Housing Urban and Rular Development Local Bodies Closing in 6 days TDR #58037106

Tender For Construction Of 15 Nos. Security Check Post At Naya Gaon, Jayanti Majra, Mullanpur Barrier, Sarangpur Barrier, Togan Barrier, Makhanmajra, Raipur Kalan, Dhillon Barrier, Kishangarh, Zirakpur Barrier, Faidan Barrier, Mohali Barrier, Badheri

Issued by Local Bodies · Chandigarh, Chandigarh
Tender Value
5.19 Crore
Estimated cost
Bid Submission
21 Oct 2026
6 days left
EMD
10.38 Lakhs
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Chandigarh → Chandigarh
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Construction Of 15 Nos. Security Check Post At Naya Gaon, Jayanti Majra, Mullanpur Barrier, Sarangpur Barrier, Togan Barrier, Makhanmajra, Raipur Kalan, Dhillon Barrier, Kishangarh, Zirakpur Barrier, Faidan Barrier, Mohali Barrier, Badheri Barrier Naka At Dividing Road 55/56, Jh Ur Barrier, Chandigarh.

BOQ

Name of Work:- Construction of 15 Nos. Security Check Post at Naya Gaon, Jayanti Majra, Mullanpur Barrier, Sarangpur Barrier, Togan Barrier, Makhanmajra, Raipur Kalan, Dhillon Barrier, Kishangarh, Zirakpur Barrier, Faidan Barrier, Mohali Barrier, Badheri Barrier Naka at dividing Road 55/56, Jh ur Barrier, Chandigarh.
Sl. No. Item Description
1Civil Item
2Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, for all lift, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.
3All kinds of soil.
4Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 and for all lift.
5Supplying and filling in plinth with sand under floors, including watering,ramming, consolidating and dressing complete.
6Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:5:10 (1 cement : 5 coarse sand (zone-III) derived from natural sources : 10 graded stone aggregate 40 mm nominal size derived from natural sources)
7Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :4.1.2 1:1½:3 (1 Cement: 1½ coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mmnominal size derived from natural sources)
8Providing and laying cement concrete in retaining walls, return walls, walls (any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor etc., up to floor five level, excluding the cost of centering, shuttering and finishing:4.2.2 1:1½:3 (1 cement : 1½ coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources).
9Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth.
10Centering and shuttering including strutting, propping etc. and removal of form for : Foundations, footings, bases of columns, etc. for mass concrete
11Centering and shuttering including strutting, propping etc. and removal of form for : Suspended floors, roofs, landings, balconies and access platform
12Centering and shuttering including strutting, propping etc. and removal of form for : Lintels, beams, plinth beams, girders, bressumers and cantilevers
13Centering and shuttering including strutting, propping etc. and removal of form for : Columns, Pillars, Piers, Abutments, Posts and Struts
14Centering and shuttering including strutting, propping etc. and removal of form for : Stairs, (excluding landings) except spiral-staircases
15Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level.
16Thermo-Mechanically Treated bars of grade Fe-500D or more.
17Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level.
18Thermo-Mechanically Treated bars of grade Fe-500D or more.
19Brickwork with Common Burnt clay F.P.S. (Non Modular) brick of class designation 7.5 in Foundation and Plinth in : Cement mortar 1:6 (1 Cement : 6 coarse Sand)
20Providing and laying damp-proof course 40 mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 12.5 mm nominal size derived from natural sources)
21Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level.
22Cement mortar 1:4 (1 Cement : 4 coarse Sand)
23Brick work with common burnt clay selected F.P.S. (non modular) bricks of class designation 7.5 in exposed brick work including making horizontal and vertical grooves 10 mm wide 12 mm deep complete in cement mortar 1:6 (1cement : 6 coarse sand)
24Above plinth level upto floor V level
25Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement,mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels.
26Granite stone slab colour black, Cherry/Ruby red
27Area of slab above 0.50 sqm
28Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm), with necessary accessories and screws etc. complete.
29Providing and fixing pressed steel door frames conforming to IS: 4351, manufactured from commercial mild steel sheet of 1.60 mm thickness, including hinges, jamb, lock jamb, bead and if required angle threshold of mild steel angle of section 50x25 mm, or base ties of 1.60 mm, pressed mild steel welded or rigidly fixed together by mechanical means, including M.S. pressed butt hinges 2.5 mm thick with mortar guards, lock strike-plate and shock absorbers as specified and applying a coat of approved steel primer after pre-treatment of the surface as directed by Engineer-in-charge:
30Profile B
31Fixing with adjustable lugs with split end tail to each jamb
32Providing and fixing pressed steel door frames conforming to IS: 4351, manufactured from commercial mild steel sheet of 1.60 mm thickness, including hinges, jamb, lock jamb, bead and if required angle threshold of mild steel angle of section 50x25 mm, or base ties of 1.60 mm, pressed mild steel welded or rigidly fixed together by mechanical means, including M.S. pressed butt hinges 2.5 mm thick with mortar guards, lock strike-plate and shock absorbers as specified and applying a coat of approved steel primer after pre-treatment of the surface as directed by Engineer-in-charge:
33Profile E
34Fixing with adjustable lugs with split end tail to each jamb
35Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel rimer using structural steel etc. as required.
36In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works
37Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with : 4 mm thick glass panes
38Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) :
3925 mm thick
40Kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete.
41Painting top of roofs with bitumen of approved quality @ 17kg per 10 sqm impregnated with a coat of coarse sand at 60 cudm per 10 sqm, including cleaning the slab surface with brushes and finally with a piece of cloth lightly soaked in kerosene oil complete:
42With residual type petroleum bitumen of grade VG -10
4310 cm thick (average) mud phaska of damped brick earth on roofs laid to slope consolidated and plastered with 25 mm thick mud mortar mixed with bhusa @ 35 kg per cum of earth and gobri leaping with mix 1:1 (1 clay : 1 cow dung) and covered with flat tile bricks, grouted with cement mortar 1:3 (1 cement : 3 fine sand) mixed with 2% of integral water proofing compound by weight of cement and finished neat:
44With common burnt clay F.P.S.(non modular) brick tile of class designation 10
45Poviding gola 75x75 mm in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 stone aggregate 10 mm and down gauge), including finishing with cement mortar 1:3 (1 cement : 3 fine sand) as per standard design :
46In 75x75 mm deep chase
47Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand :4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1 m x1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement, rounding the edges and making and finishing the outlet complete.
48Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes: 110 mm diameter
49Providing and fixing on wall face unplasticised - PVC moulded fittings/accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion.
50Bend 87.5° 110mm
5112 mm cement plaster of mix : 1:6 (1 cement: 6 coarse sand)
5212 mm cement plaster of mix :
531:4 (1 cement: 4 fine sand)
546 mm cement plaster of mix : 1:3 (1 cement : 3 fine sand)
55Painting with synthetic enamel paint of approved brand andmanufacture to give an even shade :
56Two or more coats on new work
57Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
58Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gram/litre, of approved manufacturer and of required shade and colour all complete to achieve even shade and colour : New work (two or more coats) over and including water thinnable priming coat with cement primer having VOC content less than 50 gram/litre.
59Providing and fixing 35mm thick phenol bounded factory manufactured solid flush door shutter ISI marked with both side commercial face in the existing chowkhat. The rate includes the cost of sliding door bolt (250X16mm), 2 nos aluminium handles 5'', SS Tower bolts 8'' & 6''all necessary Alumn fitting and painting two coats over one coat of primer after preparation of surface (special quality) complete in all respect to the entire satisfaction of Engineer-in-charge
60Providing and fixing 2'-0\\" deep cupboard /cabinet consisting of 19mm thick commercial board and 6mm thick ply on back side, 1 mm thick mica on the exposed surface and making shelves in cabinet. The rate further includes the cost of lipping, piano hinges, cupboard lock, screws, nails, 2 nos. fancy s.s. handles, 2 nos. magnetic catchers, fevicol and painting two coats over one priming coat and preparation of surface on board and ply surface complete in position as per entire satisfaction of Engineer-in-charge.
61Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. with necessary screws to the existing wooden frame including coat of synthetic enamel paint over one coat of primer complete in all respects and to the entire satisfaction of the Engineer in charge.
62Providing and fixing brick jali with class designation 10 bricks of size 22.86cm x 11.43 cm thick alternate layers laid in cement sand mortar 1:4 using 58 number bricks per sqm, compete in all respects and to the entire satisfaction of Engineer-in-charge
63Providing and fixing centre mullion member conforming to IS : 4351, manufactured from commercial mild steel sheet of 1.60 mm thickness, mild steel angle of section 50x25 mm single rebate rigidly fixed together by mechnaically means and applying a coat of primer of approved brand & manufacturrer. in all respect and entire satisfaction of Engineer-in-charge ( Profile B and E)
64Providing and fixing 35mm thick golden champ wood (kiln seasoned) glazed window shutters consisting of vertical and horizontal styles 75x35mm size with 4mm thick floated glass pane fixed with 1/2\\"x3/4\\" golden champ wood (kiln seasoned) beading. The rate further includes the cost of 2 nos. 3\\" butt hinges, 2nos Aluminium tower bolts 4\\", Aluminium handles 1 no. I-hook and two coats of special quality enamel paint over coat of primer after preparation of surface (special quality) and removal of old shutter complete in all respect to the entire satisfaction of Engineer-in-charge.
65Providing and fixing 35mm thick golden champ wood (kiln seasoned) wire gauge window shutter with vertical style & rails 75mm thick and 22 x 12 gauge wire mesh fixed with 1/2” x 3/4” beading and including 2 Nos. of 3” iron hinges ISI marked, 2 nos tower bolts 4'' And 1 no Aluminium handle 4'' and complete fixed in position including two coats of paint and one coat of primer after preparation of surface (special quality) Complete in all respect to the entire satisfaction of Engineer-in-Charge.
66Providing & fixing slate sheet roofing 10 to 12 mm thick of size 300mm X 150mm as approved by Engineer-in-Charge, in roofs oup to any pitch. the cost further includes rate of fixing the slate with special quality adhesive, jointing & pointing, scaffolding, sundries, T&P etc complete to the entire satisfaction of Engineer-In-Charge
67Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete.
68Public Health
69Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth upto 1.5 m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m : (2.10)
70All kinds of soil. (2.10.1)
71Pipes, cables etc, not exceeding 80 mm dia. (2.10.1.1)
72Pipes, cables etc. exceeding 80 mm dia. but not exceeding 300 mm dia. (2.10.1.2)
73Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources). (5.3)
74Centering and shuttering including strutting, propping etc. and removal of form for : (5.9)
75Suspended floors, roofs, landings, balconies and access platform. (5.9.3)
76Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. (5.22)
77Thermo-Mechanically Treated bars of grade Fe-500D or more. (5.22.6)
78Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : (6.4)
79Cement mortar 1:4 (1 cement : 4 coarse sand) . (6.4.1)
8012 mm cement plaster finished with a floating coat of neat cement of mix : (13.7)
811:3 (1 cement: 3 fine sand). (13.7.1)
82Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : (17.3)
83W.C. pan with ISI marked white solid plastic seat and lid. (17.3.1)
84Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required (17.10):
85Kitchen sink without drain board. (17.10.2)
86610x460 mm bowl depth 200 mm. (17.10.2.2)
87Providing and fixing white vitreous china water closet squatting pan (Indian type) : (17.13)
88Orissa pattern W.C. pan of size 580x440 mm. (17.13.2)
89Providing and fixing 8 mm dia C.P. / S.S. Jet with flexible tube upto 1 metre long with S.S. triangular plate to Eureopean type W.C. of quality and make as approved by Engineer - in -charge. (17.16A)
90Providing and fixing controlled flush, low level cistern made of vitreous china with all fittings complete. (17.19)
9110 litre (full flush) capacity-white. (17.19.1)
92Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. (17.28)
93Flexible pipe. (17.28.2)
9432 mm dia. (17.28.2.1)
95Providing and fixing soil, waste and vent pipes : (17.35)
96100 mm dia (17.35.1)
97Centrifugally cast (spun) iron socket & spigot (S&S) pipe as per IS: 3989. (17.35.1.2)
9875 mm diameter : (17.35.2)
99Centrifugally cast (spun) iron socketed pipe as per IS: 3989. (17.35.2.2)
100Providing and fixing heel rest sanitary bend. (17.40)
101100 mm dia. (17.40.1)
102Sand cast iron S&S as per IS - 3989. (17.40.1.2)
103Providing and fixing collar : (17.57)
104100 mm. (17.57.1)
105Sand cast iron S&S as per IS - 3989. (17.57.1.2)
10675 mm. (17.57.2)
107Sand cast iron S&S as per IS - 3989. (17.57.2.2)
108Providing lead caulked joints to sand cast iron/centrifugally cast (spun) iron pipes and fittings of diameter : (17.58)
109100 mm. (17.58.1)
11075 mm (17.58.2)
111Providing and fixing trap of self cleansing design with screwed down or hinged grating with or without vent arm complete, including cost of cutting and making good the walls and floors : (17.60)
112100 mm inlet and 75 mm outlet. (17.60.2)
113Sand cast iron S&S as per IS: 3989. (17.60.2.1)
114Providing and fixing G.I. pipes complete with G.I. fittings and clamps, i/c cutting and making good the walls etc. Internal work - Exposed on wall. (18.10)
11520 mm dia nominal bore. (18.10.2)
116Providing and fixing G.I. Pipes complete with G.I. fittings and clamps, i/c making good the walls etc. concealed pipe, including painting with anti corrosive bitumastic paint, cutting chases and making good the wall : (18.11)
11715 mm dia nominal bore. (18.11.1)
11820 mm dia nominal bore. (18.11.2)
119Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :(18.17)
12020 mm nominal bore. (18.17A)
121Providing and fixing uplasticised PVC connection pipe with brass unions : (18.21)
12230 cm length. (18.21.1)
12315 mm nominal bore. (18.21.1.1)
124Providing and fixing G.I. Union in G.I. pipe including cutting and threading the pipe and making long screws etc. complete (New work) :(18.46)
12520 mm nominal bore. (18.46.2)
126Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. (18.48)
127Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931 : (18.49)
12815 mm nominal bore. (18.49.1)
129Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms.(18.51)
13015 mm nominal bore. (18.51.1)
131Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931.(18.52)
13215 mm nominal bore. (18.52.1)
133Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931 (18.53)
13415mm nominal bore. (18.53.1)
135Providing and fixing C.P. Brass extension nipple (size 15mmx50mm) of approved make and quality as per direction of Engineer-in-charge.(18.53A)
136Providing and fixing PTMT Ball cock of approved quality, colour and make complete with Epoxy coated aluminium rod with L.P./ H.P.H.D. plastic ball. (18.62)
13720 mm nominal bore, 120 mm long, weighing not less than 198 gms. (18.62.2)
138Cutting holes up to 30x30 cm in walls including making good the same:( 18.76)
139With common burnt clay F.P.S. (non modular) bricks. (18.76.1)
140Cutting holes up to 15x15 cm in R.C.C. floors and roofs for passing drain pipe etc. and repairing the hole after insertion of drain pipe etc. with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), including finishing complete so as to make it leak proof. (18.77)
141Providing, laying and jointing glazed stoneware pipes class SP-1 with stiff mixture of cement mortar in the proportion of 1:1 (1 cement : 1 fine sand) including testing of joints etc. complete : (19.1)
142150 mm diameter. (19.1.2)
143Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) all-round S.W. pipes including bed concrete as per standard design : (19.2)
144150 mm diameter S.W. pipe. (19.2.2)
145Providing and fixing square-mouth S.W. gully trap class SP-1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design: (19.4)
146100x100 mm size P type. (19.4.1)
147With common burnt clay F.P.S. (non modular) bricks of class designation 7.5. (19.4.1.1)
148Constructing brick masonry chamber for underground C.I. inspection chamber and bends with bricks in cement mortar 1:4 (1 cement : 4 coarse sand) C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover with frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg), R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:5:10 fine sand : 10 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand), finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete as per standard design: (19.30)
149Inside dimensions 600x 850 mm and 45 cm deep for pipe line with three or more inlets : (19.30.3)
150With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
151Providing and fixing of C.P.steel grating hole /without hole heavy duty 100mm dia complete in all respect. (As desired by EIC)
152Providing and fixing of C.P. Brass Over Head Shower round shape 100 mm dia of approved make Round Shape SINGLE FLOW (ABS Body Chrome plated with Gray Face Plate)with RCS or equivalent complete in all respects. (As decided by the EIC)
153Providing and fixing of C.P. Brass Shower Arm casted 190 mm long of approved make round/square Shape for wall mounted showers with Wall Flange complete in all respects. (As decided by the EIC)
154Providing and fixing C.P. Brass Towel Ring of approved make complete in all respect. (As decided by the EIC)
155Providing and fixing of 600x450 or 550x400 mm beveled edge mirror of superior glass (of approved quality) complete with 5 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. (Based on DSR Item No.17.31)
156Providing and fixing in position best indian Make C.P.Cup heavy Duty Complete in all respects. (minimum weight 15gm) complete in all respects. (As desired by EIC)
157Providing and fixing of C.P. Long Bend for OWC of size 32mm dia Complete in all respect.
158Providing and fixing of C.P. brass Soap dish of approved make complete in all respects. (As desired by EIC)
159Providing and Fixing of GI Tank Nipple for fixing of tanks complete in all respects.
16020 mm
161Providing and Fixing of C.P. Brass Towel Rail 600mm long of approved make complete in all respect at site. (As decided by the EIC)
162Providing and Fixing of HCI 'P' trap 4\\" dia for OWC complete in all respect.
163Providing and fixing of C.P. brass Toilet Paper Holder of approved make complete in all respect. (As decided by the EIC)
164Providing and Fixing of Chinaware oval shape counter wash basin with C.I. brackets without pillar taps, 32mm CP brass waste of standard pattren ,including painting of fittings and brackets cutting and making good the walls whereever require make as approved by EIC. (As decided by the EIC)
165Providing and Fixing white vitreous china flat back half stall urinal of size 420x395x635mm with fittings, standard size C.P. brass flush pipe, spreaders with unions and clamps (all in C.P. brass) with waste fitting as per IS:2556, C.I. trap with outlet grating and other couplingts in C.P. brass, including painting of fittings and cutting and making good the walls and floors whereever required: (As decided by the EIC)
166Providing and fixing of C.P. brass Autocloset pressmatic urinal cock of approved make complete in all respect. (As decided by the EIC)
167Providing and fixing of C.P. brass Pillar Cock with autoclosing system of approved make complete in all respect. (As decided by the EIC)
168Fire Fighting
169Supply, installation, testing and commissioning ISI marked (IS:15683) Fire Extinguisher, Carbon-di-oxide type capacity 4.5 Kg. Flat base including valve, discharge hose of not less than 10 mm dia, 1M long and complete in all respects including initial fill with CO2 gas conforming to IS:307-1966 and walll suspension braket as required as per specifications. Make: As per approved make list attached.
170Supply, installation, testing and commissioning of 6 kg ABC (Powder Type) Fire Extinguisher. Mild Steel Cylinders ISI marked fitted with pressure indicating gauge, internal tube, squeeze lever type valve fully charged with ABC 90 powder (Mono Ammonium Phosphate) pressured by Nitrogen complete in all respects including wall suspension bracket and conforming to IS:15683 as required as per specifications. Make: As per approved make list attached.
171Supplying , Installation, Testing and Commissioning of Air Cooled Hi Wall split type Air conditioners complete with Indoor unit(IDU), Out door unit (ODU), surface / concealed copper Refrigerant piping with insulation (closed cell elastomeric nitrile rubber tubular pipe section) upto 3 Mtr (IDU to ODU), copper power cable upto 3.5 Mtr (IDU to ODU) i/c drain pipe R-32/R-410/ R-407 Green Refrigerant, wireless Remote control, suitable for working between 180- 260V with low & high voltage cutoff and 50 hz ,1 phase AC supply capable of performing cooling, dehumidification, air circulation of following capacity with Scroll / rotary compressor. The system shall be able to deliver 100% of the rated capacity upto 42 0C. Min 5 year Original Equipment Manufacturer (OEM) warranty both compressor and Printed Circuit Board (PCB). Must comply : Electrical cable IS 694 or IS 9968 temperature sensing control IS /International Electrotechnical Commission (IEC) 60730, hermetic compressor IS 10617, heat exchanger IS 11329, capacitor IS 2993 and motor IS 12615. Complete as per CPWD specification and IS : 1391 Part II 2023. The system shall be able to operate up to 50 0C (out door ambient temperature). Make: Carrier, Daikin, Mitsubishi, Hitachi, Voltas, Bluestar, Toshiba
172Inverter Type - Cooling only
1731.5 TR with 5 Star BEE Rating
174Providing and Fixing of powder coated readymade stand for out door stand for split outdoor as per site requirement to the entire satisfaction of EIC..
175Drain Pipe : Providing and Fixing of PVC rigid drain of 3/4\\" i/d including the cost of clamping and chasing through walls and making good the same in original condition. Make : Displast, Supreme, Prince.
176Refrigerant Piping : Providing and Fixing of 22 gauge soft copper piping of size 3/8” & 5/8” or as per original manufacturer of A/C size, for Liquid & Suction sides, between indoor & outdoor units with 6 mm thick nitrile rubber insulation & protective covering for exposed whether/chasing including cost of chasing brick wall/RCC wall & repairing to original condition. The rate per meter includes cost of 1 meter each of both 3/8” & 5/8” with insulation.
177Providing and fixing of copper wire of size 3 core 2.5 sqmm for electrical connection to A.C. units. Make : Ecko, L&T, Havells
178Providing and Fixing of Voltage Stablizer Copper Winding Range 160-280 Volt with Timer, MCB, Voltmeter, Amp Meter/ Digital Display Meter & 22 G powder coated body/ fiber body with fire retartent complete in all respects to the entire satisfaction of EIC. Make: V-Guard, Deol, Microtech, Luminous
1794 KVA
180Electrical Item
181DSR item 1.3 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.
182Group B
183DSR item 1.4 Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc. as required.
184DSR Item No.1.17 Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required.
1853x1.5 sq.mm
1863 x 2.5 sq. mm
1873 x 4 sq. mm
188DSR Item No.1.21 Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.
18925 mm
190DSR Item No. 1.24 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.
191Telephone socket outlet
192DSR Item No.1.38 Supplying and fixing call bell/ buzzer suitable for single phase, 230 volts, complete as required.
193DSR item No.1.31 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required.
194DSR item No.1.32 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 A & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required.
195DSR 1.33 Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required.
196DSR 2.10 Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
197Single Pole
198Triple Pole
199DSR 1.57 Supplying & fixing suitable size GI box with modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, \\"C\\" curve including connections, painting etc. as required.
200DSR 5.2 Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required.
201DSR item No.5.12 Providing and laying earth connection from earth electrode with 6 SWG dia G.I. Wire in 15 mm dia G.I. pipe from earth electrode including connection with G.I. thimble excavation and re-filling as required.
202DSR item 11.1 Supplying and making end termination with brass compression gland and aluminum lungs for following size of PVC insulated and PVC sheathed / XLPE aluminum conductor cable of 1.1 KV grade as required.
2033½ X 35 sq. mm (32mm)
2044 X 10 sq. mm (25mm)
205Civil DSR 10.18 Providing and fixing circular/ Hexagonal cast iron or M.S. sheet box for ceiling fan clamp, of internal dia 140 mm, 73 mm height, top lid of 1.5 mm thick M.S. sheet with its top surface hacked for proper bonding, top lid shall be screwed into the cast iron/ M.S. sheet box by means of 3.3 mm dia round headed screws, one lock at the corners. Clamp shall be made of 12 mm dia M.S. bar bent to shape as per standard drawing.
206DSR Item No.15.15 Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. in the existing trench, complete as required.
20763 mm dia (OD-63 mm & ID-51 mm nominal)
208DSR item No.14.16 Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required.
20963 mm dia (OD-63 mm & ID-51 mm nominal)
210DSR 9.1 Brush Less Direct Current (BLDC) Fan with RemoteSupply, Installation, Testing and Commissioning of ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. metal(Aluminium alloy) blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, steel/Al body. Power Factor not less than 0.9, Service Value (CM/M/W) minimum as below, 350 RPM (tolerance as per IS : 374-2019), THD (Total Harmonic Distortion) less than 10%, remote (preferably mobile app based) for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 0C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC supply Ceiling Fan compliant to IS 374:2019 fan i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required. 1200mm, service value ≥ 6.0 CM/Min/Watt, air delivery 210 CM/Min (Minimum)
2111200mm, service value ≥ 6.0 CM/Min/Watt, air delivery 210 CM/Min (Minimum)
212DSR Item No. 2.5: Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer) as required. (Note: Vertical type MCB TPDB is normally used where 3 phase outlets are required.)
2138 way (4 + 24), Double door
214Supply & erection of Exhaust Fan (heavy duty motor with copper wound metallic body) following size complete with motor, metallic blades, double ball bearing with minimum power consumption, rigid frame with rubber mounting for silent operation, epoxy powder coating along with metallic louver to be installed in the existing opening including cost of making the hole to suit the size of above fan making good the damage, Carriage Charges connection, testing, commissioning etc. as required to complete the job to the entire satisfaction of Engineer-in-charge.
215Size 15 inches (380mm) Sweep, 900 RPM Heavy Duty Exhaust fan (Single Phase) with louver of Havells (Turbo Force SP) / Orient (Industrial Heavy Duty)/ Usha (Turbo HDEF)/ Crompton (EXHD380-6-1)/ Bajaj (Supreme Plus) make only.
216Supply & erection of Wall Fan 400mm sweep oscillating type complete with blades with regulator. The fan should be of Havells (Swing)/ Usha (MAXX AIR)/ Orient (400mm Wall44)/ Crompton (WM Hiflo wave)/ Bajaj (Esteem Double String) make only. The wall fan should be provided with double string i.e. one no. controlling oscillating and one for speed. The cost including connection with adjacent light points with the help of suitable rating copper wire.
217DSR 8.7 LED Panel light 2x2 ft. (System lumen efficacy ≥120 <135 lm/Watt)Supplying, Installation, Testing & Commissioning of Panel light 2x2 ft., of following body material and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range -5 0C to 40 0C, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80, UGR (Unified Glare Rating) <19, Flicker free, (flicker should be below 5 %), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with , 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard. Manufactures Word Mark/ Name Engraved/Embossing/ Screen printing on housing. Complete in all respect i/c external connections with 1.5 sqmm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 <135 lm/Watt output .LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). Powder Coated CRCA Sheet Body (Thickness > 0.50 mm)36 watt
218DSR item no. 8.10LED Batten light (System lumen efficacy ≥120 <135 lm/Watt) Supplying, installation, Testing & Commissioning of LED surface mounted Batten light of following body material and construction as per IS : 10322 with driver (Replaceable) as per the requirement with Driver efficiency >85% ,Operating voltage AC 140-270 Volt, freq 50/60 hz, Operating temp range -15 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80, Flicker free, (flicker should be below 5 %), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with , 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard and trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output . LM79 & LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C).Powder Coated CRCA Sheet Body (Thickness >0.50 mm)18-22 watt
219DSR item no.8.16 LED Flood Light, powder coated pressure die cast aluminium (System lumen efficacy ≥120 and <135 lm/Watt) Supplying, installation, Testing & Commissioning of Flood Light, powder coated pressure die cast aluminium body with built in or separate driver as per the requirement with Driver efficiency >85%, Input voltage: Input voltage: 140-270 Volt AC, freq 50/60 hz, Operating temp range -5 deg to 50 deg centigrade, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2, P. F.≥0.95, IP-66,IK-10, CRI >70, under voltage and over voltage protection, EMI-EMC as per CISPR-15, lenses for beam angle 30 deg-120deg as per the application and the project requirement deg, suitable tilt able fitting, life time (LED, Driver & electrical circuitary) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 and <135 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size andCCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminum housing such that LED junction temperature shall not rise above 90°C).
22050 watt
221S/E of LED Bulk Head Luminaries weather proof frosted light with PMMA / PC reflector and silicon gasket to be installed on surface. The LED fitting should have minimum system Lumen output minimum 1000 Lumen and the driver of the fitting should be workable on 140-260 Volt. The colour temperature of LED should be minimum 5000 degree Kelvin. The LED Bulk Head fitting should be of Philips / Wipro / Bajaj /Crompton / Havells / Jaquar make only. The fitting should be of IP-65/66. The LED should have a life of 50000 burning Hours. The fitting should have THD<10% and power factor 0.9 or above. The job includes the cost of testing, commissioning and making connection with copper wire from adjacent light point, other petty material and labour etc. as required to complete the same to the entire satisfaction of Engineer-in -Charge.
222Supply and fixing of 12 modules (200 mm x 150 mm) G.I box suitable for accommodate the following accessories along with modular base and cover plate for modular switches in recess / surface etc as required for Computer Point with 4 Nos. 5/6 Amp. modular switch and 4 Nos. 3 pin 5/6 Amp. modular socket outlet. The job includes the cost of making interconnections with suitable copper wire, painting of box with approved paint and other petty material required to complete the job to the entire satisfaction of Engineer-in-Charge at site. The Modular accessories should be of Goldmedal (Gifa) / L&T (Oris) / ABB (Ivie) / Legrand (Arteor) / Crabtree (Athena) make only.
223Supply and erection of MS bracket F type suitable size and suitable shape made form 40mm x 40mm x 5mm thick angle iron to be installed on exiting parapet/ wall with help of suitable size of nuts and bolts etc. for erection of existing LED flood light fittings. The job also includes the cost of painting of box with superior quality of paint and other petty material etc as per required to complete the job.
224Supply & fixing of OEM made Junction box IP-66/67 made out of Polycarbonate with Glass fiber reinforced of size 130x180x77 (minimum) with 5 nos. OEM made connectors/ terminal blocks. The Jn. Box and connectors/ terminal blocks should be supplied by OEM. The terminal blocks/ connectors should be of Hensel/ Wago/ Elmax/ Siemens make only and junction box shall be of Hensel make KF-1616 G or its equivalent Clipsal/ Legrand/ Rittal/ Schneider/ ABB make only. The Junction box shall be fire retardant and self-extinguishing. The gasket material shall be polyurethane and the gasket shall be internally embedded. The job includes the cost of cable glands for cable entry, mounting kit for pipe and post installation, fixing screw, all labour and petty material required to complete the job to the entire satisfaction of the Engineer in Charge of work.
225Labour charges for horizontal boring by mechanical means (hydraulic excavator)/ manual means 1 Meter below the ground level for laying of DWC Pipe including cost of 2 nos. Pit digging and refilling, disposal earth to be leveled and neatly dressed complete in all respects to entire satisfaction of the Engineer in Charge of the work.
226Supply and laying of XLPE insulated PVC sheathed Aluminum conductor armoured cable of 1.1 KV grade as per IS 7098 (Part-I) 1988 (amended up to date) of the following sizes to be laid in existing Trench/Ducts/Cable Tray/ RCC/ HUME/ METAL/ DWC pipe / on surface with the help of MS clamps of suitable size/ as required at site to the entire satsfaction of Engineer-in-Charge. The job includes labour charges of laying the cable and making connections with suitable size aluminum lugs/thimbles etc. The cable shall be of Polycab / Havells / R.R. Kabel/ KEI/ Finolex/Grandlay make only.
227Size 10 sq.mm 4 core. (on surface)
228Size 35 sq.mm 3.5 core. (in pipe)
229DSR item no.8.2LED Down lighter (SMD Type) (System lumen efficacy ≥120<135lm/Watt) Supplying, installation, Testing & Commissioning of LED Recessed/surface Down lighter (Round/ square/ Rectangular) SMD type of following body material with PMMA and prismatic diffuser and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range -5 0C to 40 0C centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10%, P. F.≥0.95, IP20, CRI >80, UGR (Unified Glare Rating) <19, Flicker free (flicker should be below 5 %), life time (LED, Driver & electrical circuitry), life time of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing Complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 <135 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted.. Shape size and CCT shall be as approved by Engineer-in- Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). Powder coated die cast /Extruded aluminium Body including trim .
23018 watt
231DSR 2.2 Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, Ics=100% Icu and Operational Voltage 690V etc. as required.100 A,30KA,FPMCCB
232S/E of MCCB enclosure 63/100 amp. The job includes all labour & petty material required to complete the job in entire satisfaction of EIC. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 58037106
AUTHORITY Local Bodies
TENDER VALUE 5.19 Crore
LAST DATE 21-10-2026
Authority
Authority Name Chandigarh Administration Engineering Department
Work Description Tender for Construction Of 15 Nos. Security Check Post At Naya Gaon, Jayanti Majra, Mullanpur Barrier, Sarangpur Barrier, Togan Barrier, Makhanmajra, Raipur Kalan, Dhillon Barrier, Kishangarh, Zirakpur Barrier, Faidan Barrier, Mohali Barrier, Badheri Barrier Naka At Dividing Road 55/56, Jh Ur Barrier, Chandigarh.
Basic Detail
Tender No CP6/2026/1976-1989/checkpost
Bidding Type Tender
Location
City Chandigarh
State Chandigarh
Key Dates
Publish Date 14 Oct 2026
Submission Date 21 Oct 2026
Open Date 21 Oct 2026
Finance
Tender Value 5.19 Crore
Tender Fee Ref. Documents
EMD 10.38 Lakhs
Exemption Not Available
Document List
1ad47f0e-0cf5-4232-890f-a0808d98b0ff.html
BOQ_118208.xls
Tendernotice_1.pdf
Tendernotice_2.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Oct 14, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Oct 21, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 6 days
Oct 21, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 6 days

Tender Documents

Download All (ZIP) ↓
html

1ad47f0e-0cf5-4232-890f-a0808d98b0ff.html

xls

BOQ_118208.xls

pdf

Tendernotice_1.pdf

pdf

Tendernotice_2.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender