Defence Statutory Bodies & Commissions/Committees Closing in 4 days TDR #58041259

Tender For Special Rep To Bldg No P-151 At Nhq Mts, Eme School,Vadodara.

Issued by Statutory Bodies & Commissions/Committees · Vadodara, Gujarat
Tender Value
7.93 Lakhs
Estimated cost
Bid Submission
02 Nov 2026
4 days left
EMD
15860
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Vadodara → Gujarat
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender For Special Rep To Bldg No P-151 At Nhq Mts, Eme School,Vadodara.

Corrigendum

Sr No Corrigendum Date Corrigendum Type New Submission Date
1 26-Oct-2026 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 02-Nov-2026

BOQ

Name of Work:- SPECIAL REP TO BLDG NO P-151 AT NHQ MTS, EME SCHOOL,VADODARA.
Sl. No. Item Description
1Demolition of stone slabs and tiles of any description or thickness in floors & wall, laid bedded & pointed in any mortar.
2M&L for 25 mm thick PCC 1:2:4 type B-0 using 12.5 mm graded stone aggregate in sub floors.
3M&L for Virified Ceramic tiles 9 to 10 mm thick dark shade (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match including screed bed or bedding layer of mortar 15 mm thick for laying floor finishes with CM 1:6
4M&L for Virified Ceramic tiles 9 to 10 mm thick dark shade (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, in vertical surfaces etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match including backing coat 10 mm thick in CM 1:3
5M & L for 18 to 20 mm thick machine cut green marbel stone in single piece as in steps and risers, landings, jambs, pillars, window cills, and like laid over cement screed and jointed with base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete including 10 mm thick plastering with cement mortar 1 : 3 including necessary adhesive complete all as specified
6M & L for machine cut kota stone slab in platform etc. of 20 - 25mm thick (the stone may be in one piece) including rubbing and polishing complete set over and including screed bed or bedding layer of mortar 20 mm thick for laying floor finishes with CM 1:6.
7Taking down chowkats or frame with shutter (without taking off shutter from the frame) n.exc 1.5sqm each
8Taking down chowkats or frame with shutter (without taking off shutter from the frame) Exc 1.5 Sq m but n.exc 4.00 Sq m each
9S&F of Powder coated aluminium frame for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc. complete all as specified
10S&F Powder coated aluminium (minimum thickness of powder coating 50 micron) for shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber/neoprene gasket required (Fittings shall be paid for separately) with extruded built up standard tubularsections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ paneling, C.P. brass/ stainless steel screws all complete as per architectural drawings and the directions of Engineer-in-charge.
11S&F 4.00mm+/-0.20mm thick tinted glass of bronze colour , selected ordinary quality and glazing with rubber beading or with glazing clips exc 0.5 sq. m in each pane as per instructions of manufacturers, all as specified and directed.
12M&L for 100mm butt hinges of stainless steel grade 202, 14 gauge thickness, medium weight of approved make fixed with pressed steel door frame/Angle iron frame/PVC door frame with screw complete all as specified and directed.
13S & F 200mm long Aluminium anodised barrel tower bolt of extruded section and fixed
14S & F 150 mm size extruded aluminium alloy handles, febricated type anodised
15S & F Factory made single extruded WPC (Wood Polymer Composite) solid door/ window/ Ceosetory windows & other Frames/ Chowkhat of size 45 x 85 mm comprising of virgin PVC polymer of K value 58-60(Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/ cum, screw withdrawal strength of 2200 N(Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modules of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/ moisture proof and fire retardant 152 SECTION 8 and fixed in position with MS hold fast/ lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-in-Charge. (M.S. hold fast/ lugs or SS dash fasteners shall be paid for separately).property of being ermite/borer proof, water/moisture proof and fire retardant and fixed in position with MS hold fast/SS dash fasteners of required dia and length all as specified and directed.
16S&F Factory made single extruded WPC (Wood Polymer Composite) solid plain flush door shutter of 30mm size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer-In-Charge. (Note: stainless steel butt hinges and necessary S S screws shall be paid separately)SS screws complete all as specified and directed.
17S & F 250 mm aluminium alloy anodised sliding door bolts, with hasp and staple (bolt type) not less than 12mm dia with and and fixing clips of sheet cast or extruded section and fixing bolt and sliding bolt of extruded section or cast aluminium and fixed to wooden door shutters
18S & F tubular curtain rails 25mm dia stainless steel 202 grade drapery type complete all as specified directed
19S & F in repairs stainless steel socket fancy type with bracket for 25mm dia stainless steel tubular curtain rod (design of socket shall be approved by GE/AGE at the time of execution) as directed
20S&F for Mild steel, plain, black sheet 1mm thick in wall cladding, steel gates and similar work, cut to size, holes punched; including round headed screws,clout nails or rivets and fixed to wood or steel framing with plain 40 mm lap joints with riveted or welded seams, including bending or turning up, mitred angles, etc. as required,complete all as specified and directed.
21S&F Roof trusses (framed) trusses purlins and fastening (etc.,angle, channel,tubular section,round pipe) or flat section including distance pieces, MS plates/ gusset plates, cleats, hold fast etc. conforming to Gde of steel Fe 410-0 or Fe 310-0 complete all as specified and directed.
22S &F for pre painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50 mm thick of any colour having tensile strength of 550MPa as in roof covering / cladding to wall, fixed with L or J hooks all as specified and directed.
23M & L for preparing new steel surface of any description not otherwise described over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer.
24Demolition of reinforced cement concrete as in Roofs, floors (other than ground floors), beams, staircases, landing, chajjas and similar suspended work
25Taking down cement plaster on brick/concrete surface including racking out joints hacking for key scrubbing down with water etc. complete all as specified and as directed
26Demolition brickwork or stone/boulder masonry built in cement mortar including all quoins, arches, pillars, etc, complete all as specified and as directed
27M&L Brickwork with sub class ‘B’ bricks straight or curved on plan exc 6 m mean radius built in CM 1:6 complete all as specified and as directed
28M & L Rendering 10 mm thick on fair faces of brick work or concrete surfaces of wall in cement mortar 1:6 for finished even and smooth (without using extra cement) complete all as specified and as directed
29M&L Rendering in two layer on fair faces of brick work or concrete sur-faces of wall 5 mm thick in CM 1:4 mixed with WPC as per manufacturers instructiion for finished even and smooth without using extra cement over 10 mm thick rendering in cement mortar 1:6 (WPC will be measured and paid separately).
30M&L Rendering 5 mm thick on fair faces of brick work or concrete sur-faces of ceiling in cement mortar 1:3 for finished even and smooth (without using extra cement) complete all as specified and as directed
31M & L for preparing new plastered surfaces of wall and applying two coats of oil bound distemper over and including a coat of 2mm average thickness birla/ equivalent wall care putty and one coat of primer all as specified and as directed.
32M& L for applying Two coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces.
33M & L for preparing new plastered surfaces of ceiling and applying three coats of white wash complete all as specified and as directed
34M & L for complete removal of loose / cracked concrete incl reinforcement if required, from RCC roof projection,chajja,fins,facia, roof bands etc and making good with PCC (1:11/2; :3) type A0 (using 12.5 mm graded stone aggregate) in any slab and in any position finished the surface even and smooth with out using extra cement including necessary form work and welding/binding of reinforcement (including reinforcement) if required complete and applying three coat of white wash/two coat of cement base pint to match with the existing surface as directed by the Engr- in -Charge . (Reiforcement will be measured and paid saperately under respective item complete all as specified and as directed
35M&L for Providing reinforced cement concrete (nominal mix) Type B1, 1:2::4 (using 20 mm Aggregate) as in Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like including necessary form work complete all as specified and directed. Note. (reinforcement shall be measured and paid separately)
36M & L for mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips all as specifed and as directed.
37Complete removal of existing water proofing treatment including plaster and concrete padding, roughening of concrete surface, cleaning and washing down the surface with water and removing debris/rubbish out side MD land complete all as specified and directed by Engr-In-Charge
38M&L for 40 mm avg thick PCC padding in cement concrete type B0 (1:2:4) using 12.5 mm graded stone aggr mixed with WPC as per manufacturer's instructions of cement finished surface even and fair without using extra cement for laying of WPT all as specified and directed. (WPC will be measured and paid separately).
39M&L 10mm thick rendering on roof in CM 1:3 mixed with WPC as per manufacturer's instructions of cement for finished even and smooth without using extra cement over PCC surface for laying APP membrane on roof (WPC will be measured and paid separately).
40M&L for water Proofing treatment to roof slabs by applying one coat of bituminious/polymerized primer confirming to IS-3384 @ 0.40 Ltrs/Sqm, 3 mm thick APP modified polymeric membrane of weight of 3 kg/sqm with non-woven polyester reinforcement shall be laid over a coat of bitumen S-35 grade (30/40) applied @1.20Kg /Sqm (minimum) with minimum 75 mm side overlaps and minimum 100 mm end overlaps, joints & overlaps shall be sealed and applying one coat of aluminium paint @ 0.11 Kg/Sqm over APP membrane complete all as specified and directed by Engr-In-Charge (Note: the primer and the membrane to be used shall be of the same manufacturer and to be applied by authorized applicator of OEM).
41Supply only Internal water proofing compound (Liquid type) all as specified and directed.
42M&L for chipping of spalled and loose concrete and cleaning rust from re-inforcement by sand brushing scrubbing down concrete surfaces with wire brushes cleaning with water allowed to dry applying a layer of zinc rich epoxy primer as anti-rust on all exposed reinforcement followed by a layer of bonding coat of a layer of epoxy adhesive on complete exposed surfaces of concrete and guniting for shortcrete 1 :2 (CM) mixed with epoxy resin and hardner (manufactured by FOSROC/BAUCHEMIC/CICO/PIDILITE)@ 2% by weight of cement in equal proportion using short crete pumps and allied equipment,in thickness 30 mm (average) all as per manufactureres instruction.(Upto 10 m height) complete all as specified and as directed
43S& F mild steel welded fabric of weight exe 2.5 Kg but n.exc. 4 Kg/ Sqm, fixed to steel members with spikes complete all as specified and as directedby Engineer-in Charge.(Upto 10 m height)
44Demolition of cement concrete of any description and in any position not otherwise specifically provided complete all as specified and as directed
45M & L for 75 mm thick PCC 1:3:6 mix type C2 using 40mm graded stone aggregate as in paving finishing cone surface (plinth protection) even and smooth without using extra cement complete all as specified and as directed
46M & L for ATT work treating the soil under plinth protection at the rate of 5 litres of emulsion per square metre of surface area complete all as specified and as directed
47M & L for ATT work treatment of soil under existing floors using emulsion @ one litre per hole, 300mm apart including drilling and plugging 12mm dia holes with cement mortar 1:2 (1 cement: 2 coarse sand) to match the existing floors complete all as specified and as directed
48Demolition of cement concrete (unreinforced) in ground floor and pavings n.exc.15 cm thickness (below or above ground level) and removing from site all as specified and directed.
49M & L for hard core gauge not exc. 63mm of broken bricks diposited spread and levelled in layers not exc. 15 cm watered and rammed to a true surface complete all as specified.
50M & L for 75 mm thick PCC 1:3:6 mix type C2 using 40mm graded stone aggregate as in paving ,floor complete all as specified and directed.
51M&L for factory made precast machine pressed kerb stones of PCC grade M-15 design mix and of shape and size rected, set jointed and pointed cement and sand mortar 1:4 fixed in repairs with and including necessary excavation and earthwork and making good the disturbed surfaces to match with the existing surfaces including removal of dispodal of rubbish complete all as specified and directed. Sizes shall be as under :- Length (L) not less than 300mm, Height (H) 300mm to 350mm, Thickness (T) 100mm and radius (R) 75mm including painting on kerb stone of synthetic enamel paint yellow or white colour complete all as specified and directed.
52M&L Sand Filling a layer of 50mm thick sand cushioning including filling the joints with sand as in floors/ paths including watering and consolidation complete all as specified and directed.
53Material and labour for 60 mm thick, machine made ,1st quality, precast cement concrete rubber moulded coloured interlocking paver blocks (coloured) , of triangular / Zigzag / Haxagone/ I , in shape or shap and design as approved, with grey cement and pigment , having M-35 Grade and conforming to IS 15658-2006 specifications , complete all as specified and directed.
54Taking down carefully copper/aluminum pt wiring (light fan, socket or power) complete including fittings such as switches, sockets, c/roses, lamp holders, tube light fittings, sketch fittings, wooden boards, bell push, call bell, MCBs, & regulators etc & making good to disturbed surfaces & matching with the existing colour of wall/floor etc.
55Taking down main switch, DB/change over/VTPN, MCCB AC box of any capacity.
56M&L for concealed point wiring with 1.5 Sqmm PVC-FRLS insulated, sheathed, copper conductor, stranded 1100 volt grade cable in & incl PVC conduit, including modular metal flush boxes & modular white cover plate with frame as per site requirement all fittings such as tees, bends, elbows, etc. of External diameter 20mm all as per site requirements PVC insulated & sheathed 1100 volt grade copper conductor, stranded 1.5 sqmm. cable as continuous earth lead complete incl cutting and chasing in stone/brick masonry all as specified and directed by Engr-in-charge .
57For one light, fan point controlled by one switch
58For one 5 Amp independent socket point controlled by one switch
59For one 3 pin ,5 Amp socket point with other switch on the same board
60All as per item No 56 here in before but for power point wiring using with 2.5 sqmm PVC-FR LS insulated ,sheathed, copper conductor stranded 1100 volt grade cable and 2.5 sqmm PVC insulated ,sheathed, copper conductor stranded 1100 volt grade cable as continuous earth lead complete all as specified and directed by engir in charge.
61S&F Modular switch, one way, 6 Amp 230, 1 module all as specified and directed by Engr in charge.
62S&F socket Modular 6 Amp-2/3 pin combined 2 module all as specified and directed by Engr in charge.
63S&F switch Modular, single pole, one way,16 Amp ,1 module 230 Volt all as specified and directed by Engr in charge.
64S&F socket modular 6/16 Amp, 2/3 pin combined ,2 module 230 Volt . all as specified and directed by Engr in charge.
65S&F ceiling rose, surface backlit,three terminal. all as specified and directed by Engr in charge.
66S&F modular fan step regulator 120W, 2 module. all as specified and directed by Engr in charge.
67S & F of ceiling fan BLDC complete with blades, down rod from existing roof / truss to fall ceiling, electronic regulator and accessories, 230V, 1200mm sweep. Min air delivery 210 CFM with service value 6.00 BEE, five star rated with brushless direct current motor including ceiling fan connecting up with three core flexible copper conductor cable of suitable size from ceiling roseall as specified and directed.Note : 1) Old ceiling fans shall be deposited to AGE E/M store yard for re issue to other buildings after repair/servicing or suryed off as per procedure in vogue etc.
68S & F of recess / surface mounting LED flat panel 2'X2' made of sheet steel housing duly powder coated with high efficient LEDs & glare free full opal diffiuser, IP20 of capacity 36 watt ,input voltage 140 -270 V AC , CCT 5700 K,lumin efficency 120lm/watt, surge protection upto 4KV , Voltage protection upto 440 V AC.PF >0.9 ,complete all as specified and directed. Note Warrenty on light should be of minimum 02 Years provided by the contractor.
69S&F testing and commissioning of MCB SP 6 Amp to 40 Amp 240 Volt 10 KA capacity having C-curve characteristics connected with suitable lugs.
70S&F testing and commissioning of MCB SPN 240 volt 40 Amp 10 KA capacity having C-curve characteristics connected with suitable lugs .
71S&F sheet metal enclosure for DB double door, IP-43 when MCBs to be used SPN, 8 way, 240 V with 200 Amps rated bus bar .
72S & F of Inverter LED street light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection,inbuilt battery Back-up auto ON/OFF/Dimmer(Pre-programable), including bracket made out of GI pipe light grade 32mm bore not less than 1.20m long bent to shape required fixed to pole with suitable size 2 Nos clamps made out of 25X3mm flat iron with nut, bolts and washers complete complete all as specified and directedNote Warrenty on light should be of minimum 02 Years provided by the contractor.
73Earthing Complete with galvanised steel earth plate electrode 60cmx60cmx6mm thick burried directly in ground vertically to a depth not less than 2.5 metre below ground level with top edge of the earth plate at a depth not less than 1.5 mtr below ground level earth plate surrounded from all sides by 15cm thick packed layer of charcoal dust and common salt filling in alternate layers and electrode connection by using galvanized earth lead wire 4 mm dia by means of bolts, nuts, check nuts and washers made of galvanised iron and thimbles and other end of the earth wire connected to main switch board protected by galvanised iron medium grade pipe 40mm bore in wall/floor/and GI Pipe 20 mm bore light grade for watering with funnel and wire mesh PCC chamber in cement concrete 1:3:6 type C-2 and RCC pit cover including necessary excavation and earth work in any type of soil, returning slurry approved soil and disposed of surplus soil to a distance not exceeding 50 Mtr away all as shown in electrical plate No 3 of SSR 2009 ( Part-I).Notes (a) The unit rate shall include for GI protection pipe, GI watering pipe, wire mesh, funnel and excavation, RCC pit cover, test point, galvanised iron strip from top of earth plate upto 7.5 metres above ground level and if GI protection pipe is less than 7.5 metres, no price adjustment shall be made.(b) PCC pit shall be provided at least 50cm away from the earth pit and not just on the earth pit and extra cost of additional length of water pipes and fittings, junction, elbow etc shall be deemed to be included in the unit rate.(c) If the testing result of earthing is not found below 5 Ω then the contractor shall do another earthing work at his own cost and nothing shall be permissible on this account.(d) Earthing work will be carried out in presence of MES representative. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 58041259
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 7.93 Lakhs
LAST DATE 02-11-2026
Authority
Authority Name Military Engineer Services
Work Description Tender For Special Rep To Bldg No P-151 At Nhq Mts, Eme School,Vadodara.
Basic Detail
Tender No 8131
Bidding Type Tender
Location
City Vadodara
State Gujarat
Key Dates
Publish Date 26 Oct 2026
Submission Date 02 Nov 2026
Open Date 03 Nov 2026
Finance
Tender Value 7.93 Lakhs
Tender Fee 500
EMD 15860
Exemption Available
Document List
1515189a-87e5-46a9-8d52-79085d80b081.html
BOQ_890276.xls
Tendernotice_1.pdf
Tenderpages8131.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Oct 26, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Nov 02, 2026
18:00 IST

Corrigendum-1 Issued

Clarifications on tender conditions and amendments issued.

Upcoming · 4 days
Nov 02, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 4 days
Nov 03, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 5 days

Tender Documents

Download All (ZIP) ↓
html

1515189a-87e5-46a9-8d52-79085d80b081.html

xls

BOQ_890276.xls

pdf

Tendernotice_1.pdf

pdf

Tenderpages8131.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender