Tender For Upgradation Of Play Fields Parks At Various Sports Complexes.Sub Head :Sitc Of Vrf/Vrv System In Gym At Siri Fort Sports Complex.
Tender Value
47.90 Lakhs
Estimated cost
Bid Submission
22 Oct 2026
4 days left
EMD
95813
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Delhi → Delhi
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Upgradation Of Play Fields Parks At Various Sports Complexes.Sub Head :Sitc Of Vrf/Vrv System In Gym At Siri Fort Sports Complex.
BOQ
| Sl. No. | Item Description |
| 1 | Supplying, Installation, replacement(i/c rebate of old item), Testing & Commissioning of Modular type Variable Refrigerant Flow/Variable Refrigerant Volume air cooled Outdoor units suitable for cooling/heating having 100% hermetically sealed inverter type twin Rotary/Scroll Compressor(s),minimum two compressors (with individual separate PCB) for above 14HP modules, microprocessor based Controller, top discharge type condensing unit(s), with R-410-A Refrigerant or equivalent, vibration Isolators with suitable foundation etc. complete as required. To have better efficiency condenser fan shall be capable to operate at different speed with respect to load.The unit shall deliver the rated capacity and in confirmation as per IS 18728:2024 and CPWD Specifications and work even at 50°C ambient temperature without tripping. The system shall be able to deliver 100% of the rated capacity upto 39°C. The unit shall be suitable to work on 400V +/- 10%, 3 Phase, 50Hz AC power supply and BMS compatible. The unit shall be filled with first charge of the refrigerant and ready for use as required. The condenser should be coated with a hydrophilic film to prevent water accumulation on the surface of the heat exchanger, enhance water dispersion and reduce the risk of degradation, thereby improving overall performance and durability. The Indian Seasonal Energy Efficiency Ratio (ISEER) of the unit shall be as per Energy Conservation and Sustainable Building Code (ECSBC) 2024 as below and complete as per CPWD specification, connections, inter connections etc. as required. (For capacity <40 kWr ISEER 7.4, Capacity > 40 and <70 ISEER 7.5, Capacity > 70 ISEER 7.6 for Super ECSBC Building). - (DSR Item: 31.3.3)Outdoor unit: 22 X 4 = 88 HP Outdoor unit: 12 X 1 = 12 HP |
| 2 | Supply, Installation,replacement(i/c rebate of old item), testing and commissioning of following minimum capacity and external high static pressure VRF/VRV ceiling mounted ductable type Indoor unit equipped with washable synthetic media pre-filter, fan section with low noise fan/dynamically balanced blower, multispeed motor, coil section with DX copper coil, electronic expansion valve, corded remote control, outer cabinet, vibration isolators, drain pan, other necessary supports etc., suitable for operation on single phase AC supply 230V±10%, 50Hz complete as required. The unit shall have automatic force shut down provision in case of fire on receiveing signal from BMS System. The cooling capacity of indoor unit will be at air inlet conditions of 27 Degree C DB and 19 Degree C WB temperature. Ductable Type : - 8 TR - (DSR Item: 31.12.4) |
| 3 | Supply and Installation of Remote controllers (Corded) for operation of indoor units (MR) |
| 4 | Supply, installation, testing & commissioning of Ceiling Suspended Treated Fresh Air Unit. (MR)1300 CFM (For Gym Area) |
| 5 | Supply, installation, testing & commissioning of AHU Kit for TFA for 1300 CFM Ceiling Suspended Unit. (MR) |
| 6 | Supply, Installation, Testing and Commissioning of variable refrigerant flow distribution couplings with insulation for refrigerant piping 'Y' Joints in copper piping. (DSR Item: 31.13.1) |
| 7 | Refrigerant PipingSupply, Installation, replacement(i/c rebate of old item), Testing and Commissioning including vaccumiazation and Nitrogen testing of following nominal sizes of soft/hard drawn copper refrigerant piping for VRF/VRV system, complete with fittings, with suitable adjustable ring type hanger supports, jointng/brazing including accessories insulated with XLPE Class O tubular insulation/with Class O closed cell elastometric nitrile rubber tubular sleeves sections of specified thickness as given below for Suction and Liquid lines, all accessories as per specification etc as required: (DSR-2025-31.14)12.7 mm dia (OD) (soft drawn) with tube thickness 1.2 mm with 19mm thick insulation |
| 8 | 15.86 mm dia (OD) (soft drawn) with tube thickness 1.2 mm with 19mm thick insulation |
| 9 | 19 mm dia (OD) (Hard drawn) with tube thickness 1.2 mm with 19mm thick insulation |
| 10 | 22.2 mm dia (OD) (Hard drawn) with tube thickness 1.2 mm with 19mm thick insulation |
| 11 | 28.58 mm dia (OD) (Hard drawn) with tube thickness 1.2 mm with 19mm thick insulation |
| 12 | Drain pipingSupply, installation testing & commissioning of rigid UPVC piping complete with fittings, supports as per specifications and duly insulated with 6/9 mm thick closed cell nitrile rubber insulation. (MR) 25 mm dia ( with 6 mm nitrile rubber Insulation) |
| 13 | 32 mm dia ( with 9 mm nitrile rubber Insulation) |
| 14 | DuctingSupply Installation Testing and Commissioning of factory fabricated GSS sheet metal ellipctical ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required( as approved by Enginner-in-charge). - 0.80 mm- (DSR Item: 30.12.2.2) |
| 15 | Supply and fixing of following thickness duly laminated aluminum foil finish closed cell Nitrile rubber (Class 'O') insulation on existing duct after applying suitable adhesive for Nitrile rubber. The joints shall be sealed with 50 mm wide and 3mm thick self-adhesive nitrile rubber insulation complete as per specifications etc as required. - 19 mm - (DSR Item: 30.23.1) |
| 16 | Supply,installation,testing and commissioning of fire retardant nonporous double layer flexible canvass connection between each indoor unit and ducting. (MR) |
| 17 | Supply and Fixing installation, testing and commissioning of supply air diffusers of powder coated aluminium with aluminium volume control dampers with anti smudge ring & removable core in confirmation to SMACNA/IS and as per specifications complete etc. as required. (DSR Item: 30.17) |
| 18 | Supply and Fixing installation, testing and commissioning of Return air diffusers of powder coated aluminium without volume control dampers with anti smudge ring & removable core in confirmation to SMACNA/IS and as per specifications complete etc. as required (DSR Item: 30.18) |
| 19 | Cable TraySupplying and installing following size of perforated painted with powder coating M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with two numbers MS/GI Suspenders i/c base of suitable size MS/GI angle, bolts & nuts, painting suspenders, fastner etc as required. (DSR-2025- 4.1.2) - 150 mm width X 50 mm depth X 1.6 mm thickness |
| 20 | Supply & installation of control cum transmission wiring of 2 core x 1.5 sq mm copper in suitable existing pvc conduits between indoor and out door unit. (MR) |
| 21 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. (DSR-1.21.2)) - 25 mm Size |
| 22 | Supply of Power cable of following sizes XLPE insulated Copper armoured conductor cable to VRF outdoor unit from main electrical panal. The cost shall include all necessary supports clamps etc as necessary as required. - 4C x 16 sq mm |
| 23 | Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required. (DSR)a) Upto 35 sq. mm |
| 24 | Supplying, making end termination with brass compression gland and aluminium lugs for following sizes of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. - 4C x 25 sq mm |
| 25 | SITC of outdoor type Feeder pillar, cubical type fully compartmentalized made out of 2 mm thick CRCA Sheet having IP54 protection with canopy, pedestal mounted, suitable for use on 415V, 3 Phase, 4 wire, 50 HZ and complete with powder coated painting through seven-tank process facility for pricking and degreasing, of suitable size for accommodating the following component, including providing detachable gland plate of 3 mm thick for incoming and outgoing cables entry, erected on cement concrete foundation made, complete with painting, interconnections, earthing, provision for protection from rain dust, fixed on MS angle iron frame work of size 50 mm x50 mm x 6 mm (NS) 100 cm long legs out of which 50 cm duly grouted in cement concrete 1:2:4 (1 cement: 2 sand: 4 stone) aggregate etc complete as required.a) Incomer1. 200A TPN MCCB, 35KA with Thermal magmatic release for O/L+S/C protection - 1 No.ii) Digital Ammeter ,CL:1.0 - 1 No. iii) 200/5 amps CT CL:1.0 - 3 Nos.iv) CT's shorting links- 4 Nos. v) Digital Voltmeter CL:1.0 - 1 No.vi) R - Y , LED Type Indicating lamp - 2 No. vii) B, LED Type Indicating lamp -1 No.viii) 32 A neutral Link-1 No. ix) 2A SP MCB-6 Nos.x) ASS- 1 No. xi) VSS- 1No.b) Busbari) 300 Amps TP&N Aluminium bus bars mounted on SMC supports.c) Outgoing- TPN MCCB 63 Amps 16 KA- 6 Nos. SP MCB 15/16 A- 2 Nos.DP MCB 32 A -1 No. |
| 26 | Supply,installation, testing and commissioning of MS epoxy painted stand for installation of outdoor units. |
| 27 | Providing and Fixing of crossed linked polyethylene insulation 13 mm thick fire retardand, self extingushing type, density not less than 24 Kg/m3, 'K' value not more than 0.028 Kcal/degC for underdeck insulation. |
| 28 | Weather proof box with 63 Amp. 4 Pole TPN of suitable ratings near the outdoor units for isolations. |
| 29 | Providing of anti corrosive layer coating on ODU unit complete for weather protection on exposed copper pipe as per OEM specifications. |
| 30 | Earthing with G.I. earth pipe 4.5 Meter long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required. (DSR-2025-5.2) |
| 31 | Providing and fixing 6 SWG dia GI wire on surface or in recess for loop earthing as required. (DSR Item: 5.16) |
| 32 | Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required. (DSR-2025- 5.15) Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Oct 14, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedOct 22, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 4 daysOct 23, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 5 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender