Agriculture Government Departments Closing in 16 days TDR #58036855

Tender For Civil Work For Construction Of ‘Fodder Storage Godown Dry And Green Dual Purpose At The Keshiary Milk Chilling Plant Complex, Dudhebudhe, Keshiary, Paschim Medinipur, West Bengal, Pin-721133

Issued by Government Departments · Medinipur West, West Bengal
Tender Value
18.26 Lakhs
Estimated cost
Bid Submission
31 Oct 2026
16 days left
EMD
37000
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Medinipur West → West Bengal
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Civil Work For Construction Of ‘Fodder Storage Godown Dry And Green Dual Purpose At The Keshiary Milk Chilling Plant Complex, Dudhebudhe, Keshiary, Paschim Medinipur, West Bengal, Pin-721133

BOQ

Name of Work:- Civil work for construction of ‘Fodder Storage Godown Dry and Green Dual Purpose at the Keshiary Milk Chilling Plant Complex, Dudhebudhe, Keshiary, Paschim Medinipur, West Bengal, PIN-721133
Sl. No. Item Description
1Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and for all lift, as directed by Engineer-in-charge. All kinds of soil
2Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 and for all lift.
3Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete.
4Dry brick pitching half brick thick in drains including supply of bricks and preparing the surface complete : With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
5Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:3:6 (1 Cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources)
6Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources)
7Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources)
8Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources)
9Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources).
10Centering and shuttering including strutting, propping etc. and removal of form for- a) Foundations, footings, bases of columns, etc. for mass concrete
11Centering and shuttering including strutting, propping etc. and removal of form for- b) Lintels, beams, plinth beams, girders, bressumers and cantilevers
12Centering and shuttering including strutting, propping etc. and removal of form for- c) Columns, Pillars, Piers, Abutments, Posts and Struts
13Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more.
14Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : Cement mortar 1:6 (1 cement : 6 coarse sand)
1520 mm cement plaster of mix : 1:6 (1 Cement: 6 coarse sand)
1615 mm thick plaster on rough side of single or half brick wall of mix: 1:6 (1 Cement: 6 coarse sand).
17Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete. 40 mm thick with 20 mm nominal size stone aggregate (a) In Ground Floor
1815 mm thick plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix: 1:4 (1 Cement: 4 fine sand)
19Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gram/litre, of approved manufacturer and of required shade and colour all complete to achieve even shade and colour : New work (two or more coats) over and including water thinnable priming coat with cement primer having VOC content less than 50 gram/litre
20Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade: New work (Two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm).
21Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade : Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture
22Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.
23Providing and fixing 1 mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. Using M.S. angels 40x40x6 mm for diagonal braces
24Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters. 80x1.25 mm M.S. laths with 1.25 mm thick top cover
25Providing corrugated G.S. sheet roofing including vertical / curved surface fixed with polymer coated J or L hooks, bolts and nuts 8 mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead, including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete (up to any pitch in horizontal/ vertical or curved surfaces), excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. 0.63 mm thick with zinc coating not less than 275 gm/ m²
26Providing ridges or hips of width 60 cm overall width plain G.S. sheet fixed with polymer coated J or L hooks, bolts and nuts 8 mm dia G.I. limpet and bitumen washers complete. 0.63 mm thick with zinc coating not less than 275 gm/m²
27Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator). 4 way (4+12), Double door
28Supplying and fixing 12 way, Double door, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)(As per direction of EIC & Brand approved by EIC)
29Supplying and fixing following rating, double pole, 240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.(As per direction of EIC & Brand approved by EIC). 40 A DP
30Supplying and fixing following rating, four pole, 415 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. 63A FP
31Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, 'C' curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single Pole
32Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, 'C' curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Triple pole (32A)
33Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq mm FRLS/HFFR PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq mm FRLS/HFFR PVC insulated copper conductor single core cable etc as required as per direction of EIC and brand approved by EIC (Group C)
34Distn wiring in 22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire(Brand approved by EIC) in 19 mm bore, 3 mm thick polythen pipe complete with all accessories embedded in wall to 240 V 6A 5 pin plug point incl. S&F 240 V 6A 3 pin Modular type plug socket & Modular type switch (Brand approved by EIC) incl S&F earth continuity wire, fixed on 4 Module GI switch board with 3/4 Module top cover plate flushed in wall incl. mending good damages to original finish 2x22/0.3 (Ph & N) and 1x22/0.3 as ECC (On Board)
35Supplying, installation, Testing & Commissioning of LED surface mounted Batten light of following body material and construction as per IS : 10322 with driver (Replaceable) as per the requirement with Driver efficiency >85%, Operating voltage AC 140- 270 Volt, frequency 50/60 hz, Operating temp range -5 0C to 40 0C, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P.F.≥0.95, IP20, CRI >80, Flicker free (flicker should be below 5 %), life time (LED,Driver & electrical circuitry), of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Colour Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard. Manufactures Word Mark/ Name Engraved/Embossing/ Screen printing on housing. complete in all respect i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 <135 lm/Watt output .LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). Powder coated die cast /Extruded aluminium Body (Thickness > 1.20 mm) LED Batten light 36 watt (System lumen efficacy ≥120<135 lm/Watt) [As per direction of EIC and brand approved by EIC]
36Supplying and fixing PVC batten/ angle holder including connections etc. as required.
37Supply and fixing 9 Watt 825 lm LED bulb. [Make:- Philips/Havells/Crompton]
38Fixing only bulk head ceiling fitting on wall /ceiling by screws etc.
39Supplying LED bulk head light fitting (Philips cat no.-WT202W LED6S NW PSU S2 PC/ CG cat no.- LBHE-10-CDL)
40Providing and fixing circular/Hexagonal G.I. Box for ceiling fan clamps, of internal dia 140 mm, 73 mm height, top LID of 1.5 mm thickG.I. sheet with its top surface hacked for proper bonding, top LID shall be screwed into the G.I. box by means of 3.3 mm dia rounded screws, one lock at the corners. Clamps shall be made of 12 mm dia M.S. bar bent to shape as per standard drawing.
41Supply, Installation, Testing and Commissioning of ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation B, 3 nos metal(Aluminium alloy) blades, 30 cm long down rod, 2 nos canopies, shackle kit, safety rope, copper winding, steel/Al body Power Factor not less than 0.9, Service Value (CMM/W) minimum as below, 350 RPM (tolerance as per IS 374:2019), THD (Total Harmonic Distortion) less than 10%, suitable for operation with regulator for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 °C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC supply, Ceiling Fan compliant to IS 374:2019 fan i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required [As per direction of EIC and brand approved by EIC] 1200mm, service value >= 6.0 CM/Min/Watt, air delivery 210 CM/Min (Minimum)
42Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. [As per direction of EIC and brand approved by EIC]
43Installation, testing and commissioning of exhaust fan up to 450 mm in the existing opening including making good damage, connection, testing and commissioning etc. as required.
44Extra for fixing louvers/shutters complete with frame for exhaust fan of all sizes.
45Supply & Delivery 9 inch (230mm), 1370 RPM, 40 Watt heavy-duty AC exhaust fan incl. regulator/all connections. [Make-EPC/Usha/Orient Electric]
46Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6-pin 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required [As per direction of EIC and brand approved by EIC]
47Supply & Fixing 240 V, 4 nos. 6 A, 3 pin Modular type plug socket with 4 nos. 6A Modular type switch (Brand approved by EIC), 16A Modular switch type MCB (C-Curve) and Indicator without plug top on 2 row 18 Module GI Modular type switch board with 2 row 18 Module top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc.
48Supplying and fixing 6 modules, GI box along with modular base & cover plate incl. Supplying and fixing 1 no. 5/6 A, 1 nos. 15/16 A modular switch & 1no. 3 pin 5/6 A & 1 nos. 6 pin 15/16 A modular type socket outlet on the existing modular plate & switch box including connections but excluding modular plate etc. as required for modular switches in recess etc as required. (As per direction of EIC & Brand approved by EIC)
49Supplying and fixing 2 modules, GI box along with modular base & cover plate incl. Supplying and fixing 16A modular switch on the existing modular plate & switch box including connections but excluding modular plate etc. as required for modular switches in recess etc. as required. (As per direction of EIC & Brand approved by EIC)
50Supplying and fixing 2 modules, GI box along with modular base & cover plate incl. Supplying and fixing 16A modular switch on the existing modular plate & switch box including connections but excluding modular plate etc. as required for modular switches in recess etc. as required. (As per direction of EIC & Brand approved by EIC)
51Supply & Fixing 240 V, 25 A, 3 pin Modular type plug socket (Brand approved by EIC), without plug top and switch with 2 Module GI Modular type switch board with top cover plate flushed in wall and making necy. connections with PVC Cu wire and earth continuity wire etc.
52Supply & Fixing 240 V, 25 A, 3-pin modular type plug top with indicator (Brand approved by EIC) and necessary connections.
53Supplying and fixing metal box of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc. as required. 150 mm X 150 mm X 60 mm deep
54Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in surface/recessed medium class PVC conduit as required. (As per direction of EIC & Brand approved by EIC) 2 x 1.5 sq.mm + 1 x 1.5 sq.mm earth wire
55Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in surface/recessed medium class PVC conduit as required. (As per direction of EIC & Brand approved by EIC) 2 x 2.5 sq.mm + 1 x 2.5 sq.mm earth wire
56Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in surface/recessed medium class PVC conduit as required. (As per direction of EIC & Brand approved by EIC) 2 x 4 sq.mm + 1 x 4 sq.mm earth wire
57Finishing of the PVC insulated wire ends by socketting with pin/ ring type copper sockets and insulated tapes etc., including supplying sockets, tapes. 1.5 sqmm
58Finishing of the PVC insulated wire ends by socketting with pin/ ring type copper sockets and insulated tapes etc., including supplying sockets, tapes. 2.5 sqmm
59Finishing of the PVC insulated wire ends by socketting with pin/ ring type copper sockets and insulated tapes etc., including supplying sockets, tapes. 4 sqmm
60Earthing with G.I. earth pipe 4.5 Meter long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required.
61Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including G.I. nut, bolt, spring washer and jointing; from earth pit to earth bus bar for body earthing.
62Supplying & fixing earth busbar of galvanized (Hot Dip) MS flat 40 mm x 6 mm on wall having clearance of 6 mm from wall including providing drilled holes on the busbar complete with GI bolts, nuts, washers, spacing insulators etc. as required.
63Supplying & Fixing PVC waterproof type looping cable box(SINTEX/As per EIC) size minimum 200x150x100 mm deep comprising of one 250 V 15 A kit-kat fuse unit, one NL on porcelain insulator, two provision of compression type brass cable gland for upto 4- core 16 sqmm PVC/A cable and having lined with rubber gasketted top cover with brass machine screws etc., earthing terminal with lug, on steel tubular pole, including S&F 40x6 mm thick, suitable \\"C\\" type 4mm thick MS clamps with bolts, nuts etc. including painting with anticorrosive paint.
64Supplying and delivery of following size Armoured cables XLPE/PVC insulated are designed for 1.1 kV Stranded Aluminium conductor, high tensile galvanized steel wire/strip armour for mechanical protection, and PVC/FR PVC outer sheathing power cable of following size. (IS 7098 Part - 1/2011 with Up To Date Amendments.) 2 core 10 sqmm (Make-polycab/Havells/Gloster)
65Supplying and delivery of following size Armoured cables XLPE/PVC insulated are designed for 1.1 kV Stranded Aluminium conductor, high tensile galvanized steel wire/strip armour for mechanical protection, and PVC/FR PVC outer sheathing power cable of following size. (IS 7098 Part - 1/2011 with Up To Date Amendments.) 4 core 70 sqmm (Make-polycab/Havells/Gloster)
66Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required. 2 core 10 sqmm (clamped with 1mm thick saddle)
67Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required. 4 core 70 sqmm (Make-polycab/Havells/Gloster) (clamped with 25x3mm MS flat clamp)
68Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 2 core 10 sqmm
69Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 4 core 70 sqmm
70Deduction for Correction on Total amount of Item No.-1 to Item No.- 69
71Enhancement for Cost index for West Midnapore on Total amount of Item No.-1 to Item No.-70 Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 58036855
AUTHORITY Government Departments
TENDER VALUE 18.26 Lakhs
LAST DATE 31-10-2026
Authority
Authority Name Animal Resources Development Department
Work Description Tender for Civil Work For Construction Of ‘Fodder Storage Godown Dry And Green Dual Purpose At The Keshiary Milk Chilling Plant Complex, Dudhebudhe, Keshiary, Paschim Medinipur, West Bengal, Pin-721133
Basic Detail
Tender No MU/e-Tender/02/26-27/ 373
Bidding Type Tender
Location
City Medinipur West
State West Bengal
Key Dates
Publish Date 14 Oct 2026
Submission Date 31 Oct 2026
Open Date 03 Nov 2026
Finance
Tender Value 18.26 Lakhs
Tender Fee Ref. Documents
EMD 37000
Exemption Not Available
Document List
7cd5c197-ca77-4383-83b3-944d715811ad.html
BOQ_2564197.xls
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Oct 14, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Oct 31, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 16 days
Nov 03, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 19 days

Tender Documents

Download All (ZIP) ↓
html

7cd5c197-ca77-4383-83b3-944d715811ad.html

xls

BOQ_2564197.xls

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender