Defence Statutory Bodies & Commissions/Committees Closing in 8 days TDR #58032278

Tender For Provisioning Of Security Fencing Along With Main Gate For 7.5 And 5 Meter Vsat Antenna Of Css And Nc3 I Network And Provn Of Epoxy Flooring Building No P-106 (Sakti) Under Ge Haddo, Sri Vijaya Puram

Issued by Statutory Bodies & Commissions/Committees · South Andamans, Andaman And Nicobar Islands
Tender Value
49.50 Lakhs
Estimated cost
Bid Submission
03 Nov 2026
8 days left
EMD
99000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
South Andamans → Andaman And Nicobar Islands
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Provisioning Of Security Fencing Along With Main Gate For 7.5 And 5 Meter Vsat Antenna Of Css And Nc3 I Network And Provn Of Epoxy Flooring Building No P-106 (Sakti) Under Ge Haddo, Sri Vijaya Puram

Corrigendum

Sr No Corrigendum Date Corrigendum Type New Submission Date
1 23-Oct-2026 BOQ Corrigendum BOQ 03-Nov-2026

BOQ

Name of Work:- PROVISIONING OF SECURITY FENCING ALONG WITH MAIN GATE FOR 7.5 AND 5 METER VSAT ANTENNA OF CSS AND NC3 I NETWORK AND PROVN OF EPOXY FLOORING BUILDING NO P-106 (SAKTI) UNDER GE HADDO, SRI VIJAYA PURAM
Sl. No. Item Description
1M&L for preparation of existing concrete flooring by mechanically grinding the surface using suitable mechanical floor grinder, removing laitance, loose particles, stains and other surface contaminants, followed by thorough vacuum cleaning and preparation of the substrate, and carrying out the following treatment/operations, complete all as specified and as per manufacturer's instructions and specification:(a) Providing and applying approved epoxy primer coat over the prepared concrete substrate at the manufacturer's recommended coverage and thickness, including mixing and application complete.(b) Providing and applying 4 mm thick epoxy underlay screed of approved make over the primed surface, including preparation, mixing, laying, levelling and finishing to the required thickness, complete as per manufacturer's specification.(c) Providing and applying 2 mm thick epoxy self-levelling flooring system over the cured underlay screed, including mixing, laying and spreading uniformly to the required thickness, complete as per manufacturer's specification.(d) Immediately after application of the self-levelling epoxy layer, applying suitable spike roller uniformly over the surface to release entrapped air and obtain a smooth, uniform and pinhole-free finish, followed by allowing the flooring system to cure/dry for the period recommended by the manufacturer, complete.NOTE:Makes of flooring materials shall be SIKA India Pvt Ltd / Bostik India Pvt Ltd / Fosroc Chemicals / STP Ltd / Asian Paints Ltd,The complete EPU flooring system shall be executed strictly as a system of one approved manufacturer, with primer, underlay screed and self-levelling components being compatible with each other and used in accordance with the manufacturer's written recommendations.EPU flooring shall be carried out only by an authorised/trained applicator of the approved manufacturer. The contractor shall submit documentary proof/details of the authorised applicator to the GE for approval. The work shall not commence until the applicator has been approved by the GE.The contractor shall submit the manufacturer's technical data sheet, application procedure, recommended coverage/consumption, curing time and system warranty, wherever applicable, to the GE before commencement of work.The rate shall include all materials, labour, mechanical grinding, surface preparation, cleaning, primer, epoxy underlay screed, self-levelling epoxy, spike rolling, tools, tackles, protective measures, curing and all incidental operations necessary to complete the flooring in all respects.Thickness of the completed flooring system shall be approximately 6 mm excluding primer, comprising 4 mm epoxy underlay screed + 2 mm epoxy self-levelling layer, unless otherwise specified by the approved manufacturer's system.
2M&L for machine cut kota stone slab flooring 20-25mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete over 15mm thick screed bed in cement mortar 1:4 including rubbing and polishing etc, complete all as specified and directed.
3M&L for machine cut kota stone slab 20-25mm thick in riser of steps, skirting, dado and pillar laid over cement screed and jointed including bull nosing the edges, rubbing and polishing complete including 10mm thick backing coat in CM 1:4 etc all as specified and directed.
4Providing and laying 60mm thick factory made chamfered edge cement concrete paver block of M-35 grade with approved colour, design & pattern as in footparth, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size/shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of fine sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand etc, completed all as specified and directed.
5Excavation in trenches for foundation n.exc 1.5 meter wide and n exc. 1.5 meter depth and not exc. 10 sqm on plan and getting out in soft/loose soil complete all as specified and directed.
6Returning, filling in approved earth including spreading, levelling watering and well ramming in layers n.exc 25cm in foundation in hard/dense soil complete all as specified and directed.
7Removing excavated material soil n.exc 50 m and depositing where directed at a level n.exc 1.5 mm above the starting point complete all as specified and directed.
8Excavating in post holes each n exc 0.5 cum, getting out, in soft /loose soil, ramming earth filling or borken rubble mixed with earth around in layers nexc 25 cm watering and removing ssurfaces soil to distance nexc 50 m and making good surfaces all as specified and directed.
9M&L cement concrete 1:4:8 type D2(Using 40mm graded stone aggregate) as in foundation filling and mass concrete complete all as specified.
10M&L PCC 1:2:4 type B2 (using 40mm graded agg) as in foundation filling and mass concrete etc complete all as spd and directed.
11Material and labour for providing Plain Cement Concrete (1:2:4) type B1 using 20 mm graded aggregate as in lintels upto 1.5 m clear span, cills, steps, seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, coping, kneelers, apex stones etc water troughs and the like including weathering, slightly rounded or chamfered angles and throating, including necessary form work etc, complete all as specified and directed.
12M&L for pre-cast cement concrete solid block masonry, exc 10cm width, blocks cast in PCC 1:3:6 type C1, using 20mm graded stone aggregate, set in CM 1:6 complete all as specified and directed.
13M&L for rolled mild steel posts and struts in fencing and similar work conforming to Fe-290 Gde E-165 including cutting tops to shape as directed, drilling holes, notching for wire, etc. flat iron fillets for securing wire mesh etc, complete all as specified and directed.
14Supply and fix roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc. Fe 410 -W (Gde E- 250) quality A etc, complete all as specified and as directed.
15Material & Labour for providing and fixing stainless steel (Grade 304) railing made of hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (where ever required) and fitting the same with necessary stainless steel nuts and bolts complete, including fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of floor or the side of waist slab with suitable arrangement, etc all as specified and directed.
16S&F for MS Galvanised with 1.00 mm thick PVC coated chain link fencing 50mm x 50mm over 3.15 mm GI wire including fixed to any type of fencing posts with straining bolts, stiffener rods etc including provision of binding wire if required complete all as specified and as directed.
17S & F for Galvanised. 2 strand, steel barbed wire 2.24mm dia barbed with 2mm dia barbs at 75mm spacings and straining and fixing to any type of standard rails straining bolts, including, securing or tying at crossings with and provision of galvanised mild steel wire, staples or steel pins, etc. as directed (each line wire to be measured),etc complete all as spd and directed.
18S&F 600mm dia concertina coil fencing conforming to IS 4454 Part-I, made out of 2.6mm (+ or - 2%) dia of steel core wire galvanised and with anti rust coating (Black colour), with coils not less than 51 turns for an effective stretched length of 6m with 2 handles, duly placed on existing supports over security/ compound walls and tied with 2mm dia binding wire and the spikes at the ends of coils embedded into PCC coping all as specified and as directed. Note: PCC coping shall be measured and paid separately.
19Providing and fixing PVC lattice privacy screen paneling made of rigid HDPE lattice sheets of approved make and colour such as White / Off White / Green / Grey / Black / Ivory, having minimum thickness 7- 8 mm, in diamond (diagonal) or square lattice pattern with opening size approximately 27 mm × 27 mm, in standard sheet size 1219 mm × 2438 mm (4’ × 8’) or 2410 mm × 1205 mm, cut to required size and fixed in position for use in balcony railing, garden screen, partition, or privacy screen. The panels shall be UV stabilized, weather resistant, termite proof, moisture resistant and corrosion free, providing approximately 50% to 78% privacy blockage while allowing ventilation and light, all complete as per approved design, drawing and direction of Engineer-in-Charge.
20Material and labour for Mild steel TMT bars of Fe 500 or Fe 500D, 10 mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.90 mm dia or securing with clips complete all as specified.
21Material and labour for Mild steel TMT bars of Fe 500 or Fe 500D, 8 mm dia and over upto and including 10 mm dia in stirrups, spacers and binders, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.90 mm dia or securing with clips complete all as specified.
22M&L for Reinforced cement concrete Type B1,1:2:4 using 20mm graded stone aggregate in Foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc all as specified and directed.
23M&L for Reinforced cement concrete Type B1,1:2:4 using 20mm graded stone aggregate in Columns, pillars, piers, posts and struts all as specified and directed.
24M&L for use of Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, and similar works for rough finished flat concrete surfaces all as specified and directed.
25M&L for use of Formwork to sides of pillars, posts, struts, piers, columns and stanchions, and similar works for rough finished flat concrete surfaces all as specified and directed.
26M&L 15mm thick rendering on fair faces of brick work or concrete surfaces and finished even and fair without using extra cement in CM 1:4 etc, complete all as specified and directed.
27M&L for applying two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces etc, all as specified and directed
28M&L for two coats synthetic enamel paint over a coat of red oxide on new iron surfaces of any description not otherwise described over 10 cm including preparation of new or previously untreated surface complete all as specified and directed.
29Supply and laying Cable in trenches / wall / Pole / PCC XLPE, insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor of size 4 core 10 Sqmm complete all as specified and directed.
30Supply, Install and erect steel tubular swaged pole type 410 SP-31 of 9.0 mtrs long complete with cast iron base plate finial taper plug, pole cap, bolts, nuts and washers pole made out of MS tubing confirming to IS-2713 Part-II, including drilling of holes painting with two coats of bituminous paint internally and externally embedded portion upto ground level ground/concrete and painting to exposed surfaces with two coats aluminium paint and one coat of red oxide primer complete all as specified and directed.Note :- Excavation/Earth work in any type of soil/ strata PCC foundation, coping of poles, cross arms, clamps shall be measured and paid separately.Make :- M/s Bombay Tubes/ M/s Jindal Steel Products/ M/s India Tubes Co/ M/s Bharat poles/ National Tubing / Utkrarsh India Ltd
31Supply and laying in trenches or in cable ducts or clamping on wall DWC HDPE pipe of size 50 mm (OD) x 38 mm (ID) along with connected accessories like couplers. bends, end caps etc. for LT cable protection complete all as specified and directed by Engr In Charge.
32Excavation in trenches not exceeding 1.5 m in wide and not exceeding 1.5m in depth for laying of cables / pole and getting out in the hard/dense soil complete all as specified and as directed.
33Excavation in trenches not exceeding 1.5 m wide and exceeding 1.5 m but not exceeding 3.0 m depth for laying of pipes/cables/erection of poles etc. and getting out in hard/dense soil complete all as specified and directed.
34M&L for PCC 1:3:6 type C1 using 20mm graded aggregate as in coping/pedestals of poles including necessary form work complete and applying two coats of white wash to exposed surface of coping/platform complete all as specified and directed.
35M & L for Cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of pain
36Supply and fix LED flood light 200 watts made up of pressure die cast aluminum housing with toughened glass and high power LEDs and secondary lenses with IP 66 protection,efficacy 110/120 PW 10 KV inlcluding driver suitable for working on 230 Volts single phase 50 Hz supply with all accessories complete all as specified and directed by Engineer-in-charge
37Supply and fix thermoplastic outdoor cable junction box hinged/screwed door type of size 280x170x130 mm fixed embedded in pcc foundaton for bollard for 3 phase and neutral incoming cable, 3 phase and neutral outgoing cable with terminals and single Phase & neutral connection for light fitting, 4 pole, 415 Volt and one MCB SP 6 Amp, 240 Volt and clamp system (screw less), shock proof safe IP-55, weather proof, rust, dust and water proof internally embedded gasket with provision metric knockouts for cable entry through gland suitable for 10 sqmm to 25 sqmm cable as required at site complete all as specified & directed.
38Supply and connect PVC insulated PVC Sheathed flat twin core cable with stranded aluminium conductor of size 2.5 sqmm including taking down existing unserviceable wire complete all as specified and directed by Engineer-in-charge
39Supply, installation, commissioning and testing of powder coated factory made out door type double door Feeder pillar box confirming to IP 54 protecttion, of suitable size made of Robust steel sheet construction made from min 3.15 mm steel sheet with countersunk holes at bottom for base mounting brackets and sheet steel gland plates for cable entry, formed gasket arround doors, with provision of Lock inserts, earthing straps, door stay and grouted in ground by using angle iron frame of size 40mm x 40mm x 6mm, pedastal type and provided with four nos of angle iron supports duly embedded in foundation using PCC (1:2:4) type C-1 with 20mm graded stone aggregate.The panel will be prewired with suitable size PVC insulated copper conductor cable, multistranded housed with the following accessories:- (a) Al bus bar of suitable capacity for phase and neutral. (b) MCCB 4P 63 Amp, 415 Volts 16KA – 01 No (incoming)Outgoing :(c) 25 amps weather proof 3 pin Switch Socket combination with MCB SP 25 amps-02 Nos(d) Indicating lamps (set 03 Nos) - 01 set (R,Y & B)
40M & L earthing complete with galvanised steel earth plate electrode 60cm x 60cm x 6mm thick buried directly in ground earth pit not less than 2.25 mtr deep below normal ground level) with top edge of plate not less than 1.5m below ground level, connecting to the Galvanised iron earth strip 25x4mm dia, by means of nuts, bolts, check nuts and washer etc of galvanised iron and earth lead protected by provision of GI pipe medium grade 40mm bore from earth elelctrode to test point incl provn of concrete pit in PCC (1:2:4) type B-1 using 20mm graded stone agagregates with 40mm thick cover of RCC (1:2:4) reinforced with XPM sheet (weight not less than 4Kg/Sqm) and frame of angle iron 25 x 25 x 6mm with lugs 2 Nos and with 8mm dia MS bar handle made to shape, GI pipe medium grade 20mm bore pipe for watering perforated at bottom 1.75 mtr long placed on top edge of earth plate, common salt and charcoal filling test point with fixing arrangement, funnel, wire mesh and earth work in hard/dense soil, returning in and removal of surplus soil to a distance not exceeding 50mtr, complete all as specified in electrical plate No 3 of SSR Part I and connection to earth test point including testing on completion all as directed. Note:- Item of earthing includes cost of 7.5m long galvanised iron earth strip of 25x4 mm size and protection pipe of 40mm bore GI medium grade. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 58032278
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 49.50 Lakhs
LAST DATE 03-11-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Provisioning Of Security Fencing Along With Main Gate For 7.5 And 5 Meter Vsat Antenna Of Css And Nc3 I Network And Provn Of Epoxy Flooring Building No P-106 (Sakti) Under Ge Haddo, Sri Vijaya Puram
Basic Detail
Tender No 8400/E8
Bidding Type Tender
Location
City South Andamans
State Andaman And Nicobar Islands
Key Dates
Publish Date 23 Oct 2026
Submission Date 03 Nov 2026
Open Date 01 Jan 0001
Finance
Tender Value 49.50 Lakhs
Tender Fee 500
EMD 99000
Exemption Available
Document List
30ace0fa-8217-4bf9-9591-b3668ab5f865.html
8400Tender.pdf
BOQ_890346.xls
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Oct 23, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Nov 03, 2026
18:00 IST

Corrigendum-1 Issued

Clarifications on tender conditions and amendments issued.

Upcoming · 8 days
Nov 03, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 8 days

Tender Documents

Download All (ZIP) ↓
html

30ace0fa-8217-4bf9-9591-b3668ab5f865.html

pdf

8400Tender.pdf

xls

BOQ_890346.xls

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender