Tender For Provision Of Lighting Arrangement At Dda Community Centre A Block In Shalimar Bagh Under Keshav Puram Zone
Tender Value
4.49 Lakhs
Estimated cost
Bid Submission
22 Oct 2026
5 days left
EMD
9000
Bank guarantee accepted
Document Fee
590
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Delhi → Delhi
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Provision Of Lighting Arrangement At Dda Community Centre A Block In Shalimar Bagh Under Keshav Puram Zone
BOQ
| Sl. No. | Item Description |
| 1 | Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure withcover plate having locking arrangement and watering pipe etc.(but without charcoal/ coke and salt ) as required. |
| 2 | Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required. |
| 3 | Laying of one number PVC insulated and PVC sheathed / XLPEpower cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required. Upto 35 Sq mm |
| 4 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing masonry open duct as required Upto 35 Sq mm |
| 5 | Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting,jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required. 63 mm dia (OD-63 mm & ID-51 mm nominal) |
| 6 | Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. in the existing trench, complete as required. 63 mm dia (OD-63 mm & ID-51 mm nominal) |
| 7 | Providing and laying of HDPE PIPE of 40 mm outer dia with PN 4 rating by Hand moling/ Manual Method confirming to IS 4984 592 |
| 8 | Supply of XLPE insulated PVC sheathed AL. conductor armoured Cable 1.1 KV grade conforming to IS-7098 of following size- (a) 2X6 Sq mm |
| 9 | Excavation of the trenches in hard rock soil not exceing 1.5 mtr width and lift upto 1.5 mtr including getting out the excavated soil and disposal of excavated soil as directed within a lead of 50 mtr |
| 10 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 11 | Supplying, installation, Testing & Commissioning of 45 watt Street light LED fixture powder coated pressure die cast aluminum body with driver as per the requirement with Driver efficiency >85%, Input voltage: 140-270 Volt AC, freq 50/60 hz, Operating temp range -15 deg to 50 deg centigrade, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2 , P. F.≥0.95, IP 66,IK-10, CRI >80, under voltage and over voltage protection, EMI EMC As per CISPR -15, lenses for beam angle as per IESNA type I/II/III as per the width of the road and the project requirement., suitable to fit in up to 65mm dia pipe, life time (LED,Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin),SDCM(Standard Deviation Color Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy >_135 lm/Watt output . LM79 & LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminum housing such that LED junction temperature shall not rise 90\\"C |
| 12 | Fabrication , supplying and fixing class B galvanised single overhang arm bracket made out of 250 mm long galvanised top tube with cap and 250 mm long 32 mm dia galvanised pipe with tightening bolts complete as required |
| 13 | Fabrication , supplying and fixing class B galvanised double overhang arm bracket made out of 250 mm long galvanised top tube with cap and 250 mm long 32 mm dia galvanised pipe with tightening bolts complete as required |
| 14 | Supply of PVC insulated and FR PVC sheathed multicore copper conductor 1.1. kv grade conforming to IS694 as reqd:-3x1.5 sqmm |
| 15 | Fabrication, supply & erection of 5.0 mtr height ,minimum 3mm thick , bottom dia of 130mm, & top dia of 70 mm base plate of size 225X225X12mm thick size flange mounted hot dip galvanized octagonal pole made from HT steel plate window with flash cover with full vertical window cover at appropriate height form the base plate on existing cement concrete predestal as required i/c supplying and fixing of 6 mm thick laminated mounted sheet inside the window and i/c providing and welding 3 nos. GI strips 4mm thick of suitable length and having suitable size tapped holes as reqd. terminal block suitable for 25 sq mm conductor - 4 nos. & shorting links on DIN channel i/c providing and fixing DIN channel of suitable length ,6 Amp SPMCB 'C' curve characherstics earth stud cable support clamp suitable for upto 4X25 sq mm cable Logo/Name of manfucturer shall be either embossed or rivited plate on the pole Galvanization as per relevant IS code etc as required. |
| 16 | Providing and laying in position M25 grade reinforced cement concrete foundation of size 450mm(L)X450mm wide and 1000 mm deep i/c excavation of earth providing cutting bending and placing in position reinforcement of cold twisted bars of 12 mm dia- 960mm long (approx) 8 nos. and reinforcement of cold twisted bars of 12 mm dia - 960 mm long (approx) -8 nos and reinforcement of cold twisted bars of 8 mm dia -1400 mm ( approx) -6 nos.(with 150 mm spacing ) as required with supplying and position of 4 nos. foundation bolts 16 mm dia, 600 mm long J type i/c 2 nos template anchor plates of size 225mm x3 mm and providing DWC HDPE for cable entry and exit as required for 3 m to 5mtr pole. |
| 17 | Supplying and erection of 75 mm X 90 mm shackle insulator with G. I. Bolt, nuts and straps etc. as required . |
| 18 | Providing and fixing of Stainless steel name plate of size 6×8 sq inch made of 20 gauge sheet including engraved name of area representative duly painted along with SS clamp nut bolt etc as required |
| 19 | P/F Name board made of MS Sheet 90X60 Cm, 1 mm thick with frame of MS angle 50X50X6 mm , two diagonal braces at the back of sheet of Ms Flat 40X6 mm total height of the bpard above ground level 2.40 M Length of Leg Below ground 0.30 M embeded in CC Block 1:2:4( 1 cement , 2 Coarse Sand , 4 Graded stone aggregate 40 mm nominal size)30X30X45 cm including excavation and removal of surplus earth with in 50 m lead applying priming coat of approved steel primer painting with synthetic enamel paint of approved quality and lattering with enamel paint of approved colour ( one side as per drawing/ direction of engineer in charge Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Oct 14, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedOct 22, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 5 daysOct 22, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 5 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender