Housing Urban and Rular Development Government Departments Closing in 16 days TDR #58041013

Tender For Electrical Repair & Renovation For 2 No. maintenance of Quarter, 2 Nos. Nurshing Staff Quarter And 4 Nos. Group D Quarter At Silbarihat Phc In The District Of Alipurduar-----Electrical Installation Work.

Issued by Government Departments · alipurduar, West Bengal
Tender Value
15.22 Lakhs
Estimated cost
Bid Submission
17 Nov 2026
16 days left
EMD
30455
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
alipurduar → West Bengal
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Electrical Repair & Renovation For 2 No. maintenance of Quarter, 2 Nos. Nurshing Staff Quarter And 4 Nos. Group D Quarter At Silbarihat Phc In The District Of Alipurduar-----Electrical Installation Work.

Corrigendum

Sr No Corrigendum Date Corrigendum Type New Submission Date
1 28-Oct-2026 DateCorri1 Date 17-Nov-2026

BOQ

Name of Work:- Electrical Repair & renovation for 2 no. MO Quarter, 2 nos. Nurshing staff Quarter and 4 nos. Group D Quarter at Silbarihat PHC in the district of Alipurduar-----Electrical Installation work.
Sl. No. Item Description
1SUB-HEAD - Distribution Wiring
2Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable etc. as required.
3Group B
4Supplying and drawing following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required.
53 x 1.5 sq. mm
63 x 2.5 sq. mm
73 x 4 sq. mm
83 x 6 sq. mm
9Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.
1020 mm
1125 mm
12SUB-HEAD - PLUGS & SOCKETS
13Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.
145/6 A switch
1515/16 A switch
163 pin 5/6 A socket outlet
176 pin 15/16 A socket outlet
18Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc. as required.
194 Module (125mmX75mm)
206 Module (200mmX75mm)
21Supplying and fixing 2-Module GI box with modular plate and cover in front on surface or in recess, including providing and fixing 15/16 A modular socket outlet ,connections etc. as required.
22SUB-HEAD - BDB,PDB,VTPN ETC
23Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
2416 way , Double door
25Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
26Single pole
27Supplying and fixing following rating, double pole, 240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.
28Supplying and fixing DP sheet steel enclosure on surface/ recess along with 25/32 A 240 V \\"C\\" curve DP MCB complete with connections, testing and commissioning etc. as required.
29SUB-HEAD - Laying of Cable
30Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required.
31Upto 35 sq. mm (clamped with 1mm thick saddle)
32Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.
332 X 6 sq. mm (19mm)
34SUB-HEAD - SUPPLY & FIXING OF FANS
35Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
36Providing and fixing M.S. fan clamp type I or II of 16 mm dia M.S. bar, bent to shape with hooked ends in R.C.C. slabs or beams during laying, including painting the exposed portion of loop, all as per standard design complete.
37Installation, Testing and Commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS/HFFR PVC insulated, copper conductor, single core cable etc. as required.
38Installation, Testing and Commissioning of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required.
39Upto 450 mm sweep
40Extra for fixing the louvers/ shutters complete with frame for a exhaust fan of all sizes.
41SUB-HEAD - Supply & Fixing of Light Fittings
42Installation, Testing and Commissioning of pre-wired, fluorescent fitting / compact fluorescent/ LED fitting of all types, complete with all accessories and tube/lamp etc. directly on ceiling/ wall, including connections with 1.5 sq. mm FRLS/HFFR PVC insulated, copper conductor, single core cable and earthing etc. as required.
43Supplying and fixing of 32 mm dia X 2.00 metres long G.I. pipe (medium class) bracket for mounting of fluorescent / HPMV / HPSV street light fitting on pole including bending the pipe to the required shape, 2 nos 40 mm X 3 mm flat iron clamps with nuts, bolts and washer, painting the flat iron with primer and finish paint etc. as required.
44SUB-HEAD - Compound Light
45Supplying, Installation, Testing & Commissioning of Street light LED fixture, powder coated pressure die cast aluminium body with built in or separate driver as per the requirement with Driver efficiency >85%, Input voltage: 140-270 Volt AC, frequency 50/60 hz, Operating temp range -5 0C to 50 0C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2, P. F.≥0.95, IP-66,IK-10, CRI >70, under voltage and over voltage protection, EMI-EMC as per CISPR-15, lenses for beam angle as per IESNA type I/II/III as per the width of the road and the project requirement., suitable to fit in up to 65mm dia pipe, life time (LED,Driver & electrical circuitary) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM
46(Standard Deviation Color Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy >135 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted.. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). LED Street light fixture, powder coated pressure die cast aluminium body (System lumen efficacy >135 lm/Watt).
4745 watt
48SUB-HEAD - Call Bell
49Supplying and fixing call bell/ buzzer suitable for single phase, 230 V, complete as required.
50SUB-HEAD - Earthing Installation
51Earthing with G.I. earth pipe 4.5 Meter long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. (but without charcoal/ coke and salt) as required.
52Supplying and laying 6 SWG G.I. wire at 0.50 Meter below ground level for conductor earth electrode, including connection/ termination with GI thimble etc. as required.
53Providing and fixing earth bus of 50 mm X 5 mm copper strip on surface for connections etc. as required.
54PART-B - PWD SOR and Non-Schedule Items
55SUB-HEAD - MISCELLANEOUS
56Dismantling the existing fitting, fixture, DBs, etc from old position and reinstalled the same useable accessories as per the site situation with own tools and tackles.
57Supply & Fixing 240 V, 25 A, Modular type starter (Brand approved by EIC) with 25A Modular switch type DP MCB (CCurve) and 4 Module GI Modular type switch board with 4 Module top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc.
58Supplying & Fixing GI waterproof type looping cable box size 200x150x100 mm deep having 4 mm thick comprising of one 250 V 15 A kit-kat fuse unit, one NL on porcelain insulator, one compression type brass cable gland for upto 2- core 16 sqmm PVC/A cable and having lined with rubber gasketted GI top cover with brass machine screws etc., earthing terminal with lug, on steel tubular pole near base, including S&F 40x6 mm thick, MS clamps with bolts, nuts etc. including painting with anticorrosive paint
59SUB-HEAD - Supply of Cable
60Supplying and delivery of following size Armoured cables XLPE/PVC insulated are designed for 1.1 kV Stranded Aluminium conductor, high tensile galvanized steel wire/strip armour for mechanical protection, and PVC/FR PVC outer sheathing power cable of following size.(IS 7098 Part - 1/2011 with Up To Date Amendments.)
612 core 6 Sq. mm
62SUB-HEAD - FANS
63Supply & delivery of 230 V, 50 Hz, single phase, 58 watts, 56\\" (1400 mm) Sweep, speed 300 rpm (minimum), A.C. Ceiling Fan and class ofinsulation: B, 3 nos. metal (Aluminium alloy) blades, 30 cm long down rod (14 SWG & higher thickness), 2 nos. canopies, safety rope, copperwinding, steel/Al body. Power Factor not less than 0.9 and minimum airdelivery 250 cu.m/min (minimum), without Regulator including capacitorwith safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for compliant to IS 374:2019 and external connections with 1.5 sq.mm FR, PVC insulated copper conductor single core cable and earthing etc. as required.
64Supply & delivery of 230 V, 50 Hz, single phase, 40 watts , 9\\" (230 mm) Sweep, speed 1350 rpm (minimum), A.C. Exhaust Fan and class of insulation: B, 3 nos. metal (Aluminium alloy) blades, copper winding, steel/Al body. Power Factor not less than 0.9 and minimum air delivery 650 cmh (minimum) including capacitor with safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for compliant to IS 374:2019 and external connections with 1.5 sq.mm FR, PVC insulated copper conductor single core cable and earthing etc. as required.[Make: EPC/Crompton/Usha/Havells/Orient]
65SUB-HEAD - Supply of Light Fittings
66Supply & Fixing of 240V, 9 watt LED lamps of following wattage with glare free light distribution having minimum luminous efficiency of 100 Lm/ Watt or better & 50,000 LED burning hours or more. [Make- Philips/ Crompton/ Wipro or manufacturer with own NABL accredited lab with valid test certificate] [LED lamps & accessories shall have BEE certification]
67Supply & Delivery of minimum10-12 Watt LED Bulkhead light fittings complete with all accessories having die cast aluminium housing finished in premium white powder coating with CCT (5700K-6500K) having minimum luminous efficiency of 100 Lm/ Watt or better & 50,000 LED burning hours or more. [Make- Philips/ Crompton/ Wipro or manufacturer with own NABL accredited lab with valid test certificate] [LED lamps & accessories shall have BEE certification]
68Supplying and delivery of LED Industrial Batten light made of CRCA Sheet Body (Thickness ≥ 0.50 mm) and construction as per relevant IS, along with LED lamp (Opal finish polycarbonate housing with Aluminium end-cap) voltage AC 140-270 Volt, freq 50/60 hz, Operating temp range 0o to 40o C, internal surge protection of 2.5 KV(internal) with Short & Open circuit protection , THD < 10% , P. F.≥0.9, IP20, CRI >80, and minimum 40000 Burning Hours (Life projection shall be calculated as per TM-21 methodology), CCT 5700°K /6500°K, and Fixture shall be of relevant BIS standard and trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing, with Minimum 5 year OEM warranty. All test report except L80 should be from 3rd party NABL accredited Lab as per BIS shall be submitted.(System lumen efficacy ≥115 lm/Watt)
69Single fittings along with S/F of 1 no. 18-20 W LED lamp as per specification
70Note: 1) All the above rates should be quoted inclusive of all taxes, duties and all ancilery charges with cost of maintenance, servicing, supply & replacement of spares for 1 (One) year from the date of commissioning. 2) Total is rounded off to the nearest rupees. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 58041013
AUTHORITY Government Departments
TENDER VALUE 15.22 Lakhs
LAST DATE 17-11-2026
Authority
Authority Name Public Works Department
Work Description Tender for Electrical Repair & Renovation For 2 No. maintenance of Quarter, 2 Nos. Nurshing Staff Quarter And 4 Nos. Group D Quarter At Silbarihat Phc In The District Of Alipurduar-----Electrical Installation Work.
Basic Detail
Tender No WBPWD/EE/CED/eNIT-55/2026-2027
Bidding Type Tender
Location
City alipurduar
State West Bengal
Key Dates
Publish Date 28 Oct 2026
Submission Date 17 Nov 2026
Open Date 19 Nov 2026
Finance
Tender Value 15.22 Lakhs
Tender Fee Ref. Documents
EMD 30455
Exemption Not Available
Document List
02407cae-4992-46ce-8e36-172a997ac610.html
BOQ_5186936.xls
Tendernotice_1.pdf
Tendernotice_2.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Oct 28, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Nov 17, 2026
18:00 IST

Corrigendum-1 Issued

Clarifications on tender conditions and amendments issued.

Upcoming · 16 days
Nov 17, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 16 days
Nov 19, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 18 days

Tender Documents

Download All (ZIP) ↓
html

02407cae-4992-46ce-8e36-172a997ac610.html

xls

BOQ_5186936.xls

pdf

Tendernotice_1.pdf

pdf

Tendernotice_2.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender