Housing Urban and Rular Development Government Departments Closing in 13 days TDR #58036906

Tender For Repair And Renovation Of Two Storied 3(Three) Nos Doctors Quarters 2(Two) Storied 4(Four) Nos Nurses Quarters And Bmoh Quarter At Salar Rh Under Bharatpur -Ii Block, Murshidabad.

Issued by Government Departments · Murshidabad, West Bengal
Tender Value
Ref. Documents
Estimated cost
Bid Submission
30 Oct 2026
13 days left
EMD
27844
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Murshidabad → West Bengal
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Repair And Renovation Of Two Storied 3(Three) Nos Doctors Quarters 2(Two) Storied 4(Four) Nos Nurses Quarters And Bmoh Quarter At Salar Rh Under Bharatpur -Ii Block, Murshidabad.

BOQ

Name of Work:- Repair and Renovation of two storied 3(three) nos Doctors Quarters 2(two) storied 4(four) nos nurses Quarters and BMOH Quarter at Salar RH under Bharatpur -II block, Murshidabad.
Sl. No. Item Description
1Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, inter connections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 16 way , Double door -LEGRAND/SCHNIDER/ABB/SEIMENS/L&T
2Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit, with piano type switch, phenolic laminated sheet, suitable size M.S. box and earthing the point with 1.5 sq.mm. FRLS/HFFR PVC insulated copper conductor single core cable etc. as required. -GROUP-A
3Supplying and fixing metal box of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc. as required.
4100 mm X 100 mm X 60 mm deep
5150 mm X 150 mm X 60 mm deep
6180 mm X 100 mm X 60 mm deep
7200 mm X 125 mm X 60 mm deep
8Supplying and fixing following piano type switch/socket on the existing switch box/ cover including connections etc. as required.
95/6 amps switch
1015/16 A switch
113 pin 5/6 A socket outlet
126 pin 15/16 A socket outlet
13Bell push
14Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required.
15Supplying and fixing brass batten/ angle holder including connection etc. as required.
16Supplying and fixing call bell/ buzzer suitable for single phase, 230 V, complete as required.
17Supply&Fixing Socket type fan regulator (Step type) (Brand appro ved by EIC) on existing sheet metal switch board with bakelite/persp ex top cover by screw after making housing for regulator knob by cut ting bakelite/perspex top cover incl. making necy. connections etc
18S &F of energy saver LED Lamp 18W-20W 200V-240V, 50Hz (Make -Philips/WIPRO/ORIENT/CROMPTON/HAVELLES
19S & F Bulk head light fitting (Havells Make)
20Supplying & Fixing GI waterproof type looping cable box size 200x150 x100 mm deep having 4 mm thick comprising of one 250V 15 A kit-kat fuse unit, one NL on porcelain insulator, onecompression type brass cable gland for upto 2- core 16 sqmm PVC/A cable and having lined with rubber gasketted GI top cover with brass machine screws etc., earthing terminal with lug, on steel tubular pole near base, including S&F 40x6 mm thick, MS clamps with bolts, nuts etc. including painting with anticorrosive paint (Make-Syntex)
21LED Street light fixture, powder coated pressure die cast alumin ium body (System lumen efficacy ≥105 <120 lm/Watt
22Supplying, installation, Testing & Commissioning of Street light LED fixture powder coated pressure die cast aluminium body with driver as per the requirement with Driver efficiency >85%, Inp ut voltage: 140-270 Volt AC, frequency 50/60 hz, Operating temp range -5 0C to 50 0C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2, P. F.≥0.95, IP-66,IK-10, CRI >70,under voltage and
23over voltage protection, EMI EMC As per CISPR -15, lenses for beam angle as per IESNA type I/II/III as per the width of the road and the project requirement., suitable to fit in up to 65mm dia pipe, life time (LED, Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin),SDCM (Standard Deviation Colour Matching) <5, Maximum power consumption
24should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connec tions with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conduct or single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output .LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). (50 watt)
25Supplying and fixing following rating, double pole, 240V, isolator in the existing MCB DB complete with connections,testing and commissi oning etc. as required. A) 63 A DP
26Supplying and fixing 5 A to 32 A rating, 240/415 V, 10kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
27Single pole
28Single pole and neutral
29Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required.
30Supplying and fixing DP sheet steel enclosure on surface/recess along with 25/32 A 240 V \\"C\\" curve DP MCB complete with connections, testi ng and commissioning etc. as required.
31Supply & Fixing 240 V, 25 A, Modular type starter (Brand approved by EIC) with 25A Modular switch type DP MCB (C Curve) and 4 Module GI Modular type switch board with 4 Module top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc .
32Supply & Fixing 240 V, 25 A, 3 pin Modular type plug top with indicator ( Brand approved by EIC ) & necy. Connections
33Supplying of one number 1.1 KV Grade XLPE insulated and PVC sheathed aluminium conductor cable ( Armoured ) Al cable conforming to IS: 7098 / 1988 with its latest amendment of following size. [ Make RR KEBEL / Fort Gloster/Polycab/Havells]
342 Core 10 sqmm XLPE Ar/ AL Cable
35Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required.
36Upto 35 sq. mm (clamped with 1mm thick saddle)
37Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.
382 X 10 sq. mm (19mm)
39Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required.
40Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in surface/recessed medium class PVC conduit as required.
412 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire
422 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
432 X 4 sq. mm + 1 X 4 sq. mm earth wire
44S & F 250V 25A Timer controller for AC machine in SS double door 2+10-way DB enclosure (Make:- L&T, encloser cat no DBSPN012DD) or equv alant) with S&F following electrical accessories & front door locking arra ngement with all connection by finishing the ends of 2x4 & 1x2.5 copper wire dowells solderless socket by crimping method as to GS earthing attachment on wall incl necessary connections as per direction of EIC :-i)10kA,C-Curve, 240V, 25A ,DPMCB (LT/Schnider/ABB Elegance) -1 Noii) 24 Hr programmable Digital/Analog Timer (LT make cat no 67DDT0) - 1 Noiii) 3 pole power contractor (LT make cat no MNX 22/230V) with 1 NO +1 NC additional contact block ---- 1 setiv) 2 Moduler AC motor stater (Make:- Legrand/Myrius) ---- 1 No.v) 2 Module plate with cover (Make :- Legrand/Myrius) -- 1 Novi) 20A Auto-Off-Bipass SPDT toggle switch (Approved/reputed make) ---- 1 No.vii) 10A SPST Moduler type switch (Make :- Legrand/Myrius) - 1 No.viii)Outgoing connector make ELMAX (Approved/reputed make) - 1 No- LEGRAND/SCHNIDER/ABB/SEIMENS/L&T Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 58036906
AUTHORITY Government Departments
TENDER VALUE Ref. Documents
LAST DATE 30-10-2026
Authority
Authority Name Public Works Department
Work Description Tender for Repair And Renovation Of Two Storied 3(Three) Nos Doctors Quarters 2(Two) Storied 4(Four) Nos Nurses Quarters And Bmoh Quarter At Salar Rh Under Bharatpur -Ii Block, Murshidabad.
Basic Detail
Tender No WBPWD/EE/MsdED/138/e-Q of 26-27
Bidding Type Tender
Location
City Murshidabad
State West Bengal
Key Dates
Publish Date 14 Oct 2026
Submission Date 30 Oct 2026
Open Date 02 Nov 2026
Finance
Tender Value Ref. Documents
Tender Fee Ref. Documents
EMD 27844
Exemption Not Available
Document List
8b49a551-21d2-4dd3-9aad-882d3477db52.html
BOQ_5187357.xls
Tendernotice_1.pdf
Tendernotice_2.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Oct 14, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Oct 30, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 13 days
Nov 02, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 16 days

Tender Documents

Download All (ZIP) ↓
html

8b49a551-21d2-4dd3-9aad-882d3477db52.html

xls

BOQ_5187357.xls

pdf

Tendernotice_1.pdf

pdf

Tendernotice_2.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender