Water Resources and Irrigation Government Departments Closing in 5 days TDR #58036793

Tender For General-Keri- Hydraulics Division-Electrification Works Of Hydraulics Division Office-General Electrical Work

Issued by Government Departments · Thrissur, Kerala
Tender Value
2.70 Lakhs
Estimated cost
Bid Submission
23 Oct 2026
5 days left
EMD
6770
Bank guarantee accepted
Document Fee
600
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Thrissur → Kerala
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for General-Keri- Hydraulics Division-Electrification Works Of Hydraulics Division Office-General Electrical Work

BOQ

Name of Work:- GENERAL-KERI- Hydraulics Division-Electrification works of Hydraulics Division office-General Electrical Work
Sl. No. Item Description
1Electrification
2OD148167/2026-2027:SITC of 2 kVA, without isolation transformer type, online UPS having 30 minute backup, connecting in stand-alone configuration with the following specification. a) input PF: 0.99 @ full load b) output PF: 0.95or above c) input voltage range: 140V- 280V with cutoff d) THD: =87%, f) ambient temperature : 0° C to 40° C, g) generator compatibility, h) pure sine wave, i) battery over charge & under charge cut off, j) bypass arrangement, k) EN/IEC 620401 for General Safety compatibility l) EN/IEC 620402 for Electromagnetic Compatibility m) EN/IEC 620403 for Performance n) EN/IEC 620404 or equal for Environmental compatibility o) LED+LCD Display p) Approved UPS make : NUMERIC/DELTA or equivalent q) Approved Battery make: 12V,40Ah x 6 nos,C10 or higher rated tubular Exide/Amaron Quanta or equivalent r) Architecture; Tower type( rack mountable not acceptable ) s) Marking: CE, BIS, RoHS t) All certificate copy to be submitted u) Warranty: 3 year after SITC.
31.10.1:Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVCinsulated copper conductor single core cable in surface / recessed medium class PVC conduit,with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLSPVC insulated copper conductor single core cable etc as required.Group A
4OD143018/2026-2027:Supply & installation of light fittings on 'C/U' shaped flat iron bracket Supply, conveyance, installation, testing and commissioning the light fittings of following types made from 0.5mm CRCA sheet complete with all accessories and lamps etc. directly on wall using 2 nos. 'C/U' brackets made from 20 x 3 mm MS flat, painting the flat iron bracket and giving connections with required length of 16/0.20mm 3 core copper conductor flex wire conforming to relevant ISS or extending the original wiring and giving connection etc. as required. LED light fittings made of CRCA sheet with 0.5mm thickness complete with all accessories and lamps etc. 1200 mm 20 W T8 LED tube , having total efficiency of 100 Lumen /watt with 4 feet Aluminium extrusion in the tube for better heat dissipation,, THD < 20% PF> 0.95 ( LM 79 & LM 80 Certificate from NABL should be submitted )
51.25:Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
690.4.2:Supply and installation of suitable size MS belt type fan clamp fabricated from flat iron 40 x 6 mm, 150mm long x 2 Nos with M.S. rod bent to shape, neatly painted with 2 coats of enamel paint over a coat of red oxide primer as per IS 732 as required.
719.1:Supply, installation, testing and commissioning of 1200 mm sweep BEE-5 star rated ceiling fan with brushless direct current motor (BLDC) , class of insulation B , 3 no:s blades , 30 cm long down rod , 2no:s canopies, shackle kit, safety rope , copper winding, power factor not less than .9, service value (CM/M/W) minimum 6.00, Air delivery minimum 210 cum/min,350 RPM (tolerance as per IS :374-2019, THD less than 10% remote or electronic regulator unit for speed control and all remaining accesories including safety pin, nut and bolts , washers, temperature rise equal to 75 deg celsius ( maximum) , insulation resistance more than 2 Megaohm , suitable for 230V,50 Hz, single phase AC supply , earthing etc., complete as required:
8OD143296/2026-2027:Supply and providing every additional length of down rod of 15mm heavy gauge GI / WI pipe with 16/0.20mm PVC insulated and PVC sheathed 3 core round copper conductor flex wire conforming in relevant ISS or with original wiring extended including painting as required
91.31:Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required. (For light plugs to be used in non residential buildings).
101.56:Supplying and fixing suitable size Gl box with modular plate and cover in front on surface or in recess, including providng and fixing 2 Nos. 3 pin 5/6 A modular socket outlets and 2 Nos. 5/6 A modular switches, connection etc. as required. (For light plugs to be used in non residential buildings).
111.32:Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required.
121.21.1:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm
131.21.2:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.25 mm
141.17.3:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 X 1.5 sq.mm
151.17.6:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.6 x 1.5 sq. mm
161.17.12:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 2.5 sq. mm
171.17.21:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 4 sq. mm
18OD143164/2026-2027:Supplying and fixing DP sheet steel enclosure on surface/ recess along with 40 amps 240 volts DP Isolator complete with connections, testing and commissioning etc. as required.
19OD138955/2026-2027:Supplying and clamping the following sizes of corrugated pvc flexible conduit withnecessary compression gland with locking ring and check nut at terminationpointed using suitable size GI/painted MS saddles spacing not exceeding 60 cmson surface including making good the damages.25 mm dia .
202.3.3:Supplying and fixing following way, single pole and neutral, sheet steel, MCBdistribution board, 240 volts, on surface/ recess, complete with tinned copperbus bar, neutral bus bar, earth bar, din bar, interconnections, powder paintedincluding earthing etc. as required. (But without MCB/RCCB/Isolator)12 way, Double door
2190.11.1.14:Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required4 way (8+12) - double cover TPN vertical DB with provision for fixing 4P MCB / Isolator/ RCCB/ RCBO as incomer and SP/ TP MCB as outgoing (IP 42/43)
222.12.1:Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
232.10.4:Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, \\"\\"C\\"\\" curve, miniaturecircuit breaker suitable for inductive load of following poles in the existing MCBDB complete with connections, testing and commissioning etc. as required.Triple pole
242.13.1:Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
252.11:Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required.
262.14.1:Supplying and fixing following rating, double pole, (single phase and neutral),240 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 milli amperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.25 amps
272.15.2:Supplying and fixing following rating, four pole, (three phase and neutral), 415volts, residual current circuit breaker (RCCB), having a sensitivity current 30milli Amperes in the existing MCB DB complete with connections, testing andcommissioning etc. as required.40 amps
282.10.1:Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, \\"\\"C\\"\\" curve, miniaturecircuit breaker suitable for inductive load of following poles in the existing MCBDB complete with connections, testing and commissioning etc. as required.Single pole
29OD138956/2026-2027:Dismantle old ceiling rose points, tube lights, batten, fan, panel board, angle iron frame work, cables, pipe etc. from site and convey the same into departmental store.
305.4:Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
315.11:Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required.
325.15:Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 58036793
AUTHORITY Government Departments
TENDER VALUE 2.70 Lakhs
LAST DATE 23-10-2026
Authority
Authority Name Irrigation Department
Work Description Tender for General-Keri- Hydraulics Division-Electrification Works Of Hydraulics Division Office-General Electrical Work
Basic Detail
Tender No C-ETN-OCT/EL/2026-27
Bidding Type Tender
Location
City Thrissur
State Kerala
Key Dates
Publish Date 14 Oct 2026
Submission Date 23 Oct 2026
Open Date 26 Oct 2026
Finance
Tender Value 2.70 Lakhs
Tender Fee 600
EMD 6770
Exemption Not Available
Document List
7a11b1fe-ee20-4cc6-8346-6b6e58871171.html
BOQ_1494975.xls
KERIHydraulicsDivision100_1.pdf
Tendernotice_1.pdf
Tendernotice_2.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Oct 14, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Oct 23, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 5 days
Oct 26, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 8 days

Tender Documents

Download All (ZIP) ↓
html

7a11b1fe-ee20-4cc6-8346-6b6e58871171.html

xls

BOQ_1494975.xls

pdf

KERIHydraulicsDivision100_1.pdf

pdf

Tendernotice_1.pdf

pdf

Tendernotice_2.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender