Housing Urban and Rular Development Government Departments Closing in 8 days TDR #58040300

Tender For Repairing & Replacement Of Damaged Tube Light , Compound Light And Allied electrical installation Work At Kharagpur Sub-Divisonal Court C Us In The Dist Of Paschim Medinipur.

Issued by Government Departments · Medinipur West, West Bengal
Tender Value
2.52 Lakhs
Estimated cost
Bid Submission
31 Oct 2026
8 days left
EMD
5045
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Medinipur West → West Bengal
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Repairing & Replacement Of Damaged Tube Light , Compound Light And Allied electrical installation Work At Kharagpur Sub-Divisonal Court C Us In The Dist Of Paschim Medinipur.

BOQ

Name of Work:- Repairing & Replacement of damaged tube light , compound light and allied E.I Work at Kharagpur Sub-Divisonal Court C us in the Dist of Paschim Medinipur.
Sl. No. Item Description
1LED Batten light (System lumen efficacy ≥105 <120 lm/Watt).Supplying, Installation, Testing & Commissioning of LED surface mounted Batten light of following body material and construction as per IS : 10322 with driver (Replaceable) as per the requirement with Driver efficiency >85%, Operating voltage AC 140- 270 Volt, frequency 50/60 hz, Operating temp range -5 °C to 40 °C, internal surge protection of 2.5 KV with Short & Open circuit protection, THD < 10%, P. F.≥0.95, IP20, CRI >80, Flicker free, (flicker should be below 5 %), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Colour Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard. Manufactures Word Mark/ Name Engraved/Embossing/ Screen printing on housing. completein all respect i/c external connections with 1.5 sqmm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in- Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C).Powder Coated die cast body(Thickness > 1.20 mm) [DSR(E&M)2025/P46/8.9]
218- 22 Watt
3LED Street light fixture, powder coated pressure die cast aluminium body (System lumen efficacy ≥120 <135 lm/Watt)Supplying, installation, Testing & Commissioning of Street light LED fixture powder coated pressure die cast aluminium body with driver as per the requirement with Driver efficiency >85%, Input voltage: 140-270 Volt AC, frequency 50/60 hz, Operating temp range -5 0C to 50 0C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2, P. F.≥0.95, IP-66,IK-10, CRI >70, under voltage and over voltage protection, EMIEMC As per CISPR 15 , lenses for beam angle as per IESNA type I/II/III as per the width of the road and the project requirement., suitable to fit in up to 65mm dia pipe, life time (LED, Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Colour Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 <135 lm/Watt output. LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). [DSR(E&M)2025/P51/8.13]
472 watt
5Supply & Delivery of 240V 9 W LED lamp (minimum Luminous Efficacy 100lm/w.) (Make : Panasonic / Crompton/ wipro/ Bajaj/ Havells)
6S & F of 2.5mfd fan condenser in place of damaged (Tipcon make)
7Supply & Fixing 40W LED Decorative Post Top light fitting in Pressure die cast Aluminum base with Prismatic polycarbonate diffuser, LED lamp colour Temp-4000K Spun Aluminium top cover & IP66 Protection complete with all accessories incl. supply & fixing of 2 nos. 40mm dia ISI-M GI pipe having 1.5 Mtr. lenth in existing pillar incl painting as perG.S & as per direction of E.I.C. [K-LITE 4998 GADAI / PHILIPS : BGP300 LED 50757 PSU PCINS1 / WIPRO : LP07-671-XXX-40-CL]NOTE : All street light / compound light/ Post Top Lantern should contain internal surge protection with external 10KV surge protection (linline SPD).
8Supply and delivery of following size 1.1 kV Gr., 415V XLPE insulated armoured Al cable. (Make- Polycab / Havells / Gloster)
92 core 10 Sq. mm (for Compound Light)
10Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. [DSR(E&M)2025/P7/10.1]
11upto 35 Sq.mm
12Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. [DSR(E&M)2025/P68/1.23]
132 X 10 sq. mm (19mm)
14Supplying and fixing following piano type switch/ socket on the existing switch box/ cover including connections etc. as required. [DSR(E&M)2025/P68/11.1]
155/6 amps switch
163 pin 5/6 A socket outlet
1715/16 A switch
186 pin 15/16 A socket outlet
19Supplying and fixing call bell/ buzzer suitable for single phase, 230 V, complete as required
20Supply & Fixing of 415 Volt, 25 Amp 2 pole with NO+NC Contractor on exsisting Timer DB replaced by damaged one (Make - L&T, Model-MNX 9-2P Cat No. - CS90232 03/ABB/Schneider)
21S & F 250 V,50 HZ 18\\" (450mm) high flow oscilating type metal body wall Braket Fan operated by pull cord switch with inbuilt regulator (Make-orient,model-Tornado wall-II) Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 58040300
AUTHORITY Government Departments
TENDER VALUE 2.52 Lakhs
LAST DATE 31-10-2026
Authority
Authority Name Public Works Department
Work Description Tender for Repairing & Replacement Of Damaged Tube Light , Compound Light And Allied electrical installation Work At Kharagpur Sub-Divisonal Court C Us In The Dist Of Paschim Medinipur.
Basic Detail
Tender No WBPWD/AE/KESD/NIT-03/e-T /2026-2027
Bidding Type Tender
Location
City Medinipur West
State West Bengal
Key Dates
Publish Date 14 Oct 2026
Submission Date 31 Oct 2026
Open Date 02 Nov 2026
Finance
Tender Value 2.52 Lakhs
Tender Fee Ref. Documents
EMD 5045
Exemption Not Available
Document List
2911.pdf
5bb7cad7-a451-4c12-8dd3-305bc0210ae0.html
BOQ_5187217.xls
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Oct 14, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Oct 31, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 8 days
Nov 02, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 10 days

Tender Documents

Download All (ZIP) ↓
pdf

2911.pdf

html

5bb7cad7-a451-4c12-8dd3-305bc0210ae0.html

xls

BOQ_5187217.xls

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender