Tender For Construction Of 1.00 Ml Capacity Reinforced Cement Concrete Esr With Piping And Ancillary Works For Improvement Of 24X7 Water Supply To Niladrivihar Budhhavihar, Ga Lumbinivihar, Defense Colony & All Other Adjoining Areas In Niladrivihar B
Tender Overview
Project Description
Tender for Construction Of 1.00 Ml Capacity Reinforced Cement Concrete Esr With Piping And Ancillary Works For Improvement Of 24X7 Water Supply To Niladrivihar Budhhavihar, Ga Lumbinivihar, Defense Colony & All Other Adjoining Areas In Niladrivihar Bhubaneswar.
Corrigendum
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 27-Oct-2026 | Corrigendum | Date | 05-Nov-2026 |
BOQ
| Sl. No. | Item Description |
| 1 | CONSTRUCTION OF ESR OF 10.00 LAKH LTRS CAPACITY WITH A STAGING HEIGHT OF 30 MTR |
| 2 | Design, Construction, Testing & commissioning of 1no RCC ESR of capacity 10.00 lakh Litre at Foot Hill Pump house including all works such as soil investigation , excavation,required footing of raft/pile, back filling & disposal of earth, RCC & PCC of required grade, shuttering, brickwork, painting, finishing, connection pipes upto 10m beyond tank structure,valves fitting, expansion joint, expansion bellow, Ultrasonic level Transmitter ,lighting arrester etc. including supply of all labours, materials, tools & plants including testing & commissioning etc all complete as per specification and direction of Engineer-in-charge.. (upto 30 mtr. Ht.) |
| 3 | Foot Hill Pump House |
| 4 | CONSTRUCTION OF POSITIVE SUCTION PUMP HOUSE OF INTERNAL DIMENSION ( 8.00 MTX 5.00 MTR) |
| 5 | Earth work of excavation in Cutting in disintegrated rock not requiring blasting to be removed by pick axes and crow bars and depositing materials within 50m initial lead and 1.5m initial lift including rough dressing as per direction and specification of the department including stacking the useful materials separately as ordered etc as per direction of Engineer - in - Charge. |
| 6 | 1st depth |
| 7 | Earth work of excavation in founation in laterite rock or any hard rock (other than granite or disintigrated rock) removed by chiselling including dressing and levelling the bed not exceeding 1.5m in depth and depositing the soil within initial lead of 50m and as per specification approved by the Department |
| 8 | 1st depth |
| 9 | 2nd depth |
| 10 | Supplying all materials, labour, T&P and filling in foundation and plinth with sand well watered and rammed including conveyance of all materials to work site, payment of royalty , taxes& labour cess etc all complete as per specification and direction of Engineer-in-charge. |
| 11 | Cement concrete (1:3:6) with 4cm. Size crusher broken hard Granite metal including cost of all labour ,materials with all taxes, lead ,T & P etc all complete . |
| 12 | Supplying all labour , T&P and removing surplus earth /debrise by mechanical means within 5 K.M radious etc all complete as per the direction of EIC. |
| 13 | Fly ash bricks of 25cmx12cmx8cm. Size having crushing strength not less than 75 Kg/Sqcm. With dimensional tolerance +2%. percentin cement mortar (1:6) brick masonary in super structure |
| 14 | In foundation and plinth |
| 15 | In superstructure |
| 16 | R.C.C work in ground floor of M-25 grade with 20mm & down grade crusher broken hard Granite chips including hoisting & laying with cost of all labour, materials with all taxes, lead ,T & P etc all complete . |
| 17 | Rigid smooth centring and shuttering for R.C.C. works including false work and dismantling then after casting including cost of materials all complete. |
| 18 | R.C.C. Foundation, Plinth Band, Footings, Bases of Columns, Mass Concrete & Precast Slabs etc. |
| 19 | R.C.C. Walls and Fins |
| 20 | RCC columns & beams |
| 21 | RCC walkway slabs |
| 22 | RCC beams |
| 23 | RCC lintel |
| 24 | RCC chajja |
| 25 | Supplying, fitting and placing uncoated HYSD bar reinforcement complete as per drawing and technical specification. |
| 26 | 6 mm thick cement plaster (1:4) to RCC surfaces finished smooth including closed deep chiping and slury treatment ( for inside area) |
| 27 | Supplying, fitting and fixing of Stainless steel of 304 grade in hand railing using 50mm dia of 2mm thick circular pipe with Balustrade of size 32mm x 32mm x 2mm @ 0.90mtr. C/C and stainless square pipe bracing of size 32 mm x 32 mm x 2 mm in 3 rows in stair case as per approved design and specification, buffing, polishing etc with cost, conveyance, taxes of all materials, labour, T&P etc. required for the complete in all respect.C/C and stainless square pipe bracing of size case as per approved design and specification, buffing, polishing etc with cost, conveyance, taxes of all materials, labour, T&P etc. required for the complete in all respect. |
| 28 | Supplying all materials, labour, T&P and fixing of Fixing KOTA Tile in floors or steps & landing on 25mm. thick bed of cement mortar (1:1) jointed with neat cement slurry mixed with pigment to match the shades of the tiles including rubbing & polishing complete polishing etc all complete. as per the direction of the Engineer in charge. |
| 29 | Supplying all materials,labour and T&P for fitting and fixing of single Monorail section made out of ISMB 250X 125mm ( I section joist) including hoisting of the ISMB and placing in position under roof ceiling rigidly supported on the walls and beams at both ends and mid points with fixing of 16mm thick MS plate dully welded and jointed with the top flange of the ISMB and anchored on walls and beams with rigid and adequate bolting as per site condition including fitting and fixing of mechanical pulley 3 MT capacity with chain all complete confirming to IS-800-2007 for the positive suction pump houses etc all complete as per the direction of Engineer in charge. |
| 30 | ISMB ( 250x 125mm ) |
| 31 | MS plate ( 300mmx 300mmx 12mm ) |
| 32 | Supplying all materials, labour and T&P for Flame cutting and facing of MS plate or pipes from 8mm to 12mm thick including supply of all labor, material, tools & plants for following plate thickness all complete as per specification and direction of Engineer-in-Charge. |
| 33 | Welding with two welding beads/pass, conforming to IS:816-1998 (Fillet weld) to MS pipes and fittings at site |
| 34 | Hoisting joists and trusses and placing in position |
| 35 | Drilling holes 12mm to 25mm dia in iron flats, angles, tees etc. above 10mm thick & upto 16mm thick with hand drill(labour only) |
| 36 | Supplying all labour ,materials and t& P for fitting and fixing of indef ( P3) 3 Ton with 5 mtr Chain pulley block with double bearing , grade-80 material with rugged german design , zinc plated , casting type- Fully pocketed , spheroidal graphaite cast with 0.50 MT over load capacity with powder coated finished, the pulley block shall be comprised of , frame, gears, pawl, bearings, hooks, , load chain, load chain wheel, hand chain, hand chain wheel, hand chain guide and all other components like guide, stripper, midler wheels, anchorage etc confirming to IS 3832-1986 all complete as per direction of Engineer in charge |
| 37 | Supplying all labour, materials and toold and plants for enamel painting two coats over a coat of primer on MS doors/grills, ISMB joist, MS plate etc as per the approved shade and colour as per direction of Engineer in charge |
| 38 | 16 mm. thick cement plaster (1 :6) over brick or stone masonry |
| 39 | 12 mm. thick cement plaster (1 :6) over brick or stone masonry |
| 40 | 20mm. thick cement plaster (1:6) for stone work |
| 41 | Provision for Plastic emulsion painting two coats to walls with over a coat of primer of approved shade on plastered surface to give an even shade in all heights including cost, conveyance, taxes of all materials, cost of all labour, T&P safety belts, sundries etc. as required for the work complete . |
| 42 | Supplying all materials labour T&P for providing M.S. Grill/ Grill gate /Pipe as per following size as per specification.all complete. |
| 43 | Providing , fitting & fixing up UPVC ( Unplasticized Poly vinyle Chloride ) window (sliding type) with 5 mm clear float glass of LG profile as per approved specification including all cost conveyance labour T & P etc complete as per direction of Engineer in Charge. |
| 44 | Cement concrete (1:4:8) with 4cm. Size crusher broken hard Granite metal including cost of all labour ,materials with all taxes, lead ,T & P etc all complete . |
| 45 | Cement concrete (1:2:4) with 12cm. Size crusher broken hard Granite chips including cost of all labour ,materials with all taxes, lead ,T & P etc all complete . |
| 46 | Recessed / Surface wiring to light point / fan point /Exhaust fan point /call bell point with 1.5 sqmm FR PVC insulated single core multi strand copper conductor of ISI marked with 20 mm dia non-m , MS box with 1.5 sqmm FR PVC insulated single core multistrand copper conductor as earth wire including all accessories and connection (Make of wire:-Finolex/Lauritz Knudsen /Anchor/ Havells /V Guard/Equivalent make with approval of the authority) |
| 47 | Light Points, Group - A |
| 48 | Light Points Group - B |
| 49 | 5A Plug Point |
| 50 | Fan Point (Group - A) |
| 51 | Supplying all materials labour & T & P for fitting & fixing of following electrical installations including testing & commissioning etc. complete as per direction of Engineer in Charge. |
| 52 | Step up modular regulator for Fan |
| 53 | 15watt LED Bulb. |
| 54 | 1200mm Ceiling Fan (Make-Havells/ Bajaj/Usha/ Equivalent make with approval of the authority) |
| 55 | Electric 200mm Exhaust Fan (Make-Havells/ Bajaj/Usha/ Equivalent make with approval of the authority) |
| 56 | Titanio Pro LED Tube Light -18W (Double side connection)(Make-Havells/Phillips/ Equivalent make with approval of the authority) |
| 57 | 32A Double Pole MCB. |
| 58 | 5 Amp switch |
| 59 | 5 Amp socket |
| 60 | Ceiling Rose - |
| 61 | Angle Holder |
| 62 | 2.50 Sqmm 3 core copper armoured Cable (Make:-Finolex/Lauritz Knudsen /Anchor/ Havells /V Guard/Equivalent make with approval of the authority) |
| 63 | Providing weather coat painting two coats over a coat of primer of approved shade of walls including cost conveyance of all materials, etc. all complete as per specification & direction of Engineer-in-charge. |
| 64 | Supplying all materials labour T&P for providing fitting & fixing of MS plate 6mm thick over the door grills as per following size as per specification.all complete. |
| 65 | Supplying all labour, materials and toold and plants for enamel painting two cioatrs over a coat of primer on MS doors/grills as per the approved shade and colour as per direction of Engineer in charge |
| 66 | Double Stage Centering and Shuttering for Roof Slabs, Balconies and Projections above 3.60m and upto 7.20m heights |
| 67 | Supplying all labour and tools and plants for Dismantling of RCC walls by means of core cutting of 150mm dia to avoid further damage to adjacent concrete and reinfcorement so that the reinforcement can be rewelded properly by chiselling with electric breaker weighing up to 7.50Kg with capacity of 20 joules impact to concrete at least leaving a weldable length that core should be taken to size they cut slabs to size so that can easily be removed from site by head load or by chain hauled from inside all complete |
| 68 | Supplying all materials labour & T & P for making water proof Micro Concrete of any reputed brand (Preferable Perma Polycrete/jaipax) for R.C.C. works including hoisting and laying etc. complete as per direction of Engineer in charge. |
| 69 | Supplying all labour, materials. T&P for for sealing the Joint usingPerma Polyseal (POLYSULPHIDE SEALANT) in 50mm x 25mm size groove including all cost. conveyance. wastages & taxes etc. all complete. |
| 70 | PROCUREMENT, FITTING & FIXING OF SPLITCASE PUMPSET , VFD PANEL , ELECTRICAL CABLES, PLC PANEL & ANCILARY WORKS |
| 71 | Supplying all labour, materials and tools and plants for installation , testing and commissioning of Horizontal Split case centrifugal pump set Crompton/KBL/WIPL/ Wilo (M&P)/Grundfos/Equivalent make with approval of the authority with Pump rated discharge 96 LPS , Pump rated Head- 55 mtr with Mechanical Seal with Pump material of construction, Casing- Cast iron, Impeller-SS-CF8, Neck ring-SS-CF8, Shaft SS-410 ,Shsleeves -SS410, stuffing box packing mechanical with Offered motor 22.40 KW/60HP RPM 1500/4 pole , Motor Characteristics 415+- 10%, 50 Hz +_ 5 %, S1 Duty , TEFC-SCR, IP55, IE3 efficiency class insulation class F/B , Ambient temp 50* C confirming to IS/IEC ,with acessories Base frame, coupling, coupling guard, Companion flanges etc all complete as per direction of Engineer in charge2w+2s |
| 72 | sunken pump house ( pump set having head - 55 mtr discharge- 96 LPS) |
| 73 | Supply ,Fitting & Fixing of Double door Enclosure system size 1000mmx 1400mmx 400mm |
| 74 | Supply ,Fitting & Fixing of 45KW /60HP VFD (Make :Make-ABB/Siemens/CG/Schnider/Lauritz Knudsen/Equivalent make with approval of the authority) |
| 75 | Supply ,Fitting & Fixing of 100 Amp 36 KA, 4 pole MCCB |
| 76 | Supply ,Fitting & Fixing of SPREADER LINK |
| 77 | Supply ,Fitting & Fixing of MYB4N 24v DC relay |
| 78 | Supply ,Fitting & Fixing of MYB4N relay base |
| 79 | Supply, fitting & fixing of Auto Manual Selector Switch |
| 80 | Supply, fitting & fixing of Start Push Buttom |
| 81 | Supply, fitting & fixing of Start Push Buttom No Element |
| 82 | Supply, fitting & fixing of Stop Push |
| 83 | Supply, fitting & fixing of Stop Push Buttom No Element |
| 84 | Supply ,Fitting & Fixing of Indicator 22mm Red ( DC) , 24v DC |
| 85 | Supply ,Fitting & Fixing of Indicator 22mm green ( DC) , 24v DC |
| 86 | Supply ,Fitting & Fixing of Indicator 22mm orange ( DC) , 24v DC |
| 87 | Supply ,Fitting & Fixing of Indicator 22mm Red ( DC) , 220v AC |
| 88 | Supply ,Fitting & Fixing of Indicator 22mm Yellow ( DC) , 220v AC |
| 89 | Supply ,Fitting & Fixing of Indicator 22mm Blue ( DC) , 220v AC |
| 90 | Supply, fitting & fixing of 63Amp 4P contactor |
| 91 | Supply, fitting & fixing of Volt meter |
| 92 | Supply, fitting & fixing of Ammeter meter |
| 93 | Supply ,Fitting & Fixing of Double door Incomer Enclosure system size 1200mmx 1400mmx 400mm |
| 94 | Supply, fitting & fixing of RYB indicator of incoming powersupply |
| 95 | Supplying all materials, labour & T & P for fitting fixing of 400amp changeover for operating both in main line and DG Purpose |
| 96 | supplying , fitting & fixing of copper flat bush bar |
| 97 | supplying & laying for 300sqmm x 3.5 core Al armoured cable (Make:-Finolex/Lauritz Knudsen /Anchor/ Havells /V Guard/Equivalent make with approval of the authority) |
| 98 | supplying & laying for 185 sqmm x 3.5 core Al armoured cable (Make:-Finolex/Lauritz Knudsen /Anchor/ Havells /V Guard/Equivalent make with approval of the authority) |
| 99 | supplying & laying for 35 sqmm x 3.5 core Al armoured cable (Make:-Finolex/Lauritz Knudsen /Anchor/ Havells /V Guard/Equivalent make with approval of the authority) |
| 100 | Supplying all materials labour T & P for fitting fixing of 16Amp 4pole MCB having breaking capacity of 50KA of reputed make in order to get tripped having phase unbalance of over current or over voltage |
| 101 | Providing and laying in trenches unplasticised HDPE pipes conforming to IS: 4984/2016 of Class IV (8 kgf/cm²) of the following nominal bore and pipe fittings including testing as per specification complete. (Earth work in trenches to be measured and paid for separately) |
| 102 | 160mm HDPE pipe PE-80 |
| 103 | LAYING AND FIXING OF WATER SUPPLY PIPE LINES , VALVES WITH ANCILARY WORKS ETC |
| 104 | Dismantling of cement concrete pavement by mechanical means using pneumatic tools, breaking to pieces not exceeding 0.02 cum in volume and stock piling at designated locations and disposal of dismantled materials up to a lead of 1000 metres, stacking serviceable and unserviceable materials separately |
| 105 | Earth work in all kinds of soil within 50mtr initial lead and 1.5mtr initial lift including rough dressing and breaking of clods to maximum 5cm to 7cm and laying in layers not exceeding 0.3mtr in depth as per direction of Engineer-in-charge. |
| 106 | Supplying all labour, T&P for cutting in dis-integrated rock, not requiringblastingand to be removed by pick axes and crow bars and depositing the materials within 50M intial lead and 1.5M initial lift including rough dressing as per the direction of Engineer-in-charge and the specification of the department including the stacking of useful materials separately as ordered. |
| 107 | Supplying of materials, labour and T&P for excavation of foundation in laterite rock or any hard rock(other than granite or disintegrated rock)removed by chiselling including dressing and leveling the bed not exceeding 1.5mtr depth and depositing the soil within 50mtr initial lead as per specification approved by the Deptt.as per direction of Engineer-in-charge. |
| 108 | Supplying & Laying in trenches Centrifugally Ductile Iron pressure socket & Spigot pipes, Class -K9/K-7 conforming to I.S. 8329 of the following nominal diameter for push on rubber gasket jointing as per the specification, all complete including transportation charges of pipe from Deptt store to work site as per direction of engineer-in-charge ( Earth work in trenches jointing of pipes specials and fitting to be meausred separately ) |
| 109 | 300mm dia D.I K-7 S/S pipe including cost of pipe |
| 110 | 200mm dia D.I K-7 S/S pipe including cost of pipe |
| 111 | Supplying of all labour, and T&P for providing Push-on-joints conforming to IS:3114 to centrifugally (Spun) Cast Iron Pipes or Ductile Iron pipes using rubber gasket conforming to IS:5382 of Styrene Butadene Rubber (S.B.R) quality, testing of joints,etc. all complete as per specifications and directions of Engineer-in-Charge. |
| 112 | 300mm dia Push - on-Joints |
| 113 | 200mm dia Push - on-Joints |
| 114 | Supplying all materials ,abour, T&P for providing ,laying,fixing and testing of DI/CI specials,bends,etc in trenches confirming to IS:1538 all complete (excluding earth work) as per specification and as per the direction of EIC. |
| 115 | Supplying all labour T&P for Cutting of C.I/ D I pipe by eletric arc welding at site including cost of materials,labour,T & P etc all complete e as per the direction of Engineer-in-charge. |
| 116 | Supplying of materials, labour and T&P for laying in trenches C.I. specials conforming to I.S.-1538 of the following diameter as per P.H. specifications . (excluding earth work in excavation,jointing and cost of specials) as per direction of Engineer-in-charge. |
| 117 | 300mm MJ Socketed Tail Piece |
| 118 | 200mm MJ Socketed Tail Piece |
| 119 | Supplying all labour and T&P for providing and laying MS pipe and specials confirming to IS 3589/99 of quality grade FE 410 of following nominal dia and including transportation of pipes and fitting to site etc all complete as per the direction of E.I.C. |
| 120 | 300mm MS Pipe(7.10mm thick) |
| 121 | 300mm dia MS Flange ( 12mm thick) |
| 122 | 300mm x 200mm M.S Reducer plain |
| 123 | 300mm dia M.S. Blank Flange.(16mm thick) |
| 124 | 300mm dia x 90 degree MS bend |
| 125 | 150mm MS Pipe(6.30mm thick) |
| 126 | 150mm MS flange (12mm thick) |
| 127 | 150-100mm MS Reducer Plain |
| 128 | 100mm MS flange (12mm thick) |
| 129 | 200-150mm MS Reducer Plain |
| 130 | 150mm dia x 90 degree MS bend |
| 131 | 200mm dia M.S.Pipe (6.30mm thick) |
| 132 | 200mm dia M.S. Flange.(12mm thick) |
| 133 | Supplying all materials,labour and T&P and making flanged joints for C.I. / D I pipes and specials of the following diameter including testing of joints as per specification and direction of Engineer-in-charge |
| 134 | 200mm flange joints |
| 135 | 300mm flange joints |
| 136 | 150mm flange joints |
| 137 | 100mm flange joints |
| 138 | Supplying all labour and T&P for cutting of following dia MS pipe of following thick in treanches by gas cutter set of pocket etc all complete |
| 139 | Supplying all labour and T&P for jointing following dia MS pipe up to 8.0mm thick in treanches by electric arc welding & genetator set of pocket etc all complete ( at work site) |
| 140 | Supplying all materials Labour & T & P for Fixing Ductile Iron Resilient seated Sluice Valve / NR Valve/ BF Valve with double flanged ends for water works purposes conforming to IS specification for the following nominal diameters as per specification complete including cost of Sluice valve .(Make- VAG/Talis/AVK/IVC/Kirloskar/ Equivalent make with approval of the authority) |
| 141 | 200mm dia D/F Sluice Valve (PN1.6) |
| 142 | 25mm dia Tamper proof Duojet Air Valve |
| 143 | 300mm dia DI D/F Sluice Valve (PN1.6) |
| 144 | 150mm dia DI D/F Sluice Valve (PN1.6) |
| 145 | 150mm dia DI D/F NR Valve (PN1.6) |
| 146 | Supplying and Filling well graded sand including watering, ramming, consolidating, dressing, etc. all complete as per specifications and direction of Engineer In-charge for: (including cost of sand). |
| 147 | Supplying all labour T&P materials for fitting & Fxing of pressure meter Non comtact dipharma type with snubber, pipeing & needle valve at ESR as well as diferent lane & sub-lane to know the water pressure including the cost of pressre meter with drilling holes in pipe line & making good to the damages at including cost all labours T&P etc all complete as per the direction of Engieer-in-charges. 0 to 6kg/sqm pressure meter. -150mm dia |
| 148 | 150mm for deliveryline |
| 149 | Supplying all materials,labour and T&P and constructing brick masonry sluice Valve chamber of over all of following internal ; earth work in excavation in all kinds of soil laying of 150mm thick cc (1:3:6) with crusher broken hard granite metal up to 4cm size metal 250mm thick brick masonary working CM (1:4) with fly ash bricks having crushing stremgth between 75 kg/cmsq 12mm thick cement plastering with CM (1:3) with punning for inside surface & out side plastering above GL & cement pointing below GL etc. all Complete including precast factory made heavy deauty RCC cover slab with frame (SD-20) made out of M30 concrete to with stand again 20mt vehicular load as per the approved drawing if any and the direction of EIC. |
| 150 | S.V. chamber internal size:-[1.00x1.00x1.50mtr] |
| 151 | S.V. chamber internal size:-[0.90x0.90x1.20mtr] |
| 152 | Supplying and Filling well graded sand including watering, ramming, consolidating, dressing, etc. all complete as per specifications and direction of Engineer In-charge for: (including cost of sand). |
| 153 | Cement concrete (1:4:8) with 4cm. Size crusher broken hard Granite metal including cost of all labour, materials with all taxes, lead,T & P etc all complete . |
| 154 | Supplying all materials, labour and T & P for Cement concrete (1:2:4) with 12mm size crusher broken hard granite metal including cost of all labour, materials with all taxes, lead, T & P etc all complete and as per direction of Engineer -in- Charge. |
| 155 | Supply all labour,T&P for carriage of surplus earth by mechanical means with a lead of 10Km including Loading and un loading &conractor profit & Labour cess etc all complete as per the direction of Engineer-in-charge |
| 156 | Supplying all material, labour, T & P for fitting & fixing of double chamber DI Control Valve(globe type) with Solenoid, hydrullic operated wutg stem and positioner for feed back switch, selonoid valve, integral office plate assembly, diffrential control, reverse flow control, restriction orifice body PN-1.6 can be integrated with PLC pannel for opration with a minimum pressure in, upstream 0.2 kg/cm2 to a maximum pressure of 8kg/cm2 of the Approve make(VAG/Talis/AVK/IVC/Kirloskar/Equivalent make with approval of the authority) to control water supply including cost of material with all taxes transportation to site / Storage with insurance. |
| 157 | 300mm flow control valve |
| 158 | 150mm dia flow control valve |
| 159 | Supplying of electric powered electromagnetic full bore type IP 68 fully welded flanged type water flow meter of pulse DC type of flow tube SS304, coil housing & electrodes SS316, SS ring type grounding etc IP68 signal converter remote mounting, input power 24V DC 4-20mA programable LCD display to show Actual flow rate, totalised flow , flow direction, flow velocity, conductivity with + or - 0.5% accuracy etc & provision to diagnositics empty pipe detection, coil temperature, coil resistance etc & compatable to data communication modules with masibus & communication the data to remote SCADA station for live monitoring where ever required including providing data cable & power cable required as per site condition. The standard calibration certificate & guarantee certificate for flow meter & electromagnetic signal converter to be given for minimum one year from the date of installation. The Approve Make(KROHNE MARSHALL/E&H/ABB/SIEMENS/Equivalent make with approval of authority) including cost of material with all taxes transportation of site & storage with insurance. |
| 160 | 300mm flow meter |
| 161 | 150mm flow meter |
| 162 | Supply, installation of chemical earthing with crystalline conducting material for Back Fill Compound & installation of Maintenance Free Earthing Electrode with ISI mark G.I. Pipe dia 50mm as Secondary electrode with wall thickness of 2.6mm and the primary earthing electrode will be 25mm x 6mm hot dipped galvanized strip filled with a highly conductive & non-corrosive compound in between the primary earthing & the secondary earthing. A solid G.I. Base plate of 300 x 300 mm seals the unit at the bottom. Ground filling compound will be provided in 25kg per bag - 2nos. Excavation of earth pit refilling, Precast RCC chamber with lid etc. all complete as per the site requirement. |
| 163 | Supply of Pressure transmeter (transducer) to be installed in delivery main with following technical specification i,e. Range up to 7 kgf/cm2,Type-Sensor, Power Supply-24 DC, Out put-4 to 20mA, (Make-E & H/ABB/VEGA/WIKA/Equivalent make with approval of authority) |
| 164 | Supplying installation & commsioning of PT Chamber size 220x170x96 mm withprovision of two cable entry all copmlete as per direction of EIC. |
| 165 | Supplying, Installation & Commissioning of PLC panel made out of 2mm CR sheet of size 800mmx 800mmx 2100mm floor mounted powder coated 7 tank process with following components i.e CPU should have 1 MB program memory with extended memory slut Redundant 24 VDC , SMPS 10Amp along with 24V DC SPD IO count as DI 24 , DO-20 , AI-20, AO- 08 & MODBUS-10 sub system shall be same series as CPU ,10 inch panel mounted HMI , modem shoud have support MQTT Protocol by default, 24Volt DC industrial switch with minimum 6 earthmate , 4 SFP port each AI shall be equipped with suitable signal isolator of 20 nos & surge protection device 20 nos LIU isolator , 230Volt AC /230volt AC Torroidal transformer , 1 KVA 230V AC UPS should have capacity to charge 3 nos 12 VDC 65AH battery bank, DP MCB of adequate current capacity, LED tube light 10 inch 5 watt , Door limit switch fan 6 inch with louvers , 4 sqmm straight through terminal and fuse terminal 90 nos earthing plate . (Make:- Siemens,Schnider,ABB,Mitsubishi/Equivalent make with approval of authority) including cost of material with all taxes , transportation to site /storage with insurance. (with both side door) |
| 166 | Supply,Installation & Commissioning of SCADA software (Make-Schiender/Simens/Rockwell/Equivalent make with approval of authority)with Graphical processor visualisation Advanced alaram management,historical and Real time trending,Built-in-reporting,Stastical process control,Multithreaded citect VBA and Cicode programming language with 500 Tag SCADA Software (Make- Schneider, Siemens),1KVa online Ups with 30Min batery backup- 1Each,CPU Having Preloaded win-10 Proffessional, I3-10gen 2.4 Ghz Prrocessor, DDR4 8gb Ram, 500 gb 7200 Rpm HDD-1 Each ( Make- HP,DELL,LENOVO),USB based keyboard - 1Each,USB based Optical Mouse- 1Each,43'' LED monitor - 1Each,A4 size laserPrinter - 1Each,Wooden Computer table - 1 Each ,Preparation of P&I diagram, Creation of Multi visualization screen for Process control,alarm managenent, Historical and realtime process trend, Daily reporting etc complete as per requirement & direction of Engineer - in - Charge (Including license key) |
| 167 | Supply and Installation of pre-fabricated GRP Joint Box with Iid size 600 x 600 x 600 mm for OFC loop and termination as per telecom specification and directions of Site Engineer / Engineer-in Charge. |
| 168 | Integration of instrument like flow meter,control valve,level transducer & pressure transducer etc. |
| 169 | Supply and Laying of 40MM dia HDPE pipe in cable trench as per specification and directions of Site Engineer / Engineer-in-Charge. |
| 170 | Supplying all material, labour, T & P for laying different types of cables for fcv, fm, ducting pipe automation work and S for fitting of PLC panel with following data/ power cables of Lap make including jointingsocketing testing & commissioning etc. complete as per specification basing on requirement and direction of Engineer in charge.as per electrical specification.(Make of wire:-Finolex/Lauritz Knudsen /Anchor/ Havells /V Guard/Equivalent make with approval of the authority) |
| 171 | 4corex1.5 Sqmm copper armoured cable |
| 172 | 2corex1.5 Sqmm copper armoured cable |
| 173 | 6corex1.5 Sqmm copper armoured cable |
| 174 | Design, engineering, procurement of materials and bought out components, manufacturing, assembly at shop, inspection, testing and painting at manufactures works, packing, supply, unloading/ transportation/ handling/ storage at site, assembly at site, installation including touch-up painting, hook-up, pre-commissioning, commissioning, inspection and testing of the complete of the following capacity (prime power) DG sets along with AMF panels. Acoustic enclosure, supply of all erection & commissioning spares, special tools and tackles (as required), instrumentation, all auxiliaries, Exhaust system & silencer, Fuel tank, Fuel piping etc all complete including RCC foundation,sheet Shed with column pipe,Chemical earthing 4 nos,Al power cable of required length,trial run with required amount of diesel as per directrion of EIC in complience with CPCB IV norms.(Make:- Mahindra Power/ Kirloskar/Ashok Leyland/Sterling/Jackson/ Cumin Powers/ Greaves Cotton/ Greaves/TMTL/Captiva/Equivalent make with approval of the authority) |
| 175 | 250 KVA DG Set Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedCorrigendum-1 Issued
Clarifications on tender conditions and amendments issued.
Upcoming · 7 daysBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 7 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 9 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender