Housing Urban and Rular Development Government Departments Closing in 17 days TDR #58036716

Tender For B.O.Q For Renovation/ Repairment Of Administrative Block At Sdh Tangmarg B.W.O Electric Work

Issued by Government Departments · Baramulla, Jammu and Kashmir
Tender Value
4.13 Lakhs
Estimated cost
Bid Submission
02 Nov 2026
17 days left
EMD
8260
Bank guarantee accepted
Document Fee
200
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Baramulla → Jammu and Kashmir
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for B.O.Q For Renovation/ Repairment Of Administrative Block At Sdh Tangmarg B.W.O Electric Work

BOQ

Name of Work:- B.O.Q for Renovation/ Repairment of Administrative Block at SDH Tangmarg B.W.O Electric work
Sl. No. Item Description
1Internal Electrification Meeting Hall Part A
2Wiring for Light point/Fan point/Exhaust fan/Bell point with (P+N+E) 3x1.5 sq.mm FRLS-H PVC insulated Multi strand Copper conductor single core cable, (Havells Lifeguard/Anchor fireguard/Polycab Green/Apar Shakti/Eq Make) in surface/recessed Conduits laid in slabs (Excluding Cost of Conduit/channel 25mm) with 01 No.of 6 Amp Modular Switch,Modular Plate,Cover in front & suitable GI box etc ISO/IEC Certified/Schneider Zencelo/ Havells Crab tree/ Legrand Arteor/Anchor roma plus/ABB Tvisha/SSK Envy/Eq.Make &Including cost 3x2.5 Sq.mm (P+N+E) circuit wire. The items shall be approved before execution of work by SDO.
3Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required,ISO/IEC Certified of Havells/ Legrand/Anchor/Schneider /ABB/Eq Make & shall be approved before execution of work by SDO.
4Wiring for Power Plug with (P+N+E) 3 x 4 sq.mm FRLS-H PVC Insulated Multi strand Copper Conductor single core cable in surface/Recessed Conduit (Havells Lifeguard/Anchor fireguard/Polycab Green/Apar Shakti/Eq Make) Excluding cost of conduit/channel
5Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required, ISO/IEC Certified of Schneider Zencelo/ Havells Crab tree/ Legrand Arteor/Anchor roma plus/ABB Tvisha/SSK Envy/Eq.Make & shall be approved before execution of work by SDO.
6Wiring for 6Amp Plug(Computer Point) with (P+N+E) 3 x 2.5 sq.mm FRLS-H PVC Insulated Multi strand Copper Conductor single core cable in surface/Recessed Conduit (Havells Lifeguard/Anchor fireguard/Polycab Green/Apar Shakti/Eq Make) Excluding cost of conduit/channel
7Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including proving and fixing 2 nos. 3 pin 5/6 A modular socket outlet and 2 nos. 5/6 A modular switch, connections etc. as required. (For light plugs to be used in non residential buildings), ISO/IEC Certified ofSchneider Zencelo/ Havells Crab tree/ Legrand Arteor/Anchor roma plus/ABB Tvisha/SSK Envy/Eq.Make & shall be approved before execution of work.
8Wiring for Sub main Wiring along with earth Wire with the following Sizes of FRLS-H PVC insulated copper conductor, single core Cable in surface/Recessed medium class PVC conduit (Havells Lifeguard/Anchor fireguard/Polycab Green/Apar shakti/Eq Make) & shall be approved before execution of work (Excluding Cost of Conduit/Channel)
92 X 10 sq. mm + 1 X 6 sq. mm earth wire
102 X 6 sq. mm + 1 X 6 sq. mm earth wire
11Supply/Fixing/Testing and Commissioning of 6Amp to 32Amp Rating SP,240v,*C* Curve 10K, Miniature Circuit Breaker suitable for inductive load of following poles in existing MCB . DB Complete with connections.(L&T/Siemens/Legrand/Havells/ABB/Eq. Make)
12Supply/Fixing/Testing and Commissioning of following rating, Double pole, (P+N) 240 V, C* Curve 10K,Miniature Circuit Breaker (MCB) in the existing MCB DB complete with connections. (L&T/Siemens /Legrand/Havells/ABB/Eq Make)
1363 Amp.
1440 Amp.
15Supplying and Fixing of MCB way 6-way (4 + 18), horizontal typed , sheet steel, Double Door Distribution Board, TPN 240V/415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc, as required. (L&T/Siemens/Legrand/ Schneider/ABB/Eq Make)
16Supply/Installation/Testing and Commissioning of 15W + LED Conceal/Surface (Commerical Type) light luminary fitting round shape with minimum system lumen efficacy of 100 lm/W with Pressure Die cast Aluminium Heat Sink and P.F.>0.95 ,THD<10% ,CCT 5700K, CRI 80.The LED with Useful life of 50000 Hrs at L70.. The Input voltage range shall be 150V to 270V .The Fixture should have In-built Surge Protection of 2kV.Certification:- LM79 & LM80 test report should be from govt approved In-house NABL lab/government of India authorised lab.The job includes AMC (reckoned from date of successful commissioning) of lighting fixtures for a period of Two years,which includes replacement of fixtures of Philips/Havell's/Wipro/Halonix/Eq Make.
17Supply, Installation, Testing and Commissioning of 1200 mm sweep, ceiling fan with 3 No. Aluminium blades, 30 cm long down rod, 2nos. canopies, shackle kit, Power Factor not less than 0.9, Service Value including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, and including iron hook complete . USHA Striker/Havells Oyster matalic/CromptonAura/equivalent make as directed by engineer incharge.
18Supply/Installation/Testing and Commissioning of 225-250mm Shutter Typed,320 Cu.m/Hr.AC 220-240 Volts, 50 Hz Exhaust fan made out of ABS Plastic Material with inbuilt thermo cut-off Protection and Noise Level not exceeding 37dB of Following Sizes including connection etc USHA/Havells/Crompton/Eq. Make.(Min 1-Star)
19Supply/Laying/Connecting and Commissioning of 50 sq.mm 3.5-Core XLPE/PVC insulated and steel armored 1.1 KV grade Aluminum Cable of Havells/Polycab/Eq. Make with required size of thimbles dully crimped with hydraulic crimping tool including Providing/Fixing of saddles/clips with making of connection and partially to be laid underground through DWC High Density Poly ethylene Pipe having Corrugation on Outer wall and Plain surface inner wall Conforming to IS: 14930 Part-1 and 2 Complete with accessories for Protection of 1.1 KV Grade under Ground cable Directly in Ground at a Depth of 50 CM including excavation and Refilling the Trench .(Material to be approved before execution)
20Supply/Installation/Testing and Commissioning of CPRI Approved (IS/IEC:61439) Main Controlling Panel,fabricated out of heavy gauge sheet steel ,dully Painted with powder coated paint ,dust protected ,earth terminal fitted on epoxy cleats, volt meter & Ammeters with selector switch & CT Coil of required ratio with all necessary connections & inner wiring of panel on both heating and lighting circuits. The switches are connected with bus bars inside panel & manufacturer CPRI Certified.The switch are adjustable type made of Havells/ L&T/ABB/Legrand/Siemens Make and change over switch should be of Havells/ L&T/Legrand/ Schneider Make.(1) Normal Incomer:a) 125 Amp-4-Pole ,25kA C-CURVE MCCB with extended terminals Havells/L&T/Legrand/Schneider Make as approved=01 No. b) 200 Amps TPN Al. Bus Bar Set = 01 Set,Digital Voltmeter ,Ammeter ,C.T Coils with Selector Switch & Phase indicator Set.125 Amp. 4-pole changeover to switch between main supply and generator supply.Outgoing:(1) Normal outgoing for Heating/AC/Lighting/Inverter etc load(a) 63-Amp DP MCB = 02 No. for Heating Sub-main.(b) 40-Amp DP MCB= 02 No. for Lighting/Machine Sub-main
21ENVIRONMENTALLY SAFE MAINTENANCE FREE COPPER Rod EARTHING SYSTEM Necessary soil treatment is to be made by the contractor in order to improve the Pit resistance Value .Supplying, Installation and Testing of 75 mm copper Pipe Filled with Crystallineconductive Mixture with Eco friendly GEM Backfill Compound 2No. Bags also having Earth pit chamber (300mm x 300mm) with man- hole cover for the above. Including cost of 2OMM Wide copper strip as required in one run fitted with of brass nut bolt & spring washer from EARTHING ROD up to MAIN Control PANEL through DWC High Density Poly ethylene Pipe having Corrugation complete job
22Supply and fixing of PVC ceiling rose (2/3 pin), ISI marked, suitable for connection of light/fan point, complete with necessary accessories, including connections and testing as required of Havells/Anchor/Legrand/Eq.make
23Supply and fixing of Hylum sheet (phenolic laminated sheet), 3 mm / 6 mm / 10 mm thick (as specified), duly cut to required size and shape, fixed with necessary nuts, bolts, screws, washers, spacers etc., including finishing and making good the surface, complete as required Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 58036716
AUTHORITY Government Departments
TENDER VALUE 4.13 Lakhs
LAST DATE 02-11-2026
Authority
Authority Name Public Works Department
Work Description Tender for B.O.Q For Renovation/ Repairment Of Administrative Block At Sdh Tangmarg B.W.O Electric Work
Basic Detail
Tender No NIT No.193/2026-27 Dt 14/10/2026
Bidding Type Tender
Location
City Baramulla
State Jammu and Kashmir
Key Dates
Publish Date 14 Oct 2026
Submission Date 02 Nov 2026
Open Date 03 Nov 2026
Finance
Tender Value 4.13 Lakhs
Tender Fee 200
EMD 8260
Exemption Not Available
Document List
13c9c475-e3a4-4e98-b1d8-2f9f28ac2aa8.html
BOQ_1110973.xls
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Oct 14, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Nov 02, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 17 days
Nov 03, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 18 days

Tender Documents

Download All (ZIP) ↓
html

13c9c475-e3a4-4e98-b1d8-2f9f28ac2aa8.html

xls

BOQ_1110973.xls

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender