 0.0 Zero Only Quoted Rate in Words INR Zero Only Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 58041395
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 14.55 Lakhs
LAST DATE 02-11-2026
Authority
Authority Name Military Engineer Services
Work Description Tender For Special Repairs To Bldg No Np-80 Under Ge (A) Ahmedabad Cantt
Basic Detail
Tender No 8381/E8
Bidding Type Tender
Location
City Ahmedabad
State Gujarat
Key Dates
Publish Date 14 Oct 2026
Submission Date 02 Nov 2026
Open Date 05 Nov 2026
Finance
Tender Value 14.55 Lakhs
Tender Fee 500
EMD 29500
Exemption Available
Document List
BOQ_890214.xls
dcce7c37-8a61-4717-a8ab-43f97370254b.html
TENDER8381.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Oct 14, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Nov 02, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 3 days
Nov 05, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 6 days

Tender Documents

Download All (ZIP) ↓
xls

BOQ_890214.xls

html

dcce7c37-8a61-4717-a8ab-43f97370254b.html

pdf

TENDER8381.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender