Tender For Repairing & Rennovation Works Of Quarters At Primary Tier (Phc-Bedded & Bphcs/Rhs) Health Facility Under Various Districts Of West Bengal.----Internal & External electrical installation Works Of Diff. Quarters At Narajole Phc, Ghatal, Pasc
Tender Overview
Project Description
Tender for Repairing & Rennovation Works Of Quarters At Primary Tier (Phc-Bedded & Bphcs/Rhs) Health Facility Under Various Districts Of West Bengal.----Internal & External electrical installation Works Of Diff. Quarters At Narajole Phc, Ghatal, Paschim Medinipur.
BOQ
| Sl. No. | Item Description |
| 1 | Internal E.I Work for (2 Nos. MO Quarter,2 Nos. Nurses Quarter,6 nos. Gr. D QuarterDismantling old TPN/ SPN DBs, different sizes cable, wires, SB, JB, Power boards etc including ceiling fans, & tube light fittings & Window type RAC incl. frame and stacking the usable materials in store as per direction of EIC. |
| 2 | Supply &Fixing Sheet Steel Main Switch on flat iron frame on wall for 240V,30/32A with fuse on Line & Neutral. |
| 3 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) [For Quarters] |
| 4 | 12 way, Double door |
| 5 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 6 | Single pole |
| 7 | Supplying and fixing following rating, double pole, 240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 8 | Supplying and fixing metal box of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc. as required. |
| 9 | 180 mm X 100 mm X 60 mm deep |
| 10 | 200 mm X 150 mm X 60 mm deep |
| 11 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. |
| 12 | a) 20 mm dia pipe |
| 13 | b) 25 mm dia pipe |
| 14 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable in surface/ recessed steel conduit, with piano type switch, phenolic laminated sheet, suitable size MS box and earthing the point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable etc. as required. |
| 15 | Group B |
| 16 | On board |
| 17 | Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in surface/recessed medium class PVC conduit as required. |
| 18 | 2 X 6 sq. mm + 1X 6 sq. mm earth wire(from Mitter to Main switch to SPNDB) |
| 19 | 2 X 4 sq. mm + 1 X 4 sq. mm earth wire(ac machine) |
| 20 | 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire [for 16 A Power plug & CB & 1x6A+1x16A ] |
| 21 | 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire [ For glow sign board and 6 A separate plug) |
| 22 | Finishing of the PVC insulated wire ends by socketting with pin/ ring type copper sockets and insulated tapes etc., including supplying sockets, tapes. |
| 23 | 6 sqmm |
| 24 | 4 sqmm |
| 25 | 2.5 sqmm |
| 26 | Supply & Fixing 240 V, 3 nos. 6A, & 1 no. 20A plug socket with separate 3 nos. 6 A & 1 no. 20A Piano key type switch, indicator & 20A switch type SP MCB (Brand approved by EIC) on sheet metal switch board embedded in wall incl. S & F 240x200x65mm MS (16SWG) switch board and bakelite/perspex top cover of 3mm thick by Brass screws after making housing for switch by cutting bakelite/perspex cover and making necessary connections as required. |
| 27 | Supplying and fixing metal box of 150mm X 75mm X 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc. as required. |
| 28 | Supplying and fixing of 15/16 Amp piano type switch/ socket on the existing switch box/ cover including connections etc. as required. |
| 29 | 15/16 A switch |
| 30 | 6 pin 15/16 A socket outlet |
| 31 | Supplying and fixing metal box of 150mm X 75mm X 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover infront including providing and fixing 3 pin 5/6 A socket outlet and 5/6 A piano type switch, connections, painting etc. as required. |
| 32 | Supply & Fixing 240 V, 25 A, Modular type starter (Brand approved by EIC) with 25A Modular switch type DP MCB (CCurve) and 4 Module GI Modular type switch board with 4 Module top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc. |
| 33 | Supply & Fixing 240 V, 25 A, 3 pin Modular type plug socket (Brand approved by EIC), with modular type plug top with indicator and switch with 2 Module GI Modular type switch board with top cover plate flushed in wall and making necy. connections with PVC Cu wire and earth continuity wire etc. |
| 34 | Installation, Testing and Commissioning of pre-wired, fluorescent fitting / compact fluorescent/ LED fitting of all types, complete with all accessories and tube/lamp etc., including supplying and fixing ball and socket arrangement, 2 Nos. down rods of 20 mm dia X 1.6 mm thick steel conduit upto 30 cm length, painting and wiring the down rods and connections with 1.5 sq. mm FRLS/HFFR PVC insulated, copper conductor, single core cable and earthing etc. as required. |
| 35 | LED Batten light (System lumen efficacy ≥105 <120 lm/Watt).Supplying, Installation, Testing & Commissioning of LED surface mounted Batten light of following body material and construction as per IS : 10322 with driver (Replaceable) as per the requirement with Driver efficiency >85%, Operating voltage AC 140- 270 Volt, frequency 50/60 hz, Operating temp range -5 °C to 40 °C, internal surge protection of 2.5 KV with Short & Open circuit protection, THD < 10%, P. F.≥0.95, IP20, CRI >80, Flicker free, (flicker should be below 5 %), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Colour Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard. Manufactures Word Mark/ Name Engraved/Embossing/ Screen printing on housing. completein all respect i/c external connections with 1.5 sqmm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in- Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C).Powder Coated CRCA Sheet Body (Thickness > 0.50 mm) |
| 36 | 18- 22 Watt) |
| 37 | Supplying and fixing extra conduit down rod of 20 mm dia, 2 X 10 cm length, wiring with 2 X 1.5 sq. mm FRLS/HFFR PVC insulated, copper conductor, single core cable including painting etc. as required. (Note : More than 5 cm length shall be rounded to the nearest 10 cm and 5 cm or less shall be ignored) |
| 38 | Supply& Delivery of 240V 9 W LED lamp with CCT (5000K-6500 K) , with minimum luminious efficacy ≥105 & <120 lumen/watt or better. The LED Lamp and accessories shall have BEE Certification. |
| 39 | Supply & Delivery of 10 watt LED Bulk Head or higher with minimum luminious efficacy 100 lumen/wt. (Make : Philips - Signify/ Panasonic / Crompton/ wipro/ Jaquar/Bajaj/ Havells) |
| 40 | Providing and fixing M.S. Fan clamps of 16 mm dia M.S. bar, bent to shape with Hooked ends in R.C.C. slabs or beams during laying, including painting the exposed portion of loop, all as per standard design complete |
| 41 | Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. |
| 42 | Brush Less Direct Current (BLDC) Fan without Remote Supply, Installation, Testing and Commissioning of ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. metal (Aluminium alloy) blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, steel/Al body Power Factor not less than 0.9, Service Value (CM/M/W) minimum as below, 350 RPM (tolerance as per IS : 374-2019), THD (Total Harmonic Distortion) less than 10%, suitable for operation with regulator for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 0C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC supply, Ceiling Fan compliant to IS 374:2019 fan i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as require |
| 43 | 1200mm, service value ≥ 6.0 CM/Min/Watt, air delivery 210 CM/Min (Minimum) |
| 44 | Installation, Testing and Commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS/HFFR PVC insulated, copper conductor, single core cable etc. as required. |
| 45 | Numbering of ceiling fan/ exhaust fan/ fluorescent fittings as required |
| 46 | Installation, Testing and Commissioning of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required. |
| 47 | Extra for fixing the louvers/ shutters complete with frame for a exhaust fan of all sizes |
| 48 | S& Delivery 250V. 50 Hz. Following 920 r.p.m. 9\\" (230mm) Heavy Duty AC Exhaust Fan (EPC make) |
| 49 | Earthing with G.I. earth pipe 4.5 Meter long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. without charcoal/coke and salt as required. |
| 50 | Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required. |
| 51 | Connecting the equipments to earth busbar including S & F GI (Hot Dip) wire of size as below on wall/floor with staples buried inside wall/floor as required and making connection to equipments with bolts, nuts, washers, cable lugs etc. asrequired and mending good damages No. 4 SWG |
| 52 | Excavation of morrum soil for installation of Earth Electrode and filling & ramming. |
| 53 | Supplying and fixing call bell/ buzzer suitable for single phase, 230V, complete as required. |
| 54 | Compound LightSupply & delivery of hot dip galvanised (As per IS: 2629/IS 2633/IS 4759 & with its latest amendment) 6 mtrs length Decorative octagonal pole made of HT steel(Sheet thickness-3 mm) conforming to grade S355JO/JR of BSEN 10025 along with welded base plate of required size stud of termination of 4 core 10/16/25/35 sqmm al (Ar) cable incl S&F 1 no 6 amp SP MCB (c-series) with 4 way stud for each out going circuit to the fittings with proper pad locking arrangement for the pole. [Top dia (A/F)-70 mm Bottom dia (A/F)- 130 mm] Base plate size: 200 mm (L)x 200 mm(W) x 12 mm(Thickness). Foundation Bolt-4-M20 x 600 mm(L) x 4 nos 'J' type bolts (Make-Bajaj / Utkarsh / Calcutta Poles) (T.C & G.C must be submitted to EIC before execution) |
| 55 | Supply of 1 Mtr. Galvanized Decorative Swan neck Type single Arm Bracket made of MS pipe as per IS:1161 (Make-Bajaj / Valmont / Utkarsh) N.B: OEM declaration or authorization from minimum 2 nos of manufacturers from above make list need to be provided at the time of tender submission from the power of attorney holder or authorized signatory not below the rank of Zonal Head of that OEM |
| 56 | Errection of the following octagonal pole by designing & casting RCC(M-16)foundation of suitable size as specified below considaring the safe soil bearing capacity at site as 10 T/sq m incl excavation of earth providing cutting bending and placing in position reinforcement as per drawing & providing pipe for cable entry & exit as per required & providing and fixing of 4 nos foundation bolt (J type) as specification below & as per drawing on ground surface incl back filling cleaning extra earth with sand cement plastering and painting---up to 6 mtr. [Foundation size-500mm(L)x500mm(W)x1200mm(H), J Bolt size-M20 x 600 (for 6 mtr. pole for compound light) |
| 57 | Supplying & Fixing 40 mm dia 3.20 metre long (incl. bends) ‘L‘ Type service bracket on wall for carrying 2 wires and an earth wire complete with Galv. clamp for stay, insulators etc., 7/14 SWG stranded Galv. (Hot Dip) wire for stay with 230x13 mm dia straining serews, 75x88 mm porcelain shackle insulators with Galv. (Hot Dip) strips etc. and painting |
| 58 | Supplying and Fixing GI water proof looping cable box having hinged GI Top Cover having 4 mm thick with rubber gasket lining, railway type mechanical locking arrangement, earthing terminal with lug etc. of the following sizes as indicated below, Comprising of one 250 V, 15 A Kit-Kat fuse unit, one NL on porcelain insulator etc. and housing the same in pole surface by required size MS flat pati and . incl. painting. |
| 59 | LED Street light fixture, powder coated pressure die cast aluminium body (System lumen efficacy ≥120 <135 lm/Watt) Supplying, installation, Testing & Commissioning of Street light LED fixture powder coated pressure die cast aluminium body with driver as per the requirement with Driver efficiency >85%, Input voltage: 140-270 Volt AC, frequency 50/60 hz, Operating temp range -5 0C to 50 0C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2, P. F.≥0.95, IP-66,IK-10, CRI >70, under voltage and over voltage protection, EMIEMC As per CISPR 15 , lenses for beam angle as per IESNA type I/II/III as per the width of the road and the project requirement., suitable to fit in up to 65mm dia pipe, life time (LED, Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Colour Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 <135 lm/Watt output. LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). |
| 60 | 90 Watt |
| 61 | 50 watt |
| 62 | Supply and fixing of double door 2+12 way S.P.N. DB (Approved make) timer control board with box having the following accessories incl interconnection. as directed by EIC.(i) 415V, 32A FPMCB on DIN-rail - 1 no.(ii) 240V, 6-32A SPMCB of breaking capaciy 10KA, 'C' curve - 3 nos.(iii)4 pole power contractor 250V 25A coil . (Havells make) - 1No(iv) Mannual time switch - 1 no.(v) Toggle switch for auto/manual operation - 1 no.(vi)Necessary connection by copper wie as required.[Make: ABB/Siemens/Legrand/L&T/Havells] |
| 63 | Inter connection of LED fittings by 3 x 1.5 Sq.mm. PVC insulated copper wire from loop box with 19 mm bore PVC polythene pipes as per direction of EIC. |
| 64 | Supply & Delivery of following sizes 1.1 KV Gr. XLPE insulated as per IS -7098 (Part -1) 1988 armoured sheathed Aluminium conductor cable. (Make :- Havells / Polycab / RR Kabel). |
| 65 | 4 core 16 Sqmm |
| 66 | Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required. |
| 67 | Upto 35 sq. mm (clamped with 1mm thick saddle) |
| 68 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling thetrench etc as required. |
| 69 | Upto 35 sq. mm |
| 70 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.. |
| 71 | 4 X 16 sq. mm (28mm) |
| 72 | Earthing with G.I. earth pipe 4.5 Meter long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. without charcoal/coke and salt as required. |
| 73 | Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required. |
| 74 | Supplying & fixing medium gauge GI Pipe (ISI-Medium) Protection with necessary fittings and jointing metarials as required. 32 mm dia. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 21 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 23 daysTender Documents