Housing Urban and Rular Development Government Departments Closing in 16 days TDR #58032091

Tender For Upgradation Of Security Lights Around Boundary Wall With Control Panel At Civil Secretariat Srinagar.

Issued by Government Departments · Srinagar, Jammu and Kashmir
Tender Value
4.98 Lakhs
Estimated cost
Bid Submission
04 Nov 2026
16 days left
EMD
9960
Bank guarantee accepted
Document Fee
200
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Srinagar → Jammu and Kashmir
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Upgradation Of Security Lights Around Boundary Wall With Control Panel At Civil Secretariat Srinagar.

BOQ

Name of Work:- Upgradation of Security lights around boundary wall with Control Panel at Civil Secretariat Srinagar.
Sl. No. Item Description
1Supply/Fixing/Testing and Commissioning of 6Amp to 32 Amp Rating SP,240 volt C Curve 10K, Miniature Circuit Breaker suitable for inductive load of following poles in existing MCB . DB Complete with connections.(L&T / Siemens / Legrand / Schneider / Eton / eqv Make)
2Supply/Fixing/Testing and Commissioning of following rating, Double pole, (P+N) 240 V, C* Curve 10K,Miniature Circuit Breaker (MCB) in the existing MCB DB complete with connections. (L&T/Siemens /Legrand/Schneider Make)
332 Amp
440Amp.
563Amp.
6Supply/Installation/Testing and Commissioning of CPRI Approved (IS/IEC:61439) Main Controlling Panel,fabricated out of heavy gauge sheet steel ,dully Painted with powder coated paint ,dust protected ,earth terminal fitted on epoxy cleats, volt meter & Ammeters with selector switch & CT Coil of required ratio with all necessary connections & inner wiring of panel on both heating and lighting circuits. The switches are connected with bus bars inside panel & manufacturer CPRI Certified.The switch are adjustable type made of Havells/ L&T/ABB/Legrand/Siemens Make and change over switch should be of Havells/ L&T/Legrand/ Schneider Make.(1) Normal Incomer:a) 125 Amp-4-Pole ,15kA C-CURVE MCCB with extended terminals Havells/L&T/Legrand/Schneider Make as approved=01 No. b) 200 Amps TPN Al. Bus Bar Set = 01 Set,Digital Voltmeter ,Ammeter ,C.T Coils with Selector Switch & Phase indicator Set.Outgoing:(1) Normal outgoing for Heating/AC/Lighting/Inverter etc load(a) 63-Amp DP MCB = 04 No. (b) 40-Amp DP MCB= 04 No. (c) 32-Amp DP MCB = 04 No.
7Supply/Laying/Connecting and Commissioning of 40 sq.mm 3.5-Core XLPE/PVC insulated and steel armored 1.1 KV grade Aluminum Cable of Havells/RR Make with required size of thimbles dully crimped with hydraulic crimping tool including Providing/Fixing of saddles/clips with making of connection and partially to be laid underground through DWC High Density Poly ethylene Pipe having Corrugation on Outer wall and Plain surface inner wall Conforming to IS: 14930 Part-1 and 2 Complete with accessories for Protection of 1.1 KV Grade under Ground cable Directly in Ground at a Depth of 50 CM including excavation and Refilling the Trench
8Maintenance Free copper rod earthing system with soil treatment to improve the Pit resistance Value.Supply,Installation and Testing of 75 mm copper Pipe Filled with Crystalline conductive Mixture with Eco friendly GEM backfill Compound 2No. Bags also having Earth pit chamber (300mm x 300mm) with man- hole cover for the above. Including cost of 20mm Wide copper strip as required in one run fitted with of brass nut bolt & spring washer from earthing rod up to main Control panel through suitable DWC High Density Poly ethylene Pipe having Corrugation complete job.
9Supply/Laying of 25/32/38mm Dia and 2mm thick PVC Conduit/Lockable Channel of Anchor/Ravindra Blue/Finolex Make with other accessories like bends,etc complete to be laid in wall for downs and finishing the surface to its original shape by cement mortar plastering/Wall Putty/Paint etc.
10Supply/Installation/Testing and Commissioning of 3-Phase, Four Pole 100 Amp,415V Ac,50Hz offload Manual Changeover Switch side handle in enclosure Havells/L &T/ABB Make including S/F/Crimping of Suitable Size of thimbles for connections as per site requirement
11Supply and fixing of Hylum sheet (phenolic laminated sheet), 3 mm / 6 mm / 10 mm thick (as specified), duly cut to required size and shape, fixed with necessary nuts, bolts, screws, washers, spacers etc., including finishing and making good the surface, complete as required
12SITC Of ST Pole 7 mtr long [410-SP-33]alongwith top arm for 2 no LED Fittings,Cement bottoming in 1;2:3 mix ,painting &earthing
13Providing & Fixing of IK08 IP-66 protected high power LED 50 Watt flood light system with single piece Pressure diecast aluminium housing, toughened glass diffuser with suitable lenses on LED to achieve various beam angles, of high power LED of 3 to 5 watt each. Integrated potted driver as a unique BIS R number having efficiency more than 85% and in compliance to BIS certified and Trade mark certificate. The System level Luminaire efficacy >=125 Im/wt. LED driver Input Voltage AC 120 to 270 V AC with High voltage Cutoff @>=300 V AC and Auto resetting Safety .Power Factor >0.95 , THD(I) <10% , driver current <=750mA. driver should be Phase to phase protection of 440 V for 4 Hrs. Electrical Connector, Surge Protection Min >=4KV internal and 10KV external but inside driver compartment, System life of 50000 Burning hours with 70% of Initial Lumens maintained, CRI>70 and CCT 5700K 355K. Manufactures Word Mark/Name Engraved/Embossing/Screen printing on die cast housing to allow traceability/authenticity. Fixture shall be IS 10322 Complianced.OEM Must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79/LM80) Certificate/ report with liable warranty of product/accessories from OEM shall be submitted. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR:-High Power LED Flood Light Minimum lumen output 6200 Im of Havells/Crompton/Philips/Halonix/Equivalent Make as approved and to be installed on outside block including S/F of suitable size of Gyser bolt.The job further includes replacement warranty of fixture (if damaged/burnt out what so ever reason) for a period of two years reckoned from date of successful commissioning
14Supply/Installation/Testing and Commissioning of 3-Phase, Four Pole 200 Amp,415V Ac,50Hz 36KA S/F/Crimping of Suitable Size of thimbles for connections as per site requirement
15Supply/laying/Testing and Commissioning of 10mm sq single core FRLS PVC insulated duly Crimped by way of Suitable Size of thimbles for connections as per site requirement
16Supply/laying/Testing and Commissioning of 16mm sq single core FRLS PVC insulated duly Crimped by way of Suitable Size of thimbles for connections as per site requirement Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 58032091
AUTHORITY Government Departments
TENDER VALUE 4.98 Lakhs
LAST DATE 04-11-2026
Authority
Authority Name Public Works Department
Work Description Tender for Upgradation Of Security Lights Around Boundary Wall With Control Panel At Civil Secretariat Srinagar.
Basic Detail
Tender No e-NIT No. 23-P of 10/2026 Dated- 14-10-2026
Bidding Type Tender
Location
City Srinagar
State Jammu and Kashmir
Key Dates
Publish Date 14 Oct 2026
Submission Date 04 Nov 2026
Open Date 05 Nov 2026
Finance
Tender Value 4.98 Lakhs
Tender Fee 200
EMD 9960
Exemption Not Available
Document List
a46a4f32-0cc1-42d8-ac18-16cd79a9ae38.html
BOQ_1110806.xls
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Oct 14, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Nov 04, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 16 days
Nov 05, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 17 days

Tender Documents

Download All (ZIP) ↓
html

a46a4f32-0cc1-42d8-ac18-16cd79a9ae38.html

xls

BOQ_1110806.xls

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender